ES-709DCDA For Non-Health Hazard Applications Job Name ––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location ––––––––––––––––––––––––––––––––––––––––– Approval Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––––––– –––––––––––––––––––––––––––––––––––––––– Series 709DCDA Double Check Detector Assemblies Sizes: 3" – 10" (80 – 250mm) Series 709DCDA Double Check Detector Assemblies are designed exclusively for use in accordance with water authority containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e. glycerin wetting agents, stagnant water and water of non-potable quality from being pumped or siphoned into the potable water line. Benefits: Detects leaks . . . with emphasis on the cost of unaccountable water; incorporates a meter which allows the water utility to: 709DCDAOSY • detect leaks underground that historically create great annual cost due to waste. • provide a detection point for unauthorized use. It can help locate illegal taps. Check Assembly Module Test Cock Cover Modular check design concept facilitates maintenance and assembly access. All sizes are standardly equipped with resilient seated OSY shutoff valves, 5⁄8" x 3⁄4" (16 x 19mm) meter and ball type test cocks. Features • Body construction fused epoxy coated cast iron • Replaceable bronze seats Seat Disc • Maximum flow at low pressure drop • Compact for economy combined with performance • Design simplicity for easy maintenance • Furnished with 5⁄8" x 3⁄4" (16 x 19mm) bronze meter • No special tools required for servicing Check Assembly Module Features a modular design concept which facilitates complete maintenance and assembly by retaining the spring load. First and second check valve spring modules are not interchangeable. Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a potable water supply. Degree of hazard present is determined by the local authority having jurisdiction. The unit shall be a complete assembly including UL listed resilient seated OSY shutoff valves and test cocks. The unit shall be UL/FM approved with UL/FM approved OSY shutoff valves. The auxiliary line shall consist of an approved backflow preventer and water meter. The assembly shall meet the basic requirements of ASSE 1048; AWWA Std. C510 for Double Check Valves. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be a Watts Regulator Company Series 709DCDA. Now Available WattsBox Insulated Enclosures. For more information, send for literature ES-WB. IMPORTANT: INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Pressure – Temperature Materials Body: Epoxy coated cast iron Seat: Bronze Temperature Range: 33˚F – 110˚F ( 0.5˚ – 43˚C) continuous, 140˚F (60˚C) intermittent Disc Holder: Bronze Maximum Working Pressure: 175psi (12.1bar) Trim: Stainless steel Standards Check Valve Discs: Rubber Test Cocks: AWWA Standard C510 Bronze Approvals Models Suffix: OSY - UL/FM outside stem and yoke resilient seated gate valves B.64 1048 LF - 4" – 10" (100 – 250mm) without shutoff valves Approved by the foundation for Cross-Connection Controland Hydraulic Research at the University of Southern California. Sizes 4" – 10" (100 – 250mm) approved for horizontal and vertical “flow up”. Size 3" (76mm) approved for horizontal only. Dimensions – Weights Factory Mutual approved 4" – 10" (100-250mm) vertical “flow up”. CFM - cubic feet per minute meter GPM - gallons per minute meter U* C (open) D E L R T A SIZE (DN) DIMENSIONS A D C E WEIGHT L R T U* In. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm 3 4 6 8 10 80 100 150 200 250 40 52 621⁄2 75 90 1016 1321 1588 1905 2286 187⁄8 223⁄4 301⁄8 373⁄4 453⁄4 479 578 765 959 1162 31⁄2 33⁄4 41⁄2 51⁄2 61⁄2 89 95 114 140 165 12 17 21 26 32 305 432 533 660 813 24 34 411⁄2 52 64 610 864 1054 1321 1626 14 15 16 17 18 356 381 406 432 457 3 6 71⁄2 9 101⁄4 76 152 191 229 260 14 14 16 21 25 356 356 406 533 635 * Service clearance for check assembly from center. †UL/FM approved backflow preventers must include UL/FM approved OSY. W/OSY† gates lbs. kgs. 190 403 727 1327 2093 86 183 330 602 949 Capacity *Typical maximum system flow rate (7.5 ft./Sec.) **UL rated flow 3" (80mm) 8" (200mm) ** 96 14 kPa psi ** Pressure Drop Pressure Drop kPa psi 69 10 41 6 14 2 0 0 0 0 100 380 200 760 5 1.5 300 1140 400 1520 7.5 2.3 15 4.6 96 14 41 6 14 2 0 0 gpm lpm fps mps 0 0 400 1520 800 3040 5 1.5 Pressure Drop 96 14 6 14 2 0 0 0 0 100 380 200 760 5 1.5 kPa psi ** 300 1140 7.5 2.3 400 1520 500 1900 15 4.6 600 2280 gpm lpm fps mps 6" (150mm) ** Pressure Drop 96 14 ** 69 10 41 6 14 2 0 0 0 0 200 760 400 1520 5 1.5 600 2280 800 3040 7.5 2.3 Flow ** 96 14 2000 7600 15 4.6 4000 gpm 15200 lpm fps mps 1000 3800 1200 4500 1400 5320 15 4.6 gpm lpm fps mps ** 69 10 41 6 14 2 0 0 0 0 400 1520 800 3040 1200 4560 5 1.5 1600 6080 2000 7600 7.5 2.3 Flow Flow kPa psi 1600 6080 10" (250mm) 4" (100mm) 69 10 41 1200 456 7.5 2.3 Flow Pressure Drop ** ** 69 10 Flow kPa psi ** 2400 9120 2800 10,640 3200 3600 4000 12,160 13,680 15200 15 4.6 gpm lpm fps mps For additional information, visit our web site at: www.watts.com A Watts Water Technologies Company ES-709DCDA 0638 USA: 815 Chestnut St., No. Andover, MA 01845-6098; www.watts.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca © 2009 Watts