LT 2000 LINE TESTER LEVEL GENERATOR - SELECTIVE LEVEL METER - REFLECTOMETER ALL IN ONE HANDHELD BATTERY-POWERED PACKAGE ! ATEN has developed this easy to operate and cost effective instrument for field operation, to verify the quality of copper pair for analog and digital transmission up to 2 Mbit/s. The LT2000 can perform following measurements: NOISE - LEVEL - ATTENUATION - CROSSTALK - RETURN LOSS for various transmission systems: •Base band •160 Kbit/s •1,5 Mbit/s •2 Mbit/s •HDSL •ADSL APPLICATIONS NOISE & LEVEL METER With one LT2000 at one side of the line. ATTENUATION METER With two LT2000 at the opposite sides of the line. CROSSTALK METER • With one LT2000 at one side of the lines; • With two LT2000 at the opposite sides of the lines. RETURN LOSS METER With one LT2000, to measure the level of echo-signal caused from the impedance mismatching of the line. LONGITUDINAL BALANCE METER With one LT2000 and a special adapter, to measure the balance attenuation of the line referred to ground or other conductor. SPECIAL FEATURES • AUTOMATIC MEASUREMENTS IN SWEEP MODE - RMS Noise level readout on programmed wide-band; - Return loss: frequency & level readout of min. and max. echo level; - Near Cross-talk: frequency & level readout of min. and max. cross level. • INTERCOMM facility between a local and remote user, using the line under test. LT2000 - TECHNICAL CHARACTERISTICS General Case.....................................................: ABS. Connections.........................................: • input connector "RX" triple banana jack (a-b-Gnd); • input/output connector "TRX" triple banana jack (a-b-Gnd); • polarized connector for external supply and batteries charger; • RJ-45/4 connector for headset interface. Display .................................................: alphanumeric LCD - 4 lines x 16 characters. Keypad.................................................: micro-switches under polyester membrane film. Power supply .......................................: • NiMh internal rechargeable batteries (green), ≥ 3 hours of operating time; • external: 11 to 32 Vdc / 1,5 to 0,6 A. Ambient temperature ...........................: operating: 0 ÷ 50° C; storage: -10 ÷ 60° C. Dimensions ..........................................: 100 x 40 x 210 mm. Weight..................................................: < 1 Kg. Level Generator Output impedances..............................: < 10 Ω, 150 Ω (120 or 135 Ω on request), 600Ω balanced (≈ 5µF series). Output frequency bands ......................: 200 Hz ÷ 2 MHz. Resolution............................................: 1 Hz from 200 Hz up to 10 kHz; 100 Hz from 10 kHz up to 2 MHz. Frequency accuracy/stability ...............: ≤ ± 50 ppm. Harmonic distortion .............................: ≤ 0.5 %. Output level..........................................: 0.0 dBm ± 0.2 dB @ 10 kHz. Output Level accuracy vs. frequency (referred to 10 kHz): -2 ÷ -1 dB -1 ÷ -0.5 dB Zo Out 600 Ω Zo Out 120÷150 Ω 200 Hz 300 Hz -0.5 ÷ -0.2 dB ± 0.1 dB ± 0.3 dB 200 Hz 800 Hz 800 kHz 2000 kHz 600 Hz 2 kHz 800 kHz 2000 kHz Selective Level Meter Input impedances ................................: 150 Ω (120 or 135 Ω on request), 600 Ω, ≥ 200 kΩ balanced (≈ 5µF series). Tunable frequencies ............................: tracking with TX frequency (200 Hz ÷ 2 MHz). Resolution............................................: 1 Hz from 200 Hz up to 10 kHz; 100 Hz from 10 kHz up to 2 MHz. Tuning accuracy / stability ...................: ≤ ± 50 ppm. Selectivity (fo ≥ 800 Hz).......................: ≤ -0.5 dB @ ± 30 Hz fo; ≥ -50 dB @ ± 500 Hz fo. Level measurements ...........................: absolute (dBm) and relative (dBr). Input range...........................................: ≤ -100 ÷ +5 dBm / resolution: 0.1 dB. Hybrid circuit - Return Loss .................: ≥ 40 dB with nominal load. Noise floor (TX off)...............................: ≤ -100 dBm @ 600 Ω; ≤ -95 dBm @ 120÷150 Ω. Intrinsic cross talk ................................: ≤ -90 dBm @ 1.000 MHz. : ≥ 60 dB (fo ≥ 800 Hz). Freq. image / spurious rejection Level accuracy vs. input level (referred to 10 kHz): I← - - - - - ± 0.3 dB Zo In 600 Ω Zo In 120÷150 Ω +5 dBm +5 dBm ± 0.2 dB 0 dBm 0 dBm ± 0.5 dB -70 dBm -70 dBm TX OFF ± 1 dB -85 dBm -80 dBm - - - - - →I ± 2 dB -95 dBm -90 dBm -100 dBm -95 dBm Level accuracy vs. frequency (referred to 10 kHz / 0 dBm): -2 ÷ -1 dB -1 ÷ -0.5 dB Zo Out 600 Ω Zo Out 120÷150 Ω 200 Hz 300 Hz -0.5 ÷ -0.2 dB ± 0.1 dB ± 0.3 dB 200 Hz 800 Hz 800 kHz 2000 kHz 600 Hz 2 kHz 800 kHz 2000 kHz Automatic measurements in sweep mode Automatic measurements....................: • Noise (or Level): - frequency & level readout of min. and max. noise level; - RMS noise level readout on programmed wideband; • Return-loss: frequency & level readout of min. and max. echo level; • Near Cross talk: frequency & level readout of min. and max. cross level; Operating programmable bands..........: • “base band” from 200 Hz min. to 10 kHz max. (1 step/sec. speed) (100; 200; 400; 1000 Hz selectable step) • “high band” from 10 kHz min. to 2 MHz max. (0.1; 0.2; 0.4; 1; 2; 4; 10 and 20 kHz selectable step) Sweep generator .................................: • “base band” from 200 Hz min. to 10 kHz max. (10 step/sec. speed) (100; 200; 400; 1000 Hz selectable step) • “high band” from 10 kHz min. to 2 MHz max. (0.1; 0.2; 0.4; 1; 2; 4; 10 and 20 kHz selectable step) Supplied accessories • Ac power supply and batteries recharger • Instruction manual Optional accessories LT01 - Softpack carrying case LT05 - Fixed Balanced Attenuator: 3 or 6 or 10 or 20 or 30 or 40 dB 150 Ω (120 or 135 Ω on request) and 600 Ω LT02 - Headset LT03 - BNC to Triple Banana Jack Adapter LT06 - Balance Measure Adapter: 150Ω (120 or 135 Ω on request) and 600 Ω LT04 - Banana / Crocodile cable LT07 – Resistive Termination: 150 Ω (120 or 135 Ω on request) or 600 Ω. The informations contained in this document are subject to change without notice LT2000 - Field application Near Cross-talk Noise or Level measurement measurement TX TRX RX ? line under test Zo interfering line Zo line under test TRX RX Zo = nominal termination 150 (120 or 135) or 600 Ohm Return Loss Attenuation measurement measurement TX Zo TRX TRX TX RX line under test line under test RX Zo = nominal termnation 150 (120 or 135) or 600 Ohm Longitudinal Balance measurement Balance Measure Adapter TRX TX Zo line under test RX Zo = nominal termnation 150 (120 or 135) or 600 Ohm Via dei Lavoratori, 6 – 04010 LATINA ITALY Tel +39 0773 240.696 - Fax +39 0773 240.676 E-Mail sales@aten.it - WEB http://www.aten.it TRX TRX