Peppers Cable Glands Limited Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom Telephone: +44 (0) 1276 64232 Facsimile: +44 (0) 1276 691752 Email: sales@peppers.co.uk CROCLOCK®: Type UL-C Part of our UL Range 2006 Catalogue Page 4.4.0 UL-C Type Explosion-proof glands featuring Croclock®, provide a compound seal preventing the passage of gas or vapours through the gland and the propagation of flame into the cable core. The glands are UL listed; suitable for Marine Shipboard Jacketed or non-Jacketed cable; NEMA 4X applications and are Deluge-Proof. Design Standard UL2225 & UL514B CERTIFication CLASS I, DIVISION 1 B GAS GROUPS ABCD File No. E248936 CERTIFicate A C D GLAND MARKING Example: UL-CBR 20 1/2 NPT PEPPERS GU15 3BT UK CL I DIV 1 ABCD ABCD CL I Zone 1 IIC -25+85ºC 4X APPLICATION Class I, Division 1 Croclock® UL-C type glands will maintain the Explosion-Proof integrity of electrical equipment when used with suitable listed cable types. NEC 505: Class I, Zone 1, Gas Groups IIC, IIB, IIA. Croclock® UL-C type glands will maintain the Flameproof integrity of electrical equipment when used with suitable listed cable types. INGRESS PROTECTION NEMA 4X. Meets the requirements of DTS01 1991 and IP66 Enviromental and Ingress Protection may be reduced when using unjacketed cable CURING TIME @21ºC Conductor termination can be effected after 1 hour The equipment can be energised after 4 hours MATERIALS Brass CZ121 (UL-CB) Stainless Steel 316 (UL-CS) Inner LSOH compound Standard outer sheath seal is LSOH silicone, white Reduced bore outer sheath seal is LSOH silicone, red (UL-C*R) options THREADS ISO Metric; NPT; NPSM plating Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard OPERATING TEMPERATURES -25ºC to +85ºC 2006 Catalogue Page 4.4.0 © Peppers Cable Glands Limited 2006 accessories Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN) Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET) IP Washer - Nylon (ACNSW); Red Fibre (ACFSW) Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW) Shroud - PVC (ACSPVC) example part number Sample: UL-CBR / 20 / 050NPT UL-C - Gland type, armour type (SWA) and body material (Brass) UL-*B - Material (Brass) UL-**R - Reduced bore outer seal 20 - Fitting size = 20 050NPT - 1/2”NPT entry thread Gland Size Entry Threads Entry Thread Length [B] Metric NPT Max Max Across Protrusion Corners Length Gland Seal Range [A] Max Inner Sheath NPT Armour Acceptance Range Cable Outer Sheath [D] Cable Inner Sheath [C] Standard Shroud Size Reduced (R) Min Max Min Max 16 M20 1⁄2” or 3⁄4” 0.783 1.102 2.835 0.461 0.362 0.531 0.264 0.406 0.006-0.049 L24 20s M20 1⁄2” or 3⁄4” 0.783 1.102 2.835 0.461 0.453 0.630 0.370 0.492 0.006-0.049 L24 1⁄2” 3⁄4” 20 M20 25 M25 or 3⁄4” 1” or or 1” 11⁄4” 0.783 1.299 2.874 0.551 0.610 0.831 0.563 0.693 0.006-0.049 EL30 0.795 1.630 3.268 0.787 0.799 1.079 0.689 0.941 0.006-0.063 EL38 32 M32 40 M40 50s M50 2” 1.059 2.815 4.528 1.504 50 M50 2” 1.059 2.815 4.528 1.736 1.571 4.528 1.972 1.571 4.528 2.205 11⁄4” or 11⁄2” 0.985 1.992 4.055 1.035 1.051 1.339 0.984 1.201 0.006-0.079 EL46 1.008 2.382 4.134 1.268 1.299 1.598 1.154 1.425 0.008-0.079 EL55 1.551 1.839 1.499 1.669 0.008-0.098 EL65 1.799 2.094 1.618 1.909 0.008-0.098 EL65 2.051 2.343 1.846 2.157 0.012-0.098 EL80 2.299 2.591 2.118 2.409 0.012-0.098 EL80 63s M63 21⁄2” 63 M63 21⁄2” 75s M75 3” 1.634 4.803 2.441 2.551 2.843 2.469 2.677 0.012-0.098 EL104 75 M75 3” 1.634 4.803 2.677 2.799 3.071 2.618 2.890 0.012-0.098 EL104 All Dimensions are in inches All Dimensions are in Millimetres NOTES: ● Gland Size does not necessarily equate to the entry thread size ● Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required ● Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for specific dimensions ● Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch ● Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full ● For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886 clause 6.1 as follows:- NPT threads must have at least five threads fully engaged Metric and NPS threads must have at least eight threads fully engaged http://www.cableglands.com © Peppers Cable Glands Limited 2006 Page 4.4.0 2006 Catalogue Peppers Cable Glands Limited Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom Telephone: +44 (0) 1276 64232 Facsimile: +44 (0) 1276 691752 Email: sales@peppers.co.uk Type UL-X Part of our UL Range 2006 Catalogue Page 4.5.0 UL-X Type Explosion-proof glands provide a compound seal preventing the passage of gas or vapours through the gland and the propagation of flame into the cable core. The glands are UL listed; suitable for Marine Shipboard non-armoured cable; NEMA 4X applications and are Deluge-Proof. Design Standard UL2225 & UL514B CLASS I, DIVISION 2 CERTIFication GAS GROUPS ABCD CERTIFicate File No. E248936 GLAND MARKING Example: UL-XB 20 1/2 NPT PEPPERS GU15 3BT UK CL I DIV 2 ABCD CL I Zone 2 IIC -25+85ºC 4X APPLICATION Class I, Division 2 ABCD UL-X type glands will maintain the Explosion-Proof integrity of electrical equipment when used with suitable listed cable types. NEC 505: Class I, Zone 2, Gas Groups IIC, IIB, IIA. UL-X type glands will maintain the Flameproof integrity of electrical equipment when used with suitable listed cable types. INGRESS PROTECTION NEMA 4X. Meets the requirements of DTS01 1991 CURING TIME @21ºC Conductor termination can be effected after 1 hour The equipment can be energised after 4 hours MATERIALS Brass CZ121 (UL-XB) Stainless Steel 316 (UL-XS) Inner LSOH compound options THREADS ISO Metric; NPT; NPSM plating Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard OPERATING TEMPERATURES -25ºC to +85ºC 2006 Catalogue Page 4.5.0 © Peppers Cable Glands Limited 2006 accessories Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN) Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET) IP Washer - Nylon (ACNSW); Red Fibre (ACFSW) Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW) Shroud - PVC (ACSPVC) example part number Sample: UL-XB / 20 / 050NPT UL-X - Gland type UL-*B - Material (Brass) 20 - Fitting size = 20 050NPT - 1/2”NPT entry thread Gland Size Trade Size Entry Thread Length [B] Metric NPT Max Max Across Protrusion Corners Length Maximum Sheath Diameter [C] Shroud Size [A] NPT 20s M20 1⁄2” or 3⁄4” 0.783 1.102 1.654 0.461 L24 20 M20 1⁄2” or 3⁄4” 0.783 1.299 1.732 0.551 L30 25 M25 3⁄4” or 1” 0.795 1.630 1.890 0.787 L38 32 M32 1” or 11⁄4” 0.985 1.992 2.087 1.035 L46 11⁄4” or 11⁄2” 40 M40 50 M50 2” 1.008 2.382 2.126 1.268 L55 1.059 2.815 2.126 1.736 L65 63 M63 21⁄2” 1.571 75 M75 3” 1.634 3.465 2.165 2.205 L80 4.134 2.362 2.677 L90 All Dimensions are in inches NOTES: ● Gland Size does not necessarily equate to the entry thread size ● Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required ● Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for specific dimensions ● Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch ● Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full ● For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886 clause 6.4.1 as follows:- NPT threads must have at least five threads fully engaged Metric and NPS threads must have at least eight threads fully engaged http://www.cableglands.com © Peppers Cable Glands Limited 2006 Page 4.5.0 2006 Catalogue Peppers Cable Glands Limited Stanhope Road, Camberley, Surrey, GU15 3BT United Kingdom Telephone: +44 (0) 1276 64232 Facsimile: +44 (0) 1276 691752 Email: sales@peppers.co.uk Type UL-U Part of our UL Range 2006 Catalogue Page 4.5.1 UL-U Type Explosion-proof glands featuring provide a compound seal preventing the passage of gas or vapours through the gland and the propagation of flame into the cable core. The glands are UL listed; suitable for Marine Shipboard non-armoured cable; NEMA 4X applications and are Deluge-Proof. Design Standard UL2225 & UL514B CERTIFication CLASS I, DIVISION 2 GAS GROUPS ABCD CERTIFicate File No. E248936 GLAND MARKING Example: UL-UB 20 1/2 NPT PEPPERS GU15 3BT UK CL I DIV 2 ABCD CL I Zone 2 IIC -25+85ºC 4X APPLICATION Class I, Division 2 ABCD UL-U type glands will maintain the Explosion-Proof integrity of electrical equipment when used with suitable listed cable types. NEC 505: Class I, Zone 2, Gas Groups IIC, IIB, IIA. UL-U type glands will maintain the Flameproof integrity of electrical equipment when used with suitable listed cable types. INGRESS PROTECTION NEMA 4X. Meets the requirements of DTS01 1991 CURING TIME @21ºC Conductor termination can be effected after 1 hour The equipment can be energised after 4 hours MATERIALS Brass CZ121 (UL-UB) Stainless Steel 316 (UL-US) Inner LSOH compound Standard outer sheath seal is LSOH silicone, white options THREADS ISO Metric; NPT; NPSM plating Zinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN) - All entry threads are nickel plated as standard OPERATING TEMPERATURES -25ºC to +85ºC 2006 Catalogue Page 4.5.1 © Peppers Cable Glands Limited 2006 accessories Locknut - Brass (ACBLN); 316 Stainless Steel (ACSLN) Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET) IP Washer - Nylon (ACNSW); Red Fibre (ACFSW) Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW) Shroud - PVC (ACSPVC) example part number Sample: UL-UB / 20 / 050NPT UL-U - Gland type UL-*B - Material (Brass) 20 - Fitting size = 20 050NPT - 1/2”NPT entry thread Gland Size Entry Threads Entry Thread Length [B] Metric NPT Max Max Across Protrusion Corners Length Gland Seal Range Cable Inner Sheath [C] [A] Max Inner Sheath NPT Cable Outer Sheath [D] Min Shroud Size Max 16 M20 1⁄2” or 3⁄4” 0.783 1.102 2.835 0.461 0.134 0.331 L24 20s M20 1⁄2” or 3⁄4” 0.783 1.102 2.835 0.461 0.189 0.461 L24 1⁄2” 3⁄4” 20 M20 25 M25 3⁄4” or 32 M32 1” or 11⁄4” 0.985 1.992 4.055 1.035 0.713 1.035 EL46 40 M40 11⁄4” or 11⁄2” 1.008 2.382 4.134 1.268 0.890 1.268 EL55 50s M50 2” 1.059 2.815 4.528 1.504 1.110 1.504 EL65 50 M50 2” 1.059 2.815 4.528 1.736 1.303 1.736 EL65 63s M63 21⁄2” 1.571 3.465 4.528 1.972 1.547 1.972 EL80 63 M63 21⁄2” 1.571 3.465 4.528 2.205 1.839 2.205 EL80 75s M75 3” 1.634 4.134 4.803 2.441 2.059 2.441 EL104 75 M75 3” 1.634 4.134 4.803 2.677 2.283 2.677 EL104 or 1” 0.783 1.299 2.874 0.551 0.374 0.551 EL30 0.795 1.630 3.268 0.787 0.461 0.787 EL38 All Dimensions are in inches NOTES: ● Gland Size does not necessarily equate to the entry thread size ● Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required ● Please note that dimensions (A) and (B) may differ for glands with parallel entry threads. Please refer to our thread data tables for specific dimensions ● Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch ● Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full ● For Class I Group A locations, the joint made by fitting the gland to the enclosure female thread must comply with standard UL 886 clause 6.4.1 as follows:- NPT threads must have at least five threads fully engaged Metric and NPS threads must have at least eight threads fully engaged http://www.cableglands.com © Peppers Cable Glands Limited 2006 Page 4.5.1 2006 Catalogue