Sartorius Combics Ex Intelligent weighing in hazardous locations Sartorius Combics 3 Ex: the series with many combination options The explosion-proof indicators of the Combics 3 series from Sartorius are ideally suited for use in hazardous locations where explosive gas and dust mixtures occur . The many possibilities for combining Combics 3 explosion-proof equipment is characteristic of today's flexibility. You can have a complete weighing solution in stainless steel with Combics explosion-protected platforms (standard capacities up to 15,000 lbs). If you need a precision platform with high accuracy along with your high-capacity platform, you can connect an additional digital IS platform to the Combics 3 display and control unit. An even broader field of weighing applications is opened with the connection of Sartorius Hamburg load cell solutions. The Ex approval rating on Combics indicators is extended to all components. This lets you take advantage of the full performance potential of the Combics' built-in A|D converter. Documents verifying intrinsic safety are included with your explosion-protected Combics 3 indicator, to make your system configuration simpler and more economical. The Combics data interfaces with upgradeable modules ensure future-proof capabilities for documentation, data transmission and networking. The flexibility of the Combics 3 indicator includes the power supply options as well. Simply choose the basic indicator model you need, and use the power supply that best suits conditions in your premises at any given time. You can use a 110 to 230 V power supply located inside or outside the hazardous EX battery pack is also available for mobile operation. Thanks to the application programs integrated into the explosion-proof Combics 3 indicator, you can upgrade or configure your indicator's functionality at any time, depending on the tasks at hand. Use Combics 3 as a simple weight indicator for platforms and weigh cells, with all the benefits of convenient operation and configuration and the excellent readability of its backlit graphical display, or as a sophisticated terminal with application programs, such as checkweighing, classification or filling. And Combics 3 is bus-capable, for trouble-free integration into a higher-order process control system. Combics 3 Ex from Sartorius: the "brains" behind all your weighing operations. It works hard for you, where you need it most. CL I|DIV 1,2 CL II, III DIV 1,2 Configuration examples Combics Ex components Configurations with platforms Non-hazardous location Hazardous location Combics EX platform, CAPXS… IFXS4 flat-bed scale Can be networked with up to 8 Workstations Combics EX indicator PLC or PC Interface converter or Zener barrier IUXS4 pallet scale IS-X precision platform Alternative configuration versions FM approval (American and Canadian standard) intriusically safe permitted class I = gas II = dust III = fibres area classification (permitted Division = US NEC 500) permitted group (gas|dust) IS CL I, II, III, DIV 1, 2, GP A, B, C, D, E, F, G T4 T code T4 = 135°C maximumsurface temperature Group A: Acetylene Group B: Hydrogon Group C: Ethylone Group D: Propaue Group E: Metal dust Group F: Cool dust Group G: Grain dust CL I, Zone 1, AEx ib IIC T4 CL II, Zone 20 (NEC 500) permitted class permitted Zone Amercan National Standard Explosionprotected protection kind (intrinsically safe) Group gas group temperature class Power supply module specifications Input voltage 100 ... 240 VAC Consumption: 25 VA; frequency: 50|60 Hz for: YPS02-XKR (Power supply for installation in hazardous location) FM: XP for CL I,II,III DIV1 GP A,B,C,D,E,F,G T4 I.S. connections to CL I,I,II DIV 1 GP A,B,C,D,E,F,G CSA: [Ex ia] CL I,II,III DIV1 GP A,B,C,D,E,F,G T4 YPS02-ZKR (Power supply for installation in non-hazardous location), FM: AIS CL I,II,III DIV1 GP A,B,C,D,E,F,G CSA: [Ex ia] associated equipment CL I,II,III DIV1 GP A,B,C,D,E,F,G YRB02-X (External rechargeable battery pack for use in hazardous location, with deep discharge protection) Approx. 30 hours operation, depending on conditions of installation and use FM: Intrinsically safe connections for AIS CL I,II,III DIV 1 GP A,B,C,D,E,F,G T4 or installation in CL I, Zone 1 IIC or installation in CL II, Zone 20 for indoor use only Data interface converter YDI05-ZU1 / YDI05-ZU2 / YDI05-ZU3 FM (US and canadian standard): AIS CL I,I,II DIV 1,2 GP A,B,C,D,E,F,G CL I,II Zone1,20 [AEx ib] IIB/IIC Indicator Specifications Explosion protection FM (NEC 500): I.S. CL I, II, II DIV 1, 2 GP A, B, C, D, E, F, G T4 FM: (NEC 505): CL I, II Zone 1, 20 AEx ib IIC T4 Marking for FM/canadian standard similar 5,5 V (± 2,75 V) 6- or 4-conductor technology Display 108 + 58 mm graphic display, backlit 248 + 128 pixels 83 ohms to 2,000 ohms Performance specifications of the integrated A/D converter, weighing capacity Up to 32 t Maximum readability < 62,500 digits Load cell connection Supply voltage Available sensor technology Bridge impedance Measuring signal 0.3 mV to 36 mV Housing Material AISI 304 stainless steel Dust and water protection acc. to EN60529 IP67 Measuring signal dead load 0.3 mV to 6.3 mV Operating temperature range -10°C to +40°C (+14 to +104°F) Measuring signal variation 43 mV to 19.8 mV Power supply Sensitivity 4 million digits max. (internal) Data interface Bidirectional RS-232C interface with control outputs (standard equipment) Bi-directional COM2 inerface as RS-232C, RS-422 or RS-485 (standard equipment) DC supply Battery operation 100-240 VAC (-15|+10%), 50-60Hz, max. 17W|25 VA Optional 15.5 - 24 VDC (±10%), max. 10 W Optional external rechargeable battery pack Limitation of emissions Acc. to EN61326+A1, Class B (IEC 61326+A1) Optional Defined immunity to interference Acc. to EN61326+A1, industrial environment (IEC 61326+A1) Electrical safety Acc. to EN61010-1 (EC 1010-1), EN60950 (IEC 950) Additional data interface Typical minimum configuration of a Combics scale: Hazardous Location Non-hazardous location (safe location) Interface converter or Zener barrier Power supply (110 V-230 V) * for possible installation locations see certificate Battery pack* Power supply (110 V-230 V) Sartorius Combics 3 Ex: indicator and accessories Combics 3 indicator, stainless steel housing, IP67 protected CIXS3-U (incl. 1 RS-232C interface and 1 configurable interface for RS-232C, RS-422 or RS-485 data communication) Printers and printer accessories Verifiable printer with functions for date, time and statistical evaluations YDP03-0CE Printer paper (5 rolls; length per roll: 50 m) for data printer 6906937 Replacement ink ribbon cartridge for printer 6906918 Verifiable strip and label printer with thermal direct print head, paper width 108 mm, with adapter cable (12-contact round connector) and external power supply Adapter cable YCC01-01CISLM3 required for CISL models. With 120-V power supply (USA) YDP12IS-0CE-V120 With 220-V power supply (EU) YDP12IS-0CE-V220 With 240-V power supply (UK) YDP12IS-0CE-V240 Printer paper (1 roll) for YDP12IS –0CE printer, 108 mm + 75 m, thermal-sensitive paper 69Y03196 Labels for YDP12IS-OCE printer, extra large, 108 + 127 m, 305 labels 69Y03195 Verifiable strip and label printer with thermal print head, paper width 60 mm, with adapter cable (12-contact round connector) and external power supply. Adapter cable YCC01-01CISLM3 required for CISL models. With 120-V power supply (USA) YDP04IS-0CE-V120 With 220-V power supply (EU) YDP04IS-0CE-V220 With 240-V power supply (UK) YDP04IS-0CE-V240 Printer paper (3 rolls) for YDP02/04IS-0CE, 60 mm + 75 m, thermal sensitive paper 69Y03090 Labels for YDP02/04IS-0CE, small, 58 x 30 mm, 1,000 labels 69Y03092 Labels for YDP02/04IS-0CE, medium, 58 x 76 mm, 500 labels 69Y03093 Labels for YDP02/04IS-0CE, large, 58 x 100 mm, 350 labels 69Y03094 Mechanical accessories Installation kit for pit frame installation (disconnectable, plug-in style cable for Combics indicator) YAS99I Brackets for wall mounting, stainless steel YDH02CIS Floor-mounted column YDH03CIP Floor-mounted column, stainless steel YDH03CIS Base for installing floor-mounted column YBP03CIP Base for installing floor-mounted column, stainless steel YBP03CIS Retainer for mounting external battery pack YBPH01 Software Flexible formatting options for printouts (e.g., for bar codes with variable font size, graphics, etc.) – Ask your sales consultant Power supplies Battery charger for YRB02-X external rechargeable battery pack YRB02LD External rechargeable battery pack, min. 30 hours’ operation YRB02-X Flame-proof power supply for use in hazardous locations, 100 to 240 V YPS02-XKR Power supply for use in safe locations, 100 to 240 V YPS02-ZKR Connecting cables Cable with cable gland for connecting a scale or an IS platform, compact scale 14-pin round male connector, 0.2 m YCC02-XR14 M6 Cable with cable gland for connecting a Zener barrier, 6 m YCC02-XR14 F02 Additional accessories In-use dust covers (2) Anti-theft locking device Cable gland for Combics CIS models; IP67 protected Zener barrier for network connection (without cable)* Zener barrier for connecting a printer and|or PC , 20-m cable in safe location (cable YCC02-XR14F02 required) Zener barrier, as for YDI02-Z, with open cable ends for connection via a cable gland, 20 m Zener barrier (4 data lines, 4 control lines), 20 m cable in safe location (cable YCC02-XR14F02 required) Zener barriers type Z966 without cable and housing (for inputs of relay box VF3086 or for installation in a switch-caninet) Foot switch for activation the tare/print function; cable length: 2 m (Installation via our Fast Factory) Converter RS-232C-RS-232C incl. 20 m cable with open cable ends (for CIXS3-U) Converter RS-232C-RS-232C incl. 20 m cable with 14 pin plug (for FC-X, IS-X) Converter RS-422C-RS-232C cable YCC422-X needed with 14 pin plug (custimized length) 1 piece = 1 m Data output RS-232C instead of weighing point 1 for connecting FC-X, FCA-X or IS-X (with optional RS232C data output) Internal batching/filling PCB for COM1 for controlling a coarse and a fine feed valve (electrically connected/eletrically isolated for H3 YDC01CI-X YTP01CI YAS04CIS YDI01-Z YDI02-Z YDI02-ZCX YDI03-Z 69Y01046 YPE05-X YDI05-ZU1 YDI05-ZU2 YDI05-ZU3 YDO02C-X YDO03C-X * YCC485-X connecting cable required (1 piece = 1 m) "Basic Filling" and "Filling with Extras" application kits for single-component filling can be installed in the indicator. Application kit "Basic Filling" "Filling with Extras" Please contact us for information on the required accessories. H3 H4 ** for single-component filling Accessory Filling application kits H3 + H4 External filling device (see YDO03C-X), incl. 2 m cable (for H3) YSB01CI-X Relay box for installation in a non-hazardous location to data port VF3086 COM2: 8 outputs (coarse and fine feed valve + 6 configurable outputs) and 7 inputs (incl. 1 Zener barrier for 2 inputs – retrofittable with further Zener barriers for up to 7 inputs) (for H4) You can order a complete installed configuration CIXS3-U with Combics-Ex-Platforms (CAPXS-U-, IFXS4, IUXS4) Sartorius North America 131 Heartland Boulevard, Edgewood, New York 11717, USA Phone 800-635-2906 Fax 631-374-8837 www.sartorius.com Specifications subject to change without notice. Printed in Germany on paper that has been bleached without any use of chlorine. W/sart-000 · G Publication No.: WCO1006-am06031 Order No.: 98649-006-36