RF-LAMBDA RFLUPA0506GE LEADER OF RF BROADBAND SOLUTIONS 10W Ultra Wide Band Power Amplifier 0.5GHz~6GHz Feature Gain: 35dB typical Output power +38dBm typical High P1dB: +35dB m Full Band Supply Voltage: +28V @ 350 m A 50 Ohm Matched Input / Output Size: 3.56” x 2.93” x0.47” Typical Applications • • • • • Wireless Infrastructure RF Microwave & VSAT Military & Aerospace Test Instrument Fiber Optics Electrical Specifications, TA = +25° C, With Vcc = +28V, 50 Ohm System Parameter Min. Frequency Range 0.5 Gain 29 Gain Flatness Gain Variation Over Temperature5 (‐45 ~ +85) Input VSWR Output Power for 1 dB Compression (P1dB) 35 Typ. 2 32 Max. Units 6 GHz dB ±5 ±3 dB ±1.5 ±1.5 dB 2.5 2.5 38 Supply Current (Idd) (Vcc=+28V) 350 Input Max Power(no damage) 2 Typ. 34 40 60 Min. 35 Saturated Output Power (Psat) Isolation S12 Max. 35 1500 37 dBm 39 dBm 350 65 55 1500 mA 60 dB +8 Weight +8 dBm 5.99 ounces Impedance 50 Ohms Input /Output Connector SMA‐Female Finishing Material Package Sealing Ultra Wide Band Power Amplifier 0.5GHz~6GHz • • • • • • Standard: Gold 40 micron; Nickel 220 micron thickness Option: Gold 80 micron; Nickel 180 micron thickness Aluminum Epoxy Sealing (Standard) Hermetically Seal (Option with extra charge) RF-LAMBDA USA. Sales: sales@rflambda.com www.rflambda.com Technical : support@rflambda.com RF-LAMBDA RFLUPA0506GE LEADER OF RF BROADBAND SOLUTIONS Application Note Step for Use Step 2. After connect +28V DC biasing, the current drawing should be about 50~100mA, all LED indication lights should be green. Step 3. Push HV‐ON button and then release. The LED PWR should change from “Green” to “Red”, and +28V Power Supply should draw 0.5~0.8A. At this point, PA is fully ready for operation. Step 4. Turn on RF Input power. Amplifier Use Ensure that the amplifier input and output ports are safely terminated into a proper 50 ohm load before turning on the power. Never operate the amplifier without a load. A proper 50 ohm load is defined as a load with impedance less than 1.9:1 or return loss larger than 10dB relative to 50 Ohm within the specified operating band width. Power Supply Requirements Power supply must be able to provide adequate current for the amplifier. Power supply should be able to provide 1.5 times the typical current or 1.2 times the maximum current (whichever is greater). In most cases, RF‐Lambda amplifiers will withstand severe mismatches without damage. However, operation with poor loads is discouraged. If prolonged operation with poor or unknown loads is expected, an external device such as an isolator or circulator should be used to protect the amplifier. Ensure that the power is off when connecting or disconnecting the input or output of the amp. Ultra Wide Band Power Amplifier 0.5GHz~6GHz Step 1. RF Input and output ports can NOT be “OPEN” , must be fully connected or terminated with 50 ohm impedance. The input RF signal must be turned off. Prevent overdriving the amplifier. Do not exceed the recommended input power level. Adequate heat‐sinking required for RF amplifier modules. Please inquire. Amplifiers do not contain Thermal protection, Reverse DC polarity or Over voltage protection with the exception of a few models. Please inquire. Proper electrostatic discharge (ESD) precautions are recommended to avoid performance degradation or loss of functionality. What is not covered with warranty? Each of RF‐Lambda amplifiers will go through power and temperature stress testing. Due to fragile of the die, IC or MMIC, those are not covered by warranty. Any damage to those will NOT be free to repair. RF-LAMBDA USA. Sales: sales@rflambda.com www.rflambda.com Technical : support@rflambda.com RF-LAMBDA RFLUPA0506GE LEADER OF RF BROADBAND SOLUTIONS Absolute Maximum Ratings +28V +8dB m ‐45 to +85 ‐55 to +125 Operational Temperature (C°) ‐45 to +85(Case Temperature) Storage Temperature (C°) ‐55 to +125 30,000 ft. (Epoxy Seal Controlled environment) Biasing Up Procedure Step 1 Connect Ground Pin Step 2 Connect input and output Step 3 Connect +28V biasing 60,000 ft 1.0psi min (Hermetically Seal Un‐ controlled environment) (Optional) Altitude Vibration 25g rms (15 degree 2KHz) endurance, 1 hour per axis Humidity 100% RH at 35c, 95%RH at 40ºc Shock 20G for 11msc half sin wave,3 axis both directions Power OFF Procedure Step 1 Turn off +28V biasing Step 2 Remove RF connection Step 3 Remove Ground. Typical Performance Plots Gain Input VSWR Trc1 S11 SWR 1 U / Ref 1 U Trc3 S21 dB Mag 10 dB / Ref 80 dB Cal Math 3 Mem5[Trc3] S21 dB Mag 10 dB / Ref 80 dB Invisible 80 M1 500.00000 MHz 34.870 dB S21 70 • M2 2.000000 GHz 36.648 dB 60 M3 6.000000 GHz 37.336 dB 50 M3 M2 M1 40 30 20 10 0 -10 Ch1 Base Freq Start Base 300Pwr MHz-25 dBm 9 7 6 5 4 M1 3 M2 M3 2 1 Ch1 Base Freq Start Base 300Pwr MHz-25 dBm Stop 6.2 GHz Cain vs. output power Gain vs. Output Power Trc2 S12 dB Mag 10 dB / Ref 0 dB Cal 2 0 M1 500.00000 MHz -65.237 dB S12 -10 M2 2.000000 GHz -57.777 dB M3 6.000000 GHz -56.837 dB -20 44 43 42 41 -30 M2 M3 Gain(dB) 40 -40 -50 M1 -60 1 8 Stop 6.2 GHz Isolation Cal M1 500.00000 MHz 1.4706 U M2 2.000000 GHz 1.7912 U M3 6.000000 GHz 1.5005 U S11 10 Ultra Wide Band Power Amplifier 0.5GHz~6GHz Operating Voltage RF Input Power Operating Case Temperature(C°) Storage Temperature(C°) Environment specifications 39 -70 37 -80 36 -90 35 Ch1 Base Freq Start Base 300Pwr MHz-25 dBm 0.5GHz 1GHz 1.5GHz 2GHz 2.5GHz 3GHz 3.5GHz 4GHz 4.5GHz 5GHz 5.5GHz 6GHz 38 Stop 6.2 GHz 34 20 25 30 35 40 45 Output Power(dBm) RF-LAMBDA USA. Sales: sales@rflambda.com www.rflambda.com Technical : support@rflambda.com RF-LAMBDA RFLUPA0506GE LEADER OF RF BROADBAND SOLUTIONS P1dB vs. Frequency Current P1dB vs. Frequency 50 Current vs. Output Power 1400 45 1200 40 1000 Current(mA) P1dB(dBm) 30 25 20 800 600 400 15 200 10 5 0 1 2 3 4 5 0 26 6 Frequency(GHz) 28 30 32 34 36 38 40 Output Power(dBm) 3th Harmonic Wave output Power 2nd Harmonic Wave output Power 2nd Harmonic Wave vs. Output Power 3rd Harmonic Wave vs. Output Power 0 5 0 -10 -10 + -15 -20 -25 -30 0.5GHz 1GHz 1.5GHz 2GHz 2.5GHz 3GHz 3.5GHz 4GHz 4.5GHz 5GHz 5.5GHz 6GHz -35 -40 -45 20 25 30 35 40 45 Output Power(dBm) 3rd Harmonic Wave(dBc) 2nd Harmonic Wave(dBc) -5 -20 + -30 -40 -50 0.5GHz 1GHz 1.5GHz 2GHz 2.5GHz 3GHz 3.5GHz 4GHz 4.5GHz 5GHz 5.5GHz 6GHz -60 -70 20 25 30 35 40 Output Power(dBm) 45 Ultra Wide Band Power Amplifier 0.5GHz~6GHz 35 4th Harmonic Wave output Power 4th Harmonic Wave vs. Output Power 0 -10 4th Harmonic Wave(dBc) -20 -30 -40 0.5GHz 1GHz 1.5GHz 2GHz 2.5GHz 3GHz 3.5GHz 4GHz 4.5GHz 5GHz 5.5GHz 6GHz -50 -60 -70 -80 -90 20 25 30 35 40 45 Output Power(dBm) RF-LAMBDA USA. Sales: sales@rflambda.com www.rflambda.com Technical : support@rflambda.com RF-LAMBDA RFLUPA0506GE LEADER OF RF BROADBAND SOLUTIONS Outline Drawing: All Dimensions in mm(inches) Heat Sink required during operation 12 [0.47] 6 [0.24] Ultra Wide Band Power Amplifier 0.5GHz~6GHz 4- 2.8[0.11] THRU 70.1 [2.76] 10.5 [0.41] RFLUPA0506GE GND F:0.5-6GHz +28V SN:XXXXXXXXXX OUT 31.2 [1.23] RF-Lambda 12 [0.47] 74.5 [2.93] IN 86 [3.39] 90.4 [3.56] Ordering Information Part No ECCN RFLUPA0506GE EAR99 Description 0.5‐6GHz Power Amplifier Important Notice The information contained herein is believed to be reliable. RF‐Lambda makes no warranties regarding the information contained herein. RF‐Lambda assumes no responsibility or liability whatsoever for any of the information contained herein. RF‐Lambda assumes no responsibility or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for RF‐Lambda products. The information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by such information. RF‐Lambda products are not warranted or authorized for use as critical components in medical, life‐saving, or life sustaining applications, or other applications where a failure would reasonably be expected to cause severe personal injury or death. RF-LAMBDA USA. Sales: sales@rflambda.com www.rflambda.com Technical : support@rflambda.com