Report No. 100014113DAL-001 JPL Industries, Inc. Page 5 of 15

advertisement
Report No. 100014113DAL-001
JPL Industries, Inc.
Issued: 27-Sep-2010
Revised: 15-Apr-2013
Page 5 of 15
4.0 Critical Components
Photo #
Item
Name
no.1
Manufacturer/
trademark2
Type / model
1, 2
1
PWB
Various
Various
1
2
MOVs (For 4803P model)
Various
MDE
SS550MOV
2
3
MOVs (For 240C
and 240-3P
models)
Various
MDE
SS320MOV
1, 2
4
Terminal Blocks
Various
Various
2
Technical data and securement
means
Flame rating: 94V-0, Opertaing
Temp: 130 deg C
Thermally Protected MOV, Type 4,
MCOV 550VAC, In 20kA, SCCR
100kA, VPR 1500V
Thermally Protected MOV, Type 4,
MCOV 320VAC, In 20kA, SCCR
100kA, VPR 1200V
Flame rating: 94V-0, Operating
Temp: 90 deg C, 4 way mount
5mm hole diameter, Current
Rating up to 12A @ 300V
Mark(s) of
conformity
3
cURus
cETLus
cETLus
cURus
NOTES:
1) Not all item numbers are indicated (called out) in the photos, as their location is obvious.
2) “Various“ means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s)
of conformity" can be used.
3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR" - indicates Unlisted and only
visual examination is necessary. "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for
details.
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 100014113DAL-001
JPL Industries, Inc.
8.0 Test Summary
Evaluation Period
02/23/10-03/26/10
Sample Rec. Date
18/02/10
Page 9 of 15
Condition Production
Issued: 27-Sep-2010
Revised: 15-Apr-2013
Project No. G100014113
DAL1002161343[
Sample ID.
001-005]
1809 10th Street, Suite #400, Plano, TX 75074
Test Location
Testing Lab
Test Procedure
Determination of the result includes consideration of measurement uncertainty from the test equipment and
methods. The product was tested as indicated below with results in conformance to the relevant test criteria.
The following tests were performed:
ANSI/UL 1449
Test Description
Dielectric Voltage-Withstand Test
35
Surge Testing
37
Operational Voltage Test
37
Limited current abnormal overvoltage test
39.4
4/22/2013
Evaluation Period
Project No. G100014113
"Due to the previous testing performed and reported above no additional testing was necessary for "UL Standard
for Safety for Surge Protective Devices - 3rd Edition; Issued: 29-Sep-2006, Revisions through and including 18Oct-2010 (ANSI/UL 1449)"
8.1 Signatures
A representative sample of the product covered by this report has been evaluated and found to comply with the
M.J. Smith
Javier Lozano
Completed by:
Reviewed by:
Compliance Investigator
Senior Compliance Investigator
Title:
Title:
Signature:
Signature:
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 100014113DAL-001
JPL Industries, Inc.
Page 10 of 15
Issued: 27-Sep-2010
Revised: 15-Apr-2013
9.0 Correlation Page For Multiple Listings
The following products, which are identical to those identified in this report except for model number and Listee
name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.
JPL Industries, Inc.
BASIC LISTEE
PO Box 6611
Address
Lubbock, TX 79493
USA
Country
Type 4 Surge Protection Devices
Product
MULTIPLE LISTEE 1 None
Address
Country
Brand Name
ASSOCIATED
MANUFACTURER
Address
Country
MULTIPLE LISTEE 1 MODELS
BASIC LISTEE MODELS
MULTIPLE LISTEE 2 None
Address
Country
Brand Name
ASSOCIATED
MANUFACTURER
Address
Country
MULTIPLE LISTEE 2 MODELS
BASIC LISTEE MODELS
MULTIPLE LISTEE 3 None
Address
Country
Brand Name
ASSOCIATED
MANUFACTURER
Address
Country
MULTIPLE LISTEE 3 MODELS
BASIC LISTEE MODELS
ED 16.3.15 (1-Jan-13) Mandatory
Report No. 100014113DAL-001
JPL Industries, Inc.
Page 14 of 15
Issued: 27-Sep-2010
Revised: 15-Apr-2013
12.0 Revision Summary
The following changes are in compliance with the declaration of Section 8.1:
Date/
Project Handler/
Section Item Description of Change
Proj # Site ID Reviewer
Michael Smith
1
--
Javier Lozano
1
--
4
7
4
--
15-Apr-2013
G101137262DAL
Changed manufacturer from JPL Industries to Gesper
Marketing, Inc.
Updated Standard from revision date May 3, 2010 to revision
date 10/18/2010. The change in the standard is
administrational.
Changed opertaing to operating
Added new test section with signatures
ED 16.3.15 (1-Jan-13) Mandatory
Download