Datasheet Amplicon.com IT and Instrumentation for industry Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com Datasheet Online UPS : Zero Transfer Time Absolutely no interruption of application when current is transferred to and from battery. Typically UPS have a minimum of 4 milliseconds to transfer power but online UPS has no transfer time allowing constant power to your system and equipment. DS-B series offer the highest performance protection for servers, networking equipment, telecommunication systems and other critical equipment. The double conversion online topology protects against all brownouts, blackouts, voltage fluctuations and surges. True sinewave output and zero transfer time ensures perfect protection. Sinewave: Represents energy entirely concentrated at a single frequency. The more concentrated the energy is the cleaner and safer the current will be. There are four tower models and four rackmount models from DS1000B to DS3000RM to serve your every need. Amplicon.com IT and Instrumentation for industry Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com Datasheet * Zero transfer time (online) * Input voltage regulator = 80-144 VAC for 100 / 110 / 120 VAC or 120-276 VAC for 220 / 230 / 240 VAC * Smart fan speed control = saves more power and minimizes noise * 4 hours recharge time * Cold start : Allows unit to be powered without input power being available * EPO port ready : emergency power off switch * SNMP card slot available * Hot swappable / replaceable battery: continuous operation even when battery is being replaced * Extended battery pack (optional) * RS232 and USB port * Full version of OPTI-Xtreme software DS1000B 1PC+1LCD DS1500B 1PC+1LCD DS2000B 1PC+1LCD DS3000B 1PC+1LCD Amplicon.com 80 mins 90 mins 120 mins 140 mins DS1000B-RM 1PC+1LCD DS1500B-RM 1PC+1LCD DS2000B-RM 1PC+1LCD DS3000B-RM 1PC+1LCD IT and Instrumentation for industry Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com 80 mins 90 mins 120 mins 140 mins Datasheet DS1000B / DS1500B DS2000B / DS3000B DS-B ON 120V 230V 120V 230V DS2000B / DS3000B & battery pack 5-20A * DS2000B * DS2000B-RM 5-30A FUNC ENTER ON/OFF A B C DS-B RM ON ON-BAT ON-LINE 230V A) Func B) Enter C) On / Off DS2000B / DS3000B-RM Amplicon.com FAULT A) Func B) Enter C) On / Off DS1000B-RM / DS1500B-RM 120V ON-BAT BYPASS * DS3000B * DS3000B-RM 120V 120V ON-LINE 230V IT and Instrumentation for industry Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com FAULT FUNC ENTER ON/OFF A B C BYPASS Datasheet Model Name DS1000B Topology On-battery Output Waveform Number of Phase INPUT Maximum Capacity Nominal Input Voltage Input Voltage Regulation Nominal Input Frequency Input PFC Input Short Protection OUTPUT Nominal Output Voltage Output Voltage Regulation Output T.H.D High Efficiency Mode (AC to AC) Crest Factor Start on Battery Auto Restart Number of Outlets DS1500B DS2000B DS3000B True On-Line, Double Conversion Sine Wave Single Phase (2W+G) 1000VA / 700W 1500VA / 1050W 2000VA / 1400W 100/110/120Vac or 220/230/240Vac 80-144Vac or 160-276Vac 50Hz / 60Hz Auto Sensing > 0.97@Full load Circuit Breaker 3000VA / 2100W 100/110/115/120/127Vac or 208/220/230/240Vac (selectable) Rated Voltage +/- 2% < 3% T.H.D at Linear Load 92% 3:1 Yes Yes 6 Battery backup (US) 12 Battery backup (US) 4 Battery backup (IEC) 9 Battery backup (IEC320 10A×8, IEC320 16A×1) PROTECTION Data Line Surge Protection BATTERY User Replaceable Battery Typical Backup Time (Full / Half load) * Recharge Time to 90% Extended Battery Pack ADVANCED WARNINGS / DIAGNOSTICS Front Panel LEDs Audible Alarms COMMUNICATIONS INTERFACE Communication Port SNMP Manageable ENVIRONMENTAL Operation Temperature Storage Temperature Relative Humidity Audible Noise PHYSICAL Dimensions (Physical / Packing) (in) (mm) (L x W x H) Weight (Net / Gross) (lbs) (kg) RJ11 / RJ45 36V / 12V7.2AH x 3 72V / 12V34W x 3 6 / 18 min 72V / 12V7.2AH x 6 72V / 12V34W x 6 5 / 15 min < 4 Hours BP1000 BP1500 BP2000 BP3000 AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters Battery mode / UPS fault / Overload RS232 and USB Yes 0o ~40o C / 32 o~104 oF -20o~60 oC / -4o~140 oF 0~95% humidity, non-condensing < 40 dBA (at 1 meter from surface of unit) 16.5 x 6 x 9.4 / 21.5 x 11 x 14 420 x 152 x 238 / 545 x 280 x 355 39 / 42.9 37.7 / 41.6 17.1 / 19 16.5 / 18.4 CONFORMANCE Approvals 16.5 x 8.9 x 14.1 / 20.7 x 13.8 x 19.1 420 x 225 x 358 / 526 x 350 x 485 68.4 / 73.9 72.6 / 78.1 31.1 / 33.6 33 / 35.5 CE ; UL / cUL ; C-Tick, A-Tick ; GOST-R Specifications are subject to change without notice. * Backup time depends on power consumption of equipment attached and on UPS battery capacity. Numbers here are for reference only. Win Win windows windows 95/98 ME/NT Amplicon.com 2000 XP/2003 IBM IBM OS/2 IBM AIX Novell Netware Linux FreeBSD SUN Solaris HP-UX SGI Irix IT and Instrumentation for industry Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com Datasheet DS1000B-RM Model Name Topology On-battery Output Waveform Number of Phase INPUT Maximum Capacity Nominal Input Voltage Input Voltage Regulation Nominal Input Frequency Input PFC Input Short Protection OUTPUT Nominal Output Voltage Output Voltage Regulation Output T.H.D High Efficiency Mode (AC to AC) Crest Factor Start on Battery Auto Restart Number of Outlets DS2000B-RM DS3000B-RM True On-Line, Double Conversion Sine Wave Single Phase (2W+G) 1000VA / 700W 1500VA / 1050W 2000VA / 1400W 100/110/120Vac or 220/230/240Vac 80-144Vac or 160-276Vac 50Hz / 60Hz Auto Sensing > 0.97@Full load Circuit Breaker (kg) RJ11 / RJ45 36V / 12V7.2AH x 3 36V / 12V34W x 3 6 / 18 min 72V / 12V7.2AH x 6 72V / 12V34W x 6 5 / 15 min < 4 Hours BP1000-RM BP1500-RM BP2000-RM BP3000-RM AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters Battery mode / UPS fault / Overload RS232 and USB Yes 0o~40o C / 32 o~104oF -20o~60oC / -4o ~140oF 0~95% humidity , non-condensing < 40 dBA (at 1 meter from surface of unit) 16.9 x 16.7 x 3.3 / 21.7 x 21.5 x 8.1 425 x 428 x 84 / 552 x 546 x 206 41.5 / 48 40.9 / 47.4 18.4 / 21.7 18.2 / 21.5 25 x 16.8 x 3.3 / 29.5 x 21.6 x 8.6 635 x 428 x 84 / 750 x 550 x 220 69 / 74.3 71.5 / 78.5 31.6 / 33.8 32.5 / 35.7 CE ; UL / cUL ; C-Tick, A-Tick ; GOST-R Specifications are subject to change without notice. * Backup time depends on power consumption of equipment attached and on UPS battery capacity. Numbers here are for reference only. Amplicon.com 3000VA / 2100W 100/110/115/120/127Vac or 208/220/230/240Vac (selectable) Rated Voltage +/- 2% < 3% T.H.D at Linear Load 92% 3:1 Yes Yes 6 Battery backup (US) 4 Battery backup (US) 4 Battery backup (IEC) 5 Battery backup (IEC320 10A*4, IEC320 16A*1) PROTECTION Data Line Surge Protection BATTERY User Replaceable Battery Typical Backup Time (Full / Half load) * Recharge Time to 90% Extended Battery Pack ADVANCED WARNINGS / DIAGNOSTICS Front Panel LEDs Audible Alarms COMMUNICATIONS INTERFACE Communication Port SNMP Manageable ENVIRONMENTAL Operation Temperature Storage Temperature Relative Humidity Audible Noise PHYSICAL Dimensions (Physical / Packing) (in) (mm) (L x W x H) Weight (Net / Gross) (lbs) CONFORMANCE Approvals DS1500B-RM IT and Instrumentation for industry Sales: +44 (0) 1273 570 220 Website: www.amplicon.com Email: sales@amplicon.com