PVGD SERIES 15 and 20 KVA

advertisement
The Next Level in
Digital Convergence®
Tower model (with LCD display)
Capacity (VA)
CAPACITY
Capacity (W)
Voltage/ Load
INPUT
Range (0~100% load)
Frequency
Voltage (on battery)
OUTPUT
Frequency (on battery)
Transfer Time
High Efficiency mode (AC to AC)
UPS Design Technology
Output Wave Form
Harmonic distortion
Crest Factor
Surge Protection
PROTECTING
Overload Protection
AND FILTERING
SYSTEM
DISPLAY/
WARNING
BATTERY
PHYSICAL
ENVIRONMENT
CONFORMANCE
Short Circuit Protection
Visual Display (LCD model)
Audible Alarm
(Battery back-up)
UPS Fault
Communication
Type
DC Voltage (V) Battery
Typical Recharge Time to 90% Full
Management
Battery Protection
Cold Start (DC start)
Back Up Time (Tower Model)
Input Inlet
Receptacles
Tower Dimensions mm
W x D x H W/ISOTR
Net Weight kg (lb) W/ISOTR
Shipping Weight kg (lb) W/ISOTR
Operating Temperature
Storage Temperature
Altitude
Audible Noise
(1 meter form surface)
Relative Humidity
Safety
EMC (EMS/ EMI)
Warranty
www.computerpower.com
VGD SERIES - SINGLE PHASE
PVGD-15000
15000VA
10500W
PVGD-20000
20000VA
14000W
208V, 220V, 230V, 240V
180 ~ 276V
50 / 60 Hz Auto Sensing
100V, 110V, 115V, 120/ 208V, 220V, 230V, 240V +/- 2% (Selectable Output Voltage)
50 / 60 Hz +/- 0.5%
0 ms
> 97%
On-Line/ Fully digitized microprocessor controlled
Sinewave
< 3% T.H.D at linear load
3:1
IEC61000-4-5 level 3
125% for 1 minute and 150% for 10 seconds (On-line)
130% for 10 seconds and 150% for 1.5 seconds (On-battery)
UPS output cut off immediately or input fuse, circuit breaker protection
Input/output voltage, input/ output frequency, on-line mode, back up mode, battery capacity, load level
PVGD SERIES - SINGLE PHASE
Double conversion LCD
True On-Line UPS
15 KVA & 20 KVA
• True on-line technology provides all power protecon
• Pure sine-wave output with less than 3% THD
• Fully digized microprocessor controlled
• Cold start funcon (DC power on)
• Lightning and surge protecon
• Short Circuit and overload protecon
• Advanced baery management (ABM)
• Automac baery charge in UPS off mode
• Baery replacement warning
• Automac diagnoscs & baery check
• RS-232 communicaon port with monitoring soware
• SNMP / Web Card (oponal)
• Fan speed auto control when load varies
• Extended back up me with external baery bank
• Network / modem surge protecon
• UPSMON plus monitoring soware
• Emergency Power Off funcon
• Support USB communicaon
• High efficiency mode selectable
• Baery remain me display
• Mulple language LCD display
• On line output voltage selected
• LCD display front panel
• Input Power Factor Correcon
• Isolaon Transformer Included
Beep every 5 sec
Continuous beeping sound and LCD display
RS-232 Serial Port and USB (included)/ SNMP Web Card (optional)
Sealed, maintenance-free lead acid batteries
240 VDC
4 hours
Self-test, adjustable battery transfer points and alarm settings
Cut off without draining any current when battery is low
YES
About 6 min Full Load/ 15 min Half Load
Hardwire
Hardwire
342/ 863/ 905
225.0 (495.0)
246.5 (542.3)
0-40 oC/ 32~104 ºF
-20~ 50 oC/ -4~122 ºF
3500 meters max
< 55 dBA
0 ~ 95% humidity, non condensing
UL 1778, CE
IEC 61000-4, FCC Part 15; CISPR 22
2 years
Authorized Dealer
www.computerpower.com
January - 2012
The Next Level in Digital Convergence ®
The Next Level in
Digital Convergence®
Tower model (with LCD display)
Capacity (VA)
CAPACITY
Capacity (W)
Voltage/ Load
INPUT
Range (0~100% load)
Frequency
Voltage (on battery)
OUTPUT
Frequency (on battery)
Transfer Time
High Efficiency mode (AC to AC)
UPS Design Technology
Output Wave Form
Harmonic distortion
Crest Factor
Surge Protection
PROTECTING
Overload Protection
AND FILTERING
SYSTEM
DISPLAY/
WARNING
BATTERY
PHYSICAL
ENVIRONMENT
CONFORMANCE
Short Circuit Protection
Visual Display (LCD model)
Audible Alarm
(Battery back-up)
UPS Fault
Communication
Type
DC Voltage (V) Battery
Typical Recharge Time to 90% Full
Management
Battery Protection
Cold Start (DC start)
Back Up Time (Tower Model)
Input Inlet
Receptacles
Tower Dimensions mm
W x D x H W/ISOTR
Net Weight kg (lb) W/ISOTR
Shipping Weight kg (lb) W/ISOTR
Operating Temperature
Storage Temperature
Altitude
Audible Noise
(1 meter form surface)
Relative Humidity
Safety
EMC (EMS/ EMI)
Warranty
www.computerpower.com
PVGD SERIES - SINGLE PHASE
PVGD-15000
15000VA
10500W
PVGD-20000
20000VA
14000W
208V, 220V, 230V, 240V
180 ~ 276V
50 / 60 Hz Auto Sensing
100V, 110V, 115V, 120/ 208V, 220V, 230V, 240V +/- 2% (Selectable Output Voltage)
50 / 60 Hz +/- 0.5%
0 ms
> 97%
On-Line/ Fully digitized microprocessor controlled
Sinewave
< 3% T.H.D at linear load
3:1
IEC61000-4-5 level 3
125% for 1 minute and 150% for 10 seconds (On-line)
130% for 10 seconds and 150% for 1.5 seconds (On-battery)
UPS output cut off immediately or input fuse, circuit breaker protection
Input/output voltage, input/ output frequency, on-line mode, back up mode, battery capacity, load level
PVGD SERIES - SINGLE PHASE
Double conversion LCD
True On-Line UPS
15 KVA & 20 KVA
• True on-line technology provides all power protecon
• Pure sine-wave output with less than 3% THD
• Fully digized microprocessor controlled
• Cold start funcon (DC power on)
• Lightning and surge protecon
• Short Circuit and overload protecon
• Advanced baery management (ABM)
• Automac baery charge in UPS off mode
• Baery replacement warning
• Automac diagnoscs & baery check
• RS-232 communicaon port with monitoring soware
• SNMP / Web Card (oponal)
• Fan speed auto control when load varies
• Extended back up me with external baery bank
• Network / modem surge protecon
• UPSMON plus monitoring soware
• Emergency Power Off funcon
• Support USB communicaon
• High efficiency mode selectable
• Baery remain me display
• Mulple language LCD display
• On line output voltage selected
• LCD display front panel
• Input Power Factor Correcon
• Isolaon Transformer Included
Beep every 5 sec
Continuous beeping sound and LCD display
RS-232 Serial Port and USB (included)/ SNMP Web Card (optional)
Sealed, maintenance-free lead acid batteries
240 VDC
4 hours
Self-test, adjustable battery transfer points and alarm settings
Cut off without draining any current when battery is low
YES
About 6 min Full Load/ 15 min Half Load
Hardwire
Hardwire
342/ 863/ 905
225.0 (495.0)
246.5 (542.3)
0~40 ºC/ 32~104 ºF
-20~ 50 ºC/ -4~122 ºF
3500 meters max
< 55 dBA
0 ~ 95% humidity, non condensing
UL 1778, CE
IEC 61000-4, FCC Part 15; CISPR 22
2 years
Authorized Dealer
www.computerpower.com
January - 2012
The Next Level in Digital Convergence ®