NEW PRODUCT NP 194 BULLETIN Belden® Limited Combustible Cat 6 (DataTwist® Cat 6) and 5e cables (DataTwist 350 and DataTwist 5e) provide superior electrical performance and set a new standard of performance in the protection of life, property and equipment. Belden Extends Its DataTwist Limited Combustible (LC) Cable Line With A New Category 6 Offering Today’s communications demand high performance cables for data formats such as 10BaseT, 100BaseT, ATM and Gigabit Ethernet. And although these advances in information technology have delivered tremendous benefits to society, a hidden hazard lurks in the plenum spaces of our buildings, that is, high concentrations of cables made from combustible materials. To advance today’s performance needs and combustibility concerns, Belden now offers easy-toinstall, high performance cables that meet not only the TIA/EIA-568.B.2 Category 6 and 5e standards, but also the National Fire Protection Agency (NFPA) 90 standards for limited combustible cables. Setting New Performance Standards Belden DataTwist Cat 6 cable (7813LC), DataTwist 350 (1701LC) and DataTwist 5e (1585LC) Cat 5e cables utilize a fluoropolymer jacket. This helps the cables withstand the effects of heat and humidity and provides significant oil and gas resistance, resulting in outstanding electrical performance over the life of the installation. Belden applies the print legend directly on the cable jacket which presents a distinct visual advantage over competitors who supply a printed tape beneath the jacket surface. Belden DataTwist Cat 6 and DataTwist 350 cables also utilize a patented Bonded-Pair design which bonds the two conductors of a twisted pair together along the entire length of the cable. This unique bonding technology prevents performance-robbing gaps from forming between the conductors of a pair during the rigors of installation. Gaps can rob a cable of its electrical performance, resulting in reduced network efficiency for the customer and increased troubleshooting time for installers. Since Belden Bonded-Pair cables cannot gap, the customer gets the full after-installation performance that they paid for, or Installable Performance™. (Reference: Belden Technical Bulletin 66, “The Impact of Installation Stresses on Cable Performance.” ) Low Smoke, Low Flame Spread Capability Belden DataTwist Cat 6, DataTwist 350 and DataTwist 5e cables feature 100% FEP Teflon® primary insulation and jacket. They meet the full requirements for limited combustible materials as defined in NFPA 90A (Standard for the Installation of Air-conditioning and Ventilation Systems). Belden LC cables generate extremely low smoke during fire situations — 17 times less than standard CMP cables! And low smoke and less flame spread can add valuable escape time to a building evacuation. Limited combustible cables can also reduce the amount of damage to expensive electronic equipment important to mission-critical facilities like data centers. Belden LC cables also meet the proposed NEC designation for cables suitable for use in air ducts, plenums and other spaces used for environmental air. DataTwist® Limited Combustible UTP Cables Category 6 and Category 5e Description Part No. Standard UL NEC/ No. Standard Lengths Unit Wt. C(UL) CEC of Type Pairs Ft. m Lbs. kg Insulation Thickness Nominal OD Max. Max. DCR DCR (Ω/ Unbal. Inch mm Inch mm 100m) (%) Max. Max. Min. Min. Min. Cap. Freq. Atten. PSUM PSUM PSUM Input Min. ACR ELFEXT Imped. RL Unbal. (MHz) (dB/ NEXT (dB/ (pF/ (dB/ (dB) (Ω) 100m) (dB) 100m) 100m) 100m) 70.3 59.5 53.4 51.3 46.7 41.7 39.2 29.9 22.4 14.2 8.6 3.3 64.8 52.7 46.7 44.8 40.7 36.8 34.9 28.8 24.8 20.9 18.7 16.8 DataTwist • Cat 6 • 23 AWG Bonded-Pairs Solid Bare Copper • See Color Code Chart Plenum • FEP Teflon® Insulation • FEP Jacket (Available in Blue or White) 7813LC NEC: 4 Limited Combustible FHC 25/50 CMP CEC: CMP FT6 U-1000 U-304.8 28.0 12.7 .010 1000 304.8 28.0 12.7 .25 .214 5.44 8.2 3.0 49.2 Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2-1, Category 6 • U.S. Patents 5,606,151 and 5,734,126 2.0 3.8 5.4 6.0 7.6 9.6 10.7 15.5 19.9 25.3 29.2 33.0 1 4 8 10 16 25 31.25 62.5 100 155 200 250 72.3 63.3 58.8 57.3 54.3 51.3 49.9 45.4 42.3 39.5 37.8 36.3 100±15 100±15 100±15 100±15 100±15 100±15 100±15 100±15 100±15 100±22 100±32 100±32 20.0 23.0 24.5 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.3 DataTwist 350 • Enhanced Cat 5e • 24 AWG Bonded-Pairs Solid Bare Copper • See Color Code Chart Plenum • FEP Teflon Insulation • FEP Jacket (Available in Blue or White) 1701LC NEC: Limited Combustible FHC 25/50 CMP CEC: CMP FT6 4 U-1000 1000 U-304.8 24.0 10.9 .008 304.8 24.0 10.9 .20 .187 4.75 9.0 3.0 66.0 Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e • U.S. Patents 5,606,151 and 5,734,126 1 4 8 10 16 25 31.25 62.5 100 155 200 250 350 2.0 4.0 5.7 6.4 8.1 10.3 11.6 16.8 21.7 27.7 32.0 36.4 44.3 65.3 56.3 51.8 50.3 47.3 44.3 42.9 38.4 35.3 32.5 30.8 29.3 27.2 63.3 52.3 46.1 43.9 39.1 34.1 31.3 21.6 17.1 4.7 3.0 — — 60.8 48.7 42.7 40.8 36.7 32.8 30.9 24.8 20.8 16.9 14.7 12.8 9.9 100±12 100±12 100±12 100±12 100±12 100±15 100±15 100±15 100±15 100±18 100±20 100±20 100±22 20.0 23.0 24.5 25.0 25.0 24.3 23.6 21.5 20.1 19.0 19.0 18.0 17.0 1 4 10 16 31.25 62.5 100 200 2.0 4.1 6.5 8.2 11.7 17.0 22.0 32.0 62.3 53.3 47.3 44.3 39.9 35.4 32.3 27.8 60.0 49.0 41.0 36.0 28.0 19.0 11.0 1.0 60.8 48.7 40.8 36.7 30.9 24.8 20.8 14.7 100±15 100±15 100±15 100±15 100±15 100±15 100±15 100±25 20.0 23.0 25.0 25.0 23.6 21.5 20.1 15.0 DataTwist 5e • Cat 5e • 24 AWG Solid Bare Copper • Twisted Pairs • See Color Code Chart Plenum • FEP Teflon Insulation • FEP Jacket (Available in Blue or White) 1585LC NEC: Limited Combustible FHC 25/50 CMP CEC: CMP FT6 4 U-1000 U-304.8 23.0 10.5 .007 1000 304.8 23.0 10.5 .18 .184 4.67 9.38 3.0 330 Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 5e ACR = Attenuation Crosstalk Ratio • DCR = DC Resistance • ELFEXT = Equal Level Far-end Crosstalk • NEXT = Near-end Crosstalk • PSUM = Power Sum • RL = Return Loss • UTP = Unshielded Twisted Pair(s) DataTwist 7813LC, 1701LC and 1585LC cables come in Belden’s crate reel and Unreel® packaging. Fire Safety Insulation & Jacket Color Codes Pair No. Color Combination 1 White/Blue Stripe & Blue 7813LC 1701LC 1585LC 2 White/Orange Stripe & Orange 006 Blue 006 Blue 006 Blue 3 White/Green Stripe & Green 009 White 009 White 009 White 4 White/Brown Stripe & Brown For More Information: www.belden.com/cat6lc.pdf Belden Electronics Division Technical Support 1- 800-BELDEN-1 or 1- 800 - BELDEN-3 Teflon is a DuPont trademark. ©Copyright 2003, Belden Inc.