MO325-16 General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MO325-16 1SAM160000R1012 4013614302084 MO325-16 Manual Motor Starter Magnetic Only The MO325-16 manual motor starter magnetic only is a 54 mm width device with a rated operational current of Ie = 16.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter magnetic only offers a rated service short-circuit breaking capacity Ics = 60 kA at 400 VAC. Further features are the build-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory. Categories Products » Low Voltage Products and Systems » Circuit Breakers » Manual Motor Starters Products » Low Voltage Products and Systems » Control Products » Manual Motor Starters » Manual Motor Starters Ordering Minimum Order Quantity: Customs Tariff Number: Replacement Product ID (NEW): EAN: 1 piece 85362010 1SAM360000R1011 4013614302084 Container Information Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 2 Units: Package Level 2 Width: Package Level 2 Length: Package Level 2 Height: Package Level 2 Gross Weight: Package Level 2 EAN: Package Level 1 Units: 92 mm 58 mm 78 mm 0.37 kg 24 piece 280 mm 395 mm 210 mm 0.61 kg 4013614495045 1 piece Dimensions Product Net Height: Product Net Depth: Product Net Weight: Product Net Width: 87.5 mm 75.5 mm 0.34 kg 54 mm Technical Rated Ultimate Short-Circuit Breaking Capacity (Icu): Rated Instantaneous Short-Circuit Current Setting (Ii): Setting Range: Rated Operational Voltage: (230 V AC) 100 kA (400 V AC) 60 kA (440 V AC) 40 kA (500 V AC) 25 kA (690 V AC) 4 kA 240 A None Main Circuit 690 V AC Main Circuit 440 V DC Rated Operational Current (Ie): 16 A Rated Operational Current AC-3 (Ie): 16 A Rated Frequency (f): Main Circuit 50 Hz Main Circuit 60 Hz Rated Impulse Withstand Voltage Main Circuit 6 kV (Uimp): Rated Insulation Voltage (Ui): 690 V Power Loss: at Rated Operating Conditions per Pole 1.7 W Number of Poles: 3 Conventional Free-air Thermal Current (Ith): Degree of Protection: Pollution Degree: Electrical Durability: Mechanical Durability: Connecting Capacity Main Circuit: Tightening Torque: Wire Stripping Length: Recommended Screw Driver: Mounting Position: Actuator Type: Contact Position Indication: Mounting on DIN Rail: Standards: Remarks: Rated Service Short-Circuit Breaking Capacity (Ics): Main Circuit 16 A IP20 3 50000 cycle 100000 cycle Flexible with Ferrule 1/2x 0.75 ... 4 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm² Flexible 1/2x 1 ... 6 mm² Rigid 1/2x 1 ... 6 mm² Main Circuit 1.4 N·m Main Circuit 10 mm M3.5 Pozidriv 2 Position 1 to 6 Rotary Handle ON / OFF TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 508 CSA 22.2 No. 14 For overload protection of the motors, an appropriate thermal or electronic overload relays must be used (230 V AC) 100 kA (400 V AC) 60 kA (440 V AC) 40 kA (500 V AC) 25 kA (690 V AC) 4 kA Environmental Ambient Air Temperature Compensation: Maximum Operating Altitude Permissible: Resistance to Shock acc. to IEC 60068-2-27: Resistance to Vibrations acc. to IEC 60068-2-6: RoHS Status: Ambient Air Temperature: No 2000 m 11 ms Pulse 15g 5g / 10 ... 150 Hz Following EU Directive 2002/95/EC August 18, 2005 and amendment Around the Enclosure 0 ... +40 °C Operation -25 ... +50 °C Storage -50 ... +80 °C Technical UL/CSA Horsepower Rating UL/CSA: Ampere Rating UL/CSA: Connecting Capacity Main Circuit UL/CSA: Tightening Torque UL/CSA: Maximum Operating Voltage UL/CSA: (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 10 Hp 16 A Flexible 1/2x 14-8 AWG Stranded 1/2x 14-8 AWG Main Circuit 14 in·lb Main Circuit 600 V AC Certificates and Declarations (Document Number) Instructions and Manuals: CB Certificate: CCC Certificate: cUL Certificate: cULus Certificate: Data Sheet, Technical Information: Declaration of Conformity - CE: DNV Certificate: GL Certificate: GOST Certificate: LR Certificate: RINA Certificate: 1SAM107011P0003 1SAA918000-2002 1SAA918000-3806 cUL_E137861 E137861 2CDC130002C0206 1SAD938506-0037 1SAA918000-0305 1SAA918000-0403 1SAA918000-2703 1SAA918000-0503 1SAA918000-0803 RMRS Certificate: RoHS Information: UL Certificate: 1SAA918000-0703 1SAA918001-4401 UL_E137861 Classifications ETIM 4: ETIM 5: ETIM 6: eClass: UNSPSC: Object Classification Code: EC000074 - Motor protective circuit-breaker EC000074 - Motor protective circuit-breaker EC000074 - Motor protection circuit-breaker 7.0 27370401 39121521 F