Brochure

advertisement
DELTA
Energy DC - Rectifier
Delta is a DC power supply range with all capabilities required for charging lead (Pb) and nickel cadmium
(NiCd) batteries while optimizing their service life.This ranges covers all normal DC voltages from 12 to 48Vdc
and provides the right power. They are suitable for all industrial applications including system with long
lasting battery.
DELTA modules have been designed for charging all normal types of battery. Thanks to the easy interface status, you
can process a lot of adjustements and operating status is available. Several protections and functions are integreted
to make service and installation easier and faster. They guarantee reliable use and extend battery service life even if
it used in restrictive and difficult environnement. DELTA modules can also be configured in DC power supply, with an
adjustable output voltage. They can also be integrated on a support plate, in box or in electrical panels to provide DC
power supply with backup for process control systems, signaling devices, relays or solenoïd valves.
Quick and safe installation on
switchboards.
Adjustable mounting on slots.
DIN rail mounting (for Delta 300).
Plug-in connectors for facilitating
cabling.
Built-in protections against defects and
failures (overload, short circuits, change
of polarity, output overvoltage, etc.).
Natural convection.
Max operating temperature : 50°C.
Simple, expandable and flexible
configuration.
Easy programming by switches (mode
of operation, type of battery).
Built-in boost function for rapid battery
charging.
Can
be mounted in parallel with
coupling diodes (3 modules at the most
) for increasing power or redundancy.
Monitoring of default included.
For more details.
See technical documentations available on the website www.aees.fr.
DELTA
Code
Voltage
Reference
Input (Vac)
Output* (Vdc)
Current
Mecanics
Output (A)
Dimensions
6014115
DELTA 300 12 10
12 V (10-15)
10
6014113
DELTA 300 24 10
24 V (10-30)
10
6014114
DELTA 300 48 05
48 V (15-60)
5
6013112
DELTA 600 12 20
12 V (10-15)
20
6012124
DELTA 600 24 20
24 V (10-30)
20
6012125
DELTA 600 48 10
48 V (15-60)
10
187 à 264 V
47 à 63 Hz
IP 20
H : 135 mm
L : 103 mm
P : 135 mm
1 Kg
IP 20
H : 282 mm
L : 202 mm
P : 75 mm
2.6 Kg
*by external potentiometer
Functions
The test allows to prevent back up interruption due to a wire or a battery link cut or defective battery.
The operator can carry out this test any time, by strapping connector terminals.
Although Delta chargers are pre-adjusted for standard batteries, their output voltage can be adjusted
to up to 125% of nominal voltage by using the potentiometer on the front of the unit.
To accelerate charging, it is useful to set the voltage at a higher level for several hours. Delta chargers
are equipped with a Boost feature which rises the charging voltage by 3.8%. This function is activated
by strapping connector terminals.
Battery Test
Output voltage
adjustment
Boost
Current and voltage control by external The voltage on Delta rectifier may be adjusted by an external potentiometer over a range from 10
to15V for 12V rectifier, from 10 to 30V for 24 V rectifier and from 15 to 60V for 48V rectifier.
potentiometer
Indicators
Charger status is indicated by 2 Leds and a general defect relay.
CF Option
Available in cabinet IP31, dimensions : 450 x 497 x 253 mm (HWD)
General Data
DELTA 300
DELTA 600
Standard efficiency
83% à 90%
Input power factor
> 0.95
Voltage adjustment
± 1%
Dynamic adjustment
< 5% / 5ms (de 100%to 10% de In)
Effective residual ripple ratio
< 0.2%
Operating temperature
0°C to + 50°C
Storage temperature
0°C to + 40°C (500W à +50°C)
- 45°C to + 85°C
Cooling
Natural convection
Accessorie
6 015 524
Same footprint than CN-D with dedicated support for DELTA 300
Standards
Product : NF C 58-311 and NF 61204
DBT : NF EN 60950-1 §2.10, §5.2 - NF EN 50178
Product TBTS : NF C 15-100
CEM : NF EN 61000-3-2, NF EN 61000-6-2, NF EN 61000-6-4
Compliance
Emerson Network Power IS SAS
30 avenue Montgolfier / BP90
69684 Chassieu Cedex France
T +33 (0) 4 72 47 63 77 / F +33 (0) 4 78 40 13 94
Aees@Emerson.com / www.Aees.fr
EmersonNetworkPower.com
Emerson. Consider it Solved and Emerson
Network Power are trademarks of Emerson
Electric Co. or one of its affiliated companies.
All the other marks are the property of their
respective owners. ©2015 Emerson Electric Co.
PDS.EL-DEL-FR
E mer so n . co n s ide r it so lved ™ .
Les informations contenues dans ce document sont fournies à titre indicatif et ne peuvent être utilisées contractuellement. Notre société a une politique de développement et d’amélioration continue de ses produits, et par conséquent se réserve
le droit de modifier toute information sans préavis. Crédits Photos : Georges Rivalain, iStockPhoto, Fotolia.
Energy DC - Rectifier
Download