Eight Channel Strain Gage SG-8 Plate with ID Capability and SG/LX8-S-ID Adapter GENERAL DESCRIPTION The SG-8 plate provides an interface between a RJG Eight Channel Strain Gage Adapter and up to eight RJG strain gage multichannel sensors. The SG-8 simplifies and decreases the footprint of multi-sensor applications and identifies the mold for easy software setup. Technical Specifications Max Temperature Connectors Max Temperature Sensor head Number of Channels Accuracy +85 C [+185 F] +120 C [+250 F] 1 - 8 Strain Cage Sensors, 1 Mold ID E1% System Components A B A SG/LX8-S-ID Lynx Eight Channel Strain Gage Adapter B C-SG/LX8-S-0.5M, 1M, 2M Eight Channel Connection Cable C SG-8 Eight Channel Sensor Plate D MCSG-B-127-125, 500, 2000 Multichannel Strain Gage Sensor Sensor Ordering Length C D Sensors available in 6 inch (15cm) increments Make sure that the Ground Potential of the mold is the same as the Ground used by the eDART™. (This can be done by using a multimeter to measure the DC and AC voltage difference between these two locations.) Make sure that the Adapter and any connecting cables are out of the way of any sources of static such as feeder tubes and material hoppers. RJG, Inc. E1.0 1 Multi-Channel Strain Gage Pocket for SG-8 Plate Installation Plate Dimensions Pocket Cutout C E A B D A Description This dimension is critical for optimal performance RJG, Inc. E1.0 A Ejector, Clamp or Other Plate B Pocket for Sensor Connectors C Cable Channel D Wall Provides Support for Compression of Connectors E Break Edge 2 Multi-Channel Strain Gage Sensor and Plate Installation Attach Sensors to SG-8 Plate The sensor connectors are keyed to ensure the connector is aligned properly with the plate. A The top of the module is indicated by a larger gap on the board. The higher portion of the sensor plug-in corresponds to this gap. A A A Attach SG-8 Plate to Mold Make sure the plate is fully tightened down, as this compresses the connectors and ensures a good electrical connection. B C C Make sure that all cables are properly secured in the channels before attaching the retainer or cover plate. B Mount Adapter to Platen NOTES: The Adapter must be mounted on a grounded structure (such as a mold in the press or platen) but preferably to the machine frame or control panel to ensure proper operation. RJG, Inc. E1.0 3 Multi-Channel Strain Gage Connect and Configure Connect Plate to Adapter The multichannel connector cable is attached to the mold using two captive M5 screws. These must be properly tightened using an Allen wrench to prevent the screws from loosening during use. Failure to properly tighten the screws can cause damage to the connector. Configure Sensors In the eDART™ software Sensor Locations page, enter the sensor model on the Setup page for each channel. If multiple plates are used on a single mold, the unique serial number of each is matched to corresponding plate number in the eDART™ software. The serial number also allows the eDART™ to automatically identify the mold and recall the correct setup each time the plate is connected to the adapter. (See below) This allows a single strain gage adapter to be mounted on a single molding machine and still be used with multiple molds. Version 9.xx Version 10.xx RJG, Inc. E1.0 For further Information please contact RJG Customer Support at 231-947-3111 ext. 170 4 Multi-Channel Strain Gage