TECHNICAL DATA SHEET TELCO 75 OHM COAX 0.4-2.4-ESFES-4.1-H PTR 229/45 and SI 260600501 code version date page 43113 2 2001-04-20 1/3 3. 2. 1. APPLICATION For use as intra- or inter-rack cabling for telecommunication systems. Indoor use only. CONSTRUCTION 7. 1. Conductor Material Diameter of conductor 2. Inner dielectric Material Diameter over inner dielectric 3. Outer dielectric Material Diameter over outer dielectric 4. Inner braid Material Nominal diameter of wires Coverage Nominal diameter over braid 5. Foil Material 6. Outer Braid Material Nominal diameter of wires Coverage Nominal diameter over braid 7. Sheath Material Diameter over sheath Minimum sheath thickness 6. 5. 4. Soft annealed silvered copper 0.40 ± 0.01 mm (AWG 26) FEP 0.82 ± 0.05 mm Polyethylene 2.42 +/- 0.1 mm Soft annealed copper 0.10 mm ≥ 90% 2.87 mm Copper Soft annealed copper 0.10 mm ≥ 90% 3.40 mm FRNC 4.07 ± 0.15 mm 0.30 mm REQUIREMENTS AND TEST METHODS Electrical: DC Resistance of inner conductor Capacitance @ 800 Hz ≤ 145 Ω/km 64.3-67.8 pF/m © Belden Wire & Cable B.V. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner TECHNICAL DATA SHEET TELCO 75 OHM COAX 0.4-2.4-ESFES-4.1-H PTR 229/45 and SI 260600501 Impedance @ 20 MHz Attenuation @ 10 MHz Reflection @20-400 MHz @400-860 MHz FEXT @ 1 – 100 MHz Dielectric strength Test voltage over jacket Insulation resistance of dielectric at 500 Vdc Mechanical and physical: Conductor Tensile strength Elongation at rupture Dielectric Tensile strength 1st and 2nd layer Elongation at rupture Shrinkage of 100mm after 15 minutes at 100° C Sheath Tensile strength Elongation at rupture Tensile strength after 7 days 80° C Elongation at rupture after 7 days 80° C Limited Oxygen Index Corrosivity of fire gasses Conductivity pH value code version date page 43113 2 2001-04-20 2/3 75 +/- 2 Ω ≤ 5.2 dB/100m ≥ 20 dB (≤ 10%) ≥ 16 dB (≤ 16%) ≥ 80 dB at 100m 1.5 kVdc during 1 minute 2.0 kVac ≥ 104 MΩ*km ≥ 200 N/mm² ≥ 15% ≥6.5 N/mm² ≥ 100% ≤ 3% ≥ 9.0 N/mm² ≥ 100% ≥ 0.8 of unaged value ≥ 0.8 of unaged value ≥ 30 ≤ 100 µS/cm ≥ 3.5 Cable Resistance to flame propagation Temperature range operating and processing Temperature range storage Bending/setting radius IEC 332-1 -20˚ C to +70˚ C -40˚ C to +70˚ C 10*D/5*D MARKING For colour code 2934: colour of sheath: grey ‘BELDEN VENLO HOLLAND H127 YYYY COAX 0.4/2.4/4.1 ES COMCODE 847766081’ + length indication in metres. YYYY = year of manufacture For colour code 2280: colour of sheath: grey ’83 5134 KPN TELECOM YYYY BELDEN VENLO HOLLAND COAX 0.4/2.4/4.1 ES’ + length indication in metres. YYYY = year of manufacture PACKAGING On returnable reels (E500) with a nominal length of 500 ± 25 m On non-returnable reels (E315) with a nominal length of 500 ± 25 m In rings with a nominal length of 200 m © Belden Wire & Cable B.V. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner TECHNICAL DATA SHEET TELCO 75 OHM COAX 0.4-2.4-ESFES-4.1-H PTR 229/45 and SI 260600501 code version date page 43113 2 2001-04-20 3/3 In non-returnable boxes with a nominal length of 200 m. Each reel, ring and box is labelled with the following data: - Belden Logo - Belden code number - Item description - Length on the reel - Date of manufacture. © Belden Wire & Cable B.V. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner