Type SP-OS Multiple Shielded Pairs or Triads - Overall Shield 300 Volts - 105°C Rating Bare Stranded Copper Conductors Okoseal Insulation Tinned Stranded Copper Group Drain Wire double faced Aluminum/Polyester Backed Tape Group Shield Twisted, Shielded Pairs/Triads Communication Wire Double Faced Aluminum/Polyester Backed Tape Tinned Stranded Copper Drain Wire Rip Cord Inner Black Okoseal Jacket Galvanized Steel Wire Armor Outer Black Okoseal Jacket Bare soft annealed copper, Class B, 7-strand concentric per ASTM B-8. Flame-retardant Okoseal® (PVC) per UL Standard 13 and 2250, 15 mils nominal thickness, 105°C temperature rating. Pigmented black and white in pairs, black, red and white in triads; white conductor numerically printed for group identification. Aluminum/synthetic polymer backed tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, two sizes smaller than the conductor. All group shields are completely isolated from each other. 22 AWG, solid, bare copper conductor, 12 mils nominal flameretardant Okoseal insulation, 105°C temperature rating. Pairs or triads assembled with lefthand lay. Flame-retardant, non-wicking fillers included where required to provide a round cable. Aluminum/Polyester backed tape overlapped to provide 100% coverage, and a 7strand tinned copper drain wire, same size as conductor. Black, flame-retardant, low temperature Okoseal per UL Standard 13 and 2250. A rip cord is laid longitudinally under the jacket to facilitate removal. A single serving of soft annealed galvanized steel wires applied with a left-hand lay and 90% minimum coverage. Black, flame-retardant, low temperature Okoseal per UL Standard 13 and 2250. UL Listed as ITC/PLTC - Instrument Tray Cable/Power Limited Tray Cable for use in accordance with Article 727 and Article 725 of the National Electrical Code. The cable core complies with UL 2250 and UL 13 for PLTC, CL2 and CL3. Okonite single wire armor (SWA) Type SP-OS (Pair/triad - Individual and Overall Shield) instrumentation cables are designed for use as instrumentation, process control, in ITC nonclassified or labeled circuits up to 150 volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where maximum shielding against external interference is required, as well as shielding UL R among groups, particularly where the cable may be subject to abnormally high current or voltage interference; indoors or outdoors; in wet or dry locations with conductor operating temperatures up to 105°C; in cable trays; in raceways; supported by a messenger wire; under raised floors; for direct burial. Suitable Class I, Division 2, Class II, Division 2, or Class III, Division 2 hazardous locations. Also for use as power-Limited fire protective signaling cable (FPL) per NEC Code 760. The isolated individual shields over each pair, when properly grounded, prevent crosstalk or capacitive coupling between adjacent pairs which occurs with ac signals, particularly the pulse type. The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment. The wire armor provides excellent longitudinal strength for use as a messenger cable or for support in vertical drops (NEC Section 300-19) and provides the physical protection against mechanical damage. For dc service in wet locations X-Olene® insulation is recommended. • Sunlight resistant. • Excellent electromagnetic shielding. • Oil resistant. • Individual pairs or triads are completely isolated. • Maximum noise rejection. • Communication wire included in each cable for voice communication during installation or instrument calibration. • Excellent longitudinal strength. • Lower installed system cost than conduit or EMT systems. • Excellent Cut-through resistance. • Suitable for IEC/BS application. • OSHA Acceptable. Type SP-OS Multiple Shielded Pairs or Triads - Overall Shield 300V - 105°C Rating UL = R 261-10-8204 261-10-8208 261-10-8210 4 8 10 50 50 60 .42 .56 .66 38 x 18 34 x 18 31 x 16 .53 .65 .78 50 50 60 .64 .76 .92 .32 .45 .66 355 474 693 394 513 757 261-10-8212 261-10-8216 261-10-8220 12 16 20 60 60 60 .69 .76 .82 32 x 16 35 x 16 31 x 14 .81 .88 .98 60 60 60 .94 1.01 1.12 .69 .80 .99 736 842 1103 800 906 1183 24 36 50 70 70 70 .94 1.06 1.21 34 x 14 29 x 12 34 x 12 1.10 1.26 1.42 70 70 70 1.25 1.41 1.57 1.22 1.56 1.93 1283 1801 2201 1389 1917 2344 261-10-8224 261-10-8236 261-10-8250 20(7X) 261-15-8204 261-15-8212 261-15-8216 4 12 16 50 60 60 .48 .77 .79 29 x 18 34 x 16 30 x 14 .58 .89 .95 50 60 60 .69 1.03 1.09 .37 .83 .93 388 830 1103 427 894 1183 261-15-8224 261-15-8236 24 36 70 70 .99 1.11 36 x 14 31 x 12 1.15 1.32 70 70 1.30 1.47 1.33 1.70 1462 2068 1568 2184 261-10-8304 261-10-8308 261-10-8310 4 8 10 50 50 60 .49 .61 .73 30 X 18 29 X 16 35 X 16 .60 .73 .86 50 50 60 .70 .84 .99 .38 .55 .77 405 648 817 444 712 881 261-10-8312 261-10-8316 261-10-8320 12 16 20 60 60 70 .75 .83 .94 35 X 16 31 X 14 35 X 14 .88 .99 1.10 60 60 70 1.01 1.13 1.27 .80 1.00 1.27 864 1148 1370 928 1228 1450 24 36 50 70 70 80 1.04 1.19 1.42 29 X 12 33 X 12 39 X 12 1.25 1.40 1.63 70 70 80 1.40 1.55 1.80 1.54 1.89 2.54 1782 2176 2772 1898 2319 2959 261-10-8324 261-10-8336 261-10-8350 18(7X) 261-15-8304 261-15-8312 261-15-8316 4 12 16 50 60 60 .54 .80 .89 32 X 18 30 X 14 33 X 14 .64 .96 1.05 50 60 60 .75 1.09 1.18 .44 .93 1.09 453 1133 1319 492 1213 1399 261-15-8324 261-15-8336 24 36 70 70 1.10 1.24 31 X 12 35 X 12 1.32 1.45 70 70 1.47 1.61 1.70 2.04 2047 2537 2163 2680 261-10-8404 261-10-8408 261-10-8410 4 8 10 50 60 60 .54 .71 .82 37 x 18 33 x 16 31 x 14 .63 .83 .98 50 60 60 .74 .96 1.12 .43 .72 .98 477 827 1126 516 891 1206 261-10-8412 261-10-8416 261-10-8420 12 16 20 60 70 70 .85 .98 1.06 31 x 14 35 x 14 30 x 12 1.06 1.14 1.27 60 70 70 1.14 1.29 1.43 1.02 1.31 1.61 1192 1451 1931 1272 1557 2047 24 36 50 70 80 80 1.17 1.37 1.57 38 x 12 38 x 12 44 x 12 1.38 1.58 1.78 70 80 80 1.54 1.75 1.95 1.86 2.41 2.99 2177 2791 3468 2320 2978 3734 261-10-8424 261-10-8436 261-10-8450 16(7X) 261-15-8404 261-15-8412 261-15-8416 4 12 16 50 70 70 .58 .97 1.02 35 x 18 34 x 14 29 x 12 .68 1.13 1.23 50 70 70 .79 1.28 1.38 .49 1.29 1.50 542 1440 1948 581 1546 2064 261-15-8424 261-15-8436 24 36 80 80 1.27 1.43 36 x 12 41 x 12 1.48 1.64 80 80 1.66 1.82 2.16 2.60 2632 3319 2775 3585 Conductor Resistance, nominal .............ohms/1000 ft. @20°C 20 AWG....................................................................... 10.4 18 AWG......................................................................... 6.5 16 AWG......................................................................... 4.1 Insulation Test Voltage (spark test) ..............5000 Volts ac Dielectric Test Voltage.........................1500 Volts ac for 15 sec. Insulation Resistance Constant @60°F minimum (natural material typical value) ......2000 Megohms-1000 ft. Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C 20 AWG....................................................................... 20.8 18 AWG....................................................................... 13.0 16 AWG......................................................................... 8.2 Mutual Capacitance (PF/ft.)* #20 ................................................................................. 59 #18 ................................................................................. 68 #16 ................................................................................. 76 *Typical Value C/05030516 = area for calculation of cable tray fill in accordance with NEC Section 318-8 Aluminum Loxarmor available on special order. Cut lengths of 1000 feet or longer are subject to a tolerance of ± 10%; less than 1000 feet ± 15%. THE OKONITE COMPANY Ramsey, New Jersey 07446