Wiring Instructions

advertisement
Wiring Instructions
™
Input Devices by Draper
Caution
1 Make sure power is disconnected before installing controls.
2 Maximum surrounding air temperature 70 degrees Celsius.
3 All devices and shades must be plugged into the IntelliFlex BUS line
before you begin programming. These devices must be programmed using
Draper’s IntelliFlex Programming Software, available for download at:
www.draperinc.com/ProTools.htm. You will need a Draper dealer number to
gain access and download the software.
DCI Input
Converts dry contacts into system commands to which any control on the BUS line can respond. It can work with up to 6 (DCI6) or 12 (DCI12)different
contact closures.
Motor Output
Max. 12 AWG 3+1 Ground Cable
Line Voltage 110V
Up - Black
Common- White
Down - White
Ground - Green
Building Power
Max. 12 AWG 2+1 Ground Cable
Line Voltage 110V
Hot - Black
Neutral - White
Button 6
COM
Button 5
Button 4
S C S
W O W
1 M 2
Ground - Green
COM
Button 3
Button 2
COM
Button 1
Micro USB
Connection
9 pin, plugable screw
terminal connector
LED Indicators:
Green - Power
Sun Sensor/Timer
Sensor is designed to have an up and down threshold which is user defined during programming. There is also a built-in delay mode for passing clouds. The
timer is also set at programming. One enters the time and structures of the time zone.
Motor Output
Max. 12 AWG 3+1 Ground Cable
Line Voltage 110V
Up - Black
Common- White
Down - White
Ground - Green
Building Power
Max. 12 AWG 2+1 Ground Cable
Line Voltage 110V
Hot - Black
Neutral - White
Ground - Green
S C S
W O W
1 M 2
Wind +
Wind Sun Ground
Sun -
Wind Sensor
Brightness Sensor
Sun +
Micro USB
Connection
5 pin, plugable screw
terminal connector
RS-232/485 Bridge
The RS 232/485 serial input allows these types of serial commands to operate controls on the bus line. There is no GUI. This type of control is for automation
system integration.
Motor Output
Up - Black
Max. 12 AWG 3+1 Ground Cable
Line Voltage 110V
Common- White
Down - White
Ground - Green
Building Power
Max. 12 AWG 2+1 Ground Cable
Line Voltage 110V
Hot - Black
Neutral - White
Ground - Green
®
RS 232 Connection
Straight Thru Configuration
DB9 Connector
S C S
W O W
1 M 2
Micro USB
Connection
RS 485 Connection
3 pin, plugable screw
terminal connector
+ Positive
Twisted Pair
- Negative
Ground
LED Indicators:
Green - Power
Red - RS-232 command receive
Copyright ©2013 Draper Inc. Form IntelliFlex InputDevices-Gen3_Inst13-R3 Printed in U.S.A.