preset counter CCX

advertisement
Preset Counters
CC
02
02
CE CK CI
CE CK CI
CCX-550/ATX AC 220-240 VA
CCX-350/ATX AC220-240VA
SWISS MADE BY COMAT AG CH-3076 WORB
SWISS MADE BY COMAT AG CH-3076 WORB
Electronic Preset Counters of the series CC point out the following
main characteristics:
•
•
•
•
•
Plug in Preset Counters with 2 change-over contacts 6 A, 250 V A
Touch contact with digital display (CCX-550)
11 pin submagnal plug as specification IEC 67-1-18 a
Suitable for front panel mounting with accessory FZ - 23
Digital value display (CCX-550) and LED indication of the relay
function
Kühn Controls AG
Vertriebsbüro Deutschland
Gräfenhäuser Str. 14
D-75305 Neuenbürg
Tel.: +49- (0)7082-940000
Fax: +49- (0)7082-940001
eMail: sales@kuehn-controls.de
www.multicomat.net
CC / 6.02 E
This issue replaces all previous issues. Availability, errors and specifications subject to change without notice.
Preset Counters with Display
CCX-550
SWISS MADE BY COMAT AG
Data at Tamb = 25°C and Vnom
Type
Decades /Select
Decades /Display
3/0–999
3
CCX-550
Max. counting frequency
200 Hz
02
CE CK CI
Supply, Power Consumption, Type
AC 50/60 Hz
DC
U min – U max
I max
AC 220–240VA
190– 265V a
11mA
AC 110–120VA
90–140Va
15 mA
UC 24–48VU
19–60V a
110 mA
U min – U max
I max
Type
CCX-550/ATX
CCX-550/ANP
19–60Vd
110 mA
CCX-550/UFK
Example of order: 1 preset counter CCX-550/ATX
CCX-550/ATX AC220-240VA
SWISS MADE BY COMAT AG CH-3076 WORB
Wiring Diagramm
Timing modes
U
1
n
1
C
R
CE
Q
PNP
Q is active after reaching the preselected number of pulses.
Q and C can be reset with the reset button.
U
1
n
1
C
R
CK
Q
Q is active during the preselected number of pulses
and can only be reactivated after a reset.
Q and C can be reset with the reset button.
+
COUNT
NAMUR
C
R RESET
U
1 n 1
1
n
C
R
CI
Q
t
ON
OFF
8
Q is active for t75. ..125ms on the preselected pulse.
The cycle starts again at the beginning.
Q and C can be reset with the reset button.
7 6 5
4
OUTPUT
Q
U = Voltage
C = Count
R = Reset
Q = Output relays
A2
A1
9 10 11 1 2 3
A+
A
General
Technical data
Output circuit
Display
3-digit, 7-segment LEDs
Load of triggering contact C/R
3mA/<15V
Switching current max.
Switching voltage max.
Breaking capacity
Mechanical life
Contact material
6A
250V
AC: 1500VA; DC: ... 250W
30 million operations
Ag Ni 90/10
Technical data
These values are valid for ohmic load or for inductive loading with spark arrest.
Other contact material on request.
≥ 2,5ms
≥ 35ms
50ms
Climate
Ambient temperature range
Storage temperature range
10–95% relat. humidity not condensing
– 25… +60°C
– 25… +80°C
Transient voltage protection
Specifications
Protection/case material
Weight incl. packing
IEC 255.4. app. E, class III
VDE 0435/0110 Gr.C, CE
IP 40/Noryl SE1 to UL 94V-1
approx. 180g
Dimensions
Enclosure S3
72
Triggering time C
Triggering time R
Reset time
5
38
42
FZ-23
75
78
FS-23
4,5
9
Front mounting accessory FZ-23 (front panel aperture: 38,5x70 +– 00,5 mm, front panel thickness
max. 3mm). Transparent front cover FS-23 (part of the scope of delivery.)
2
CC/6.02 E
This issue replaces all previous issues. Availability, errors and specifications subject to change without notice.
Preset Counters
CCX-350
SWISS MADE BY COMAT AG
Data at Tamb = 25° C and Vnom
Type
Decades /Select
Decades /Display
3/0–999
–
CCX-350
Max. counting frequency
200 Hz
02
CE CK CI
Supply, Power Consumption, Type
AC 50/60 Hz
DC
U min – U max
I max
AC 220– 240VA
190– 265Va
11mA
AC 110–120VA
90–140Va
15 mA
UC 24– 48VU
19–60V a
110 mA
U min – U max
I max
Type
CCX-350/ATX
CCX-350/ANP
19– 60V d
110 mA
CCX-350/UFK
Example of order: 1 preset counter CCX-350/ATX
CCX-350/ATX AC220-240VA
SWISS MADE BY COMAT AG CH-3076 WORB
Wiring Diagram
Timing modes
U
1
n
1
C
R
CE
Q
PNP
Q is active after reaching the preselected number of pulses.
Q and C can be reset with the reset button.
U
1
n
1
C
R
CK
Q
Q is active during the preselected number of pulses
and can only be reactivated after a reset.
Q and C can be reset with the reset button.
+
COUNT
NAMUR
C
R RESET
U
1 n 1
1
n
C
R
CI
Q
t
ON
OFF
8
Q is active for t75...125ms on the preselected pulse.
The cycle starts again at the beginning.
Q and C can be reset with the reset button.
7 6 5
OUTPUT
Q
U = Voltage
C = Count
R = Reset
Q = Output relays
A2
Load of triggering contact C/R
A1
9 10 11 1 2 3
A+
A
Technical data
4
General
Technical data
Output circuit
3mA/<15V
Switching current max.
Switching voltage max.
Breaking capacity
Mechanical life
Contact material
6A
250V
AC: 1500VA; DC: ... 250W
30 million operations
Ag Ni 90/10
These values are valid for ohmic load or for inductive loading with spark arrest.
Other contact material on request.
≥ 2,5ms
≥ 35ms
50ms
Climate
Ambient temperature range
Storage temperature range
10–95% relat. humidity not condensing
– 25… +60°C
– 25… +80°C
Transient voltage protection
Specifications
Protection/case material
Weight incl. packing
IEC 255.4. app. E, class III
VDE 0435/0110 Gr.C, CE
IP 40/Noryl SE1 to UL 94V-1
approx. 180g
Dimensions
Enclosure S3
72
Triggering time C
Triggering time R
Reset time
5
38
42
FZ-23
75
78
FS-23
4,5
9
Front mounting accessory FZ-23 (front panel aperture: 38,5x70 +– 00,5 mm, front panel thickness
max. 3mm). Transparent front cover FS-23 (part of the scope of delivery.)
CC/6.02 E
3
Accessories
EC-11
3
4
LH-1
L-16
12345
S+S, wieland
9
8
7
5
3
4
34
32
24
22
14
12
EC-11
16
30
4
8
75
A2-CONNECTOR
FOR PLUG-IN
MODULES
A1
A2
11
10
6
1
15
3,2
29,5
C-A2
10 A
18
28
10
C-A2
for
M3
SC-3
SD -1
A2
31
21
11
A1
10
11
6
1
2
24.2
M3
FOR M4
TEST
32 24 21 22 12
6
for
M4
4
max 40
7 6 5
CS-11
10A 10A
400V 300V
Listed
10A
400V
8
34 A2 31 11 A1 14
9 10 11 1
FOR PLUG-IN
MODULES
2
3
CODING
CA-11
LABEL SL-36
TS 35
5
68
7
8
Relay socket with screw, connections
for panel or DIN mounting-snap fit
8
9
CS-11
Relay socket with screw, connections
for panel or DIN mounting-snap fit
LABELS
Relay socket with screw, connections
for panel or DIN mounting-snap fit
SWISS MADE BY COMAT AG
62
C11A
This issue replaces all previous issues.
Availability, errors and specifications subject to change without notice.
ø 5,3
S3
Case
38
4
2 3
22
38
38
4
4
20
20
RG-23
11 PGL Relay socket for chassis mounting
11 PGF Relay socket for fasten connectors
(solder tags: 3,8x0,8 mm)
(2xAMP 2,8x0,8 DIN 46247)
Surface mounting case with built-in
relay socket (protected connection terminals)
125
39
27
39
27
RG-23
1,5
15
38
HF-24
6,5
38
10
Retaining clip made of special spring steel
suitable for all relay sockets
1,5
3,5
94
4
4,5
3,5
Faston
2,8x0,8
(2x)
4,5
4
38x 72
4,5
3 24
CS-11
67
3
6,5
11
10
50
FS-23
Transparent cover
(always included with the relay)
FZ-23
Front of panel mounting accessory
comprising 2 front frame parts ➀ and 2 retaining clips ➁
97
46
0,6
14
35
Gehäuse
case, boîtier
0,5
0
+0,5
0
38
,5 +
S3
70
2
3
2
1
mi
n.
4
CC/6.02 E
3
48
.
1..
Example of order: 1 relay socket type CS-11
3
1
2
Download