Preset Counters CC 02 02 CE CK CI CE CK CI CCX-550/ATX AC 220-240 VA CCX-350/ATX AC220-240VA SWISS MADE BY COMAT AG CH-3076 WORB SWISS MADE BY COMAT AG CH-3076 WORB Electronic Preset Counters of the series CC point out the following main characteristics: • • • • • Plug in Preset Counters with 2 change-over contacts 6 A, 250 V A Touch contact with digital display (CCX-550) 11 pin submagnal plug as specification IEC 67-1-18 a Suitable for front panel mounting with accessory FZ - 23 Digital value display (CCX-550) and LED indication of the relay function Kühn Controls AG Vertriebsbüro Deutschland Gräfenhäuser Str. 14 D-75305 Neuenbürg Tel.: +49- (0)7082-940000 Fax: +49- (0)7082-940001 eMail: sales@kuehn-controls.de www.multicomat.net CC / 6.02 E This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Preset Counters with Display CCX-550 SWISS MADE BY COMAT AG Data at Tamb = 25°C and Vnom Type Decades /Select Decades /Display 3/0–999 3 CCX-550 Max. counting frequency 200 Hz 02 CE CK CI Supply, Power Consumption, Type AC 50/60 Hz DC U min – U max I max AC 220–240VA 190– 265V a 11mA AC 110–120VA 90–140Va 15 mA UC 24–48VU 19–60V a 110 mA U min – U max I max Type CCX-550/ATX CCX-550/ANP 19–60Vd 110 mA CCX-550/UFK Example of order: 1 preset counter CCX-550/ATX CCX-550/ATX AC220-240VA SWISS MADE BY COMAT AG CH-3076 WORB Wiring Diagramm Timing modes U 1 n 1 C R CE Q PNP Q is active after reaching the preselected number of pulses. Q and C can be reset with the reset button. U 1 n 1 C R CK Q Q is active during the preselected number of pulses and can only be reactivated after a reset. Q and C can be reset with the reset button. + COUNT NAMUR C R RESET U 1 n 1 1 n C R CI Q t ON OFF 8 Q is active for t75. ..125ms on the preselected pulse. The cycle starts again at the beginning. Q and C can be reset with the reset button. 7 6 5 4 OUTPUT Q U = Voltage C = Count R = Reset Q = Output relays A2 A1 9 10 11 1 2 3 A+ A General Technical data Output circuit Display 3-digit, 7-segment LEDs Load of triggering contact C/R 3mA/<15V Switching current max. Switching voltage max. Breaking capacity Mechanical life Contact material 6A 250V AC: 1500VA; DC: ... 250W 30 million operations Ag Ni 90/10 Technical data These values are valid for ohmic load or for inductive loading with spark arrest. Other contact material on request. ≥ 2,5ms ≥ 35ms 50ms Climate Ambient temperature range Storage temperature range 10–95% relat. humidity not condensing – 25… +60°C – 25… +80°C Transient voltage protection Specifications Protection/case material Weight incl. packing IEC 255.4. app. E, class III VDE 0435/0110 Gr.C, CE IP 40/Noryl SE1 to UL 94V-1 approx. 180g Dimensions Enclosure S3 72 Triggering time C Triggering time R Reset time 5 38 42 FZ-23 75 78 FS-23 4,5 9 Front mounting accessory FZ-23 (front panel aperture: 38,5x70 +– 00,5 mm, front panel thickness max. 3mm). Transparent front cover FS-23 (part of the scope of delivery.) 2 CC/6.02 E This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. Preset Counters CCX-350 SWISS MADE BY COMAT AG Data at Tamb = 25° C and Vnom Type Decades /Select Decades /Display 3/0–999 – CCX-350 Max. counting frequency 200 Hz 02 CE CK CI Supply, Power Consumption, Type AC 50/60 Hz DC U min – U max I max AC 220– 240VA 190– 265Va 11mA AC 110–120VA 90–140Va 15 mA UC 24– 48VU 19–60V a 110 mA U min – U max I max Type CCX-350/ATX CCX-350/ANP 19– 60V d 110 mA CCX-350/UFK Example of order: 1 preset counter CCX-350/ATX CCX-350/ATX AC220-240VA SWISS MADE BY COMAT AG CH-3076 WORB Wiring Diagram Timing modes U 1 n 1 C R CE Q PNP Q is active after reaching the preselected number of pulses. Q and C can be reset with the reset button. U 1 n 1 C R CK Q Q is active during the preselected number of pulses and can only be reactivated after a reset. Q and C can be reset with the reset button. + COUNT NAMUR C R RESET U 1 n 1 1 n C R CI Q t ON OFF 8 Q is active for t75...125ms on the preselected pulse. The cycle starts again at the beginning. Q and C can be reset with the reset button. 7 6 5 OUTPUT Q U = Voltage C = Count R = Reset Q = Output relays A2 Load of triggering contact C/R A1 9 10 11 1 2 3 A+ A Technical data 4 General Technical data Output circuit 3mA/<15V Switching current max. Switching voltage max. Breaking capacity Mechanical life Contact material 6A 250V AC: 1500VA; DC: ... 250W 30 million operations Ag Ni 90/10 These values are valid for ohmic load or for inductive loading with spark arrest. Other contact material on request. ≥ 2,5ms ≥ 35ms 50ms Climate Ambient temperature range Storage temperature range 10–95% relat. humidity not condensing – 25… +60°C – 25… +80°C Transient voltage protection Specifications Protection/case material Weight incl. packing IEC 255.4. app. E, class III VDE 0435/0110 Gr.C, CE IP 40/Noryl SE1 to UL 94V-1 approx. 180g Dimensions Enclosure S3 72 Triggering time C Triggering time R Reset time 5 38 42 FZ-23 75 78 FS-23 4,5 9 Front mounting accessory FZ-23 (front panel aperture: 38,5x70 +– 00,5 mm, front panel thickness max. 3mm). Transparent front cover FS-23 (part of the scope of delivery.) CC/6.02 E 3 Accessories EC-11 3 4 LH-1 L-16 12345 S+S, wieland 9 8 7 5 3 4 34 32 24 22 14 12 EC-11 16 30 4 8 75 A2-CONNECTOR FOR PLUG-IN MODULES A1 A2 11 10 6 1 15 3,2 29,5 C-A2 10 A 18 28 10 C-A2 for M3 SC-3 SD -1 A2 31 21 11 A1 10 11 6 1 2 24.2 M3 FOR M4 TEST 32 24 21 22 12 6 for M4 4 max 40 7 6 5 CS-11 10A 10A 400V 300V Listed 10A 400V 8 34 A2 31 11 A1 14 9 10 11 1 FOR PLUG-IN MODULES 2 3 CODING CA-11 LABEL SL-36 TS 35 5 68 7 8 Relay socket with screw, connections for panel or DIN mounting-snap fit 8 9 CS-11 Relay socket with screw, connections for panel or DIN mounting-snap fit LABELS Relay socket with screw, connections for panel or DIN mounting-snap fit SWISS MADE BY COMAT AG 62 C11A This issue replaces all previous issues. Availability, errors and specifications subject to change without notice. ø 5,3 S3 Case 38 4 2 3 22 38 38 4 4 20 20 RG-23 11 PGL Relay socket for chassis mounting 11 PGF Relay socket for fasten connectors (solder tags: 3,8x0,8 mm) (2xAMP 2,8x0,8 DIN 46247) Surface mounting case with built-in relay socket (protected connection terminals) 125 39 27 39 27 RG-23 1,5 15 38 HF-24 6,5 38 10 Retaining clip made of special spring steel suitable for all relay sockets 1,5 3,5 94 4 4,5 3,5 Faston 2,8x0,8 (2x) 4,5 4 38x 72 4,5 3 24 CS-11 67 3 6,5 11 10 50 FS-23 Transparent cover (always included with the relay) FZ-23 Front of panel mounting accessory comprising 2 front frame parts ➀ and 2 retaining clips ➁ 97 46 0,6 14 35 Gehäuse case, boîtier 0,5 0 +0,5 0 38 ,5 + S3 70 2 3 2 1 mi n. 4 CC/6.02 E 3 48 . 1.. Example of order: 1 relay socket type CS-11 3 1 2