NDLED4 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com NDLED4R Cut-Out Diameter: 5” IMPORTANT 4 NDLED4S Cut-Out: 5”x5” 3 2 REV DATE READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR DESCRIPTION FUTURE REFERENCE. 1 RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY AD PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. 4 3 4 2 3 REV DESCRIPTION 2 DATE 1 MOUNTING BARS D D D 4 3 2 C C C C Channel-27” Nailer Bar 13” adjustable to 24” (provided with fixture) C ChannelC-51” (order Cat #: C-Chan 27) Available upon request (order Cat #: C-Chan 51) Available upon request D 13.375" REF 27.000 [685,8] B SCALE 0.500 1.500 [38,1] .220 [5,59] .220 [5,59] 1. Nailer bars are provided for use with wood joist installations. Insert through Nailer Bar Slots in Butterfly Brackets and secure accordingly. C-Channels 4 are optionally available, consult factory. Consult local building codes for final support of fixture. .201 [5,11] (2) QUOTATION DRAWING 11-14-12 A .201 (2) L I G H T I N G [5,11] TITLE A MATERIAL: PROPERTY OF RAB LIGHTING, INCORPORATED ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING 2. Remove appropriate Knock out on Junction box. Press Clip to open the Junction Box. 3 DRAWN BY: DH 2 .250 [6,35] SCALE MA THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 15154-27 C-CHANNEL REV DATE: 3-9-12 1/2 2 REV PROPERTY OF RAB LIGHTING, INCORPORATED ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING SHEET: 3 1 QUOTATION DRAWING RAB Clip D L I G H T I N G 4. The fixture can be adjusted to different heights above the ceiling surface. For height adjustment, loosen the THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE Wing Nut and slide the ButterflyOF Bracket. If necessary PROPERTY RAB LIGHTING, INCORPORATED REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF remove the Wing NutANY and insert screw in different RAB LIGHTING, INC. ISin STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING 4 3 2 hole provided on the Butterfly Bracket. (Fig: 2) SCALE 0.500 SCALE 0.500 TITLE 170 LUDLOW AVE., NORTHVALE, NJ 07647 Nailer Bar Slot 13" NAILER BAR ASSEMBLY M &Male F Connector MATERIAL: PART No.: SEE NOTES DRAWN BY: DH 15153 Fig: 1 A DRAWING NAME: 15153 NAILER BAR ASSY DATE: REV DATE: 3-9-12 SCALE FULL SHEET: REV 1 Wing Nut SCALE 1.000 B Butterfly Bracket Fig: 2 SCALE 0.500 DR 2 Junction Box 3. Feed the supply wires throughNOTES: Knock out hole and 1. PART TO BE SUPPLIED BY TRIPAR INDUSTRIES PART NUMBER 1287 connect to the driver. See wiring section for details. 2. MATERIAL: GALVANIZED STEEL Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. RAB cannot troubleshoot Lutron systems and have provided only basic information. See www.lutron.com for complete instructions and functional compatibility of Lutron Drivers with Lutron or other Control systems/ dimmers. A DRAWING NAME: 15154-27 DATE: 4 TIT B 27" C-CHANNEL PART No.: 3 R L 170 LUDLOW AVE., NORTHVALE, NJ 07647 22 GA EC STL THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 4 5. Adjust both the Butterfly Brackets such that the frame of Rough-In Section is flush with the finished ceiling surface. Tighten the Wing nuts.C RAB Knock Out .250 [6,35] 27.000 [685,8] Rough-in Section (Bottom of the Rough-in Section to be flush with finished ceiling) B Butterfly Brackets ROUGH-IN MOUNTING C .500 [12,7] B E D NDLED4 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com TRIM MODULE MOUNTING 1. Pull Female Connector conduit through frame opening. Raise Trim Module towards opening and connect to Male Connector conduit as shown in Fig. 3 2. Press Torsion Springs inward and slide Trim Module C info frame opening. Release both springs into opening together. Trim Ring should be flush to ceiling. 3. For the Wallwash Model, orient the fixture such that the reflector is in correct orientation. Look for ‘Towards the Wall’ label on the fixture. Rough-in Section Male Connector Female Connector WIRING RISK OF FIRE. Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For Non-Dimming, Electronic Low Voltage (ELV) and Triac Dimming follow the wiring directions in Fig. 4. Trim Module 1. Connect the GROUND wire from fixture to supply ground. Trim Ring 2. Connect the black fixture lead to the (+) LINE supply lead. 3. Connect the white fixture lead to the (-) COMMON supply B lead. Fig: 3 Torsion Spring CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to SCALE 0.500 touch. Do not clean or maintain while fixture is energized. Fig: 4 Lutron L3D Hi-Lume series drivers work with Lutron 3-Wire Control (Fig. 5) or EcoSystem Digital Controls (Fig. 6). Note: See www.lutron.com for complete instructions and functional compatibility of Lutron drivers with Lutron or other control systems/ dimmers. 1. Do not open fixture to clean the LED. Do not touch the LED. 2. Do not touch reflector, lens, or trim cone. 3. Do not clean any fixture surface with wood base cleaning material such as paper towels or tissues. Only use micro fiber cleaning cloth. TROUBLESHOOTING 1. Check that the line voltage at the fixture is correct. Refer to wiring directions. Fig: 5 A 2. Is the fixture grounded properly? THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE PROPERTY 3. For questions on compatibility of dimmers purchased OFseparately RAB LIGHTING, INCORPORATED refer to www.rabweb.com ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY RABthe CONFIDENTIAL PATENT PENDING 4. If thePROHIBITED. LED is blinking fixture may be overheating. Remove the 3 Trim assembly and if the fixture is labeled ‘BLINKING LIGHT OF THIS THERMALLY PROTECTED LUMINAIRE MAY INDICATE OVERHEATING’ allow the fixture to cool down. Determine cause of overheating and remove. Fixtures with this label have a thermal protector that turns fixture off above a certain temperature. It will automatically restart when cool. 4 Fig: 6 Easy Installation & Product Help ©2014 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA NDLED4 IN-1214 Tech Help Line Call our experts 888 RAB-1000 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com TOLER .X .XX .XXX ANGLE NDLED4 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com DIMENSIONAL DRAWING NDLED4R 10.46 10.46” [265,7] 3.78 3.78” [96,1] Ø5.50 5.50” [139,8] 11.37” 11.37 [288,8] NDLED4S 10.46 10.46” [265,7] 3.79 3.79” [96,2] 5.50 5.50” [139,7] 5.50 5.50” [139,7] 11.37 11.37” [288,8] NDLED6 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com NDLED6R Cut-Out Diameter: 7” IMPORTANT 4 NDLED6S Cut-Out: 7”x7” 3 2 REV DATE READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR DESCRIPTION FUTURE REFERENCE. 1 RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY AD PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. 4 3 4 2 3 REV DESCRIPTION 2 DATE 1 MOUNTING BARS D D D 4 3 2 C C C C Channel-27” Nailer Bar 13” adjustable to 24” (provided with fixture) C ChannelC-51” (order Cat #: C-Chan 27) Available upon request (order Cat #: C-Chan 51) Available upon request D 13.375" REF 27.000 [685,8] B SCALE 0.500 1.500 [38,1] .220 [5,59] .220 [5,59] 1. Nailer bars are provided for use with wood joist installations. Insert through Nailer Bar Slots in Butterfly Brackets and secure accordingly. C-Channels 4 are optionally available, consult factory. Consult local building codes for final support of fixture. .201 [5,11] (2) QUOTATION DRAWING 11-14-12 A .201 (2) L I G H T I N G [5,11] TITLE A MATERIAL: PROPERTY OF RAB LIGHTING, INCORPORATED ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING 2. Remove appropriate Knock out on Junction box. Press Clip to open the Junction Box. 3 DRAWN BY: DH 2 .250 [6,35] SCALE MA THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 15154-27 C-CHANNEL REV DATE: 3-9-12 1/2 2 REV PROPERTY OF RAB LIGHTING, INCORPORATED ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING SHEET: 3 1 QUOTATION DRAWING RAB Clip D L I G H T I N G 4. The fixture can be adjusted to different heights above the ceiling surface. For height adjustment, loosen the THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE Wing Nut and slide the ButterflyOF Bracket. If necessary PROPERTY RAB LIGHTING, INCORPORATED REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF remove the Wing NutANY and insert screw in different RAB LIGHTING, INC. ISin STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING 4 3 2 hole provided on the Butterfly Bracket. (Fig: 2) SCALE 0.500 SCALE 0.500 TITLE 170 LUDLOW AVE., NORTHVALE, NJ 07647 Nailer Bar Slot 13" NAILER BAR ASSEMBLY M &Male F Connector MATERIAL: PART No.: SEE NOTES DRAWN BY: DH 15153 Fig: 1 A DRAWING NAME: 15153 NAILER BAR ASSY DATE: REV DATE: 3-9-12 SCALE FULL SHEET: REV 1 Wing Nut SCALE 1.000 B Butterfly Bracket Fig: 2 SCALE 0.500 DR 2 Junction Box 3. Feed the supply wires throughNOTES: Knock out hole and 1. PART TO BE SUPPLIED BY TRIPAR INDUSTRIES PART NUMBER 1287 connect to the driver. See wiring section for details. 2. MATERIAL: GALVANIZED STEEL Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. RAB cannot troubleshoot Lutron systems and have provided only basic information. See www.lutron.com for complete instructions and functional compatibility of Lutron Drivers with Lutron or other Control systems/ dimmers. A DRAWING NAME: 15154-27 DATE: 4 TIT B 27" C-CHANNEL PART No.: 3 R L 170 LUDLOW AVE., NORTHVALE, NJ 07647 22 GA EC STL THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 4 5. Adjust both the Butterfly Brackets such that the frame of Rough-In Section is flush with the finished ceiling surface. Tighten the Wing nuts.C RAB Knock Out .250 [6,35] 27.000 [685,8] Rough-in Section (Bottom of the Rough-in Section to be flush with finished ceiling) B Butterfly Brackets ROUGH-IN MOUNTING C .500 [12,7] B E D NDLED6 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com TRIM MODULE MOUNTING 1. Pull Female Connector conduit through frame opening. Raise Trim Module towards opening and connect to Male Connector conduit as shown in Fig. 3. 2. Press Torsion Springs inward and slide Trim Module C info frame opening. Release both springs into opening together. Trim Ring should be flush to ceiling. 3. For the Wallwash Model, orient the fixture such that the reflector is in correct orientation. Look for ‘Towards the Wall’ label on the fixture. Rough-in Section Male Connector Female Connector WIRING RISK OF FIRE. Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For Non-Dimming, Electronic Low Voltage (ELV) and Triac Dimming follow the wiring directions in Fig. 4. Trim Module 1. Connect the GROUND wire from fixture to supply ground. Trim Ring 2. Connect the black fixture lead to the (+) LINE supply lead. 3. Connect the white fixture lead to the (-) COMMON supply B lead. Fig: 3 Torsion Spring CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to SCALE touch. Do not clean or maintain while0.500 fixture is energized. Fig: 4 Lutron L3D Hi-Lume series drivers work with Lutron 3-Wire Control (Fig. 5) or EcoSystem Digital Controls (Fig. 6). Note: See www.lutron.com for complete instructions and functional compatibility of Lutron drivers with Lutron or other control systems/ dimmers. 1. Do not open fixture to clean the LED. Do not touch the LED. 2. Do not touch reflector, lens, or trim cone. 3. Do not clean any fixture surface with wood base cleaning material such as paper towels or tissues. Only use micro fiber cleaning cloth. TROUBLESHOOTING 1. Check that the line voltage at the fixture is correct. Refer to wiring directions. Fig: 5 A 2. Is the fixture grounded properly? THIS DRAWING AND THE IT DISCLOSES IS THE EXCLUSIVE 3.INFORMATION For questions on compatibility of dimmers purchased PROPERTY refer to www.rabweb.com OFseparately RAB LIGHTING, INCORPORATED ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF 4. If thePROHIBITED. LED is blinking fixture may be overheating. RAB LIGHTING, INC. IS STRICTLY RABthe CONFIDENTIAL PATENT PENDING Remove the Trim assembly and if the fixture is labeled 3 ‘BLINKING LIGHT OF THIS THERMALLY PROTECTED LUMINAIRE MAY INDICATE OVERHEATING’ allow the fixture to cool down. Determine cause of overheating and remove. Fixtures with this label have a thermal protector that turns fixture off above a certain temperature. It will automatically restart when cool. 4 Fig: 6 Easy Installation & Product Help ©2014 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA NDLED6 IN-1114 Tech Help Line Call our experts 888 RAB-1000 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com TOLER .X .XX .XXX ANGLE NDLED6 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com DIMENSIONAL DRAWING NDLED6R 12.42 12.42” [315,4] 4.82 4.82” [122,5] Ø7.52 7.52” [190,9] 13.46 13.46” [341,9] NDLED6S 12.63 12.63” [320,8] 4.44 4.44” [112,7] 13.37 7.52” [339,6] 13.37 7.52” [339,6] 13.37 13.37” [339,6] NDIC4 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com NDIC4R Cut-Out Diameter: 5” IMPORTANT 4 NDIC4S Cut-Out: 5”x5” 3 2 REV DATE READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR DESCRIPTION FUTURE REFERENCE. 1 RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY AD PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. 4 3 4 2 3 REV DESCRIPTION 2 DATE 1 MOUNTING BARS D D D C C C C Channel-27” Nailer Bar 13” adjustable to 24” (provided with fixture) C ChannelC-51” (order Cat #: C-Chan 27) Available upon request 13.375" REF 27.000 [685,8] B (order Cat #: C-Chan 51) Available upon request .500 [12,7] B 27.000 [685,8] B Butterfly Brackets ROUGH-IN MOUNTING SCALE 0.500 1.500 [38,1] .220 [5,59] .220 [5,59] 1. Nailer bars are provided for use with wood joist installations. Insert through Nailer Bar Slots in Butterfly Brackets and secure accordingly. C-Channels are optionally available, consult factory. Consult local building codes for final support of fixture. .201 [5,11] (2) QUOTATION DRAWING 11-14-12 A PART No.: DATE: DRAWN BY: DH 2 Junction Box Cover SCALE 4 A MA THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 15154-27 C-CHANNEL REV DATE: 3-9-12 1/2 REV PROPERTY OF RAB LIGHTING, INCORPORATED ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING SHEET: 3 1 RAB SCALE 0.500 SCALE 0.500 Rough-in Section 170 LUDLOW AVE., NORTHVALE, NJ 07647 (Bottom of the Male Connector 13" NAILER BAR ASSEMBLY M & FRough-in Section toAbe flush with Fig: 1 MATERIAL: PART No.: DRAWING NAME: finished ceiling) L I G H T I N G Nailer BarTITLE Slot 4. The fixture can be adjusted to different heights above THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE the ceiling surface. ForPROPERTY height adjustment, loosen theINCORPORATED OF RAB LIGHTING, ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF Wing Nut and slide the Bracket. If necessary RAB Butterfly LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING 4 3 2 remove the Wing Nut and insert in screw in different hole provided on the Butterfly Bracket. (Fig: 2) SEE NOTES DRAWN BY: DH 15153 15153 NAILER BAR ASSY DATE: REV DATE: 3-9-12 SCALE FULL SHEET: REV 1 10.462 [265,74 6.232 [158,28 ] ] SCALE 1.000 11.475 [291,47 ] DR 2 QUOTATION DRAWING Clip 3. Feed the supply wires throughNOTES: Knock out hole and 1. PART TO BE SUPPLIED BY TRIPAR INDUSTRIES PART NUMBER 1287 connect to the driver. Re-install Junction Box Cover. See 2. MATERIAL: GALVANIZED STEEL wiring section for details. TIT B DRAWING NAME: 15154-27 PROPERTY OF RAB LIGHTING, INCORPORATED 3 .250 [6,35] 27" C-CHANNEL 22 GA EC STL ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING R L 170 LUDLOW AVE., NORTHVALE, NJ 07647 MATERIAL: THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 2. Remove appropriate Knock out on Junction box. Press Clip to remove the Junction Box Cover. RAB NDIC4 fixtures are IC rated allowing fixtures to be completely covered with insulation and also comply with minimum Air Leakage requirements per the Washington State Energy Code and Model Energy Code. .201 (2) L I G H T I N G [5,11] TITLE A 4 5. Adjust both the Butterfly Brackets such that the frame of Rough-In Section is flush with the finished ceiling surface. Tighten the Wing nuts. RAB Knock Out .250 [6,35] Butterfly Bracket Fig: 2 Wing Nut NDIC4 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com TRIM MODULE MOUNTING 1. Pull Male Connector conduit through frame opening. Raise Trim Module towards opening and connect to Female Connector conduit as shown in Fig. 3. 2. Press Torsion Springs inward and slide Trim Module info frame opening. Release both springs into opening together. Trim Ring should be flush to ceiling. 3. For the Wallwash Model, orient the fixture such that the reflector is in correct orientation. Look for ‘Towards the Wall’ label on the fixture. WIRING RISK OF FIRE. Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For Non-Dimming, Electronic Low Voltage (ELV) and Triac Dimming follow the wiring directions in Fig. 4. Rough-in Section Ceiling Male Connector Female Connector Trim Module Torsion Spring 1. Connect the GROUND wire from fixture to supply ground. 2. Connect the black fixture lead to the (+) LINE supply lead. 3. Connect the white fixture lead to the (-) COMMON supply lead. Trim Ring 10.462 [265,74 Fig: 3 ] CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. Fig: 4 Lutron L3D Hi-Lume series drivers work with Lutron 3-Wire Control (Fig. 5) or EcoSystem Digital Controls (Fig. 6). Note: See www.lutron.com for complete instructions and functional compatibility of Lutron drivers with Lutron or other control systems/ 11.475 dimmers. [291,47 ] 1. Do not open fixture to clean the LED. Do not touch the LED. 2. Do not touch reflector, lens, or trim cone. 3. Do not clean any fixture surface with wood base cleaning material such as paper towels or tissues. Only use micro fiber cleaning cloth. TROUBLESHOOTING 1. Check that the line voltage at the fixture is correct. Refer to wiring directions. Fig: 5 2. Is the fixture grounded properly? 3. For questions on compatibility of dimmers purchased separately refer to www.rabweb.com Fig: 6 Easy Installation & Product Help ©2014 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA NDIC4 IN-1214 Tech Help Line Call our experts 888 RAB-1000 Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. RAB cannot troubleshoot Lutron systems and have provided only basic information. See www.lutron.com for complete instructions and functional compatibility of Lutron Drivers with Lutron or other Control systems/ dimmers. rabweb.com Visit our website for product info 10.462 [26 email 5,74] Answered promptly sales@rabweb.com 6.232 [158,28 NDIC4 INSTALLATION INSTRUCTIONS 11.475 [291,47] Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com DIMENSIONAL DRAWING 4” Round 11.48” 10.462 [265,74] 10.46” 10.462 [265,74] 10.46” 5.5” 5.500 [139,7] Cut-Out Diameter: 5” 11.826 [300,38] 11.83” 11.826 [300,38] 4” Square 11.83” 10.462 [265,74] 10.46” 11.826 [300,38] 6.224 [158,09] 5.5” 422.6 ]90,851[ 005.5 ]7,931[ 264.01 ]47,562[ 10.46” 5.500 [139,7] 10.462 [265,74] Cut-Out Dimension: 5”x5” 6.23” 11.83” 6.232 [158,28] 6.23” 628.11 ]83,003[ NDIC6 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com NDIC6R Cut-Out Diameter: 7” IMPORTANT 4 NDIC6S Cut-Out: 7”x7” 3 2 REV DATE READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR DESCRIPTION FUTURE REFERENCE. 1 RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY AD PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. 4 3 4 2 3 REV DESCRIPTION 2 DATE 1 MOUNTING BARS D D D C C C C Channel-27” Nailer Bar 13” adjustable to 24” (provided with fixture) C ChannelC-51” (order Cat #: C-Chan 27) Available upon request 13.375" REF 27.000 [685,8] B (order Cat #: C-Chan 51) Available upon request .500 [12,7] B Butterfly Brackets ROUGH-IN MOUNTING 1. Nailer bars are provided for use with wood joist installations. Insert through Nailer Bar Slots in Butterfly Brackets and secure accordingly. C-Channels are optionally available, consult factory. Consult local building codes for final support of fixture. (2) QUOTATION DRAWING 11-14-12 RAB .250 [6,35] A SCALE 0.500 1.500 [38,1] .220 [5,59] .220 [5,59] .201 [5,11] 27.000 [685,8] B MATERIAL: 2. Remove appropriate Knock out on Junction box. Press Clip to remove the Junction Box Cover. 3. Feed the supply wires through Knock out hole and connect to the driver. Re-install Junction Box Cover. See wiring section for details. 3 Nailer Bar Slot NOTES: 1. PART TO BE SUPPLIED BY TRIPAR INDUSTRIES PART NUMBER 1287 2. MATERIAL: GALVANIZED STEEL 4 SCALE A Junction Box Cover REV DATE: 3-9-12 1/2 REV PROPERTY OF RAB LIGHTING, INCORPORATED ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING SHEET: 3 1 2 Clip RAB 12.418 [315,43] SCALE 0.500 SCALE 0.500 L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647 TITLE Rough-in Section 13" NAILER BAR ASSEMBLY(Bottom M & Fof the Male Connector Rough-in Section MATERIAL: Fig: 1 DRAWN BY: DH A PART No.: SEE NOTES 15153 DRAWING NAME: to be flush with ceiling) finished 15153 NAILER BAR ASSY DATE: REV DATE: 3-9-12 SCALE FULL SHEET: REV 1 SCALE 1.000 Butterfly Bracket MA THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 15154-27 C-CHANNEL QUOTATION DRAWING 4. The fixture can be adjusted to different heights above THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE the ceiling surface. ForPROPERTY height adjustment, loosen theINCORPORATED OF RAB LIGHTING, ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF Wing Nut and slide the Bracket. If necessary RAB Butterfly LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING 4 3 2 remove the Wing Nut and insert in screw in different hole provided on the Butterfly Bracket. (Fig: 2) RAB NDIC6 fixtures are IC rated allowing fixtures to be completely covered with insulation and also comply with 13.91State minimum Air Leakage requirements per the Washington 6 [353,47] Energy Code and Model Energy Code. DRAWN BY: DH 2 L TIT B DRAWING NAME: 15154-27 DATE: PROPERTY OF RAB LIGHTING, INCORPORATED ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING .250 [6,35] 27" C-CHANNEL PART No.: R Knock Out 170 LUDLOW AVE., NORTHVALE, NJ 07647 22 GA EC STL THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 4 5. Adjust both the Butterfly Brackets such that the frame of Rough-In Section is flush with the finished ceiling surface. Tighten the Wing nuts. .201 (2) L I G H T I N G [5,11] TITLE A Fig: 2 Wing Nut 13.916 [353,4 7.516 DR NDIC6 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com TRIM MODULE MOUNTING 1. Pull Male Connector conduit through frame opening. Raise Trim Module towards opening and connect to Female Connector conduit as shown in Fig. 3. 2. Press Torsion Springs inward and slide Trim Module info frame opening. Release both springs into opening together. Trim Ring should be flush to ceiling. 3. For the Wallwash Model, orient the fixture such that the reflector is in correct orientation. Look for ‘Towards the Wall’ label on the fixture. Rough-in Section Ceiling WIRING RISK OF FIRE. Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For Non-Dimming, Electronic Low Voltage (ELV) and Triac Dimming follow the wiring directions in Fig. 4. 1. Connect the GROUND wire from fixture to supply ground. 2. Connect the black fixture lead to the (+) LINE supply lead. 3. Connect the white fixture lead to the (-) COMMON supply lead. Male Connector Female Connector Trim Module Torsion Spring Trim Ring Fig: 3 CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. Fig: 4 Lutron L3D Hi-Lume series drivers work with Lutron 3-Wire Control (Fig. 5) or EcoSystem Digital Controls (Fig. 6). Note: See www.lutron.com for complete instructions and functional 13.9 16 compatibility of Lutron drivers with Lutron or other control systems/ [353,4 7] dimmers. 1. Do not open fixture to clean the LED. Do not touch the LED. 2. Do not touch reflector, lens, or trim cone. 3. Do not clean any fixture surface with wood base cleaning material such as paper towels or tissues. Only use micro fiber cleaning cloth. TROUBLESHOOTING 13.916 [353,47] 1. Check that the line voltage at the fixture is correct. Refer to wiring directions. Fig: 5 2. Is the fixture grounded properly? 3. For questions on compatibility of dimmers purchased separately refer to www.rabweb.com Fig: 6 Easy Installation & Product Help ©2014 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA NDIC6 IN-1214 Tech Help Line Call our experts 888 RAB-1000 Note: These instructions do not cover all details or variations in 12.418 equipment nor do they provide for every possible situation during [315,43] installation, operation or maintenance. RAB cannot troubleshoot Lutron systems and have provided only basic information. See www.lutron.com for complete instructions and functional compatibility of Lutron Drivers with Lutron or other Control systems/ dimmers. rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com 7 [ NDIC6 INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com NDIC6R 13.916 [353,47] DIMENSIONAL DRAWING 13.92” 12.418 [315,43] 12.42” 242.6 ]55,851[ 13.916 [353,47] 6.24” 12.418 [315,43] 7.516 [190,91] Cut-Out Diameter: 7” 814.21 ]34,513[ 615.7 ]19,091[ 7.52” 12.42” 6.242 [158,55] 619.31 ]74,353[ 13.92” 13.826 [351,18] 13.83” NDIC6S 12.631 [320,82] 12..63” 814.21 ]34,513[ 13.826 [351,18] 032.6 ]32,851[ 032.6 ]32,851[ 619.31 7.515 ]74,353[ [190,88] 12.631 [320,82] 6.23” 628.31 ]81,153[ 136.21 ]28,023[ 13.83” 12.63” 515.7 ]88,091[ 7.52” 628.31 ]81,153[ 136.21 ]28,023[ 515.7 ]88,091[ 6.230 [158,23] Cut-Out Dimension: 7”x7” NDIC4 EMERGENCY BATTERY BACKUP INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com NDIC4R/E2 Cut-Out Diameter: 5” NDIC4S/E2 Cut-Out: 5”x5” IMPORTANT SUITABLE FOR INSTALLATION IN NON-ACCESSIBLE CEILINGS ONLY. READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. THIS IS AN EMERGENCY BATTERY BACKUP FIXTURE THAT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OFF PROPERLY. SAFETY INSTRUCTIONS 4 3 2 WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. REV DESCRIPTION DATE WARNING: Suitable for wet locations where the ambient temperature is 0° C minimum, +40° C maximum. 1 WARNING: Suitable for installation in Insulated Ceilings only. D 4 3 4 2 3 REV DESCRIPTION 2 DATE 1 MOUNTING BARS D D D C C C C Channel-27” Nailer Bar 13” adjustable to 24” (provided with fixture) C ChannelC-51” (order Cat #: C-Chan 27) Available upon request 13.375" REF 27.000 [685,8] B OPERATION (order Cat #: C-Chan 51) Available upon request .500 [12,7] B 27.000 [685,8] B SCALE 0.500 1.500 [38,1] .220 [5,59] .220 [5,59] QUOTATION DRAWING 11-14-12 1. When AC power is applied, the charging indicator light is illuminated, indicating that the battery is being charged. RAB B 2. When power fails, the emergency ballast automatically switches to emergency power (internal battery), operating at reduced 27" C-CHANNEL illumination. The emergency ballast supplies 7W of power (measured at nominal battery voltage) at a maximum rated current PROPERTY OF RAB LIGHTING, INCORPORATED PROPERTY OF RAB LIGHTING, INCORPORATED of 270mA with a maximum voltage of 50VDC in emergency mode for a minimum of 90 minutes. 3. When AC power is restored, the emergency ballast automatically returns to charging mode. .201 [5,11] (2) .250 [6,35] A .201 (2) L I G H T I N G [5,11] TITLE A 170 LUDLOW AVE., NORTHVALE, NJ 07647 .250 [6,35] A MATERIAL: 15154-27 DATE: ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING 4 PART No.: 22 GA EC STL THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 3 DRAWN BY: DH 2 4 SCALE DRAWING NAME: REV ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING SHEET: 1 3 2 QUOTATION DRAWING RAB RAB NDIC4 fixtures are IC rated allowing NOTES: fixtures to be completely covered with insulation and also comply with minimum Air Leakage 1. PART TO BE SUPPLIED BY TRIPAR INDUSTRIES L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647 requirements per the Washington State Energy1287 Code and Model Energy Code. PART NUMBER TITLE SCALE 0.500 2. MATERIAL: GALVANIZED STEEL 13" NAILER BAR ASSEMBLY M & F MATERIAL: THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE PART No.: SEE NOTES 15153 DATE: MA THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 15154-27 C-CHANNEL REV DATE: 3-9-12 1/2 R L TIT DRAWING NAME: 15153 NAILER BAR ASSY REV DATE: REV A SCALE 0.500 DR NDIC4 EMERGENCY BATTERY BACKUP INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com ROUGH-IN MOUNTING Knock Out Junction Box Cover Butterfly Brackets 1. Nailer bars are provided for use with wood joist installations. Insert through Nailer Bar Slots in Butterfly Brackets and secure accordingly. C-Channels are optionally available, consult factory. Consult local building codes for final support of fixture. Fig. 1 Clip 2. Remove appropriate Knock out on Junction box. Press Clip to remove the Junction Box Cover. 3. Feed the supply wires through Knock out hole and connect to the driver. Re-install Junction Box Cover. See wiring section for details. Rough-in Section (Bottom of the Rough-in Section to be flush with finished ceiling) Nailer Bar Slot 4. The fixture can be adjusted to different heights above the ceiling surface. For height adjustment, loosen the Wing Nut and slide the Butterfly Bracket. If necessary remove the Wing Nut and insert in screw in different hole provided on the Butterfly Bracket. (Fig: 2) Male Connector Fig. 2 5. Adjust both the Butterfly Brackets such that the frame of Rough-In Section is flush with the finished ceiling surface. Tighten the Wing nuts. TRIM MODULE MOUNTING 1. Pull Male Connector conduit through frame opening. Raise Trim Module towards opening and connect to Female Connector conduit as shown in Fig. 3. Wing Nut Butterfly Bracket 2. Press Torsion Springs inward and slide Trim Module info frame opening. Release both springs into opening together. Trim Ring should be flush to ceiling. 3. For the Wallwash Model, orient the fixture such that the reflector is in correct orientation. Look for ‘Towards the Wall’ label on the fixture. Fig. 3 Rough-in Section Ceiling Male Connector Trim Module Female Connector Torsion Spring Trim Ring NDIC4 EMERGENCY BATTERY BACKUP INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com WIRING TROUBLESHOOTING CAUTION: THIS IS AN EMERGENCY BATTERY BACKUP FIXTURE. Voltage could be present in Battery. To prevent high voltage from being present on output leads, inverter connector must be open. Do not join inverter connector until installation is complete and AC power is supplied to the emergency ballast. 1. Check that the line voltage at the fixture is correct. Refer to wiring directions. NOTE: Make sure that the necessary branch circuit wiring is available. An unswitched AC source of power is required. The emergency ballast must be fed from the same branch circuit as the AC ballast. 4. If the LED is blinking the fixture may be overheating. Remove the Trim assembly and if the fixture is labeled ‘BLINKING LIGHT OF THIS THERMALLY PROTECTED LUMINAIRE MAY INDICATE OVERHEATING’ allow the fixture to cool down. Determine cause of overheating and remove. Fixtures with this label have a thermal protector that turns fixture off above a certain temperature. It will automatically restart when cool. Do not use any supply voltage other than those specified below. NDIC4R/E2 or NDIC4S/E2 120V-277V, 50/60Hz 1. Connect the UNSWITCHED black fixture lead to the HOT supply lead. 2. Connect red and black lead together, if not using a switching method. 3. If switching, connect SWITCHED red lead to a switch. 4. Connect the COMMON fixture lead to the COMMON supply lead. 5.For Lutron system, follow manufacturer’s instructions. 5. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output. 6. All unused leads must be capped and insulated. 7. After installation is complete, supply AC power to the emergency ballast and join the inverter connector. 9. At this point, power should be connected to both the AC ballast and the emergency ballast, and the Charging Indicator Light should illuminate indicating the battery is charging. 10. A short-term discharge test may be conducted after the emergency ballast has been charging for one hour. Charge for 24 hours before conducting a long-term discharge test. Refer to OPERATION. 2. Is the fixture grounded properly? 3. For questions on compatibility of dimmers purchased separately refer to www.rabweb.com CLEANING CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. 1. Do not open fixture to clean the LEDs. Do not touch the LEDs. 2. Do not touch reflector, lens, or trim cone. 3. Do not clean any fixture surface with wood base cleaning material such as paper towels or tissues. Only use micro fiber cleaning cloth. MAINTENANCE Although no routine maintenance is required to keep the emergency ballast functional, it should be checked periodically to ensure that it is working. The following schedule is recommended: 1. Visually inspect the charging indicator light monthly. It should be illuminated. 2. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds. 3. Conduct a 90-minute discharge test once a year. Fixture would operate at reduced illumination for a minimum of 90 minutes. To reduce the risk of electric shock, disconnect both normal and emergency power supplies and converter connector of the emergency ballast before servicing. Do not attempt to service the emergency ballast. The use of accessory equipment may cause an unsafe condition. Do not use this product for other than intended use. Refer any servicing indicated by these checks to a Qualified Service Personnel. Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. RAB cannot troubleshoot Lutron systems and have provided only basic information. See www.lutron.com for complete instructions and functional compatibility of Lutron Drivers with Lutron or other Control systems/dimmers. Easy Installation & Product Help ©2014 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA NDIC4 EM IN 1115 Tech Help Line Call our experts 888 RAB-1000 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com NDIC4 EMERGENCY BATTERY BACKUP INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com DIMENSIONAL DRAWING 13.39” 4” Round 7.07” 13.06” 6.12” Ø 5.50” 13.39” 7.07” 4” Square 12.94” 6.12” Ø 5.50” RED WHITE Northvale, New Jersey 07647 USA ©2012 RAB LIGHTING Inc. NDIC4 EM IN 1115 BROWN BROWN VIOLET VIOLET BLACK YELLOW BLUE BLACK RED YELLOW Tech Help Line Call our experts 888 RAB-1000 WHITE WHITE RED + BLUE OR BLACK - BLACK RED 8" Flex Conduit Whip LED TRIM MODULE - BLACK email Answered promptly sales@rabweb.com SWITCH PLATE WITH INTEGRAL TEST SWITCH (INCLUDED) SWITCH BOX (BY OTHERS) YELLOW - BLACK STRIPE ELECTRONIC BLOCK PROTECTOR JUNCTION BOX BLUE rabweb.com Visit our website for product info Easy Installation & Product Help CUSTOMER SHOULD CONNECT ONLY AFTER FINISHING WIRING TO AC POWER. BATTERY COULD HAVE CHARGE & SHOCK. INVERTER CONNECTOR: CONNECT ONLY AFTER AC SUPPLY POWER IS CONNECTED RAB LABEL - ADD 2' Flex Conduit Whip ORANGE - BLACK STRIPE WHITE - RED STRIPE EMERGENCY LED DRIVER BSL17C-C2 BODINE YELLOW - BLACK STRIPE WHITE WHITE - BLACK STRIPE LED DRIVER 120V - 277V Emergency Ballast and AC Ballast must be fed from the same circuit WIRING DIAGRAM for EMERGENCY OPERATION at 120V - 277V + RAB LABEL ADD BLACK RAB LABEL ADD IF NOT SWITCHED, THEN CAP TOGETHER JUNCTION BOX CONNECT TO MAIN POWER UNSWITCHED SWITCHED COMMON GROUND WHITE Northvale, New Jersey 07647 USA BROWN BROWN VIOLET VIOLET BLACK YELLOW BLUE BLACK RED Tech Help Line Call our experts 888 RAB-1000 YELLOW TP WHITE BLACK WHITE RED + BLUE OR BLACK - BLACK RED 8" Flex Conduit Whip LED TRIM MODULE - BLACK email Answered promptly sales@rabweb.com SWITCH PLATE WITH INTEGRAL TEST SWITCH (INCLUDED) SWITCH BOX (BY OTHERS) YELLOW - BLACK STRIPE ELECTRONIC BLOCK PROTECTOR JUNCTION BOX BLUE rabweb.com Visit our website for product info Easy Installation & Product Help CUSTOMER SHOULD CONNECT ONLY AFTER FINISHING WIRING TO AC POWER. BATTERY COULD HAVE CHARGE & SHOCK. INVERTER CONNECTOR: CONNECT ONLY AFTER AC SUPPLY POWER IS CONNECTED ©2012 RAB LIGHTING Inc. NDIC4 EM IN 1115 RED RAB LABEL - ADD 2' Flex Conduit Whip ORANGE - BLACK STRIPE WHITE - RED STRIPE EMERGENCY LED DRIVER BSL17C-C2 BODINE YELLOW - BLACK STRIPE WHITE WHITE - BLACK STRIPE BLACK LED DRIVER 120V - 277V Emergency Ballast and AC Ballast must be fed from the same circuit TP CONNECT TO MAIN POWER UNSWITCHED SWITCHED COMMON GROUND Thermal Protector RAB LABEL ADD BLACK RAB LABEL ADD IF NOT SWITCHED, THEN CAP TOGETHER JUNCTION BOX WIRING DIAGRAM for EMERGENCY OPERATION at 120V - 277V with Thermal Protector + NDIC6 EMERGENCY BATTERY BACKUP INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com NDIC6R/E2 Cut-Out Diameter: 7” NDIC6S/E2 Cut-Out: 7” x7” IMPORTANT SUITABLE FOR INSTALLATION IN NON-ACCESSIBLE CEILINGS ONLY. READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. THIS IS AN EMERGENCY BATTERY BACKUP FIXTURE THAT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OFF PROPERLY. SAFETY INSTRUCTIONS 4 3 2 WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. REV DESCRIPTION DATE WARNING: Suitable for wet locations where the ambient temperature is 0° C minimum, +40° C maximum. 1 WARNING: Suitable for installation in Insulated Ceilings only. D 4 3 4 2 3 REV DESCRIPTION 2 DATE 1 MOUNTING BARS D D D C C C C Channel-27” Nailer Bar 13” adjustable to 24” (provided with fixture) C ChannelC-51” (order Cat #: C-Chan 27) Available upon request 13.375" REF 27.000 [685,8] B OPERATION (order Cat #: C-Chan 51) Available upon request .500 [12,7] B 27.000 [685,8] B SCALE 0.500 1.500 [38,1] .220 [5,59] .220 [5,59] QUOTATION DRAWING 11-14-12 1. When AC power is applied, the charging indicator light is illuminated, indicating that the battery is being charged. RAB B 2. When power fails, the emergency ballast automatically switches to emergency power (internal battery), operating at reduced 27" C-CHANNEL illumination. The emergency ballast supplies 7W of power (measured at nominal battery voltage) at a maximum rated current PROPERTY OF RAB LIGHTING, INCORPORATED PROPERTY OF RAB LIGHTING, INCORPORATED of 270mA with a maximum voltage of 50VDC in emergency mode for a minimum of 90 minutes. 3. When AC power is restored, the emergency ballast automatically returns to charging mode. .201 [5,11] (2) .250 [6,35] A .201 (2) L I G H T I N G [5,11] TITLE A 170 LUDLOW AVE., NORTHVALE, NJ 07647 .250 [6,35] A MATERIAL: 15154-27 DATE: ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING 4 PART No.: 22 GA EC STL THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 3 DRAWN BY: DH 2 4 SCALE DRAWING NAME: REV ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING SHEET: 1 3 2 QUOTATION DRAWING RAB RAB NDIC6 fixtures are IC rated allowing NOTES: fixtures to be completely covered with insulation and also comply with minimum Air Leakage 1. PART TO BE SUPPLIED BY TRIPAR INDUSTRIES L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647 requirements per the Washington State Energy1287 Code and Model Energy Code. PART NUMBER TITLE SCALE 0.500 2. MATERIAL: GALVANIZED STEEL 13" NAILER BAR ASSEMBLY M & F MATERIAL: THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE PART No.: SEE NOTES 15153 DATE: MA THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE 15154-27 C-CHANNEL REV DATE: 3-9-12 1/2 R L TIT DRAWING NAME: 15153 NAILER BAR ASSY REV DATE: REV A SCALE 0.500 DR NDIC6 EMERGENCY BATTERY BACKUP INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com ROUGH-IN MOUNTING 1. Nailer bars are provided for use with wood joist installations. Insert through Nailer Bar Slots in Butterfly Brackets and secure accordingly. C-Channels are optionally available, consult factory. Consult local building codes for final support of fixture. Fig. 1 Butterfly Brackets Knock Out Junction Box Cover Clip 2. Remove appropriate Knock out on Junction box. Press Clip to remove the Junction Box Cover. 3. Feed the supply wires through Knock out hole and connect to the driver. Re-install Junction Box Cover. See wiring section for details. Nailer Bar Slot Male Connector 4. The fixture can be adjusted to different heights above the ceiling surface. For height adjustment, loosen the Wing Nut and slide the Butterfly Bracket. If necessary remove the Wing Nut and insert in screw in different hole provided on the Butterfly Bracket. (Fig: 2) Rough-in Section (Bottom of the Rough-in Section to be flush with finished ceiling) Fig. 2 5. Adjust both the Butterfly Brackets such that the frame of Rough-In Section is flush with the finished ceiling surface. Tighten the Wing nuts. TRIM MODULE MOUNTING 1. Pull Male Connector conduit through frame opening. Raise Trim Module towards opening and connect to Female Connector conduit as shown in Fig. 3. Wing Nut Butterfly Bracket 2. Press Torsion Springs inward and slide Trim Module info frame opening. Release both springs into opening together. Trim Ring should be flush to ceiling. 3. For the Wallwash Model, orient the fixture such that the reflector is in correct orientation. Look for ‘Towards the Wall’ label on the fixture. Fig. 3 Rough-in Section Ceiling Male Connector Female Connector Torsion Spring Trim Module Trim Ring NDIC6 EMERGENCY BATTERY BACKUP INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com WIRING TROUBLESHOOTING CAUTION: THIS IS AN EMERGENCY BATTERY BACKUP FIXTURE. Voltage could be present in Battery. To prevent high voltage from being present on output leads, inverter connector must be open. Do not join inverter connector until installation is complete and AC power is supplied to the emergency ballast. 1. Check that the line voltage at the fixture is correct. Refer to wiring directions. NOTE: Make sure that the necessary branch circuit wiring is available. An unswitched AC source of power is required. The emergency ballast must be fed from the same branch circuit as the AC ballast. 4. If the LED is blinking the fixture may be overheating. Remove the Trim assembly and if the fixture is labeled ‘BLINKING LIGHT OF THIS THERMALLY PROTECTED LUMINAIRE MAY INDICATE OVERHEATING’ allow the fixture to cool down. Determine cause of overheating and remove. Fixtures with this label have a thermal protector that turns fixture off above a certain temperature. It will automatically restart when cool. Do not use any supply voltage other than those specified below. NDIC6R/E2 or NDIC6S/E2 120V-277V, 50/60Hz 1. Connect the UNSWITCHED black fixture lead to the HOT supply lead. 2. Connect red and black lead together, if not using a switching method. 3. If switching, connect SWITCHED red lead to a switch. 4. Connect the COMMON fixture lead to the COMMON supply lead. 5.For Lutron system, follow manufacturer’s instructions. 5. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output. 6. All unused leads must be capped and insulated. 7. After installation is complete, supply AC power to the emergency ballast and join the inverter connector. 9. At this point, power should be connected to both the AC ballast and the emergency ballast, and the Charging Indicator Light should illuminate indicating the battery is charging. 10. A short-term discharge test may be conducted after the emergency ballast has been charging for one hour. Charge for 24 hours before conducting a long-term discharge test. Refer to OPERATION. 2. Is the fixture grounded properly? 3. For questions on compatibility of dimmers purchased separately refer to www.rabweb.com CLEANING CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. 1. Do not open fixture to clean the LEDs. Do not touch the LEDs. 2. Do not touch reflector, lens, or trim cone. 3. Do not clean any fixture surface with wood base cleaning material such as paper towels or tissues. Only use micro fiber cleaning cloth. MAINTENANCE Although no routine maintenance is required to keep the emergency ballast functional, it should be checked periodically to ensure that it is working. The following schedule is recommended: 1. Visually inspect the charging indicator light monthly. It should be illuminated. 2. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds. 3. Conduct a 90-minute discharge test once a year. Fixture would operate at reduced illumination for a minimum of 90 minutes. To reduce the risk of electric shock, disconnect both normal and emergency power supplies and converter connector of the emergency ballast before servicing. Do not attempt to service the emergency ballast. The use of accessory equipment may cause an unsafe condition. Do not use this product for other than intended use. Refer any servicing indicated by these checks to a Qualified Service Personnel. Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. RAB cannot troubleshoot Lutron systems and have provided only basic information. See www.lutron.com for complete instructions and functional compatibility of Lutron Drivers with Lutron or other Control systems/dimmers. Easy Installation & Product Help ©2014 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA NDIC4 EM IN 1115 Tech Help Line Call our experts 888 RAB-1000 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com NDIC6 EMERGENCY BATTERY BACKUP INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com DIMENSIONAL DRAWING 6” Round 15.452 [392,48] 8.110 [205,99] 13 [330] 6.125 [155,56] 6” Square 15.362 [390,19] 8.065 [204,85] 13 [330] 6.125 [155,56] RED WHITE Northvale, New Jersey 07647 USA ©2012 RAB LIGHTING Inc. NDIC46 EM IN 1215 BROWN BROWN VIOLET VIOLET BLACK YELLOW BLUE BLACK RED YELLOW Tech Help Line Call our experts 888 RAB-1000 WHITE WHITE RED + BLUE OR BLACK - BLACK RED 8" Flex Conduit Whip LED TRIM MODULE - BLACK email Answered promptly sales@rabweb.com SWITCH PLATE WITH INTEGRAL TEST SWITCH (INCLUDED) SWITCH BOX (BY OTHERS) YELLOW - BLACK STRIPE ELECTRONIC BLOCK PROTECTOR JUNCTION BOX BLUE rabweb.com Visit our website for product info Easy Installation & Product Help CUSTOMER SHOULD CONNECT ONLY AFTER FINISHING WIRING TO AC POWER. BATTERY COULD HAVE CHARGE & SHOCK. INVERTER CONNECTOR: CONNECT ONLY AFTER AC SUPPLY POWER IS CONNECTED RAB LABEL - ADD 2' Flex Conduit Whip ORANGE - BLACK STRIPE WHITE - RED STRIPE EMERGENCY LED DRIVER BSL17C-C2 BODINE YELLOW - BLACK STRIPE WHITE WHITE - BLACK STRIPE LED DRIVER 120V - 277V Emergency Ballast and AC Ballast must be fed from the same circuit WIRING DIAGRAM for EMERGENCY OPERATION at 120V - 277V + RAB LABEL ADD BLACK RAB LABEL ADD IF NOT SWITCHED, THEN CAP TOGETHER JUNCTION BOX CONNECT TO MAIN POWER UNSWITCHED SWITCHED COMMON GROUND WHITE Northvale, New Jersey 07647 USA BROWN BROWN VIOLET VIOLET BLACK YELLOW BLUE BLACK RED Tech Help Line Call our experts 888 RAB-1000 YELLOW TP WHITE BLACK WHITE RED + BLUE OR BLACK - BLACK RED 8" Flex Conduit Whip LED TRIM MODULE - BLACK email Answered promptly sales@rabweb.com SWITCH PLATE WITH INTEGRAL TEST SWITCH (INCLUDED) SWITCH BOX (BY OTHERS) YELLOW - BLACK STRIPE ELECTRONIC BLOCK PROTECTOR JUNCTION BOX BLUE rabweb.com Visit our website for product info Easy Installation & Product Help CUSTOMER SHOULD CONNECT ONLY AFTER FINISHING WIRING TO AC POWER. BATTERY COULD HAVE CHARGE & SHOCK. INVERTER CONNECTOR: CONNECT ONLY AFTER AC SUPPLY POWER IS CONNECTED ©2012 RAB LIGHTING Inc. NDIC6 EM IN 1215 RED RAB LABEL - ADD 2' Flex Conduit Whip ORANGE - BLACK STRIPE WHITE - RED STRIPE EMERGENCY LED DRIVER BSL17C-C2 BODINE YELLOW - BLACK STRIPE WHITE WHITE - BLACK STRIPE BLACK LED DRIVER 120V - 277V Emergency Ballast and AC Ballast must be fed from the same circuit TP CONNECT TO MAIN POWER UNSWITCHED SWITCHED COMMON GROUND Thermal Protector RAB LABEL ADD BLACK RAB LABEL ADD IF NOT SWITCHED, THEN CAP TOGETHER JUNCTION BOX WIRING DIAGRAM for EMERGENCY OPERATION at 120V - 277V with Thermal Protector +