PRESET DIMMING CONTROLS ® GRX-4000 Control Units rev 4000-1a 7.20.00 GRX-4000 Control Units Preset Controls • 4 preset lighting scenes and off for up to 24 zones, accessible from Control Unit faceplate. • 12 additional scenes stored in Control Unit, accessible via Wallstations and/or Control Interfaces. • Light levels fade smoothly between scenes. Fade time: 0-59 seconds or 1-60 minutes. Can be set differently for each scene. Cover (shown open) Key Design Features • Meets IEC 801-2. Tested to withstand 15kV electrostatic discharge without damage or memory loss. • Provides power failure memory: Automatically restores lighting to scene selected prior to power interruption. • Has faceplate that snaps on with no visible means of attachment. Base Zone Infrared Receiver Scene Selection Buttons DESCRIPTION S P E C I F I C AT I O N S • Provide pushbutton recall of four preset lighting scenes. • Control virtually any light source. • Provide lockout options to prevent accidental changes. • Include built-in infrared receiver for operation with an optional remote control. Operating Voltage • Low-voltage type Class 2 (PELV), 12VDC to 24VFW. • Lightning Strike Protection: Meets ANSI/IEEE standard 62.41-1980. Can withstand voltage surges of up to 6000V and current surges up to 3000A. Models available to: • Control two to 24 zones of lighting. • Provide easy setup of preset lighting scenes: GRX-4100 Control Units provide standard setup via pushbuttons on the Control Unit. GRX-4500 Control Units provide optional setup via a PC, including setting lighting levels in 1% increments. Sources/Load Types Operates sources with a smooth continuous Square Law dimming curve or on a full conduction non-dim basis via GP and LP Dimming Panels and XP SoftswitchTM Panels. System Communications and Capacities Low-voltage type Class 2 (PELV) wiring connects Control Units, Wallstations, and Control Interfaces: • You can link up to 8 Control Units to control up to 64 zones. • You can add up to 16 total Wallstations and Control Interfaces for a total of 24 control points. Environment • 32-104°F (0-40°C). Relative humidity less than 90% non-condensing. GRX-4000 Control Units work with: • GRAFIK Eye Wallstations • GP and LP Dimming Panels • XP SoftswitchTM Panels ® JOB NAME: JOB NUMBER: SPECIFICATION SUBMITTAL MODEL NUMBERS: Page PRESET DIMMING CONTROLS ® GRX-4000 Control Units rev 4000-2a 7.20.00 H OW TO B U I L D A M O D E L N U M B E R Number of Zones (2,3,4,6,8,16, or 24) Standard Prefix for GRAFIK Eye Series 4000 Control Units Color Option GRX-4506-T-WH Set up method 1 for standard via front panel 5 for PC setup Cover Options A for Opaque T for Translucent Black MODELS NUMBER OF ZONES STANDARD SETUP MODEL NUMBER PC SETUP 2 3 4 6 8 16 24 GRX-4102-_-__ GRX-4103-_-__ GRX-4104-_-__ GRX-4106-_-__ GRX-4108-_-__ GRX-4116-_-__ GRX-4124-_-__ GRX-4502-_-__ GRX-4503-_-__ GRX-4504-_-__ GRX-4506-_-__ GRX-4508-_-__ GRX-4516-_-__ GRX-4524-_-__ C OV E R O P T I O N S Opaque A Cover and Base will match. Translucent Black T Black cover and your choice of base color. BA S E C O L O R S Matte Finishes Standard – Ships in 48 hours White WH Ivory IV Beige BE Gray GR Brown BR Black BL Gloss Finishes Ships in 4 to 6 weeks Cover Choice: A only White WH Light Almond GLA Almond GAL Ivory GIV Metal Finishes Cover Choice: T only Bright Brass BB Bright Chrome BC Bright Nickel BN Satin Brass SB Satin Chrome SC Satin Nickel SN Antique Brass QB Antique Bronze QZ Anodized Aluminum Clear CLA Black BLA Brass BRA Custom Controls, color matching, and engraving available, Ships in 4 to 6 weeks ® JOB NAME: JOB NUMBER: SPECIFICATION SUBMITTAL MODEL NUMBERS: Page PRESET DIMMING CONTROLS ® GRX-4000 Control Units rev 4000-3a 7.20.00 DIMENSIONS AND MOUNTING MODEL 2-Zone: GRX-4102 GRX-4502 3-Zone: GRX-4103 GRX-4503 4-Zone: GRX-4104 GRX-4504 6-Zone: GRX-4106 GRX-4506 8-Zone: GRX-4108 GRX-4508 16-Zone: GRX-4116 GRX-4516 24-Zone: GRX-4124 GRX-4524 1 SIDE VIEW ZONE 4ZONE ZONE 1 5 FADE ZONE 6 TEMPORARY F ZONES M S MASTER ZONE 4 ZONE ZONE 1 5 FADE ZONE 6 5/16" (8mm) TEMPORARY F ZONES M S MASTER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FADE 1 15/16" (49mm) TEMPORARY F ZONES M S MASTER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FADE TEMPORARY F ZONES M S MASTER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FADE 4 9/16" (116mm) TEMPORARY F ZONES M S MASTER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FADE TEMPORARY F ZONES M S MASTER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FADE TEMPORARY F ZONES M S MASTER WALLBOX1 U.S. SIZE A B C 4 5/16" (123mm) 1 13/16" (46mm) 5.56" (141mm) 2 Gang 3.5" (89mm) 6 11/16" (168mm) 3 5/8” (92mm) 7.25” (184mm) 3 Gang 3.5" (89mm) 8 5/16” (208mm) 5 7/16” (138mm) 8.94” (227mm) 4 Gang 3.5" (89mm) 8 5/16” (208mm) 5 7/16” (138mm) 8.94” (227mm) 4 Gang 3.5" (89mm) 8 5/16” (208mm) 5 7/16” (138mm) 8.94” (227mm) 4 Gang 3.5" (89mm) 8 5/16” (208mm) 5 7/16” (138mm) 8.94” (227mm) 4 Gang 3.5" (89mm) 8 5/16” (208mm) 5 7/16” (138mm) 8.94” (227mm) 4 Gang 3.5" (89mm) DEPTH Can be ordered from Lutron as Part Number 241-519 (1 Gang gangable boxes). A B 3 5/16" (85mm) C ® JOB NAME: JOB NUMBER: SPECIFICATION SUBMITTAL MODEL NUMBERS: Page PRESET DIMMING CONTROLS ® GRX-4000 Control Units rev 4000-4a 7.20.00 L OW- VO LTAG E C L A S S 2 ( P E LV ) W I R I N G Pull low-voltage Class 2 (PELV) wiring for system communications. • Must be daisy-chained. • Must be less than 2000 feet (600m). • Must run seperately from line (mains) voltage. Dimming Panel Control Interface Control Unit Panel-to-Panel wiring1 Include one extra #18AWG (1.0mm2). Used as a “sense line” for emergency (essential) lighting. Wallstations Four wires1 for low-voltage type Class 2 (PELV) • Two #12 AWG (2.5mm2) conductors for control wiring. • One shielded, twisted pair #18 AWG (1.0mm2) for data link. 1 If you use Lutron cable, you can use smaller gauge wires. • If your total system is less than 500 feet (150m), you can use GRX-CBL-346S: - Two #18AWG (1.0mm2) for power. - One twisted, shielded pair #22AWG (.625mm2) for data link. - No “sense line” included - add your own #18AWG (1.0mm2). • If your total system is 500 to 2000 feet (150 to 600m), you can use GRX-CBL-46L: - Two #12AWG (2.5mm2) for power. - One twisted, shielded pair #22AWG (.625mm2) for data link. - One #18AWG (1.0mm2) for sense line between Panels. • Lutron has also approved smaller gauge cable from Belden, Liberty, Alpha, and Signature. Ask for Lutron GRAFIK Eye Cable. ® JOB NAME: JOB NUMBER: SPECIFICATION SUBMITTAL MODEL NUMBERS: Page PRESET DIMMING CONTROLS ® GRX-4000 Control Units rev 4000-5a 7.20.00 C L A S S 2 ( P E LV ) T E R M I N A L C O N N E C T I O N S Connect Drain/Shield as shown. Terminate only at Power Panel if Drain Terminal is provided. It is easiest to connect the bare drain wires and cut off the outside shield throughout the control link. Lutron recommends you make all connections in the Control Unit’s wallbox. Remote connections must be in a switchbox or junction box with a maximum wire length of 8 ft. (2.5m) from the link to the connected unit. 1234D5 Power Panel 1 2 3 4 D 5 Link Link Common Power A BC Data B OK MUX Common Drain Sense MUX +24V MUX Data A OK (1) shielded, twisted pair #18 AWG (1.0 mm2) for data link 3: MUX 4: MUX D: Drain/Shield D D SSA CU WIRE SSA RTN ONLY DO NOT USE 2 IN, OUT 1 IN, OUT DO NOT USE Circuit Selector Black Blue MUX (4) IN MUX (3) IN MUX (4) OUT MUX (3) OUT Drain USA: CLASS 2 IEC: PELV C MUX Drain 1 2 3 4 D 5 To additional Wallstations/Control Interfaces (16 maximum) (2) #12 AWG (2.5mm2) for control wiring 1: Common 2: 24VFW 123456 Drain 44 33 22 11 Wallstations/ Control Interfaces Rear View of GRX-4103 Control Unit NTGRX-1S (10 Maximum) ® JOB NAME: JOB NUMBER: SPECIFICATION SUBMITTAL MODEL NUMBERS: Page