POWER INTERFACES ® ELVI rev elvi-1a 7.20.00 ELVI Electronic Low-Voltage Interface DESCRIPTION • Lets GRX-3000 Control Units and LP Dimming Panels dim electronic transformer-supplied low-voltage lighting. • Provides power and dimming for one zone. • Models available for 120V, 220 -240V (non CE), 230V (CE) or 100V input power. • Works with Lutron’s GRX-3000 Control Units/LP Dimming Panels/HomeWorks Remote Power Panels/Neutral-referenced fluorescent wallbox dimmers by Lutron. S P E C I F I C AT I O N S Power • Input power: 120V, 220-240V (non CE), 230V (CE), or 100V. All voltages 50/60 Hz, phase-to-neutral. • Load (output) power: Phase independent of Control Unit. Sources/Load Types • Operates electronic low-voltage lighting with a smooth continuous Square Law dimming curve or on a full conduction non-dim basis. • – Does not affect sound rating of electronic transformers. • – Does not cause lights to flicker or interact anywhere in dimming range. • – Dims to 0% (blackout). • Works only with electronic (solid-state) low-voltage transformers manufacturerapproved for reverse-phase control dimming. • Can handle incandescent and electronic low-voltage sources on the same zone. You can use up to 30% of the ELVI’s capacity for incandescent lighting. Key Design Features Patented RTISSTM circuitry compensates in real time for incoming line voltage variations: No visible flicker with +/-2% change in RMS voltage/cycle and +/-2% Hz change in frequency/second. Terminals Accept up to two #12 AWG (2.5mm2). Environment 32-104°F (0 - 40°C). Relative humidity less than 90% non-condensing. Mounting Surface or recess mount indoors only. You can use two ELVI Interfaces on a zone for double the capacity. Use the HP Dimming Module System for zones that exceed the ELVI's capacity. ® JOB NAME: JOB NUMBER: M O D E L S A N D C A PAC I T I E S INPUT POWER CAPACITY MODEL NUMBER 120V 1000W/VA ELVI-1000 220-240V (non CE) 1200W/VA NGRX-ELVI-AU-WH 230V (CE) 1200 W/VA NGRX-ELVI-CE-WH 100V 1000W/VA NGRX-ELVI-JA-WH SPECIFICATION SUBMITTAL MODEL NUMBERS: Page POWER INTERFACES ® ELVI rev elvi-2a 7.20.00 Recess Mount with Faceplate DIMENSIONS AND MOUNTING Recess or surface mount in 2-gang U.S. wallbox 3.5" (89mm) deep. Indoors only. • ELVI Interface generates heat! – Mount only where ambient temperature – is 32-104°F (0-40°C). – Mount with arrows facing up to ensure – adequate cooling. – Allow 4.5" (114mm) above and below – unit and between faceplates when – mounting several in a vertical layout. – For better heat dissipation, surface – mount without faceplate. • Mount so line (mains) voltage wiring is at least 6 feet (1.8m) from sound or electronic equipment and wiring. • Mount Interface within 7° of true vertical. Side View 4" (100mm) Surface Mount without Faceplate 4 9/16" (116mm) 1 7/8" 11/16" (48mm) (17mm) 2 Gang U.S. Wallbox ® JOB NAME: JOB NUMBER: SPECIFICATION SUBMITTAL MODEL NUMBERS: Page POWER INTERFACES ® ELVI rev elvi-3a 7.20.00 WIRING • Pull #12 AWG (2.5mm2) Copper (CU) wires (75°C minimum) for input power and load circuit. • Strip 1/2" (12mm) insulation from wires before connecting. • Run separate neutral for load circuit. No common neutrals. Neutral N terminal is for Control Unit, not the load neutral. Single Power Feed The ELVI Interface may be on the same circuit as the Control Unit only if the total load does not exceed the rating of the breaker. CU WIRE ONLY 4 3 2 1 USA: Class 2 IEC: PELV NEUTRAL HOT/LIVE SSA ZONE 3 ZONE 2 ZONE 1 CLASS 2 Hot/Live Feed from Distribution Neutral Panel CONTROL NEUTRAL DHOT OUT HOT IN Rear View of PB GRX-3103 Control Unit Load Neutral Multiple Power Feeds The load breaker/MCB can be on a different phase than the control breaker/MCB. CU WIRE ONLY 4 3 2 1 USA: Class 2 IEC: PELV NEUTRAL HOT/LIVE SSA ZONE 3 ZONE 2 ZONE 1 CLASS 2 Hot/Live Neutral CONTROL NEUTRAL DHOT OUT HOT IN Rear View of PB Load Neutral ® JOB NAME: JOB NUMBER: SPECIFICATION SUBMITTAL MODEL NUMBERS: Feed 1 from Distribution Panel GRX-3103 Control Unit Neutral Hot/Live Feed 2 from Distribution Panel Page POWER INTERFACES ® ELVI rev elvi-4a 7.20.00 Two ELVI Interfaces on a Zone NEUTRAL HOT/LIVE SSA ZONE 3 ZONE 2 ZONE 1 CU WIRE ONLY CLASS 2 Hot/Live Feed 1 from Distribution Neutral Panel 4 3 2 1 USA: Class 2 IEC: PELV CONTROL NEUTRAL DHOT OUT HOT IN Rear View of ELVI CONTROL NEUTRAL DHOT OUT HOT IN Rear View of ELVI GRX-3103 Control Unit Load Neutral Neutral Feed 2 from Hot/Live Distribution Panel Load Neutral Neutral Feed 3 from Hot/Live Distribution Panel With Other Lutron Lighting Controls To wire an ELVI Interface to a fluorescent dimmer: • Run a Neutral wire from the control equipment to Neutral on the ELVI. • Run a dimmed hot wire from the control equipment to Control on the ELVI. * Total load on GRX zone = 50W (25 x 2) * Feeds can be from same feeder if total load on breaker does not exceed breaker rating. ® JOB NAME: JOB NUMBER: SPECIFICATION SUBMITTAL MODEL NUMBERS: Page