Fluorescent Wiring Options

advertisement
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
1 Circuit
All lamps wired on one circuit.
8' section: 1 lamp, 1cct.
8' section: 1 lamp, 1cct.
1
1
1
1
8' section: 2 lamp, 1cct.
1
1
1
1
1
1
1
8' section: 2 lamp, 1cct.
1
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
2 Circuit Left/Right (L/R) Switching
Fixture wired for two circuits. Lamps wired left/right in a 2 lamp cross-section.
8' section: 2 lamp, 2cct. with L/R switching (left/right)
1
1
2
2
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
2 Circuit A/B Switching (module to module)
Fixture wired for two circuits. Lamps wired in alternating 4ft modules.
8' section: 1 lamp, 2cct. with A/B switching (module to module)
8' section: 1 lamp, 2cct. with A/B switching (module to module)
2
1
2
1
8' section: 2 lamp, 2cct. with A/B switching (module to module)
8' section: 2 lamp,
2cct. with A/B switching (module
to module)
1
2
11
22
1
2
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
1 Circuit with Emergency / Night Light (EM/NL)
One 4ft module in a one circuit fixture to be wired on a separate circuit.
All lamps in EM/NL module to be wired together. Leads for normal circuit wired to both fixture ends. Leads for
EM/NL circuit exit at EM/NL section only.
8' section: 1 lamp, 1cct. with EM/NL
8' section: 1 lamp, 1cct. with EM/NL
1
EM/NL
1
EM/NL
8' section: 2 lamp, 1cct. with EM/NL
EM/NL
8' section: 2 lamp, 1cct.1with EM/NL
1
1
EM/NL
EM/NL
1
EM/NL
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
2 Circuit Left/Right (L/R) Switching with Emergency / Night Light (EM/NL)
One 4ft module in a two circuit fixture (left/right switching) to be wired on a separate circuit.
All lamps in EM/NL module to be wired together. Leads for normal circuit wired to both fixture ends. Leads for
EM/NL circuit exit at EM/NL section only.
8' section: 2 lamp, 2cct. with L/R switching (left/right) & EM/NL
1
EM/NL
2
EM/NL
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
1 Circuit with Battery Pack*
All lamps wired on one circuit, plus a battery pack is wired to one lamp. A hot lead is connected to the battery
pack and would function as a “trigger” wire when connected to a constant hot by installer. Leads for both
normal circuit and battery pack are wired to fixture ends.
8' section: 1 lamp, 1cct. with Battery Pack
8' section: 1 lamp, 1cct. with Battery Pack
1
1+BP
1
1+BP
8' section: 2 lamp, 1cct. with Battery Pack
8' section: 2 lamp, 1cct. with Battery Pack
1
1
1
1+BP*
1+BP*
1
1 packs are also available upon request.
1
* Multi-lamp battery
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
* Multi-lamp battery packs are also available upon request.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
2 Circuit Left/Right (L/R) Switching with Battery Pack
Fixture wired for two circuits (left/right switching), plus a battery pack is wired to one lamp.
A hot lead is connected to the battery pack and would act as a “trigger” wire when connected to a constant hot by
installer. Leads for both normal circuits and battery pack are wired to fixture ends.
8' section: 2 lamp, 2cct. with L/R switching (left/right) & Battery Pack
1
1
2
2+BP
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
1 Circuit with Emergency / Night Light (EM/NL) & Battery Pack Combo*
One 4ft module in a one circuit fixture to be wired on a separate circuit, in addition, a battery pack is wired to
one lamp. Installer can connect “trigger” wire to EM hot lead if controlled together or wire separately if controlled
independently. All lamps in EM/NL module to be wired together. Leads for normal circuit wired to both fixture
ends. Leads for EM/NL circuit exit at EM/NL section only.
8' section: 1 lamp, 1cct. with EM/NL & Battery Pack Combo
8' section: 1 lamp, 1cct. with EM/NL & Battery Pack Combo
1
EM/NL+BP
1
EM/NL+BP
8' section: 2 lamp, 1cct. with EM/NL & Battery Pack Combo
8' section: 2 lamp, 1cct. with EM/NL & Battery Pack Combo
1
EM/NL
1
1
EM/NL
EM/NL+BP*
1
EM/NL+BP*
*Multi-lamp battery packs available upon request
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
*Multi-lamp battery packs available upon request
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
Fluorescent
120V, 277V or 347V
Fluorescent Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for most configurations.
2 Circuit Left/Right (L/R) Switching with Emergency / Night Light (EM/NL) &
Battery Pack Combo*
One 4ft module in a two circuit fixture (left/right switching) to be wired on a separate circuit, in addition, a battery pack is wired to one lamp. Installer can connect “trigger” wire to EM hot lead if controlled together or wired
separately if controlled independently. All lamps in EM/NL module to be wired together. Leads for normal circuit
wired to both fixture ends. Leads for EM/NL circuit exit at EM/NL section only.
8' section: 2 lamp, 2cct. L/R switching (left/right) with EM/NL & Battery Pack Combo
1
EM/NL+BP*
2
EM/NL
*Multi-lamp battery packs are available upon request
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving 347V, dimming, step-dimming or customer-specified
ballasts, please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
LED
120V or 277V
LED Wiring Options
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
Dimming can be supplied for all fixtures.
1 Circuit
All LED modules wired on one circuit.
8' section: 1cct.
1
1
8' section: 1cct.
8' section:
2cct.(module
with
A/Btoswitching
2 Circuit A/B
Switching
module) (module to module)
1
1
Fixture wired for two circuits. LED board wired in alternating 4ft modules.
1
2
1
2
8' section: 2cct. with A/B switching (module to module)
8' section: 1cct. with EM/NL
8' section: 1cct. with
1 EM/NL
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
EM/NL
Fax: 604-888-2003
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving dimming, step-dimming or customer-specified driver,
please consult factory.
Web: ledalite.com
L0377 - 05.12
Wiring Options - TruGroove
LED
120V or 277V
LED Wiring Options
All luminaires are pre-wired to one
end with1cct.
quick-wire connectors.
8' section:
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
1
Dimming can be supplied for all fixtures.
1
8' section: 2cct. with A/B switching (module to module)
1 Circuit with Emergency / Night Light (EM/NL)
One 4ft module in a one circuit fixture
1 to be wired on a separate circuit.
2
All LED boards in EM/NL module to be wired together. Leads for normal circuit wired to both fixture ends. Leads for
EM/NL circuit exit at EM/NL section only.
8' section: 1cct. with EM/NL
EM/NL
1
8' section: 1cct. with BP
1+ BP
1
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving dimming, step-dimming or customer-specified driver,
please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
1
1
Wiring Options - TruGroove
LED
120V or 277V
LED Wiring Options
8' section: 2cct. with A/B switching (module to module)
All luminaires are pre-wired to one end with quick-wire connectors.
Each circuit has its own neutral conductor supplied. All circuits are clearly labeled at each end.
All wiring options can be ordered with 1 or 2 circuit thru wiring to fixture ends.
1
Dimming can be supplied for all fixtures.
2
8' section:
1 Circuit with
Battery 1cct.
Pack with EM/NL
Leads for normal circuit and BP circuit wired to fixture ends.
1 together.
All LED boards in BP module to be wired
EM/NL
8' section: 1cct. with BP
1+ BP
1
Some combinations and exceptions may not be shown.
For the most up to date information, especially for projects
involving dimming, step-dimming or customer-specified driver,
please consult factory.
©2012 Philips Ledalite
Phone: 604-888-6811
Toll Free Fax: 1-800-665-LEDA (5332)
Fax: 604-888-2003
Web: ledalite.com
L0377 - 05.12
Download