temporary power

advertisement
MIDWEST ELECTRIC PRODUCTS, INC
TEMPORARY
POWER
Site-Power
™
®
QUALITY WEATHERPROOF
ELECTRICAL EQUIPMENT
TEMPORARY POWER
The Midwest Way
TM
Site-Power makes sense for you. Completely factoryassembled, factory-wired, and factory-tested. Site-Power TM
comes to the construction job site ready for work. All you do
is mount it, connect it, and it’s ready to use … over and over
again.
Site-PowerTM eliminates:
• worries about safety
• worries about theft
• worries about vandalism
• worries about weather
• worries about durability
• worries about code-violations
TM
Just pick up Midwest’s Site-Power and you’re ready to go!
Use it job, after job…
U039G
Figure Your Savings by Using Site-Power on Your Next Job:
TM
MIDWEST
OR DO-IT-YOURSELF
ALL-IN-ONE DESIGN
• Fully assembled and prewired.
• Includes breakers, receptacles and meter socket
(if required).
• Available with GFI circuit breakers.
• Eliminates construction hold-ups due to red tag
code violations. Conforms to NEC and NEMA
standards. Most models UL listed.
• Weatherproof, heavy steel construction holds up
job after job.
• Dead front design provides maximum safety.
• Locking cover guards against vandalism and
unauthorized use.
METER SOCKET
LOAD CENTER AND
BREAKERS
RECEPTACLES AND
BOXES
$
FITTINGS AND WIRE
LABOR
CATALOG NUMBER
CATALOG NUMBER
TOTAL
COST
$
Data Subject To Change Without Notice
TOTAL
COST
$
* See back page for details
TEMPORARY POWER
Application Information
Prior to permanent installation of the service equipment, a means of temporarily supplying power
is required by the various construction trades. Many times, this requires several receptacles,
overcurrent protection and possibly a meter socket and GFCI, all designed for outdoor installation.
Historically, a temporary power set-up included an individual meter socket, a 4-8 circuit load
center, several outlet boxes with receptacles and flip covers, all field nippled together on a 4x4
wood post. Of course, these “systems” did not provide maximum protection against weather and
vandalism, plus, when subjected to normal field use, deteriorated rapidly.
Site-PowerTM construction site equipment from Midwest Electric combines all the required
components in a single enclosure. Completely factory-assembled and factory-tested, Site-PowerTM
comes to the construction job site ready for work. No need to field assemble individual parts,
saving installation time. Site-Power TM protects itself against weather, vandalism, and nuisance
tripping. The single, heavy-gauge NEMA 3R rainproof enclosure is lockable and is engineered
for maximum protection of receptacles, cords, plugs, breakers, and GFCI’s. Site-PowerTM fully
meets the 2002 National Electrical Code and OSHA requirements.
Features and Benefits
Rugged Durability
•
•
•
•
•
All-in-one construction for factory assured terminations
Rolled edge door for cord protection
Continuous duty meter socket with meter guides and reinforced jaws –
ringless and ring type. Utility accepted meter sealing accommodations
Heavy G-90 zinc coated steel with highest quality electro-deposition finish
resists corrosion and fading
Welded flange NEMA 3R construction for lasting service in outdoor
installations
User Safety
•
•
•
Dead front construction prevents accidental contact with live parts
Door has padlock provisions to prevent unauthorized access
Listed by Underwriters Laboratories, a safety plus
Installation Ease
•
•
•
•
•
•
All components factory wired and assembled, reducing installation time
Door removable for installation ease; stay-open position for user
convenience
All terminals accept copper or aluminum wire for added installation flexibility
Wide range of receptacle configurations
Broad range of concentric knock-outs to accommodate varied wiring
needs
All units with 12-2 CuAl equipment ground lug
* See back page for details
R011C010U
Data Subject To Change Without Notice
Featured Models**
20
U010C010
20 20
U010F
S
P
A
C
E
20
U011C010
20 20
S
P
A
C
E
R011C010U
UL MODEL NUMBER RECEPTACLES
Y
Y
Y
U010C010
U010F
U011C010
5-20R2GFI
5-20R2
(2) 5-20R2GFI
Y
U038C010
Y
U039G
6-20R,
(2) 5-20R2GFI
L6-30R,
(2)L5-20R
Y
U054C
Y
U055C033
Y
U055G
Y
R011C010U+
(2) 5-20R2GFI
Y
M038CB1033
6-20R
5-20R2GFI
Y
R038C010U+
6-20R
(2) 5-20R2GFI
Y
R055C033U+ ~
Y
R076C033+
14-50R
5-20R2GFI
14-50R
(2) 5-20R2GFI
14-50R
5-20R2GFI
5-20R2
50
S
P
A
C
E
20 20
GFI
20
20
GF I
U055C033
S
P
A
C
E
50
GFI
20
50
U055G
50 20 20
GFI
S
P
A
C
E
S
P
A
C
E
M038CB1033
CIRCUIT
PROTECTION
CB120
FH2
(2) CB120,
SPACE CB120
CB220
(2) CB120
GFI230,
(2) GFI120,
(6) SPACE CB120
CB250
SPACE CB120
GFI250
CB120
CB250
GFI120
(2) CB120
SPACE CB120
GFI220
(2) CB120
SPACE CB120
CB220
(2) CB120
SPACE CB120
GFI250
CB120
GFI250
(2) CB120
SPACE CB120
50
U054C
20 20 20
GFI
14-50R
S
P
A
C
E
U038C010
20
U039G
20 20
R038C010U
R055C033U
R076C033
WIRE CABINET HUB
LOAD &
UNIT STD.
AMP VOLTS RANGE * SIZE OPENING NEUTRAL BAR WT. PKG.
20
120
B
6X9
Y
——
7
4
20
120
E
5X7
Y
——
4.5
4
70 120/240
P
6 X 14
Y
LC33N
7
4
100 120/240
U
9 X 17
Y
LC55N1
15
1
200 120/240
U
14 X 21
Y
LC1212PC
28
1
70 120/240
O
6 X 14
Y
LC33N7
10
4
70 120/240
P
6 X 14
Y
LC33N7
10
4
70 120/240
P
6 X 14
Y
LC33N7
10
4
100 120/240
AA
9 X 30U
Y
LC33N1
21
1
100 120/240
AA
14 X 26
Y
LC55N1
33
1
100 120/240
AA
9 X 30U
Y
LC55N1
25
1
70 120/240
AA
9 X 30U
Y
LC33N1
23
1
90 120/240
AA
9 X 30
Y
LC55N1
24
1
* See reverse for further inf ormation.
= Edis on Plug Fuse Base (Fuse s Not Included)
+ Also Availa ble in Ring Type. Repla ce R with M.
~ Florida Metering G roup (FMG) a pprov ed model av ailable . Orde r with “FMG” after m odel; Consult Manufa cturer
MEP F-TP 04
Data Subject To Change Without Notice
** Additional Basic And Custom Models Available, Consult Manufacturing Representative For Further Details
Technical Information
REPLACEMENT
METER
CABINET
SOCKET
SIZE
MODEL
NUMBER
CABINET DIMENSIONS
HEIGHT WIDTH
DEPTH
A
B
C
ENCLOSURE
STYLE
KNOCKOUT
FIGURE
M011C010U
MSM100EZ
9 X 30U
B
30”
9-3/4”
5-3/16”
2
M038CB1033
MSM10014
14 X 26
B
26-1/4”
14-3/4”
4-9/16”
4
M038C010U
MSM100EZ
9 X 30U
C
30”
9-3/4”
5-3/16”
3
M055C033U
MSM100EZ
9 X 30U
C
30”
9-3/4”
5-3/16”
3
M076C033
MSM100930
9 X 30
B
30”
9-3/4”
5-3/16”
2
R011C010U
MSM100EZ
9 X 30U
B
30”
9-3/4”
5-3/16”
2
R038C010U
MSM100EZ
9 X 30U
C
30”
9-3/4”
5-3/16”
3
R055C033U
MSM100EZ
9 X 30U
C
30”
9-3/4”
5-3/16”
3
R076C033
MSM100930
9 X 30
B
30”
9-3/4”
5-3/16”
2
U010C010
——
6 X 14
A
14-3/8”
6-3/4”
5-3/16
1
U010F
——
5 X7
A
7-1/8"
5-3/4"
5-3/16"
5
U011C010
——
6 X 14
A
14-3/8"
6-3/4"
5-3/16"
1
U038C010
——
9 X 17
A
17-3/8"
9-3/4"
5-3/16"
2
U039G
——
14 X 21
A
21-3/8”
14-3/4”
5-3/16”
6
U054C
——
6 X 14
A
14-3/8"
6-3/4"
5-3/16"
1
U055C033
——
6 X 14
A
14-3/8"
6-3/4”
5-3/16"
1
U055G
——
6 X 14
A
14-3/8"
6-3/4”
5-3/16"
1
Wire Range Tables
TABLE AA
TABLE P
TABLE O
Copper
Aluminum
Solid Strand Solid Strand
Connector
Copper
Aluminum
Solid Strand Solid Strand
Line
–––
6-1/0
–––
6-1/0
Line
14-8
14-2
12-8
12-2
Load
14-10
14-10
–––
–––
Load
–––
–––
–––
–––
Connector
Neutral
Large
H ol e
Neutral
Smal l
H ol e
Equip.Grnd.
12-8
12-1/0
10-8
10-1/0
Neutral
End
H ole
Si de
H ole
14-8
14-4
12-8
12-4
Neutral
12-8
12-2
12-8
12-2
Equip.Grnd.
TABLE U
14-8
14-2
12-8
12-2
Aluminum
Aluminum
Solid
Strand Solid Strand
Line
14-8
14-1/0
12-8
12-1/0
Load
14-10
14-10
–––
–––
14-8
14-2
12-8
12-2
Neutral
E nd
Hol e
Side
Hol e
14-8
14-4
12-8
12-4
12-8
12-2
12-8
12-2
14-8
14-4
12-8
12-4
Neutral
12-8
12-2
12-8
12-2
Equip.Grnd.
TABLE V
Copper
Copper
Connector
TABLE E
Copper
Aluminum
Connector
Solid
Strand Solid Strand
Connector
Solid
Strand Solid
Strand
Line
14-8
14-1/0
12-8
12-1/0
Line
14-8
14-1/0
12-8
12-1/0
Load
14-10
14-10
–––
–––
Load
–––
–––
–––
–––
Copper
Aluminum
Connector
Solid
Strand
Solid
Strand
Line
14-10
14-10
–––
–––
Load
14-10
14-10
–––
–––
Neutral
Large
H ole
12-8
12-1/0
10-8
10-1/0
Neutral
Large
H ole
12-8
12-1/0
10-8
10-1/0
Neutral
Sm al l
H ole
14-8
14-4
12-8
12-4
Neutral
Sm all
H ole
14-8
14-4
12-8
12-4
Neutral
14-10
14-10
–––
–––
Equip.Grnd.
12-8
12-2
12-8
12-2
Equip.Grnd.
12-8
12-2
12-8
12-2
Equip.Grnd.
12-8
12-2
–––
–––
MEP F-TP0 4
Data Subject To Change Without Notice
Technical Information
Cabinet Dimensions
(FIG. A)
(FIG. B)
(FIG. C)
C
B
B
B
C
C
Knockout Configurations
(FIG. 1)
(FIG. 2)
(FIG. 3)
A = 1/2"
B = 1", 1-1/4", 1-1/2"
C = 1-1/4", 1-1/2", 2", 2 1/2"
G
G
G
G
N G
G
G
G
G
(FIG. 4)
D
G
D = 3/4", 1", 1-1/4"
G
B B
G W
(FIG. 5)
E = 3/4"
B
F = 1/2", 3/4"
G = 1/2", 3/4", 1"
(FIG. 6)
H = 1/2”, 3/4", 1-1/4"
N = 1/2", 3/4", 1", 1-1/4", 1-1/2"
P = 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2 1/2"
W
C
W
P
A
P P
F
H F
C
C
C
A C
E Q
C
Q = 1"
W = 1/2", 3/4", 1", 1-1/4", 2"
MIDWEST POWER OUTLETS
Portable equipment requiring electricity continues to increase steadily in both number and variety. This
creates the need for conveniently located receptacles to provide power for cord
connected equipment. Midwest Electric Power Outlets provide one or more receptacles,
with or without overcurrent protection, in a single enclosure eliminating the need
for several separately mounted components while providing maximum protection
against weather and normal field use. Additionally, many models are offered that
also include disconnecting, metering, and/or pedestal mounting functions in a single
NEMA 3R enclosure/assembly. Find out more in Midwest’s General Catalog, order
brochure MEPF-PO04 from your local Manufacturer’s Representative, or download
at http://www.midwestelectric.com/marketing
Pictured on cover, left to right: U038C010, M011C010, M055C033.
Contact local manufacterer’s representative for further information on these and other popular models.
Powers the Great Outdoors
©2004, Midwest Electric Products, Inc
PO Box 910, Mankato, MN 56001
(507)345-2505, (507)345-2530 FAX
ME PF-TP04
www.midwestelectric.com
customerservice@midwestelectric.com
Data Subject To Change Without Notice
Download