MIDWEST ELECTRIC PRODUCTS, INC TEMPORARY POWER Site-Power ™ ® QUALITY WEATHERPROOF ELECTRICAL EQUIPMENT TEMPORARY POWER The Midwest Way TM Site-Power makes sense for you. Completely factoryassembled, factory-wired, and factory-tested. Site-Power TM comes to the construction job site ready for work. All you do is mount it, connect it, and it’s ready to use … over and over again. Site-PowerTM eliminates: • worries about safety • worries about theft • worries about vandalism • worries about weather • worries about durability • worries about code-violations TM Just pick up Midwest’s Site-Power and you’re ready to go! Use it job, after job… U039G Figure Your Savings by Using Site-Power on Your Next Job: TM MIDWEST OR DO-IT-YOURSELF ALL-IN-ONE DESIGN • Fully assembled and prewired. • Includes breakers, receptacles and meter socket (if required). • Available with GFI circuit breakers. • Eliminates construction hold-ups due to red tag code violations. Conforms to NEC and NEMA standards. Most models UL listed. • Weatherproof, heavy steel construction holds up job after job. • Dead front design provides maximum safety. • Locking cover guards against vandalism and unauthorized use. METER SOCKET LOAD CENTER AND BREAKERS RECEPTACLES AND BOXES $ FITTINGS AND WIRE LABOR CATALOG NUMBER CATALOG NUMBER TOTAL COST $ Data Subject To Change Without Notice TOTAL COST $ * See back page for details TEMPORARY POWER Application Information Prior to permanent installation of the service equipment, a means of temporarily supplying power is required by the various construction trades. Many times, this requires several receptacles, overcurrent protection and possibly a meter socket and GFCI, all designed for outdoor installation. Historically, a temporary power set-up included an individual meter socket, a 4-8 circuit load center, several outlet boxes with receptacles and flip covers, all field nippled together on a 4x4 wood post. Of course, these “systems” did not provide maximum protection against weather and vandalism, plus, when subjected to normal field use, deteriorated rapidly. Site-PowerTM construction site equipment from Midwest Electric combines all the required components in a single enclosure. Completely factory-assembled and factory-tested, Site-PowerTM comes to the construction job site ready for work. No need to field assemble individual parts, saving installation time. Site-Power TM protects itself against weather, vandalism, and nuisance tripping. The single, heavy-gauge NEMA 3R rainproof enclosure is lockable and is engineered for maximum protection of receptacles, cords, plugs, breakers, and GFCI’s. Site-PowerTM fully meets the 2002 National Electrical Code and OSHA requirements. Features and Benefits Rugged Durability • • • • • All-in-one construction for factory assured terminations Rolled edge door for cord protection Continuous duty meter socket with meter guides and reinforced jaws – ringless and ring type. Utility accepted meter sealing accommodations Heavy G-90 zinc coated steel with highest quality electro-deposition finish resists corrosion and fading Welded flange NEMA 3R construction for lasting service in outdoor installations User Safety • • • Dead front construction prevents accidental contact with live parts Door has padlock provisions to prevent unauthorized access Listed by Underwriters Laboratories, a safety plus Installation Ease • • • • • • All components factory wired and assembled, reducing installation time Door removable for installation ease; stay-open position for user convenience All terminals accept copper or aluminum wire for added installation flexibility Wide range of receptacle configurations Broad range of concentric knock-outs to accommodate varied wiring needs All units with 12-2 CuAl equipment ground lug * See back page for details R011C010U Data Subject To Change Without Notice Featured Models** 20 U010C010 20 20 U010F S P A C E 20 U011C010 20 20 S P A C E R011C010U UL MODEL NUMBER RECEPTACLES Y Y Y U010C010 U010F U011C010 5-20R2GFI 5-20R2 (2) 5-20R2GFI Y U038C010 Y U039G 6-20R, (2) 5-20R2GFI L6-30R, (2)L5-20R Y U054C Y U055C033 Y U055G Y R011C010U+ (2) 5-20R2GFI Y M038CB1033 6-20R 5-20R2GFI Y R038C010U+ 6-20R (2) 5-20R2GFI Y R055C033U+ ~ Y R076C033+ 14-50R 5-20R2GFI 14-50R (2) 5-20R2GFI 14-50R 5-20R2GFI 5-20R2 50 S P A C E 20 20 GFI 20 20 GF I U055C033 S P A C E 50 GFI 20 50 U055G 50 20 20 GFI S P A C E S P A C E M038CB1033 CIRCUIT PROTECTION CB120 FH2 (2) CB120, SPACE CB120 CB220 (2) CB120 GFI230, (2) GFI120, (6) SPACE CB120 CB250 SPACE CB120 GFI250 CB120 CB250 GFI120 (2) CB120 SPACE CB120 GFI220 (2) CB120 SPACE CB120 CB220 (2) CB120 SPACE CB120 GFI250 CB120 GFI250 (2) CB120 SPACE CB120 50 U054C 20 20 20 GFI 14-50R S P A C E U038C010 20 U039G 20 20 R038C010U R055C033U R076C033 WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS RANGE * SIZE OPENING NEUTRAL BAR WT. PKG. 20 120 B 6X9 Y —— 7 4 20 120 E 5X7 Y —— 4.5 4 70 120/240 P 6 X 14 Y LC33N 7 4 100 120/240 U 9 X 17 Y LC55N1 15 1 200 120/240 U 14 X 21 Y LC1212PC 28 1 70 120/240 O 6 X 14 Y LC33N7 10 4 70 120/240 P 6 X 14 Y LC33N7 10 4 70 120/240 P 6 X 14 Y LC33N7 10 4 100 120/240 AA 9 X 30U Y LC33N1 21 1 100 120/240 AA 14 X 26 Y LC55N1 33 1 100 120/240 AA 9 X 30U Y LC55N1 25 1 70 120/240 AA 9 X 30U Y LC33N1 23 1 90 120/240 AA 9 X 30 Y LC55N1 24 1 * See reverse for further inf ormation. = Edis on Plug Fuse Base (Fuse s Not Included) + Also Availa ble in Ring Type. Repla ce R with M. ~ Florida Metering G roup (FMG) a pprov ed model av ailable . Orde r with “FMG” after m odel; Consult Manufa cturer MEP F-TP 04 Data Subject To Change Without Notice ** Additional Basic And Custom Models Available, Consult Manufacturing Representative For Further Details Technical Information REPLACEMENT METER CABINET SOCKET SIZE MODEL NUMBER CABINET DIMENSIONS HEIGHT WIDTH DEPTH A B C ENCLOSURE STYLE KNOCKOUT FIGURE M011C010U MSM100EZ 9 X 30U B 30” 9-3/4” 5-3/16” 2 M038CB1033 MSM10014 14 X 26 B 26-1/4” 14-3/4” 4-9/16” 4 M038C010U MSM100EZ 9 X 30U C 30” 9-3/4” 5-3/16” 3 M055C033U MSM100EZ 9 X 30U C 30” 9-3/4” 5-3/16” 3 M076C033 MSM100930 9 X 30 B 30” 9-3/4” 5-3/16” 2 R011C010U MSM100EZ 9 X 30U B 30” 9-3/4” 5-3/16” 2 R038C010U MSM100EZ 9 X 30U C 30” 9-3/4” 5-3/16” 3 R055C033U MSM100EZ 9 X 30U C 30” 9-3/4” 5-3/16” 3 R076C033 MSM100930 9 X 30 B 30” 9-3/4” 5-3/16” 2 U010C010 —— 6 X 14 A 14-3/8” 6-3/4” 5-3/16 1 U010F —— 5 X7 A 7-1/8" 5-3/4" 5-3/16" 5 U011C010 —— 6 X 14 A 14-3/8" 6-3/4" 5-3/16" 1 U038C010 —— 9 X 17 A 17-3/8" 9-3/4" 5-3/16" 2 U039G —— 14 X 21 A 21-3/8” 14-3/4” 5-3/16” 6 U054C —— 6 X 14 A 14-3/8" 6-3/4" 5-3/16" 1 U055C033 —— 6 X 14 A 14-3/8" 6-3/4” 5-3/16" 1 U055G —— 6 X 14 A 14-3/8" 6-3/4” 5-3/16" 1 Wire Range Tables TABLE AA TABLE P TABLE O Copper Aluminum Solid Strand Solid Strand Connector Copper Aluminum Solid Strand Solid Strand Line ––– 6-1/0 ––– 6-1/0 Line 14-8 14-2 12-8 12-2 Load 14-10 14-10 ––– ––– Load ––– ––– ––– ––– Connector Neutral Large H ol e Neutral Smal l H ol e Equip.Grnd. 12-8 12-1/0 10-8 10-1/0 Neutral End H ole Si de H ole 14-8 14-4 12-8 12-4 Neutral 12-8 12-2 12-8 12-2 Equip.Grnd. TABLE U 14-8 14-2 12-8 12-2 Aluminum Aluminum Solid Strand Solid Strand Line 14-8 14-1/0 12-8 12-1/0 Load 14-10 14-10 ––– ––– 14-8 14-2 12-8 12-2 Neutral E nd Hol e Side Hol e 14-8 14-4 12-8 12-4 12-8 12-2 12-8 12-2 14-8 14-4 12-8 12-4 Neutral 12-8 12-2 12-8 12-2 Equip.Grnd. TABLE V Copper Copper Connector TABLE E Copper Aluminum Connector Solid Strand Solid Strand Connector Solid Strand Solid Strand Line 14-8 14-1/0 12-8 12-1/0 Line 14-8 14-1/0 12-8 12-1/0 Load 14-10 14-10 ––– ––– Load ––– ––– ––– ––– Copper Aluminum Connector Solid Strand Solid Strand Line 14-10 14-10 ––– ––– Load 14-10 14-10 ––– ––– Neutral Large H ole 12-8 12-1/0 10-8 10-1/0 Neutral Large H ole 12-8 12-1/0 10-8 10-1/0 Neutral Sm al l H ole 14-8 14-4 12-8 12-4 Neutral Sm all H ole 14-8 14-4 12-8 12-4 Neutral 14-10 14-10 ––– ––– Equip.Grnd. 12-8 12-2 12-8 12-2 Equip.Grnd. 12-8 12-2 12-8 12-2 Equip.Grnd. 12-8 12-2 ––– ––– MEP F-TP0 4 Data Subject To Change Without Notice Technical Information Cabinet Dimensions (FIG. A) (FIG. B) (FIG. C) C B B B C C Knockout Configurations (FIG. 1) (FIG. 2) (FIG. 3) A = 1/2" B = 1", 1-1/4", 1-1/2" C = 1-1/4", 1-1/2", 2", 2 1/2" G G G G N G G G G G (FIG. 4) D G D = 3/4", 1", 1-1/4" G B B G W (FIG. 5) E = 3/4" B F = 1/2", 3/4" G = 1/2", 3/4", 1" (FIG. 6) H = 1/2”, 3/4", 1-1/4" N = 1/2", 3/4", 1", 1-1/4", 1-1/2" P = 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2 1/2" W C W P A P P F H F C C C A C E Q C Q = 1" W = 1/2", 3/4", 1", 1-1/4", 2" MIDWEST POWER OUTLETS Portable equipment requiring electricity continues to increase steadily in both number and variety. This creates the need for conveniently located receptacles to provide power for cord connected equipment. Midwest Electric Power Outlets provide one or more receptacles, with or without overcurrent protection, in a single enclosure eliminating the need for several separately mounted components while providing maximum protection against weather and normal field use. Additionally, many models are offered that also include disconnecting, metering, and/or pedestal mounting functions in a single NEMA 3R enclosure/assembly. Find out more in Midwest’s General Catalog, order brochure MEPF-PO04 from your local Manufacturer’s Representative, or download at http://www.midwestelectric.com/marketing Pictured on cover, left to right: U038C010, M011C010, M055C033. Contact local manufacterer’s representative for further information on these and other popular models. Powers the Great Outdoors ©2004, Midwest Electric Products, Inc PO Box 910, Mankato, MN 56001 (507)345-2505, (507)345-2530 FAX ME PF-TP04 www.midwestelectric.com customerservice@midwestelectric.com Data Subject To Change Without Notice