27-17 REG ** 14-04-22 -R3 - RENEWABLE ENERGY GENERATION CERTIFIED CUSTOMER PANELBOARD REG SCADA REVENUE METER INSTALL BY METERING OPERATED UTILITY SUPPLY INSTALL BY METERING WARNING WARNING CUSTOMER CUSTOMER MAIN DISTRIBUTED GENERATION BACKFEED BACKFEED POSSIBLE POSSIBLE POSSIBLE LOAD SIDE REG LOAD SIDE WARNING REG * PHONE LINE POSSIBLE LOAD BREAK CABINET REQUIRED SWITCH DISTRIBUTED GENERATION AUTOMATED LOADBREAK LOADBREAK SWITCH SWITCH > 10 KW BACKFEED POSSIBLE DG3 LOAD BREAK DG2 (NOTE 1 & 2) SWITCH REG DISTRIBUTED GENERATION BACKFEED SWITCH WARNING DISTRIBUTED GENERATION BACKFEED LINE SIDE REVENUE METER LOAD BREAK MAIN REG WARNING DISTRIBUTED GENERATION (NOTE 1 & 2) DG1 (NOTE 1 & 2) WARNING DISTRIBUTED (NOTE 1) GENERATION BACKFEED INSTALL BY POSSIBLE INSTALL BY METERING METERING DG4 REG LINE SIDE WARNING DISTRIBUTED GENERATION FIG. 1 - 3 PHASE FIT UP TO 200 A BACKFEED POSSIBLE CUSTOMER PANELBOARD T385 SCADA UTILITY SUPPLY OPERATED INSTALL BY METERING WARNING REG REVENUE DISTRIBUTED GENERATION BACKFEED POSSIBLE CUSTOMER CUSTOMER MAINREG MAIN REVENUE METER LOAD BREAK CABINET LINE SIDE METERING AND REG MONITORING LOAD SIDE SWITCH WARNING DISTRIBUTED GENERATION SWITCH DG3 BACKFEED LOAD BREAK POSSIBLE SWITCH (NOTE 1 & 2) LOAD SIDE REG LOAD BREAK A B * PHONE LINE REQ’D REG AUTOMATED LOADBREAK LOADBREAK SWITCH SWITCH DG2 DG1 (NOTE 1 & 2) (NOTE 1 & 2) WARNING DISTRIBUTED GENERATION BACKFEED POSSIBLE (NOTE 1) INSTALL BY METERING DG4 REG LINE SIDE A - POWER QUALITY METERIMG REQ’D FOR 250 KW AND ABOVE NOTE: CENTRAL METERING PANEL B - RENEWABLE ENERGY METER 1. A ADDITIONAL LOAD BREAK SWITCH WILL BE REQUIRED WHEN THE FIRST REG LOAD BREAK SWITCH IS LOCATED MORE THAN 25 FT FROM THE CUSTOMER MAIN (SEE NOTE 5) SWITCH OR THE REG LOAD BREAK SWITCH IS LOCATED IN ANOTHER ROOM. CUSTOMER IS RESPONSIBLE FOR LABELLING THE REG LOAD BREAK SWITCHES AS SHOWN. 2. ALL REG LOAD BREAK SWITCHES MUST HAVE PROVISION FOR PADLOCKING IN THE FIG. 2 - 3 PHASE FIT ABOVE 200 A APPROVED IN ACCORDANCE WITH REGULATION 22/04 OPEN POSITION. DATE 3. FIT WARNING LABELS (T385) TO BE INSTALLED BY HOB PERSONNEL. 5. REFER TO STD. 27-120 AND STD. 27-121 FOR CMP ENCLOSURE DETAILS. R E V I S I O N - SHOWED REG. DG3 SW, DG2 SW 4. AUTOMATED LOADBREAK SWITCH DG2 TO BE OPERATED REMOTELY BY HOB. 14-04-22 AND REG REVENUE METERING INSIDE A CMP ENCLOSURE CHECKED: APPROVED: ORIGINAL ISSUED: MARCH 02, 2012 TYPICAL METER / SWITCH ARRANGEMENT FOR RENEWABLE ENERGY GENERATION ( FOR MORE THAN 25 FT BETWEEN CUSTOMER MAIN & FIRST REG SWITCH ) APPVD