arris.com
RF over Glass (RFoG)
RFoG and RFPON ONU (R‐ONU)
CPE Powering Solutions
FEATURES
• Support ARRIS RFoG and RFPON ONUs (R‐ONUs)
• AC Wall Adapters
– 120 VAC (nominal) to 12 VDC with USA style mains connector
– 230 VAC (nominal) to 12 VDC with European style mains connector
– 100 VAC (nominal) to 12 VDC with Japan style mains connector
– 100‐240 VAC to 15VDC Universal Adapter with interchangeable connectors for USA, Europe, and United Kingdom (UK) mains styles
–
PS1921W‐00
PS1921W‐10
"F" type DC output connectors
• Uninterruptible Power Supply
– 12 VDC output on “F” connector
– 120 or 230 VAC input
– 7.2 AH backup battery
• Meet current EMC, Safety, and Environmental requirements
• CP1921W‐10 Meets USA DOE Class VI Efficiency Specifications
• High reliability for long‐term service
PS1911
PS1811‐UPS
PRODUCT OVERVIEW
ARRIS RFoG Optical Network Unit (R‐ONU) CPEs all require external power for operation. Separately sold powering solutions include compact low‐cost high reliability wall‐mounted AC‐to‐DC adapters with 12 VDC or 15VDC outputs and standard female "F" type connectors having nominal AC input voltages of 100, 120, and 230 Volts. Input mains connectors fit USA, EU, and UK style connectors common to various world‐wide geographical regions, and US NEMA mains plugs offer a wall plate mounting lug that ensures a secure installation. The required power supply depends on the R‐ONU CPE device being powered.
Ask us about the complete Access Technologies Solutions portfolio:
Fiber‐Deep
DOCSIS® 3.1
Node Segmentation
RFoG‐RFPON ONU (R‐ONU)
HPON™/RFoG
FTTx
RFoG/RFPON R‐ONU Power Supplies
A battery back‐up Uninterruptible Power Supply (UPS) supporting 100 to 240 VAC input range is also available, for continuous operation during AC power failures is also available. The PS1801B‐00 battery for the UPS is sold separately.
All power supplies feature “F” type female DC connectors for compatibility with the R‐ONU however the PS1921W‐00 also requires a PS1900 ADP 2.1 mm plug‐to‐F‐type adapter, that comes with the R‐ONU CPE. (The PS1921W‐10 does not require this adapter).
Recommended power supplies for ARRIS R‐ONU CPEs:
PS191xW‐00: The part number designates the mains AC connector type. See details below.
• PS1911W includes USA NEMA 1‐15P AC connector with wall‐plate securing lug
• Supports standard R‐ONUs (not OBI‐free)
PS1921W‐xx: Universal AC voltage input range and multi‐country mains connector types
• Supports all R‐ONUs, and are required for OBI‐free versions
• PS1921W‐10:
– Includes USA NEMA 1‐15P AC connector with wall‐plate securing lug
– Meets USA Department of Energy (DOE) Class VI efficiency specifications
– Eliminates PS1900‐ADP DC to F‐type adapter required by the PS1921‐00
PS1811U: Uninterruptable Power Supply (UPS)
• Supports all R‐ONUs CPEs SPECIFICATIONS Characteristics
Specification
AC Wall Adapters
PS1911W‐00
120 VAC (nominal) USA type adapter with 12 VDC output on “F” connector
PS1912W‐00
500 mA @ 12 VDC nom. (6 W)
108–132 Vrms
60 Hz
150 mA
NEMA 1‐15P
"F" type‐female
1 kV min (per IEEE/ANSI C62.41)
UL 13210 / CSA C22.2 No. 223‐M91
–10° to +40°C (+14° to +104°F)
–20° to +80°C (–4° to +176°F)
5% to 95% non–condensing
2.3” W x 3.0” H x 2.0” D (5.8 cm x 7.6 cm x 5.0 cm)
1 lb. (0.45 kg)
230 VAC (nominal) EU type adapter with 12 VDC output on “F” connector
Output
Operating input voltage
Operating frequency
Input current, max
AC input connector
DC output connector
Surge protection
Safety
Operating temperature
Storage temperature
Humidity
Dimensions
Weight, typ
500 mA @ 12 VDC nom. (6 W)
207–253 Vrms
50 Hz
150 mA
CEE 7/16
"F" type‐female
1 kV min (per EN 61000‐4‐5:2005)
IEC/EN 61558
–10° to +40°C (+14° to +104°F)
–20° to +80°C (–4° to +176°F)
5% to 95% non–condensing
2.3” W x 3.3” H x 2.0” D (5.8 cm x 8.5 cm x 5.1 cm)
1 lb. (0.45 kg)
Output
Operating input voltage
Operating frequency
Input current, max
AC input connector
DC output connector
Surge protection
Safety
Operating temperature
Storage temperature
Humidity
Dimensions
Weight, typ
Ask us about the complete Access Technologies Solutions portfolio:
Fiber‐Deep
DOCSIS® 3.1
Node Segmentation
RFoG‐RFPON ONU (R‐ONU)
HPON™/RFoG
FTTx
RFoG/RFPON R‐ONU Power Supplies
SPECIFICATIONS Characteristics
Specification
AC Wall Adapters
PS1913W‐00
100 VAC (nominal) adapter with 12 VDC output on “F” connector, with PSE Mark for Japan
Output
Operating input voltage
Operating frequency
Input current, max
AC input connector
DC output connector
Surge protection
Safety
Operating temperature
Storage temperature
Humidity
Dimensions
Weight, typ
500 mA @ 12 VDC nom. (6 W)
90–110 Vrms
47 to 63 Hz
150 mA
JIS C8303, Class II
"F" type‐female
1 kV min (per EN 61000‐4‐5:2005)
PSE IEC 61558
–10° to +40°C (+14° to +104°F)
–20° to +80°C (–4° to +176°F)
5% to 95% non–condensing
2.3” W x 3.0” H x 2.0” D (5.8 cm x 7.6 cm x 5.0 cm)
1 lb. (0.45 kg)
PS1921W‐00 Universal Power Supply Kit
Includes mains slide‐on adaptors for USA, Europe, and UK style connectors
Rated input voltage
Operating input voltage
Operating frequency
AC input connectors
DC Output
DC output current
DC output cable/connector
100 ‐240 VAC to 15VDC supports multi‐geography AC voltage standards
90 to 250 VRMS @ 50/60 Hz, 0.6A maximum
50/60 Hz
Three interchangeable adapters: NEMA 1‐15P (NP), CEE 7/16 and BS1363 (USA, EU, and JAPAN styles)
15 VDC nominal, ± 5%
1.5 A max, TA = 0 to +40°C (32° to 104°F)
4.5 ft. (1375 mm) min with 2.1 x 5.5 mm fork (use with the PS1900 ADP adapter, supplied with R‐ONU device)
6 kV combination wave per IEEE/ANSI C62.41
0° to +40°C (32° to 104°F)
‐10° to +75°C (14° to 167°F)
20 to 80 % RH, non condensing
1.85" W x 3.7" H x 1.65" D (4.7 cm x 9.4 cm x 4.2 cm)
0.66 lb. (0.3 kg)
EN 55022: Radiated and Conducted Emission for ITE; EN 55024: Immunity for ITE; 2014/30/EC: Electromagnetic Compatibility (EMC) Directive; IEC 60950‐1: ITE – Safety ‐ General Requirements; EN 60950‐1: ITE – Safety ‐ General Requirements; UL 60950‐1: ITE – Safety ‐ General Requirements; Low Voltage Directive 2014/35/EU
RoHS
Includes mains slide‐on adaptors for USA, Europe, and UK style connectors
Surge protection
Operating temperature
Storage temperature
Operating/Storage Humidity
Dimensions
Weight
EMC
Safety
Environmental
PS1921W‐10 Universal Power Supply Kit
100 ‐240 VAC to 15VDC supports multi‐geography AC voltage standards
90 to 264VRMS @ 45/66 Hz, 0.6A maximum
45/66 Hz
Three interchangeable adapters: NEMA 1‐15P (NP), CEE 7/16 and BS1363 (USA, EU, and JAPAN styles). USA adapter includes top‐center mounting lug to secure adapter to wall socket.
15 VDC nominal, ± 5%
1.5 A max, TA = ‐10° to +40°C (14° to 104°F); 0.6 A max, TA = ‐40° to +60°C (‐40° to 140°F)
F‐type Coax Connector, allows use of standard RF coax cable to R‐ONU
6 kV combination wave per IEEE/ANSI C62.41
‐10° to +40°C (14° to 104°F); ‐40° to +60°C (‐40° to 140°F) at 0.6A max current
‐40° to +85°C (‐40° to 185°F)
5 to 95% RH, non condensing
1.69" W x 3.35" H x 1.93" D (4.3 cm x 8.5 cm x 4.9 cm)
0.66 lb. (0.3 kg)
EN 55022: Radiated and Conducted Emission for ITE; EN 55024: Immunity for ITE; 2014/30/EC: Electromagnetic Compatibility (EMC) Directive; IEC 60950‐1: ITE – Safety ‐ General Requirements; EN 60950‐1: ITE – Safety ‐ General Requirements; UL 60950‐1: ITE – Safety ‐ General Requirements; Low Voltage Directive 2014/35/EU
RoHS
Rated input voltage
Operating input voltage
Operating frequency
AC input connectors
DC Output
DC output current
DC output connector
Surge protection
Operating temperature
Storage temperature
Operating/Storage Humidity
Dimensions
Weight
EMC
Safety
Environmental
Ask us about the complete Access Technologies Solutions portfolio:
Fiber‐Deep
DOCSIS® 3.1
Node Segmentation
RFoG‐RFPON ONU (R‐ONU)
HPON™/RFoG
FTTx
RFoG/RFPON R‐ONU Power Supplies
SPECIFICATIONS Characteristics
Specification
Uninterruptible Power Supplies (UPS)
PS1811U‐00
Please review the data sheet document # 87‐10933 for complete specifications
108–253 VAC
50/60 Hz
IEC C8
PS1811U‐00: IEC C8 to NEMA 5‐15
13.5 VDC nominal
6 W nom. (ONT load)
F‐type coaxial
8.75” W x 7.75” H x 3.0” D (22.2 cm x 19.7 cm x 7.6 cm)
1.3 lb. (0.59 kg); battery: 5.7 lb. (2.6 kg)
0° to +40°C (32° to 104°F)
–20° to +50°C (–4° to +122°F)
5% to 95% non–condensing
UL/CSA/EN 60950‐1
FCC Part 15 Class B, EN 55022, EN 55024
AC input voltage
Input frequency
AC Input connector
Power cord
Output voltage
Operational output power
Output connector
Dimensions
Weight
Operating temperature
Storage temperature
Humidity
Safety
EMC
CE, RoHS compliant
Model identification
UPS Battery (Sold separately)
Alpha FlexPoint FPR1207‐F
PS1801B‐00
12 VDC Standby Battery for PS1811U‐00 UPS
7.2 AH AGM battery
Provides approximately 10 hrs of backup at 6W (or 20 hrs at 3W) to 25% reserve point shut‐off, based on new, fully‐charged battery
Hot‐swappable
Recharge time 18 hours to 90%
Uses maintenance‐free sealed‐lead acid
Battery storage
–20° to +40°C (–4° to 104°F), six months maximum storage duration at +25°C (+77°F) without a recharge
RELATED PRODUCTS
R‐ONU CPEs
RFoG and RFPON CPE modules OBI‐free R‐ONUs
OR4148H and OR4168H Diplexer/Receivers
Note: Specifications are subject to change without notice.
Copyright Statement: ©ARRIS Enterprises, LLC, 2016. All rights reserved. No part of this publication may be Customer Care
reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from ARRIS Enterprises, LLC (“ARRIS”). ARRIS Contact Customer Care for product information and sales:
• United States: 866‐36‐ARRIS
• International: +1‐678‐473‐5656
reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of ARRIS to provide notification of such revision or change. ARRIS and the ARRIS logo are registered trademarks of ARRIS Enterprises, LLC. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks or the names of their products. ARRIS disclaims proprietary interest in the marks and names of others. The capabilities, system requirements and/or compatibility with third‐party products described herein are subject to change without notice.
87‐10592_RevE_RFoG‐and‐RFPON‐Powering‐Solutions
Ask us about the complete Access Technologies Solutions portfolio:
Fiber‐Deep
DOCSIS® 3.1
Node Segmentation
09/2016 ECO‐10842
RFoG‐RFPON ONU (R‐ONU)
HPON™/RFoG
FTTx