Accessory 4010-0010 40W Single Output Industrial DIN Rail Power Supply l Universal AC input / full range l Protections: Short circuit, over voltage, overload l Can be installed on DIN rail TS-35/7.5 or 15 l Cooling by free air convection l LED indicator for power on l 100% full load burn-in test l Two year warranty Specifications Output Environment DC Voltage 24V Working Temp. -20 - +70°C (Refer to output load derating curve) Rated Current 1.7A Working Humidity 20 ~ 90% RH non-condensing Current Range 0 ~ 1.7A Storage Temp., Humidity -40 ~ +85°C, 10 ~95% RH Rated Power 40.8W Temp. Coefficient ±0.03%/°C (0 ~50°C) Ripple & Noise (max.) 150mVp-p Vibration Voltage Adj. Range 24 ~ 30V 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Voltage Tolerance ±1.0% Line Regulation ±1.0% Load Regulation ±1.0% Safety Standards UL508, UL60950-1, TUV EN60950-1 approved Setup, Rise Time 500ms, 30ms/230VAC/115VAC at full load Withstand Voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC Hold Time 50ms/230VAC 20ms/115VAC at full load Isolation Resistance Certifications Safety & EMC Input Voltage Range 85 ~ 264VAC Frequency Range 47 ~ 63Hz Efficiency (Typ.) 88% AC Current (Typ.) 1.1A/115VAC Inrush Current (Typ.) COLD START 30A/115VAC 60A/230VAC Leakage Current <1mA / 240VAC 120 ~ 370VDC 0.7A/230VAC EMC Emission EMC Immunity Others MTBF 301.7K hrs min. MIL-HDBK-217F (25°C) Dimension 40*90*100mm (W*H*D) Packing 0.33Kg; 42pcs/14.8kg/0.82CUFT Protection Overload Over Voltage DS-4010-0010, Rev. 00 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 31.2V ~ 36V Protection type : Shut down o/p voltage, re-power on to recover I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC 25°C / 70%RH Compliant to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 Compliant to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industy level, criteria A Order Part Number Printed in USA 4010-0010 November 2013 M D R - 6 0 series Dimensions 40 100 40 5 5 5 5 5 5 5 5 5 5 +V +V -V -V 35 40 +V +V -V -V + 100 5 5 5 5 5 + +V ADJ 90 +V ADJ +V +V -V -V L +V ADJ + N 7.5 7.5 N L 90 90 100 N 7.5 7.5 Block Diagram EMI FILTER I/P L 7.5 7.5 RECTIFIERS & FILTER RECTIFIERS & FILTER POWER SWITCHING +V -V O.C.P. DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. 100 12V,24V,48V 80 100 90 80 70 60 50 5V 40 60 50 20 -20 40 0 Maple Systems, Inc. 10 20 30 45 55 134th 60 St SW, 70 (VERTICAL) 808 Suite 120, Everett, WA 85 98204 95 100 115 120 140 160 180 425.745.3229 • 425.745.3429 (fax) • Email: maple@maplesystems.com • www.maplesystems.com 200 220 240 264