www.milwaukeeinst.com MW10 (Free Chlorine) Range Resolution Accuracy Typical EMC Dev. Light Source Light Detector Method Environment Battery Type Auto-Shut off Dimensions Weight MW11 (Total Chlorine) 0.00 to 2.50 ppm 0.01 ppm ±0.03 ppm ±3% of reading @ 25 °C ±0.01 ppm Light Emitting Diode @ 525 nm Silicon Photocell Adaptation of USEPA method 330.5. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample. 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing 1 x 1.5V AAA After 2 minutes of non-use 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) 64 g (2.25 oz.) 0.00 to 3.50 ppm 0.01 ppm ±0.03 ppm ±3% of reading @ 25 °C ±0.01 ppm Light Emitting Diode @ 525 nm Silicon Photocell Adaptation of USEPA method 330.5. The reaction between total chlorine and the DPD reagent causes a pink tint in the sample. 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing 1 x 1.5V AAA After 2 minutes of non-use 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) 64 g (2.25 oz.) MW12 ( Phosphate Range Resolution Accuracy Typical EMC Dev. Light Source Light Detector Method Range Resolution Accuracy Typical EMC Dev. Light Source Light Detector Method Environment Battery Type Auto-Shut off Dimensions / Weight The meter automatically turns off after 2 minutes in order to save the battery. They work exactly the same way as the other Milwaukee photometers: When specific reagents are added, the water sample takes on a degree of coloration that is proportional to the concentration of the parameter being measured. The photometer measures this coloration. When a light beam passes through the colored sample, energy with a specific wavelength is absorbed by the test substance. The photometer determines the coloration of the sample by measuring the transmission or absorption of light of this wavelength Printed in Hungary Authorized Distributor tester) Environment Battery Type Auto-Shut off Dimensions / Weight 0.00 to 2.50 ppm 0.01 ppm ±0.04 ppm ±4% of reading @ 25 °C ±0.01 ppm Light Emitting Diode @ 525 nm Silicon Photocell Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method. The reaction between phosphate and the reagent causes a blue tint in the sample. 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing 1 x 1.5V AAA After 3 minutes of non-use and 2 minutes after reading 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) 64 g (2.25 oz.) MW13 ( Iodine tester) The revolutionary new range of Milwaukee handy photometers are compact and easy to use, have a modern design, and measure Free Chlorine (MW10); Total Chlorine (MW11); Phosphate (MW12); Iodine (MW13) and Iron (MW14). Their main advantages are the small size, and the real simplicity when doing measurements on the spot. Within a few minutes you can get the required result on the LCD and the instrument directly displays the concentration of the specific component in ppm. 0.0 to 12.5 ppm 0.1 ppm ±0.1 ppm ±5% of reading @ 25 °C ±0.1 ppm Light Emitting Diode @ 525 nm Silicon Photocell Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. The reaction between iodine and the reagent causes a pink tint in the sample. 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing 1 x 1.5V AAA After 3 minutes of non-use and 2 minutes after reading 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) 64 g (2.25 oz.) MW14 ( Iron Range Resolution Accuracy Typical EMC Dev. Light Source Light Detector Method Environment Battery Type Auto-Shut off Dimensions / Weight The pho-tometer then uses a microproces- sor to calculate the concentration and displays the result. The field of application is really wide including agriculture, drinking water analyses, aquariums, swimming pools or fish farms. As a result of this versatility and the affordable price it is undoubtedly worth using these products. tester) 0.00 to 5.00 ppm 0.01 ppm ±0.04 ppm ±2% of reading @ 25 °C ±0.01 ppm Light Emitting Diode @ 525 nm Silicon Photocell Adaptation of the EPA Phenantroline method 315B, for natural and treated waters. The reaction between iron and reagent causes an oran ge tint in the sample. 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing 1 x 1.5V AAA After 3 minutes of non-use and 2 minutes after reading 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) 64 g (2.25 oz.) Milwaukee Electronics Kft. Alsókikötõ sor 11. 6726, Szeged, Hungary tel.: +36 62 428 050 fax: +36 62 428 051 e-mail: info@milwaukeeinst.com www.milwaukeeinst.com