Handy Photometers

advertisement
www.milwaukeeinst.com
MW10 (Free Chlorine)
Range
Resolution
Accuracy
Typical EMC Dev.
Light Source
Light Detector
Method
Environment
Battery Type
Auto-Shut off
Dimensions
Weight
MW11 (Total Chlorine)
0.00 to 2.50 ppm
0.01 ppm
±0.03 ppm ±3% of reading @ 25 °C
±0.01 ppm
Light Emitting Diode @ 525 nm
Silicon Photocell
Adaptation of USEPA method 330.5. The
reaction between free chlorine and the
DPD reagent causes a pink tint in the
sample.
0 to 50°C (32 to 122 °F)
max. 95% RH non-condensing
1 x 1.5V AAA
After 2 minutes of non-use
81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
64 g (2.25 oz.)
0.00 to 3.50 ppm
0.01 ppm
±0.03 ppm ±3% of reading @ 25 °C
±0.01 ppm
Light Emitting Diode @ 525 nm
Silicon Photocell
Adaptation of USEPA method 330.5.
The reaction between total chlorine
and the DPD reagent causes a pink
tint in the sample.
0 to 50°C (32 to 122 °F)
max. 95% RH non-condensing
1 x 1.5V AAA
After 2 minutes of non-use
81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
64 g (2.25 oz.)
MW12 ( Phosphate
Range
Resolution
Accuracy
Typical EMC Dev.
Light Source
Light Detector
Method
Range
Resolution
Accuracy
Typical EMC Dev.
Light Source
Light Detector
Method
Environment
Battery Type
Auto-Shut off
Dimensions / Weight
The meter automatically turns off after 2
minutes in order to save the battery. They
work exactly the same way as the other
Milwaukee photometers:
When specific reagents are added, the
water sample takes on a degree of coloration that is proportional to the concentration of the parameter being measured.
The photometer measures this coloration. When a light beam passes
through the colored sample, energy with
a specific wavelength is absorbed by the
test substance.
The photometer determines the coloration of the sample by measuring the
transmission or absorption of light of this
wavelength
Printed in Hungary
Authorized Distributor
tester)
Environment
Battery Type
Auto-Shut off
Dimensions / Weight
0.00 to 2.50 ppm
0.01 ppm
±0.04 ppm ±4% of reading @ 25 °C
±0.01 ppm
Light Emitting Diode @ 525 nm
Silicon Photocell
Adaptation of the Standard Methods for the Examination of Water and
Wastewater, 20th edition, Ascorbic Acid method. The reaction between
phosphate and the reagent causes a blue tint in the sample.
0 to 50°C (32 to 122 °F) max. 95% RH non-condensing
1 x 1.5V AAA
After 3 minutes of non-use and 2 minutes after reading
81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
64 g (2.25 oz.)
MW13 ( Iodine
tester)
The revolutionary new range of
Milwaukee handy photometers are
compact and easy to use, have a
modern design, and measure Free
Chlorine (MW10); Total Chlorine
(MW11);
Phosphate
(MW12);
Iodine (MW13) and Iron (MW14).
Their main advantages are the small
size, and the real simplicity when
doing measurements on the spot.
Within a few minutes you can get the
required result on the LCD and the
instrument directly displays the concentration of the specific component
in ppm.
0.0 to 12.5 ppm
0.1 ppm
±0.1 ppm ±5% of reading @ 25 °C
±0.1 ppm
Light Emitting Diode @ 525 nm
Silicon Photocell
Adaptation of the Standard Methods for the Examination of Water and
Wastewater, 18th edition, DPD method. The reaction between iodine
and the reagent causes a pink tint in the sample.
0 to 50°C (32 to 122 °F) max. 95% RH non-condensing
1 x 1.5V AAA
After 3 minutes of non-use and 2 minutes after reading
81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
64 g (2.25 oz.)
MW14 ( Iron
Range
Resolution
Accuracy
Typical EMC Dev.
Light Source
Light Detector
Method
Environment
Battery Type
Auto-Shut off
Dimensions / Weight
The pho-tometer then uses a microproces-
sor to calculate the concentration and displays the result.
The field of application is really wide
including agriculture, drinking water analyses, aquariums, swimming pools or fish
farms. As a result of this versatility and the
affordable price it is undoubtedly worth
using these products.
tester)
0.00 to 5.00 ppm
0.01 ppm
±0.04 ppm ±2% of reading @ 25 °C
±0.01 ppm
Light Emitting Diode @ 525 nm
Silicon Photocell
Adaptation of the EPA Phenantroline method 315B, for natural and
treated waters. The reaction between iron and reagent causes an oran
ge tint in the sample.
0 to 50°C (32 to 122 °F) max. 95% RH non-condensing
1 x 1.5V AAA
After 3 minutes of non-use and 2 minutes after reading
81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
64 g (2.25 oz.)
Milwaukee Electronics Kft.
Alsókikötõ sor 11.
6726, Szeged, Hungary
tel.: +36 62 428 050
fax: +36 62 428 051
e-mail: info@milwaukeeinst.com
www.milwaukeeinst.com