3. User's Manual 751574 Current Transducer Insert the primary conductor into the primary conductor feed-through hole on the device. Make sure that the direction of current flow matches the arrow on the device. Correct Incorrect Conductor Using an earth-shielded conductor Direction of current Using two parallel conductors Current flows in both directions Primary current Thank you for purchasing the Current Transducer (Model 751574). In order to take advantage of all the functions of the transducer and to ensure proper use, please read this user’s manual thoroughly before beginning operation. This device is a current sensor with a 1500:1 current transformation ratio that performs transformation on the primary current. After familiarizing yourself with the performance and functions of this device, you will be able to use it in conjunction with measuring instruments from Yokogawa Electric. Figure 3. Insertion of a Conductor 4. 5. Apply the primary current. Read the measured values. The following calculation is used to determine the current flowing through the primary conductor. Example: Given a current of 100 mA being output from pin 6 of the device’s secondary connector, 100 mA x 1500 = 150 A. Note • Never apply a current exceeding the allowable input range to the current input terminal of the instrument. A current equivalent to the primary rated current may flow from the output terminal even when the applied current is stopped. In that case, turn the power switch OFF and then back ON again. Then, the instrument may return to normal once a current of the allowable input range is applied. If it does not, contact your dealer or nearest YOKOGAWA representative. • Configure your setup so that the load resistance of the measuring instrument connected to the secondary signal output is 2.5 Ω or greater. • When measuring phase difference in voltage and current using an instrument such as a digital power meter, make sure that the current flows in the same direction as the arrows on that instrument. • Avoid locations with extremely strong external magnetic fields as they may cause measurement errors. Disk No. BA13 1st Edition : September 2001 (YK) All Rights Reserved, Copyright © 2001, Yokogawa Electric Corporation IM 751574-01E 1st Edition 1. Safety Precautions The following safety markings are used in this manual. CAUTION Note 4. Specifications Current Rating DC: 0 to 600 A AC: 600 Apeak Output Current Primary rated current at 600 A is 400 mA. Current Transformation Ratio 1500:1 Direction of Current Per the arrows printed on the main unit. Accuracy DC ±(0.05% of reading+40 µA) 50/60 Hz ±(0.05% of reading+40 µA) sine wave Standard Conditions 23±5°C 30 to 70%RH Primary current 2 A to 600 A Power supply voltage DC±(15 V ± 0.75 V) Common mode voltage 0 V Conductor φ25 mm; length, 300 mm or more; straight Within 3 months after calibration Accuracy 12 Mo. after Calibration Add the error in the reading value (reading) x 0.5 to the above accuracies. Effect of Position of Conductor Add ±(0.05% of reading) Measurement Band DC to 100 kHz (-3dB) Temperature Coefficient In the 10 to 18°C, 28 to 50°C ranges: 0.01%/°C Max. Allowable Continuous Input 600 Apeak Deleting of Max. Allowable Input Limited as shown in figure 4 when the primary current frequency exceeds 400 Hz. However, these are merely reference values. Instantaneous Max. Allowable Input 3000 Apeak 0.1 sec. or less (reference value) Load Resistance 2.5 Ω or more (see figure 5) Operating Temperature 10 to 50°C Operating Humidity 20 to 80%RH (no condensation) Storage Temperature 0 to 60°C External Dimensions Approx. 122(W) x 98(H) x 57(D) mm (excluding the connector and conductor guide) Diameter of Primary Current Hole φ26 mm Secondary Connector D-Sub 9 pin Weight Approx. 1 kg. Emission Conforms to EN61326 standards Immunity Conforms to EN61326 standards Power Supply Voltage ±(15 V ± 5%) Power Consumption Approx. 5 VA (when the secondary output current is 0) Current Consumption Approx. (330 mA + output current) Max. Tightening Torque for the Attachment Screw 0.2 kgm Accessories User’s manual: 1 pc. Opt. Accessories (Sold Separately) • D-Sub 9 pin connector (plug, part number B8200JQ): 1 pc. • Load resistor (2.5 Ω, part number B8200JR, accuracy of resistance value ±0.1%, temp. coefficient 22 ppm/°C): 1 group of 4 10-Ω resistors connected in parallel yielding 2.5 Ω WARNING • Beware of electric shock. Do not perform measurement if the case is damaged. Do not operate the device with wet hands, in a rainy or humid environment, or if any water droplets are visible on it. Condensation may appear if sudden changes in temperature occur. If this happens, let the device acclimatize to the new temperatures for at least one hour, then refrain from using the device until confirming that there is no condensation. • Do not disassemble the device. The device should be disassembled by qualified personnel only. • Use the correct power supply. Ensure that the source voltage matches the voltage of the power supply before turning ON the power. • Do not use with non-insulated conductors or cables*. Use conductors or cables with reinforced insulation. • Although it is well-insulated, do not touch the device or secondary output cable when voltage is being applied to the primary conductor. • Connect the secondary signal output before supplying power to the device. • Do not disconnect the secondary output while power is being supplied to the device. • Do not apply primary current before supplying power to the device. • Do not input excessive current as malfunction or damage may result. • Do not allow vibrations to disturb the device after it has been set in place as damage may result. * An insulation system having the same level of shock protection as double insulation. Consult with your cables’ manufacturer for details. 2. Names of Parts Reverse Primary conductor feed-through hole Secondary connector signal allocation Attachment screw holes (M6 x 10) Conductor guide 1 Secondary connector 5 Pin No. 1 to 3 4 5 6 7,8 9 Signal [Do not connect] 0 V power supply input –15 V power supply input Secondary signal output [Do not connect] +15 V power supply input Pin assignment 6 9 Figure 1. Names of Parts and Pin Assignments 1000 Maximum Allowable Input Current [Arms] Front Load Resistor [Ω] WARNING Danger. Refer to the corresponding location on the device. This symbol appears on dangerous locations on the device which require special instructions for proper handling or use. The same symbol appears in the corresponding place in the manual to identify those instructions. Calls attention to actions or conditions that could cause serious injury or death to the user, and precautions that can be taken to prevent such occurrences. Calls attention to actions or conditions that could cause damage to the instrument or user’s data, and precautions that can be taken to prevent such occurrences. Calls attention to information that is important for proper operation of the instrument. 100 10 1 3. Operation 10 100 1000 10000 100000 Frequency [Hz] Figure 4. Deleting of Primary Current by Frequency CAUTION 100 90 80 70 60 50 40 30 20 10 0 0 50 100 200 300 400 500 600 150 250 350 450 550 Primary Current [A] Figure 5. Deleting of Primary Current by Load Resistance CURRENT Ensure that the current flowing to the conductor of the object to be measured is within the measuring range. If the current exceeds the measuring range, the device may overheat and become damaged. 122 73 M6 x 10 (2) 25 Operating Procedure 1. Connect the secondary connector on the device to the current input terminal on the measuring instrument, and connect to 0 V (common) and ±15 V on the power supply. 2. Set up the measuring instrument and power supply to match the specifications of the current transducer. Carefully read the user’s manuals for your measuring instrument and power supply to obtain the correct procedure for making the connections. 62 98 23.5 57 65 Measuring instrument Secondary connector 6 φ28.1 φ26hole Rb Rb: Load resistor* Unit : mm Current input terminal Figure 6. External Dimensions 5. Servicing Power supply 4 5 9 0 V(common) –15 V +15 V * Set so that the measuring instrument's internal resistance plus the load resistance (Rb) is 2.5 Ω or greater. If you encounter any problems during use, or if the device does not appear to be operating normally, contact Yokogawa Electric Engineering services or the dealer from whom you purchased it. 6. Warranty If you experience a breakdown in the device due to faulty manufacturing or accidents during shipping, contact Yokogawa Electric Engineering Services or the dealer from whom you purchased the device. Figure 2. Connection Example IM 751574-01E 1st Edition