1 OF 4
Installation Instructions
4” Gravity Enhanced Color Cylinder - Surface Mount
! WARNING
Risk of electrical shock. Disconnect power
before servicing or installing luminaire.
! WARNING
Risk of injury or damage. Luminaire will
fail if not installed properly. Follow
installation instructions.
IS-C1025R2
IMPORTANT SAFETY INSTRUCTIONS
–– Read all installation instructions before installing. It is important to save these instructions.
–– Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with
power on, could damage the LEDs and is not covered by warranty.
–– Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module,
warnings of installation near combustible materials and/or insulation.
–– Be sure to connect ground wire to prevent electric shock or other potential hazards.
–– The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local
codes by a person familiar with the construction and operation of the product and the hazards involved.
–– WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a
violation of N.E.C 110-3(B) and voids all warranties.
! WARNING
Risk of injury. Wear safety glasses and
gloves during installation and servicing.
Allow ample time to cool before handling.
1
ATTACH MOUNTING BRACKET TO JUNCTION BOX:
1. Attach the mounting bracket to junction box using hardware supplied with junction box.
2
ELECTRICAL CONNECTIONS:
1. Attach the safety cable from the cylinder to split ring on the mounting bracket.
2. Make electrical connections through center hole of the mounting bracket.
3. Connect ground wire from universal mounting bracket to green (ground) supply wire and
ground wire from fixture, white wire from cylinder to white (neutral) supply wire and
black wire from cylinder to black (hot) supply wire. Use UL listed connectors or wire nuts
(by others) to make the connections. Connect dimming wires if applicable, see page 4.
Additonal
mounting
holes
Ground wire
Safety cable
Split ring
3
MOUNTING CYLINDER TO MOUNTING BRACKET:
1. Pull out the locking tab on the cylinder’s top plate.
2. Align the keyholes on the cylinder’s top plate with the spring standoffs.
3. Lift the cylinder into the spring standoffs and rotate the cylinder clockwise.
4. Make sure the gap between the ceiling and cylinder is even to ensure the fixture is installed correctly. Push
Even gap
Spring standoffs
Locking tab
Keyholes
INSTRUCTIONS L/M-08032016 P-11
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
2 OF 4
IS-C1025R2
LOCKING CYLINDER:
1. Push in the locking tab to lock the cylinder into the spring standoff bracket.
4
Locking tab
MAINTENANCE:
1. Pull out the locking tab on the cylinder’s top plate. Lift up and rotate the cylinder counter clockwise to release it from the mounting bracket.
2. Disconnect wires from junction box and disconnect the safety cable from split ring if applicable.
3. Remove all three M3 x 10mm flat head fasteners and lid.
4. Remove two 8-32 nuts from the driver and keep for replacement.
5. Replace new driver on driver plate, see wiring diagram on page 3.
M3 x 10mm flat head
Pull out locking tab
Driver holder
Split ring
Safety cable
8-32 nuts
INSTRUCTIONS L/M-08032016 P-12
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
3 OF 4
0-10V Dimming and Tuning Control Functions
Tunable White only
Wiring Diagram
Compatible Control Systems
Dimmer By Others
CCT
Dimming
For 0-10V Continuous CCT Control. Connect a 0-10V
control device to the blue (+) and white
(ground) wires. When the fixture is powered up, the
0-10V control will adjust the CCT over the tunable
range.
Tunable White & Dynamic Dimming
A 0-10V control may also be added for dimming
(as shown). Adjustments to Dimming levels are a
percentage of the 0-10V Dim setting (Trim). If a 0-10V
control is not used for dimming, the gray (ground) and
violet (+) wires must be grounded together.
Blue (TW only)
White (TW only)
LED
Grey
Luminaire
Violet
LED
Luminaire
Hot (Black)
Neutral (White)
Ground (Green)
Brand
Model
LevitonIP710-DLX
LevitonIP710-LFZ
LevitonSapphire
LevitonOmnitouch
Lutron
Diva, DVTV
Lutron
Nova-T, NTFTV
Lutron
Diva, NFTV
Lutron
Grafik Eye -GRX-TVI with GRX3503
Lutron
Energi Savr Node - QSN-4T16-S
Lutron
TVM2 Module
LightolierV2000FAMU
LightolierZP600FAM120
LightolierMP1500FAM120
Watt Stopper
DCLV1
TW = Tunable White - Example: MXDRTRTW1
DMX RDM Dimming and Tuning Control Functions
Standard default is Ch 1 dimming and Ch 2 CCT Control for Tunable White.
Standard default is Ch 1 for Dynamic Warm Dimming
DMX Control Options
1. Warm dim mode: In this mode, the luminaire warms
as it dims. It uses only one DMX-channel.
2. CCT tuning mode: In this mode, luminaire’s CCT
tunes along the black body curve. It uses two
DMX-channels, one for Brightness control and one
for CCT tuning
Compatible Control Systems
Wiring Diagram
LED
Luminaire
LED
Luminaire
Hot (Black)
Neutral (White)
Ground (Green)
Brand
Model
AcuityFresco
DMXister
DMXister test suite
NXP
NXP RDM SDK
Pathway Connect
Pathport
Open Lighting Project
RDM test suite
Ground (Brown/White)
Data DMX + (Orange/White)
Data DMX - (Orange)
DALI Dimming and Tuning Control Functions
DALI Control Functions
The luminaire can be operating in two different modes:
- Dynamic warm dimming mode, DALI device type 6
(DT6) compatible (Control gear 102)
- CCT tuning mode, DALI device type 8 (DT8) compatible
(Control gear: 209 Color control)
By default the unit will start up in warm dimming
mode with base address 0, but when it receives a DT8
command (dim warm/cool) it will switch to the CCT
tuning mode. It cannot switch automatically back.
Only a special DALI command (SetTcPHY_coolest=0) or
resetting the ARD function will set it back to the warm
dimming mode. This should not be done dynamically
as there are only a limited amount of resets possible
(10,000).
Wiring Diagram
Compatible Control Systems
LED
Luminaire
Hot (Black)
Neutral (White)
Ground (Green)
DALI DA (Orange)
DALI DA (Orange/White)
INSTRUCTIONS L/M-08032016 P-13
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
LED
Luminaire
Brand
Leviton
Hadler
Lunatone
Model
DALI Controller CD250-C
DALI uP
DALI Switch 86459793
4 OF 4
INTENSE LIGHTING WARRANTY
INTERIOR LED PRODUCTS: 5-YEAR LIMITED WARRANTY
Intense Lighting warrants the LED electronics and components of its properly installed EXTERIOR LED products listed
below, to be free of defects in material and workmanship in normal use, for a period of five years from the date of our
shipment and warrants the painted finish for a period of one year from the date of our shipment.
Intense Lighting will repair or replace, at its option, any warranted product returned to it that it determines to be
defective. This limited warranty does not include installation or removal. In addition to complete failure, defects include
lumen depreciation to levels below 70% of initial lumen output within warranty period and/or color shift beyond that
which is set forth in the Energy Star Program Requirements for SSL – Version 1.1 within warranty period. The painted
finish of the product will be considered defective in material or worksmanship only if there is substantial deterioration in
the form of blistering, cracking, or peeling.
Defects do not include improper installation or operation, alterations, power surges or overheating due to external
conditions. The painted finish is not warranted against fading or chalking, as it may naturally flake or chalk over time
due to normal aging. To receive credit for defective merchandise, product must undergo quality inspection prior to the
processing of credit. If the product is found defective, you will be issued a credit. Product in good working condition will
not receive a credit. Please inform your accounting department to not short pay or issue any debits to our company
regarding a return. Testing and evaluation can take approximately 1-2 weeks based on quantity. At that time you will be
notified if credit is granted for your warranty return.
THE ABOVE EXPRESS WARRANTY STATES THE FULL AND COMPLETE OBLIGATION OF INTENSE LIGHTING. ALL IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE
TERM OF THE EXPRESS WARRANTY. UNDER NO CIRCUMSTANCES WILL INTENSE LIGHTING ACCEPT LIABILITY FOR ANY
CONSEQUENTIAL SPECIAL OR INDIRECT DAMAGES WHETHER ARISING OUT OF CONTRACT, TORT, OR STRICT LIABILITY.
INSTRUCTIONS L/M-08032016 P-14
Intense Lighting
3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883
©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.