Type Catalog Number FEATURES • Die-formed turret housings enclose telescoping, pressure lock lampholders. • Available in tandem-wired lengths. • 2-lamp models feature 6" lamp spacing for superior efficiency, 3-lamp models have 3" spacing. • Premium gauge die-formed channel features gripper back design for strength and rigidity. • Sturdy channel cover secured by quarter-turn latch for easy access to wireway. • High-gloss, baked white enamel finish. • Accepts plug-in options for 1, 2 or 3 primary circuits. • For unit or row installations, surface or suspended mounting. Channel connectors furnished standard. Catalog number Type ...................................... ...................................................................................................................................................... ...................................... ...................................................................................................................................................... ...................................... ...................................................................................................................................................... Heavy-Duty Turret Strip SL Rapid Start 2', 3' or 4' length 1, 2, 3 or 4 lamps SPECIFICATIONS BALLAST — Thermally protected, resetting, Class P, HPF, non-PCB, UL listed, CSA certified ballast is standard. Rapid start ballasts are sound rated A. Standard combinations are CBM approved and conform to UL 935. WIRING & ELECTRICAL — Fixture conforms to UL 1570 and is suitable for wet locations. AWM, TFN or THHN wire used throughout, rated for required temperatures. MATERIALS — Housing formed from cold-rolled steel. No asbestos is used in this product. FINISH — Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted parts finished with high-gloss, baked white enamel. LISTING — UL listed and labeled. CSA certified (see options). NOM labeled (see options). ENERGY • Luminaire Efficiency Rating (LER) Two lamp LER.FS = 64. Based on 34W T12, 2650 lumen lamp and energy-saving magnetic ballast with ballast factor = .87 and input watts = 71. Calculated in accordance with NEMA standard LE-5. See LER sheet for details. Specifications subject to change without notice. PHOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%. Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request. SL 240 Report ITL 21461 S/MH 1.4 Coefficient of Utilization Ceiling 80% Wall 70% 50% 30% 1 2 3 4 5 10 97 87 79 72 66 44 92 79 69 60 53 31 87 72 60 52 44 23 SL 2 32 120 Report L5714 S/MH 1.4 Coefficient of Utilization 70% 70% 50% 30% 50% 50% 30% 10% 91 82 74 67 61 41 76 65 57 50 44 26 86 74 65 57 50 29 82 66 57 49 42 22 Zonal Lumens Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp 816 1373 2608 4116 2161 6276 12.8 21.5 40.7 64.3 33.8 98.1 73 60 51 44 37 20 70 56 46 39 32 16 Ceiling 80% 70% 50% Wall 70% 50% 30% 70% 50% 30% 50% 30% 10% 1 2 3 4 5 10 94 85 77 70 63 42 88 79 71 65 59 39 73 62 54 48 42 25 89 76 66 58 51 30 84 69 58 49 42 22 83 71 62 54 48 28 79 65 55 47 40 21 70 57 48 41 35 19 67 53 44 36 30 15 Zonal Lumens Summary %Fixture Zone 13.0 21.9 41.6 65.6 34.4 100.0 0-30 0-40 0-60 0-90 90-180 0-180 Lumens %Lamp 672 1123 2159 3568 1991 5560 COMMERCIAL & INDUSTRIAL FLUORESCENT LIGHTING 11.6 19.4 37.2 61.5 34.3 95.9 %Fixture 12.1 20.2 38.8 64.2 35.8 100.0 SL RS SL Rapid Start MOUNTING DATA DIMENSIONS For unit or row installation, surface or suspended mounting. Inches (centimeters). Subject to change without notice. Unit installation — Minimum of two hangers required. Row installation — One hanger per channel plus one per row required. Hooker® (HRUN) and HC Hangers – Minimum two per channel (unit and row) for 5" channels only. See ACCESSORIES below for hanging devices. A= 1/4” x 1/2” hole C= 7/8” dia. K.O. D= 11/16” dia. K.O. E= 2” dia. K.O. F= 7/16" dia. K.O. 5 (12.7) A D A C D E A D D C 1-5/8 (4.13) 3 (7.62) 6 (15.24) D A 1-1/4 (3.18) 3-1/4 (8.26) 48 (121.9) 4-1/4 (10.8) 4-1/4 (10.8) 99-19/32 (253) Example: SL 2 40 120 ES GLR ORDERING INFORMATION Series Number of lamps SL Heavy-duty turret strip 1, 2, 3, 4 For tandem doublelength unit, add prefix T. Example: TSL Not included Lamp type 17 20 25 30 32 40 17W T8 (24") 20W TS T12 HPF (24") 25W T8 (24") 30W RS T12 HPF (24") 32W T8 (48") 40W T12 (48") Accessories Order as separate catalog numbers. SQ_ 1B DSH24 HC36 THUN HRUN HRUN1 Swivel-stem hanger. Ceiling spacer (adjusts from 1-1/2" to 2-1/2" from ceiling). Double-stem hanger for 4' fixtures, 24" stems. Chain hangers (1 pair, 36" long). Tong hanger for 5" channel. ® Hooker T-bar hanger for 5" channel (flush to ceiling). Hooker® T-bar hanger for 5" channel (1-1/2" from ceiling). Options Voltage 120, 277, 347 Others available ES GEB GEB10 EL LPF GLR GMF CS1 CS7 CS3 CS11 PLF_ TILW CSA NOM SW HC36 Energy-saving ballasts (30W and 40W only). Electronic ballasts, <20% THD. Electronic ballasts, <10% THD. Emergency battery pack (nominal 300 lumens). See Life Safety Section. Low power factor ballasts (20W and 30W only). Internal fast-blow fuse (add X for external). Internal slow-blow fuse (add X for external). 6' cordset, NEMA 5-15P SJT, U-ground plug, 120V. 6' cordset, NEMA 5-15P SJT, U-ground plug, 277V. 6' cordset, NEMA L5-15P SJT, twist-lock plug, 120V. 6' cordset, NEMA L5-15P SJT, twist-lock plug, 277V. Plug-in wiring. Specify 1, 2 or 3 branch circuits and hot wires (A=Black, B=Red, C=Blue, AB or AC). Tandem in-line wiring. CSA-labeled for US shipment to Canada. NOM-labeled for shipment to Mexico. Palletized and stretch-wrapped. Chain hanger set packed in channel. SL RS ©1996 Lithonia Lighting, Rev. 5/96 SLRS.pm5 COMMERCIAL & INDUSTRIAL FLUORESCENT LIGHTING P.O. BOX A, CONYERS, GEORGIA 30207-0067, TELEPHONE 770 922-9000, FAX 770 860-3106