37420 GE Consumer & Industrial Power Protection GE Consumer & Industrial The Power Protection division (formerly GE Power Controls) of GE Consumer & Industrial is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panel-board builders, contractors, OEMs and utilities worldwide GE Consumer & Industrial Power Protection www.ge.com/eu/powerprotection www.gepowercontrols.com M-PACT Plus - Air Circuit Breakers ED.02 GE POWER CONTROLS International Sales Nieuwevaart 51 B-9000 Gent - Belgium Tel. +32/9 265 21 11 Fax +32/9 265 28 90 E-mail: gepcbel@gepc.ge.com M-PACT Plus Air Circuit Breakers 400 - 6300A GE POWER CONTROLS Ltd Lincoln Road Enfield Middlesex EN1 1SB United Kingdom Tel. 0800 587 1251 Fax 0800 587 1239 E-mail: gepcuk@gepc.ge.com GE imagination at work GE imagination at work 680809 Ref. I/3197/E/EX 5.0 Ed. 04/06 © Copyright GE Power Controls 2006 ED.02 M-PACT Plus Technical overview A Order codes B Wiring diagrams / Dimensional drawings C Numerical index X Just rel M-PACT Plus A.3 Introduction A.4 A.6 A.8 Fixed pattern circuit breaker - frame 1, 2, 3 Withdrawable circuit breaker - frame 1, 2, 3 Characteristics A.11 A.12 A.13 A.16 A.18 A.19 A.20 M-PRO protection relays - Electronic trip units Range Curves & terminology M-PRO 17 Plus, M-PRO 18 Plus Current protection MCR making current release, reset mechanism, thermal memory, healthy LED, test connector and test box LCD display M-PRO 17 Plus, M-PRO 18 Plus, M-PRO 30/40 Specifications Other functions A.22 A.23 A.24 Trip curves M-PRO Plus - frame 1 & 2 M-PRO Plus - frame 3 M-PRO 30/40 - frame 1 & 2 A.26 A.28 Earth fault protection curves M-PRO 30/40 - frame 1 & 2 M-PRO 17 Plus/18 Plus - frame 1 & 2 A.29 A.34 A.36 Accessories Frame 1 & 2 Frame 3 Performance data all accessories Technical overview A Order codes B Wiring diagrams / Dimensional drawings C Numerical index X y on us A.1 M-PACT Plus Technical overview Notes A B C X A.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M-PACT Plus Introduction Specification M-PACT Plus air circuit breakers comply with the following specifications for low voltage switchgear: • IEC 947-1 • IEC 947-2 • IEC 947-3 • VDE 0660 Part 101 and Part 107 • Utilization category B Approvals LOVAG certification in accordance with IEC 947-2, BS EN 60947-2 ASTA, KEMA Introduction Rated from 400 to 6300A the M-PACT Plus circuit breaker has been designed to meet the most stringent demands in fault detection and safe interruption thereof. Available in 3 frame sizes: • Frame size 1 ranging from 400 to 2500A • Frame size 2 ranging from 800 to 4000A • Frame size 3 ranging from 5000 to 6300A The range has been developed aesthetically and technically to co-ordinate with other protective devices within our company for industrial/domestic applications. All 3 frame sizes have unique look available with both fixed pattern and drawout versions which can be manually or electrically operated. These ACBs are designed to offer multiple mains connection options it also comes with a wide range of easy-to-install accessories. A B C X ICU (kA) 100 90 80 Type C 70 60 Type H - Frame 3 50 40 Type N Frame 1 30 Frame 2 20 Type S 10 0 400 630 800 1000 3 compact frame sizes Frame size 1 - 400 to 2500A Frame size 2 - 800 to 4000A Frame size 3 - 5000 to 6300A • Frame 1 & 2 Fixed & withdrawable version is offered with 3 or 4 pole configuration, front and rear access connections (horizontal / vertical). • Frame 3 Fixed and withdrawable version is offered with 3 Pole only, rear connections (horizontal/vertical) • Devices provided with or without protection relay • Manual or electrical operation and built-in safety features e.g. safety shutters 1250 1600 2000 2500 3200 4000 5000 6300 Ith (A) • Wide range of protection settings offering full selectivity combinations of earth fault protection with simple & easy service on site 4 performance ranges(1) Type S : 50 kA Icu = Type N : 65 kA Icu = Type H : 80 kA Icu = Type C(2) : 100 kA Icu = Ics Ics Ics Ics = = = = Icw Icw Icw Icw (1) Ratings shown at 500V AC (2) Ratings shown at 690V AC A.3 M-PACT Plus Technical overview Fixed pattern circuit breaker Frame 1 & 2 All M-PACT Plus fixed pattern air circuit breakers incorporate a stored energy mechanism. The spring can be charged either manually or electrically via a motor operator that is automatically activated after the closing operation. IP43 front panel and door escutcheon seals are standard features with IP20 protected secondary isolating contacts. For enhanced protection, an optional IP54 door panel is also available. Installation Fixed pattern M-PACT Plus can be fastened into any suitable switchboard or cubicle arrangement using four M8 bolts. Clearance is only required above the unit for the removal and inspection of the arc chutes (see dimensional drawings for mounting details and recommended clearance distances). An earthing point is provided on either side of the circuit breaker. Power supply All stated short-circuit ratings are certified with incoming supply connection made to either upper or lower terminals. 3 3 4 5 6 8 2 7 9 A 10 B 1 11 C X 12 • • • • • • • • • • • • • • A.4 Trip-free operating mechanism Positive ’ON/OFF’ main contact indication Mechanical/electrical anti-pumping device Charging spring status indication Ergonomic manual spring charging handle Field-mountable range of accessories Auxiliary switches 5 NO and 3 NC, potential free 10A 250V (standard) Mechanical trip alarm switch (1 NO/NC) (optional) Padlockable push-button cover (for mechanical and electrical lock) Mechanical cable interlocking (optional) Termination: rear, horizontal or front access (optional) Electrical clearances according to IEC 947-2 Front access of secondary terminals for simple connection Maintainable arcing contacts are offered as a standard feature. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Motorised spring charging unit (optional) M-PRO protection relay (optional) Secondary contacts Shunt trip (optional) Closing coil (optional) Undervoltage release (optional) Manual charging handle ON/OFF push-buttons Push-button padlockable covers Positive contact indication Charging spring status indication Mounting plate M-PACT Plus Frame 3 Power supply M-PACT Plus frame 3 fixed pattern air circuit breakers incorporate a stored energy mechanism. The spring can be charged either manually or electrically via a motor operator that is automatically activated after the closing operation. incoming supply connection made to either upper or All stated short-circuit ratings are certified with lower terminals. 2 1 7 IP43 front panel and door escutcheon seals are standard features. 3 8 10 9 6 8 12 • • • • • • • • • • • • Trip-free operating mechanism Positive ’ON/OFF’ main contact indication Mechanical/electrical anti-pumping device Charging spring status indication Manual spring charging handle Auxiliary switches 4 NO and 6 NC, 10A 500V (standard) Mechanical trip alarm switch (1NO) (potential free) (standard) Padlockable push-button cover Mechanical cable interlocking (optional) Termination: horizontal Electrical spring charge indication Easy replacement of main and arcing contacts 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 11 Motorised spring charging unit (optional) M-PRO protection relay (optional) Secondary contacts Shunt trip (optional) Closing coil (optional)* Undervoltage release (optional) Manual charging handle ON/OFF push-buttons Push-button padlockable cover Positive contact indication Charging spring status indication Rear fixation point Fixed pattern 4 A B C * Feature not visible in picture. X Installation Fixed pattern M-PACT Plus frame 3 can be fastened into any suitable switchboard or cubicle arrangement using four M10 bolts (see dimensional drawings for mounting details and recommended clearance distances). An earthing point is provided on left side of the circuit breaker. A.5 M-PACT Plus Technical overview Withdrawable circuit breaker Frame 1 & 2 Pre-mounted into a self-contained ’cassette’, this versatile circuit breaker can be inserted or withdrawn via sliding rails using a racking drive mechanism controlled by a racking handle. It provides three set positions: Disconnected / Test / Connected. Any attempt to withdraw the unit whilst in service will automatically trip the breaker, either by the racking position safety mechanism or by the insertion of the racking handle. It can be racked to the disconnected position with the cubicle door closed or open. Installation Circuit breakers are delivered pre-mounted in the cassette (standard) Versatile fixing arrangements allow mounting onto any switchboard or cubicle using four M8 bolts (see dimensional drawings for mounting details and recommended clearance distances) Earthing point situated on the right hand side of cassette (front view) Power supply All stated short-circuit ratings are certified with incoming supply connection made to either upper or lower terminals. 4 3 A 2 B 1 5 10 C 9 8 7 6 X • • • • • • • • • • • A.6 Insulated shutters to isolate the main contact zone Front access padlocking for safety shutters Secure padlocking in the "Disconnect" position Clearly visible operational position indication Carriage position switch (optional) Termination: Flat copper palms (standard) with captive M10 fixing nuts Rear terminal adaptors for horizontal/vertical connection (optional) Front access connections (optional) Automatic disconnect of secondary circuits Lifting lugs for ease of removing the circuit breaker from the cassette (M-PACT Plus handling truck required) Front access of secondary terminals for simple connection 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Carriage position switch (optional) Slide rails Insulated safety shutter Secondary terminals 2 or 3 way interlock mechanism (optional) Racking handle (storage) Padlocking for safety shutters Insertion hole for racking handle Padlocking in the DISCONNECTED position Operational position indication Key interlock (optional)* * Feature not visible in picture M-PACT Plus Frame 3 5 2 1 8 11 3 4 Installation The carrier is designed to be fastened in the switchboard on horizontal mounting rails using eight M8 screws (see dimensional drawings for mounting details and recommended clearance distances). Power supply All stated short-circuit ratings are certified with incoming supply connection made to either upper or lower terminals. 9 Withdrawable version Pre-mounted into a self-contained ’cassette’, this versatile circuit breaker can be inserted or withdrawn via sliding rails using a racking drive mechanism controlled by a racking handle. It provides three set positions: Disconnected / test / connected Any attempt to withdraw the unit whilst in service will automatically trip the breaker (by the racking position safety mechanism) It can be racked to the disconnected position with the cubicle door closed or open. • Carriage position switch (optional) • Shutters and padlocking facility • Contact indication • Termination: 5000A rear horizontal or vertical / 6300A rear vertical • Automatic disconnect of secondary circuits • Easy wiring of the control circuit contacts • Carrying handles for easy of removing the circuit breaker from the cassette A 3 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Secondary contacts Carriage position switch (optional) Connection busbars Connection point cover Safety shutter 2 way cable interlock mechanism (optional)* Racking handle * Spindle mechanism Operational position indication Locating spring for door interlock* Sliding unit B C X * Features not visible in picture A.7 M-PACT Plus Characteristics Technical overview Performance data A B C Characteristics Symbol Units 400 A Rated current (40°C) In Endurance (n° of operating cycles) 20000 Mechanical (with maintenance) 10000 Mechanical (without maintenance) 5000 Electrical (at rated current) 690 V Rated service voltage (50/60 Hz) Ue 1000 V Rated insulation voltage Ui 8000 V Rated impulse withstand voltage Uimp 3&4 Number of poles 100% Rating of 4th pole ACB type S N Frame size 1 1 kA (rms) Rated ultimate short-circuit Icu Breaking capacity 220V 50 65 415V 50 65 500V 50 65 600V 50 50 690V 40 40 kA (rms) Rated service short-circuit Ics Breaking capacity 220V 50 65 415V 50 65 500V 50 65 600V 50 50 690V 40 40 Rated short time withstand current kA (rms) 50 1 second Icw 65 kA (rms) 40 3 seconds Icw 50 kA (peak) 143 Rated short-circuit 415V 143 making capacity 500V 143 143 600V 143 105 690V 84 84 Watt Power dissipation at In (fixed breaker) W 16 11 Watt Power dissipation at In (withdrawable) W 33 22 630 800 1000 1250 20000 10000 5000 690 1000 8000 3&4 100% S N 1 1 S 1 20000 10000 5000 690 1000 8000 3&4 100% N 1 H 2 S 1 20000 10000 5000 690 1000 8000 3&4 100% N 1 H 2 S 1 20000 10000 5000 690 1000 8000 3&4 100% N 1 H 2 50 50 50 50 40 65 65 65 50 40 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 40 143 143 143 84 39 75 65 50 143 143 105 84 27 53 50 40 143 143 143 84 63 127 65 50 143 143 105 84 43 86 80 50 176 176 143 105 23 49 50 40 143 143 105 84 106 211 65 50 143 143 105 84 68 135 80 50 176 176 143 105 36 77 50 40 143 143 143 84 175 351 65 50 143 143 105 84 105 211 80 50 176 176 143 105 60 128 X Temperature deratings Free Air (1) The M-PACT Plus ACBs may operate at higher ambient temperatures than 40°C in certain installation conditions. In this case the current rating in Amperes should be reduced as indicated below. Ambient temp. around the breaker Current rating (A) above 40°C Rated current (A) 800 1000 1250 1600 2000 2500 3200 4000 50°C 800 1000 1250 1600 2000 2450 3200 3727 60°C 800 1000 1250 1445 2000 2232 3200 3367 The figures specified apply to withdrawable ACB’s with flat face vertical copper connections. No derating up to 50°C for 5000A - 6300A. Other values on request . (1) Protection degree IP00. For use in enclosures with interior temperatures of 40°C to 60°C the relevant IP values can be applied. A.8 Rated short-circuit capacity In accordance with IEC 947-2 at 415V Breaker range Rating (A) S 400 to 4000 N H C Type Fixed or withdrawable 400 to 4000 Fixed or withdrawable 800 to 4000 Fixed or withdrawable 5000, 6300 Fixed or withdrawable Icu Ics Icw 1 sec 500 ms 50kA 50kA 50kA - 65kA 65kA 65kA - 80kA 80kA 80kA - 100kA 100kA - 100kA Recommended minimum copper size In accordance with IEC 947-2 Rating (A) Copper / phase 400 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 2 x 50 x 5 2 x 50 x 5 2 x 50 x 5 2 x 60 x 5 2 x 50 x 10 2 x 50 x 10 3 x 50 x 10 4 x 50 x 10 4 x 100 x 10 4 x 100 x 10 + 1 x 100 x 5 8 x 60 x 12 12 x 60 x 12 or 6 x 120 x 12 M-PACT Plus 2000 2500 3200 4000 5000 5000 6300 6300 S 1 20000 10000 5000 690 1000 8000 3&4 100% N 1 H 2 S 1/2 20000 10000 5000 690 1000 8000 3&4 100% N 1/2 H 2 S 1/2 20000 10000 5000 690 1000 8000 3&4 100% N 1/2 H 2 S 2 20000 10000 5000 690 1000 8000 3&4 100% N 2 H 2 S 2 20000 10000 5000 690 1000 8000 3&4 100% N 2 H 2 5000 2500 2500 690 1000 8000 3 C 3 3000 1500 1000 690 1000 8000 3 C 3 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 100 100 100 100 100 100 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 50 50 50 50 40 65 65 65 50 40 80 80 80 65 60 100 100 100 100 100 100 50 40 143 143 143 84 287 574 65 50 143 143 105 84 196 392 80 50 176 176 143 105 98 209 50 40 143 143 143 84 224 490 65 50 143 143 105 84 224 490 80 50 176 176 143 105 163 347 50 40 143 143 143 84 224 490 65 50 143 143 105 84 224 490 80 50 176 176 143 105 163 347 50 40 143 143 143 84 418 888 65 50 143 143 105 84 418 888 80 50 176 176 143 105 418 888 50 40 143 143 143 84 571 1224 65 50 143 143 105 84 571 1224 80 50 176 176 143 105 571 1224 100(1) 55 220 220 220 570 975 100(1) 55 220 220 220 1510 (1) 500ms Performance data 1600 A B C X Dimensions (mm) Frame size Rating (A) Poles Version (1) Height (2) Length (3) Depth (4) 1 400 to 2500 3 W F W F W F W F W F W F W F W 440 430 440 430 440 430 440 430 440 430 440 430 578 518 578 329 329 429 429 419 419 549 549 419 419 549 549 969 902 969 390 328 390 328 392 328 392 328 482 328 482 328 729 411 729 4 2 800 to 3200 3 4 2 4000 3 4 3 5000 3 3 6300 3 (1) Version W = Withdrawable F = Fixed (2) Height (H) is from mounting surface to highest part of the ACB (3) Length (L) is distance between widest part of the breaker (4) Depth (D) is from the cubicle door to the rear moulding A.9 M-PACT Plus Selectivity/Discrimination Downstream device Upstream device M-PACT Plus ACB Technical overview M-PRO 17 Plus & 18 Plus A B Ir factor 1.6 Ist factor 1.5 STD timing 0.2 Instantaneous : 30kA minimum Record PlusTM MCCB SMR1s SMR2 Ir factor 1.6 Ist factor 1.5 STD set at one band higher Instantaneous : 30kA minimum X Ir factor 1.6 LTD class 20 Ist factor 1.5 STD timing 0.2 A2S band 0.1 Ir factor 1.6 LTD set at one class higher Ist factor 1.5 STD set at one band higher 2 A S set at one band higher * LTD set at class 20 Selectivity/Discrimination M-PACT Plus Upstream Frame 1, N and H ranges In (A) 400 800 1000 1250 1600 Frame 2, N and H ranges 2000 Downstream Redline G60/100/GT25 Surion GPS Hti S90 Record PlusTM FD160 E, S, N, H & L FE160 N, H & L FE250 N, H & L FG400 N, H & L FG630 N, H & L C M-PRO 30/40 Record PlusTM MCCB SMR1 FK800 N, H & L FK1250 N, H & L FK1600 N and H M-PACT Plus Frame 1 Frame 2 2500 1000 1250 1600 2000 2500 3200 4000 Selectivity limit in kA All T T T T T T T T T T T T T T All All T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T All All All 250 350 400 400 500 630 All 1000 1250 1600 400 800 1000 1250 1600 2000 2500 T T T T - T T T T T T T T - T T T T T T T T T T - T T T T T T T T T T T T - T T T T T T T T T T T T T T - T T T T T T T T T T T T T T T T T - T T T T T T T T T T T T T T T T T T T - T T T T T T T T T T T - T T T T T T T T T T T T T - T T T T T T T T T T T T T T T - T T T T T T T T T T T T T T T T T - T T T T T T T T T T T T T T T T T T - T T T T T T T T T T T T T T T T T T T - T T T T T T T T T T T T T T T T T T T T * T = Total: selective until the Icu of the downstream device OR the Icu of the upstream device Weights (kg) S range Fixed pattern ACB 400 to 1600A 2000 to 2500A 800 to 3200A 4000A 5000A Withdrawable ACB A.10 N range H range C range Frame 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole 1 1 2 2 3 36 43 53 53 N/A 44 54 68 68 N/A 39 43 53 53 N/A 49 54 68 68 N/A N/A N/A 53 53 N/A N/A N/A 68 68 N/A N/A N/A N/A N/A 170 N/A N/A N/A N/A N/A Frame 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole 400 to 1600A 2000 to 2500A 800 to 3200A 4000A 5000A 6300A 1 1 2 2 3 3 63 72 90 111 N/A N/A 77 90 117 144 N/A N/A 68 72 90 111 N/A N/A 84 90 117 144 N/A N/A N/A N/A 90 111 N/A N/A N/A N/A 117 144 N/A N/A N/A N/A N/A N/A 250 265 N/A N/A N/A N/A N/A N/A Cassette only Frame 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole 3 Pole 4 Pole 400 to 1600A 2000 to 2500A 800 to 3200A 4000A 5000A 6300A 1 1 2 2 3 3 27 29 37 58 N/A N/A 33 36 49 76 N/A N/A 29 29 37 58 N/A N/A 36 36 49 76 N/A N/A N/A N/A 37 58 N/A N/A N/A N/A 49 76 N/A N/A N/A N/A N/A N/A 75 80 N/A N/A N/A N/A N/A N/A M-PACT Plus M-PRO 17 Plus M-PRO protection relays Electronic trip units There are four types of electronic trip unit (ETU): 1. M-PRO 17 Plus - Rotary switch settings 2. M-PRO 18 Plus - Rotary switch settings and display feature 3. M-PRO 30 - Digital settings and display feature (only for frame 1 & 2) 4. M-PRO 40 - Digital settings and display feature (only for frame 1 & 2) Protection relays M-PRO 18 Plus A 11 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 12 1 5 6 2 7 3 8 9 10 4 Long time setting Short time setting Unrestricted earth fault setting* Test connector Instantaneous setting Reset switch* Short time delay Curve followed Unrestricted earth fault delay setting* Healthy light emitting diode Liquid crystal display Scroll switch B C X * Not in frame 3 M-PRO 30/40 (frame 1&2) 3 4 5 6 2 1 7 8 1. Overload/short-circuit protection curve incorporating 7 red LED's; indication of fault type. 2. Earth fault protection curve incorporating 2 red LED's for fault indication. 3. LCD 2 line display for clear indication of menus, settings, recorded information. 4. Warn / alarm LED 5. Healthy LED 6. Selectable manual / automatic reset button. 7. Four button tactile key pad. 8. Multi pin socket for test box and/or portable power box. A.11 M-PACT Plus M-PRO curve Terminology NORMAL A ST Ir Isd Ig Current in multilples of I B C X Ii Current in multiples of Ir Time to trip (sec) Technical overview Time to trip (sec) LT In Ir Isd Ii If or Ig Ibr LT ST ACB ETU LCD LED PMCA MCR HSISC UEF REF SEF APU SI EI VI NO NC PAMM = = = = = = = = = = = = = = = = = = = = = = = = = Nominal Current Rated Current Short time current Instantaneous Current Unrestricted Earth Fault Current Current Flowing Through Breaker Long time Short time Air Circuit Breaker Electronic Trip Unit (M-PRO) Liquid Crystal Display Light Emitting Diode Primary Contact Maintenance Alarm Making Current Release High Set Instantaneous Short Circuit Unrestricted Earth Fault Restricted Earth Fault Standby Earth Fault Auxiliary Power Unit Standard Inverse Extremely Inverse Very Inverse Normally open (contact) Normally closed (contact) Plant Associated Memory Module Breaker rating can be set from 40% to 100% of the nominal value, using the long time pickup switch. The unit will be in normal condition for all the currents less than the rated value. So the curve is parallel to the time axis. Warning Do not disconnect trip unit when breaker is in service. Do not change settings on the trip unit when breaker is in service. Do not interchange trip units between breakers. These trip unit conform to IEC 60947-2, annex F. A.12 M-PACT Plus M-PRO protection relay electronic trip units M-PRO 17 Plus & 18 Plus The rated current of the breaker Ir can be set from 40% to 100% of the nominal value In, using the long time pickup switch. The breaker status will be “Normal” for current Ibr less than the rated value set Ir. The top most portion of the curve indicates this region of normal operation where the line runs parallel to the time axis (Y-axis). The ETU is capable of providing protection in the Long time zone in accordance with IEC Class 20. If the current Ibr is greater than the “Short Time pickup” set by the user on the M-PRO the unit will initiate a trip after the set delay time. There are eight different settings for the ST pickup levels with least at 1.5 times the Ir to maximum of 12 times (10 times for Frame 3) Ir. Also there are seven definite delay settings for the Short Time. Depending on the type of installation and application, it is possible to set the tripping curve of your trip unit using the parameters presented below. Long-time protection The long-time protection function protects cables (phase and neutral) against overloads; this function is based on true RMS measurements. Switch number 1 is for the long time pickup setting (Ir) as shown in the unit diagram. User can choose the LT pickup as 0.4 to 1.0 x In in steps of 0.1. Type of curve Protection curve is in accordance to IEC (International Electro-technical Commission) IEC Curve IEC Curve specification is as follows: • For 1.05 x Ir there will be no tripping with in 2 hr • For 1.5 x Ir tripping time will be < 480 seconds • For 7.2 x Ir tripping time will be < 20 seconds Protection relays When the ETU senses that the load current greater than the rated Ir, it goes into “overload condition”. On the M-PRO 18 Plus this is indicated on the display on breaker status page that breaker is in “overload pickup”. Current protection A B The unit also has a instantaneous pick up zone which is set by the user wherein if the current Ibr through the breaker is greater than pickup set the unit will initiate a trip with no intentional time delay. Instantaneous protection feature overrides the fixed time short-circuit protection. There are eight possible different settings for the pickup including OFF. C X The earth fault protection feature is optional and detects any fault current downstream of the breaker. An intentional user defined time delay can be set before the unit can initiate a trip after having seen the fault . There are five settings for the unrestricted earth fault with minimum setting at 0.4 to a maximum of 1.0 times In. M-PRO18 Plus - Example of LED display status A.13 M-PACT Plus Technical overview Timing & accuracy Timing shall be as per the curve selected, with accuracy of ± 10%. A B C X Example For 1000A breaker if the long time setting is at 0.5 then for IEC selected curve LT pick up is at Ir = In x 0.5; 1000 x 0.5 = 500A For 1.05 x Ir i.e. at 1.05 x 500 = 525A there will be no tripping with in 2 hr For 1.5 x Ir i.e. at 1.5 x 500 = 750A tripping time will be with in 480 seconds. For 7.2 x Ir i.e. at 7.2 x 500 = 3600A tripping time will be <20 seconds. Short-time protection The short-time protection function protects the distribution system against impedant short-circuits. The short-time tripping delay can be used to ensure discrimination with a downstream circuit breaker. This function carries out true rms measurements. Switch number 2 is for the short time pickup setting (Isd), as shown in the unit diagram, which is dependent on the LT switch setting as 1.5, 2, 3, 4, 6, 8, 10 & 12 x Ir. In case of frame 3 it is 1.5, 2, 3, 4, 6, 8 & 10 x Ir. Switch number 7 is for a short time delay setting as 0.1, 0.2, 0.4, 0.5, 0.6, 0.8 & 1.0 second for frame 1 & 2 and 0.1, 0.2, 0.3 & 0.4 for frame 3. Timing & accuracy Tripping time is dependent on delay setting. If the fault current is detected then,the unit intiates a trips after waiting up to the set delay time. The accuracy of pickup is ±10% of the set value. Example For 1000A breaker if the long time pickup setting is at 0.4 & short time pickup setting is at 10 with short time delay at 0.5 then, LT pick up is at Ir = In x 0.4; 1000 x 0.4 = 400A ST pick up is at Isd = Ir x 10; 400 x 10 = 4000A At 4000A, breaker goes into ST pickup and trips after the delay 0.5 sec. Instantaneous protection The instantaneous protection function protects the distribution system against solid short-circuits. Contrary to the short-time protection function, the tripping delay for instantaneous protection is not adjustable. The tripping order is sent to the circuit breaker as soon as current exceeds the set value. This function carries out peak measurements. Switch number 5 is for the instantaneous pickup (I i). User can choose the instantaneous pickup as OFF, 2, 3, 4, 6, 8, 10 & 12 x In. For OFF setting instantaneous will be disabled. In case of frame 3 the settings are: OFF, 2, 3, 4, 6, 8 and 10 x In. Time & accuracy If current greater than the set INST pickup is detected, the unit will initiate a trip pulse, with in 50msec of having seen the current . The accuracy of pickup is ±10% of the set value. Example For 1000A rated breaker if the instantaneous setting is at 10 then, instantaneous pick up is at Ii = In x 10; 1000 x 10 = 10000A If the current is more than 10000A then unit trips instantaneously. Unrestricted earth fault protection for frame 1 & 2 only The unrestricted earth fault-protection function protects the the distribution system against downstream earth fault in the system. The unrestricted earth fault tripping delay can be used to ensure discrimination with a downstream circuit breaker. The tripping order is sent to the circuit breaker as soon as current exceeds the set value. This function carries out true rms measurements. Switch number 3 is for the unrestricted earth fault pickup (Ig). User can choose the UEF pickup values as OFF 0.4, 0.6, 0.8 & 1 x In. Switch number 9 is for a UEF time delay setting as 0.1, 0.2, 0.4, 0.6, 0.8 & 1.0 second. Timing & accuracy Tripping time is dependent on delay setting. If pick up detected, the unit intiates trips after waiting up to the set delay time. The accuracy of pickup is ±10% of the set value. Example For 1000A breaker if the unrestricted earth fault setting is at 0.8 with unrestricted earth fault delay at 0.2sec then, UEF pick up is at Ig = In x 0.8; 1000 x 0.8 = 800A At 800A of leakage earth fault current , breaker goes into UEF pickup and trips after the delay 0.2sec. A.14 M-PACT Plus Protection of the fourth pole on four-pole circuit breakers(1) (Factory setting) Protection of the neutral conductor depends on the distribution system and the cross-section of the conductor used. Modes of neutral protection (factory settings) There are three types of neutral protection: • Neutral unprotected (0%) • Half neutral protection (50%) • Full neutral protection (100%) Protection settings available in frame 1 and frame 2 Half neutral protection(2) The cross-sectional area of the neutral conductor is half of the phase conductors. The long-time current setting Ir for the neutral is equal to half the setting value. The short-time pick-up Isd for the neutral is equal to half the setting value. Full neutral protection The cross-sectional area of the neutral conductor is same as that of the phase conductors. The long-time current setting Ir for the neutral is equal to the set value. The short-time pick-up Isd for the neutral is equal to the set value. Timing & accuracy Tripping time is dependent on setting. For long time & short time settings, after pick up, the unit trips, waiting up to the set delay time as mentioned above. The accuracy of pickup is ±10% of the set value. Parameter Pickup settings Delay settings Long time trip (Ir) 0.4, 0.5, 0.6, 0.7, 0.8, Fixed 0.9 & 1.0 xIn Short time trip (Isd) Instantaneous trip (Ii) 1.5, 2, 3, 4, 6, 8, 0.1, 0.2, 0.4, 0.5, 0.6, 10 & 12 xIr 0.8 & 1.0 second OFF, 2, 3, 4, 6, 8, N/A Protection relays Neutral unprotected The distribution system does not require protection of the neutral conductor. Example For a breaker rating of 1000A, LT pickup setting of 1.0 & ST pickup setting of 10, LT pick up is at Ir = In x 1; 1000 x 1=1000A ST pick up is at Isd = Ir x 10; 1000 x 10 =10000A. If neutral is none rated then there is no neutral protection. If neutral is half rated then for neutral protection, LT pick up is at 0.5 x 1000 = 500A & ST pickup is at 10 x 500 = 5000A. If neutral is full rated then for neutral protection, LT pick up is at 1.0 x 1000 = 1000A & ST pickup is at 10 x 1000 = 10000A. 10 & 12 xIn Unrestricted earth OFF, 0.4, 0.6, 0.8 0.1, 0.2, 0.4, 0.6, Fault trip (Ig) & 1xIn 0.8 & 1.0 second A B Protection settings available in frame 3 Parameter Pickup settings Delay settings Long time trip (Ir) 0.4, 0.5, 0.6, 0.7, 0.8, Fixed C 0.9 & 1.0 xIn Short time trip (Isd) 1.5, 2, 3, 4, 6, 8, & 10 xIr 0.1, 0.2, 0.3, 0.4 Instantaneous trip (Ii) OFF, 2, 3, 4, 6, 8,10 xIn N/A X (1) This is a configuration parameter in M-PRO Plus. (2) Set the LT setting to 1.0 while using half neutral protection. A.15 M-PACT Plus Technical overview MCR making current release (1) Making current release (MCR) is a breaker protection which prevents the ACB from making and latching onto a current that is greater than its make and latch capability, typically a short-circuit . In order to ignore the transient response of the system under different power factors the first millisecond of any high level signal is completely ignored. After this the signal must exist for at least 1ms in order to cause a trip, to reduce the likelihood of trips occurring due to signal or noise spikes. As default the MCR protection will be enabled , and the pick-up level set to 50kA. On an M-PRO Plus without auxiliary power, the unit will be powering up as the ACB begins to close, i.e. as soon as any current begins to flow through the breaker. It is, therefore, necessary for the MCR protection and trip circuitry to be enabled at power-up. If the M-PRO Plus detects an MCR condition it will initiate a trip. MCR protection is only during closing of the breaker, MCR will operate only when the bus bar switch is open. A (1) Not applicable for frame 3 B Timing & accuracy Timing for the MCR is less than 10msec assuming a 50Hz or a 60Hz sinusoidal waveform, with accuracy of 0 to -20%. C Reset mechanism (2) X The M-PRO Plus unit will incorporate a mechanical reset mechanism. When the M-PRO unit initiates the breaker to trip, the reset button will be forced out through the front of the M-PRO Plus unit , this can be clearly seen at the front . The breaker cannot be closed untill this switch has been reset or pushed in. Reset will be manual or automatic - user selected position. (2) Not available in frame 3 Thermal memory If the M-PRO Plus has an auxiliary power supply, the thermal content will continue to decrease after the trip has occurred (following the cooling method in use), and therefore, if the ACB is re-closed soon after the trip, the thermal effect of the previous current will have been remembered, i.e. the unit will have a thermal memory. For M-PRO 17 Plus/18 Plus in the presence of auxiliary power supply, the thermal memory duration will be defaulted to 20 min. Healthy LED After the power up healthy LED starts blinking. Normally, when the unit is healthy, LED blinks like a heartbeat . If the healthy LED is continuously ON or OFF, then it is an indication that unit is not operating normally. Test connector & test box A 26-pin connector is provided at the bottom side of the unit with a protection cover over it . The testing personnel for testing the healthiness and configuration of the unit use this. The M-PRO test box is used as a means of powering up an M-PRO Plus, simulating faults by secondary injection or for performing a forced trip of the breaker. M-PACT Plus breaker will be in the test mode while M-PRO Plus is connected to test box through test connector. Connection Ensure that the battery is fully charged before attempting any work that may require an extended operating period. Full charge of a flat battery will be achieved in an 8-hour charging period. To maintain the battery life span it is not advisable to charge a battery that still holds a charge, so always allow the battery to discharge fully before re-charging. Turn the test box on using the “Power On/Off” button; the lamp above the switch should illuminate. Connect the test box to the M-PRO Plus via the front panel 26-pin connector using 15-pin to 26-pin converter. Do not test the M-PRO Plus with the charger still connected, as this will disable power to the M-PRO Plus. The thermal memory is a means to simulate cooling characteristics of the load, when the breaker is in series with the said load has tripped due to overload condition (long time region) The overload condition may be caused by: • Repetitive motor starting • Loads fluctuating near the protection settings • Repeated circuit breaker closing on a fault Even very short overloads produce a temperature rise that is stored in the memory. This information stored in the thermal memory reduces the tripping time. The thermal content will start from zero at power-up. On an M-PRO Plus, which has no auxiliary power supply, if the ACB is re-closed soon after a trip, any thermal effect of the current flowing prior to the trip will be forgotten. A.16 Note: should the “Battery Low” warning light illuminate at any time then there is approximately 20 minutes of usage left in the battery before power will be removed from the M-PRO Plus. M-PACT Plus Re-charging Ensure that the ambient temperature is between +15ºC and +50ºC. With the test box unplugged from M-PRO Plus, connect the charger unit via the charger socket at the top of the test unit . The “Battery Charging” lamp should illuminate. Wait a few seconds and ensure that the lamp remains illuminated, as there can be enough power in the charger to illuminate this lamp for a short period of time even with the mains supply off. MCR test(1) This test use secondary injection. A DC signal is imposed on the Rogowski input circuits of the M-PRO Plus. Red, yellow and blue phases may be tested individually. The neutral phase does not offer this protection. The making current release (MCR) is set to 50kA as standard and is active only whilst the ACB is open/closing, and switches off when closed and latched. With the ACB open, the test box on and connected; turn “Trip Enable“ on and select the “MCR Phase” test . Start the test by pressing the “Test Now” button on the test box. Immediately the M-PRO Plus recognizes the fault it will try to fire the sensitive trip. (1) Not available in frame 3 Powering M-PRO Plus The test box may be used as a simple power box to facilitate viewing of faults (e.g. after a trip) or the history of trips. The feature may also be required for changing protection settings. For setting of the inputs, outputs and re-configuring the factory settings, the breaker must be open. In this case some form of external power is mandatory (power box, APU or test box). Portable power box only for M-PRO 30/40. For M-Pro 30 and 40, the auxiliary power supply is provided as standard. Protection relays Calibration The equipment does not require calibration. It is recommended that the general condition and functionality be checked before each usage. The M-PRO Plus power supply may be damaged if the test connector is misinserted. Force trip This is the final test available on the test box. This test is a quick way of tripping the breaker in order to test the mechanical operation and reset mechanism. To perform a forced trip, turn the test box on, connect to M-PRO Plus, turn “Trip Enable” on and select “Force Trip”. Pressing the “Test Now” button will cause the M-PRO Plus to initiate a trip, reporting the trip as normal (the fault level reported in the trip history is the highest phase current at the time the trip was initiated). A forced trip clears itself on removal of the test box. There is no need to clear the existing fault as is necessary for the other tests. A B C X A.17 M-PACT Plus LCD display In M-PRO 18 Plus user can scroll different pages of the display using the scroll switch. There are four pages in the display menu which scroll as follows: Technical overview 1) Phase currents L1 phase current (Amps) L2 phase current (Amps) L3 phase current (Amps) Range is from 0 to 9999A. A B If current is less than 8% of breaker rating then it shall be displayed as <####A. If current is greater than 9999 then it will be displayed as 9999 in frame 1 and frame 2 In frame 3 readings above 9999A are displayed with ‘k’ replacing ‘000’. If breaker is open, the currents will be displayed as 0. TRIP SC L1, TRIP SC L2, TRIP SC L3, INDICATES BREAKER TRIPPED ON SHORT-CIRCUIT TRIP SC N, TRIP LT L1, TRIP LT L2, TRIP LT L3, INDICATES BREAKER TRIPPED ON OVERLOAD TRIP LT N, TRIP UEF, O/L PICK UP, INDICATES BREAKER TRIPPED ON EARTH FAULT INDICATES BREAKER IS IN OVERLOAD REGION NORMAL, INDICATES BREAKER IS IN NORMAL CONDITION L1 L2 L3 <### <### <###A TRIP INST, INDICATES BREAKER IS TRIPPED ON INSTANTANEOUS 2) Neutral and UEF current FORCED TRIP, Neutral current shall be displayed Scroll in the following format switch N = 0.5 x In UEF <###A <###A INDICATES BREAKER IS TRIPPED THROUGH FORCE TRIP SELF TEST TRIP. • History will be updated of the last trip occurred at the next power up of the unit overwriting the previous history. Scroll C 3) Breaker status switch BREAKER STATUS NORMAL X Scroll 4) History switch TRIP HISTORY NO FAULTS Scroll switch Display features • After startup the display will be blank for the first 2 seconds. The first menu (all three phase currents) is displayed by default . (After power up) • The user can view other pages by pressing the scroll switch (provided on the front panel). • Backlit will function only when auxiliary power is provided. • The backlit can be turned on by pressing the Scroll switch provided on the front panel. Backlit ON time is one minute. On subsequent presses of the scroll key various display pages can be viewed & backlit time starts for one minute after last press of the scroll switch. • Breaker status can be following: (similar is for the history) A.18 Neutral and UEF page • If UEF option is not provided for the unit , this page displays only neutral current . • If neutral protection is not provided then neutral page will not be displayed. • If neutral is not enabled, only UEF is provided, then only UEF current will be displayed. • If neutral is enabled, and UEF is disabled, then only feutral current will be displayed. • If both neutral and UEF are not provided then this page will be removed, only 3 pages will scroll on the display. N = 0.5 x In <###A UEF <###A N = 0.5 x In ¤ Half rated neutral N = 1.0 x In ¤ Full rated neutral Wiring diagram M-PRO Plus For frame 1, 2 & 3 refer pages C.5 and C.6 M-PACT Plus M-PRO protection relays - Specifications Trip unit O M-PRO 18 Plus 18Plus* L H O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O(1) O O O O O O(1) O O O O O O O O O O O O O O O O O O O O O O O O O(5) O(5) O(5) O(5) O O O O(2) O O O O(2) O O O O O O O O O O O O O O O O O O O O O O O O O O(3) O O(2) O O(3) O O(2) O O O O O O O O O O O O O O O O O O O O O O O O O O(4) O O O O O(4) O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O(5) O M-PRO 40 H O O O M-PRO 30 L O(5) O O O O O O O O O O O O O Protection relays Long Time Protection Pickup adjustable from 0.4 to 1.0x In in steps of 0.1 Pickup adjustable from 0.4 to 1.0x In in steps of 0.01 Long Time Characteristic To IEC 947-4, Class 20 To IEC 947-4, Class 40 (& IEC255, 80 combinations) Fixed Short Time Protection 1.5, 2, 3, 4, 5, 6, 8 ,10 & 12 x Ir (frame 1 & 2 size) 1.5, 2, 3, 4, 6, 8 & 10 x Ir (frame 3 size only) Instantaneous Trip (Ii) OFF, 2, 3, 4, 6, 8 ,10 & 12 x In (frame 1 & 2 size) OFF, 2, 3, 4, 6, 8 & 10 x In (frame 3 size only) Fixed (MCR function) Short time delay 0.1, 0.2, 0.4, 0.5, 0.6, 0.8, 1.0s. (frame 1& 2 size) 0.1, 0.2, 0.3, 0.4s. (frame 3 size only) Inst to 1.0s in 0.1 steps Short time I2t Protection (Inverse Short Circuit) 0.1 times selected long time Pick-up, 1.5, 2, 3, 4, 6, 8, 10 and 12 x Ir Neutral Protection Fixed Neutral Protection (50% or 100%) (Factory setting) Adjustable Neutral Protection Earth fault protection Unrestricted Earth Fault (UEF) (6) Restricted Earth Fault (REF) Standby Earth Fault (SEF) Combinations of UEF, REF & / or SEF Earth fault pickup, OFF, 0.1 to 1.0x In. 0.01In steps Earth fault pickup, OFF, 0.4 to 1.0x In. 0.2In steps Time Delay: <100ms, 0.1, 0.2, 0.4, 0.6, 0.8 and 1.0s Time Delay: Inst. To 1.0s in 0.1 steps Earth fault cropping, 1 (OFF), 1.5, 2, 2.5, 3, 4, 5 and 6 Thermal Memory / Cooling Time Fixed to at time constant of 20 minutes Adjustable time constants, inst., 10,20,30,45,60,120,180 mins Trip Indication Healthy Unit LED Warning & / or Alarm LED Discrete LED’s for each fault type Remote Indication (Fault code via communication facility) Fault Analysis Existing Fault Notification Historic Trips (last 16) Historic Fault (last trip only) System Status Breaker Status Auxiliary Power Supply Output Relays Trip Initiated HV Inter trip (linked to REF) Watchdog/Watchdog disable (No output relay) Remote ACB Switching (Open / Close via Comms. Unit) Communications MODBUS Protocol Trip Reset Manual (Push Button) - Frame 1 & 2 Automatic - Frame 1 & 2 Monitoring Ammeters Load Monitoring Operations Counter Trip Alarm Contact (mechanical C/O) Main Contact Maintenance Indication Inputs 24-48V d.c. 110-130V d.c. or 110-250Va.c. Auxiliary Power Supply Plant Associated Memory Module (PAMM) Circuit Protection Memory Test Connector 16 way DIL Heater 26 way D-Type M-PRO 17 Plus 17Plus* A B C X O O O O O O O O O O O O O O O O (1) Mpro30 units can be provided with REF as standard feature to replace UEF but please specify correct order code. (2) Remote indication becomes a standard feature when the Communications facility is specified. (3) Standard feature when Restricted Earth Fault option is specified. (4) Feature not available if communications option is specified. (5) Requires permanent auxiliary power to operate continuously. (6) For 3P breaker, 4 wires system, please order rogowski coil and CT separately. L = Low voltage inputs H = High voltage inputs Standard O Optional O A.19 M-PACT Plus Technical overview M-PRO protection relays M-PRO 30/40: Any combinations of two or three types of protection can be factory pre-set earth fault curve cropping: available for unrestricted or stand-by earth fault options. This feature enables the user to vary the tripping time in accordance with the prospective earth fault detected. A ‘Cropping Factor’ may be selected which is a multiple of the chosen earth fault pick-up current . This selects the desired level of current at which the fixed time delay becomes effective. Earth fault protection zone diagram Plant associated memory module M-PRO 30/40 Module (PAMM), fitted remote from the protection unit that stores the M-PRO settings. This feature reduces set-up time by down loading the original data if the M-PRO is replaced or the moving portion of the ACB is changed. The new unit will not require re-configuration while ensuring error-free replacement and maintenance. A Adjustment method of setting M-PRO 17 Plus: front panel rotary switches. M-PRO 18 Plus: front panel rotary switches. M-PRO 30/40: four key tactile keypad. B C X Neutral pole protection M-PRO 17/18 Plus: factory-set to OFF, 50% or 100% M-PRO 30/40: customer selectable between ‘OFF’, 50% and 100%. Thermal memory (with permanent auxiliary power supply only) To protect against unacceptable recurring or cyclic overloads the M-PRO will track and memorise the thermal effects of load current while the breaker is on line. Tripping will be initiated when the cumulative thermal effect of cyclic overloading reaches a predetermined level. M-PRO 17/18 Plus: factory adjustable time constants (auxiliary power supply mandatory). M-PRO 30/40: customer adjustable time constants (auxiliary power supply included). Trip alarm switch All M-PRO’s: A 1 x NO or 1 x nc switch is operated by the protection management unit trip mechanism when the M-PRO has initiated a trip. Tripping is indicated until the reset button on the M-PRO is pressed. In case of automatic reset an impulse will be generated. A.20 RESET function All M-PRO’s: manual or auto reset function. (except specific version) Inputs M-PRO 30/40: are provided with four opto-coupled remote inputs to initiate alarm signals or tripping of the circuit breaker in response to signals indicating a change in the state of devices remotely positioned in the system. The supply voltage of the remote inputs are 24/48V DC (M-PRO 30L or M-PRO 40L) and 110/250V AC or 110/130V DC (M-PRO 30H or M-PRO 40H). M-PACT Plus Outputs M-PRO 30/40 are provided with four relay outputs to permit remote indication of changes in the state of the circuit breaker and its protection, e.g. M-PRO initiated trip / watchdog alarm / breaker main contact maintenance alarm / remote fault / pre-trip alarm/load monitoring. This facility may also be used to transmit a remote trip signal to a high voltage circuit breaker. An external power supply is required to permit remote output facilities. Communication M-PRO 40: by means of a RS485 4-wire serial link using a MODBUS protocol, M-PRO protection units can be linked for remote communication to provide a complete system management and control. Communication occurs in both directions. Remote switching - each unit can be remotely opened and closed Remote adjustment - user settings and inputs may be altered by remote command Monitoring - ammeters, load monitoring, operations counter, existing faults, trip history Protection relays Load monitoring M-PRO 30/40 offers two alternative facilities of monitoring the load, pre-alarm or load shedding. Pre-trip alarm: this alarm will provide a warning when the current measured is above 1.1x Ir and the thermal content is above 60% thus indicating that a trip is likely to occur. Load shedding: load shedding will have two user configurable current levels, the level which shedding will start , and the level at which shedding will stop (auxiliary power supply mandatory). A B C X A.21 M-PACT Plus * ** Trip curves* Overload & delayed short-circuit curves at Ir = 1.0 x In N=I/Ir for overload & delayed short-circuit N=I/In for instantaneous & ground M-PRO Plus - frame 1 & frame 2 Technical overview (2500 used as example) 10000 LT has 7 available LT has 7 available settingsset tings : 0.4 toto 1.01.0xI x ln innsteps 0.1 of 0.1 0.4 in softeps Indicated: 1.0 x ln Indi cated : 1 .0 x I n 1000 A 100 B X Time to trip in seconds (s) C ST has 8 available set tings : 10 ST has 8 available settings: 1.5,2,2, 3,6,4,8, 6, 10x lr& 1 2 x Ir 1.5, 3, 4, 10 8, & 12 Indicated: 1.5:x1lr,.56 x x lrI r, & 12 Indi cated 6 xx lrI r & 12 x Ir 1 ST Dadjustable adjus table: STD 0.1, 0.4,0.4, 0.5, 0.6, & 1.0s 0.1,0.2, 0.2, 0.5,0.80.6, 0.8 Indicated: 0.1, 0.5, & 1.0s & 1.0s Indi cated : 0 .1, 0.5 & 1 .0s 0.1 Inst antane ous re le as e Instantaneous release 0.01 Making Cu rre nt Making Current Release: 50kA50k A Re le ase: 0.001 0.1 1 10 Current as multiples of N** A.22 100 M-PACT Plus * ** Trip curves* Overload & delayed short-circuit curves at Ir = 1.0 x In N=I/Ir for overload & delayed short-circuit N=I/In for instantaneous & ground M-PRO Plus - frame 3 10000 Trip curves LT has 7 available set tings : LT has 7 available settings 0.4 to 1.0xI n in s teps of 0.1 0.4 to 1.0 x ln in steps of 0.1 Indi cated Indicated: 1.0:x1ln.0 x I n 1000 A Time to trip in seconds (s) 100 10 B ST has 7 available ST has 7 available settings: set tings : 1.5, 3, 4, 1.5,2, 2, 3,6,4,8 &6,108x&lr 10 xIr Indicated: 1.5 x lr, 6 x lr & 10 x lr Indi cated : 1 .5 x I r, 6 x I r & 10 x I r C X ST D adjus table: STD 0.1,adjustable 0.2, 0.3 & 0.4 0.1, 0.2, 0.3, & 0.4s Indi cated Indicated: 0.1 : 0 .1 1 0.1 Inst antane ous Instantaneous release 8 xelr 8 x I r re le as 0.01 0.1 1 10 100 Current as multiples of N** A.23 M-PACT Plus * ** Trip curves* Overload & delayed short-circuit curves at Ir = 1.0 x In N=I/Ir for overload & delayed short-circuit N=I/In for instantaneous & ground M-PRO 30/40 - frame 1 & 2 Technical overview 100000 LT set at 1 x ACB rating (In) LTD set at 35 s SC set at 6 x Ir SCD = 3 s ST set at 12 x Ir STD set at 300 ms Type H: Instantaneous release at 80kA 10000 1000 LTD has 16 available settings 0,25...35 seconds at 7.2 x Ir Indicated: 5 and 35 seconds A B C X Time to trip in seconds (s) 100 LT set at 1 x ACB rating, In LTD set at 5 s ST set at 1.5 Ir STD set at 300 ms Type S: Instantaneous release at 50kA SC has 8 available settings 1.5, 2, 3, 4, 6, 8, 10, 12 x Ir Indicated: 6 x Ir 10 SCD is fixed at 10 x the configured LT curve Indicated: 3.5 seconds 1 Instantaneous release: Type S 50kA Type N 65kA Type H 80kA Indicated: S and H ST has 8 available settings 1.5, 2, 3, 4, 6, 8, 10, 12 x Ir Indicated: 1.5 x Ir and 12 x Ir STD adjustable: Inst to 1.0 s in 0.1 steps Indicated: Inst, 100 & 300 ms 0.1 LT set at 1 x ACB rating, In LTD set at 5 s ST set at 1.5 Ir STD set at INST Type S: Instantaneous release at 50kA 0.01 0.1 1 10 Current as multiples of N** A.24 100 M-PACT Plus * ** Trip curves* Overload & delayed short-circuit curves at Ir = 1.0 x In N=I/Ir for overload & delayed short-circuit N=I/In for instantaneous & ground M-PRO 30/40 - frame 1 & 2 100000 LT set at 1 x ACB rating, In LTD set at 30 s SC set at 6 x Ir SCD = 3 s ST set at 12 x Ir STD set at 1 s Type H: Instantaneous release at 80kA Trip curves 10000 1000 A LTD has 16 available settings 0.25...35 seconds at 7.2 x Ir Indicated: 0.2 and 30 seconds LT set at 1 x ACB rating, In LTD set at 0.2 s ST set at 1.5 Ir STD set at Inst Type S: Instantaneous release at 50kA B Time to trip in seconds (s) 100 C X SC has 8 available settings 1.5, 2, 3, 4, 6, 8, 10, 12 x Ir Indicated: 6 x Ir 10 SCD is fixed at 10 x the configured LT curve Indicated: 3 seconds ST has 8 available settings 1.5, 2, 3, 4, 6, 8, 10, 12 x Ir Indicated: 1.5 x Ir and 12 x Ir 1 Instantaneous release: Type S 50kA Type N 65kA Type H 80kA Indicated: S and H 0.1 STD adjustable: Inst to 1.0 s in 0.1 steps Indicated: Inst and 1 s 0.01 0.1 1 10 100 Current as multiples of N** A.25 M-PACT Plus * ** Earth fault protection curves* Overload & delayed short-circuit curves at Ir = 1.0 x In N=I/Ir for overload & delayed short-circuit N=I/In for instantaneous & ground M-PRO 30/40 - frame 1 & 2 Technical overview 1000 Earth fault pickup If Adjustment = 0.1 to 1.0 x In in 0.01 x In steps Pickup If set at 1 x In Cropping set at 6 Time delay set at 1 s 100 A B X Time to trip in seconds (s) C 10 Earth fault cropping C Trip Time = Time delay x C x If/I Adjustment = 1, 1.5, 2, 2.5, 3, 4, 5 & 6 Note: 1 = OFF Indicated: C = 1.5 and 6 1 Time delay has 11 settings Inst. to 1 s in steps of 0.1 s Indicated: Inst., 0.1 s and 1 s Pickup If set at 0.1 x In Time delay set at 0.1 s 0.1 Pickup If set at 0.1 x In Time delay set at inst. 0.01 0.01 0.1 1 10 Current as multiples of N** A.26 100 1000 M-PACT Plus * ** Earth fault protection curves* Overload & delayed short-circuit curves at Ir = 1.0 x In N=I/Ir for overload & delayed short-circuit N=I/In for instantaneous & ground M-PRO 30/40 - frame 1 & 2 Earth fault protection curves 1000 Earth fault pickup If Adjustment = 0.1 to 1.0 x In in 0.01 x In steps Pickup If set at 1 x In Cropping set at 6 Time delay set at 1 s 100 A B Time to trip in seconds (s) 10 C Earth fault cropping C trip Time = Time delay x C x I f/I Adjustment = 1, 1.5, 2, 2.5, 3, 4, 5 & 6 Note: 1 = OFF Indicated: C = 1.5 and 6 X 1 Time delay has 11 settings Inst. to 1 s in steps of 0.1 s Indicated: Inst., 0.1 s and 1 s Pickup If set at 0.1 x In Time delay set at 0.1 s 0.1 Pickup If set at 0.1 x In Time delay set at inst. 0.01 0.01 0.1 1 10 100 1000 Current as multiples of N** A.27 M-PACT Plus Earth fault protection curves* * ** Overload & delayed short-circuit curves at Ir = 1.0 x In N=I/Ir for overload & delayed short-circuit N=I/In for instantaneous & ground M-PRO 17 Plus/18 Plus frame 1 & frame 2 Technical overview 1000 100 C Time to trip in seconds (s) A B UEFhas h as 4 availa ble set tings UEF 4 available settings 0.4, 0.8,0.8 & 1.0 ln 0.4,0.6, 0.6, & x1.0xI n Indicated: 0.4: x0ln, & 1.0 Indi cated .40.8 x Ixn,ln,0.8 x xI nln & 1.0 x I n 10 UEFDelay Delay adjust able : UEF adjustable: <0.1, 0.1, < 0.1, 0.2, 0.4,0.2, 0.6, 0.4, 0,8 & 0.6, 1.0 0.8 Indicated: 0.1,: 0 0.4 Indi cated .1,& 1.0s 0.4 & 1 .0s & 1 .0 1 X 0.1 0.01 0.1 1 10 Current as multiples of N** A.28 100 M-PACT Plus Accessories for frame 1 & 2 Shunt trip A wide range of optional accessories have been developed that are compatible with all M-PACT Plus air circuit breakers, regardless of nominal rating or Frame size. Each one incorporates ‘easy-fit’ design features for quick installation, either in the factory or by the user on site. Motorised spring charging unit The unique motor/gearbox unit is specially designed to operate with the full range of M-PACT Plus breakers. It is easily fitted with just three bolts. In the event of circuit breaker closure, this unit will automatically recharge the spring and makes it ready for instant reclosure should the need arise. High speed recharging ensures that the springs are fully charged within approximately three seconds following a release. As an optional feature, a “springs charged” contact is available for the motor unit . Closing coil The closing coil is an easy-to-fit , clip-on unit , with simple plug-in connectors. This permits either local or remote release of the spring charged closing mechanism by electrical operation. An additional anti-pumping safety feature also ensures that the electrical closing signal must be released before further closure is attempted, and a cut-off is instigated should a closing signal be maintained. Because each coil operates within a wide voltage range, the number of individually rated coils required is drastically reduced. Undervoltage release Accessories Energisation, locally or remote, will instantaneously activate the circuit breaker mechanism, ensuring rapid disconnection of the main contacts. In addition, a series connected auxiliary switch ensures automatic isolation whenever the circuit breaker is open. Shunt trip releases also have a wide operational voltage range, and they include the same easy-fit , clip-on/plug-in connectors as the closing coil. A B C Instantaneously releases the circuit breaker trip mechanism when the supply voltage dip below the pre-set value. Simple to install, these devices have the same easy-fit features as previously described. Note: This is a ‘no-volt/no-close device. The circuit breaker cannot be closed (manually or electrically) unless the undervoltage release coil is energized. X Time delay undervoltage release Similar to the above, but this electronic device prevents nuisance tripping of the circuit breaker if circuit interruption is not desirable when supply voltage drop is only transient . Fixed time delay 3 sec ± 1 sec. Due to its principle of action the UV is suitable for emergency stop situations. A.29 M-PACT Plus Auxiliary trip combination The M-PACT Plus circuit breaker can be equipped with the following auxiliary trips or releases 1 x shunt trip + 1 x closing coil + 1 x undervoltage release or 1 time delay undervoltage release Technical overview Auxiliary switches A B C The M-PACT Plus circuit breaker is equipped with 5 NO and 3 NC auxiliary switches as standard. Maximum number of contacts is 8, for alternative configurations please contact your local customer service for availability. Lock and key types Castell: type FS1 lock with key type FK4 key, 45° clockwise rotation to trap the key, 7/8"x3/8" square spindle. Ronis: type 1104B lock with standard key, 1/4" turn rotation to trap the key, compulsory spindle size. Profalux: type B20D4Y lock with key type S1 (without cam), 1/4" turn rotation to trap the key, compulsory spindle size. Fortress: type H31/LH lock with flip cap and standard key, 45° clockwise rotation to trap the key, 7/8"x3/8" square spindle. Cassette main terminal adaptors Mechanical operation counter Easily fitted, this useful accessory may be specified for use with either manual or motor charged M-PACT Plus circuit breakers. It is clearly visible through the front panel, and the counter provides an accurate record of the cumulative number of complete breaker closing operations. Type ‘N’: 65kA rear connection shown above. Circuit breaker Key interlock facility Combinations of rear and front access connections possible for entire range. Tested and approved from 50 to 80kA. X Ready-to-fit interlocking devices such as Castell, Ronis, Profalux and Fortress, for installation between separate circuit breakers, available in kit form. This valuable safeguard ensures that a circuit breaker cannot be closed unless the dedicated key has been inserted and secured within the lock. Note: Castell, Fortress or Profalux locks and keys cannot be supplied by GE. Please order separately from your local supplier. A.30 Type ‘N’: 1600A, 65kA front access connection shown above. To simplify main busbar or cable termination, M-PACT Plus provides a full range for rear and/or front access connection. Bolt-on adaptor kits can be fitted easily to suit either horizontal or vertical connections. M-PACT Plus Cable/busbar earthing device Carriage position switch These are the main isolating contacts which are fitted to the rear terminals on the moving portion of the withdrawable unit . As part of standard inspection and maintenance procedures, cluster contacts have been designed to be easily and quickly removed and replaced using universal cluster pliers. Circuit breaker insertion interlock Accessories All M-PACT Plus circuit breakers can be fitted with an earthing device. It has a short-circuit fault capacity equal to the Icw rating of the breaker. This permits either the feeder cables or the busbar to be safety held at earthed potential and locked during system maintenance operations. Cluster contacts A B C X Available as an optional device for mounting within the base of the cassette, this switch provides six single pole changeover contacts for local or remote electrical indication of the circuit breaker status: connected, test and disconnected. The disconnected position is indicated only when minimum isolating distances between contacts on both the main and auxiliary circuits have been achieved. This option is in addition to the mechanical indicators which are fitted as standard. When installed, the carriage switch is IP2X protected and includes wiring to a terminal block located on the left-hand side of the cassette. By incorporating this optional security interlock device into a system, it prevents the inadvertent insertion of an incorrectly rated withdrawable circuit breaker into a cassette. Note: The carriage position switch is an option only suitable for withdrawable circuit breakers. A.31 M-PACT Plus Cassette interlock Automatic transfer switches (ATS) Technical overview The ATS ensures the continuity of electric supply to an installation with minimum interruption by making an automatic transfer from the normal supply to emergency source. The emergency source can be either a transformer or generator supply and the M-PACT Plus air circuit breakers are governed automatically by the transfer controller, which selects the available source. A Available for withdrawable circuit breakers only, this sophisticated interlock system secures the circuit breaker in the disconnected position by means of a Ronis or Profalux key. When the key is removed, the safety shutters are automatically locked in position, thus preventing access to the contacts and also ensuring that the racking mechanism is not operable. For lock and key details refer to key interlock facility section (page A30) Sealed door panel escutcheon B C An optional IP54 complete front door panel is available should a higher degree of protection be necessary. (Only for frame 1 & 2) X Cable interlocks Circuit breaker handling truck Specifically designed for use with the M-PACT Plus range, this dedicated handling truck is a useful accessory when faced with the task of inserting or removing the circuit breaker from its panel, or when transporting the unit should it be outside its cassette. Installers will also find it particularly valuable for top-tier mounted circuit breakers. A.32 Cable interlocking version shown above available for fixed and withdrawable circuit breakers. These units enable the direct interlocking of M-PACT Plus circuit breakers, either mounted side by side or stacked. The interlocking mechanisms are connected by a specially designed cable and provides interlocking between the breakers 1 from 2, 1 from 3 and 2 from 3 configurations Any mix of current ratings / pole configurations can be accommodated. Standard cable lengths available: 1.0, 1.6, 2.0, 2.5, 3.0, 3.5 and 4.0 meters. (Please contact our technical customer service department if longer length is required.) M-PACT Plus Interlocks Mechanical interlocks can be fitted to the following electrical systems and can link 2 and/or 3 circuit breakers. Any nominal rating, frame size, number of poles or type (fixed pattern or withdrawable) can be interlocked. Typical circuit Interlock configuration Possible combinations B1 0 I 0 Type A 1 from 2 way interlock 2 cable configuration Interlocking between 2 circuit breakers. 1 normal power supply 1 generator (emergency) supply 1 from 3 way interlock 6 cable configuration Interlocking between 3 circuit breakers. 3 power supplies (generator or transformers) feeding the same busbar but parallel operation is prevented. Circuit breaker B1 can only close if B2 is open Circuit breaker B2 can only close if B1 is open B1 0 I 0 0 B2 0 0 I 0 B3 0 0 0 I Accessories Type B B2 0 0 I Only 1 from 3 breakers can be closed A B Type C 2 from 3 way interlock 6 cable configuration Interlocking between 3 circuit breakers. 2 bus sections can be powered by a single transformer (bus coupler closed) or by both transformers (bus coupler open). Type D 1 from 3 way interlock variant 4 cable configuration (2 cables for bus coupler) Interlocking between 3 circuit breakers. 2 normal power supplies not set in parallel 1 power supply may assist the priority circuit B1 0 I 0 0 I 0 I B2 0 0 0 I I I 0 B3 0 0 I 0 0 I I Any 2 from 3 breakers can be closed Any 1 from 3 breakers can be closed 2 breakers must be closed to prevent the 3rd breaker from closing B1 0 I 0 I 0 B2 0 0 0 0 I C X B3 0 0 I I 0 Circuit breaker B1 and/or B3 can be closed only if B2 is open Circuit breaker B2 can only be closed if B1 & B3 are both open A.33 M-PACT Plus Accessories for frame 3 only Shunt trip A wide range of optional accessories are designed exclusively for frame size 3 of M-PACT Plus and can be installed, either in the factory or by the user at site. Technical overview Motorised spring charging unit The shunt trip can be easily fitted with just two screws. Energised locally or remote and will instantaneously activate the circuit breaker mechanism, ensuring rapid disconnection of the main contact . An auxiliary switch connected in series ensures automatic isolation whenever the circuit breaker is open. A Undervoltage release B C X The motor/gearbox unit is easily fitted with just three screws bolts. In the event of circuit breaker closure, this unit will automatically recharge the spring and make it ready for instant reclosure should the need arise (other charging methods on request). Speed recharging ensures that the springs are fully charged within approximately 9 seconds after motor starts. As an optional feature “breaker ready for closure” contact is available. Circuit breaker closing coil The closing coil is fitted with just two screws. This permits either local or remote release of the spring charged closing mechanism by electrical operation. A.34 The undervoltage release is simple and easy to install. The unit is suitable for remote tripping, voltage monitoring and for interlocking purposes. The circuit breaker cannot be closed manually or electrically if the release is denergised. The undervoltage release is designed for continuous operation. Due to its principle of action the undervoltage release is suitable for EMERGENCY STOP situations. Time delayed undervoltage release (delay time tv = 1.5 ± 0.5s) is available by connecting to the standard UVR 220V DC an additional electronic delay circuit . Circuit is housed in separate CK1 steel enclosure. Auxiliary trip combination Auxiliary trip combination is available with 2 x shunt trip + 1 x closing coil + 1 x undervoltage release or 1 time delay undervoltage release. M-PACT Plus Auxiliary switches Lock and key types The M-PACT Plus Frame 3 circuit breaker is equipped with 4NO and 6NC auxiliary switches as standard. Castell: type FS1 lock with key type FK4 key, 45° clockwise rotation to trap the key, 7/8"x3/8" square spindle. Ronis: type 1104B lock with standard key, 1/4" turn rotation to trap the key, compulsory spindle size. Mechanical operation counter Carriage position switch Accessories Easily fitted with two screws may be specified for use with either manual or motor charged M-PACT Plus Frame 3 circuit breakers. It is clearly visible through the front panel, and the counter provides an accurate record of the cumulative number of complete breaker charging operations. Key interlock facility A B Available as an optional device for mounting within the base of the cassette. This switches are provided for monitoring the positions connected, test and disconnected of the circuit breaker in the cradle and are suitable for electrical interlocking purposes. Max four auxiliary switches with 2NC and 2NO each. C X Note: the carriage position switch is an option only suitable for withdrawable circuit breakers. Cable interlock - type A Mounting kit for mechanical interlock of two M-PACT Plus Frame 3 circuit breakers for fixed installation or withdrawable pattern without electrical interlock: (provided supplementary), installation alternatively side-by-side or stacked. One 2.3 m cable is provided in standard with each frame 3 interlock kit . Typical circuit Interlock configuration Type A Ready-to-fit interlocking devices such as Ronis or Castell for installation into circuit breakers, available in kit form. This valuable safeguard ensures that a circuit breaker cannot be closed unless the dedicated key has been inserted and secured within the lock. Interlocking between 2 breakers. 1 normal power supply 1 emergency supply Possible combinations B1 0 0 I B2 0 I 0 Circuit breaker B1 can only close if B2 is open Circuit breaker B2 can only close if B1 is open Note: Castell lock and key are not supplied by GE. Please order separately from your local supplier. A.35 M-PACT Plus Accessories performance data Operating voltage (V) AC DC Auxiliary and carriage swtich 250 Frame 1 & 2 125 250 Technical overview 230 Auxiliary contacts Frame 3 Carriage switch Frame 3 Frame 1 & 2 220 110 60 24 400 220 - 250 110 - 127 220 - 240 Motor operator 110 - 120 Frame 3 110 220 - 250 110 - 127 42 - 48 24 - 30 220 - 240 125 110 - 120 60 48 Operating range - 0.85 to 1.1 times rated voltage Frame 1 & 2 Frame 3 A B Frame 1 & 2 110 - 120 60 48 42 24 220 - 250 110 - 130 220 125 110 - 120 60 48 24 220 - 250 110 - 130 40 - 48 24 - 30 400 410 0.85 to 1.1 times rated voltage C Frame 3 X Frame 1 & 2 Instantanious undervoltage release Frame 3 Auxiliary power unit Frame 1 , 2 & 3 A.36 110 - 120 60 48 42 24 380 - 440 220 - 250 110 - 130 240 220 - 230 120 / 125 110 60 48 42 24 95 - 265 350 350 350 350 350 350 0.70 to 1.1 times rated voltage 220 - 240 Shunt trip 350 440 500 440 420 410 300 24 220 - 250 110 - 130 40 - 48 24 - 30 220 - 240 Closing coil 500 450 42 220 - 250 110 - 130 Power consumption VA max. Watt max. 185 185 185 185 185 185 410 350 220 125 110 - 120 60 48 24 110 - 130 42 - 48 24 - 30 240 220 - 230 120 / 125 110 60 48 42 24 24 - 264 0.85 to 1.1 times rated voltage 350 350 350 350 350 holds 0.85 to 1.1 x rated voltage release 0.7 to 0.35 x rated voltage - 185 185 185 185 185 185 400 80 mA 90 mA 160 mA 190 mA 330 mA 420 mA 490 mA 910 mA - 80 mA 90 mA 160 mA 190 mA 330 mA 420 mA 490 mA 910 mA 12 Rating (Amps resistive) 10 5 0.25 10 1 2 4 10 10 6 - M-PACT Plus B.2 B.4 B.6 B.8 B.10 B.12 B.14 B.15 B.16 B.17 B.18 B.20 Air circuit breaker - type S - 50kA - Non-automatic Air circuit breaker - type S - 50kA - Automatic Air circuit breaker - type N - 65kA - Non-automatic Air circuit breaker - type N - 65kA - Automatic Air circuit breaker - type H - 80kA - Non-automatic Air circuit breaker - type H - 80kA - Automatic Air circuit breaker - type C - 100kA - Non-automatic/ Automatic M-PRO protection relay Frame 1 & 2 - electrical accessories Frame 3 - electrical accessories Mechanical accessories Spare parts Technical overview A Order codes B Wiring diagrams / Dimensional drawings C Numerical index X B.1 M-PACT Plus Air circuit breaker - type S - 50kA - Non-automatic Frame 1 & 2 Basic circuit breaker manually operated, non automatic (switch only, no protection unit option available), 5 NO and 3 NC auxiliary switches. Withdrawable pattern - basic circuit breaker and cassette with flat copper terminals, rear connected. Fixed Pattern - basic circuit breaker with rear horizontal terminals. Withdrawable and fixed pattern Frame size Rating (A) 1 400 Order codes 1 800 1 1000 1 1250 1 1600 1 2000 1 B 2500 2 C 2000 2 2500 2 X 3200 2 4000 Withdrawable Position of the neutral 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 630 1 A Poles Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Fixed pattern Cat. No. Ref. No. Cat. No. Ref. No. MS31W04 MS4L1W04 MS4R1W04 MS31W06 MS4L1W06 MS4R1W06 MS31W08 MS4L1W08 MS4R1W08 MS31W10 MS4L1W10 MS4R1W10 MS31W12 MS4L1W12 MS4R1W12 MS31W16 MS4L1W16 MS4R1W16 MS31W20 MS4L1W20 MS4R1W20 MS31W25 MS4L1W25 MS4R1W25 MS32W20 MS4L2W20 MS4R2W20 MS32W25 MS4L2W25 MS4R2W25 MS32W32 MS4L2W32 MS4R2W32 MS32W40 MS4L2W40 MS4R2W40 405103 405102 405316 405105 405104 405318 405107 405106 405320 405109 405108 405322 405111 405110 405324 405113 405112 405326 405115 405114 405328 405117 405116 405330 405119 405118 405332 405121 405120 405334 405123 405122 405336 405125 405124 405338 MS31F04 MS4L1F04 MS4R1F04 MS31F06 MS4L1F06 MS4R1F06 MS31F08 MS4L1F08 MS4R1F08 MS31F10 MS4L1F10 MS4R1F10 MS31F12 MS4L1F12 MS4R1F12 MS31F16 MS4L1F16 MS4R1F16 MS31F20 MS4L1F20 MS4R1F20 MS31F25 MS4L1F25 MS4R1F25 MS32F20 MS4L2F20 MS4R2F20 MS32F25 MS4L2F25 MS4R2F25 MS32F32 MS4L2F32 MS4R2F32 MS32F40 MS4L2F40 MS4R2F40 405133 405132 405366 405135 405134 405368 405137 405136 405370 405139 405138 405372 405141 405140 405374 405143 405142 405376 405145 405144 405378 405147 405146 405381 405149 405148 405384 405151 405150 405387 405153 405152 405391 405155 405154 405393 Rear connections Frame size Rating (A) Poles 1 400 to 1600 1 400 to 1600 1 2000 & 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 3 4 Withdrawable or cassettes Fixed pattern Cat. No. Ref. No. Type Cat. No. Ref. No. Type RT1HOR RT1HOR RT1VER RT1VER RT1UNI RT1UNI RT2UNI RT2UNI N/A N/A 403680 403680 403681 403681 405600 405600 405601 405601 N/A N/A Horizontal Horizontal Vertical Vertical Universal Universal Universal Universal Vertical Vertical RT1SVFIX RT1SVFIX RT1SNVFIX RT1SNVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX 405603 405603 405609 405609 405621 405621 405621 405621 Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Rear Connections specified in multiples of 3, 4, 6 or 8 dependant on 3 or 4 pole configuration - top and / or bottom connections. Front access connections Withdrawable TOP connections BOTTOM connections B.2 Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 FA31WS16T FA41WS16T FA31WS25T FA41WS25T FA32WS32T FA42WS32T FA32WS40T FA42WS40T 405921 405922 405923 405924 405925 405926 405927 405928 FA31WS16B FA41WS16B FA31WS25B FA41WS25B FA32WS32B FA42WS32B FA32WS40B FA42WS40B 406021 406022 406023 406024 406025 406026 406027 406028 M-PACT Plus Front access connections Fixed pattern TOP connections BOTTOM connections Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 FA31FS16T FA41FS16T FA31FS25T FA41FS25T FA32FS32T FA42FS32T FA32FS40T FA42FS40T 405933 405934 405935 405936 405937 405938 405939 405940 FA31FS16B FA41FS16B FA31FS25B FA41FS25B FA32FS32B FA42FS32B FA32FS40B FA42FS40B 406033 406034 406035 406036 406037 406038 406039 406040 Cassette only Frame size Rating (A) Poles Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 MS31C16 MS41C16 MS31C25 MS41C25 MS32C32 MS42C32 MS32C40 MS42C40 405341 405340 405343 405342 405355 405354 405365 405364 Moving portion only Basic circuit breaker manually operated, non automatic (switch only, no protection unit option available), 5 NO and 3 NC auxiliary switches and cluster contacts. Frame size Rating (A) Poles 1 400 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 1 1 1 1 1 1 1 2 2 2 2 630 800 1000 1250 1600 2000 2500 2000 2500 3200 4000 Position of the neutral Cat. No. Ref. No. Left Right MS31M04 MS4L1M04 MS4R1M04 MS31M06 MS4L1M06 MS4R1M06 MS31M08 MS4L1M08 MS4R1M08 MS31M10 MS4L1M10 MS4R1M10 MS31M12 MS4L1M12 MS4R1M12 MS31M16 MS4L1M16 MS4R1M16 MS31M20 MS4L1M20 MS4R1M20 MS31M25 MS4L1M25 MS4R1M25 MS32M20 MS4L2M20 MS4R2M20 MS32M25 MS4L2M25 MS4R2M25 MS32M32 MS4L2M32 MS4R2M32 MS32M40 MS4L2M40 MS4R2M40 405803 405804 405524 405805 405806 405526 405807 405808 405528 405809 405810 405542 405811 405812 405548 405813 405814 405582 405815 405816 405584 405817 405818 405586 405819 405820 405588 405821 405822 405590 405823 405824 405592 405825 405826 405594 Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right ACB’s - type S Basic cassette with flat copper terminals rear connected, integral racking handle, safety shutters and lockable safety features. A B C X Earthing device Frame size Rating (A) Poles Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 3200 to 4000 3 4 3 4 3 4 EDF13P16 EDF14P16 EDF13P25 EDF14P25 EDF23P40 EDF24P40 405661 405660 405663 405662 405665 405664 B.3 M-PACT Plus Air circuit breaker - type S - 50kA - Automatic Frame 1 & 2 (Please select trip unit type in page B.15) Basic circuit breaker manually operated, automatic (must be fitted with an M-Pro Protection Unit as listed on page B15), 5 NO and 3 NC auxiliary switches. Withdrawable pattern - basic circuit breaker and cassette with flat copper terminals, rear connected. Fixed Pattern - basic circuit breaker with rear horizontal terminals. Withdrawable and fixed pattern Frame size Rating (A) 1 400 Order codes 1 800 1 1000 1 1250 1 1600 1 2000 1 B 2500 2 2000 2 C 2500 2 X 3200 2 4000 Withdrawable Position of the neutral 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 630 1 A Poles Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Fixed pattern Cat. No. Ref. No. Cat. No. Ref. No. MS31W04-A MS4L1W04-A MS4R1W04-A MS31W06-A MS4L1W06-A MS4R1W06-A MS31W08-A MS4L1W08-A MS4R1W08-A MS31W10-A MS4L1W10-A MS4R1W10-A MS31W12-A MS4L1W12-A MS4R1W12-A MS31W16-A MS4L1W16-A MS4R1W16-A MS31W20-A MS4L1W20-A MS4R1W20-A MS31W25-A MS4L1W25-A MS4R1W25-A MS32W20-A MS4L2W20-A MS4R2W20-A MS32W25-A MS4L2W25-A MS4R2W25-A MS32W32-A MS4L2W32-A MS4R2W32-A MS32W40-A MS4L2W40-A MS4R2W40-A 406177 406178 406260 406179 406180 406262 406181 406182 406264 406183 406184 406266 406185 406186 406268 406187 406188 406270 406189 406190 406272 406191 406192 406274 406193 406194 406276 406195 406196 406278 406197 406198 406280 406199 406200 406282 MS31F04-A MS4L1F04-A MS4R1F04-A MS31F06-A MS4L1F06-A MS4R1F06-A MS31F08-A MS4L1F08-A MS4R1F08-A MS31F10-A MS4L1F10-A MS4R1F10-A MS31F12-A MS4L1F12-A MS4R1F12-A MS31F16-A MS4L1F16-A MS4R1F16-A MS31F20-A MS4L1F20-A MS4R1F20-A MS31F25-A MS4L1F25-A MS4R1F25-A MS32F20-A MS4L2F20-A MS4R2F20-A MS32F25-A MS4L2F25-A MS4R2F25-A MS32F32-A MS4L2F32-A MS4R2F32-A MS32F40-A MS4L2F40-A MS4R2F40-A 405217 405216 405186 405219 405218 405278 405239 405238 405296 405241 405240 405298 405247 405246 405390 405249 405248 405392 405251 405250 405404 405253 405252 405682 405255 405254 405712 405269 405268 405722 405271 405270 405748 405277 405276 405786 Rear connections Fram e size Rating (A) Poles 1 400 to 1600 1 400 to 1600 1 2000 & 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 3 4 Withdrawable or cassettes Fixed pattern Cat. No. Ref. No. Type Cat. No. Ref. No. Type RT1HOR RT1HOR RT1VER RT1VER RT1UNI RT1UNI RT2UNI RT2UNI N/A N/A 403680 403680 403681 403681 405600 405600 405601 405601 N/A N/A Horizontal Horizontal Vertical Vertical Universal Universal Universal Universal Vertical Vertical RT1SVFIX RT1SVFIX RT1SNVFIX RT1SNVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX 405603 405603 405609 405609 405621 405621 405621 405621 Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Rear Connections specified in multiples of 3, 4, 6 or 8 dependant on 3 or 4 pole configuration - top and / or bottom connections. Front access connections Withdrawable TOP connections BOTTOM connections B.4 Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 FA31WS16T FA41WS16T FA31WS25T FA41WS25T FA32WS32T FA42WS32T FA32WS40T FA42WS40T 405921 405922 405923 405924 405925 405926 405927 405928 FA31WS16B FA41WS16B FA31WS25B FA41WS25B FA32WS32B FA42WS32B FA32WS40B FA42WS40B 406021 406022 406023 406024 406025 406026 406027 406028 M-PACT Plus Front access connections Fixed pattern TOP connections BOTTOM connections Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 FA31FS16T FA41FS16T FA31FS25T FA41FS25T FA32FS32T FA42FS32T FA32FS40T FA42FS40T 405933 405934 405935 405936 405937 405938 405939 405940 FA31FS16B FA41FS16B FA31FS25B FA41FS25B FA32FS32B FA42FS32B FA32FS40B FA42FS40B 406033 406034 406035 406036 406037 406038 406039 406040 Cassette only Frame size Rating (A) Poles Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 MS31C16 MS41C16 MS31C25 MS41C25 MS32C32 MS42C32 MS32C40 MS42C40 405341 405340 405343 405342 405355 405354 405365 405364 Moving portion only Basic circuit breaker manually operated, automatic (must be fitted with an M-Pro Protection Unit as listed on page B15), 5 NO and 3 NC auxiliary switches and cluster contacts. Frame size Rating (A) Poles 1 400 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 1 1 1 1 1 1 1 2 2 2 2 630 800 1000 1250 1600 2000 2500 2000 2500 3200 4000 Position of the neutral Cat. No. Ref. No. Left Right MS31M04-A MS4L1M04-A MS4R1M04-A MS31M06-A MS4L1M06-A MS4R1M06-A MS31M08-A MS4L1M08-A MS4R1M08-A MS31M10-A MS4L1M10-A MS4R1M10-A MS31M12-A MS4L1M12-A MS4R1M12-A MS31M16-A MS4L1M16-A MS4R1M16-A MS31M20-A MS4L1M20-A MS4R1M20-A MS31M25-A MS4L1M25-A MS4R1M25-A MS32M20-A MS4L2M20-A MS4R2M20-A MS32M25-A MS4L2M25-A MS4R2M25-A MS32M32-A MS4L2M32-A MS4R2M32-A MS32M40-A MS4L2M40-A MS4R2M40-A 405905 405906 406162 405907 405908 406164 405909 405910 406166 405911 405912 406168 405913 405914 406170 405915 405916 406172 405995 405918 406174 405919 405920 406176 405929 405930 406208 405931 405932 406214 405941 405942 406216 405943 405944 406218 Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right ACB’s - type S Basic cassette with flat copper terminals rear connected, integral racking handle, safety shutters and lockable safety features. A B C X Earthing device Frame size Rating (A) Poles Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 3200 to 4000 3 4 3 4 3 4 EDF13P16 EDF14P16 EDF13P25 EDF14P25 EDF23P40 EDF24P40 405661 405660 405663 405662 405665 405664 B.5 M-PACT Plus Air circuit breaker - type N - 65kA - Non-automatic Frame 1 & 2 Basic circuit breaker manually operated, non automatic (switch only, no protection unit option available), 5 NO and 3 NC auxiliary switches. Withdrawable pattern - basic circuit breaker and cassette with flat copper terminals, rear connected. Fixed Pattern - basic circuit breaker with rear horizontal terminals. Withdrawable and fixed pattern Frame size Rating (A) 1 400 Order codes 1 800 1 1000 1 1250 1 1600 1 2000 1 B 2500 2 C 2000 2 2500 2 X 3200 2 4000 Withdrawable Position of the neutral 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 630 1 A Poles Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Fixed pattern Cat. No. Ref. No. Cat. No. Ref. No. MN31W04 MN4L1W04 MN4R1W04 MN31W06 MN4L1W06 MN4R1W06 MN31W08 MN4L1W08 MN4R1W08 MN31W10 MN4L1W10 MN4R1W10 MN31W12 MN4L1W12 MN4R1W12 MN31W16 MN4L1W16 MN4R1W16 MN31W20 MN4L1W20 MN4R1W20 MN31W25 MN4L1W25 MN4R1W25 MN32W20 MN4L2W20 MN4R2W20 MN32W25 MN4L2W25 MN4R2W25 MN32W32 MN4L2W32 MN4R2W32 MN32W40 MN4L2W40 MN4R2W40 405163 405162 405430 405165 405164 405432 405167 405166 405434 405169 405168 405436 405171 405170 405438 405173 405172 405456 405175 405174 405458 405177 405176 405460 405179 405178 405462 405181 405180 405464 405183 405182 405466 405185 405184 405468 MN31F04 MN4L1F04 MN4R1F04 MN31F06 MN4L1F06 MN4R1F06 MN31F08 MN4L1F08 MN4R1F08 MN31F10 MN4L1F10 MN4R1F10 MN31F12 MN4L1F12 MN4R1F12 MN31F16 MN4L1F16 MN4R1F16 MN31F20 MN4L1F20 MN4R1F20 MN31F25 MN4L1F25 MN4R1F25 MN32F20 MN4L2F20 MN4R2F20 MN32F25 MN4L2F25 MN4R2F25 MN32F32 MN4L2F32 MN4R2F32 MN32F40 MN4L2F40 MN4R2F40 405193 405192 405470 405195 405194 405472 405197 405196 405474 405199 405198 405476 405201 405200 405478 405203 405202 405480 405205 405204 405482 405207 405206 405484 405209 405208 405486 405211 405210 405488 405213 405212 405490 405215 405214 405492 Rear connections Frame size Rating (A) Poles 1 400 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 Withdrawable or cassettes Fixed pattern Cat. No. Ref. No. Type Cat. No. Ref. No. Type RT1UNI RT1UNI RT2UNI RT2UNI N/A N/A 405600 405600 405601 405601 N/A N/A Universal Universal Universal Universal Vertical Vertical RT1SNVFIX RT1SNVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX 405609 405609 405621 405621 405621 405621 Vertical Vertical Vertical Vertical Vertical Vertical Rear Connections specified in multiples of 3, 4, 6 or 8 dependant on 3 or 4 pole configuration - top and / or bottom connections. Front access connections Withdrawable TOP connections BOTTOM connections B.6 Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 FA31WN16T FA41WN16T FA31WN25T FA41WN25T FA32WN32T FA42WN32T FA32WN40T FA42WN40T 405945 405946 405947 405948 405949 405950 405951 405952 FA31WN16B FA41WN16B FA31WN25B FA41WN25B FA32WN32B FA42WN32B FA32WN40B FA42WN40B 406045 406046 406047 406048 406049 406050 406051 406052 M-PACT Plus Front access connections Fixed pattern TOP connections BOTTOM connections Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 FA31FN16T FA41FN16T FA31FN25T FA41FN25T FA32FN32T FA42FN32T FA32FN40T FA42FN40T 405957 405958 405959 405960 405961 405962 405963 405964 FA31FN16B FA41FN16B FA31FN25B FA41FN25B FA32FN32B FA42FN32B FA32FN40B FA42FN40B 405557 405558 405559 405560 405561 405562 405563 405564 Cassette only Frame size Rating (A) Poles Cat. No. Ref. No. 1 400 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 MN31C25 MN41C25 MN32C32 MN42C32 MN32C40 MN42C40 405345 405344 405347 405346 405349 405348 ACB’s - type N Basic cassette with flat copper terminals rear connected, integral racking handle, safety shutters and lockable safety features. Moving portion only Basic circuit breaker manually operated, non automatic (switch only, no protection unit option available), 5 NO and 3 NC auxiliary switches and cluster contacts. Frame size Rating (A) Poles 1 400 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 1 1 1 1 1 1 1 2 2 2 2 630 800 1000 1250 1600 2000 2500 2000 2500 3200 4000 Position of the neutral Cat. No. Ref. No. Left Right MN31M04 MN4L1M04 MN4R1M04 MN31M06 MN4L1M06 MN4R1M06 MN31M08 MN4L1M08 MN4R1M08 MN31M10 MN4L1M10 MN4R1M10 MN31M12 MN4L1M12 MN4R1M12 MN31M16 MN4L1M16 MN4R1M16 MN31M20 MN4L1M20 MN4R1M20 MN31M25 MN4L1M25 MN4R1M25 MN32M20 MN4L2M20 MN4R2M20 MN32M25 MN4L2M25 MN4R2M25 MN32M32 MN4L2M32 MN4R2M32 MN32M40 MN4L2M40 MN4R2M40 405833 405834 405596 405835 405836 405598 405837 405838 405602 405839 405840 405604 405841 405842 405622 405843 405844 405624 405845 405846 405626 405847 405848 405628 405849 405850 405630 405851 405852 405632 405853 405854 405634 405855 405856 405636 Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right A B C X Earthing device Frame size Rating (A) Poles Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 3200 to 4000 3 4 3 4 3 4 EDF13P16 EDF14P16 EDF13P25 EDF14P25 EDF23P40 EDF24P40 405661 405660 405663 405662 405665 405664 B.7 M-PACT Plus Air circuit breaker - type N - 65kA - Automatic Frame 1 & 2 (Please select trip unit type in page B.15) Basic circuit breaker manually operated, automatic (must be fitted with an M-Pro Protection Unit as listed on page B15), 5 NO and 3 NC auxiliary switches. Withdrawable pattern - basic circuit breaker and cassette with flat copper terminals, rear connected. Fixed Pattern - basic circuit breaker with rear horizontal terminals. Withdrawable and fixed pattern Frame size Rating (A) 1 400 Order codes 1 800 1 1000 1 1250 1 1600 1 B 2000 1 2500 2 C 2000 2 2500 2 X 3200 2 4000 Withdrawable Position of the neutral 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 630 1 A Poles Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Fixed pattern Cat. No. Ref. No. Cat. No. Ref. No. MN31W04-A MN4L1W04-A MN4R1W04-A MN31W06-A MN4L1W06-A MN4R1W06-A MN31W08-A MN4L1W08-A MN4R1W08-A MN31W10-A MN4L1W10-A MN4R1W10-A MN31W12-A MN4L1W12-A MN4R1W12-A MN31W16-A MN4L1W16-A MN4R1W16-A MN31W20-A MN4L1W20-A MN4R1W20-A MN31W25-A MN4L1W25-A MN4R1W25-A MN32W20-A MN4L2W20-A MN4R2W20-A MN32W25-A MN4L2W25-A MN4R2W25-A MN32W32-A MN4L2W32-A MN4R2W32-A MN32W40-A MN4L2W40-A MN4R2W40-A 405351 405350 405832 405353 405352 405864 405361 405360 405866 405363 405362 405882 405412 405410 405902 405415 405414 405904 405417 405416 405994 405419 405418 405996 405425 405424 406020 405445 405444 406032 405453 405452 406042 405455 405454 406044 MN31F04-A MN4L1F04-A MN4R1F04-A MN31F06-A MN4L1F06-A MN4R1F06-A MN31F08-A MN4L1F08-A MN4R1F08-A MN31F10-A MN4L1F10-A MN4R1F10-A MN31F12-A MN4L1F12-A MN4R1F12-A MN31F16-A MN4L1F16-A MN4R1F16-A MN31F20-A MN4L1F20-A MN4R1F20-A MN31F25-A MN4L1F25-A MN4R1F25-A MN32F20-A MN4L2F20-A MN4R2F20-A MN32F25-A MN4L2F25-A MN4R2F25-A MN32F32-A MN4L2F32-A MN4R2F32-A MN32F40-A MN4L2F40-A MN4R2F40-A 405657 405656 406054 405659 405658 406094 405681 405680 406096 405721 405720 406098 405731 405730 406114 405733 405732 406116 405735 405734 406118 405737 405736 406120 405779 405778 406122 405781 405780 406124 405783 405782 406126 405785 405784 406128 Rear connections Frame size Rating (A) Poles 1 400 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 Withdrawable or cassettes Fixed pattern Cat. No. Ref. No. Type Cat. No. Ref. No. Type RT1UNI RT1UNI RT2UNI RT2UNI N/A N/A 405600 405600 405601 405601 N/A N/A Universal Universal Universal Universal Vertical Vertical RT1SNVFIX RT1SNVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX 405609 405609 405621 405621 405621 405621 Vertical Vertical Vertical Vertical Vertical Vertical Rear Connections specified in multiples of 3, 4, 6 or 8 dependant on 3 or 4 pole configuration - top and / or bottom connections. Front access connections Withdrawable TOP connections BOTTOM connections B.8 Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 FA31WN16T FA41WN16T FA31WN25T FA41WN25T FA32WN32T FA42WN32T FA32WN40T FA42WN40T 405945 405946 405947 405948 405949 405950 405951 405952 FA31WN16B FA41WN16B FA31WN25B FA41WN25B FA32WN32B FA42WN32B FA32WN40B FA42WN40B 406045 406046 406047 406048 406049 406050 406051 406052 M-PACT Plus Front access connections Fixed pattern TOP connections BOTTOM connections Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 3 4 FA31FN16T FA41FN16T FA31FN25T FA41FN25T FA32FN32T FA42FN32T FA32FN40T FA42FN40T 405957 405958 405959 405960 405961 405962 405963 405964 FA31FN16B FA41FN16B FA31FN25B FA41FN25B FA32FN32B FA42FN32B FA32FN40B FA42FN40B 405557 405558 405559 405560 405561 405562 405563 405564 Cassette only Basic cassette with flat copper terminals rear connected, integral racking handle, safety shutters and lockable safety features. Rating (A) Poles Cat. No. Ref. No. 1 400 to 2500 2 800 to 3200 2 4000 3 4 3 4 3 4 MN31C25 MN41C25 MN32C32 MN42C32 MN32C40 MN42C40 405345 405344 405347 405346 405349 405348 ACB’s - type N Frame size Moving portion only Basic circuit breaker manually operated, automatic (must be fitted with an M-Pro Protection Unit as listed on page B15), 5 NO and 3 NC auxiliary switches and cluster contacts. Frame size Rating (A) Poles 1 400 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 1 1 1 1 1 1 1 2 2 2 2 630 800 1000 1250 1600 2000 2500 2000 2500 3200 4000 Position of the neutral Cat. No. Ref. No. Left Right MN31M04-A MN4L1M04-A MN4R1M04-A MN31M06-A MN4L1M06-A MN4R1M06-A MN31M08-A MN4L1M08-A MN4R1M08-A MN31M10-A MN4L1M10-A MN4R1M10-A MN31M12-A MN4L1M12-A MN4R1M12-A MN31M16-A MN4L1M16-A MN4R1M16-A MN31M20-A MN4L1M20-A MN4R1M20-A MN31M25-A MN4L1M25-A MN4R1M25-A MN32M20-A MN4L2M20-A MN4R2M20-A MN32M25-A MN4L2M25-A MN4R2M25-A MN32M32-A MN4L2M32-A MN4R2M32-A MN32M40-A MN4L2M40-A MN4R2M40-A 405953 405954 406220 405955 405956 406222 405965 405966 406224 405967 405968 406226 405969 405970 406228 405971 405972 406230 405977 405978 406232 405979 405980 406234 405981 405982 406236 405983 405984 406238 405989 405990 406240 405991 405992 406242 Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right A B C X Earthing device Frame size Rating (A) Poles Cat. No. Ref. No. 1 400 to 1600 1 2000 to 2500 2 3200 to 4000 3 4 3 4 3 4 EDF13P16 EDF14P16 EDF13P25 EDF14P25 EDF23P40 EDF24P40 405661 405660 405663 405662 405665 405664 B.9 M-PACT Plus Air circuit breaker - type H - 80kA - Non-automatic Frame 2 Basic circuit breaker manually operated, non automatic (switch only, no protection unit option available), 5 NO and 3 NC auxiliary switches. Withdrawable pattern - basic circuit breaker and cassette with flat copper terminals, rear connected. Fixed Pattern - basic circuit breaker with rear horizontal terminals. Withdrawable and fixed pattern Frame size Rating (A) 2 800 Order codes 2 1250 2 1600 2 2000 2 2 3200 2 B C 2500 4000 Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Fixed pattern Cat. No. Ref. No. Cat. No. Ref. No. MH32W08 MH4L2W08 MH4R2W08 MH32W10 MH4L2W10 MH4R2W10 MH32W12 MH4L2W12 MH4R2W12 MH32W16 MH4L2W16 MH4R2W16 MH32W20 MH4L2W20 MH4R2W20 MH32W25 MH4L2W25 MH4R2W25 MH32W32 MH4L2W32 MH4R2W32 MH32W40 MH4L2W40 MH4R2W40 405227 405226 405494 405229 405228 405496 405231 405230 405498 405233 405232 405500 405235 405234 405502 405237 405236 405504 405243 405242 405506 405245 405244 405508 MH32F08 MH4L2F08 MH4R2F08 MH32F10 MH4L2F10 MH4R2F10 MH32F12 MH4L2F12 MH4R2F12 MH32F16 MH4L2F16 MH4R2F16 MH32F20 MH4L2F20 MH4R2F20 MH32F25 MH4L2F25 MH4R2F25 MH32F32 MH4L2F32 MH4R2F32 MH32F40 MH4L2F40 MH4R2F40 405257 405256 405509 405259 405258 405510 405261 405260 405512 405263 405262 405514 405265 405264 405516 405267 405266 405518 405273 405272 405520 405275 405274 405522 Rear connections Frame size Rating (A) Poles X Withdrawable Position of the neutral 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 1000 2 A Poles 2 800 to 3200 2 4000 3 4 3 4 Withdrawable or cassettes Fixed pattern Cat. No. Ref. No. Type Cat. No. Ref. No. Type RT2UNI RT2UNI N/A N/A 405601 405601 N/A N/A Universal Universal Vertical Vertical RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX 405621 405621 405621 405621 Vertical Vertical Vertical Vertical Rear Connections specified in multiples of 3, 4, 6 or 8 dependant on 3 or 4 pole configuration - top and / or bottom connections. Front access connections Withdrawable TOP connections BOTTOM connections Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 2 800 to 3200 2 4000 3 4 3 4 FA32WH32T FA42WH32T FA32WH40T FA42WH40T 405973 405974 405975 405976 FA32WH32B FA42WH32B FA32WH40B FA42WH40B 405553 405554 405555 405556 Front access connections Fixed pattern TOP connections BOTTOM connections B.10 Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 2 800 to 3200 2 4000 3 4 3 4 FA32FH32T FA42FH32T FA32FH40T FA42FH40T 405985 405986 405987 405988 FA32FH32B FA42FH32B FA32FH40B FA42FH40B 405565 405566 405567 405568 M-PACT Plus Cassette only Basic cassette with flat copper terminals rear connected (800-3200A), integral racking handle, safety shutters and lockable safety features. 4000A units fitted with rear vertical terminals as standard (not to be removed). Frame size Rating (A) Poles Cat. No. Ref. No. 2 800 to 3200 2 4000 3 4 3 4 MH32C32 MH42C32 MH32C40 MH42C40 405357 405356 405359 405358 Basic circuit breaker manually operated, non automatic (switch only, no protection unit option available), 5 NO and 3 NC auxiliary switches and cluster contacts. Frame size Rating (A) Poles 2 800 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 2 2 2 2 2 2 2 1000 1250 1600 2000 2500 3200 4000 Position of the neutral Cat. No. Ref. No. Left Right MH32M08 MH4L2M08 MH4R2M08 MH32M10 MH4L2M10 MH4R2M10 MH32M12 MH4L2M12 MH4R2M12 MH32M16 MH4L2M16 MH4R2M16 MH32M20 MH4L2M20 MH4R2M20 MH32M25 MH4L2M25 MH4R2M25 MH32M32 MH4L2M32 MH4R2M32 MH32M40 MH4L2M40 MH4R2M40 405867 405868 405638 405869 405870 405640 405871 405872 405642 405873 405874 405644 405875 405876 405646 405877 405878 405648 405883 405884 405650 405885 405886 405652 Left Right Left Right Left Right Left Right Left Right Left Right Left Right ACB’s - type H Moving portion only A B C X Earthing device Frame size Rating (A) Poles Cat. No. Ref. No. 2 800 to 4000 3 4 EDF23P40 EDF24P40 405665 405664 B.11 M-PACT Plus Air circuit breaker - type H - 80kA - Automatic Frame 2 (Please select trip unit type in page B.15) Basic circuit breaker manually operated, automatic (must be fitted with an M-Pro Protection Unit as listed on page B15), 5 NO and 3 NC auxiliary switches. Withdrawable pattern - basic circuit breaker and cassette with flat copper terminals, rear connected. Fixed Pattern - basic circuit breaker with rear horizontal terminals. Withdrawable and fixed pattern Frame size Rating (A) 2 800 Order codes 2 1250 2 1600 2 2000 2 2500 2 B C X 3200 2 4000 Withdrawable Position of the neutral 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 1000 2 A Poles Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Fixed pattern Cat. No. Ref. No. Cat. No. Ref. No. MH32W08-A MH4L2W08-A MH4R2W08-A MH32W10-A MH4L2W10-A MH4R2W10-A MH32W12-A MH4L2W12-A MH4R2W12-A MH32W16-A MH4L2W16-A MH4R2W16-A MH32W20-A MH4L2W20-A MH4R2W20-A MH32W25-A MH4L2W25-A MH4R2W25-A MH32W32-A MH4L2W32-A MH4R2W32-A MH32W40-A MH4L2W40-A MH4R2W40-A 405797 405796 406130 405799 405802 406134 405801 405798 406132 405829 405828 406136 405831 405830 406138 405859 405858 406140 405861 405860 406142 405863 405862 406144 MH32F08-A MH4L2F08-A MH4R2F08-A MH32F10-A MH4L2F10-A MH4R2F10-A MH32F12-A MH4L2F12-A MH4R2F12-A MH32F16-A MH4L2F16-A MH4R2F16-A MH32F20-A MH4L2F20-A MH4R2F20-A MH32F25-A MH4L2F25-A MH4R2F25-A MH32F32-A MH4L2F32-A MH4R2F32-A MH32F40-A MH4L2F40-A MH4R2F40-A 405881 405880 406146 405889 405888 406148 405891 405890 406150 405893 405892 406152 405895 405894 406154 405897 405896 406156 405899 405898 406158 405901 405900 406160 Rear connections Frame size Rating (A) Poles 2 800 to 3200 2 4000 3 4 3 4 Withdrawable or cassettes Cat. No. Ref. No. Type RT2UNI RT2UNI N/A N/A 405601 405601 N/A N/A Universal Universal Vertical Vertical Fixed pattern Cat. No. Ref. No. Type RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX RT2SNHVFIX 405621 405621 405621 405621 Vertical Vertical Vertical Vertical Rear Connections specified in multiples of 3, 4, 6 or 8 dependant on 3 or 4 pole configuration - top and / or bottom connections. Front access connections Withdrawable TOP connections BOTTOM connections Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 2 800 to 3200 2 4000 3 4 3 4 FA32WH32T FA42WH32T FA32WH40T FA42WH40T 405973 405974 405975 405976 FA32WH32B FA42WH32B FA32WH40B FA42WH40B 405553 405554 405555 405556 Front access connections Fixed pattern TOP connections BOTTOM connections B.12 Frame size Rating (A) Poles Cat. No. Ref. No. Cat. No. Ref. No. 2 800 to 3200 2 4000 3 4 3 4 FA32FH32T FA42FH32T FA32FH40T FA42FH40T 405985 405986 405987 405988 FA32FH32B FA42FH32B FA32FH40B FA42FH40B 405565 405566 405567 405568 M-PACT Plus Cassette only Basic cassette with flat copper terminals rear connected (800-3200A), integral racking handle, safety shutters and lockable safety features. 4000A units fitted with rear vertical terminals as standard (not to be removed). Frame size Rating (A) Poles Cat. No. Ref. No. 2 800 to 3200 2 4000 3 4 3 4 MH32C32 MH42C32 MH32C40 MH42C40 405357 405356 405359 405358 Basic circuit breaker manually operated, automatic (must be fitted with an M-Pro Protection Unit as listed on page B15), 5 NO and 3 NC auxiliary switches and cluster contacts. Frame size Rating (A) Poles 2 800 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 4 2 2 2 2 2 2 2 1000 1250 1600 2000 2500 3200 4000 Position of the neutral Left Right Left Right Left Right Left Right Left Right Left Right Left Right Left Right Cat. No. Ref. No. MH32M08-A MH4L2M08-A MH4R2M08-A MH32M10-A MH4L2M10-A MH4R2M10-A MH32M12-A MH4L2M12-A MH4R2M12-A MH32M16-A MH4L2M16-A MH4R2M16-A MH32M20-A MH4L2M20-A MH4R2M20-A MH32M25-A MH4L2M25-A MH4R2M25-A MH32M32-A MH4L2M32-A MH4R2M32-A MH32M40-A MH4L2M40-A MH4R2M40-A 405997 405998 406244 405999 406000 406246 406001 406002 406248 406003 406004 406250 406005 406006 406252 406007 406008 406254 406009 406010 406256 406011 406012 406258 ACB’s - type H Moving portion only A B C X Earthing device Frame size Rating (A) Poles Cat. No. Ref. No. 2 800 to 4000 3 4 EDF23P40 EDF24P40 405665 405664 B.13 M-PACT Plus Air circuit breaker - type C - 100kA - Non-automatic Frame 3 Basic circuit breaker manually operated, non automatic, 4 NO and 6 NC auxiliary switches. Withdrawable pattern: 5000A: rear horizontal / vertical - 6300A: rear vertical. Fixed pattern: rear horizontal. Withdrawable and fixed pattern Withdrawable Rating (A) Poles 3 3 5000 6300 3 3 Cat. No. MC33W50 MC33W63 Fixed pattern Ref. No. Cat. No. Ref. No. 406700 406702 MC33F50 - 406703 - Order codes Frame size A B C X Air circuit breaker - type C - 100kA - Automatic Frame 3 (Please select trip unit type in page B.15) Basic circuit breaker manually operated, automatic, 4 NO and 6 NC auxiliary switches. Withdrawable pattern: 5000A: rear horizontal / vertical - 6300A: rear vertical. Fixed pattern: rear horizontal. Automatic breaker include in standard, one alarm contact (N/O). Withdrawable and fixed pattern Withdrawable B.14 Frame size Rating (A) Poles 3 3 5000 6300 3 3 Cat. No. MC33W50 - A MC33W63 - A Fixed pattern Ref. No. Cat. No. Ref. No. 406898 406899 MC33F50 - A - 406900 - M-PACT Plus M-PRO protection relays Frame 1, 2 & 3 M-PRO protection relay Type Cat. No. Ref. No. MPRO17PLUSF1&2 MPRO18 PLUSF1&2 MPRO17PLUSF3 405327 405329 406879 MPRO18PLUSF3-ENG 406889 MPRO18PLUSF3-FR 406890 MPROPLUSUEF MPROPLUSNTL100 MPROPLUSNTL50 MPROPLUSUEF3P3W 405331 406910 406911 405535 M-PRO 30L protection unit M-PRO 30 L protection unit with Restricted Earth Fault only (English) M-PRO 30L protection unit French version M-PRO 30L protection unit (English version) without auto/manual reset button M-PRO 30L protection unit (French version) without auto/manual reset button M-PRO 30H protection unit M-PRO 30 H protection unit with Restricted Earth Fault only (English) M-PRO 30H protection unit French version M-PRO 30H protection unit (English version) without auto/manual reset button M-PRO 30H protection unit (French version) without auto/manual reset button M-PRO 40L protection unit English version with MODBUS protocol M-PRO 40L protection unit French version with MODBUS protocol M-PRO 40L protection unit (English version) without auto/manual reset button M-PRO 40L protection unit (French version) without auto/manual reset button M-PRO 40H protection unit English version with MODBUS protocol M-PRO 40H protection unit French version with MODBUS protocol M-PRO 40H protection unit (English version) without auto/manual reset button M-PRO 40H protection unit (French version) without auto/manual reset button MPRO30L-ENG MPRO30LR MPRO30L-FRF MPRO30L-ENGNR MPRO30L-FRFNR MPRO30H-ENG MPRO30HR MPRO30H-FRF MPRO30H-ENGNR MPRO30H-FRFNR MPRO40L-ENG MPRO40L-FRF MPRO40L-ENGNR MPRO40L-FRFNR MPRO40H-ENG MPRO40H-FRF MPRO40H-ENGNR MPRO40H-FRFNR 406055 406058 405128 406108 406102 406056 406057 405129 406109 406103 405530 405130 406110 406104 405534 405131 406111 406105 Restricted Earth Fault Protection (M-PRO 30 only) Standby Earth Fault Protection ( M-PRO 30 only) M-PRO 30/40 no-trip on fatal error (warn only) software facility Communications facility (MODBUS protocol) Auxiliary Power Unit Portable Test Unit (for M-PRO 17 or 18 Plus) UK power lead Portable Test Unit (for M-PRO 17 & 18 Plus) Euro power lead Portable Test Unit (for M-PRO 30/40) Euro power lead Portable Test Unit (for M-PRO 30/40) UK power lead Portable Power Box (for M-PRO 30/40) Add-on Mechanical Alarm Contact (1 x N/O) Add-on Mechanical Alarm Contact (1 x N/C) Spare PAMM for use with M-PRO 20 Spare PAMM for use with M-PRO 30 or M-PRO 40 MPROREF MPROSEF MPRONTSW MPROCOM MPROAPU MPROPTU17 MPROPLUSTU-EURO MPROPTU-EURO MPROPTU MPROPPB MPROMAC MPROMACNC PAMM20 PAMM30/40 405537 405538 405540 405545 405547 405550 405222 405223 405551 405552 405575 406777 405297 405299 Operations manual(1) French Spanish German Italian Portuguese Dutch Polish MPRO18PLUSF3-G ACB’s - type C M-PRO 17 Plus (for Frame size 1 & 2) for overcurrrent and short circuit protection only M-PRO 18 Plus (Digital display) for overcurrrent and short circuit protection only M-PRO 17 Plus (for Frame size 3 M-PACT Plus) - overcurrrent and short circuit protection only (non-resettable) M-PRO 18 Plus (for Frame size 3 M-PACT Plus) - overcurrrent and short circuit protection only (non-resettable) M-PRO 18 Plus (for Frame size 3 M-PACT Plus) - overcurrrent and short circuit protection only (non-resettable) M-PRO 18 Plus (for Frame size 3 M-PACT Plus) - overcurrrent and short circuit protection only (non-resettable) Unrestricted Earth Fault option for M-PRO 17 and 18 Plus protection relay's. 100% rated Neutral Protection option for M-PRO 17 and 18 Plus protection unit 50% rated Neutral Protection for M-PRO 17 and 18 Plus protection unit 3 phase 3 wire Unrestricted Earth Fault option for M-PRO 17 Plus and 18 Plus A B C X 406372 406373 406374 406375 406376 406377 406378 (1) English manual standard available in packaging. B.15 M-PACT Plus Frame 1 & 2 Electrical accessories MPRO optional features Voltage Cat. No. Ref. No. 24/30V 48V 110/130V 220/250V 380/440V DC DC AC/DC AC/DC AC/DC ST30 ST48 ST130 ST250 ST440 405380 405382 405386 405388 405389 Motor operator (MOP) 24/30V 48V 110/130V 110/130V 220/250V DC DC AC DC AC/DC MOP30 MOP48 MOP130A MOP130D MOP250A 405440 405442 405446 405917 405448 Closing coil (CC) 24/30V 48V 110/130V 220/250V DC DC AC/DC AC/DC CC30 CC48 CC130 CC250 405420 405422 405426 405428 Under voltage release (UV) 24/30V 48V 110/130V 110/130V 220/250V 380/440V DC DC AC DC AC AC UV30 UV48 UV130A UV130D UV250 UV440 405400 405402 405406 405407 405408 405409 Under voltage release time delayed (UVTD) 48V 110/130V 220/250V 380/440V DC AC AC AC UVTD48 UVTD130 UVTD250 UVTD440 406322 406326 405411 405413 250V 250V AC/DC AC/DC CSWFF CSWL 405580 405581 Springs charged signal ( x 1 n/o) SCC 405450 Springs charged contact ( x 1 c/o) 2WPFC 405451 Trip circuit supervision (shunt trip required) TRIPCS 406112 Order codes Range Shunt trip (ST) A B C X Carriage switch B.16 Factory fitted Loose kit form M-PACT Plus Frame 3 Electrical accessories Shunt trip (ST) Closing coil (CC) Voltage 24V 48V 60V 110V 220V 110V 240V DC DC DC DC DC AC AC F3ST24D F3ST48D F3ST60D F3ST110D F3ST220D F3ST110A F3ST240A Cat. No. 406707 406708 406709 406710 406712 406714 406717 24V 48V 60V 110V 220V 110V 230V 220V 240V DC DC DC DC DC AC AC AC AC F3MOP24D F3MOP48D F3MOP60D F3MOP110D F3MOP220D F3MOP110A F3MOP230A F3MOP220A F3MOP240A 406750 406751 406752 406754 406757 406753 406756 406755 406758 24V 48V 60V 110V 110V 220V 110…120V 220…240V DC DC DC AC DC DC AC AC F3CC24D F3CC48D F3CC60D F3CC110A F3CC110D F3CC220D F3CC120A F3CC240A 406723 406724 406725 406726 406727 406729 406730 406731 Ref. No. Electrical accessories Motor operator (MOP) Range A B C Undervoltage release Carriage switch Microswitch (on drive) 24V 48V 60V 110V 220V 230/240V DC DC DC AC/DC AC/DC AC F3UV24D F3UV48D F3UV60D F3UV110 F3UV220 F3UV240A 406732 406733 406734 406735 406737 406741 1 switch 2 switches 3 switches 4 switches 2NO,2NC 4NO,4NC 6NO,6NC 8NO,8NC F3CSW22 F3CSW44 F3CSW66 F3CSW88 406743 406744 406745 406746 F3MSRTC F3MSDCS 406748 406749 Signal "ready to close" (M4) Signal "drive charged" (M3) X B.17 M-PACT Plus Frame 1, 2 & 3 Type A: order 1 interlock kit and 1 cable per ACB Type B: order 1 interlock kit and 2 cable per ACB Type C: order 1 interlock kit and 2 cable per ACB Type D: order 1 interlock kit and 1 cable per Supply breaker plus 1 interlock kit for the Control breaker and 2 cables For type D configuration 2 Supply Breakers and one Control Breaker are required. Mechanical accessories Type A - 2 way interlock / Cable 2 way Interlocking Frame size Version Poles 1 Withdrawable 3 4 3 4 3 4 3 4 3 3 Order codes Fixed A 2 Withdrawable Fixed 3 Withdrawable Fixed Cat. No. Ref. No. 406342 406343 406340 406341 405459 405461 405463 405465 406760 406762 B13WCI3PW B13WCI4PW B13WCI3PF B13WCI4PF B13WCIF23PW B13WCIF24PW B13WCIF23PF B13WCIF24PF 406350 406351 406348 406349 405475 405477 405479 405481 Frame size Version Poles Cat. No. Ref. No. 1 Withdrawable 3 4 3 4 3 4 3 4 C23WCI3PW C23WCI4PW C23WCI3PF C23WCI4PF C23WCIF23PW C23WCIF24PW C23WCIF23PF C23WCIF24PF 406358 406359 406356 406357 405491 405493 405495 405497 2 Withdrawable Fixed C X 2WCI3PW 2WCI4PW 2WCI3PF 2WCI4PF 2WCIF23PW 2WCIF24PW 2WCIF23PF 2WCIF24PF MICWDF33P MICFXF33P Ref. No. Type D - 1 from 3 way interlock/cable - Supply Breakers Type D - 1 from 3 way interlock/cable - Control Breaker Frame size Version Poles Cat. No. Ref. No. Cat. No. Ref. No. 1 Withdrawable 3 4 3 4 3 4 3 4 D13WCI3PW D13WCI4PW D13WCI3PF D13WCI4PF D13WCIF23PW D13WCIF24PW D13WCIF23PF D13WCIF24PF 406366 406367 406364 406365 405511 405513 405515 405517 D13WCI3PWCON D13WCI4PWCON D13WCI3PFCON D13WCI4PFCON D13WCIF23PWCON D13WCIF24PWCON D13WCIF23PFCON D13WCIF24PFCON 406966 406967 406968 406969 406970 406971 406972 406973 Fixed 2 Withdrawable Fixed Cable for interlock (for Frame 1 & 2 only) Length Cat. No. Ref. No.(1) 1.0 metre 1.6 metre 2.0 metre 2.5 metre 3.0 metre 3.5 metre 4.0 metre 100BCMCI 160BCMCI 200BCMCI 250BCMCI 300BCMCI 350BCMCI 400BCMCI 405531 405532 405533 405610 405611 405612 405613 (1) Reference is for one cable B.18 one interlock kit for frame 3 include one 2,3 m cable Type C - 2 from 3 way interlock / Cable Fixed B Cat. No. Type B - 1 from 3 way interlock / Cable M-PACT Plus Frame 1, 2 & 3 Interlocks Frame size 3 Item Cat. No. Ref. No. Castell key breaker interlock (supplied loose) (1) CASLOK 405570 Fortress key breaker interlock (supplied loose) (1) FORLOK 405569 (1) Profalux key breaker interlock (supplied loose) PROLOK 405572 (1) Profalux key cassete interlock (supplied loose) PROCAS 405574 (2) Ronis key breaker interlock (factory fitted) RONLKEY 406335 (2) Ronis key breaker interlock (supplied loose) RONWKEY 406338 Ronis key breaker interlock (supplied loose) ((1) RONLOK 405571 (2) Ronis key cassete interlock (factory fitted) RONWKEYFF 406339 (2) Ronis key cassete interlock (supplied loose) RONCASLD 406336 Ronis key cassete interlock (supplied loose) (1) RONCASNK 406337 (1) Ronis key cassete interlock (factory fitted) RONCAS 405573 Castell key breaker interlock (factory fitted) (1) CASF3FF 406767 (2) Ronis key breaker interlock (factory fitted) RONF3FF 406768 (1) Castell key breaker interlock (supplied loose) CASF3LD 406769 (2) Ronis key breaker interlock (supplied loose) RONF3LD 406770 (1) Without lock and key (2) With lock and key Frame size 1, 2 3 Item Operations counter Left hand door interlock - hinged right Right hand door interlock - hinged left Mis-insertion device (factory fitted) Mis-insertion device (supplied loose) IP54 door Handling (lifting) truck Spare or replacement racking handle Operator counter Cat. No. Ref. No. MOC DILHS DIRHS ACBMID ACBMIL IP54DOOR ACBLIFT MPRACKHAN F3MOC 405576 405578 405579 405605 405505 405606 405607 406393 406771 Mechanical accessories 1, 2 Miscellaneous A B C X B.19 M-PACT Plus Frame 1, 2 & 3 Spare parts Neutral / Earth leg (4th) Current transformer with mounting kit Neutral (4th) Rogowski coil with mounting kit Order codes Current transformer Frame size Rating (A) 1 2 1 2 1 2 1 2 1 2 1 2 2 2 800 1000 1250 1600 2000 2500 3200 4000 Cat. No. Ref. No. ELCT8001 ELCT8002 ELCT10001 ELCT10002 ELCT12501 ELCT12502 ELCT16001 ELCT16002 ELCT20001 ELCT20002 ELCT25001 ELCT25002 ELCT32002 ELCT40002 405683 405713 405684 405714 405685 405715 405686 405716 405687 405717 405688 405718 405689 405690 Rogowski coil Cat. No. Ref. No. RCMK8001 RCMK8002 RCMK10001 RCMK10002 RCMK12501 RCMK12502 RCMK16001 RCMK16002 RCMK20001 RCMK20002 RCMK25001 RCMK25002 RCMK32002 RCMK40002 405703 405723 405704 405724 405705 405725 405706 405726 405707 405727 405708 405728 405709 405710 Spare items available as SINGLE unit ONLY Fixed and moving arcing contact Fixed A B C X (1) Frame size Rating (A) 1 1 2 2 1 1 2 2 2 2 800 to1600 2000 to 2500 3200 4000 800 to1600 2000 to 2500 3200 4000 800 to3200 4000 ACB Qty. required per pole type S S S S N N N N H H 2 4 6 6 3 4 6 6 6 6 Moving Cat. No. Ref. No. Qty. required per pole Cat. No. Ref. No. FACS116 FAC125 FAC232 FAC240 FACN116 FAC125 FAC232 FAC240 FAC232 FAC240 405738 405742 405744 405746 405740 405742 405744 405746 405744 405746 1 1 1 1 1 1 1 1 1 1 MACS116 MAC125 MAC232 MAC240 MACN116 MAC125 MAC232 MAC240 MAC232 MAC240 405739 405743 405745 405747 405741 405743 405745 405747 405745 405747 Cluster contacts Frame size Rating (A) ACB type Per pole 1 800 to1250 S 1 2000 to 2500 S 2 3200 S 2 4000 S 1 800 to1600 (N) and 1600 (S) N 1 2000 to 2500 N 2 3200 N 2 4000 N 2 800 to 3200 H 2 4000 H Universal Cluster pliers (to remove cluster contact) 2 2 2 2 2 2 2 2 2 2 Cat. No. Ref. No. CLCS116 CLC125 CLC232 CLC240 CLCN116 CLC125 CLC232 CLC240 CLC232 CLC240 UNIPLIER 405769 405771 405772 405773 405770 405771 405772 405773 405772 405773 405800 Cat. No. Ref. No. ARC16 ARC25 ARC32SN ARC32H ARC40SN ARC40H F3ARC 405787 405790 405791 405788 405792 405789 406776 Arc chute Frame size Rating (A) ACB type Per pole 1 1 2 2 2 2 3 400 to 1600 <2500 3200 3200 4000 4000 5000 to 6300 S S&N S &N H S &N H C 1 1 1 1 1 1 4 One piece only Main and arcing contact Arcing contact Main contact Frame size Rating (A) Per pole (2) Cat. No. Ref. No. Per pole Cat. No. Ref. No. 3 3 5000 6300 1 set 1 set F3ACK F3ACK 406772 406772 1 set 1 set F3MCS50 F3MCS63 406774 406775 (1) Rogoswki coil provided with twisted pair of cable (max. length 2 m) (2) 1 set includes all parts required for fixed and moving parts for 1 pole. B.20 M-PACT Plus C.2 C.4 C.5 C.6 C.9 C.13 C.15 C.16 Wiring diagrams Circuit breakers M-PRO 17, 17 Plus & 18 Plus M-PRO 30/40 Dimensional drawings Circuit breaker - Type S - 50kA Horizontal, rear access connection - Fixed pattern Rear access connection - Withdrawable pattern Front access connection - Withdrawable pattern Front access connection - Fixed pattern Front access connection - Withdrawable pattern Technical overview A Order codes B Wiring diagrams / Dimensional drawings C C.18 C.21 C.24 C.25 C.26 C.27 Circuit breaker - Type N - 65kA Horizontal, rear access connection - Fixed pattern Rear access connection - Withdrawable pattern Front access connection - Fixed pattern Front access connection - Withdrawable pattern Front access connection - Fixed pattern Front access connection - Withdrawable pattern C.28 C.29 C.31 C.32 Circuit breaker - Type H - 80kA Horizontal, rear access connection - Fixed pattern Rear access connection - Withdrawable pattern Front access connection - Fixed pattern Front access connection - Withdrawable pattern C.33 Circuit breaker - Type C - 100kA Rear and horizontal connection - Withdrawable and fixed version C.35 C.37 C.38 C.39 C.40 Adaptor connections Door cut-outs Cassette mounting details 2-Way cable interlocking 3-Way cable interlocking Numerical index X C.1 M-PACT Plus Wiring diagrams Wiring diagram Frame 1 & 2 (3 & 4 pole) A B Terminal references C X B1 to B16 C1 to C16 D1 to D6 D7 to D12 D13 to D18 Automatic disconnect L.T. blocks Automatic disconnect L.T. blocks Carriage switch blocks for disconnected position Carriage switch blocks for test position(1) Carriage switch blocks for connected position(1) (1) Changeover contacts can be reconfigured by user. Key C.2 LP1 LP2 LP3 LP4 LP5 LP6 Disconnected indication Test indication Connected indication ACB tripped indication ACB OFF indication ACB ON indication Optional features LP7 CC UV UVTD AL ML M ST Closing springs charged indication Closing coil Undervoltage release Time delayed undervoltage release M-PRO trip alarm (N/O) Charging motor limit switch Closing spring charging motor Shunt trip M-PACT Plus for DC Voltage - X1 Motor Operator Wiring diagram Frame 3 (3 pole) 6 4 2 10 16 X2 18 14 12 20 26 22 28 32 X3 33 30 34 35 46 39 48 DC X14 1 V4 ~ + - M 4 X15 2 X12 X13 2 33 ~ 2 X14 8 31 261 C2 C2 C1 C1 1 A2 U< 14 22 24 264 54 52 64 74 72 84 82 13 21 23 272 53 51 63 73 71 83 81 9 4 22 2 A1 SU-CONTROLUNIT 10 271 X12 3 X15 1 X12 X13 1 12 41 11 19 17 18 8 X13 7 F 42 15 16 F 3 251 251 01 04 X47 20 21 MPRO Plus 11 12 14 13 4 5 201 6 2 1 1 X47 2 AC D C1 201 C2 + X1 1 5 3 9 11 13 15 X2 17 19 21 25 27 29 31 X3 36 37 45 38 Wiring diagrams X12 AC 1 X46 2 32/34 47 Auxiliarypower supply24VDC Tripalarm for w/o breaker X1 + X2 + X3 =X20 Closingcoil Breakerready for close Undervoltage release Shunt trip2 Shunt trip1 + for DC + voltage A B L1 L2 L3 L4 L5 ST1 ST2 UV CC M S1 S2 S3 S4 S5.1; S5.2 M-PRO PLUS APU X1, X2, X3 X20 Terminals 33 Terminals 35 Terminals 34 Terminals 39 - 36 36 37 38 Breaker opened Breaker closed Breaker ready for close Breaker charged Breaker tripped by ETU Shunt trip coil 1 Shunt trip coil 2 Undervoltage trip Closing coil Motor operator Breaker opening switch Breaker opening switch Breaker opening switch SU power off switch Breaker closing switch M-PRO17/18 Plus trip unit Auxiliary power supply Fix breaker terminals Withdrawable breaker terminals SU operating voltage Springs charging motor voltage Closing coil voltage Breaker charged signal C X C.3 M-PACT Plus Wiring diagram M-PRO 17 Plus & 18 Plus - Frame 1 & 2 A8 A9 External Rogowski coil B5 Wiring diagrams Power CT (power inputs 1, 2 , 3 ) B6 Ro gowski coils (analogue input s 1, 2 , 3 ) Rogowski coil (analogue input 4) Unrestricted Eart h / Neutral position TestBox Connection SWITCH I/P TRIP COIL OUTPUT A B Aux. Power input Frame 3 C A8 X A9 External Rogowski coil X3 47 Power CT (power input s 1, 2 , 3 ) Aux. Power input 48 Rogowski coils (analogue input s 1, 2 , 3 ) TestBox Connection SWITCH I/P TRIP COIL OUTPUT Note: X3 = 3 3 - 48, refer pag e 4 for furthur details Connections for M-PRO 17 Plus & 18 Plus Location Terminal LT ‘A’ block* LT ‘A’ block* X3 or X20 X3 or X20 A8 A9 47 48 * not applicable for Frame 3 C.4 Function Remote Rogowski coil - positive for earth fault and/or neutral protection Remote Rogowski coil - negative for earth fault and/or neutral protection Auxiliary power supply input - positive Auxiliary power supply input - negative M-PACT Plus Wiring diagram M-PRO 30/40 Wiring diagrams A B C X Connections for M-PRO 30/40 Terminal Terminal Location M-PRO 30 M-PRO 40 PAMM PAMM PAMM PAMM PAMM PAMM PAMM PAMM PAMM PAMM PAMM PAMM PAMM PAMM PAMM LT ‘B’ block LT ‘B’ block LT ‘B’ block LT ‘B’ block A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 B3 B4 B5 B6 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 B3 B4 B5 B6 Function OUTPUT 4, normally open volt free contact: Operates when the REF (or SEF) element trips the ACB This is used to trip an upstream HV breaker. OUTPUT 3, normally open volt free contact: Operates when M-PRO has opened the ACB due to a trip condition. OUTPUT 2, normally open volt free contact: Load monitoring output operates if pre-trip alarm or load shedding limits are exceeded. OUTPUT 1, normally closed volt free contact, opens under the following conditions: Microprocessor malfunction, primary contact maintenance alarm or a digital input is active. Input 4 Input 3 Input 2 Input 1 Input common Remote Rogowski coil - positive for earth fault and/or neutral protection Remote Rogowski coil - negative for earth fault and/or neutral protection Earth leg CT input - non polarised Auxiliary power supply input - positive Auxiliary power supply input - negative C.5 M-PACT Plus Horizontal, rear access connection Fixed pattern Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Centre line of operating panel Fascia centre Dimensional drawings Type S - 3 pole - Frame size 1, In = 400A to 1600A Fascia centre 100 to door ACB fascia cut-out dimensions A B The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200 mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C X Type S - 4 pole - Frame size 1, In = 400A to 1600A Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Fascia centre Centre line of operating panel Fascia centre 100 to door ACB fascia cut-out dimensions Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.6 The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. M-PACT Plus Horizontal, rear access connection Fixed pattern Type S - 3 pole - Frame size 1, In = 2000A and 2500A Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Fascia centre Centre line of operating panel Dimensions Fascia centre 100 to door ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200 mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. A B C X Type S - 4 pole - Frame size 1, In = 2000A and 2500A Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Fascia centre Centre line of operating panel 100 to door Fascia centre ACB fascia cut-out dimensions Copperwork must be supported within 200 mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. C.7 M-PACT Plus Horizontal, rear access connection Fixed pattern Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Centre line of operating panel Centre line of operating panel Fascia centre Dimensional drawings Type S - 3 pole - Frame size 2, In = 2000A to 4000A Fascia centre 100 to door ACB fascia cut-out dimensions A B The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200 mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C X Type S - 4 pole - Frame size 2, In = 2000A to 4000A Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Fascia centre Centre line of operating panel 100 to door Fascia centre ACB fascia cut-out dimensions Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.8 The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. M-PACT Plus Rear access connection Withdrawable pattern Type S - 3 pole - Frame size 1, In = 400A to 1600A Minimum clearance to cassette side. 382 to door Fascia centre Ventilation 35 Test 50 Disconnected 275 Fully withdrawn Centre line of operating panel Connected 414 ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200 mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. Dimensions Fascia centre Centre line of operating panel A B C X Type S - 4 pole - Frame size 1, In = 400A to 1600A Minimum clearance to cassette side. 382 to door Fascia centre Ventilation Fascia centre Centre line of operating panel 35 Test Connected 414 Centre line of operating panel 50 Disconnected 275 Fully withdrawn ACB fascia cut-out dimensions Copperwork must be supported within 200 mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. C.9 M-PACT Plus Rear access connection Withdrawable pattern Minimum clearance to cassette side. 382 to door Fascia centre Ventilation Centre line of operating panel Fascia centre Dimensional drawings Type S - 3 pole - Frame size 1, In = 2000A & 2500A 35 Test 50 Disconnected 275 Fully withdrawn Centre line of operating panel Connected 414 ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. C X Type S - 4 pole - Frame size 1, In = 2000A & 2500A Minimum clearance to cassette side. 382 to door Fascia centre Ventilation Fascia centre Centre line of operating panel 35 Test 50 Disconnected 275 Fully withdrawn Connected 414 Centre line of operating panel ACB fascia cut-out dimensions Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. C.10 The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. M-PACT Plus Rear access connection Withdrawable pattern Type S - 3 pole - Frame size 2, In = 2000A to 3200A Minimum clearance to cassette side. 382 to door Fascia centre Ventilation Fascia centre 35 Test 50 Disconnected 275 Fully withdrawn Centre line of operating panel Connected 414 ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. Dimensions Centre line of operating panel A B C X Type S - 4 pole - Frame size 2, In = 2000A to 3200A Minimum clearance to cassette side. 382 to door Fascia centre Centre line of operating panel Fascia centre Ventilation 35 Test 50 Disconnected 275 Fully withdrawn Connected 414 Centre line of operating panel ACB fascia cut-out dimensions Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. C.11 M-PACT Plus Rear access connection Withdrawable pattern Must not be removed or fitted horizontally Minimum clearance to cassette side. 382 to door Fascia centre Ventilation Centre line of operating panel Fascia centre Dimensional drawings Type S - 3 pole - Frame size 2, In = 4000A 35 Test 50 Disconnected Centre line of operating panel Connected 414 275 Fully withdrawn ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C X Type S - 4 pole - Frame size 2, In = 4000A Must not be removed or fitted horizontally Minimum clearance to cassette side. 382 to door Ventilation Fascia centre Fascia centre Centre line of operating panel 35 Test 50 Disconnected Connected 414 Centre line of operating panel 275 Fully withdrawn ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.12 M-PACT Plus Front access connection Withdrawable pattern Type S - 3 pole - Frame size 1, In = 400A to 1600A Dimensions ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B C X Type S - 4 pole - Frame size 1, In = 400A to 1600A ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. C.13 M-PACT Plus Front access connection Withdrawable pattern Dimensional drawings Type S - 3 pole - Frame size 1, In = 2000A & 2500A ACB fascia cut-out dimensions A The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. B C X Type S - 4 pole - Frame size 1, In = 2000A & 2500A ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. C.14 M-PACT Plus Front access connection Fixed pattern Type S - 3 pole - Frame size 2, In = 2000A & 4000A Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Minimum clearance to breaker side. Fascia centre Dimensions 100 to door Fascia centre ACB fascia cut-out dimension The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. A B C X Type S - 4 pole - Frame size 2, In = 2000A & 4000A Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Fascia centre Minimum clearance to breaker side. 100 to door Fascia centre ACB fascia cut-out dimension The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.15 M-PACT Plus Front access connection Withdrawable pattern Type S - 3 pole - Frame size 1, In = 400A to 2500A Minimum clearance to cassette side. Fascia centre Dimensional drawings 382 to door Connected 414 50 Disconnected 35 Test Fascia centre ACB fascia cut-out dimensions A The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. B C X Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Type S - 4 pole - Frame size 1, In = 400A to 2500A Minimum clearance to cassette side. Fascia centre 382 to door Connected 414 50 Disconnected 35 Test Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.16 M-PACT Plus Front access connection Withdrawable pattern Type S - 3 pole - Frame size 2, In = 2000A & 4000A Minimum clearance to cassette side. Connected 414 50 Disconnected 35 Test Dimensions Fascia centre 382 to door Fascia centre ACB fascia cut-out dimension The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B C Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. X Type S - 4 pole - Frame size 2, In = 2000A & 4000A Minimum clearance to cassette side. Fascia centre 382 to door Connected 414 50 Disconnected 35 Test Fascia centre ACB fascia cut-out dimension The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.17 M-PACT Plus Horizontal, rear access connection Fixed pattern Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Centre line of operating panel Fascia centre Dimensional drawings Type N - 3 pole - Frame size 1, In = 400A to 1600A Fascia centre 100 to door ACB fascia cut-out dimensions A The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. B Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C X Type N - 4 pole - Frame size 1, In = 400A to 1600A Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Fascia centre Centre line of operating panel Fascia centre 100 to door ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.18 M-PACT Plus Horizontal, rear access connection Fixed pattern Type N - 3 pole - Frame size 1, In = 2000A and 2500A Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Fascia centre 100 to door ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Dimensions Fascia centre Centre line of operating panel A B C X Type N - 4 pole - Frame size 1, In = 2000A and 2500A Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Centre line of operating panel Fascia centre Centre line of operating panel Fascia centre 100 to door ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.19 M-PACT Plus Horizontal, rear access connection Fixed pattern Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Centre line of operating panel Fascia centre Dimensional drawings Type N - 3 pole - Frame size 2, In = 2000A to 4000A Fascia centre 100 to door ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C X Type N - 4 pole - Frame size 2, In = 2000A to 4000A Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Centre line of operating panel Fascia centre Centre line of operating panel Fascia centre 100 to door ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.20 M-PACT Plus Rear access connection Withdrawable pattern Type N - 3 pole - Frame size 1, In = 400A to 2500A Minimum clearance to cassette side. 382 to door Fascia centre Ventilation Fascia centre 35 Test 50 Disconnected 275 Fully withdrawn Centre line of operating panel Connected 414 Dimensions Centre line of operating panel ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. A B C X Type N - 4 pole - Frame size 1, In = 400A to 2500A Minimum clearance to cassette side 382 to door Fascia centre Ventilation Fascia centre Centre line of operating panel 35 Test 50 Disconnected 275 Fully withdrawn Connected 414 Centre line of operating panel ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. C.21 M-PACT Plus Rear access connection Withdrawable pattern Minimum clearance to cassette side. 382 to door Fascia centre Ventilation Centre line of operating panel Fascia centre Dimensional drawings Type N - 3 pole - Frame size 2, In = 2000A to 3200A 35 Test 50 Disconnected 275 Fully withdrawn Centre line of operating panel Connected 414 ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. C X Type N - 4 pole - Frame size 2, In = 2000A to 3200A Minimum clearance to cassette side 382 to door Ventilation Fascia centre Fascia centre Centre line of operating panel 35 Test 50 Disconnected 275 Fully withdrawn Connected 414 Centre line of operating panel ACB fascia cut-out dimensions Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. C.22 The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. M-PACT Plus Rear access connection Withdrawable pattern Type N - 3 pole - Frame size 2, In = 4000A Must not be removed or fitted horizontally Minimum clearance to cassette side. 382 to door Fascia centre Ventilation 35 Test 50 Disconnected Dimensions Fascia centre Centre line of operating panel Centre line of operating panel Connected 414 275 Fully withdrawn ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C X Type N - 4 pole - Frame size 2, In = 4000A Minimum clearance to cassette side. Ventilation Must not be removed or fitted horizontally 382 to door Fascia centre Fascia centre Centre line of operating panel 35 Test 50 Disconnected Connected 414 Centre line of operating panel 275 Fully withdrawn ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.23 M-PACT Plus Front access connection Fixed pattern Type N - 3 pole - Frame size 1, In = 400A to 1600A Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Minimum clearance to breaker side. Fascia centre Dimensional drawings Insulated metal or insulated sheet (customer supplied) 100 to door Fascia centre ACB fascia cut-out dimensions A The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. B C X Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Type N - 4 pole - Frame size 1, In = 400A to 1600A Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Fascia centre Minimum clearance to breaker side. 100 to door Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.24 M-PACT Plus Front access connection Withdrawable pattern Type N - 3 pole - Frame size 1, In = 400A to 2500A Minimum clearance to cassette side. Connected 414 50 Disconnected 35 Test Dimensions Fascia centre 382 to door Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. A B C X Type N - 4 pole - Frame size 1, In = 400A to 2500A Minimum clearance to cassette side. Fascia centre 382 to door Connected 414 50 Disconnected 35 Test Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.25 M-PACT Plus Front access connection Fixed pattern Type N - 3 pole - Frame size 2, In = 2000A to 4000A Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Minimum clearance to breaker side. Fascia centre Dimensional drawings Insulated metal or insulated sheet (customer supplied) 100 to door Fascia centre ACB fascia cut-out dimensions A The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. B C X Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Type N - 4 pole - Frame size 2, In = 2000A to 4000A Minimum clearance to breaker side. Fascia centre Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) 100 to door Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.26 M-PACT Plus Front access connection Withdrawable pattern Type N - 3 pole - Frame size 2, In = 2000A to 4000A Minimum clearance to cassette side. Connected 414 50 Disconnected 35 Test Dimensions Fascia centre 382 to door Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B C Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. X Type N - 4 pole - Frame size 2, In = 2000A to 4000A Minimum clearance to cassette side. Fascia centre 382 to door Connected 414 50 Disconnected 35 Test Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.27 M-PACT Plus Horizontal, rear access connection Fixed pattern Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Insulated metal or insulated sheet (customer supplied) Centre line of operating panel Centre line of operating panel Fascia centre Dimensional drawings Type H - 3 pole - Frame size 2, In = 800A to 4000A Fascia centre 100 to door ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C X Type H - 4 pole - Frame size 2, In = 800A to 4000A Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute removal 182 Min Arc chute removal Centre line of operating panel Fascia centre Centre line of operating panel 100 to door Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.28 M-PACT Plus Rear access connection Withdrawable pattern Type H - 3 pole - Frame size 2, In = 800A to 3200A Minimum clearance to cassette side. 382 to door Fascia centre Ventilation 35 Test 50 Disconnected 275 Fully withdrawn Dimensions Fascia centre Centre line of operating panel Centre line of operating panel Connected 414 ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. C X Type H - 4 pole - Frame size 2, In = 800A to 3200A Minimum clearance to cassette side. Ventilation 382 to door Fascia centre Fascia centre Centre line of operating panel 35 Test 50 Disconnected 275 Fully withdrawn Connected 414 Centre line of operating panel ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Captive plate behind copper terminal, tapped M10 x 1.5 6H. Minimum insertion of screw 16mm. Maximum insertion of screw 34mm. C.29 M-PACT Plus Rear access connection Withdrawable pattern Must not be removed or fitted horizontally Minimum clearance to cassette side. Fascia centre 382 to door Ventilation Centre line of operating panel Fascia centre Dimensional drawings Type H - 3 pole - Frame size 2, In = 4000A 35 Test 50 Disconnected Centre line of operating panel Connected 414 275 Fully withdrawn ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B C X Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Type H - 4 pole - Frame size 2, In = 4000A Minimum clearance to cassette side. Ventilation Must not be removed or fitted horizontally 382 to door Fascia centre Fascia centre Centre line of operating panel Centre line of operating panel 35 Test 50 Disconnected 275 Fully withdrawn Connected 414 ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.30 M-PACT Plus Front access connection Fixed pattern Type H - 3 pole - Frame size 2, In = 800A to 4000A Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute removal Minimum clearance to breaker side. Dimensions Fascia centre 182 Min Arc chute removal 100 to door Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. A B C Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. X Type H - 4 pole - Frame size 2, In = 800A to 4000A Insulated metal or insulated sheet (customer supplied) Minimum space to earth metal and for arc chute 182 Min Arc chute removal Fascia centre Minimum clearance to breaker side. 100 to door Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.31 M-PACT Plus Front access connection Withdrawable pattern Type H - 3 pole - Frame size 2, In = 800A to 4000A Minimum clearance to cassette side. Fascia centre Dimensional drawings 382 to door Connected 414 50 Disconnected 35 Test Fascia centre ACB fascia cut-out dimensions A The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. B C X Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. Type H - 4 pole - Frame size 2, In = 800A to 4000A Minimum clearance to cassette side. Fascia centre 382 to door Connected 414 50 Disconnected 35 Test Fascia centre ACB fascia cut-out dimensions The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. Copperwork must be supported within 200mm of breaker connections – busbars or cables. All connections to be tightened to 50Nm. C.32 M-PACT Plus Rear connection Withdrawable pattern 100*) 282,5 70 70 70 40 30 1) 90 517 7 Dimensions 148 210 Ø14,5 578 min. 282,5 200*) 100*) OFF (83) 100*) TEST (59) 100*) ON (0) Type C - 3 pole - Frame size 3, In = 5000A 3) 124,5 425 30 124,5 574,5 280 Ø9 280 68 280 945 673,5 729 2) 969 756,5 A M-Pact Frame 3 - 5000A 3-pole withdrawable Busbar dimensions: 60x12 - 8 busbars: copper black painted. High-quality M8 screws of properity class 8.8 shall be used to make the connection. The screws shall not be lubricated, the tightening torque is 70Nm. Copperwork must be supported within 100mm of breaker connections - busbars or cables. B *) Min clearances of arc chute to insulated or grounded parts. C Horizontal connection Fixed pattern X Type C - 3 pole - Frame size 3, In = 5000A 100*) 818 100*) 100*) 178 33 183 200*) 100*) X1 M12 Ø14 G S S 20 S 20 8 96 F 39 3 16 101 89 860 902 F 107 60 15 297 327 361 366 367 418 F 165 350 518 F 334 349 411 M12 450 255 60 60 Ø14 ACB fascia cut-out dimensions 282,5 Busbar dimensions: 60x12 - 8 busbars: copper black painted. High-quality M8 screws of properity class 8.8 shall be used to make the connection. The screws shall not be lubricated, the tightening torque is 70Nm. Copperwork must be supported within 100mm of breaker connections - busbars or cables. 15 282,5 The cut-out dimensions give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. 364 60 40 20 526 481 303 *) Min clearances of arc chute to insulated or grounded parts. C.33 M-PACT Plus Rear access connection Withdrawable pattern Ø14,5 min. 70 1) 517 644,5 124,5 30 124,5 Ø9 Busbar dimensions: 120x12 - 8 busbars: copper black painted. High-quality M8 screws of properity class 8.8 shall be used to make the connection. The screws shall not be lubricated, the tightening torque is 70Nm. Copperwork must be supported within 100mm of breaker connections - busbars or cables. *) Min clearances of arc chute to insulated or grounded parts. C.34 280 945 969 2) M-Pact Frame 3 - 6300A 3-pole withdrawable X 280 12 280 68 578 30 30 30 3) 425 A C 70 90 673,5 729 756,5 B 100*) 282,5 200*) 282,5 290 120 25 100*) OFF (83) TEST (59) 100*) 63 Dimensional drawings 100*) ON (0) Type C - 3 pole - Frame size 3, In = 6300A M-PACT Plus Adaptor connections (for cassette only) Rear Adapter Vertical Connection Type S - Frame 1 - In = 400A to 1600A (max) Rear Adapter Horizontal Connection Type S - Frame 1 - In = 400A to 1600A (max) Dimensions A B C Rear Adapter Vertical / Horizontal Connection Type S - Frame 1 - In = 2000A & 2500A (max) Type S - Frame 2 - In = 2000A to 3200A (max) Type N - Frame 1 - In = 400A to 2500A (max) Type N - Frame 2 - In = 2000A to 3200A (max) X Type H - Frame 2 - In = 800A to 3200A (max) C.35 M-PACT Plus Adaptor connections (for cassette only) Copper connections - Front access (Fixed and/or withdrawable) Type S - Frame 1 - In = 400A to 2500A (max) Type S - Frame 2 - In = 2000A to 4000A Type N - Frame 1 - In = 400A to 2500A (max) Type N - Frame 2 - In = 2000A to 4000A Dimensional drawings Type H - Frame 2 - In = 800A to 4000A A B C X IP54 Door (Withdrawable unit only - Frame 1 & 2 only) 479 114.5 391 C.36 M-PACT Plus Door cut-outs Fixed pattern - Facia cut-out Frame 3 Dimensions 15 364 Frame 1 & 2 481 Frame = 42,5 Frame = 102,5 A 303 B The cut-out dimensions shown above give an approximate nominal clearance of 3mm around ACB fascia. These sizes are for guidance and can be scaled if a different aperture is required. C X Withdrawable pattern - Cubicle door/panel Frame 1 & 2 Frame3 Escutcheon (LLA11PD055) Escutcheon seal (LLA11RS001) ACB fascia 16 off 3.0 x 6 Self tapping screws 3.6 19 9 122 384 266.6 281 9 Ø28 405 2 x Ø4.5 358 Frame 1 - Up to 2500A max. = 40 Frame 2 - Up to 4000A max. = 100 3.6 263 9 8 91 186 425 28 52 218 417.2 400 30 28 28 Datum for 16 off Ø 4 holes in door / panel – bottom left hand corner of cassette viewed from front. C.37 M-PACT Plus Cassette Dimensional drawings Cassette mounting details Type S - Frame 1 - In = 400A to 2500A (max) Type S - Frame 2 - In = 2000A to 4000A Type N - Frame 1 - In = 400A to 2500A (max) Type N - Frame 2 - In = 2000A to 4000A Type H - Frame 2 - In = 800A to 4000A rom top to 2500 A (max.) to 2500 A (max.) Cassette viewed from top Type 'S', In = 3200 and 4000 A Type 'N', In = 3200 and 4000 A Type 'H', In = 800 to 4000 A Terminals Ventilation in base of cassette (leave unobstructed) Terminals Ventilation in base of cassette (leave unobstructed) 9,6 All holes 4 Pole only 6 Holes Centre line of operating panel Centre line of operating panel A 3 Pole 358 4 Pole 488 3 Pole 419 4 Pole 549 3 Pole 268 4 Pole 368 B 3 Pole 287 4 Pole 387 3 Pole 329 4 Pole 429 C X Type C - Frame 3 - In = 5000A to 6300A (max) 425 center of cassette 188 Ø9 door breaker cover 124,5 424 68 280 357 280 3 /4 Pole 969 C.38 280 9,6 M-PACT Plus 2-Way cable interlocking Fixed pattern - Front/rear access 140 Min Dimensions 900 Max vertical base to base 2000 Max A Min. bend radius 120 B Min. bend radius 120 C X Withdrawable pattern - Front/rear access Min. clearance below cassette 140 Min Min. clearance below cassette 900 Max vertical base to base 2000 Max Min. bend radius 120 Min. bend radius 120 C.39 M-PACT Plus 3-Way cable interlocking Dimensional drawings Fixed pattern - Front/rear access A B C X C.40 Withdrawable pattern - Front/rear access M-PACT Plus X.1 X.5 Numerical index by reference number Numerical index by catalogue number Technical overview A Order codes B Wiring diagrams / Dimensional drawings C Numerical Index X X.1 M-PACT Plus Numerical index Ref. no. A B C X X.2 403… 403680 403681 405… 405102 405103 405104 405105 405106 405107 405108 405109 405110 405111 405112 405113 405114 405115 405116 405117 405118 405119 405120 405121 405122 405123 405124 405125 405128 405129 405130 405131 405132 405133 405134 405135 405136 405137 405138 405139 405140 405141 405142 405143 405144 405145 405146 405147 405148 405149 405150 405151 405152 405153 405154 405155 405162 405163 405164 405165 405166 405167 405168 405169 405170 405171 405172 405173 405174 405175 405176 405177 405178 405179 405180 405181 405182 405183 405184 405185 405186 405192 405193 405194 405195 405196 405197 405198 Cat. no. Page RT1HOR RT1VER B.2 B.2 MS4L1W04 MS31W04 MS4L1W06 MS31W06 MS4L1W08 MS31W08 MS4L1W10 MS31W10 MS4L1W12 MS31W12 MS4L1W16 MS31W16 MS4L1W20 MS31W20 MS4L1W25 MS31W25 MS4L2W20 MS32W20 MS4L2W25 MS32W25 MS4L2W32 MS32W32 MS4L2W40 MS32W40 MPRO30L-FRF MPRO30H-FRF MPRO40L-FRF MPRO40H-FRF MS4L1F04 MS31F04 MS4L1F06 MS31F06 MS4L1F08 MS31F08 MS4L1F10 MS31F10 MS4L1F12 MS31F12 MS4L1F16 MS31F16 MS4L1F20 MS31F20 MS4L1F25 MS31F25 MS4L2F20 MS32F20 MS4L2F25 MS32F25 MS4L2F32 MS32F32 MS4L2F40 MS32F40 MN4L1W04 MN31W04 MN4L1W06 MN31W06 MN4L1W08 MN31W08 MN4L1W10 MN31W10 MN4L1W12 MN31W12 MN4L1W16 MN31W16 MN4L1W20 MN31W20 MN4L1W25 MN31W25 MN4L2W20 MN32W20 MN4L2W25 MN32W25 MN4L2W32 MN32W32 MN4L2W40 MN32W40 MS4R1F04-A MN4L1F04 MN31F04 MN4L1F06 MN31F06 MN4L1F08 MN31F08 MN4L1F10 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.15 B.15 B.15 B.15 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.4 B.6 B.6 B.6 B.6 B.6 B.6 B.6 Ref. no. Cat. no. Page Ref. no. 405199 405200 405201 405202 405203 405204 405205 405206 405207 405208 405209 405210 405211 405212 405213 405214 405215 405216 405217 405218 405219 405222 405223 405226 405227 405228 405229 405230 405231 405232 405233 405234 405235 405236 405237 405238 405239 405240 405241 405242 405243 405244 405245 405246 405247 405248 405249 405250 405251 405252 405253 405254 405255 405256 405257 405258 405259 405260 405261 405262 405263 405264 405265 405266 405267 405268 405269 405270 405271 405272 405273 405274 405275 405276 405277 405278 405296 405297 405298 405299 405316 405318 405320 405322 405324 405326 405327 405328 MN31F10 MN4L1F12 MN31F12 MN4L1F16 MN31F16 MN4L1F20 MN31F20 MN4L1F25 MN31F25 MN4L2F20 MN32F20 MN4L2F25 MN32F25 MN4L2F32 MN32F32 MN4L2F40 MN32F40 MS4L1F04-A MS31F04-A MS4L1F06-A MS31F06-A MPROPLUSTU-EURO MPROPTU-EURO MH4L2W08 MH32W08 MH4L2W10 MH32W10 MH4L2W12 MH32W12 MH4L2W16 MH32W16 MH4L2W20 MH32W20 MH4L2W25 MH32W25 MS4L1F08-A MS31F08-A MS4L1F10-A MS31F10-A MH4L2W32 MH32W32 MH4L2W40 MH32W40 MS4L1F12-A MS31F12-A MS4L1F16-A MS31F16-A MS4L1F20-A MS31F20-A MS4L1F25-A MS31F25-A MS4L2F20-A MS32F20-A MH4L2F08 MH32F08 MH4L2F10 MH32F10 MH4L2F12 MH32F12 MH4L2F16 MH32F16 MH4L2F20 MH32F20 MH4L2F25 MH32F25 MS4L2F25-A MS32F25-A MS4L2F32-A MS32F32-A MH4L2F32 MH32F32 MH4L2F40 MH32F40 MS4L2F40-A MS32F40-A MS4R1F06-A MS4R1F08-A PAMM20 MS4R1F10-A PAMM30/40 MS4R1W04 MS4R1W06 MS4R1W08 MS4R1W10 MS4R1W12 MS4R1W16 MPRO17plusF1&2 MS4R1W20 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.4 B.4 B.4 B.4 B.15 B.15 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.4 B.4 B.4 B.4 B.10 B.10 B.10 B.10 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.10 B.4 B.4 B.4 B.4 B.10 B.10 B.10 B.10 B.4 B.4 B.4 B.4 B.15 B.4 B.15 B.2 B.2 B.2 B.2 B.2 B.2 B.15 B.2 405329 405330 405331 405332 405334 405336 405338 405340 405341 405342 405343 405344 405345 405346 405347 405348 405349 405350 405351 405352 405353 405354 405355 405356 405357 405358 405359 405360 405361 405362 405363 405364 405365 405366 405368 405370 405372 405374 405376 405378 405380 405381 405382 405384 405386 405387 405388 405389 405390 405391 405392 405393 405400 405402 405404 405406 405407 405408 405409 405410 405411 405412 405413 405414 405415 405416 405417 405418 405419 405420 405422 405424 405425 405426 405428 405430 405432 405434 405436 405438 405440 405442 405444 405445 405446 405448 405450 405451 Cat. no. MPRO18 plusF1&2 MS4R1W25 MPROPlusUEF MS4R2W20 MS4R2W25 MS4R2W32 MS4R2W40 MS41C16 MS31C16 MS41C25 MS31C25 MN41C25 MN31C25 MN42C32 MN32C32 MN42C40 MN32C40 MN4L1W04-A MN31W04-A MN4L1W06-A MN31W06-A MS42C32 MS32C32 MH42C32 MH32C32 MH42C40 MH32C40 MN4L1W08-A MN31W08-A MN4L1W10-A MN31W10-A MS42C40 MS32C40 MS4R1F04 MS4R1F06 MS4R1F08 MS4R1F10 MS4R1F12 MS4R1F16 MS4R1F20 ST30 MS4R1F25 ST48 MS4R2F20 ST130 MS4R2F25 ST250 ST440 MS4R1F12-A MS4R2F32 MS4R1F16-A MS4R2F40 UV30 UV48 MS4R1F20-A UV130A UV130D UV250 UV440 MN4L1W12-A UVTD250 MN31W12-A UVTD440 MN4L1W16-A MN31W16-A MN4L1W20-A MN31W20-A MN4L1W25-A MN31W25-A CC30 CC48 MN4L2W20-A MN32W20-A CC130 CC250 MN4R1W04 MN4R1W06 MN4R1W08 MN4R1W10 MN4R1W12 MOP30 MOP48 MN4L2W25-A MN32W25-A MOP130A MOP250A SCC 2WPFC Page Ref. no. Cat. no. Page B.15 B.2 B.15 B.2 B.2 B.2 B.2 B.3 B.3 B.3 B.3 B.7 B.7 B.7 B.7 B.7 B.7 B.8 B.8 B.8 B.8 B.3 B.3 B.11 B.11 B.11 B.11 B.8 B.8 B.8 B.8 B.3 B.3 B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.16 B.2 B.16 B.2 B.16 B.2 B.16 B.16 B.4 B.2 B.4 B.2 B.16 B.16 B.4 B.16 B.16 B.16 B.16 B.8 B.16 B.8 B.16 B.8 B.8 B.8 B.8 B.8 B.8 B.16 B.16 B.8 B.8 B.16 B.16 B.6 B.6 B.6 B.6 B.6 B.16 B.16 B.8 B.8 B.16 B.16 B.16 B.16 405452 405453 405454 405455 405456 405458 405459 405460 405461 405462 405463 405464 405465 405466 405468 405470 405472 405474 405475 405476 405477 405478 405479 405480 405481 405482 405484 405486 405488 405490 405491 405492 405493 405494 405495 405496 405497 405498 405500 405502 405504 405505 405506 405508 405509 405510 405511 405512 405513 405514 405515 405516 405517 405518 405520 405522 405524 405526 405528 405530 405531 405532 405533 405534 405535 405537 405538 405540 405542 405545 405547 405548 405550 405551 405552 405553 405554 405555 405556 405557 405558 405559 405560 405561 405562 405563 405564 405565 MN4L2W32-A MN32W32-A MN4L2W40-A MN32W40-A MN4R1W16 MN4R1W20 2WCIF23PW MN4R1W25 2WCIF24PW MN4R2W20 2WCIF23PF MN4R2W25 2WCIF24PF MN4R2W32 MN4R2W40 MN4R1F04 MN4R1F06 MN4R1F08 B13WCIF23PW MN4R1F10 B13WCIF24PW MN4R1F12 B13WCIF23PF MN4R1F16 B13WCIF24PF MN4R1F20 MN4R1F25 MN4R2F20 MN4R2F25 MN4R2F32 C23WCIF23PW MN4R2F40 C23WCIF24PW MH4R2W08 C23WCIF23PF MH4R2W10 C23WCIF24PF MH4R2W12 MH4R2W16 MH4R2W20 MH4R2W25 ACBMIL MH4R2W32 MH4R2W40 MH4R2F08 MH4R2F10 D13WCIF23PW MH4R2F12 D13WCIF24PW MH4R2F16 D13WCIF23PF MH4R2F20 D13WCIF24PF MH4R2F25 MH4R2F32 MH4R2F40 MS4R1M04 MS4R1M06 MS4R1M08 MPRO40L-ENG 100BCMCI 160BCMCI 200BCMCI MPRO40H-ENG MPROPLUSUEF3P3W MPROREF MPROSEF MPRONTSW MS4R1M10 MPROCOM MPROAPU MS4R1M12 MPROPTU17 MPROPTU MPROPPB FA32WH32B FA42WH32B FA32WH40B FA42WH40B FA31FN16B FA41FN16B FA31FN25B FA41FN25B FA32FN32B FA42FN32B FA32FN40B FA42FN40B FA32FH32B B.8 B.8 B.8 B.8 B.6 B.6 B.18 B.6 B.18 B.6 B.18 B.6 B.18 B.6 B.6 B.6 B.6 B.6 B.18 B.6 B.18 B.6 B.18 B.6 B.18 B.6 B.6 B.6 B.6 B.6 B.18 B.6 B.18 B.10 B.18 B.10 B.18 B.10 B.10 B.10 B.10 B.19 B.10 B.10 B.10 B.10 B.18 B.10 B.18 B.10 B.18 B.10 B.18 B.10 B.10 B.10 B.3 B.3 B.3 B.15 B.18 B.18 B.18 B.15 B.15 B.15 B.15 B.15 B.3 B.15 B.15 B.3 B.15 B.15 B.15 B.10 B.10 B.10 B.10 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.10 M-PACT Plus Ref. no. Cat. no. FA42FH32B FA32FH40B FA42FH40B FORLOK CASLOK RONLOK PROLOK RONCAS PROCAS MPROMAC MOC DILHS DIRHS CSWFF CSWL MS4R1M16 MS4R1M20 MS4R1M25 MS4R2M20 MS4R2M25 MS4R2M32 MS4R2M40 MN4R1M04 MN4R1M06 RT1UNI RT2UNI MN4R1M08 RT1SVFIX MN4R1M10 ACBMID IP54DOOR ACBLIFT RT1SNVFIX 250BCMCI 300BCMCI 350BCMCI 400BCMCI RT2SNHVFIX RT2SNHVFIX MN4R1M12 MN4R1M16 MN4R1M20 MN4R1M25 MN4R2M20 MN4R2M25 MN4R2M32 MN4R2M40 MH4R2M08 MH4R2M10 MH4R2M12 MH4R2M16 MH4R2M20 MH4R2M25 MH4R2M32 MH4R2M40 MN4L1F04-A MN31F04-A MN4L1F06-A MN31F06-A EDF14P16 EDF13P16 EDF14P25 EDF13P25 EDF24P40 EDF23P40 MN4L1F08-A MN31F08-A MS4R1F25-A ELCT8001 ELCT10001 ELCT12501 ELCT16001 ELCT20001 ELCT25001 ELCT32002 ELCT40002 RCMK8001 RCMK10001 RCMK12501 RCMK16001 RCMK20001 RCMK25001 RCMK32002 RCMK40002 MS4R2F20-A ELCT8002 ELCT10002 ELCT12502 Page Ref. no. Cat. no. B.10 B.10 B.10 B.19 B.19 B.19 B.19 B.19 B.19 B.15 B.19 B.19 B.19 B.16 B.16 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.7 B.7 B.2 B.2 B.7 B.2 B.7 B.19 B.19 B.19 B.2 B.18 B.18 B.18 B.18 B.2 B.12 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.11 B.11 B.11 B.11 B.11 B.11 B.11 B.11 B.8 B.8 B.8 B.8 B.3 B.3 B.3 B.3 B.3 B.3 B.8 B.8 B.4 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.4 B.20 B.20 B.20 405716 405717 405718 405720 405721 405722 405723 405724 405725 405726 405727 405728 405730 405731 405732 405733 405734 405735 405736 405737 405738 405739 405740 405741 405742 405743 405744 405745 405746 405747 405748 405769 405770 405771 405772 405773 405778 405779 405780 405781 405782 405783 405784 405785 405786 405787 405788 405789 405790 405791 405792 405796 405797 405798 405799 405800 405801 405802 405803 405804 405805 405806 405807 405808 405809 405810 405811 405812 405813 405814 405815 405816 405817 405818 405819 405820 405821 405822 405823 405824 405825 405826 405828 405829 405830 405831 405832 405833 ELCT16002 ELCT20002 ELCT25002 MN4L1F10-A MN31F10-A MS4R2F25-A RCMK8002 RCMK10002 RCMK12502 RCMK16002 RCMK20002 RCMK25002 MN4L1F12-A MN31F12-A MN4L1F16-A MN31F16-A MN4L1F20-A MN31F20-A MN4L1F25-A MN31F25-A FACS116 MACS116 FACN116 MACN116 FAC125 MAC125 FAC232 MAC232 FAC240 MAC240 MS4R2F32-A CLCS116 CLCN116 CLC125 CLC232 CLC240 MN4L2F20-A MN32F20-A MN4L2F25-A MN32F25-A MN4L2F32-A MN32F32-A MN4L2F40-A MN32F40-A MS4R2F40-A ARC16 ARC32H ARC40H ARC25 ARC32SN ARC40SN MH4L2W08-A MH32W08-A MH4L2W12-A MH32W10-A UNIPLIER MH32W12-A MH4L2W10-A MS31M04 MS4L1M04 MS31M06 MS4L1M06 MS31M08 MS4L1M08 MS31M10 MS4L1M10 MS31M12 MS4L1M12 MS31M16 MS4L1M16 MS31M20 MS4L1M20 MS31M25 MS4L1M25 MS32M20 MS4L2M20 MS32M25 MS4L2M25 MS32M32 MS4L2M32 MS32M40 MS4L2M40 MH4L2W16-A MH32W16-A MH4L2W20-A MH32W20-A MN4R1W04-A MN31M04 Page Ref. no. Cat. no. B.20 B.20 B.20 B.8 B.8 B.4 B.20 B.20 B.20 B.20 B.20 B.20 B.8 B.8 B.8 B.8 B.8 B.8 B.8 B.8 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.4 B.20 B.20 B.20 B.20 B.20 B.8 B.8 B.8 B.8 B.8 B.8 B.8 B.8 B.4 B.20 B.20 B.20 B.20 B.20 B.20 B.12 B.12 B.12 B.12 B.20 B.12 B.12 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.12 B.12 B.12 B.12 B.8 B.7 405834 405835 405836 405837 405838 405839 405840 405841 405842 405843 405844 405845 405846 405847 405848 405849 405850 405851 405852 405853 405854 405855 405856 405858 405859 405860 405861 405862 405863 405864 405866 405867 405868 405869 405870 405871 405872 405873 405874 405875 405876 405877 405878 405880 405881 405882 405883 405884 405885 405886 405888 405889 405890 405891 405892 405893 405894 405895 405896 405897 405898 405899 405900 405901 405902 405904 405905 405906 405907 405908 405909 405910 405911 405912 405913 405914 405915 405916 405917 405918 405919 405920 405921 405922 405923 405924 405925 405926 MN4L1M04 MN31M06 MN4L1M06 MN31M08 MN4L1M08 MN31M10 MN4L1M10 MN31M12 MN4L1M12 MN31M16 MN4L1M16 MN31M20 MN4L1M20 MN31M25 MN4L1M25 MN32M20 MN4L2M20 MN32M25 MN4L2M25 MN32M32 MN4L2M32 MN32M40 MN4L2M40 MH4L2W25-A MH32W25-A MH4L2W32-A MH32W32-A MH4L2W40-A MH32W40-A MN4R1W06-A MN4R1W08-A MH32M08 MH4L2M08 MH32M10 MH4L2M10 MH32M12 MH4L2M12 MH32M16 MH4L2M16 MH32M20 MH4L2M20 MH32M25 MH4L2M25 MH4L2F08-A MH32F08-A MN4R1W10-A MH32M32 MH4L2M32 MH32M40 MH4L2M40 MH4L2F10-A MH32F10-A MH4L2F12-A MH32F12-A MH4L2F16-A MH32F16-A MH4L2F20-A MH32F20-A MH4L2F25-A MH32F25-A MH4L2F32-A MH32F32-A MH4L2F40-A MH32F40-A MN4R1W12-A MN4R1W16-A MS31M04-A MS4L1M04-A MS31M06-A MS4L1M06-A MS31M08-A MS4L1M08-A MS31M10-A MS4L1M10-A MS31M12-A MS4L1M12-A MS31M16-A MS4L1M16-A MOP130D MS4L1M20-A MS31M25-A MS4L1M25-A FA31WS16T FA41WS16T FA31WS25T FA41WS25T FA32WS32T FA42WS32T Page Ref. no. Cat. no. B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.12 B.12 B.12 B.12 B.12 B.12 B.8 B.8 B.11 B.11 B.11 B.11 B.11 B.11 B.11 B.11 B.11 B.11 B.11 B.11 B.12 B.12 B.8 B.11 B.11 B.11 B.11 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.8 B.8 B.5 B.5 B.5 B.5 B.5 B.5 B.5 B.5 B.5 B.5 B.5 B.5 B.16 B.5 B.5 B.5 B.2 B.2 B.2 B.2 B.2 B.2 405927 405928 405929 405930 405931 405932 405933 405934 405935 405936 405937 405938 405939 405940 405941 405942 405943 405944 405945 405946 405947 405948 405949 405950 405951 405952 405953 405954 405955 405956 405957 405958 405959 405960 405961 405962 405963 405964 405965 405966 405967 405968 405969 405970 405971 405972 405973 405974 405975 405976 405977 405978 405979 405980 405981 405982 405983 405984 405985 405986 405987 405988 405989 405990 405991 405992 405994 405995 405996 405997 405998 405999 406… 406000 406001 406002 406003 406004 406005 406006 406007 406008 406009 406010 406011 406012 406020 406021 FA32WS40T FA42WS40T MS32M20-A MS4L2M20-A MS32M25-A MS4L2M25-A FA31FS16T FA41FS16T FA31FS25T FA41FS25T FA32FS32T FA42FS32T FA32FS40T FA42FS40T MS32M32-A MS4L2M32-A MS32M40-A MS4L2M40-A FA31WN16T FA41WN16T FA31WN25T FA41WN25T FA32WN32T FA42WN32T FA32WN40T FA42WN40T MN31M04-A MN4L1M04-A MN31M06-A MN4L1M06-A FA31FN16T FA41FN16T FA31FN25T FA41FN25T FA32FN32T FA42FN32T FA32FN40T FA42FN40T MN31M08-A MN4L1M08-A MN31M10-A MN4L1M10-A MN31M12-A MN4L1M12-A MN31M16-A MN4L1M16-A FA32WH32T FA42WH32T FA32WH40T FA42WH40T MN31M20-A MN4L1M20-A MN31M25-A MN4L1M25-A MN32M20-A MN4L2M20-A MN32M25-A MN4L2M25-A FA32FH32T FA42FH32T FA32FH40T FA42FH40T MN32M32-A MN4L2M32-A MN32M40-A MN4L2M40-A MN4R1W20-A MS31M20-A MN4R1W25-A MH32M08-A MH4L2M08-A MH32M10-A Page B.2 B.2 B.5 B.5 B.5 B.5 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.5 B.5 B.5 B.5 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.9 B.9 B.9 B.9 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.7 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.10 B.10 B.10 B.10 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.10 B.10 B.10 B.10 B.9 B.9 B.9 B.9 B.8 B.5 B.8 B.13 B.13 B.13 MH4L2M10-A MH32M12-A MH4L2M12-A MH32M16-A MH4L2M16-A MH32M20-A MH4L2M20-A MH32M25-A MH4L2M25-A MH32M32-A MH4L2M32-A MH32M40-A MH4L2M40-A MN4R2W20-A FA31WS16B B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.8 B.2 By reference number 405566 405567 405568 405569 405570 405571 405572 405573 405574 405575 405576 405578 405579 405580 405581 405582 405584 405586 405588 405590 405592 405594 405596 405598 405600 405601 405602 405603 405604 405605 405606 405607 405609 405610 405611 405612 405613 405621 405621 405622 405624 405626 405628 405630 405632 405634 405636 405638 405640 405642 405644 405646 405648 405650 405652 405656 405657 405658 405659 405660 405661 405662 405663 405664 405665 405680 405681 405682 405683 405684 405685 405686 405687 405688 405689 405690 405703 405704 405705 405706 405707 405708 405709 405710 405712 405713 405714 405715 A B C X X.3 M-PACT Plus Numerical index Ref. no. A B C X X.4 406022 406023 406024 406025 406026 406027 406028 406032 406033 406034 406035 406036 406037 406038 406039 406040 406042 406044 406045 406046 406047 406048 406049 406050 406051 406052 406054 406055 406056 406057 406058 406094 406096 406098 406102 406103 406104 406105 406108 406109 406110 406111 406112 406114 406116 406118 406120 406122 406124 406126 406128 406130 406132 406134 406136 406138 406140 406142 406144 406146 406148 406150 406152 406154 406156 406158 406160 406162 406164 406166 406168 406170 406172 406174 406176 406177 406178 406179 406180 406181 406182 406183 406184 406185 406186 406187 406188 406189 Cat. no. FA41WS16B FA31WS25B FA41WS25B FA32WS32B FA42WS32B FA32WS40B FA42WS40B MN4R2W25-A FA31FS16B FA41FS16B FA31FS25B FA41FS25B FA32FS32B FA42FS32B FA32FS40B FA42FS40B MN4R2W32-A MN4R2W40-A FA31WN16B FA41WN16B FA31WN25B FA41WN25B FA32WN32B FA42WN32B FA32WN40B FA42WN40B MN4R1F04-A MPRO30L-ENG MPRO30H-ENG MPRO30HR MPRO30LR MN4R1F06-A MN4R1F08-A MN4R1F10-A MPRO30L-FRFNR MPRO30H-FRFNR MPRO40L-FRFNR MPRO40H-FRFNR MPRO30L-ENGNR MPRO30H-ENGNR MPRO40L-ENGNR MPRO40H-ENGNR TRIPCS MN4R1F12-A MN4R1F16-A MN4R1F20-A MN4R1F25-A MN4R2F20-A MN4R2F25-A MN4R2F32-A MN4R2F40-A MH4R2W08-A MH4R2W12-A MH4R2W10-A MH4R2W16-A MH4R2W20-A MH4R2W25-A MH4R2W32-A MH4R2W40-A MH4R2F08-A MH4R2F10-A MH4R2F12-A MH4R2F16-A MH4R2F20-A MH4R2F25-A MH4R2F32-A MH4R2F40-A MS4R1M04-A MS4R1M06-A MS4R1M08-A MS4R1M10-A MS4R1M12-A MS4R1M16-A MS4R1M20-A MS4R1M25-A MS31W04-A MS4L1W04-A MS31W06-A MS4L1W06-A MS31W08-A MS4L1W08-A MS31W10-A MS4L1W10-A MS31W12-A MS4L1W12-A MS31W16-A MS4L1W16-A MS31W20-A Page Ref. no. B.2 B.2 B.2 B.2 B.2 B.2 B.2 B.8 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.3 B.8 B.8 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.6 B.8 B.15 B.15 B.15 B.15 B.8 B.8 B.8 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.16 B.8 B.8 B.8 B.8 B.8 B.8 B.8 B.8 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.12 B.5 B.5 B.5 B.5 B.5 B.5 B.5 B.5 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 406190 406191 406192 406193 406194 406195 406196 406197 406198 406199 406200 406208 406214 406216 406218 406220 406222 406224 406226 406228 406230 406232 406234 406236 406238 406240 406242 406244 406246 406248 406250 406252 406254 406256 406258 406260 406262 406264 406266 406268 406270 406272 406274 406276 406278 406280 406282 406322 406326 406335 406336 406337 406338 406339 406340 406341 406342 406343 406348 406349 406350 406351 406356 406357 406358 406359 406364 406365 406366 406367 406372 406373 406374 406375 406376 406377 406378 406393 406700 406702 406703 406707 406708 406709 406710 406712 406714 406717 Cat. no. MS4L1W20-A MS31W25-A MS4L1W25-A MS32W20-A MS4L2W20-A MS32W25-A MS4L2W25-A MS32W32-A MS4L2W32-A MS32W40-A MS4L2W40-A MS4R2M20-A MS4R2M25-A MS4R2M32-A MS4R2M40-A MN4R1M04-A MN4R1M06-A MN4R1M08-A MN4R1M10-A MN4R1M12-A MN4R1M16-A MN4R1M20-A MN4R1M25-A MN4R2M20-A MN4R2M25-A MN4R2M32-A MN4R2M40-A MH4R2M08-A MH4R2M10-A MH4R2M12-A MH4R2M16-A MH4R2M20-A MH4R2M25-A MH4R2M32-A MH4R2M40-A MS4R1W04-A MS4R1W06-A MS4R1W08-A MS4R1W10-A MS4R1W12-A MS4R1W16-A MS4R1W20-A MS4R1W25-A MS4R2W20-A MS4R2W25-A MS4R2W32-A MS4R2W40-A UVTD48 UVTD130 RONLKEY RONCASLD RONCASNK RONWKEY RONWKEYFF 2WCI3PF 2WCI4PF 2WCI3PW 2WCI4PW B13WCI3PF B13WCI4PF B13WCI3PW B13WCI4PW C23WCI3PF C23WCI4PF C23WCI3PW C23WCI4PW D13WCI3PF D13WCI4PF D13WCI3PW D13WCI4PW MPRACKHAN MC33W50 MC33W63 MC33F50 F3ST24D F3ST48D F3ST60D F3ST110D F3ST220D F3ST110A F3ST240A Page Ref. no. Cat. no. Page B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.5 B.5 B.5 B.5 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.9 B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.13 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.4 B.16 B.16 B.19 B.19 B.19 B.19 B.19 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.19 B.14 B.14 B.14 B.17 B.17 B.17 B.17 B.17 B.17 B.17 406723 406724 406725 406726 406727 406729 406730 406731 406732 406733 406734 406735 406737 406741 406743 406744 406745 406746 406748 406749 406750 406751 406752 406753 406754 406755 406756 406757 406758 406760 406762 406767 406768 406769 406770 406771 406772 406774 406775 406776 406777 406879 406889 406890 406898 406899 406900 406910 406911 406966 406967 406968 406969 406970 406971 406972 406973 F3CC24D F3CC48D F3CC60D F3CC110A F3CC110D F3CC220D F3CC120A F3CC240A F3UV24D F3UV48D F3UV60D F3UV110 F3UV220 F3UV240A F3CSW22 F3CSW44 F3CSW66 F3CSW88 F3MSRTC F3MSDCS F3MOP24D F3MOP48D F3MOP60D F3MOP110A F3MOP110D F3MOP220A F3MOP230A F3MOP220D F3MOP240A MICWDF33P MICFXF33P CASF3FF RONF3FF CASF3LD RONF3LD F3MOC F3ACK F3MCS50 F3MCS63 F3ARC MPROMACNC MPRO17plusF3 MPRO18plusF3-ENG MPRO18plusF3-FR MC33W50 - A MC33W63 - A MC33F50 - A MPROPLUSNTL100 MPROPLUSNTL50 D13WCI3PWCON D13WCI4PWCON D13WCI3PFCON D13WCI4PFCON D13WCIF23PWCON D13WCIF24PWCON D13WCIF23PFCON D13WCIF24PFCON B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.18 B.18 B.19 B.19 B.19 B.19 B.19 B.20 B.20 B.20 B.20 B.15 B.15 B.15 B.15 B.14 B.14 B.14 B.15 B.15 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 M-PACT Plus Cat. no. Ref. no. Page 405531 B.18 405532 B.18 405533 405610 406340 406342 406341 406343 405463 405459 405465 405461 405451 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.16 405611 B.18 405612 B.18 405613 B.18 405607 405605 405505 405787 405790 405788 405791 405789 405792 B.19 B.19 B.19 B.20 B.20 B.20 B.20 B.20 B.20 406348 406350 406349 406351 405479 405475 405481 405477 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 406356 406358 406357 406359 405495 405491 405497 405493 406767 406769 405570 405426 405428 405420 405422 405771 405772 405773 405770 405580 405581 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.19 B.19 B.19 B.16 B.16 B.16 B.16 B.20 B.20 B.20 B.20 B.16 B.16 406364 406968 406366 406966 406365 406969 406367 406967 405515 406972 405511 406970 405517 406973 405513 406971 405578 405579 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.18 B.19 B.19 405661 405663 405660 405662 405665 405664 405684 B.3 B.3 B.3 B.3 B.3 B.3 B.20 Cat. no. ELCT10002 ELCT12501 ELCT12502 ELCT16001 ELCT16002 ELCT20001 ELCT20002 ELCT25001 ELCT25002 ELCT32002 ELCT40002 ELCT8001 ELCT8002 F… F3ACK F3ARC F3CC110A F3CC110D F3CC120A F3CC220D F3CC240A F3CC24D F3CC48D F3CC60D F3CSW22 F3CSW44 F3CSW66 F3CSW88 F3MCS50 F3MCS63 F3MOC F3MOP110A F3MOP110D F3MOP220A F3MOP220D F3MOP230A F3MOP240A F3MOP24D F3MOP48D F3MOP60D F3MSDCS F3MSRTC F3ST110A F3ST110D F3ST220D F3ST240A F3ST24D F3ST48D F3ST60D F3UV110 F3UV220 F3UV240A F3UV24D F3UV48D F3UV60D FA31FN16B FA31FN16T FA31FN25B FA31FN25T FA31FS16B FA31FS16T FA31FS25B FA31FS25T FA31WN16B FA31WN16T FA31WN25B FA31WN25T FA31WS16B FA31WS16T FA31WS25B FA31WS25T FA32FH32B FA32FH32T FA32FH40B FA32FH40T FA32FN32B FA32FN32T FA32FN40B FA32FN40T FA32FS32B FA32FS32T FA32FS40B FA32FS40T FA32WH32B FA32WH32T FA32WH40B FA32WH40T FA32WN32B Ref. no. Page 405714 405685 405715 405686 405716 405687 405717 405688 405718 405689 405690 405683 405713 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 406772 406776 406726 406727 406730 406729 406731 406723 406724 406725 406743 406744 406745 406746 406774 406775 406771 406753 406754 406755 406757 406756 406758 406750 406751 406752 406749 406748 406714 406710 406712 406717 406707 406708 406709 406735 406737 406741 406732 406733 406734 405557 405957 405559 405959 406033 405933 406035 405935 406045 405945 406047 405947 406021 405921 406023 405923 405565 405985 405567 405987 405561 405961 405563 405963 406037 405937 406039 405939 405553 405973 405555 405975 406049 B.20 B.20 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.20 B.20 B.19 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.17 B.7 B.7 B.7 B.7 B.3 B.3 B.3 B.3 B.6 B.6 B.6 B.6 B.2 B.2 B.2 B.2 B.10 B.10 B.10 B.10 B.7 B.7 B.7 B.7 B.3 B.3 B.3 B.3 B.10 B.10 B.10 B.10 B.6 Cat. no. FA32WN32T FA32WN40B FA32WN40T FA32WS32B FA32WS32T FA32WS40B FA32WS40T FA41FN16B FA41FN16T FA41FN25B FA41FN25T FA41FS16B FA41FS16T FA41FS25B FA41FS25T FA41WN16B FA41WN16T FA41WN25B FA41WN25T FA41WS16B FA41WS16T FA41WS25B FA41WS25T FA42FH32B FA42FH32T FA42FH40B FA42FH40T FA42FN32B FA42FN32T FA42FN40B FA42FN40T FA42FS32B FA42FS32T FA42FS40B FA42FS40T FA42WH32B FA42WH32T FA42WH40B FA42WH40T FA42WN32B FA42WN32T FA42WN40B FA42WN40T FA42WS32B FA42WS32T FA42WS40B FA42WS40T FAC125 FAC232 FAC240 FACN116 FACS116 FORLOK I… IP54DOOR M… MAC125 MAC232 MAC240 MACN116 MACS116 MC33F50 MC33F50 - A MC33W50 MC33W50 - A MC33W63 MC33W63 - A MH32C32 MH32C40 MH32F08 MH32F08-A MH32F10 MH32F10-A MH32F12 MH32F12-A MH32F16 MH32F16-A MH32F20 MH32F20-A MH32F25 MH32F25-A MH32F32 MH32F32-A MH32F40 MH32F40-A MH32M08 MH32M08-A MH32M10 Ref. no. Page 405949 406051 405951 406025 405925 406027 405927 405558 405958 405560 405960 406034 405934 406036 405936 406046 405946 406048 405948 406022 405922 406024 405924 405566 405986 405568 405988 405562 405962 405564 405964 406038 405938 406040 405940 405554 405974 405556 405976 406050 405950 406052 405952 406026 405926 406028 405928 405742 405744 405746 405740 405738 405569 B.6 B.6 B.6 B.2 B.2 B.2 B.2 B.7 B.7 B.7 B.7 B.3 B.3 B.3 B.3 B.6 B.6 B.6 B.6 B.2 B.2 B.2 B.2 B.10 B.10 B.10 B.10 B.7 B.7 B.7 B.7 B.3 B.3 B.3 B.3 B.10 B.10 B.10 B.10 B.6 B.6 B.6 B.6 B.2 B.2 B.2 B.2 B.20 B.20 B.20 B.20 B.20 B.19 405606 B.19 405743 405745 405747 405741 405739 406703 406900 406700 406898 406702 406899 405357 405359 405257 405881 405259 405889 405261 405891 405263 405893 405265 405895 405267 405897 405273 405899 405275 405901 405867 405997 405869 B.20 B.20 B.20 B.20 B.20 B.14 B.14 B.14 B.14 B.14 B.14 B.11 B.11 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.11 B.13 B.11 Cat. no. MH32M10-A MH32M12 MH32M12-A MH32M16 MH32M16-A MH32M20 MH32M20-A MH32M25 MH32M25-A MH32M32 MH32M32-A MH32M40 MH32M40-A MH32W08 MH32W08-A MH32W10 MH32W10-A MH32W12 MH32W12-A MH32W16 MH32W16-A MH32W20 MH32W20-A MH32W25 MH32W25-A MH32W32 MH32W32-A MH32W40 MH32W40-A MH42C32 MH42C40 MH4L2F08 MH4L2F08-A MH4L2F10 MH4L2F10-A MH4L2F12 MH4L2F12-A MH4L2F16 MH4L2F16-A MH4L2F20 MH4L2F20-A MH4L2F25 MH4L2F25-A MH4L2F32 MH4L2F32-A MH4L2F40 MH4L2F40-A MH4L2M08 MH4L2M08-A MH4L2M10 MH4L2M10-A MH4L2M12 MH4L2M12-A MH4L2M16 MH4L2M16-A MH4L2M20 MH4L2M20-A MH4L2M25 MH4L2M25-A MH4L2M32 MH4L2M32-A MH4L2M40 MH4L2M40-A MH4L2W08 MH4L2W08-A MH4L2W10 MH4L2W10-A MH4L2W12 MH4L2W12-A MH4L2W16 MH4L2W16-A MH4L2W20 MH4L2W20-A MH4L2W25 MH4L2W25-A MH4L2W32 MH4L2W32-A MH4L2W40 MH4L2W40-A MH4R2F08 MH4R2F08-A MH4R2F10 MH4R2F10-A MH4R2F12 MH4R2F12-A MH4R2F16 MH4R2F16-A MH4R2F20 Ref. no. Page 405999 405871 406001 405873 406003 405875 406005 405877 406007 405883 406009 405885 406011 405227 405797 405229 405799 405231 405801 405233 405829 405235 405831 405237 405859 405243 405861 405245 405863 405356 405358 405256 405880 405258 405888 405260 405890 405262 405892 405264 405894 405266 405896 405272 405898 405274 405900 405868 405998 405870 406000 405872 406002 405874 406004 405876 406006 405878 406008 405884 406010 405886 406012 405226 405796 405228 405802 405230 405798 405232 405828 405234 405830 405236 405858 405242 405860 405244 405862 405509 406146 405510 406148 405512 406150 405514 406152 405516 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.11 B.11 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 By catalogue number 1… 100BCMCI 160BCMCI 2… 200BCMCI 250BCMCI 2WCI3PF 2WCI3PW 2WCI4PF 2WCI4PW 2WCIF23PF 2WCIF23PW 2WCIF24PF 2WCIF24PW 2WPFC 3… 300BCMCI 350BCMCI 4… 400BCMCI A… ACBLIFT ACBMID ACBMIL ARC16 ARC25 ARC32H ARC32SN ARC40H ARC40SN B… B13WCI3PF B13WCI3PW B13WCI4PF B13WCI4PW B13WCIF23PF B13WCIF23PW B13WCIF24PF B13WCIF24PW C… C23WCI3PF C23WCI3PW C23WCI4PF C23WCI4PW C23WCIF23PF C23WCIF23PW C23WCIF24PF C23WCIF24PW CASF3FF CASF3LD CASLOK CC130 CC250 CC30 CC48 CLC125 CLC232 CLC240 CLCN116 CSWFF CSWL D… D13WCI3PF D13WCI3PFCON D13WCI3PW D13WCI3PWCON D13WCI4PF D13WCI4PFCON D13WCI4PW D13WCI4PWCON D13WCIF23PF D13WCIF23PFCON D13WCIF23PW D13WCIF23PWCON D13WCIF24PF D13WCIF24PFCON D13WCIF24PW D13WCIF24PWCON DILHS DIRHS E… EDF13P16 EDF13P25 EDF14P16 EDF14P25 EDF23P40 EDF24P40 ELCT10001 A B C X X.5 M-PACT Plus Numerical index Cat. no. A B C X X.6 MH4R2F20-A MH4R2F25 MH4R2F25-A MH4R2F32 MH4R2F32-A MH4R2F40 MH4R2F40-A MH4R2M08 MH4R2M08-A MH4R2M10 MH4R2M10-A MH4R2M12 MH4R2M12-A MH4R2M16 MH4R2M16-A MH4R2M20 MH4R2M20-A MH4R2M25 MH4R2M25-A MH4R2M32 MH4R2M32-A MH4R2M40 MH4R2M40-A MH4R2W08 MH4R2W08-A MH4R2W10 MH4R2W10-A MH4R2W12 MH4R2W12-A MH4R2W16 MH4R2W16-A MH4R2W20 MH4R2W20-A MH4R2W25 MH4R2W25-A MH4R2W32 MH4R2W32-A MH4R2W40 MH4R2W40-A MICFXF33P MICWDF33P MN31C25 MN31F04 MN31F04-A MN31F06 MN31F06-A MN31F08 MN31F08-A MN31F10 MN31F10-A MN31F12 MN31F12-A MN31F16 MN31F16-A MN31F20 MN31F20-A MN31F25 MN31F25-A MN31M04 MN31M04-A MN31M06 MN31M06-A MN31M08 MN31M08-A MN31M10 MN31M10-A MN31M12 MN31M12-A MN31M16 MN31M16-A MN31M20 MN31M20-A MN31M25 MN31M25-A MN31W04 MN31W04-A MN31W06 MN31W06-A MN31W08 MN31W08-A MN31W10 MN31W10-A MN31W12 MN31W12-A MN31W16 MN31W16-A MN31W20 Ref. no. Page 406154 405518 406156 405520 406158 405522 406160 405638 406244 405640 406246 405642 406248 405644 406250 405646 406252 405648 406254 405650 406256 405652 406258 405494 406130 405496 406134 405498 406132 405500 406136 405502 406138 405504 406140 405506 406142 405508 406144 406762 406760 405345 405193 405657 405195 405659 405197 405681 405199 405721 405201 405731 405203 405733 405205 405735 405207 405737 405833 405953 405835 405955 405837 405965 405839 405967 405841 405969 405843 405971 405845 405977 405847 405979 405163 405351 405165 405353 405167 405361 405169 405363 405171 405412 405173 405415 405175 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.11 B.13 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.10 B.12 B.18 B.18 B.7 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 Cat. no. MN31W20-A MN31W25 MN31W25-A MN32C32 MN32C40 MN32F20 MN32F20-A MN32F25 MN32F25-A MN32F32 MN32F32-A MN32F40 MN32F40-A MN32M20 MN32M20-A MN32M25 MN32M25-A MN32M32 MN32M32-A MN32M40 MN32M40-A MN32W20 MN32W20-A MN32W25 MN32W25-A MN32W32 MN32W32-A MN32W40 MN32W40-A MN41C25 MN42C32 MN42C40 MN4L1F04 MN4L1F04-A MN4L1F06 MN4L1F06-A MN4L1F08 MN4L1F08-A MN4L1F10 MN4L1F10-A MN4L1F12 MN4L1F12-A MN4L1F16 MN4L1F16-A MN4L1F20 MN4L1F20-A MN4L1F25 MN4L1F25-A MN4L1M04 MN4L1M04-A MN4L1M06 MN4L1M06-A MN4L1M08 MN4L1M08-A MN4L1M10 MN4L1M10-A MN4L1M12 MN4L1M12-A MN4L1M16 MN4L1M16-A MN4L1M20 MN4L1M20-A MN4L1M25 MN4L1M25-A MN4L1W04 MN4L1W04-A MN4L1W06 MN4L1W06-A MN4L1W08 MN4L1W08-A MN4L1W10 MN4L1W10-A MN4L1W12 MN4L1W12-A MN4L1W16 MN4L1W16-A MN4L1W20 MN4L1W20-A MN4L1W25 MN4L1W25-A MN4L2F20 MN4L2F20-A MN4L2F25 MN4L2F25-A MN4L2F32 MN4L2F32-A MN4L2F40 Ref. no. Page 405417 405177 405419 405347 405349 405209 405779 405211 405781 405213 405783 405215 405785 405849 405981 405851 405983 405853 405989 405855 405991 405179 405425 405181 405445 405183 405453 405185 405455 405344 405346 405348 405192 405656 405194 405658 405196 405680 405198 405720 405200 405730 405202 405732 405204 405734 405206 405736 405834 405954 405836 405956 405838 405966 405840 405968 405842 405970 405844 405972 405846 405978 405848 405980 405162 405350 405164 405352 405166 405360 405168 405362 405170 405410 405172 405414 405174 405416 405176 405418 405208 405778 405210 405780 405212 405782 405214 B.8 B.6 B.8 B.7 B.7 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.7 B.7 B.7 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 Cat. no. MN4L2F40-A MN4L2M20 MN4L2M20-A MN4L2M25 MN4L2M25-A MN4L2M32 MN4L2M32-A MN4L2M40 MN4L2M40-A MN4L2W20 MN4L2W20-A MN4L2W25 MN4L2W25-A MN4L2W32 MN4L2W32-A MN4L2W40 MN4L2W40-A MN4R1F04 MN4R1F04-A MN4R1F06 MN4R1F06-A MN4R1F08 MN4R1F08-A MN4R1F10 MN4R1F10-A MN4R1F12 MN4R1F12-A MN4R1F16 MN4R1F16-A MN4R1F20 MN4R1F20-A MN4R1F25 MN4R1F25-A MN4R1M04 MN4R1M04-A MN4R1M06 MN4R1M06-A MN4R1M08 MN4R1M08-A MN4R1M10 MN4R1M10-A MN4R1M12 MN4R1M12-A MN4R1M16 MN4R1M16-A MN4R1M20 MN4R1M20-A MN4R1M25 MN4R1M25-A MN4R1W04 MN4R1W04-A MN4R1W06 MN4R1W06-A MN4R1W08 MN4R1W08-A MN4R1W10 MN4R1W10-A MN4R1W12 MN4R1W12-A MN4R1W16 MN4R1W16-A MN4R1W20 MN4R1W20-A MN4R1W25 MN4R1W25-A MN4R2F20 MN4R2F20-A MN4R2F25 MN4R2F25-A MN4R2F32 MN4R2F32-A MN4R2F40 MN4R2F40-A MN4R2M20 MN4R2M20-A MN4R2M25 MN4R2M25-A MN4R2M32 MN4R2M32-A MN4R2M40 MN4R2M40-A MN4R2W20 MN4R2W20-A MN4R2W25 MN4R2W25-A MN4R2W32 MN4R2W32-A Ref. no. Page 405784 405850 405982 405852 405984 405854 405990 405856 405992 405178 405424 405180 405444 405182 405452 405184 405454 405470 406054 405472 406094 405474 406096 405476 406098 405478 406114 405480 406116 405482 406118 405484 406120 405596 406220 405598 406222 405602 406224 405604 406226 405622 406228 405624 406230 405626 406232 405628 406234 405430 405832 405432 405864 405434 405866 405436 405882 405438 405902 405456 405904 405458 405994 405460 405996 405486 406122 405488 406124 405490 406126 405492 406128 405630 406236 405632 406238 405634 406240 405636 406242 405462 406020 405464 406032 405466 406042 B.8 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.6 B.8 B.7 B.9 B.7 B.9 B.7 B.9 B.7 B.9 B.6 B.8 B.6 B.8 B.6 B.8 Cat. no. MN4R2W40 MN4R2W40-A MOC MOP130A MOP130D MOP250A MOP30 MOP48 MPRACKHAN MPRO17plusF1&2 MPRO17plusF3 MPRO18 plusF1&2 MPRO18plusF3-ENG MPRO18plusF3-FR MPRO18plusF3-G MPRO30H-ENG MPRO30H-ENGNR MPRO30H-FRF MPRO30H-FRFNR MPRO30HR MPRO30L-ENG MPRO30L-ENGNR MPRO30L-FRF MPRO30L-FRFNR MPRO30LR MPRO40H-ENG MPRO40H-ENGNR MPRO40H-FRF MPRO40H-FRFNR MPRO40L-ENG MPRO40L-ENGNR MPRO40L-FRF MPRO40L-FRFNR MPROAPU MPROCOM MPROMAC MPROMACNC MPRONTSW MPROPLUSNTL100 MPROPLUSNTL50 MPROPLUSTU-EURO MPROPlusUEF MPROPLUSUEF3P3W MPROPPB MPROPTU MPROPTU17 MPROPTU-EURO MPROREF MPROSEF MS31C16 MS31C25 MS31F04 MS31F04-A MS31F06 MS31F06-A MS31F08 MS31F08-A MS31F10 MS31F10-A MS31F12 MS31F12-A MS31F16 MS31F16-A MS31F20 MS31F20-A MS31F25 MS31F25-A MS31M04 MS31M04-A MS31M06 MS31M06-A MS31M08 MS31M08-A MS31M10 MS31M10-A MS31M12 MS31M12-A MS31M16 MS31M16-A MS31M20 MS31M20-A MS31M25 MS31M25-A MS31W04 MS31W04-A MS31W06 MS31W06-A Ref. no. Page 405468 406044 405576 405446 405917 405448 405440 405442 406393 405327 406879 405329 406889 406890 406056 406109 405129 406103 406057 406055 406108 405128 406102 406058 405534 406111 405131 406105 405530 406110 405130 406104 405547 405545 405575 406777 405540 406910 406911 405222 405331 405535 405552 405551 405550 405223 405537 405538 405341 405343 405133 405217 405135 405219 405137 405239 405139 405241 405141 405247 405143 405249 405145 405251 405147 405253 405803 405905 405805 405907 405807 405909 405809 405911 405811 405913 405813 405915 405815 405995 405817 405919 405103 406177 405105 406179 B.6 B.8 B.19 B.16 B.16 B.16 B.16 B.16 B.19 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.15 B.3 B.3 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.2 B.4 B.2 B.4 M-PACT Plus Cat. no. Ref. no. Page 405107 406181 405109 406183 405111 406185 405113 406187 405115 406189 405117 406191 405355 405365 405149 405255 405151 405269 405153 405271 405155 405277 405819 405929 405821 405931 405823 405941 405825 405943 405119 406193 405121 406195 405123 406197 405125 406199 405340 405342 405354 405364 405132 405216 405134 405218 405136 405238 405138 405240 405140 405246 405142 405248 405144 405250 405146 405252 405804 405906 405806 405908 405808 405910 405810 405912 405812 405914 405814 405916 405816 405918 405818 405920 405102 406178 405104 406180 405106 406182 405108 406184 405110 406186 405112 406188 405114 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.3 B.3 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.3 B.3 B.3 B.3 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 Cat. no. MS4L1W20-A MS4L1W25 MS4L1W25-A MS4L2F20 MS4L2F20-A MS4L2F25 MS4L2F25-A MS4L2F32 MS4L2F32-A MS4L2F40 MS4L2F40-A MS4L2M20 MS4L2M20-A MS4L2M25 MS4L2M25-A MS4L2M32 MS4L2M32-A MS4L2M40 MS4L2M40-A MS4L2W20 MS4L2W20-A MS4L2W25 MS4L2W25-A MS4L2W32 MS4L2W32-A MS4L2W40 MS4L2W40-A MS4R1F04 MS4R1F04-A MS4R1F06 MS4R1F06-A MS4R1F08 MS4R1F08-A MS4R1F10 MS4R1F10-A MS4R1F12 MS4R1F12-A MS4R1F16 MS4R1F16-A MS4R1F20 MS4R1F20-A MS4R1F25 MS4R1F25-A MS4R1M04 MS4R1M04-A MS4R1M06 MS4R1M06-A MS4R1M08 MS4R1M08-A MS4R1M10 MS4R1M10-A MS4R1M12 MS4R1M12-A MS4R1M16 MS4R1M16-A MS4R1M20 MS4R1M20-A MS4R1M25 MS4R1M25-A MS4R1W04 MS4R1W04-A MS4R1W06 MS4R1W06-A MS4R1W08 MS4R1W08-A MS4R1W10 MS4R1W10-A MS4R1W12 MS4R1W12-A MS4R1W16 MS4R1W16-A MS4R1W20 MS4R1W20-A MS4R1W25 MS4R1W25-A MS4R2F20 MS4R2F20-A MS4R2F25 MS4R2F25-A MS4R2F32 MS4R2F32-A MS4R2F40 MS4R2F40-A MS4R2M20 MS4R2M20-A MS4R2M25 MS4R2M25-A Ref. no. Page 406190 405116 406192 405148 405254 405150 405268 405152 405270 405154 405276 405820 405930 405822 405932 405824 405942 405826 405944 405118 406194 405120 406196 405122 406198 405124 406200 405366 405186 405368 405278 405370 405296 405372 405298 405374 405390 405376 405392 405378 405404 405381 405682 405524 406162 405526 406164 405528 406166 405542 406168 405548 406170 405582 406172 405584 406174 405586 406176 405316 406260 405318 406262 405320 406264 405322 406266 405324 406268 405326 406270 405328 406272 405330 406274 405384 405712 405387 405722 405391 405748 405393 405786 405588 406208 405590 406214 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.3 B.5 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 B.3 B.5 B.3 B.5 Cat. no. MS4R2M32 MS4R2M32-A MS4R2M40 MS4R2M40-A MS4R2W20 MS4R2W20-A MS4R2W25 MS4R2W25-A MS4R2W32 MS4R2W32-A MS4R2W40 MS4R2W40-A P… PAMM20 PAMM30/40 PROCAS PROLOK R… RCMK10001 RCMK10002 RCMK12501 RCMK12502 RCMK16001 RCMK16002 RCMK20001 RCMK20002 RCMK25001 RCMK25002 RCMK32002 RCMK40002 RCMK8001 RCMK8002 RONCAS RONCASLD RONCASNK RONF3FF RONF3LD RONLKEY RONLOK RONWKEY RONWKEYFF RT1HOR RT1SNVFIX RT1SVFIX RT1UNI RT1VER RT2SNHVFIX RT2UNI S… SCC ST130 ST250 ST30 ST440 ST48 T… TRIPCS U… UNIPLIER UV130A UV130D UV250 UV30 UV440 UV48 UVTD130 UVTD250 UVTD440 UVTD48 Ref. no. Page 405592 406216 405594 406218 405332 406276 405334 406278 405336 406280 405338 406282 B.3 B.5 B.3 B.5 B.2 B.4 B.2 B.4 B.2 B.4 B.2 B.4 405297 405299 405574 405572 B.15 B.15 B.19 B.19 405704 405724 405705 405725 405706 405726 405707 405727 405708 405728 405709 405710 405703 405723 405573 406336 406337 406768 406770 406335 405571 406338 406339 403680 405609 405603 405600 403681 405621 405601 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.20 B.19 B.19 B.19 B.19 B.19 B.19 B.19 B.19 B.19 B.2 B.2 B.2 B.2 B.2 B.2 B.2 405450 405386 405388 405380 405389 405382 B.16 B.16 B.16 B.16 B.16 B.16 By catalogue number MS31W08 MS31W08-A MS31W10 MS31W10-A MS31W12 MS31W12-A MS31W16 MS31W16-A MS31W20 MS31W20-A MS31W25 MS31W25-A MS32C32 MS32C40 MS32F20 MS32F20-A MS32F25 MS32F25-A MS32F32 MS32F32-A MS32F40 MS32F40-A MS32M20 MS32M20-A MS32M25 MS32M25-A MS32M32 MS32M32-A MS32M40 MS32M40-A MS32W20 MS32W20-A MS32W25 MS32W25-A MS32W32 MS32W32-A MS32W40 MS32W40-A MS41C16 MS41C25 MS42C32 MS42C40 MS4L1F04 MS4L1F04-A MS4L1F06 MS4L1F06-A MS4L1F08 MS4L1F08-A MS4L1F10 MS4L1F10-A MS4L1F12 MS4L1F12-A MS4L1F16 MS4L1F16-A MS4L1F20 MS4L1F20-A MS4L1F25 MS4L1F25-A MS4L1M04 MS4L1M04-A MS4L1M06 MS4L1M06-A MS4L1M08 MS4L1M08-A MS4L1M10 MS4L1M10-A MS4L1M12 MS4L1M12-A MS4L1M16 MS4L1M16-A MS4L1M20 MS4L1M20-A MS4L1M25 MS4L1M25-A MS4L1W04 MS4L1W04-A MS4L1W06 MS4L1W06-A MS4L1W08 MS4L1W08-A MS4L1W10 MS4L1W10-A MS4L1W12 MS4L1W12-A MS4L1W16 MS4L1W16-A MS4L1W20 A B C X 406112 B.16 405800 405406 405407 405408 405400 405409 405402 406326 405411 405413 406322 B.20 B.16 B.16 B.16 B.16 B.16 B.16 B.16 B.16 B.16 B.16 The policy of GE Consumer & Industrial is one of continuous improvement. The right is reserved to alter the design or any structural details of the products at any time without giving notice. April 2006 GE Consumer & Industrial X.7 37420 GE Consumer & Industrial Power Protection GE Consumer & Industrial The Power Protection division (formerly GE Power Controls) of GE Consumer & Industrial is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical distribution components, automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panel-board builders, contractors, OEMs and utilities worldwide GE Consumer & Industrial Power Protection www.ge.com/eu/powerprotection www.gepowercontrols.com M-PACT Plus - Air Circuit Breakers ED.02 GE POWER CONTROLS International Sales Nieuwevaart 51 B-9000 Gent - Belgium Tel. +32/9 265 21 11 Fax +32/9 265 28 90 E-mail: gepcbel@gepc.ge.com M-PACT Plus Air Circuit Breakers 400 - 6300A GE POWER CONTROLS Ltd Lincoln Road Enfield Middlesex EN1 1SB United Kingdom Tel. 0800 587 1251 Fax 0800 587 1239 E-mail: gepcuk@gepc.ge.com GE imagination at work GE imagination at work 680809 Ref. I/3197/E/EX 5.0 Ed. 04/06 © Copyright GE Power Controls 2006 ED.02