www.moeller.net Xpole Industrial Feeder and Branch Circuit Breaker Xpole Industrial, the logical continuation of the development of installation products for industrial applications. From protective switches to modular installation devices to surge protection, everything matches, and the complete range combines all the benefits. Xpole Industrial Product Information Feeder and Branch Circuit Breaker FAZ-NA FAZ-RT (Ring Tonque Connection) We keep power under control. Optimum and Efficient Protection for Every Application When it comes to protection and switching, industry in many countries relies on Moeller products. Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant. Approvals in many countries confirm Moeller builts its products to comply with the latest national and international Regulations. Powerful offering for machine and system builders The Xpole Industrial FAZ-NA, FAZ-RT is available with C and D characteristic in accordance with UL 489, CSA C22.2 No.5.1; UL 1077, CSA C22.2 No.235 and IEC 60947-2 Typical Applications 10 kA UL 489, C22.2 No.5.1 15 kA IEC 60947-2 Feeder and Branch Circuit Protection • Convenience receptacle circuits (internal/external) • Motors (internal/external) • Load circuits leaving the equipment (external) • HACR Equipment (Heating, Air Conditioning, Refrigeration) (internal/external) Supplementary Protection FAZ, FAZ-NA and FAZ-RT • Additional protection for: sensitive equipment, electronic components (e.g. computers) • Motor control circuits without transformers 2 Features • Current limiting Screw not to be lost • SWD (switching duty) – suitable for switching fluorescent lighting loads (In ≤ 20 A) FAZ-NA • Fulfill UL 489, CSA C22.2 No. 5.1 and also IEC 60947-2 Standard • For use in application for which UL 1077 or CSA C22.2 No.235 are also allowed • Shunt trip release and auxiliary switch for subsequent mounting • Separate Version for Ring Tonque Connection (Type FAZ-….-RT), terminal screws can be removed (on both sides) • Module width of only 17,7 mm (per pole) FAZ-RT • Contact Position Indicator (red/green) • Easy installation on DIN rail • Possibility for sealing the toggle in on- or off-position FAZ-RT 3 FAZ complies with the latest national and international Standards Standards – Feeder and Branch Circuit Protection • UL 489 Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection. Products meet the requirements of the National Electrical Code (NEC). • CSA C22.2 No.5.1 Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection (corresponds closely to UL 489 Standard). Products meet the requirements of the Canadian Electrical Code (CEC) Standards – Supplementary Protection • UL 1077 Standard for molded case circuit breakers (MCCB) for supplementary protection of sensitive elctronic equipment or equipment that requires unique or specific overcurrent protection. Products meet the requirements of the National Electrical Code (NEC). • CSA C22.2 No.235 Equivalent to the UL 1077 Standard. Products meet the requirements of the Canadian Electrical Code (CEC). 4 UL Device Printing on front and side Rated Voltage UL/CSA Type Designation Heating, Air Conditioning, Refrigeration Min. distance between front plate and device shoulder EAN-Code According to Standard IEC/EN Rated Breaking Capacity UL/CSA Rated Voltage IEC/EN Current Limiting Switching Duty Terminal Capacity Rated Breaking Capacity IEC/EN Reference Calibration Temperature Rated Impulse Withstand Voltage Utilisation Category German Approval Mark Suitable for 60/75°C wire Length of uninsulated conductor Cu-conductors only Calibration Temperature acc. UL/CSA Rated Voltage UL/CSA Suitable for Insolation Rated Current 5 FAZ-NA Miniature Circuit Breakers FAZ-N NA 10 kA UL/CSA; 15 kA IEC 60947, Characteristic C Rated current In (A) SG11805 FAZ-C0,5/1-NA FAZ-C1/1-NA FAZ-C1,5/1-NA FAZ-C2/1-NA FAZ-C3/1-NA FAZ-C4/1-NA FAZ-C5/1-NA FAZ-C6/1-NA FAZ-C7/1-NA FAZ-C8/1-NA FAZ-C10/1-NA FAZ-C13/1-NA FAZ-C15/1-NA FAZ-C16/1-NA FAZ-C20/1-NA FAZ-C25/1-NA FAZ-C30/1-NA FAZ-C32/1-NA FAZ-C35/1-NA FAZ-C40/1-NA 102077 102078 102079 102080 102081 102082 102083 102084 102085 102086 102087 102088 102089 102090 102091 102092 102093 102094 102095 102096 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FAZ-C0,5/2-NA FAZ-C1/2-NA FAZ-C1,5/2-NA FAZ-C2/2-NA FAZ-C3/2-NA FAZ-C4/2-NA FAZ-C5/2-NA FAZ-C6/2-NA FAZ-C7/2-NA FAZ-C8/2-NA FAZ-C10/2-NA FAZ-C13/2-NA FAZ-C15/2-NA FAZ-C16/2-NA FAZ-C20/2-NA FAZ-C25/2-NA FAZ-C30/2-NA FAZ-C32/2-NA FAZ-C35/2-NA FAZ-C40/2-NA 102157 102158 102159 102160 102161 102162 102163 102164 102165 102166 102167 102168 102169 102170 102171 102172 102173 102174 102175 102176 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FAZ-C0,5/3-NA FAZ-C1/3-NA FAZ-C1,5/3-NA FAZ-C2/3-NA FAZ-C3/3-NA FAZ-C4/3-NA FAZ-C5/3-NA FAZ-C6/3-NA FAZ-C7/3-NA FAZ-C8/3-NA FAZ-C10/3-NA FAZ-C13/3-NA FAZ-C15/3-NA FAZ-C16/3-NA FAZ-C20/3-NA FAZ-C25/3-NA FAZ-C30/3-NA FAZ-C32/3-NA FAZ-C35/3-NA FAZ-C40/3-NA 102237 102238 102239 102240 102241 102242 102243 102244 102245 102246 102247 102248 102249 102250 102251 102252 102253 102254 102255 102256 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 6 Units per package 2-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 SG12205 Article No. 1-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 SG12105 Type Designation Miniature Circuit Breakers FAZ-N NA 10 kA UL/CSA; 15 kA IEC 60947, Characteristic D Rated current In (A) SG11805 Units per package FAZ-D0,5/1-NA FAZ-D1/1-NA FAZ-D1,5/1-NA FAZ-D2/1-NA FAZ-D3/1-NA FAZ-D4/1-NA FAZ-D5/1-NA FAZ-D6/1-NA FAZ-D7/1-NA FAZ-D8/1-NA FAZ-D10/1-NA FAZ-D13/1-NA FAZ-D15/1-NA FAZ-D16/1-NA FAZ-D20/1-NA FAZ-D25/1-NA FAZ-D30/1-NA FAZ-D32/1-NA FAZ-D35/1-NA FAZ-D40/1-NA 102097 102098 102099 102100 102101 102102 102103 102104 102105 102106 102107 102108 102109 102110 102111 102112 102113 102114 102115 102116 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FAZ-D0,5/2-NA FAZ-D1/2-NA FAZ-D1,5/2-NA FAZ-D2/2-NA FAZ-D3/2-NA FAZ-D4/2-NA FAZ-D5/2-NA FAZ-D6/2-NA FAZ-D7/2-NA FAZ-D8/2-NA FAZ-D10/2-NA FAZ-D13/2-NA FAZ-D15/2-NA FAZ-D16/2-NA FAZ-D20/2-NA FAZ-D25/2-NA FAZ-D30/2-NA FAZ-D32/2-NA FAZ-D35/2-NA FAZ-D40/2-NA 102177 102178 102179 102180 102181 102182 102183 102184 102185 102186 102187 102188 102189 102190 102191 102192 102193 102194 102195 102196 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FAZ-D0,5/3-NA FAZ-D1/3-NA FAZ-D1,5/3-NA FAZ-D2/3-NA FAZ-D3/3-NA FAZ-D4/3-NA FAZ-D5/3-NA FAZ-D6/3-NA FAZ-D7/3-NA FAZ-D8/3-NA FAZ-D10/3-NA FAZ-D13/3-NA FAZ-D15/3-NA FAZ-D16/3-NA FAZ-D20/3-NA FAZ-D25/3-NA FAZ-D30/3-NA FAZ-D32/3-NA FAZ-D35/3-NA FAZ-D40/3-NA 102257 102258 102259 102260 102261 102262 102263 102264 102265 102266 102267 102268 102269 102270 102271 102272 102273 102274 102275 102276 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 SG12205 Article No. 1-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 SG12105 Type Designation 3-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 7 Rated current In (A) SG11905 SG12005 Units per package FAZ-C0,5/1-RT FAZ-C1/1-RT FAZ-C1,5/1-RT FAZ-C2/1-RT FAZ-C3/1-RT FAZ-C4/1-RT FAZ-C5/1-RT FAZ-C6/1-RT FAZ-C7/1-RT FAZ-C8/1-RT FAZ-C10/1-RT FAZ-C13/1-RT FAZ-C15/1-RT FAZ-C16/1-RT FAZ-C20/1-RT FAZ-C25/1-RT FAZ-C30/1-RT FAZ-C32/1-RT FAZ-C35/1-RT FAZ-C40/1-RT 102117 102118 102119 102120 102121 102122 102123 102124 102125 102126 102127 102128 102129 102130 102131 102132 102133 102134 102135 102136 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FAZ-C0,5/2-RT FAZ-C1/2-RT FAZ-C1,5/2-RT FAZ-C2/2-RT FAZ-C3/2-RT FAZ-C4/2-RT FAZ-C5/2-RT FAZ-C6/2-RT FAZ-C7/2-RT FAZ-C8/2-RT FAZ-C10/2-RT FAZ-C13/2-RT FAZ-C15/2-RT FAZ-C16/2-RT FAZ-C20/2-RT FAZ-C25/2-RT FAZ-C30/2-RT FAZ-C32/2-RT FAZ-C35/2-RT FAZ-C40/2-RT 102197 102198 102199 102200 102201 102202 102203 102204 102205 102206 102207 102208 102209 102210 102211 102212 102213 102214 102215 102216 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FAZ-C0,5/3-RT FAZ-C1/3-RT FAZ-C1,5/3-RT FAZ-C2/3-RT FAZ-C3/3-RT FAZ-C4/3-RT FAZ-C5/3-RT FAZ-C6/3-RT FAZ-C7/3-RT FAZ-C8/3-RT FAZ-C10/3-RT FAZ-C13/3-RT FAZ-C15/3-RT FAZ-C16/3-RT FAZ-C20/3-RT FAZ-C25/3-RT FAZ-C30/3-RT FAZ-C32/3-RT FAZ-C35/3-RT FAZ-C40/3-RT 102277 102278 102279 102280 102281 102282 102283 102284 102285 102286 102287 102288 102289 102290 102291 102292 102293 102294 102295 102296 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 8 Article No. 2-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 SG12305 Type Designation 1-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 FAZ-RT (with Ring Tonque Connection) Miniature Circuit Breakers FAZ-R RT 10 kA UL/CSA; 15 kA IEC 60947, Characteristic C Miniature Circuit Breakers FAZ-R RT 10 kA UL/CSA; 15 kA IEC 60947, Characteristic D Rated current In (A) SG11905 Units per package FAZ-D0,5/1-RT FAZ-D1/1-RT FAZ-D1,5/1-RT FAZ-D2/1-RT FAZ-D3/1-RT FAZ-D4/1-RT FAZ-D5/1-RT FAZ-D6/1-RT FAZ-D7/1-RT FAZ-D8/1-RT FAZ-D10/1-RT FAZ-D13/1-RT FAZ-D15/1-RT FAZ-D16/1-RT FAZ-D20/1-RT FAZ-D25/1-RT FAZ-D30/1-RT FAZ-D32/1-RT FAZ-D35/1-RT FAZ-D40/1-RT 102137 102138 102139 102140 102141 102142 102143 102144 102145 102146 102147 102148 102149 102150 102151 102152 102153 102154 102155 102156 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FAZ-D0,5/2-RT FAZ-D1/2-RT FAZ-D1,5/2-RT FAZ-D2/2-RT FAZ-D3/2-RT FAZ-D4/2-RT FAZ-D5/2-RT FAZ-D6/2-RT FAZ-D7/2-RT FAZ-D8/2-RT FAZ-D10/2-RT FAZ-D13/2-RT FAZ-D15/2-RT FAZ-D16/2-RT FAZ-D20/2-RT FAZ-D25/2-RT FAZ-D30/2-RT FAZ-D32/2-RT FAZ-D35/2-RT FAZ-D40/2-RT 102217 102218 102219 102220 102221 102222 102223 102224 102225 102226 102227 102228 102229 102230 102231 102232 102233 102234 102235 102236 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FAZ-D0,5/3-RT FAZ-D1/3-RT FAZ-D1,5/3-RT FAZ-D2/3-RT FAZ-D3/3-RT FAZ-D4/3-RT FAZ-D5/3-RT FAZ-D6/3-RT FAZ-D7/3-RT FAZ-D8/3-RT FAZ-D10/3-RT FAZ-D13/3-RT FAZ-D15/3-RT FAZ-D16/3-RT FAZ-D20/3-RT FAZ-D25/3-RT FAZ-D30/3-RT FAZ-D32/3-RT FAZ-D35/3-RT FAZ-D40/3-RT 102297 102298 102299 102300 102301 102302 102303 102304 102305 102306 102307 102308 102309 102310 102311 102312 102313 102314 102315 102316 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 SG12305 Article No. 1-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 SG12005 Type Designation 3-p pole 0.5 1 1.5 2 3 4 5 6 7 8 10 13 15 16 20 25 30 32 35 40 9 FAZ-NA, FAZ-RT Technical Data Miniature Circuit Breakers FAZ-N NA, FAZ-R RT Accessories: Tripping signal switch for subsequent installation Shunt trip release Busbar-System Connection diagrams 1-pole Z-NHK FAZ-XAA-NA Z-SV/UL-16/ 2-pole 3-pole Technical Data Electrical Design according to UL 489, CSA C22.2 No.5.1, IEC 60947-2 Current test marks as printed onto the device Rated voltage UL/CSA 0.5 - 20 A 277/480Y VAC UL/CSA 25 - 40 A 240 VAC IEC 240/415 VAC Rated frequency 50/60 Hz Rated breaking capacity UL/CSA 10 kA IEC 15 kA Characteristic C, D Endurance ≥ 20,000 operating cycles Line voltage connection optional suitable for reverse feed Mechanical Frame size Device height Device width Mounting 45 mm 105 mm 17.7 mm per pole quick fastening with 2 lock-in positions on DIN rail EN 50022 open mouth/lift terminals 1 Wire AWG 18–6 2 Wires AWG 18-10 1 Wire 21 lb-in 2 Wires 25 lb-in independent of position Upper and lower terminals Terminal capacity Terminal fastening torque Mounting Calibration temperature UL 489, CSA C22.2 No.5.1 IEC 60947-2 40°C 30°C Dimensions (mm) 2P 1P 5,5 3P 105 105 45 105 10 17,7 35,4 53,1 44 60 Power loss at In Characteristic C 10 Characteristic D 1p 2p 3p 1p 2p 3p In [A] P [W] P [W] P [W] In [A] P [W] P [W] P [W] 0.5 1.6 3.2 4.7 0.5 1.6 3.2 4.8 1 1.1 2.2 3.4 1 0.8 1.5 2.3 1.5 1.3 2.6 3.9 1.5 1.0 2.1 3.1 2 1.4 2.8 4.3 2 1.0 2.1 3.1 3 1.2 2.4 3.6 3 1.2 2.4 3.6 4 1.4 2.9 4.3 4 1.4 2.9 4.3 5 1.9 3.7 5.6 5 1.5 2.9 4.4 6 1.2 2.3 3.5 6 1.2 2.3 3.5 7 1.4 2.8 4.3 7 1.4 2.8 4.3 8 1.4 2.8 4.2 8 1.2 2.4 3.7 10 1.8 3.6 5.3 10 1.5 3.0 4.5 13 2.4 4.7 7.1 13 2.0 4.1 6.1 15 1.9 3.8 5.6 15 1.5 3.1 4.6 16 2.1 4.3 6.4 16 1.7 3.5 5.2 20 2.9 5.8 8.7 20 1.8 3.7 5.5 25 3.1 6.2 9.3 25 2.6 5.1 7.7 30 3.0 6.0 9.0 30 2.7 5.4 8.1 32 3.4 6.8 10.2 32 3.1 6.2 9.3 35 3.7 7.4 11.0 35 3.8 7.6 11.3 40 4.0 8.1 12.1 40 3.9 7.8 11.6 Tripping Characteristics Influence of ambient temperature T on load carrying capacity 7200 3600 2 tripping characteristic acc. to UL 489 1 1200 1 conventional non-tripping current Int = 1.0 IN (T=40°C) 2 conventional tripping current I t = 1.35 I N: t < 1 h (T=25°C) 3 2.0 IN : t = 12- 120 s (T=25°C) 4 type C: 5 I N: t > 0.1 s 10 I N: t < 0.1 s 6 type D: 10 I N: t > 0.1 s 20 I N: t < 0.1 s 600 300 3 120 1.40 1.30 instantaneous tripping acc. to IEC 60898-1 30 Tripping time t [sec] Load factor KT [I/In ] 60 3 10 5 2 1.20 1.10 1 1.00 0.5 0.2 5 4 0.1 4 0.90 5 D C 0.05 0.02 -10 -20 0 10 20 30 40 50 0.01 Ambient temperature T [°C] 0.005 Maximum load IL at ambient temperature T: 0.002 I L (T) = In KT (T) 0.001 0.0005 1 2 3 4 5 6 7 8 9 10 15 20 30 40 50 I / IN Let-through Energy Characteristic C (0.5-20A), 277V Characteristic C (25-40A), 240V 80000 70000 60000 80000 70000 60000 50000 50000 40000 40000 0 C2 20000 15000 C13 C10 C8 7 C6, C 20000 10000 9000 8000 7000 6000 5000 4000 3000 C40 C35 C32 C30 C25 15000 2 2 C2 C1,5 2000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1500 1500 1000 900 800 700 600 1000 900 800 700 600 C1 500 500 400 400 7000 8000 9000 10000 6000 4000 5000 Characteristic D (25-40A), 240V 80000 70000 60000 80000 70000 60000 50000 50000 0 D2 40000 40000 6 D5 2 D4 10000 9000 8000 7000 6000 D3 D2 D1.5 5000 4000 3000 D1 2000 D35 D32 D30 20000 D25 15000 10000 9000 8000 7000 6000 5000 4000 3000 2000 1500 1500 1000 900 800 700 600 1000 900 800 700 600 500 500 400 D40 30000 2 15000 2 20000 Let-through energy I t [A sec] 1 5,D D1 D13 D10 D8 7 D6,D 30000 400 Prospective short-circuit current [A] 7000 8000 9000 10000 6000 5000 4000 3000 2000 300 1500 7000 8000 9000 10000 6000 5000 4000 3000 2000 1500 1000 D0.5 500 300 500 2 3000 Prospective short-circuit current [A] Characteristic D (0.5-20A), 277V Let-through energy I t [A sec] 2000 500 7000 8000 9000 10000 6000 4000 5000 3000 2000 1500 1000 500 Prospective short-circuit current [A] 1500 300 C0.5 1000 300 1000 2 30000 C5 C4 C3 2 Let-through energy I t [A sec] 5 C1 Let-through energy I t [A sec] 30000 16 ,C Prospective short-circuit current [A] 11 Accessories Accessories Type Designation Article No. Units per package Z-NHK 248434 4 / 120 SG12002 Tripping signal switch Shunt trip release 110-415VAC FAZ-XAA-NA110-415VAC 102036 Shunt trip release 12-110VAC FAZ-XAA-NA12-110VAC 102037 1 1 Busbar 1-phase 6MU Busbar 1-phase 12MU Busbar 1-phase 18MU Busbar 2-phases 6MU Busbar 2-phases 12MU Busbar 2-phases 18MU Busbar 3-phases 6MU Busbar 3-phases 12MU Busbar 3-phases 18MU Extension terminal 35 mm2 Extension terminal 50 mm2 in prep. in prep. in prep. in prep. in prep. in prep. in prep. in prep. in prep. in prep. in prep. 1 1 1 1 1 1 1 1 1 3 / 180 3 / 180 101911 5 / 30 Z-SV/UL-16/1P-1TE/6 Z-SV/UL-16/1P-1TE/12 Z-SV/UL-16/1P-1TE/18 Z-SV/UL-16/2P-2TE/6 Z-SV/UL-16/2P-2TE/12 Z-SV/UL-16/2P-2TE/18 Z-SV/UL-16/3P-3TE/6 Z-SV/UL-16/3P-3TE/12 Z-SV/UL-16/3P-3TE/18 Z-EK/35/UL Z-EK/50/UL Lockout attachment without IS/SPE-1TE lock 12 Accessories Technical Data Tripping Signal Sw itch Z-N N HK € Design according to IEC/EN 60947-5-1, IEC/EN 62019 € Can be mounted subsequently (screws) € The specified minimum voltages are per contact Take into account particularly in case of series connection! € Contact function with relative movement (self-cleaning contacts) € Contact material and design particularly suitable for extra low voltage € The function of one of the two change-over contacts can be switched from • auxiliary switchŽ to • tripping signal switchŽ € Tripping signal contact transmits message of electric tripping, not mechanical switch-off € Test key for contact function • electrical trippingŽ Connection diagram Technical Data Electrical Can be mounted from the left onto Contact function Rated voltage Frequency Rated current Rated thermal current I th Utilisation category A C13 Rated operational current I e Utilisation category A C15 Rated operational current I e Utilisation category DC12 Rated operational current I e Rated insulation voltage U I M inimum operational voltage per contact U min M inimum operational current I min Rated peak withstand voltage U imp (1.2/50µ) Conditional short circuit current I k with back-up fuse 6A M ax. back-up fuse, overload and short circuit FAZ-NA, FAZ-RT, FAZ-XAA-NA 2CO 230 V 50/60 Hz 2A 2A M echanical Tripping indicator • electrical trippingŽ Frame size Device height Device width M ounting Degree of protection, built-in Terminal protection 3A /250V A C 2A /250V A C 0.5A /110V DC 250 V A C 5 V DC 10 mA DC 2.5 kV Terminals Terminal capacity Terminal screws Fastening torque of terminal screws blue/white 45 mm 80 mm 8.8 mm (0.5M U) onto switching dev. IP40 finger and hand touch safe according to BGV A 3, ÖV E-EN 6 lift terminals 18-14 AW G M 3 (Pozidrive Z0) 7 lb-in 1 kA 6 A gL The voltage of the FA Z-... Circuit Breaker is limited to 300 V with this A uxiliary Switch installed. Shunt T rip R elease FA Z-X X A A -N NA € € € € Remote release for subsequent mounting onto FA Z-NA and FA Z-RT M odule width 1M U A dditional installation of standard auxiliary switch is possible Position indicator red - green Connection diagram 1 2 Technical Data FA Z-X X A A -N N A 12-11 10V A C FA Z-X X A A -N N A 110-44 15V A C Frequency Possible standard auxiliary switch FA Z-NA , FA Z-RT 12-110V A C 12-60V DC 50/60 Hz Z-NHK FA Z-NA , FA Z-RT 110-415V A C 110-230V DC 50/60 Hz Z-NHK M echanical Frame size Device height Device width M ounting Degree of protection, built-in Terminal protection Terminals Terminal capacity 1 and 2 W ires 45 mm 45 mm 105 mm 105 mm 17.5 mm (1M U) 17.5 mm (1M U) quick fastening with 2 lock-in positions on DIN rail EN 50022 IP40 IP40 finger and hand touch safe according to BGV A 3, ÖV E-EN 6 open mouthed/lift open mouthed/lift AW G 18-10 AW G 18-10 Electrical Can be mounted onto Operational voltage range 5,5 105 45 10 17,7 44 60 13 Technical Data Busbar • Design approved to UL 489 Electrical Rated voltage Rated current Short circuit strength Overvoltage category Impulse voltage strength Mechanical Busbar cross section Step distance Climatic stability Flame class acc. to UL Pollution degree 690 V 80 A < 25 kA III t 9.5 kV Z-SV/UL-16/.P-.TE/6 16 mm2 Cu 17.6 mm acc. to DIN EN 60068 V0/0.4 mm 2 Z-SV/UL-16/.P-.TE/12 5x17,6=88 5x17,6=88 11x17,6=193,6 17,6 17,6 5 1,5 5 A 46 46 A 32,5 32,5 A 15,5 A 100,4 206 15,5 Z-SV/UL-16/.P-.TE/18 17x17,6=299,2 17x17,6=299,2 17,6 1,5 46 5 32,5 Accessories Technical Data Busbar System 15,5 311,6 Lockout Attachment IS/SPE-1TE LOCK OFF ONLY .35 - .45 Nm (3 - 4 lb-in) 3 mm (1/8") OFF / O 5.0 - 7.0 mm Ø (3/16" - 9/32" Ø) MCB UL 489 Extension Terminal Z-EK/35/UL Z-EK/50/UL A A-A A-A 28,8 29,8 4 A 5,1 60 Ø13,5 10,5 18.5 A 12,3 12,4 40 17,75 A 6.8 3 28.5 +- 0.2 0 21 16 17,75 Attention! Only for Z-EK/35/UL ! 17,75 Moeller Gebäudeautomation KG Eugenia 1 A-3943 Schrems E-mail: sales.lowvoltage.systems@moeller.net Internet: www.moeller.at © 2005 by Moeller Gebäudeautomation Subject to alterations Printed by Buschek, Austria (11/05) Layout: Werbeweber, Schrems W0207+0075-7577GB Article No.: 104825 We keep power under control.