SERIES CB...BREAKERS MCCBs SERIES CB UL 489 OPTIONS FIELD KITS 15 Amp to 600 Amp • Auxiliary Contacts • Alarm Contact • Shunt Trip • UV Trip OPTIONS 25kA 35kA 50kA 100 Amp CB-1S 225 Amp CB-2S 25/50 kA Interruption Capacity OPTIONS • Open • Enclosed NEMA 1,3R,4,4X,12,7 400 Amp CB-4S 600 Amp CB-6S OPTION • MAGNETIC ONLY TRIP 50kA 480 Volt MOLDED CASE CIRCUIT BREAKERS 15 AMP THRU 600 AMP ELECTRICAL & ELECTRONIC CONTROLS, INC. 3881 DANBURY ROAD BREWSTER, NY 10509 845-278-5777, FAX 845-278-5444 www.eecontrols.com E-MAIL: info@eecontrols.com EECONTROLS, LTD 17 STEWART COURT ORANGEVILLE, ONTARIO CANADA L9W 3Z9 519-941-6845, FAX 519-940-0514 143 SERIES CB Circuit Breaker DESIGN Structure Series CB 2 1 3 6 4 5 1 Arc Extinguishers Arc extinguishers dissapate arcs that result when the circuit breaker interrupts current flow. Two arc chutes sets extinguish are in each phase for 2 Handle The handle position clearly indicates the contact status: closed, open or tripped. The handle indicates “ON” for safety when the contacts are closed. 3 Auxiliary Cover Auxiliary cover provides convenience when accessories are field installed and replaced. 4 Trip Button Trip button provides a manual means of exercising the mechanism by manu ally tripping the circuit breaker. 144 7 Trip Units Thermomagnetic 5 The function of the trip unit is to trip the operating mechanism in the event of a prolonged overload or short-circuit current. To accomplish this, thermal magnetic trip units are provided. Protection is provided by combining a temperature sensitive device with a current sensitive electro magnetic device. This magnetic trip is adjustable from 5X to 10X on Frame Size 2, 6 only. Operating Mechanism Trip Free Design Operating mechanism is to provide a means of opening and closing the circuit breaker. This mechanism is the quick-make, quick-break type and it is constructed so that all poles will make and break simultaneously when operated manually or automatically. This mechanism is also trip-free. Design - State of the Art For Current Limiting Breakers The moment of inertia of a rotating bridge is significantly lower than that of a breaker with a linear bridge. Therefore, the reaction to short circuit currents is much faster, which leads to better current limiting as well as shorter arc duration and substantially lower i2t values. The single axis of rotation provides both the fast short circuit reaction time as well as the normal switching func tion time. Branch circuit discrimination. Since the operation is fast, Series CB are excellent branch circuit protective devices, which can be used either as manual controllers with full (adjustable) motor protection or in conjunction with a contactor. Series CB provides good discrminiation from upstream circuit breakers or fuses as test oscillographs demonstrate. INDEX SERIES CB Circuit Breaker CONTENTS UL 489 LISTED Molded Case Circuit Breakers ••• Series CB Page Design ................................................................................. 144 146 High Capacity Trip #CB-*L (50kA).......... 147 Magnetic Only Trip #CB-*MCS (50kA)..... Contact Factory Selection Data .............Standard Trip #CB-*S (25kA)......... Accessories ......................................................................... 148 • Operator Handles................................................................ . 150 Dimensions ................................................................... 151, 152 MODERN SPACE SAVING DESIGNS! 100AF 225AF 400AF 600AF COMPARE TO THE OLD SWITCHGEAR BREAKERS OLD - VERY EXPENSIVE - VERY LARGE! 145 25kA IC CIRCUIT BREAKER SELECTION UL489 SERIES CB Circuit Breaker Order Information Standard Interruption Capacity 50kA 240V 25kA 480V STANDARD TRIP - 25kA, I.C. OPEN TYPE - THERMAL MAGNETIC 100 Amp Frame Series CB-1S 3 Pole Continuous Amps, Max. (In Thermal) Magnetic Instantaneous Trip - Amps Interruption Capacity kA (480V) Catalog No. Open Type List 15 20 30 40 50 60 80 100 500 500 500 500 500 600 800 1000 25 25 25 25 25 25 25 25 CB-1S-15A CB-1S-20A CB-1S-30A CB-1S-40A CB-1S-50A CB-1S-60A CB-1S-80A CB-1S-100A $398 $398 $398 $398 $398 $398 $455 $455 25 25 25 25 25 CB-2S-125A CB-2S-150A CB-2S-175A CB-2S-200A CB-2S-225A $988 $988 $988 $988 $988 25 25 25 25 CB-4S-250A CB-4S-300A CB-4S-350A CB-4S-400A $1600 $1600 $1600 $1600 UL489 225 Amp Frame Series CB-2S 3 Pole 125 150 175 200 225 Adjustable Magnetic 625A to 1250A Instantaneous adjustable, In x 5, 6, 7, 8, 9, 10. 400 Amp Frame Series CB-4S 3 Pole 250 300 350 400 2500 3000 3500 4000 I.C. 50kA at 240V, 25kA at 480V, 14kA at 600 Volt. 600 Amp Frame Series CB-6S 3 Pole 500 600 5000 6000 Check with Factory for 2 and 4 Pole Breakers. 25 25 CB-6S-500A CB-6S-600A $2200 $2200 I.C. 50kA at 240V, 25kA at 480V, 14kA at 600 Volt. ENCLOSED TYPE BREAKERS 4X NEMA 1/3R Add Add Suffix Extra Cost NEMA 4/12 Add Add Suffix Extra Cost NEMA 4X Add Add Suffix Extra Cost 15 to 60 Amp 80 - 100 Amp 125 - 150 Amp -3R -3R -3R $244 $244 $370 -4/12 -4/12 -4/12 $330 $330 $450 -4X -4X -4X $330 $330 $450 -7 -7 -7 $1,475 $1,560 $1,700 175 - 225 Amp 250 - 400 Amp 500 - 600 Amp -3R -3R -3R $540 $725 $960 -4/12 -4/12 -4/12 $620 $805 $1,040 -4X -4X -4X $620 $805 $1,040 -7 -7 -7 Check with Factory BREAKER Amp Rating 146 NEMA 7 Add Add Suffix Extra Cost $3,190 Discount Schedule CB UL489 50kA IC CIRCUIT BREAKER SELECTION SERIES CB Circuit Breaker Order Information High Interruption Capacity 100kA 240V 50kA 480V TRIP - 50kA, I.C. OPEN TYPE - THERMAL MAGNETIC 100 Amp Frame Series CB-1L 3 Pole Continuous Amps, Max. (In Thermal) Magnetic Instantaneous Trip - Amps Interruption Capacity kA (480V) Catalog No. Open Type List 15 20 30 40 50 60 80 100 500 500 500 500 500 600 800 1000 50 50 50 50 50 50 50 50 CB-1L-15A CB-1L-20A CB-1L-30A CB-1L-40A CB-1L-50A CB-1L-60A CB-1L-80A CB-1L-100A $599 $599 $599 $599 $599 $599 $665 $665 50 50 50 50 50 CB-2L-125A CB-2L-150A CB-2L-175A CB-2L-200A CB-2L-225A $1490 $1490 $1490 $1490 $1490 50 50 50 50 CB-4L-250A CB-4L-300A CB-4L-350A CB-4L-400A $2580 $2580 $2580 $2580 UL489 225 Amp Frame Series CB-2L 3 Pole 125 150 175 200 225 Adjustable Magnetic 625A to 1250A Instantaneous adjustable, In x 5, 6, 7, 8, 9, 10. 400 Amp Frame Series CB-4L 3 Pole 250 300 350 400 2500 3000 3500 4000 I.C. 100kA at 240V, 50kA at 480V, 22kA at 600 Volt. 600 Amp Frame Series CB-6L 3 Pole 500 600 5000 6000 50 50 CB-6L-500A CB-6L-600A $3470 $3470 I.C. 100kA at 240V, 50kA at 480V, 22kA at 600 Volt. CATALOG NUMBERING SYSTEM Typical 200 Amp, 3 Pole. Series CB 2 Breaker Series Breaker Frame CB CB CB CB MCS 25ka 35kA 50kA 1 2 4 6 S 100AF 225AF 400AF 600AF I.C. at 480V S 25kA L 50kA MCS 50kA MCS is Magnetic Trip (Instantaneous Trip only, no thermal trip) 200A SNT AC/DC 24V Rated Current 100AF 15A 20A 30A 40A 50A 60A 80A 100A 225AF 400AF 600AF Discount Schedule CB Catalog No.: CB-2S-200A Accessories 125A 150A 175A 200A 225A 250A 300A 350A 400A 500A 600A AS AL SNT UVT MI Auxiliary Switch Alarm Switch Shunt Trip Under voltage trip Mech. Interlock 147