-TWIN SERIES UL 489 LISTED MOLDED CASE CIRCUIT BREAKERS, EARTH LEAKAGE CIRCUIT BREAKERS 50A Frame ~ 800A Frame Max Voltage 480V USEH235 The new FUJI UL489 Molded Case Circuit Breaker and Earth Leakage Circuit Breaker ( -TWIN series) provides the ultimate in compact design, unprecedented value, and use anywhere in the world. 50A Frame 100A Frame 225A Frame 400A Frame 600/800A Frame MORE COMPACT (especially 50A Frame, 100A Frame, 225A Frame) than any breaker on the market, so control panels take up less space than ever before. Competitive pricing. Conformity to all WORLDWIDE STANDARDS, including UL / cUL / IEC / CE Marking / JIS. Fuji's -TWIN series 1) Suitable for branch circuit protection. gives you the features 2) Rated current of 3-800A, Max 480V. and flexibility you need: 3) Standard type and High interrupting capacities available in identically sized breakers. 4) Shunt trip (F), Under voltage release (R) and other accessories available. 5) Field installable in Screw, Flat, or Lug terminal constructions. 6) Auxiliary switch, Alarm switch, and Shunt trip can be installed in the field. 7) Choose Breaker-Mounted (N type) or Panel Door-Mounted (V type), Frange-Mounted (UF type), operating handles. 1 Table of Contents Page Specifications Part Number Construction Characteristic Curves Dimensions Internal Accessories External Accessories Dimensions of Operating Handles Wiring, Wire Sizes and Tightening Torque Flange Disconnect Handle <UF Type Handle> Terms & Conditions 3 8 9 11 18 22 23 25 26 30 2 Molded Case Circuit Breakers - NEW alpha-Twin, UL489 Listed SA/EA-UL Series Specifications Frame size (A) 50 Type SA52RCUL 100 SA53RCUL EA102CUL EA103CUL Appearance (with Screw Terminals, 3 pole) Rated insulation voltage (V) (IEC60947-2) AC 690 690 Rated voltage (V) (UL489) AC 240 240 Rated current (A) 3,5,10,15,20,30,40,50 Poles 2 Rated frequency (Hz) 50/60 50/60 480Y – – 480Y/277V – – 240V 14 14 – – 5/3 5/3 500V 7.5/4 7.5/4 440V 10/5 10/5 400V 10/5 10/5 230V 25/13 25/13 Rated UL489 interrupting CSA22-2 AC capacity sym (kA) IEC60947-2 AC 690V 600V [lcu/Ics] JIS C 8201-2 60,70,75,80,90,100 3 5/3 DC 250V 2 3 5/3 75 75 a 50 b 120 120 c 60 60 d 84 84 NONE L1 ● ● ● ● Lug Terminals L – Auxiliary switch W BZ6WR10CU BZ6W10CU BZ6WR10CU BZ6W10CU accessories Auxiliary switch for low current *4 Alarm switch WD BZ6WDR10CU BZ6WD10CU BZ6WDR10CU BZ6WD10CU K BZ6KR10CU BZ6K10CU BZ6KR10CU BZ6K10CU Alarm switch for low current KD BZ6KDR10CU BZ6KD10CU BZ6KDR10CU BZ6KD10CU Auxiliary & Alarm switch WK BZ6WKR10CU BZ6WK10CU BZ6WKR10CU BZ6WK10CU Auxiliary & Alarm switch WDKD BZ6WDKDR10CU BZ6WDKD10CU BZ6WDKDR10CU BZ6WDKD10CU Shunt trip F BZ6F10CU BZ6F10CU BZ6F10CU Dimensions (mm) a d c b Terminal Screw Terminals construction Flat Terminals Internal External BZ6F10CU 50 – Under voltage trip R BZ6R10CAU BZ6R10CAU BZ6R10CAU BZ6R10CAU Accessories with terminal block A *1 *1 *1 *1 Handle locking key, Cap type Q1 BZ6L10C BZ6L10C BZ6L10C BZ6L10C V BZ6V10C BZ6V10C BZ6V10C BZ6V10C N BZ6N10CP BZ6N10CP BZ6N10CP BZ6N10CP Field Installable Flat Terminal Kit Terminal Kit Lug Terminal Kit BZ-SU20B BZ-SU20B BZ-SU25B BZ-SU25B – – – – Terminal for screw, short type Provided Provided Provided Provided Covers *3 for screw, long type BZ6TB10C2U BZ6TB10C3U BZ6TB10C2U BZ6TB10C3U for Flat terminal – – – – for Lug terminal Insulation Barrier *2 – – – – BZ6B10C BZ6B10C BZ6B10C BZ6B10C 0.4 0.5 0.4 0.5 accessories External Operating Handle Mass (kg) (Screw Terminals) Notes: *1 For internal accessories with terminal block, specify "A" in the accessory P/N. When 50A Frame & 100A Frame are ordered w/UVT, the UVT is supplied with terminal block as standard. (see page 18, 19) *2 Insulation barriers are only required with flat terminal. *3 Short terminal covers are supplied as standard. If long terminal covers are required, please order BZ6TB10C2U or BZ6TB10C3U. *4 These internal accessories can be installed in the field. (see page 18, 19 for part number) ●: Available. –: Not available. 3 Molded Case Circuit Breakers - NEW alpha-Twin, UL489 Listed SA-UL Series Specifications Frame size (A) 100 Type SA102CUL 225 SA103CUL SA102RCUL SA103RCUL SA202CUL SA203CUL SA202RCUL SA203RCUL Appearance (with Screw Terminals, 3 pole) Rated insulation voltage (V) (IEC60947-2) AC 690 690 690 690 Rated voltage (V) (UL489) AC 240 480Y/277 240 240 480Y/277V Rated current (A) 15,20,30,40,50,60,70,75,80,90,100 15,20,30,40,50,60,70,75,80,90,100 125,150,175,200,225 125,150,175,20,225 Poles 2 2 2 Rated frequency (Hz) 50/60 50/60 50/60 50/60 480Y – – – – 480Y/277V – 25 – – 25 240V 35 85 35 35 85 – – – – Rated UL489 interrupting CSA22-2 AC capacity sym (kA) IEC60947-2 AC 690V 600V [lcu/Ics] JIS C 8201-2 a 3 – – – 15/4 30/8 15/4 15/4 440V 25/7 50/13 25/7 25/7 400V 30/8 50/13 30/8 30/8 230V 50/25 100/50 50/25 50/25 15/8 40/20 15/8 15/8 a 90 90 105 105 b 155 155 165 165 c 60 60 60 60 d 82 82 84 84 NONE ● ● ● ● ● ● ● ● ● d c 3 Lug Terminals L ● ● ● Auxiliary switch W BZ6WR30CU BZ6W30CU BZ6W30CU BZ6W30CU BZ6W40CU BZ6W40CU BZ6W40CU BZ6W40CU Screw Terminals L1 construction Flat Terminals Internal 3 – b Terminal 2 500V DC 250V Dimensions (mm) 3 accessories Auxiliary switch for small current WD *3 Alarm switch K BZ6WDR30CU BZ6WD30CU BZ6WD30CU BZ6WD30CU BZ6WD40CU BZ6WD40CU BZ6WD40CU BZ6WD40CU Alarm switch for small current KD BZ6KDR30CU BZ6KD30CU BZ6KD30CU BZ6KD30CU BZ6KD40CU BZ6KD40CU BZ6KD40CU BZ6KD40CU Auxiliary & Alarm switch WK BZ6WKR30CU BZ6WK30CU BZ6WK30CU BZ6WK30CU BZ6WK40CU BZ6WK40CU BZ6WK40CU BZ6WK40CU Auxiliary & Alarm switch WDKD BZ6WDKDR30CU BZ6WDKD30CU BZ6WDKD30CU BZ6WDKD30CU BZ6WDKD40CU BZ6WDKD40CU BZ6WDKD40CU BZ6WDKD40CU Shunt trip F BZ6F30CU BZ6F30CU BZ6F40CU BZ6F40CU Under voltage trip R ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ Accessories with terminal block A *1 *1 *1 *1 *1 *1 *1 *1 Handle locking key, Cap type Q1 BZ6L30C BZ6L30C BZ6L30C BZ6L30C BZ6L40C BZ6L40C BZ6L40C BZ6L40C V BZ6V30C BZ6V30C BZ6V30C BZ6V30C BZ6V40C BZ6V40C BZ6V40C BZ6V40C N BZ6N30CP BZ6N30CP BZ6N30CP BZ6N30CP BZ6N40CP BZ6N40CP BZ6N40CP BZ6N40CP Field Installable Flat Terminal Kit Terminal Kit Lug Terminal Kit BZ6SU35B BZ6SU35B BZ6SU35B BZ6SU35B BZ6SU50B BZ6SU50B BZ6SU50B BZ6SU50B BZ6TA100 BZ6TA100 BZ6TA100 BZ6TA100 BZ6TA225 BZ6TA225 BZ6TA225 BZ6TA225 Terminal for screw, short type BZ-TS30B-3 BZ-TS30B-3 BZ-TS30B-3 BZ-TS30B-3 BZ-TS40B BZ-TS40B BZ-TS40B BZ-TS40B Covers for screw, long type BZ-TB30B-3 BZ-TB30B-3 BZ-TB30B-3 BZ-TB30B-3 BZ-TB40B BZ-TB40B BZ-TB40B BZ-TB40B for Flat terminal BZ-TL30B-3 BZ-TL30B-3 BZ-TL30B-3 BZ-TL30B-3 BZ-TL40B BZ-TL40B BZ-TL40B BZ-TL40B BZ-TB30B-3 BZ-TB30B-3 BZ-TB30B-3 BZ-TB30B-3 BZ-TB40B BZ-TB40B BZ-TB40B BZ-TB40B External accessories External Operating Handle for Lug terminal Insulation Barrier *2 Mass (kg) (Screw Terminals) BZ6KR30CU BZ6K30CU BZ6K30CU BZ6K30CU BZ6F30CU BZ6F30CU BZ6K40CU BZ6K40CU BZ6K40CU BZ6K40CU BZ6F40CU BZ6F40CU BZ6B30CU BZ6B30CU BZ6B30CU BZ6B30CU BZ6B40CU BZ6B40CU BZ6B40CU BZ6B40CU 1.1 1.2 1.1 1.2 1.1 1.3 1.1 1.3 Notes: *1 For internal accessories with terminal block, specify "A" in the accessory P/N. (see page 18, 19) *2 Insulation barriers are only required with flat terminal. *3 These internal accessories can be installed in the field. (see page 18, 19 for part number) ●: Available. –: Not available. ▲: Factory-mounted accessory. 4 Molded Case Circuit Breakers - NEW alpha-Twin, UL489 Listed SA-UL Series Specifications Frame size (A) 400 Type SA402CUL SA403CUL SA402RCUL SA403RCUL 600 800 SA603RCUL SA803RCUL Appearance (with Screw Terminals, 3 pole) Rated insulation voltage (V) (IEC60947-2) AC 690 690 690 690 Rated voltage (V) (UL489) AC 240 480 480 480 Rated current (A) 250,300,350,400 250,300,350,400 500,600 700,800 Poles 2 2 3 3 Rated frequency (Hz) 50/60 50/60 50/60 50/60 480Y 25 50 50 50 480Y/277V 25 50 50 50 240V 42 85 85 85 – – – – – 30/15 30/15 30/15 500V 22/11 35/18 35/18 35/18 440V 35/18 50/25 50/25 50/25 400V 35/18 50/25 50/25 50/25 230V 50/25 85/43 85/43 85/43 20 40/20 40/20 40/20 a 140 140 210 210 b 257 257 275 275 c 103 103 103 103 d 146 146 146 146 NONE – – – – ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ● ● ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ● ● ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ● ● ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ Rated UL489 interrupting CSA22-2 AC capacity sym (kA) IEC60947-2 AC 690V 600V [lcu/Ics] JIS C 8201-2 DC 250V Dimensions (mm) a d c b Terminal Screw Terminals ● L ● Lug Terminals W ▲ Auxiliary switch Internal ▲ accessories Auxiliary switch for small current WD K ▲ Alarm switch ▲ Alarm switch for small current KD WK ▲ Auxiliary & Alarm switch WDKD ▲ Auxiliary & Alarm switch F ▲ Shunt trip R ▲ Under voltage trip construction Flat Terminals External 3 L1 Accessories with terminal block A *1 *1 *1 *1 *1 *1 Handle locking key, Cap type Q1 ▲ ▲ ▲ ▲ ▲ ▲ V BZ6V60C BZ6V60C BZ6V60C BZ6V60C BZ6V70C BZ6V70C N BZ6N60CP BZ6N60CP BZ6N60CP BZ6N60CP BZ6N70CP BZ6V70CP BZ-SU60B BZ-SU60B BZ-SU60B BZ-SU60B BU-SU70B-600 BZ-SU70B-800 BZ6TA350 BZ6TA350 BZ6TA350 BZ6TA350 BZ-TA600 BZ-TA700 (700A) (up to 350A) (up to 350A) (up to 350A) (up to 350A) BZ6TA400 BZ6TA400 BZ6TA400 BZ6TA400 accessories External Operating Handle Field Installable Flat Terminal Kit Terminal Kit Lug Terminal Kit BZ-TA800 (800A) (400A) (400A) (400A) (400A) Terminal Covers BZ-TB60B BZ-TB60B BZ-TB60B BZ-TB60B BZ-TB70B BZ-TB70B Insulation Barrier B-43A B-43A B-43A B-43A B-43A B-43A 4.5 5 4.5 5 9 10 Mass (kg) (Screw Terminals) Notes: *1 For internal accessories with terminal block, specify "A" in the accessory P/N. (see page 18, 19) ●: Available. –: Not available. ▲: Factory-mounted accessory. 5 3 Earth Leakage Circuit Breakers - NEW alpha-Twin, UL489 Listed SG/EG-UL Series Specifications Frame size (A) 50 100 Type SG53RCUL EG102CUL EG103CUL SG103CUL Appearance (with Screw Terminals, 3 pole) Rated insulation voltage (V) (IEC60947-2) AC 440 440 440 440 Rated voltage (V) (UL489) AC 240 240 240 240 Rated current (A) 3, 5, 10, 15, 20, 30,40,50 60,70,75,80,90,100 60,70,75,80,90,100 32,40, 50, 65, 75, 100 Rated Sensitive Current (mA) 30, 100/200/500 30, 100/200 30, 100/200/500 30, 100/200/500 Poles 3 2 3 3 Rated frequency (Hz) 50/60 50/60 50/60 50/60 – – – – 480Y/277V – – – – 240V 14 14 14 35 – – – – 10/5 – 10/5 25/7 415V 10/5 – 10/5 25/7 380V 10/5 – 10/5 25/7 230V 25/13 10/5 25/13 50/13 100V 25/13 10/5 25/13 50/13 a 75 75 75 90 b 120 120 120 155 c 60 60 60 60 d 84 84 84 82 NONE ● ● ● ● ● L1 ● ● Lug Terminals L – – – – Auxiliary switch W BZ6Wm10CU BZ6Wm10CU BZ6Wm10CU BZ6Wm30CU K BZ6Km10CU BZ6Km10CU BZ6Km10CU BZ6Km30CU F BZ6Fm10CAU BZ6Fm10CAU BZ6Fm10CAU R BZ6Rm10CAU BZ6Rm10CAU BZ6Rm10CAU ▲ ▲ Rated UL489 interrupting CSA22-2 AC 480Y capacity sym (kA) AC 500V 440V IEC60947-2 [lcu/Ics] Dimensions (mm) DC d c a b Terminal Screw Terminals construction Flat Terminals Internal accessories Alarm switch *4 Shunt trip Under voltage trip Accessories with terminal block A External – *1 *1 *1 *1 Q1 BZ6L10C BZ6L10C BZ6L10C BZ6L30C V BZ6V10C BZ6V10C BZ6V10C BZ6V30C N BZ6N10CP BZ6N10CP BZ6N10CP BZ6N30CP Field Installable Flat Terminal Kit Terminal Kit Lug Terminal Kit BU-SU20B BU-SU20B BU-SU20B BZ6SU35B – – – BZ6TA100 Terminal for screw, short type Provided Provided Provided BZ-TS30B-3 Covers *3 for screw, long type BZ6TB10C3U BZ6TB10C3U BZ6TB10C3U BZ-TB30B-3 for Flat terminal – – – BZ-TL30B-3 for Lug terminal Insulation Barrier *2 – – – – BZ6TB10C BZ6TB10C BZ6TB10C BZ6B30CU 0.6 0.6 0.6 1.5 Handle locking key, Cap type accessories External Operating Handle Mass (kg) (Screw Terminals) Notes: *1 For internal accessories with terminal block, specify "A" in the accessory P/N. When 50A Frame & 100A Frame are ordered w/UVT, the UVT is supplied with terminal block as standard. (see page 18, 19) *2 Insulation barriers are only required with flat terminal. *3 Short terminal covers are supplied as standard. If long terminal covers are required, Please order BZ6TB10C2U or BZ6TB10C3U. *4 These internal accessories can be installed in the field. (see page 18, 19 for part number) ●: Available. –: Not available. ▲: Factory-mounted accessory. 6 Earth Leakage Circuit Breakers - NEW alpha-Twin, UL489 Listed SG-UL Series Specifications Frame size (A) 225 400 Type SG203CUL SG403CUL Appearance (with Screw Terminals, 3 pole) Rated insulation voltage (V) (IEC60947-2) AC 440 440 Rated voltage (V) (UL489) AC 240 240 Rated current (A) 125, 150, 175, 200, 225 250, 300, 350, 400 Rated Sensitive Current (mA) 30, 100/200/500 30, 100/200/500 Poles 3 3 Rated frequency (Hz) 50/60 50/60 – – 480Y/277V – – 240V 35 35 – – 25/7 35/18 415V 25/7 35/18 380V 25/7 35/18 230V 50/13 50/25 100V 50/13 50/25 a 105 140 b 165 257 c 60 103 d 84 146 NONE ● – L1 – ● Lug Terminals L – – Auxiliary switch W BZ6Wm40CU K BZ6Km40CU Shunt trip F Under voltage trip R ▲ ▲ ▲ ▲ ▲ ▲ Accessories with terminal block A Rated UL489 interrupting CSA22-2 AC 480Y capacity sym (kA) AC 500V 440V IEC60947-2 [lcu/Ics] Dimensions (mm) DC d c a b Terminal Screw Terminals construction Flat Terminals Internal accessories Alarm switch External *1 *1 Q1 BZ6L40C ▲ V BZ6V40C BZ6V60C N BZ6N40CP BZ6N60CP Field Installable Flat Terminal Kit Terminal Kit Lug Terminal Kit BZ6SU50B – BZ6TA225 – Terminal for screw, short type BZ-TS40B – Covers for screw, long type BZ-TB40B BZ-TB60B for Flat terminal BZ-TL40B – – – BZ6B40CU B-43A 1.5 5.6 Handle locking key, Cap type accessories External Operating Handle for Lug terminal Insulation Barrier Mass (kg) (Screw Terminals) Notes: *1 For internal accessories with terminal block, specify "A" in the accessory P/N. (see page 18, 19) ●: Available. –: Not available. ▲: Factory-mounted accessory. 7 Molded Case Circuit Breakers - NEW alpha-Twin, UL489 Listed SA-UL Series Earth Leakage Circuit Breakers - NEW alpha-Twin, UL489 Listed SG-UL Series Part Number SA-UL; MCCB SA103CUL / 100 L1 Q1 Product category Handle locking cover for lockout (Cap type) Rated current (A) Cap type (Q1) is applicable for 400-800A Frame. For 225A Frame or smaller, order the Handle Lock cover separately Terminal structure Terminal construction for SA-UL series Code Line side Load side SA52RCUL, SA53RCUL EA102CUL, EA103CUL SA102CUL, SA103CUL SA102RCUL, SA103RCUL SA202CUL, SA203CUL SA203RCUL, SA203RCUL – – – – ● ● ● ● ● ● ● None – – ● L Lug Lug – L1 Flat Flat ● ● ● ● SG103CUL / 100 – 30MA SA402CUL, SA403CUL SA402RCUL, SA403RCUL SA603RUL SA803RUL/700 SA803RUL/800 – SA-UL; ELCB L1 Q1 Product category Rated current (A) Handle locking cover for lockout (Cap type) Rated sensitive current (mA) Code Line side 2 poles CO 100/200mA changeable ● ● CO 100/200/500mA changeable – 30MA 30mA Cap type (Q1) is applicable for 400-800A Frame. For 225A Frame or smaller, order the Handle Lock cover separately 3 poles ● – ● Terminal structure Code Line side Load side SG53RCUL, EG103CUL None – – L1 Flat Flat SG103CUL ● ● SG203CUL ● ● SG403CUL ● ● – ● ACCESSORIES For up to 225AF - Auxiliary switches & Alarm switches BZ6 WK L 30C A U Product category UL listed Type of accessory W; Auxiliary switch WD; Auxiliary switch (for Small current) K; Alarm switch KD; Alarm switch (for Small current) Method of connection. None; Lead wire A; with terminal block Applicable frame size 10C; 50AF, 100AF(EA&EG10_CUL) 30C; 100AF 40C; 225AF Installation, L; Left side of the breaker R; Right side of the breaker - Shunt trip & Undervoltage trip devices BZ6 F S 30C A U Product category UL listed Type of accessory F; Shunt trip device R; Undervoltage trip device Method of connection. None; Lead wire A; with terminal block Operating voltage, For details, see page 18, 19. Applied frame size 10C; 50AF, 100AF(EA&EG10_CUL) 30C; 100AF 40C; 225AF 8 Characteristic Curves ● SA52RCUL, SA53RCUL, SG53RCUL (Rated current: 5A, 10A, 40A) ● SA52RCUL, SA53RCUL, SG53RCUL (Rated current: 3A, 15A, 20A, 30A, 50A) 180 120 60 40 20 10 6 4 Minutes Max. value 2 Min. value 1 0.6 0.4 Reference temp. 40˚C 400 0.1 0.06 0.04 0.02 1 1.5 2 350 300 200 150 100 10 20 30 40 Ambient temp. (˚C) Minutes Max. value 2 1 40 1 40 Operating time Seconds 20 Instantaneous tripping 960% to 1440% Min. value Reference temp. 40˚C 400 0.2 0.02 1 1.5 2 350 0 10 20 30 40 Instantaneous tripping 800% to 1200% Min. value 1 0.6 0.4 0.2 150 Max. value Reference temp. 40˚C 400 0.02 100 0 10 20 30 40 0.01 50 Ambient temp. (˚C) 1 1.5 2 350 300 250 200 150 100 50 -10 3 4 5 6 7 8 10 15 20 30 40 5060 80100 Multiple of rated current 0 10 20 30 40 Ambient temp. (˚C) ● SA202CUL, SA203CUL, SA202RCUL, SA203RCUL 180 120 60 40 Minutes 20 10 6 4 (40 to 100A) Max. value 20 10 6 4 2 2 1 40 1 40 (15 to 30A) 2 0.2 Reference temp. 40˚C Max. total fault clearing time 0.1 0.06 0.04 0.02 Rated current Correction ratio (%) 1 Instantaneous tripping 0.6 800% to 1500% 0.4 150 3 4 5 6 7 8 10 15 20 30 40 5060 80100 Multiple of rated current Max. value 20 10 6 4 Min. value Instantaneous tripping 800% to 1400% 2 1 0.6 0.4 Reference temp. 40˚C 0.2 Max. total fault clearing time 0.1 0.06 0.04 100 40 to 100A 0.02 50 1 1.5 2 15 to 30A (32A) Operating time Seconds 20 10 6 4 Min. value 50 Ambient temp. (˚C) 2 0.1 0.06 0.04 180 120 60 40 0.01 100 50 -10 3 4 5 6 7 8 10 15 20 30 40 5060 80100 Multiple of rated current 10 6 4 250 200 50 -10 3 4 5 6 7 8 10 15 20 30 40 5060 80100 Multiple of rated current 250 200 150 20 300 ● SA102CUL, SA103CUL, SA102RCUL, SA103RCUL Minutes 10 6 4 2 2 1 1.5 2 350 300 ● EA102CUL, EA103CUL, EG102CUL, EG103CUL (Rated current: 100A) (Rated current: 80A, 90A, 100A) 20 Operating time Correction ratio (%) Minutes Operating time Seconds 0.01 50 20 1 0.6 0.4 Reference temp. 40˚C 400 0.02 0 180 120 60 40 10 6 4 Min. value 1 0.6 0.4 180 120 60 40 0.1 0.06 0.04 Operating time Seconds 2 0.1 0.06 0.04 ● EA102CUL, EA103CUL, EG102CUL, EG103CUL (Rated current: 60A, 75A) 10 6 4 Instantaneous tripping 800% to 1200% 0.2 250 50 -10 3 4 5 6 7 8 10 15 20 30 40 5060 80100 Multiple of rated current 10 6 4 Operating time Correction ratio (%) 2 20 Operating time Correction ratio (%) Operating time Seconds Instantaneous tripping 960% to 1440% Operating time Correction ratio (%) Operating time Seconds 10 6 4 0.01 Max. value 1 40 20 0.2 9 10 6 4 2 1 40 0.01 20 0 10 20 30 40 Ambient temp. (˚C) 50 0.01 Rated current Correction ratio (%) Minutes 180 120 60 40 150 100 50 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100 Multiple of rated current 0 10 20 30 40 Ambient temp. (˚C) 50 50 Characteristic Curves ● SG103CUL ● SG203CUL 180 120 60 40 10 6 4 Max. value 2 1 40 1 40 10 6 4 Min. value Instantaneous tripping 800% to 1500% 2 1 0.6 0.4 Reference temp. 40˚C Max. total fault clearing time 0.02 40 to 100A 0 10 20 30 40 2 1 0.6 0.4 0.01 50 Ambient temp. (˚C) Reference temp. 40˚C Max. total fault clearing time 150 100 50 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100 Multiple of rated current 0 10 20 30 40 50 Ambient temp. (˚C) ● SG403CUL 180 120 60 40 10 6 4 Max. value 20 10 6 4 2 1 40 1 40 20 Min. value 10 6 4 2 Instantaneous tripping 800% to 1400% 0.2 Max. total fault clearing time 0.1 0.06 0.04 0.02 Reference temp. 40˚C Rated current Correction ratio (%) 1 0.6 0.4 150 20 10 6 4 2 Instantaneous tripping 800% to 1400% 1 0.6 0.4 Max. total fault clearing time 0.02 3 4 5 6 7 8 10 15 20 30 40 50 70 100 Multiple of rated current 0 10 20 30 40 0.01 50 Reference temp. 40˚C 150 100 50 1 1.5 2 Ambient temp. (˚C) 3 4 5 6 7 8 10 15 20 30 40 50 70 100 Multiple of rated current 0 10 20 30 40 50 Ambient temp. (˚C) ● SA803RCUL 180 120 60 40 Minutes 180 120 60 40 20 10 6 4 Max. value 20 10 6 4 2 1 40 1 40 20 Min. value 2 Instantaneous tripping 800% to 1300% 0.2 Max. total fault clearing time 0.1 0.06 0.04 0.02 Reference temp. 40˚C Rated current Correction ratio (%) 1 0.6 0.4 150 3 4 5 6 7 8 10 15 20 30 40 50 70 100 Multiple of rated current Max. value 20 10 6 4 Min. value 2 Instantaneous tripping 600% to 1000% 1 0.6 0.4 0.2 Max. total fault clearing time 0.1 0.06 0.04 100 0.02 50 1 1.5 2 Operating time Seconds 2 0.01 Min. value 0.1 0.06 0.04 100 ● SA603RCUL 10 6 4 Max. value 0.2 50 1 1.5 2 Operating time Seconds 2 Rated current Correction ratio (%) Minutes 20 0.01 Instantaneous tripping 800% to 1400% Min. value 0.02 3 4 5 6 7 8 10 15 20 30 40 5060 80100 Multiple of rated current 180 120 60 40 Minutes 10 6 4 0.2 ● SA402CUL, SA403CUL, SA402RCUL, SA403RCUL Operating time Seconds 20 0.1 0.06 0.04 100 50 1 1.5 2 32A Max. value 0 10 20 30 40 Ambient temp. (˚C) 50 0.01 Reference temp. 40˚C Rated current Correction ratio (%) 0.01 150 Operating time Seconds 20 0.1 0.06 0.04 Minutes 10 6 4 2 0.2 Operating time Seconds 20 Rated current Correction ratio (%) Minutes 20 Rated current Correction ratio (%) Operating time Seconds Minutes 180 120 60 40 150 100 50 1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 70 100 Multiple of rated current 0 10 20 30 40 50 Ambient temp. (˚C) 10 Dimensions unit: inch (mm) ● SA52RCUL/, SA53RCUL/, SG53RCUL/, EA102CUL/, EA103CUL/, EG102CUL/, EG103CUL/ 3 pole 2 pole (EG102CUL) 0.669 (17) Trip button 50A Frame: M5x14 100A Frame: M8x15 0.315 (8) 0.327 (8.3) 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) Breaker 3.307 (84) 3.307 (84) 3.937 (100) 1.969 (50) 0.945 (24) 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) Breaker 3.307 (84) 0.386 (9.8) 0.098 (2.5) 1.693 (43) ON 1.654 (42) 3.307 (84) 2.008 (51) 0.193 dia (Ø4.9) 1.575 (40) Mounting hole 3.937 (100) 1.969 (50) 1.575 (40) 1.654 (42) Terminal cover 0.386 (9.8) Terminal cover Mounting hole 0.307 dia (Ø7.8) 2 pole 0.945 (24) 0.386 (9.8) 1.969 (50) 2.953 (75) 0.386 (9.8) 0.984 (25) Trip button 0.984 (25) 1.969 (50) 2.008 (51) 2.362 (60) 0.157 (4) 0.315 (8) 3.307 (84) ● SA52RCUL/L1, SA53RCUL/L1, SG53RCUL/L1 2 pole 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) Breaker 3.307 (84) 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) Breaker 3.307 (84) 1.969 (50) 3.307 (84) 1.654 (42) 0.098 (2.5) 0.193 dia (Ø4.9) 1.969 (50) 0.276 (7) 1.575 (40) 1.811 (46) 1.693 (43) ON Trip button 0.984 (25) Trip button M5x16 0.453 (11.5) M5x16 0.307 dia (Ø7.8) Insulation barrier 0.650 (16.5) Mounting hole 1.969 (50) 3.937 (100) 3.307 (84) 1.654 (42) 1.969 (50) 1.575 (40) 0.650 (16.5) 0.276 (7) Insulation barrier 3.937 (100) 3 pole Mounting hole 0.453 (11.5) 0.079 (2) 1.024 (26) 0.984 (25) 1.969 (50) 0.315 (8) 1.969 (50) 2.953 (75) 2.008 (51) 0.157 (4) 2.362 (60) 3.307 (84) ● EA102CUL/L1, EA103CUL/L1, EG102CUL/L1, EG103CUL/L1 3 pole 2 pole (EG102CUL) 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) 3.973 (100) 1.969 (50) 3.307 (84) Trip button M8x22 1.969 (50) 2.362 (60) 2.953 (75) 11 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) Breaker 0.984 (25) Trip button 0.709 (18) 3.307 (84) Breaker ON 24 0.098 (2.5) 3.307 (84) 1.811 (46) 1.693 (43) 0.193 dia (Ø4.9) 1.969 (50) 0.354 (9) 0.307 dia (Ø7.8) Insulation barrier 0.728 (18.5) Mounting hole 1.575 (40) 1.969 (50) 3.973 (100) 3.307 (84) 1.654 (42) 1.969 (50) 1.575 (40) 0.728 (18.5) 0.354 (9) Insulation barrier 1.654 (42) Mounting hole 2 pole 0.709 (18) M8x22 0.157 (4) 1.102 (28) 0.984 (25) 1.378 (35) 1.969 (50) 0.315 (8) 0.157 (4) 2.008 (51) 2.362 (60) 3.307 (84) Dimensions unit: inch (mm) ● SA102CUL/, SA103CUL/, SA102RCUL/, SA103RCUL/ 2.205 (56) 0.059 (1.5) 0.164-32 tap or 0.197 dia hole (M4 or Ø5) Breaker R0 .0 0.177 dia (Ø4.5) [R or les s 5.197 (132) 0.669 (17) 0.945 (24) Terminal section Max 0.65 (16.5) ON 6.102 (155) 5.315 (135) 0.65 (16.5) 4.016 (102) 1.969 (50) 0.866 (22) 78 2] 1.850 (47) Cross recessed head screw M8X14 0.335 (8.5) RC: 2.283 (58) C: 1.969 (50) 2.283 (58) 0.394 (10) 0.335 dia (Ø8.5) Insulation barrier 2.047 (52) or more 3.346 (85) 1.358 (34.5) Mounting hole 1.181 (30) 0.354 dia (Ø9) 0.315 (8) 3.425 (87) or more Trip button Panel drilling 0.079 (2) 2.362 (60) Front panel cutting Connecting bus bar size 2.362 (60) 0.236 (6) 3.543 (90) Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. 3.228 (82) ● SG103CUL/ 2.205(56) Interphase barrier 0.335dia(Ø8.5) 2.283(58) Residual breaking indicator 3.346(85) Sensitive current selective switch 1.358(34.5) 0.164-32 Tap or 0.197 Diameter (M4 or Ø5) (Change over type) 1.969(50) Mounting hole P.C.B box (Power) 1.850(47) Breaker R0 2.047 (52) or more 0.177dia(Ø4.5) 0.059(1.5) .0 78 [R 2] 0.492(12.5) or les s 0.039(1) 2.008(51) 2.362(60) 0.531(13.5) 0.236(6) 0.079(2) 3.228(82) 5.197(132) 6.102(155) 4.016(102) 5.315(135) 1.969(50) 3.701(94) ON 0.866(22) 2.362(60) 3.425 (87) or more 1.181 (30) Trip button Test button Front panel cutting Panel drilling Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. 3.543(90) ● SA102CUL/L1, SA103CUL/L1, SA102RCUL/L1, SA103RCUL/L1 2.205 (56) 2.283 (58) Insulation barrier RC: 2.283 (58) C: 1.969 (50) 0.059 (1.5) 1.102 (28) 0.157 (4) 0.164-32 tap or 0.197 dia hole (M4 or Ø5) Breaker R0 2.047 (52) or more 3.346 (85) 2.362 (60) 1.358 (34.5) 0.335 dia (Ø8.5) Mounting hole ON 0.335 (8.5) 0.807 (20.5) 0.157 (4) 1.102 (28) 3.543 (90) M8x22 0.079 (2) [R 2] or les s 1.181 (30) Trip button 0.669 (17) 78 5.197 (132) 6.102 (155) 5.315 (135) 4.016 (102) 0.65 (16.5) 1.969 (50) 0.866 (22) 0.177 dia (Ø4.5) .0 1.850 (47) Panel drilling 3.425 (87) or more Front panel cutting 2.362 (60) 0.236 (6) 3.228 (82) Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. 12 Dimensions unit: inch (mm) ● SA102CUL/L, SA103CUL/L, SA102RCUL/L, SA103RCUL/L 2.205 (56) 2.283 (58) Insulation barrier Breaker R0 ON 0.315 (8) 78 [R 2] or les s 5.197 (132) 1.850 (47) 1.181 (30) Trip button 0.650 (16.5) 2.047 (52) or more RC: 2.283 (58) C: 1.969 (50) 0.164-32 tap or 0.197 dia hole (M4 or Ø5) 1.828 (46.42) .0 6.102 (155) 5.315 (135) 0.65 (16.5) 4.016 (102) 1.969 (50) 0.866 (22) 0.059 (1.5) 0.177 dia (Ø4.5) 3.346 (85) 2.362 (60) 1.358 (34.5) 0.335 dia (Ø8.5) Mounting hole 0.669 (17) 1.828 (46.42) 0.236 (6) 0.079 (2) 3.543 (90) 3.425 (87) or more Panel drilling 2.362 (60) 3.228 (82) Front panel cutting Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. ● SA202CUL/, SA203CUL/, SA202RCUL/, SA203RCUL/ 0.335Dia. (Ø8.5) 4.961 (126) 1.380 (35) 0.079 (2) 0.354 dia (Ø9) 0.236 (6) 0.315 (8) 4.016 (102) or more Connecting bus bar size Front panel cutting Panel drilling 2.756 (70) 0.945 (24) Terminal section Trip button 2.205 (56) Hexagonal head bolt M8X20 0.433 (11) 1.004 (25.5) Max 0.984 (25) 1.969 (50) 4.016 (102) 5.669 (144) ON 6.496 (165) s les or 2) (R 1.850 (47) 0.866 (22) Breaker 2.047 (52) or more Breaker 0.177Dia. (ø4.5) Mounting hole 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) 78 .0 R0 RC: 3.543 (90) C: 3.150 (80) 0.039 (1) 0.413 (10.5) 2.303 (58.5) Insulation barrier Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. 2.362 (60) 0.236 (6) 3.937 (100) 3.307 (84) 4.134 (105) ● SG203CUL/ Residual breaking indicator Mounting hole Breaker .0 P.C.B box (Power) 78 2 [R ]o rl 1.850 (47) es 0.492 (12.5) s 0.866 (22) 1.004 (25.5) 0.413 (10.5) 0.335 dia.(Ø8.5) 0.164-32 Tap or 0.197 Diameter (M4 or Ø5) R0 0.177 dia.(Ø4.5) Sensitive current selective switch (Change over type) 1.378 (35) 2.047 (52) or more 2.756 (70) Interphase barrier 2.303(58.5) 3.150 (80) 2.205(56) 0.039(1) Hexagon socket head bolt M8x16 0.039 (1) 2.008 (51) 2.362 (60) 3.307(84) 13 0.236 (6) 0.079 (2) 0.827 (21) Trip button 3.937 (100) 4.134 (105) 0.433 (11) 4.9621 (126) 6.496 (165) 5.669 (144) 4.016 (102) 3.701 (94) 1.969 (50) ON 1.380 (35) Screw terminal 4.061 (102) or more Test button Panel drilling Front panel cutting 0.945 (24) Dimensions unit: inch (mm) ● SA202CUL/L1, SA203CUL/L1, SA202RCUL/L1, SA203RCUL/L1 2.756 (70) Breaker 4.961 (126) 1.969 (50) 5.669 (144) 4.016 (102) ON Breaker s les or 2) (R 1.850 (47) 0.866 (22) 6.496 (165) 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) 0.177dia.(Ø4.5) Mounting hole 0.039 (1) 1.181 (30) 0.236 (6) 2.047 (52) or more 0.335 dia (Ø8.5) 2.303 (58.5) 78 .0 R0 RC: 3.543 (90) C: 3.150 (80) Insulation barrier Trip button 2.205 (56) 0.984 (25) 0.394 (10) 1.380 (35) 0.787 (20) 3.937 (100) 4.134 (105) 0.236 (6) 1.181 (30) 0.236 (6) M8x22 0.079 (2) 4.016 (102) or more Front panel cutting Panel drilling 2.362 (60) 3.307 (84) Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. ● SA202CUL/L, SA203CUL/L, SA202RCUL/L, SA203RCUL/L 2.756 (70) 2.047 (52) or more Breaker 4.961 (126) 0.177 dia (Ø4.5) ON 1.969(50) 5.669 (144) 4.016 (102) 6.496 (165) 0.164-32 Tap or 0.197 dia hole (M4 or Ø5) Breaker 1.850 (47) 0.866 (22) 0.039 (1) s les or 2) (R 0.335 dia (Ø8.5) Mounting hole 2.303 (58.5) 1.811 (46) 78 .0 R0 RC: 3.543 (90) C: 3.150 (80) Insulation barrier Trip button 2.205 (56) 0.236 (6) 0.984 (25) 3.937 (100) 4.134 (105) 0.413 (10.5) 1.457 (37) 1.380 (35) 0.079 (2) 4.016 (102) or more Front panel cutting Panel drilling 1.811 (46) 2.362 (60) 3.307 (84) Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. ● SA402CUL/L1, SA403CUL/L1, SA402RCUL/L1, SA403RCUL/L1, SG403CUL/L1 Insulation barrier 1.732 (44) 1.732 (44) 2.205 (56) 2.205 (56) 5.315 (135) 3.622 (92) or more 8.858 (225) 3.307 (84) #1/4-20 Tap or 0.276 dia hole (M6 or Ø7) R0 .0 78 (R 2) or Breaker 0.315 (8) ON Breaker le ss 0.315 (8) 1.594 (40.5) M12x35 0.965 (24.5) 2.087 (53) 0.591 (15) 3.543 (90) 4.016 (102) Trip button 10.118 (257) 2.008 (51) 1.732 (44) 8.425-8.504 (214-216) 0.984 (25) 0.315 dia (Ø8) Mounting hole 0.531 dia (Ø13.5) 1.594 (40.5) 4.134 (105) 5.394 (137) 1.732 (44) 1.732 (44) Panel drilling 5.394 (137) or more Front panel cutting 3.72 (94.5) 4.055 (103) 0.177 (4.5) Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. 4.213 (107) 14 Dimensions unit: inch (mm) ● SA402CUL/L, SA403CUL/L, SA402RCUL/L, SA403RCUL/L 4.626 (117.5) Insulation barrier R0 .0 78 8.858 (225) 10.118 (257) 8.425-8.504 (214-216) 3.307 (84) Trip button 2.087 (53) #1/4-20 Tap or 0.276 dia hole (M6 or Ø7) Breaker Breaker (R 2) or le ss 3.622 (92) or more 0.965 (24.5) 3.543 (90) 0.315 dia (Ø8) 0.531 dia (Ø13.5) Mounting hole 2.0 (51) 4.016 (102) 2.047 (52) 4.134 (105) 0.591 (15) 1.161 (29.5) 5.394 (137) or more 0.591 (15) 2.047 (52) 1.732 (44) 1.732 (44) 1.732 (44) 5.512 (140) 0.315 (8) 1.417 (36) Panel drilling 4.055 (103) 0.177 (4.5) Front panel cutting Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. 4.213 (107) 5.748 (146) ● SA603RCUL/L1, SA803RCUL/L1 0.571 dia (Ø14.5) #1/4-20 Tap or 0.276 dia hole (M6 or Ø7) Breaker 1.85 (47) ON R0 .0 78 Breaker (R 2) or le ss 3.622 (92) or more 10.83 (275) 9.567 (243) 1.634 (41.5) 0.394 (10) 9.567 (243) 1.85 (47) ON 0.275 dia (Ø7) 0.571 dia (Ø14.5) 4.134 (105) 3.425 (87) 0.965 (24.5) 3.543 (90) Mounting hole 4.016 (102) 2.008 (51) (SA803RCUL/L1) 1.516 (38.5) 0.275 (7) 0.275 dia (Ø7) (SA603RCUL/L1) Insulation barrier 2.087 (53) 8.071 (205) Trip button 0.315 (8) 1.256 (32) 1.732 (44) 0.59 (15) M12x40 2.756 (70) 8.15 (207) or more Panel drilling Front panel cutting 0.275 (7) 1.634 (41.5) 0.394 (10) 1.752 (44.5) 3.72 (94.5) Note: 2-pole breakers are supplied in 3-pole frames with current carrying parts omitted from center pole. 2.756 (70) 2.756 (70) 3.72 (94.5) 8.268 (210) 4.055 (103) 4.055 (103) 4.213 (107) 0.177 (4.5) 0.177 (4.5) 5.748 (146) 4.213 (107) 5.748 (146) ● SA603RCUL/L 2.5 (63.5) 2.5 (63.5) 2.756 (70) 2.756 (70) 8.268 (210) 9.055 (230) 15 Trip button 1.929 (49) 5.157 (131) 1.732 (44) Breaker (R 2) or le ss 3.622 (92) or more 2.087 (53) 8.071 (205) R0 .0 78 9.567 (243) 0.275 dia (Ø7) 5.157 (131) 4.016 (102) ON 3.543 (90) #1/4-20 Tap or 0.276 dia hole (M6 or Ø7) Breaker Mounting hole 0.965 (24.5) 9.567 (243) 7.342 (186.5) 1.555 (39.5) 0.315 (8) 1.85 (47) 7.968 (202.4) 2.008 (51) 10.83 (275) 0.571 dia (Ø14.5) Insulation barrier 2.145 (54.5) Terminal cover 0.315 (8) 1.673 (42.5) 3.72 (94.5) 0.118 (3) 4.055 (103) 4.213 (107) 0.177 (4.5) 4.429 (112.5) 5.75 (146) 2.756 (70) 8.15 (207) or more Panel drilling Front panel cutting Dimensions unit: inch (mm) ● SA803RCUL/700L 3.543 (90) 4.016 (102) R0 .0 78 9.567 (243) ON 0.275 dia (Ø7) Mounting hole 0.965 (24.5) 9.567 (243) 7.342 (186.5) #1/4-20 Tap or 0.276 dia hole (M6 or Ø7) Breaker 1.85 (47) 7.968 (202.4) 2.008 (51) 10.83 (275) 1.634 (41.5) 0.394 (10) 2.087 (53) 8.071 (205) Trip button 1.929 (49) 5.157 (131) 0.906 (23) 1.732 (44) Breaker (R 2) or le ss 3.622 (92) or more 0.571 dia (Ø14.5) Insulation barrier 2.539 (64.5) 5.157 (131) Terminal cover 0.394 (10) 1.752 (44.5) 2.756 (70) 8.15 (207) or more Panel drilling Front panel cutting 3.72 (94.5) 2.5 (63.5) 2.5 (63.5) 2.756 (70) 2.756 (70) 0.118 (3) 4.055 (103) 4.213 (107) 0.177 (4.5) 4.429 (112.5) 5.75 (146) 8.268 (210) 9.055 (230) ● SA803RCUL/800L Insulation barrier Terminal cover 0.571 dia (Ø14.5) Breaker Breaker (R 2) or le ss 3.622 (92) or more 2.087 (53) 8.071 (205) R0 .0 78 9.567 (243) 0.275 dia (Ø7) 5.157 (131) 3.091 (78.5) 3.543 (90) #1/4-20 Tap or 0.276 dia hole (M6 or Ø7) ON 4.016 (102) 0.965 (24.5) 9.576 (243) 0.394 (10) 1.85 (47) Mounting hole 2.008 (51) Trip button 5.157 (131) 10.83 (275) 4.134 (105) 1.634 (41.5) 2.756 (70) 8.15 (207) or more Panel drilling Front panel cutting 0.394 (10) 1.752 (44.5) 3.72 (94.5) 1.732 (44) 1.929 (49) 2.756 (70) 2.756 (70) 4.429 (112.5) 8.268 (210) 5.748 (146) 9.055 (230) 16 Dimensions of terminal blocks for internal accessories: inch (mm) Dimensions of Undervoltage/Shunt trip device H 3.7 (94) 50 to 225A Frame W 0.5 (12.5) Breakers WxH SA52RCUL, EA102CUL 1.0 (25) x 3.94 (100) SA53RCUL, EA103CUL SG53RCUL, EG102CUL, EG103CUL 1.0 (25) x 3.94 (100) SA102CUL, SA103CUL, SG103CUL SA102RCUL, SA103RCUL 1.0 (25) x 5.04 (128) SA202CUL, SA203CUL, SG203CUL SA202RCUL, SA203RCUL 1.0 (25) x 5.04 (128) 0.5 (12.5) 400 to 800A Frame 1-terminal block 0.75 (19) 4.7 (117.5) K K F or W W R 1.5 (38) 2-terminal block Dimensions of terminal covers: inch (mm) C B A Breaker For Screw Terminals Type For Lug Terminals A B C BZ6TS10C2U (Short) 1.969 (50) 0.386 (9.8) 2.106 (53.5) BZ6TB10C2U (Long) 1.969 (50) 1.575 (40) 2.106 (53.5) BZ6TS10C3U (Short) 2.953 (75) 0.386 (9.8) 2.106 (53.5) BZ6TB10C3U (Long) 2.953 (75) 1.575 (40) 2.106 (53.5) BZ-TS30B-3 3.55 (90) 0.4 (10) BZ-TS40B 4.13 (105) 0.4 (10) – – – – – – – – 17 Type For Flat Terminals A B C – – – – – – – – 2.3 BZ-TB30B-3 (58.5) 3.55 (90) 1.58 (40) 2.3 BZ-TB40B (58.5) 4.13 (105) BZ-TB60B comes with breaker Type Applicable Breakers A B C – – – – SA52RCUL, EA102CUL – – – – SA53RCUL, EA103CUL SG53RCUL, EG102CUL, EG103CUL 2.3 BZ-TL30B-3 (58.5) 3.54 (90) 2.36 (60) 2.3 (58.5) SA102CUL, SA103CUL, SG103CUL SA102RCUL, SA103RCUL 1.97 (50) 2.3 BZ-TL40B (58.5) 4.13 (105) 2.95 (75) 2.3 (58.5) SA202CUL, SA203CUL, SG203CUL SA202RCUL, SA203RCUL 7.48 (190) 4.57 (116) 3.84 BZ-TB60B (97.5) 7.48 (190) 4.57 (116) 3.84 (97.5) SA402CUL, SA403CUL SA402RCUL, SA403RCUL 9.06 (230) 5.157 (131) 3.84 BZ-TB70B (97.5) 9.06 (230) 5.32 (135) 3.84 (97.5) SA603RCUL SA803RCUL Internal Accessories ● Auxiliary Switches and Alarm Switches Part number SA52RCUL, SA53RCUL, SG52RCUL, SG53RCUL EA102CUL, EA103CUL EG103CUL Left side Right side BZ6WL10CU*1 BZ6WR10CU BZ6WDL10CU*1 BZ6WDR10CU BZ6KR10CU BZ6KL10CU*1 BZ6KDL10CU*1 BZ6KDR10CU BZ6WKL10CU*1 BZ6WKR10CU BZ6WDKDR10CU BZ6WDKDL10CU*1 Lead wire type Aux Alarm Aux, Alarm W WD K KD WK WDKD *1; For 3 pole type only. Aux Alarm Aux, Alarm W WD K KD WK WDKD *1; For 3 pole type only. Rating Standard: W, K Breaker type Operating voltage 120V AC 240V AC 125V DC 250V DC *2; For MCCB's only SA52RCUL, SA53RCUL, SG52RCUL, SG53RCUL EA102CUL, EA103CUL EG103CUL Left side Right side BZ6WL10CAU*1 BZ6WR10CAU 1 BZ6WDL10CAU* BZ6WDR10CAU BZ6KL10CAU*1 BZ6KR10CAU 1 BZ6KDL10CAU* BZ6KDR10CAU 1 BZ6WKL10CAU* BZ6WKR10CAU 1 BZ6WDKDR10CAU BZ6WDKDL10CAU* With terminal block type SA102CUL, SA103CUL SA102RCUL, SA103RCUL SG103CUL Left side Right side BZ6WL30CU BZ6WR30CU*2 BZ6WDL30CU BZ6WDR30CU*2 BZ6KL30CU BZ6KR30CU*2 BZ6KDL30CU BZ6KDR30CU*2 BZ6WKL30CU BZ6WKR30CU*2 BZ6WDKDL30CU BZ6WDKDR30CU*2 *2; For MCCB's only SA102CUL, SA103CUL SA102RCUL, SA103RCUL SG102CUL, SG103CUL Left side Right side BZ6WL30CAU BZ6WR30CAU*2 BZ6WDL30CAU BZ6WDR30CAU*2 BZ6KL30CAU BZ6KR30CAU*2 BZ6KDL30CAU BZ6KDR30CAU*2 BZ6WKL30CAU BZ6WKR30CAU*2 BZ6WDKDL30CAU BZ6WDKDR30CAU*2 *2; For MCCB's only SA52RCUL, SA53RCUL, EA102CUL, EA103CUL SG53RCUL, EG102CUL, EG103CUL Rated current (A) 3.6 1.8 0.55 0.27 SA202CUL, SA203CUL SA202RCUL, SA203RCUL SG203CUL Left side Right side BZ6WL40CU BZ6WR40CU*2 BZ6WDL40CU BZ6WDR40CU*2 BZ6KL40CU BZ6KR40CU*2 BZ6KDL40CU BZ6KDR40CU*2 BZ6WKL40CU BZ6WKR40CU*2 BZ6WDKDL40CU BZ6WDKDR40CU*2 SA202CUL, SA203CUL SA202RCUL, SA203RCUL Left side BZ6WL40CAU BZ6WDL40CAU BZ6KL40CAU BZ6KDL40CAU BZ6WKL40CAU BZ6WDKDL40CAU Right side BZ6WR40CAU*2 BZ6WDR40CAU*2 BZ6KR40CAU*2 BZ6KDR40CAU*2 BZ6WKR40CAU*2 BZ6WDKDR40CAU*2 *2; For MCCB's only SA102CUL, SA103CUL, SA102RCUL, SA103RCUL SA202CUL, SA203CUL, SA202RCUL, SA203RCUL SG103CUL, SG203CUL Rated current (A) 5 3 0.2 * 0.2 * SA402CUL, SA403CUL, SA402RCUL, SA403RCUL Minimum load SA603RCUL, SA803RCUL SG403CUL Rated current (A) 5 W, K: 5V DC 160mA 5 30V DC 30mA 0.2 * 0.2 * SA102CUL, SA103CUL, SA102RCUL, SA103RCUL SA202CUL, SA203CUL, SA202RCUL, SA203RCUL SG103CUL, SG203CUL Rated current (A) 0.1 SA402CUL, SA403CUL, SA402RCUL, SA403RCUL Minimum load SA603RCUL, SA803RCUL Note: * Manufacturer's self certification For low current: WD, KD Breaker type Operating voltage 30V DC SA52RCUL, SA53RCUL, EA102CUL, EA103CUL SG53RCUL, EG102CUL, EG103CUL Rated current (A) 0.1 Rated current (A) 0.1 WD, KD: 5V DC 1mA 30V DC 1mA Operation Type of switch Condition of MCCB ON Auxiliary switch OFF 11/AXcL TRIP 11/AXcL 14/AXaL 14/AXaL (W) 12/AXbL Alarm switch 91/ALcL 12/AXbL 94/ALaL 91/ALcL 94/ALaL (K) 92/ALbL 92/ALbL ● Shunt trip devices For MCCB Breaker part number SA52RCUL, SA53RCUL EA102CUL, EA103CUL Operating voltage Part number Spec With terminal block type Input (VA) Internal Circuit 150 Continuous BZ6FA10CAU with burnout 150 prevention BZ6FK10CAU contact 200 BZ6FP10CAU 100 to 120VAC 100 to 110VDC 200 to 240VAC FA Lead wire type BZ6FA10CU FK BZ6FK10CU 380 to 450VAC FP BZ6FP10CU FR BZ6FR30CU BZ6FR30CAU FS BZ6FS30CU BZ6FS30CAU 100-125VAC 100-110VDC 200-240VAC 200-220VDC 24VAC/DC FT BZ6FT30CU BZ6FT30CAU FU BZ6FU30CU BZ6FU30CAU FR BZ6FR40CU BZ6FR40CAU 48VAC/DC FS BZ6FS40CU BZ6FS40CAU 100-125VAC 100-110VDC 200-240VAC 200-220VDC FT BZ6FT40CU BZ6FT40CAU FU BZ6FU40CU BZ6FU40CAU SA102CUL, SA103CUL 24VAC/DC SA102RCUL, SA103RCUL 48VAC/DC SA202CUL, SA203CUL SA202RCUL, SA203RCUL Code 30(AC) 35(DC) 30(AC) 35(DC) 30(AC) 35(DC) 30(AC) 35(DC) 30(AC) 35(DC) 30(AC) 35(DC) 30(AC) 35(DC) 30(AC) 35(DC) Continuous Time rating (ms) 7-13 Terminal No. and Internal circuit Continuous with burnout Prevention contact S1 7-16 Continuous S1 Continuous S2 S2 13-21 18 Internal Accessories ● Shunt trip devices For MCCB Breaker part number Operating voltage Code Lead wire type SA402CUL, SA403CUL 24-48VAC SA402RCUL, SA403RCUL 24-48VDC 100-240VAC 100-220VDC SA603RCUL 24-48VAC SA803RCUL 24-48VDC 100-240VAC 100-220VDC FV FW 3 FV 2 FW 3 SG53RCUL EG102CUL, EG103CUL SG103CUL SG203CUL SG403CUL Time rating (ms) 7-21 Terminal No. and Internal circuit Continuous S1 Continuous S2 7-21 ; Factory installed accessories For ELCB Breaker part number Part number Spec With terminal block type Input (VA) Internal Circuit 2 Continuous Operating voltage 100VAC 50Hz 100 to 110VAC 60Hz 200VAC 50Hz 200 to 220VAC 60Hz 400VAC 50Hz 400 to 440VAC 60Hz 100VAC 50Hz 100 to 110VAC 60Hz 200VAC 50Hz 200 to 220VAC 60Hz 400VAC 50Hz 400 to 440VAC 60Hz 100VAC 50Hz 100 to 110VAC 60Hz 200VAC 50Hz 200 to 220VAC 60Hz 400VAC 50Hz 400 to 440VAC 60Hz 24-48VAC 24-48VDC 100-240VAC 100-220VDC Code F2 Lead wire type – Part number Spec With terminal block type Input (VA) Internal Circuit Continuous 16 BZ6F210CAU F7 – BZ6F710CAU 16 F8 – BZ6F810CAU 22 F2 – BZ6F230CAU 200 F7 – BZ6F730CAU 150 F8 – BZ6F830CAU 200 F2 – BZ6F240CAU 200 F7 – BZ6F740CAU 150 F8 – BZ6F840CAU 200 FV 2 FW 3 Time rating (ms) 7-13 Terminal No. and Internal circuit Continuous S1 Continuous 7-13 Continuous 7-13 Continuous 7-21 S2 ; Factory installed accessories ● Undervoltage trip devices Breaker part number SA52RCUL, SA53RCUL EA102CUL, EA103CUL SG53RCUL EG102CUL, EG103CUL SA102CUL, SA103CUL SA102RCUL, SA103RCUL SG103CUL SA202CUL, SA203CUL SA202RCUL, SA203RCUL SG203CUL SA402CUL, SA403CUL SA402RCUL, SA403RCUL Operating voltage Code 100VAC 50Hz 100 to 110VAC 60Hz 200VAC 50Hz 200 to 220VAC 60Hz 400VAC 50Hz 400 to 440VAC 60Hz 100-110VDC R2 Lead wire type – Part number Spec With terminal block type Input (VA) Internal Circuit Time rating (ms) 3 70% to 20% of 85% or more of BZ6R210CAU rated voltage rated voltage 3 BZ6RW10CAU RW – R9 – RT – 200 100VAC 50Hz 100 to 110VAC 60Hz 200VAC 50Hz 200 to 220VAC 60Hz 400VAC 50Hz 400 to 440VAC 60Hz 100-110VDC R2 – 200 RW – 150 R9 – 200 RT – 200 100VAC 50Hz 100 to 110VAC 60Hz 200VAC 50Hz 200 to 220VAC 60Hz 400VAC 50Hz 400 to 440VAC 60Hz 24VAC/DC R2 – 200 RW – 150 R9 – 200 RR 2 48VAC/DC RS 2 100-110VAC/DC RX 3 200-240VAC 200-220VDC 24VAC/DC RU 3 RR 2 48VAC/DC RS 2 100-110VAC/DC RX 3 200-240VAC 200-220VDC RU 3 BZ6R910CAU 4 SG403CUL SA603RCUL SA803RCUL ; Factory installed accessories 19 Terminal No. and Internal circuit P1 P2 Internal Accessory Combinations for MCCB 3P 2P Right Left Handle Handle Auxiliary switch: W Shunt trip: F Alarm switch: K Undervoltage trip: R Right MCCB S series SA52RCUL * SA53RCUL * SA102CUL SA103CUL SA102RCUL SA103RCUL SA202CUL SA203CUL SA202RCUL SA203RCUL E series EA102CUL * EA103CUL * – – 2 3 2, 3 2, 3 Pole SA402CUL SA403CUL SA402RCUL SA403RCUL SA603RCUL SA803RCUL Auxiliary switch SPDT W Alarm switch SPDT K Shunt trip F Undervoltage trip R W2 N/A W+K W2+K K2 W+K2 W2+K2 W+F W2+F N/A N/A N/A N/A N/A N/A N/A N/A W+R W2+R K+F N/A N/A N/A K+R W+K+F N/A W+K+R K2+F K2+R W2+K+F W2+K+R W+K2+F W+K2+R W2+K2+F W2+K2+R N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Notes: • The lead wires are pulled out and terminal blocks are attached on the same side of the accessory attached. * Terminal block connection is standard method 20 Internal Accessory Combinations for ELCB 3P 2P Right Left Handle Handle ELCB Auxiliary switch: W Shunt trip: F (External mounting method) Alarm switch: K Undervoltage trip: R Right SG series SG53RCUL * SG103CUL SG203CUL SG403CUL EG series EG102CUL * EG103CUL * – – 3 3 Pole 2, 3 Auxiliary switch SPDT W Alarm switch SPDT K Shunt trip F Undervoltage trip R W2 N/A W+K W2+K K2 W+K2 W2+K2 N/A N/A N/A N/A W+F W+R W2+R N/A K+F K+R K2+R N/A W+K+F W+K+R W2+K+R W+K2+R W2+K2+R N/A N/A N/A Notes: • The lead wires are pulled out and terminal blocks are attached on the same side of the accessory attached. * Terminal block connection is standard method 21 External Accessories ● Operating Handles Applicable Breakers Part number V type (Door mount) N type (Breaker mount) BZ6V10C BZ6N10CP SA52RCUL, SA53RCUL, EA102CUL, EA103CUL, SG53RCUL, EG102CUL, EG103CUL BZ6V30C BZ6N30CP SA102CUL, SA103CUL, SA102RCUL, SA103RCUL, SG103CUL BZ6V40C BZ6N40CP SA202CUL, SA203CUL, SA202RCUL, SA203RCUL, SG203CUL BZ6V60C BZ6N60CP SA402CUL, SA403CUL, SA402RCUL, SA403RCUL, SG403CUL BZ6V70C BZ6N70CP SA603RCUL, SA803RCUL ● Terminal Covers For Screw Terminals For Lug Terminals *1 BZ6TS10C2U (Short) *2 2 BZ6TB10C2C (Long) *2 2 BZ6TS10C3C (Short) *2 2 BZ6TB10C3U (Long) *2 2 BZ-TS30B-3 (Short) 2 BZ-TB30B-3 (Long) 2 BZ-TS40B (Short) 2 BZ-TB40B (Long) 2 _ _ _ _ Applicable Breakers For Flat Terminals *1 Packing quantity Packing quantity Type Type Packing quantity Type _ _ _ _ SA52RCUL, EA102CUL _ _ _ _ SA53RCUL, EA103CUL, SG53RCUL, EG102CUL, EG103CUL BZ-TB30B-3 SA102CUL, SA103CUL, SG103CUL *1 BZ-TL30B-3 2 BZ-TB40B 2 2 BZ-TB60B 2 SA202RCUL, SA203RCUL SA402RCUL, SA403RCUL , SG403CUL BZ-TB60B 2 comes with a breaker SA102RCUL, SA103RCUL SA202CUL, SA203CUL, SG203CUL *1 BZ-TL40B 2 SA402RCUL, SA403RCUL SA603RUL BZ-TB70B 2 SA803RUL Note: *1 Lug Terminals and Flat Terminals are not available for SG103CUL and SG203CUL. *2 Terminal covers are supplied with breaker as standard. If long terminal cover is required, please specify TB in the part number. ● Insulation Barriers Insulation barriers Type Applicable Breakers Packing quantity BZ6B10C 4 SA52RCUL, SA53RCUL, EA102CUL, EA103CUL, SG53RUCL, EG102CUL, EG103CUL *2 BZ6B30CU 4 SA102CUL, SA103CUL, SG103CUL, SA102RCUL, SA103RUCL *1 BZ6B40CU 4 SA202CUL, SA203CUL, SG203CUL, SA202RCUL, SA203RUCL *1 B-43 4 SA402CUL, SA403CUL, SG403CUL, SA402RCUL, SA403RCUL, SA603CUL, SA803CUL *1 Note: *1 Insulation Barriers for line side and load side are provided with the Breaker (2-pole Breaker; 2 pcs, 3-pole Brealer; 4 pcs) as standard. *2 Insulation Barriers are required only for flat terminal type. ● Terminal Kits (Field Installable) Lug Terminal Kit Flat Terminal Kits Type Packing quantity Type Applicable Breakers Packing quantity BU-SU20B 3 — — SA52RCUL, SA53RCUL, SG53RUCL BU-SU25B 3 — — EA102CUL, EA103CUL,EG102CUL, EG103CUL BZ6SU35B 3 BZ6TA100 3 SA102CUL, SA103CUL, SA102RCUL, SA103RUCL BZ6SU50B 3 BZ6TA225 3 SA202CUL, SA203CUL, SA202RCUL, SA203RUCL BZ-SU60B 3 BZ6TA350 3 SA402CUL, SA403CUL, SA402RCUL, SA403RCUL (250-300A) BZ6TA400 3 SA402CUL, SA403CUL, SA402RCUL, SA403RCUL (400A) BU-SU70B-600 3 BZ-TA600 3 SA603CUL BU-SU70B-800 3 BZ-TA700 3 SA803CUL (700A) BZ-TA800 3 SA803CUL (800A) ● Handle Locking Covers for Lockout Part number Applicable Breakers BZ6L10C SA52RCUL, SA53RCUL, EA102CUL, EA103CUL, SG53RCUL, EG102CUL, EG103CUL BZ6L30C SA102CUL, SA103CUL, SA102RCUL, SA103RCUL, SG103CUL BZ6L40C SA202CUL, SA203CUL, SA202RCUL, SA203RCUL, SG203CUL BZ-L70B SA402CUL, SA403CUL, SA402RCUL, SA403RCUL, SA603RCUL, SA803RCUL 22 Operating Handles Dimensions Unit: inch (mm) 50A~225A Frame V Type Handle 4.14 (105) Handle C/L 4.14 (105) Door panel 4–0.6 dia (Ø15) MCCB, ELCB Handle C/L Lock plate max 1.909 (48.5) 2.402 (61) 2.52 (64) ) 90 (Ø 3.07 (78) Panel Drilling Handle type Applicable Dimensions (mm) H Breakers BZ6V10C Optional shaft (BZ-VS1) BZ6V30C 1.57 (40) 0.78 (20) ia 5d 3.5 Panel thickness 0.05~0.125 (1.2~3.2) H 0.98 (25) 0.39 (10) Load Breaker C/L 2.17 (55) The distance between the handle and breaker can be shortened by cutting the optional shaft (X = H - 3.78 (96)) 4.73 (120) Install the door hinge in the shaded area. 3.07 (78) Line BZ6V40C SA52/53RCUL SG53RCUL EA102/103CUL EG102/103CUL SA102CUL SA103CUL SA102RCUL SA103RCUL SG103CUL SA202CUL SA203CUL SA202RCUL SA203RCUL SG203CUL Standard 4.13±0.078 (105±2) with the optional shaft 4.13±0.078 (105±2) 5.6 to 9.84 (142 to 250) 4.13±0.078 (105±2) 5.6 to 9.84 (142 to 250) 5.6 to 9.84 (142 to 250) Note: Handle protection structure IP54 (IEC529, JIS C0920) 400A~800A Frame V Type Handle 5.91 (150) Line Decorative plate 5.91 (150) 1.18 (30) 5.91 (150) Lock plate 3.94 (100) Mounting screw 7.87 (200) Panel thickness 0.063 ~ 0.125 (1.6~3.2) H 4.41 (112) 4.41 (112) Load 2.48 (63) 4–0.4 dia (Ø10) 38) (Ø1 dia 4 5.4 Optional shaft (BZ-VS2) Install the door hinge in the shaded area. Handle type Applicable Dimensions (mm) Breakers Breaker C/L BZ6V60C H Standard with the optional shaft SA402CUL 7.48±0.078 7.96 to 9.84 SA403CUL (190±2) (202 to 250) 7.48±0.078 7.96 to 9.84 (190±2) (202 to 250) SA402RCUL SA403RCUL Handle C/L Panel Drilling 23 The distance between the handle and breaker can be shortened by cutting the optional shaft (X = H - 6.36 (161.5)) BZ6V70C SA603RUL, SA803RUL Note: Handle protection structure IP54 (IEC529, JIS C0920) 2.16 (55) 0.39 (10) Door panel Operating Handles Dimensions Unit: inch (mm) S E Panel thickness 0.05~0.126 (1.2~3.2) Max 2.71 (69) Load 90) ia (Ø 4d 3.5 2.17 (55) 0.83 (21) EA FAB.ELB Handle C/L 7.87 (200) 5.28 (134) 1.91 (48.5) 0.2 (5) Max 2.24 (57) OFF T E S E R E N / EL FAB.ELB Handle C/L 0.28 (7) IP R T 7.87 (200) 6.81 (173) 5.0 (127) 0.95 (24) ON 3.07 (78) Max 2.32 (159) Line 4.14 (105) ) 15 (Ø a di 16 0. Handle C/L 4- 1.89 (48) Panel 1.1 (28) 4.13 (105) 2.52 (64) 2.24 (57) 0.79 (20) 1.1 (28) 50A~100A Frame N Type Handle 3.07 (78) 4.06 (103) 2.8 (71) Panel Drilling Install the door hinge in the shaded area. Handle type BZ6N10CP Applicable Breakers SA52RCUL EA102CUL SA53RCUL EA103CUL SG53RCUL EG102CUL EG103CUL Mounting screw #8-32X31/2 (M4X85) Note: When using a Dust-proof packing, handle protection structure is IP 50 (IEC 529, JIS C0920) 100A~225A Frame N Type Handle 4.49 (114) 4.13 (105) Max 2.72 (69) 2.17 (55) 1.89 (48) 4.06±0.078 (103±2) 2.36 (60) ) 15 (Ø a di 6 1 Handle 0. C/L 4- Line Panel 7.87 (200) 6.81 (173) 5.0 (127) 7.87 (200) 5.28 (134) 1.91 (48.5) A S E 0.83 (21) E N / E E L 0.2 (5) 0.28 (7) R E S E 1.1 (28) 90) ia (Ø 4d 3.5 3.07 (78) FAB.ELB Handle C/L T OFF 4.14 (105) FAB.ELB Handle C/L 0.95 (24) ON IP R T 0.79 (20) 1.1 (28) 0.28 (7) 2.8 (71) 3.07 (78) Load Install the door hinge in the shaded area. Panel Drilling Panel thickness 0.05~0.126 (1.2~3.2) Handle type BZ6N30CP Applicable Breakers SA102CUL SG103CUL SA103CUL SA102RCUL SA103RCUL SA202CUL SG203CUL SA203CUL SA202RCUL SA203RCUL BZ6N40CP Mounting screw #8-32X31/2 (M4X85) #8-32X31/2 (M4X85) Note: When using a Dust-proof packing, handle protection structure is IP 50 (IEC 529, JIS C0920) 400A ~ 800A Frame N Type Handle 5.91 (150) ) 38 Ø1 2.56 (65) 1.38 (35) 0.98 (25) 0.59 (15) 1.38 (35) 0.3 (7.5) 0.98 (25) 3.94 (100) 2.56 (65) ( ia 3d 5.4 4.41 (112) FAB.ELB Handle C/L 5.91 (150) RE 5.91 (150) LE ASE O F F T SE RE / N E P O Load FAB.ELB Handle C/L Lock plate 3.94 (100) Handle C/L 3.78 (96) P 3.78 (96) I T 0.67 (17) O N R 4.41 (112) Panel Line 7.87 (200) 7.87 (200) AUX. Handle (Only BZ6N70CP) Panel thickness 0.063~0.126 (1.6~3.2) 2.09 (53) Panel Drilling Install the door hinge in the shaded area. 6.18 (157) Handle type Applicable Breakers Mounting screw BZ6N60CP SA402CUL 1/4-20X41/2 SA403CUL (M6X110) SA402RCUL SA403RCUL BZ6N70CP SA603RCUL, SA803RCUL Note: When using a Dust-proof packing, handle protection structure is IP 50 (IEC 529, JIS C0920) 24 Wiring Connecting Precautions • When connecting the wires, follow the instruction of NEC (National Electric Code, USA) or CEC (Canadian Electrical code Part 1, Canada). • For connecting, use copper wire rated for 75°C. It is recommended to use UL or CSA approved wires. • Keep the connection of the wire sufficiently tight, because a very large electromagnetic force will be generated, when the short circuit current is applied. • Perform additional tightening of the terminal screws periodically. Allowable wire spec for Lug Terminals Terminal Construction Screw Terminals 50A, EA/EG 100A Frame SA100~225A Frame SG100~225A Frame Flat Terminals 400~800A Frame : Available Number of strands connecting wires Lug Terminals Wire size AWG or MCM (mm2) Number of strands 14 – 2 (2.1 – 33.6) 7 1 – 4/ 0 (42.4 – 107.2) 19 250 – 500 (127 – 250) 37 (mm2) Values are those converted from AWG or MCM size : Not available Caution • Two wires can not be connected to the lug terminal at once. • Follow the number of strands of wire indicated in the table. • Multiconductor wire can not be connected. • Do not solder the end of the wire. Max Wire Sizes and Tightening Torque Tightening torque Type SA53RCUL SG53RCUL EA102CUL, EA103CUL EG102CUL, EG103CUL SA102CUL SA102RCUL SA103CUL SA103RCUL SG103CUL SA202CUL SA202RCUL SA203CUL SA203RCUL SG203CUL SA402CUL SA402RCUL SA403CUL SA403RCUL SG403CUL SA603RCUL SA803RCUL Rated Wire size Current (A) AWG or MCM (mm2) 3 5 10 15 20 30 40 50 60 75 100 15 20 30 32 40 50 60 70 75 80 90 100 125 150 175 200 225 250 300 350 400 500 600 700 800 14 AWG (2.1mm2) 14 AWG (2.1mm2) 14 AWG (2.1mm2) 14 AWG (2.1mm2) 12 AWG (3.3mm2) 10 AWG (5.3mm2) 8 AWG (8.4mm2) 6 AWG (13.3mm2) 6 AWG (13.3mm2) 4 AWG (21.1mm2) 3 AWG (26.7mm2) 14 AWG (2.1mm2) 12 AWG (3.3mm2) 10 AWG (5.3mm2) 8 AWG (8.4mm2) 8 AWG (8.4mm2) 8 AWG (8.4mm2) 6 AWG (13.3mm2) 4 AWG (21.1mm2) 4 AWG (21.1mm2) 4 AWG (21.1mm2) 3 AWG (26.7mm2) 3 AWG (26.7mm2) 1 AWG (42.4mm2) 1/0 AWG (53.5mm2) 2/0 AWG (67.4mm2) 3/0 AWG (85.0mm2) 4/0 AWG (107.2mm2) 250 MCM (127mm2) 350 MCM (177mm2) 500 MCM (253mm2) 3/0 AWG x 2 (85.0mm2 x 2) 250 MCM x 2 (126.7mm2 x 2) 350 MCM x 2 (177.4mm2 x 2) 500 MCM x 2 (253.4mm2 x 2) 300 MCM x 3 (152mm2 x 3) Applicable ring (crimp) terminal Screw / Flat terminal Lug terminal JST (UL file No.E42024) Screw / Flat terminal Screw; 20-25 lb.-In (2.3-2.8N-m) 50 lb. - In. (5.8N-m) R2-5 R2-5 R5.5-5 R5.5-5 R8-5 R8-5 R14-8 22-S8 38-S8 R2-8 R5.5-8, 5.5-S8 R5.5-8, 5.5-S8 R8-8, 8-8NS R2-8 R3.5-8, R5.5-8 R5.5-8 R8-8 R14-8 22-S8 38-S8 2-8 5.5-8 R14-8, 14-8NS, 14-S8 R22-8, 22-S8, CB22-S8 Flat; 30-40 lb.-in. (3.5-4.5N-m) 50 lb. - In. (5.8N-m) 50 lb. - In. (5.8N-m) 93 lb. - In. (10.5N-m) 200 lb. - In. (23N-m) 375 lb. - In. (43.5N-m) 375 lb. - In. (43.5N-m) 416 lb. - In. (47N-m) 275 lb. - In. (31.9N-m) AIKOKU (UL file No.E74103) DST (UL file No.E74917) 8-8 2-8, 2-B8 3.5-8, 5.5-8 5.5-8 8-8 R14-8, R14-8S R22-8, R22-8S, CB22-8S 14-8 22-8 14-S8, 14-8 22-S8, 22-8, CB22-8 38-S8 R38-8S, CB22-8S 38-8S 38-S8 R38-8, 38-S8 R60-8, 60S8 70-8 CB80-S8 CB100-S8 150-12 180-12 325-12 R80-12 150-12 180-12 325-12 - R38-8S, R38-8 R60-8, CB60-8, CB60-8S R70-8 R150-12 R180-12 R325-12S R80-12 R150-12 R180-12 R325-12S - 38-8S 60-8 - 38-S8 60-8, CB60-8 70-8 CB80-8 CB100-8 - Notes: *1 Ring (Crimp) Terminal Manufacturer : JST=Japan Solderless Terminal MFG Co., Ltd. DST=Daido Solderless Terminal MFG Co., Ltd. AIKOKU=Aikoku Kogyou KK. NICHIFU=Nichifu Terminal Co., Ltd. *2 167°F (75°C) Copper wire 25 NICHIFU (UL file No.E44245) Flange Disconnect Handle <UF Type Handle> Features • Flexible cable operation. • Covering up to 400-amp frame size • Easy installation on circuit breakers • Complies with IP 54, NEMA type 12 protection degree. • Accepts ANSI standard American padlock devices. • Off lockable: 10 padlock device, Max 3 pieces. • UL listed product. [UL489, File No. E93289] Specifications Breaker frame size 100 amp frame 225 amp frame 400 amp frame Part numbers BZ6UF30D BZ6UF40D BZ6UF60D SA103BAUL, SA203BAUL, SA403BUL, SA103RAUL, SA203RAUL, SA403RUL, SA103CUL, SA203CUL, SA403CUL SA103RCUL, SA203RCUL, SG203BAUL, SG203BAUL, SG103CUL SG203BAUL, Applicable products MCCB’s ELCB’s SG403CUL - Operating handle facing up, Breaker is in ON position Operating instructions - Operating handle facing down, Breaker is in OFF position or is reset. - Panel door cannot be opened when in ON, OFF or Trip position. In order to open the door, the handle must be turned toward reset position. - Release screw is standard. If you want to open a panel door in ON position, please turn on the release screw using flat head screwdriver. Mechanical endurance (cycles) 10,000 Ambient temperature - 10 to 40˚C Relative humidity 95% RH Atmosphere Accessories 8,000 6,000 No excessive dust, smoke, corrosive gases, flammable gases, steam or salt. Terminal cover BZ6UTB30 BZ6UTB40 BZ6UTB60 Cable 1.5m BZ6UW30-15A BZ6UW40-15A BZ6UW60-15A Cable 2.0m BZ6UW30-20A BZ6UW40-20A BZ6UW60-20A BZ6UW30-30A BZ6UW40-30A BZ6UW60-30A Cable 3.0m 26 Flange Disconnect Handle <UF Type Handle> Ordering information Specify the following: 1. Handle with operation part numbers 2. Cable part numbers 3. Terminal cover part number if required. Main unit (Drive unit and handle unit) BZ6UF 30 D Product category Index Frame size Code Used for 30 100 amp frame breakers 40 225 amp frame breakers 60 400 amp frame breakers Cable BZ6UW 30 - 15 A Index Product category Cable length Frame size Code Specifications 15 1.5m Code Used for 20 2.0m 30 100 amp frame breakers 30 3.0m 40 225 amp frame breakers 60 400 amp frame breakers Terminal cover BZ6UTB 30 Frame size Product category Code Used for 30 100 amp frame breakers 40 225 amp frame breakers 60 400 amp frame breakers Dimensions of handle operating parts (common): inch (mm) ● Handle Operating parts (Common) 3.15 (80) ON 1.06 (27) 2.24 (57) Panel 2.24 (57) 1.14 (29) 132 0.49 (12.5) 1.08 (27.5) 2.95 (75) 150˚ 5.71 (145) ) .5 (Ø5 2.72 max (69) .22 2-0 2.36 (60) Release tab OFF (RESET) 5.87 (149) Lock lever ON 10.83 (275) Panel 7) (Ø 0.87 (22) H (Note 3) 26 0. 2- Off lock hole Release screw 1.10 (28) or more RESET (Note 1) The flange handle consists of handle operating parts and actuators parts. (Note 2) Operating parts can be installed on either right-or-left side of the panel. (Note 3) Available in 2 heights: 20mm or 30mm. (Note 4) CABLES MUST BE ORDERED SEPARATELY. 27 0.51 (13) 1.08 (27.5) 1.14 (29) Cable 0.2 5( R6 .5) 4.69 (119) 1.77 (45) Flange Disconnect Handle <UF Type Handle> Dimensions of actuator parts: inch (mm) ● BZ6UF30D 4.21 (107) 3.54 (90) FAB ELB CL 3.70 (94) FAB ELB CL 0.2 dia (4-M4 or Ø 5) 5.20 (132) 6.10 (155) 30 FAB ELB CL FAB ELB CL Main unit ● BZ6UF40D 4.21 (107) 4.13 (105) FAB ELB CL FAB ELB C L 3.70 (94) 0.2 dia (4-M4 or Ø 5) 4.96 (126) 6.50 (165) 1.38 (35) FAB ELB CL FAB ELB C L Main unit ● BZ6UF60D 1.73 (44) 0. 28 6.77 (172) 5.51 (140) FAB ELB CL di a FAB ELB CL 8.46 (215) 10.12 (257) 6.14 (156) (4 -M 6 or Ø FAB ELB C L 7) FAB ELB C L Main unit (Note 1) The flange handle consists of handle operating parts and actuators parts. (Note 2) Operating parts can be installed on either right-or-left side of the panel. (Note 3) Available in 2 heights: 20mm or 30mm. (Note 4) CABLES MUST BE ORDERED SEPARATELY. 28 Flange Disconnect Handle <UF Type Handle> Dimensions of terminal covers: inch (mm) ● BZ6UTB30 3.94 (100) 2.40 (61) 2.56 (65) Terminal cover 6.10 (155) 1.18 (30) 0.7 (18) Insulation barrier 90 ● BZ6UTB40 4.53 (115) 2.40 (61) 3.15 (80) Terminal cover 6.50 (165) 1.46 (37) 1.06 (27) Insulation barrier 4.13 (105) ● BZ6UTB60 4.25 (108) 7.48 (190) 4.13 (105) Terminal cover 10.12 (257) 1.97 (50) 4.57 (116) Insulation barrier 5.51 (140) 29 30 Your local authorized stocking distributor is: Fuji Electric FA Components & Systems Co., Ltd. Mitsui Sumitomo Bank Ningyo-cho Bldg., 5-7 Nihonbashi Odemma-cho, Chuo-ku, Tokyo 103-0011, Japan Phone : +81-3-5847-8042 Fax : +81-3-5847-8172 Website : www.fujielectric.co.jp/fcs Fuji Electric Corp. of America Park 80 West Plaza II Saddle Brook, NJ 07663 Phone: 201-712-0555 Fax: 201-368-8258 Website: www.fujielectric.com I N F O R M AT I O N I N T H I S C AT A L O G I S S U B J E C T T O C H A N G E W I T H O U T N O T I C E . Printed in USA 2006/5.5M