Optical fibre cables and optoelectronic converters

advertisement
Optical fibre cables and
optoelectronic converters
INTRODUCTION
From 1988 Optral design, manufacture and commercialize
optical cables as well optoelectronic equipments for audio,
video and data signals.
Our philosophy is to supply the best cable for each
application, within the shortest possible delivery time and
with no minimum length limit.
We are specialized in design and manufacture of cables
according to the strict needs of our customers.
We are proud to be the manufacturer with the best service
in Europe, replying to any demand of our customers quickly,
giving the shorter delivery times and delivering to the
expected date.
We strive to keep our customers’ satisfaction, more of them
being customers from Optral foundation date.
p. 3
Index
TIGHT BUFFER CABLES
Patchcord CPS
FLAT
ZIPCORD / MINI ZIPCORD
Metallic Armoured CDAS
Indoor CDI
Indoor CDIR
Indoor / Outdoor CDG
Indoor / Outdoor CDAD - CDAD UL
CDAD: The authentic universal fibre optic cable
Indoor / Outdoor CDAD over the 16 F.O.
Dielectric Outdoor CDIR-AD
Metallic Outdoor CDIR-AM
Metallic Outdoor CDAM
04
04
05
05
06
06
07
07
08-09
10
10
11
11
LOOSE TUBE CABLES
Indoor / Outdoor
Indoor / Outdoor
Indoor / Outdoor
Indoor / Outdoor
Dielectric Outdoor
Dielectric Outdoor
Metallic Outdoor
NEXO (DT)
NEXO (DP)
DP
TENAX DP
PKP
DPDP
DPMP-1
DPMP
DSP-1
DSP
DPSP-1
DPSP
Self-supported ADSS 80 / 120 / 150 / 200
ADSS-50 U
CAM FIG8
12
12
13
13
14
14
15
15
16
16
17
17
18
19
19
OPTRAL SOLUTIONS FTTx LINE
FTTx CAS-S1
CAS FLAT-F1
CAR / R1
CDV / V1
CAR - R2
ADSS FLAT - F2
ABD - 01
ABD
Accessories SUBSCRIBER CONNECTION POINT SCP
KIT FTTx LINE
CABLE BOX
SOLUTION FTTx
20
20
21
21
22
22
23
23
24
24
25
26
OPTICAL FIBRES
Optical Fibres MULTIMODE OPTICAL FIBRE 62,5 / 125
MULTIMODE OPTICAL FIBRE50 / 125
SINGLEMODE OPTICAL FIBRE SMF G.652D / G.655
SINGLEMODE OPTICAL FIBRE - G.657
28
28
29
29
OPTOELECTRONIC
Optoelectronic VM1 - VIDEO
OTHER EQUIPMENTS
DM5 - SERIE RS232, RS422 AND RS485
30
30
31
p. 4
Patchcord
CPS
Tight buffer cables
Cable description
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Outer Jacket
Fire resistance
• Flame retardant
• Low smoke emission
Applications
• Indoor
• Pigtail and jumper connections
• Direct connection to terminal equipments
• Based on DIN VDE 0888 Part 4
Options
• Jackets: LSZH
• Easy-Strip Buffer
• Special Colours Code
Advantages
• Flexible / Resilient / Totally dielectric / Direct connectorization.
01. Tight Buffer Fibre
02. Aramid
03. Outer Jacket
SP
SPECIFICATIONS
1
Fibres
Thermoplastic FRLS1
Outer jacket
Orange (MM62) / Blue (MM50) / Yellow (SM)
Identification
Ou
Co
200 / 350
Tensile Load Perm / Inst (N)
We
500
Crush (N)
Temperature Range
-5 ºC to +60 ºC
Min. Bending Radius
15 x ø Outer
øO
Ten
Cru
2000 m
Max. Length
Str
±0.1
2.9
Outer ø (mm)
Tem
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794
Fire test according to: UNE-EN 50265 (IEC 60332-1) / UNE-EN 50268 (IEC 61034-1/2).
1
2
Mi
Ma
FRLS – Special PVC heavy metals free, low halogen and low smoke emission and flame retardant.
For singlemode fibre G.657 the jacket colour is ivory.
TOTALLY
DIELECTRIC
Patchcord
Ide
2
7.5
Weight (Kg/Km)
MOISTURE
PROTECTED
HIGH
FLEXIBILITY
Flat
FLAME
RETARDANT
LOW SMOKE
EMISSION
Tight buffer cables
Cable description
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Inner Jacket
• Outer Jacket
Fire resistance
• Flame retardant
• Low smoke emission
Fibres
Strength members
Outer jacket
ø Subcables diameter (mm)
Outer jacket
Applications
• Indoor
• Direct connection to terminal equipments
• Based on DIN VDE 0888 Part 4
Colour
Options
• Jackets: LSZH
• Easy-Strip Buffer
• Special Colours Code
Crush (N)
Advantages
• Flexible / Resilient / Totally dielectric / Direct connectorization.
SP
SPECIFICATIONS
Weight (Kg/Km)
Outer ø (mm)
Tensile Load Perm / Inst (N)
2
Fib
Aramid Yarns
Str
FRLS1
Inn
2.9
±0.1
Thermoplastic FRLS
Arm
1
Ou
Orange (MM62) / Blue (MM50) / Yellow (SM)
Co
27
We
3.8 x 6.7
±0.2
øO
400 / 700
Ten
750
Cru
Temperature Range
-5 ºC to +60 ºC
Tem
Min. Bending Radius
15 x ø Outer
Mi
2000 m
Ma
Max. Length
01. Tight Buffer Fibre
02. Aramid
03. Inner Jacket
04. Outer Jacket
Fib
Aramid Yarns
Strength members
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794
Fire test according to: UNE-EN 50265 (IEC 60332-1) / UNE-EN 50268 (IEC 61034-1/2).
Inner jacket colour: red, green.
1
FRLS – Special PVC heavy metals free, low halogen and low smoke emission and flame retardant.
2
For singlemode fibre G.657 the jacket colour is ivory.
p. 5
SPECIFICATIONS
Zipcord
Mini ZIP-16
Mini ZIP-21
Mini ZIP-25
Cable description
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Outer Jacket
2
Fibres
Fire resistance
• Flame retardant
• Low smoke emission
Colours
Identification
Aramid Yarns
Strength members
Thermoplastic
FRLS1
Outer jacket
LSZH
Orange (MM62) / Blue (MM50) / Yellow (SM)
Colour
15
5.5
9
12.2
2.8 x 5.9 ±0.1
1.6 x 3.4 ±0.1
2.1 x 4.4 ±0.1
2.5 x 5.3 ±0.1
400 / 700
80 / 130
240 / 400
300 / 500
500
300
300
500
Weight (Kg/Km)
ø Outer (mm)
Tensile Load Perm / Inst (N)
Crush (N)
2
Temperature Range
-5 ºC to +60 ºC
Min. Bending Radius
15 x ø Outer
Applications
• Indoor
• Pigtail and jumper connections
• Direct connection to terminal equipments
• Based on DIN VDE 0888 Part 4
Options
• Jackets: LSZH
• Easy-Strip Buffer
• Special Colours Code
03
Advantages
• Flexible / Resilient / Totally dielectric / Direct connectorization.
2000 m
Max. Length
Patchcord
Zipcord / Mini Zipcord
Tight buffer cables
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794
Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268
(IEC 61034-1/2).
Fibres colour code: red, green.
1
LSZH - Halogen free, low smoke and flame retardant thermoplastic compound.
2
For singlemode fibre G.657 the jacket colour is ivory.
01
02
01. Tight Buffer Fibre
02. Aramid
03. Outer Jacket
(Only MINI ZIPCORD)
SPECIFICATIONS
Fibres
2
4
6
8
Strength Members
Aramid Yarns
Inner jacket
Thermoplastic
Dark Grey
Colour
Tensile Load Perm / Inst (N)
Crush (N)
109
9.6
175
±0.3
12.1 ±0.3
1200 / 2150
1500
Temperature Range
-20 ºC to +70 ºC
Min. Bending Radius
20 x ø Outer
Maximum Length
Fire resistance
• Flame retardant
• Halogen free
• Low smoke emission
Thermoplastic LSZH1
Outer jacket
ø Outer (mm)
12
Corrugated Steel Armour
Armour
Weight (Kg/Km)
10
Descripción cable
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Inner Jacket.
• Metallic Armour
• Outer Jacket
4200 m
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC
61034-1/2).
Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.
1
LSZH – Halogen free, low smoke emissions and flame retardant thermoplastic compound.
Applications
• Universal (Indoor / Outdoor)
Rodent protection
• Excellent rodent resistance
Metallic Armoured
CDAS
Tight buffer cables
Options
• Jackets: PE
• Special colour code
Advantages
• Compact / Lightweight / Tough / Resistant / Easy to strip (gel free) / Reduced diameter / Direct connectorization / Saves installation costs / Excellent rodent protection.
05
01
04
03
01. Tight Buffer Fibre
02. Aramid
03. Inner Jacket.
04. Metallic Arm
our 05. Outer Jacket
p. 6
Cdi
Indoor
Tight buffer cables
Cable Description
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Outer Jacket
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
SPECIFICATIONS
Fibres
SP
2
4
6
12
Fib
Aramid Yarns
Strength Members
Arm
Thermoplastic LSZH1
Outer jacket
Ou
Orange (MM62) / Blue (MM50) / Yellow (SM)
Colour
Weight (Kg/Km)
8
19
4.5
±0.3
22
4.9
29
±0.3
5.6
37
±0.3
6.3
Co
49
±0.3
We
±0.3
øO
600 / 1000
Ten
7.3
Applications
• Indoor
• Based on DIN VDE 0888 part 6.
ø Outer (mm)
1000
Cru
Options
• Jackets: PVC / PU
• Special colour code
Temperature Range
-5 ºC to +60 ºC
Tem
Min. Bending Radius
20 x ø Outer
Mi
4200 m
Ma
400 / 700
Tensile Load Perm / Inst (N)
500 / 850
Crush (N)
Maximum Length
Advantages
• Compact / Lightweight / Flexible / Easy to strip (gel free) / Totally dielectric /Reduced diameter / Direct connectorization / Saves installation costs.
Standards
Environmental and mechanical tests according to: EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC 610341/2).
Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
1
01. Tight Buffer Fibre
02. Aramid
03. Outer Jacket
Indoor
Cdir
Tight buffer cables
Cable Description
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Individual Jacket (ø 2.5 mm)
• Outer Jacket
Fire resistance
• Flame retardant
• Halogen free
• Low smoke emission
Applications
• Indoor
• Direct connection to terminal equipments
• Based on DIN VDE 0888 part 6
Options
• Jackets: PVC / LSZH / PE / PU / PA
• Special colour code
Advantages
• Compact / Resilient / Tough / Excellent mechanical resistance / Easy to strip (gel free) / Totally dielectric / Direct connectorization.
01. Tight Buffer Fibre
02. Aramid
03. Individual Jacket
04. Outer Jacket
SPECIFICATIONS
Fibres
SP
2
4
6
8
Thermoplastic LSZH
Outer jacket
54
7.9
±0.3
54
7.9
±0.3
77
9.6
96
±0.3
11.1
± 0.5
Ou
1
Co
130
12.1
± 0.5
We
173
13.9
± 0.5
600/1000 800/1350 1200/2050 1600/2700 2400/3500 3200/3500
2000
Temperature Range
-20 ºC to +70 ºC
Min. Bending Radius
20 x ø Outer
Max. Length
Arm
Orange (MM62) / Blue (MM50) / Yellow (SM)
Colour
Crush (N)
1
Numbers
Identification
Tensile Load Perm / Inst (N)
Inn
Thermoplastic LSZH
Subcables jacket
Fib
Str
2.5
ø Subcables (mm)
ø Outer (mm)
16
Aramid Yarns
Subcables strength members
Weight (Kg/Km)
12
3200 m
Standards
Environmental and mechanical tests according to: EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267(IEC 60754-1)/UNE-EN 50268(IEC 61034-1/2).
1
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
øO
Ten
Cru
Tem
Mi
Ma
p. 7
CDG
Cable Description
• Tight Buffer Fibre (0.9 mm)
• Fiberglass Reinforcements-WB
• Outer Jacket
SPECIFICATIONS
2
Fibre count
4
6
Fire resistance
• Flame retardant
• Halogen free
• Low smoke emission
Thermoplastic LSZH1
Outer jacket
Black
Colour
34
Weight (Kg/Km)
6.0
ø Outer (mm)
Tensile Load Perm / Inst (N)
37
±0.3
6.3
42
±0.3
6.5
57
±0.3
7.5
69
± 0.3
Crush (N/100mm)
1300
Temperature range
-20 ºC to +70 ºC
Min. Bending radius
20 x ø Outer
Applications
• Universal (Indoor / Outdoor)
8.3 ± 0.3
650/1100 650/1100 650/1100 850/1450
850/1450
Rodent Protection
• Rodent Protected
Options
• Outer jacket: PVC / PU
• Special colour code
4200 m
Maximum Length
Standards
Environmental and mechanical tests according to EN 187000 and IEC 60794.
Fire tests according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267-2-1/-2 (IEC 60754-2-1/-2) / UNEEN 61034-2 (IEC 61034-2).
Fibre standard colour coding: red – green – grey – yellow – blue – natural – white – brown – violet – orange –
pink – black.
1
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
Advantages
• Compact / Lightweight / Flexible
Easy to strip ( gel free ) / Totally
dielectric Reduced diameter / Direct connectorization / Saves installation costs / Rodent protected.
01. Tight Buffer Fibre (0,9 mm)
02. Fiberglass Reinforcements-WB
03. Outer Jacket
Cable Description
• Tight Buffer Fibre (0.9 mm)
• Reinforced Fiberglass Yarns
• Inner Jacket
• Dielectric Armour
• Outer Jacket
SPECIFICATIONS
Fibres
2
4
6
Thermoplastic
Inner jacket
Thermoplastic LSZH1
Outer jacket
Black
Colour
± 0.5
0/3500
34-1/2).
ø Outer (mm)
Tensile Load Perm / Inst (N)
Crush (N)
89
9.0
±0.3
93
9.3
600 / 1100
±0.3
98
9.5
±0.3
123
10.7
700 / 1250
±0.3
141
11.5
±0.3
800 / 1800
1500
Temperature Range
-20 ºC to +70 ºC
Min. Bending Radius
20 x ø Outer
Maximum Length
Fire resistance
• Flame retardant
• Halogen free
• Low smoke emission
• Fire resistant (180 min)
Fibreglass Braid
Armour
73
12
Reinforced Fiberglass Yarns (WB)
Strength members
Weight (Kg/Km)
8
4200 m
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC
61034-1/2).
Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.
1
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
Applications
• Universal (Indoor / Outdoor)
Interior / Outdoor
Cdad - Cdad UL(Optional)
Tight buffer cables
16
9
12
Reinforced fibreglass yarns WB
Armour
61034-
8
Indoor / Outdoor
Tight buffer cables
Rodent Protection
• Rodent resistant
Options
• Jackets: PVC / PU / PA
• Special colour code
Advantages
• Compact / Lightweight / Flexible / Tough / Resistant / Easy to strip (gel free) /Totally dielectric / Reduced diameter / Direct connectorization / Saves installation costs / Rodents protected.
04
03
01
02
05
01 Tight Buffer Fibre
02 Reinforced Fiberglass Yarns
03 Inner Jacket
04 Dielectric Armour
05 Outer Jacket
p. 8
CDAD
The authentic universal fibre optic cable
Technical description
1
THE CABLE
2
Dielectric armoured distribution cable: CDAD very strong, totally dielectric and
rodent-protected. Can be used in indoor and outdoor.
Construction
3
4
1. Optical fibre
2. Tight buffer
3. Aramid strength members
4. Inner jacket
5. Fibreglass braid armour LSZH outer jacket
Advantages
5
•Very strong and resistant construction
•Direct termination
•Flexible and reliable
•Very easy to strip (gel free)
•Flame retardant (Fe180), low smoke emission and halogen free (LSZH)
•Totally dielectric
•Rodents protection
6
Fibres types
Standard
jackets
Fibre MM:
Fibre SM:
The CDAD cable, as well as all OPTRAL’s cables, can be manufactured with any optical fibres existing on
the market. This chart intends to help you to make your choice:
Fibre type
Denomination
Application
SM-9/125S/UIT G-652
SM
Standard dispersion (optimized 1300nm)
SM-9/125S/UIT G-653
SM
Displaced dispersion (long distance applications)
SM-9/125S/UIT G-655
SM
For applications DWDM
Application
Fibre type
Characteristics
Video vigilance
MM 62,5/125 S/IEC 60793
Atenuatión: 3,2 dB/K-(850), 1,0 dB/K-(1300)
Industrial Control
MM 50/125 S/IEC 60793-2
Atenuatión: 3,0 dB/K-(850), 0,9 dB/K-(1300)
Application
Fibre type
Distance (10 Gigabit Ethernet)
Data transmission
Standard MM 62,5/125 ó 50/125
MM 50/125 Máx. Cap. 150 (exceed 0M2)
MM 50/125 Máx. Cap. 300 (0M3)
Estándar SM S/UIT G-652
30m/80m
150m
300m
>2000m
Fibre type
Distance (10 Gigabit Ethernet)
Standard MM 62,5/125 ó 50/125
HiCap 62,5/125
HiCap 50/125
550m
1000m
2000m
One jacket for each application:
Polyethylene (PE): For outdoors,
very resistant to moisture and UV
rays.
Poliolefyne (LSZH): Zero halogen
material for indoors. Flame
retardant.
Polyurethane: Very flexible and
resistant to chemical agents with rip
resistance.
Nitrile rubber: Resistant to oils and
hydrocarbons.
(Others jackets on request: TEFLON,
Polyamide, PVC, etc…)
p. 9
Advantages
Antihumedad
Moisture is the main and ever-present enemy
to optical fibre. By damages in jacket or by
condensation. The double jacket of CDAD and
its tight construction convert it into a watertight
cable.
Moisture
Optical fibre
Gel
Jacket
“The double jacket of CDAD and its
tight construction convert it into a
watertight cable”
DISMANTLED FIBRE
Without axial migration
This phenomenon, usual for Loose Tube cables,
does not appear in our Tight Buffered CDAD
cable; making it suitable for vertical lays whatever
its lengths and its environment.
TWISTED AND
COMPRESSED FIBRE
Rodents protection
The double jacket and the fibreglass braid armour provide an
effective rodents protection.
Fibre, non jelly-protected
and under tension, bends
on a very acute angle. The
breaking risk is very high.
The fibre excess of all the
length accumulates on few
meters of the lower part,
increasing the attenuation
due to compression efforts
and numerous and closed
bends.
Strong and flexible
Just as can be observed in
the accompanying photos,
our CDAD cable, in spite
of its excellent flexibility,
commodity and simple
economic installation,
is, above all, extremely
strong and resistant.
1
2
3
4
1CDAD bent double and inserted between the jaws of a dynamometer.
2Cable being crushed by a pressure of 500kgs.
3Cable state after being removed from the dynamometer.
4Despite the tremendous pressure exerted on the cable, the fibre remains unaltered.
Flame resistant (Fe-180)
Fe180 denomination guarantees that a cable maintains
operating without interrupting for 3 hours at an ignition
temperature of 750ºC. (Norms: DIN-VDE 0266, IEC
60331 and UNE 20431-32). Moreover, it is a low smoke
emission and halogen free (LSZH) cable.
p. 10
Indoor / Outdoor
Cdad
over 16 Fibres
Cable Description
• Central Element (GRP)
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Jacket (Subcables)
• Dielectric Armour
• Outer Jacket
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
• Fire resistance (180 min)
05
SP
16
Fibres
24
32
36
48
64
72
4
Subcables 4 FO
6
8
Subcables jacket
Identification
9
12
16
18
Su
Numbers
Co
Thermoplastic LSZH
Outer jacket
øS
Thermoplastic
Ide
Fibreglass Braid
Armour
Fib
Su
me
Aramid Yarns
Strength Members
Inn
1
Arm
Colour
Rodent protection
• Rodent resistant
ø Outer (mm)
11.2 ±0.5 13.2 ±0.5 15.2 ±0.5 16.3 ±0.5 18.1 ±0.5 20.1 ±0.5
Tensile Load Perm/Inst (N)
800/1450 1100/2000 1400/2500 1550/2800 2200/3950 2900/4000 2900/4000
øO
1500
Ten
Temperature Range
-20 ºC to +70 ºC
Cru
Min. Bending Radius
20 x ø Outer
Tem
Advantages
• Compact / Tough / Resistant / Easy to strip (gel free) / Totally dielectric / Direct connectorization / Saves installation costs / Rodent protected.
01
SPECIFICATIONS
Applications
• Universal (Indoor / Outdoor)
Options
• Jackets: PVC / PU / PA
• Special colour code
06
Tight buffer cables
Dark Grey / Black
116
Weight (Kg/Km)
164
220
Crush (N)
258
280
347
353
20.1 ±0.5
1800 m
Maximum Length
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266(IEC 60332-3) / UNE-EN 50267(IEC 60754-1) / UNE-EN 50268(IEC 61034-1/2)
Fibres colour code: red, green, grey , yellow.
1
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
Ou
Co
We
Mi
Ma
Stand
Enviro
Fire te
1
LSZH
03
02
04
01. Central Element (GRP)
02. Tight Buffer Fibre
03. Aramid
04. Jacket (Subcables)
05. Dielectric Armour
06. Outer Jacket
Dielectric Outdoor
Cdir-ad
Cable Description
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Individual Jacket (ø 2.5 mm)
• Inner Jacket
• Dielectric Armour
• Outer Jacket
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
Applications
• Universal (Indoor / Outdoor)
• Direct connection to terminal equipments
Rodent protection
• Rodent resistant
05
04
01
03
02
06
01. Tight Buffer Fibre
02. Aramid
03. Individual Jacket
04. Inner Jacket
05. Dielectric Armour
06. Outer Jacket
Tight buffer cables
SPECIFICATIONS
Fibres
Subcables strength members
ø Subcables (mm)
Subcables Jacket
Identification
Inner jacket
Armour
Outer jacket
Colour
Weight (Kg/Km)
ø Outer (mm)
Options
• Jackets: PVC / PE / PU / PA
• Special colour code
• Buffer Easy-Strip
Tensile Load Perm / Inst (N)
Advantages
• Compact / Flexible / Resilient / Tough / Excellent mechanical resistant / Easy to strip (gel free) / Totally dielectric / Direct connectorization / Rodent protected.
Min. Bending Radius
Crush (N)
Temperature Range
Maximum Length
SP
2
4
6
8
12
16
Aramid Yarns
2.5
Thermoplastic
Numbers
Thermoplastic
Fiberglass Braid
Thermoplastic LSZH1
Orange (MM62) / Blue (MM50) / Yellow (SM)
110
121
167
197
240
287
± 0.5
± 0.5
13.0
± 0.5
± 0.5
10.9
10.9
± 0.5
14.5
15.5
17.1 ± 0.5
800/1450 1000/1800 1400/2500 1800/3250 2600/4000 3000/4000
2000
-20 ºC to +70 ºC
20 x ø Outer
3200 m
Standards
Environmental and mechanical tests according to: EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266(IEC 60332-3) / UNE-EN 50267(IEC 60754-1) / UNE-EN 50268(IEC 61034-1/2)
1
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
Fib
Str
Inn
Arm
Ou
Co
We
øO
Ten
Cru
Tem
Mi
Ma
p. 11
SPECIFICATIONS
4
6
Subcables strength
members
ø Subcables (mm)
Subcables jacket
Colour
Identification
Inner jacket
Armour
Outer jacket
3
1 ±0.5
00/4000
Colour
Weight (Kg/Km)
ø Outer (mm)
Tensile Load Perm / Inst (N)
Crush (N)
Temperature Range
Min. Bending Radius
Max. Length
034-1/2)
8
12
16
Aramid Yarns
2.5
Thermoplastic
Orange (MM62) / Blue (MM50) / Yellow (SM)
Numbers
Thermoplastic LSZH1
Steel Wires Braid
Thermoplastic LSZH1
Orange (MM62) / Blue (MM50) / Yellow (SM)
123
135
183
218
263
372
10.9 ±0.5 10.9 ±0.5 13.0 ±0.5 14.5 ±0.5 15.5 ±0.5 17.3 ±0.5
900/1600 1100/2000 1500/2700 1900/3400 2700/4000 3000/4000
2000
-20 ºC to +70 ºC
20 x ø Outer
4200 m
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266(IEC 60332-3)/UNE-EN 50267(IEC 60754-1)/UNE-EN 50268(IEC 61034-1/2).
1
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
Cdir-am
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
Applications
• Outdoor
• Direct connection to terminal equipments
Rodent protection
• Excellent rodent resistance
Options
• Jackets: PVC / PE / PU / PA
• Special colour code
• Buffer Easy-Strip
05
01
04
Advantages
• Compact / Flexible / Resilient / Tough / Excellent mechanical resistance / Easy to strip (gel free) / Direct connectorization / Excellent rodent protection.
03
06
02
01. Tight Buffer Fibre
02. Aramid
03. Individual Jacket
04. Inner Jacket
05. Metallic Armour
06. Outer Jacket
SPECIFICATIONS
Fibres
2
4
Thermoplastic LSZH1
Outer jacket
Black
Colour
0/4000
034-1/2)
Tensile Load Perm / Inst (N)
Crush (N)
98
104
111
133
9.0 ±0.3
9.3 ±0.3
9.5 ±0.3
10.7 ±0.3
700 / 1250
800 / 1450
157
11.5 ±0.3
900 / 1600
1500
Temperature Range
-20 ºC to +70 ºC
Min. Bending Radius
20 x ø Outer
Maximum Length
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
Steel Wires Braid
Armour
± 0.5
12
Thermoplastic
Inner jacket
ø Outer (mm)
8
Reinforced Fiberglass Yarns (WB)
Strength Members
Weight (Kg/Km)
6
Cable Description
• Tight Buffer Fibre (0.9 mm)
• Reinforced Fiberglass Yarns
• Inner Jacket.
• Metallic Armour
• Outer Jacket
4200 m
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC
61034-1/2).
Fibres colour code: red, green, grey, yellow, blue, natural, white, brown, violet, orange, pink, black.
1
LSZH – Halogen free, low smoke emissions and flame retardant thermoplastic compound.
Applications
• Universal (Indoor / Outdoor)
Metallic Outdoor
Cdam
Tight buffer cables
16
1
2
Fibres
Cable Description
• Tight Buffer Fibre (0.9 mm)
• Aramid
• Individual Jacket (ø 2.5 mm)
• Inner Jacket
• Metallic Armour
• Outer Jacket
Metallic Outdoor
Tight buffer cables
Rodent protection
• Excellent rodent resistance
Options
• Jackets: PVC / PU / PA
• Special colour code
Advantages
• Compact / Lightweight / Flexible / Tough / Resistant / Easy to strip (gel free) /Reduced diameter / Direct connectorization / Saves installation costs / Excellent rodent protection.
03
04
01
05
02
01. Tight Buffer Fibre
02. Reinforced Fiberglass Yarns
03. Inner Jacket.
04. Metallic Armour
05. Outer Jacket
p. 12
Indoor / Outdoor
Nexo
Cable Description
• Fibres Optics
• Central Tube (Jelly filled)
• Fiberglass Reinforcements - WB
• Ripcord
• Outer Jacket
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
SP
SPECIFICATIONS
Fibres
2
4
6
8
Fib
24
4.2
Thermoplastic LSZH
Outer jacket
± 0.2
Fib
Tot
1
Ac
Str
Dark Grey
Colour
53
Weight (Kg/Km)
Crush (N)
16
Fiberglass Reinforcements WB (Waterblocking)
Strength members
Rodent protection
• Rodent protected
12
± 0.2
3.2
ø Central Tube (mm)
ø Outer (mm)
Advantages
• Compact / Lightweight / Flexible / Tough / Resistant / Totally dielectric / Watertight / Reduced diameter / Rodent protected.
03
Loose tube cables
Applications
• Universal (Indoor / Outdoor)
Options
• Strength Members: Aramid (KT Type)
• Special colour code (TIA 598)
02
05
(DT)
7.0
Co
60
± 0.3
7.9
± 0.3
Co
1000 / 180
We
1500
øO
Temperature Range
-30º C to +70º C
Ten
Ins
Min. Bending Radius
20 x ø Outer
Tensile Load Perm / Inst (N)
Cru
4000 m
Maximum Length (m)
2000 m
Ma
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fire test according to: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-1) / UNE-EN 50268 (IEC
61034-1/2).
Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red,
green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.
1
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
Tem
Mi
04
01
01. Fibres Optics
02. Central Tube (Jelly filled)
03. Fiberglass Reinforcements - WB
04. Ripcord
05. Outer Jacket
Indoor / Outdoor
Nexo
02
03
05
04
01
01. Fibre Optics
02. Central Tube (Jelly filled)
03. Fiberglass Reinforcements - WB
04. Ripcord
05. Outer Jacket
(DP)
Cable Description
• Fibre Optics
• Central Tube (Jelly filled)
• Fiberglass Reinforcements - WB
• Ripcord
• Outer Jacket
Applications
• Outdoor
Rodent protection
• Rodent protected
Loose tube cables
SPECIFICATIONS
Fibres
ø Central Tube (mm)
Strength members
Outer jacket
SP
2
4
6
3.2
8
Weight (Kg/Km)
24
4.2
± 0.2
Fib
øC
Str
Lineal Low Density Polyethylene
Ou
Black
Co
40
7.0
50
± 0.3
7.9
± 0.3
Tensile Load Perm / Inst (N)
Temperature Range
-40º C to +70º C
Advantages
• Compact / Lightweight / Flexible Tough / Resistant / Totally dielectric / Watertight / Reduced diameter / Excellent resistance to friction / Suitable for “blown air” system / Rodent protected.
Min. Bending Radius
20 x ø Outer
1500
Crush (N)
4000 m
We
øO
Ten
Ins
1000 / 1800
Options
• Strength Members = Aramid (KP Type)
• Special colour code (TIA 598)
Maximum Length (m)
16
Reinforced Fiberglass yarns WB (Waterblocking)
Colour
ø Outer (mm)
12
± 0.2
Cru
Tem
Min
2000 m
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red,
green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.
Ma
DP
SPECIFICATIONS
16
24
32
36
48
64
72
96
Fibres per Tube
4
6
8
6
12
8
12
Total Tubes
4
4
4
6
4
8
6
Active Tubes
4
4
4
6
4
8
6
Fibre Count
128
144
12
8
12
8
18
14
8
16
12
Applications
• Outdoor
Reinforced Fiberglass Yarns WB (Waterblocking)
Strength members
Lineal Low Density Polyethylene
Compound
Black
Colour
63
Weight (Kg/Km)
64
74
82
84
134
119
157
194
181
9.3±0.5 9.3±0.5 10.2±0.5 10.5±0.5 11.0±0.5 13.2±0.5 12.6±0.5 14.3±0.5 16.7±0.5 17.0±0.5
ø Outer (mm)
Tensile Load Perm /
Inst (N)
1000 / 1800
1500 / 2700
2000
Crush (N)
Maximum Length (m)
4200 4200 3100 4200 2100 3100 2100 2100 3100 2100
Temperature Range
-40º C to +70º C
Min. Bending Radius
20 x ø Outer
Cable Description
• Central Element (GRP)
• Fibre Optics
• Loose Tube (Jelly Filled)
• Fiberglass Reinforcements - WB
• Ripcord
• Outer Jacket
Rodent protection
• Rodent protected
Indoor / Outdoor
Loose tube cables
Options
• Strength Members = Aramid (KP Type)
• Special colour code (TIA 598)
Advantages
• Compact / Tough / Resistant / Totally dielectric / Excellent resistance to friction / Suitable for “blown air” system.
04
03
02
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.
06
05
01
01 Central Element (GRP)
02 Fibre Optics
03 Loose Tube (Jelly Filled)
04 Fiberglass Reinforcements - WB
05 Ripcord
06 Outer Jacket
Tenax DP
Loose tube cables
SPECIFICATIONS
Fibre Count
ø Central Tube (mm)
Strength members
2
4
6
3.2
8
Tensile Load Perm /
Inst (N)
Min. Bending Radius
Maximum Length (m)
4.2
Applications
• Outdoor
• Aerial Installation
Black
67
8.4
77
± 0.3
9
± 0.3
3000 / 4000
1500
Crush (N/10cm)
Temperature Range
24
± 0.2
Polyethylene
Colour
ø Outer (mm)
16
Fiberglass yarns WB (Waterblocking)
Outer jacket
Weight (Kg/Km)
12
± 0.2
-40º C to +70º C
20 x ø Outer
4000 m
Cable Description
• Fibre Optics
• Central Tube (Jelly filled)
• Fiberglass Reinforcements – WB
• Ripcord
• Outer Jacket
2000 m
Standards
Environmental and mechanical tests according to EN 187000 and IEC 60794.
Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With black ring:
red, green,
yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.
Rodent protection
• Rodent Protected
Options
• Special colour code (TIA 598)
Advantages
• Compact / Lightweight / Flexible / Tough / Resistant / Watertight / Exce
llent mechanical resistance / Com
pletely Dielectric / Small diameter / Excellent resistance to friction /
Suitable for “air blowing” systems / Rodent protected / Aerial installation.
Aerial Installation Conditions
Wind
Ice Thickness
Span
(Km/h) (mm)
(m)
100 0 110
0 10 90
0 15 50
60 10 70
NESC Installation Conditions
Span (m)
NESC Light
100
NESC Medium
60
Indoor / Outdoor
d,
p. 13
02
03
04
01
01. Fibre Optics
02. Central Tube (Jelly filled)
03. Fiberglass Reinforcements – WB
04. Ripcord
05. Outer Jacket
p. 14
Dielectric Outdoor
PKP
05
Loose tube cables
Cable Description
• Central Element (GRP)
• Fibre Optics
• Loose tube (jelly filled)
• Ripcord
• Inner Jacket
• Aramid
• Ripcord
• Outer Jacket
Applications
• Outdoor
Options
• Strength Members: Reinforced fiberglass yarns
• Special colour code (TIA 598)
Advantages
• Excellent mechanical resistance / Totally dielectric / Resistant / Tough / High density of fibres / Excellent resistance to friction.
03
06
02
SPECIFICATIONS
SP
Fibre Count
4
6
8
12
16
24
32
36
48
64
72
96
128
144
Fib
Fibres per tube
4
2
4
4
4
6
8
6
12
8
12
12
8
12
øC
Total tubes
4
4
4
4
4
4
4
6
4
8
6
8
18
14
Active tubes
1
3
2
3
4
4
4
6
4
8
6
8
16
12
Inn
Lineal Low Density Polyethylene
Inner jacket
Arm
Aramid Yarns
Strength Members
Ou
Lineal Low Density Polyethylene
Outer jacket
Co
Black
Colour
Weight (Kg/Km)
ø Outer (mm)
Str
83
86
84
86
87
88
101
We
109
113
169
152
195
238
225
11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 11.1±0.5 12.0±0.5 12.3±0.5 12.8±0.5 15.0±0.5 14.4±0.5 16.1±0.5 18.5±0.5 18.8±0.5
TensileloadPerm/
Inst(N)
1000
1000
1000
1000
1000
1000
1000
1000
1500
1500
1500
1500 1500
4200
4200
4200
4200
4200
4200
3100
4200
Ten
Ins
Cru
2000
Crush (N)
Max. Length
1000
øO
2100
3100
2100
2100
3100 2100
Tem
Temperature range
-40º C to +70ºC
Min
Min. Bending radius (mm)
20 x ø Outer
Ma
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
07
04
01
01. Central Element (GRP)
02. Fibre Optics
03. Loose tube (jelly
filled)
04. Ripcord
05. Inner Jacket
06. Aramid
07. Ripcord
08. Outer Jacket
Dielectric Outdoor
DPDP
Cable Description
• Central Element (GRP)
• Fibre Optic
• Loose Tube (Jelly Filled)
• Fiberglass Reinforcements - WB
• Ripcord
• Inner Jacket
• Dielectric Armour
• Ripcord
• Outer Jacket
Applications
• Outdoor
Options
• Strength Members = Aramid (KPDP Type)
• Special colour code (TIA 598)
03
04
02
05
08
06
01
01. Central Element (GRP)
02. Fibre Optic
03. Loose Tube (Jelly Filled)
04. Fiberglass Reinforcements - WB
05. Ripcord
06. Inner Jacket
07. Dielectric Armour
08. Ripcord
09. Outer Jacket
SPECIFICATIONS
SP
16
24
32
36
48
64
72
96
128
144
Fib
Fibres per Tube
4
6
8
6
12
8
12
12
8
12
Fib
Total Tubes
4
4
4
6
4
8
6
8
18
14
Tot
Active Tubes
4
4
4
6
4
8
6
8
16
12
Ac
Fibres
Strength Members
Reinforced Fiberglass Yarns WB (Water Blocking)
Str
Lineal Low Density Polyethylene
Inn
Fiberglass Braid
Arm
Inner jacket
Armour
Outer jacket
Lineal Low Density Polyethylene
Ou
Black
Co
Colour
Rodent protection
• Rodent resistant
07
Loose tube cables
Advantages
• Compact / Tough / Resistant / Totally dielectric / Excellent Resistance to Friction /
Suitable for “blown air” system / Moderate rodent protection
Weight (Kg/Km)
ø Outer (mm)
Tensile Load Perm / Inst (N)
Crush (N)
Maximum Length (m)
112
±0.5
11.9
112
±0.5
11.9
127
±0.5
12.8
135
±0.5
13.1
139
198
±0.5
13.6
±0.5
15.8
181
±0.5
15.2
1200 / 2150
225
±0.5
16.9
271
±0.5
19.3
259
±0.5
19.6
Cru
3000
3100 2100 2100 3100
Temperature Range
-40º C to +70º C
Min. Bending Radius
20 x ø Outer
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.
øO
Ten
1700 / 3050
4200 4200 3100 4200 2100
We
2100
Ma
Tem
Mi
p. 15
SPECIFICATIONS
144
12
14
12
2
Fibres
4
3.2
ø Central Tube (mm)
6
±0.2
/ 3.5
8
±0.2
(12 FO)
Applications
• Outdoor
Lineal Low Density Polyethylene
Black
96 / 101 (12 FO)
Weight (Kg/Km)
9.8
ø Outer (mm)
± 0.5
/ 10.1
± 0.5
Tensile load Perm /
Inst (N)
Rodent protection
• Excellent rodent resistence
117
(12 FO)
11.1
± 0.5
Options
• Strength Members = Aramid (KPMP-
1 Type)
• Special colour code (TIA 598)
1300 / 2350
2000
Crush (N)
2100
4.5
Steel Wire Braid
Colour
1500
24
±0.2
Lineal Low Density Polyethylene
Inner jacket
Outer jacket
18.8±0.5
16
Fibras Vidrio Reforzadas WB (Bloqueantes Agua)
Strength Members
Armour
225
12
-40º C to +70ºC
Temperature range
20 x ø Outer
Min.Bending radius (mm)
4200 m / 3200 m (12 FO)
Max. Length
Cable Description
• Fibre Optics
• Central Tube (Jelly filled)
• Fiberglass Reinforcements - WB
• Ripcord
• Inner Jacket
• Metallic Armour
• Ripcord
• Outer Jacket
Metallic Outdoor
DPMP-1
Loose tube cables
2000 m
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red,
green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.
05
Advantages
• Compact / Lightweight / Flexible / Tough / Resistant / Reduced diameter / Watertight / Excellent Resistance to Friction / Suitable for “blown air” system / Excellent rodent resistance.
02
03
07
06
01 04
01. Fibre Optics
02. Central Tube (Jelly filled)
03. Fiberglass Reinforcements - WB
04. Ripcord
05. Inner Jacket
06. Metallic Armour
07. Ripcord
08. Outer Jacket
SPECIFICATIONS
144
16
24
32
36
48
64
72
96
128
144
12
Fibres per Tube
4
6
8
6
12
8
12
12
8
12
14
Total Tubes
4
4
4
6
4
8
6
8
18
14
12
Active Tubes
4
4
4
6
4
8
6
8
16
12
Fibres
Lineal Low Density Polyethylene
Inner jacket
Lineal Low Density Polyethylene
Outer jacket
Black
Colour
259
9.6±0.5
ø Outer (mm)
Tensile Load Perm / Inst (N)
Crush (N)
Maximum Length (m)
Applications
• Outdoor
Steel Wire Braid
Armour
Weight (Kg/Km)
2100
Reinforced Fiberglass Yarns WB (Water Blocking)
Strength Members
128
128
144
153
158
223
205
257
309
298
11.9±0.5 11.9±0.5 12.8±0.5 13.1±0.5 13.6±0.5 15.8±0.5 15.2±0.5 16.9±0.5 19.3±0.5 19.6±0.5
1300 / 2350
1800 / 3250
3000
4200 4200 3100 4200 2100 3100 2100 2100 3100 2100
Temperature Range
-40º C to +70º C
Min. Bending Radius
20 x ø Outer
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.
Cable Description
• Central Element (GRP)
• Fibre Optics
• Loose Tube (Jelly Filled)
• Fiberglass Reinforcements - WB
• Ripcord
• Inner Jacket
• Metallic Armour
• Ripcord
• Outer Jacket
DPMP
Metallic Outdoor
Loose tube cables
Rodent protection
• Excellent rodent resistence
Options
• Strength Members = Aramid (KPMP Type)
• Special colour code (TIA 598)
04
03
06
Advantages
• Compact / Tough / Resistant / Excellent Resistance to Friction /
Suitable for “blown air” system / Excellent rodent protection.
02
05
08
07
01
01. Central Element (GRP)
02. Fibre Optics
03. Loose Tube (Jelly Filled)
04. Fiberglass Reinforcements - WB
05. Ripcord
06. Inner Jacket
07. Metallic Armour
08. Ripcord
09. Outer Jacket
p. 16
Metallic outdoor
DSP-1
Cable Description
• Fibre Optics
• Central Tube (Jelly filled)
• Fiberglass Reinforcements - WB
• Metallic Armour
• Ripcord
• Outer Jacket
Applications
• Outdoor
Rodent protection
• Excellent rodent resistance
Options
• Strength Members = Aramid Yarns (KSP-1 Type)
• Special colour code (TIA 598)
Advantages
• Compact / Tough / Resistant / Reduced diameter / Watertight / Excellent resistance to friction / Suitable for “blown air” system / Excellent resistance to rodents.
02
06
03
04
Loose tube cables
SPECIFICATIONS
SP
2
Fibres
4
6
8
4.5
ø Central Tube (mm)
Strength Members
12
16
24
±0.2
Fib
øC
Reinforced Fiberglass Yarns WB (Waterblocking)
Str
Corrugated Steel Armour
Inn
Lineal Low Density Polyethylene
Arm
Armour
Outer jacket
Colour
Black
Ou
88
Co
Weight (Kg/Km)
9.6
ø Outer (mm)
Tensile Load Perm / Inst (N)
±0.3
We
1500 / 2700
øO
2000
Ten
Temperature Range
-40º C to +70ºC
Cru
Min. Bending Radius
20 x ø Outer
Tem
Maximum Length
2000 m
Mi
Crush (N)
Ma
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red,
green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.
05
01
01. Fibre Optics
02. Central Tube (Jelly filled)
03. Fiberglass Reinforcements - WB
04. Metallic Armour
05. Ripcord
06. Outer Jacket
Metallic outdoor
DSP
Loose tube cables
Cable Description
• Central Element (GRP)
• Fibre Optics
• Loose Tube (Jelly Filled)
• Fiberglass Reinforcements - WB
• Metallic Armour
• Ripcord
• Outer Jacket
Applications
• Outdoor
03
06
02
05
01
01. Central Element (GRP)
02. Fibre Optics
03. Loose Tube (Jelly Filled)
04. Fiberglass Reinforcements - WB
05. Metallic Armour
06. Ripcord
07. Outer Jacket
16
24
32
36
48
64
72
96
Fibres per Tube
4
6
8
6
8
8
12
12
8
12
Fib
Total Tubes
4
4
6
6
6
8
8
8
18
14
Tot
Active Tubes
4
4
4
6
6
8
6
8
16
12
Act
Fibres
Strength Members
Rodent protection
• Excellent rodent resistance
Advantages
• Compact / Tough / Resistant / Excellent resistance to friction / Suitable for “blown air” system / Excellent rodent protection.
ø Outer (mm)
Tensile Load Perm / Inst (N)
Crush (N)
Maximum Length (m)
98
±0.5
10.0
Str
Inn
Lineal Low Density Polyethylene
Arm
Black
Out
98
±0.5
10.0
Fib
Corrugated Steel Armour
Colour
Weight (Kg/Km)
128 144
Reinforced Fiberglass Yarns WB (Waterblocking)
Armour
Outer jacket
Options
• Strength Members = Aramid
(KSP Type)
• Special colour code (TIA 598)
04
SP
SPECIFICATIONS
143
±0.5
12.5
148
148
±0.5
12.5
±0.5
12.5
220
±0.5
16.0
215
±0.5
16.0
222
±0.5
16.0
269 261
±0.5
18.5
±0.5
18.5
Col
We
2000 / 3600
øO
2500
Ten
4200 4200 3100 3100 3100 2100 2100 2100 3100 2100
Cru
Temperature Range
-40º C to +70º C
Ma
Min. Bending Radius
20 x ø Outer
Tem
Min
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.
p. 17
SPECIFICATIONS
24
2
Fibres
4
6
3.2
ø Central Tube (mm)
8
12
16
±0.2
24
4.5
±0.2
Reinforced Fiberglass Yarns WB (Waterblocking)
Strength Members
Lineal Low Density Polyethylene
Inner jacket
Corrugated Steel Armour
Armour
Black
Colour
95
135
9.6 ±0.3
12.6 ±0.5
Weight (Kg/Km)
ø Outer (mm)
Rodent protection
• Excellent rodent resistance
Options
• Strength Members = Aramid
(KPSP-1 Type)
• Special colour code (TIA 598)
1500 / 2700
Tensile Load Perm / Inst (N)
2000
Crush (N)
-40º C to +70ºC
Temperature Range
05
20 x ø Outer
Min. Bending Radius
4000 m
Maximum Length
DPSP-1
Applications
• Outdoor
Lineal Low Density Polyethylene
Outer jacket
Cable Description
• Fibre Optics
• Central Tube (Jelly filled)
• Fiberglass Reinforcements - WB
• Ripcord
• Inner Jacket
• Metallic Armour
• Ripcord
• Outer Jacket
Metallic outdoor
Loose tube cables
2000 m
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: Red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise. With stripe: red,
green, yellow, blue, white, violet, orange, natural, grey, brown, pink, turquoise.
02
Advantages
• Compact / Tough / Resistant / Watertight / Excellent resistance to friction / Suitable for “blown air”
system / Excellent resistance to rodents.
03
06
01 04
01. Fibre Optics
01. FIBRAS
ÓPTICAS
02. Central
Tube (Jelly filled)
02. MONOTUBO
CENTRAL
RELLENO DE
GEL
03. Fiberglass
Reinforcements
- WB
04. Ripcord
03. FIBRAS
VIDRIO REFORZADAS – WB
05. Inner Jacket
04. CUBIERTA
TERMOPLÁSTICA INTERIOR
06. Metallic Armour
05. ARMADURA
07. Ripcord ACERO CORRUGADO
06. CUBIERTA
TERMOPLÁSTICA EXTERIOR
08. Outer Jacket
SPECIFICATIONS
44
Fibres
16
24
32
36
48
64
72
96
128
2
Fibres per Tube
4
6
8
6
8
8
12
12
8
12
4
Total Tubes
4
4
6
6
6
8
8
8
18
14
2
Active Tubes
4
4
4
6
6
8
6
8
16
12
Reinforced Fiberglass Yarns WB (Waterblocking)
Strength Members
Lineal Low Density Polyethylene
Inner jacket
Corrugated Steel Armour
Armour
±0.5
8.5
100
Black
Colour
Weight (Kg/Km)
ø Outer (mm)
Tensile Load Perm / Inst (N)
Crush (N
Maximum Length (m)
Applications
• Outdoor
Lineal Low Density Polyethylene
Outer jacket
61
144
140
141
191
195
196
274
265
272
336
327
12.5±0.5 12.5±0.5 15.3±0.5 15.3±0.5 15.3±0.5 18.3±0.5 18.3±0.5 18.3±0.5 21.4±0.5 21.4±0.5
2000 / 3600
3000
4200 4200 3100 3100 3100 2100 2100 2100 3100 2100
Temperature Range
-40º C to +70º C
Min. Bending Radius
20 x ø Outer
Standards
Environmental and mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.
Cable Description
• Central Element (GRP)
• Fibre Optics
• Loose Tube (Jelly Filled)
• Fiberglass Reinforcements WB
• Ripcord
• Inner Jacket
• Metallic Armour
• Ripcord
• Outer Jacket
DPSP
Metallic outdoor
Loose tube cables
Rodent protection
• Excellent rodent resistance
Options
• Strength Members = Aramid
(KPSP Type)
• Special colour code (TIA 598)
03
04
04
Advantages
• Compact / Tough / Resistant / Excellent resistance to friction / Suitable for “blown air” system / Excellent rodent protection.
02
05
07
01
01. Central Element (GRP)
02. Fibre Optics
03. Loose Tube (Jelly Filled)
04. Fiberglass Reinforcements WB
05. Ripcord
06. Inner Jacket
07. Metallic Armour
08. Ripcord
09. Outer Jacket
p. 18
Self-supported
ADSS
80 / 120 / 150 / 200
Cable Description
• Central Filler
• Fibre Optics
• Loose tube (jelly filled)
• Inner jacket
• Aramid
• Ripcord
• Outer jacket
Aerial Installation Conditions (1)
Wind
Ice
Span (m)
(Km/h) (mm)
80m
120m
100
0
100
135
0
10
100
140
0
15
60
80
60
10
80 105
Applications
• Aerial Installations
Options
• Anti-Tracking Jacket
• Ballistic Protection
• Special Colour Code (TIA 598)
05
Aerial loose tube
SP
Fib
150m
195
205
115
150
200m
250
270
155
200
NESC Aerial Installation Conditions( (1)
Span
80m
120m
150m
NESC Light
100
135
190
NESC Medium
80
105
150
200m
255
200
06
Tot
Str
Ou
Co
We
øO
Ma
(1) Typical values for a 48 fibres cable.
MA
Advantages
• Excellent mechanical resistance / Totally dielectric / Tough / Resistant / High density of fibres / Self-supported aerial applications.
03
Fib
ED
Im
Tem
Mi
02
04
07
01
01. Central Filler
02. Fibre Optics
03. Loose tube (jelly filled)
04. Inner jacket
05. Aramid
06. Ripcord
07. Outer jacket
Environmental and Mechanical Tests according to EN 187000 and IEC 60794.
Fibres Colours: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.
Max. Induced Voltage = 12 KV
SPECIFICATIONS
Vano Máximo
Fibres
Fibres per Tube
Total Tubes
4
2
6
6
2
6
Inner Jacket
Strength Members
Outer Jacket
Colour
MAT (N)
EDS (N)
Impact
Temperature Range
Min. Bending Radius
Weight (Kg/Km)
ø Outer
Maximum Length
80 m: 3000
80 m: 1200
8
2
6
12
2
6
80 m |
16
4
6
120 m | 150 m | 200 m
24
32
36
48
4
8
6
8
6
6
6
6
Polyethylene
Aramid Yarns
Polyethylene
Black
120 m: 4000
150 m: 6000
80 m: 1600
80 m: 2400
5J
-40º C to +70º C
20 x ø Outer
64
8
8
72
12
6
96
12
8
200 m: 8000
80 m: 3200
111
113
115
120
12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5
3200
3200
3200
3200
80 m
116
120
133
121
139
175
141
177
12.4 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 15 ± 0.5 13.3 ± 0.5 15 ± 0.5
3200
3200
2100
3200
2100
2100
2100
2100
113
115
117
122
12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5 12.4 ± 0.5
3200
3200
3200
3200
120 m
118
123
133
123
142
177
143
179
12.4 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 12.4 ± 0.5 13.3 ± 0.5 15 ± 0.5 13.3 ± 0.5 15 ± 0.5
3200
3200
2100
3200
2100
2100
2100
2100
SP
Sp
Fib
Sel
Str
Ou
Co
We
øO
MA
Weight (Kg/Km)
ø Outer
Maximum Length
Weight (Kg/Km)
ø Outer
Maximum Length
Weight (Kg/Km)
ø Outer
Maximum Length
150 m
118
120
123
127
123
128
141
128
147
182
148
184
12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 12.7 ± 0.5 13.6 ± 0.5 12.7 ± 0.5 13.6 ± 0.5 15.3 ± 0.5 13.6 ± 0.5 15.3 ± 0.5
3200
3200
3200
3200
3200
3200
2100
3200
2100
2100
2100
2100
200 m
123
125
127
132
128
132
145
133
151
186
153
188
12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 12.8 ± 0.5 13.7 ± 0.5 12.8 ± 0.5 13.7 ± 0.5 15.3 ± 0.5 13.7 ± 0.5 15.3 ± 0.5
3200
3200
3200
3200
3200
3200
2100
3200
2100
2100
2100
2100
ED
Tem
Mi
p. 19
SPECIFICATIONS
Fibres
4
6
8
12
16
24
32
36
48
64
72
96
Fibres per Tube
2
2
2
2
4
4
8
6
8
8
12
12
Total Tubes
6
6
6
6
6
6
6
6
6
8
6
8
Strength Members
Aramid Yarns
Outer Jacket
Polyethylene
Applications
• Aerial Installations
Black
Colour
68
Weight (Kg/Km)
±0.5
69
±0.5
9.7
70
±0.5
9.7
73
71
±0.5
9.7
73
±0.5
9.7
87
±0.5
±0.5
10.9
74
±0.5
119
±0.5
±0.5
94
121
±0.5
10.9 12.4 10.9 12.4±0.5
9.7
Maximum Length (mm)
3200 3200 3200 3200 3200 3200 2100 3200 2100 2100 2100 2100
MAT (N)
2000
EDS (N)
800
9.7
92
ø Outer (mm)
9.7
5J
Impact
Cable Description
• Central Filler
• Fibre Optics
• Loose tube (jelly filled)
• Aramid
• Ripcord
• Outer jacket
Temperature Range
-40º C to +70ºC
Min. Bending Radius
20 x ø Outer
Environmental and Mechanical Tests according to EN 187000 and IEC 60794.
Fibres Colours: Red, green, blue, yellow, grey, violet, brown, orange, white, pink, black and natural.
Max. Induced Voltage = 12 KV
Options
• Ballistic Protection
• Special Colour Code (TIA 598)
Advantages
• Excellent mechanical resistance / Totally dielectric / Tough / Resistant / High density of fibres / Self-supported aerial applications.
Self-supported Loose tube
ADSS-50u
Aerial loose tube
04
Aerial Installation Conditions (1)
Wind
Ice
Span
(Km/h) (mm)
(m)
100
0
90
0
10
80
0
15
45
60
10
60
02
06
NESCAerial Installation Conditions( (1)
Span
NESC Light
80
NESC Medium
55
05
01
01. Central Filler
02. Fibre Optics
03. Loose tube (jelly filled)
04. Aramid
05. Ripcord
06. Outer jacket
(1) Typical values for a 48 fibres cable.
SPECIFICATIONS
Fibres
Self-supporting Element
Strength Members
Outer Jacket
Colour
Weight (Kg/Km)
ø Outer Diameter (mm)
MAT (N)
EDS (N)
80 m
Up to 24
Steel Messenger 4.0 mm
Aramid Yarns
Lineal High Density Polyethylene
Black
185
16.0 x +7.0 ±0.5
5700
2250
Temperature Range
-40º C to + 70º C
Min. Bending Radius
20 x ø Outer
Environmental and mechanical tests according to EN 187000 and IEC 60794.
Fibres Colour: Red - Green - Blue - Yellow - Grey - Violet - Brown - Orange - White - Pink - Black - Turquoise - Red
1 stripe - Green 1 stripe - Blue 1 stripe - Yellow 1 stripe - White 1 stripe - Violet 1 stripe - Orange 1 stripe - Natural
1 stripe - Grey 1 stripe - Brown 1 stripe - Pink 1 stripe - Turquoise 1 stripe.
Cable Description
• Fibre Optic
• Loose tube (jelly filled)
• Aramid
• Steel Messenger
• Outer Jacket
Applications
• Aerial Installations
Options
• Anti-Tracking Jacket
Self-supported
CAM-Figura 8
Aerial loose tube
Span Max
03
Advantages
• Excellent mechanical resistance / Tough / Resistant / Self-supported aerial applications.
Aerial Installation Conditions (1)
Wind
Ice
Span
(Km/h) (mm)
(m)
100
0
110
0
10
185
0
15
105
60
10
105
NESC Aerial Installation Conditions( (1)
Span
NESC Light
115
NESC Medium
105
(1) Typical values for a 48 fibres cable..
01
02
03
05
04
01. Fibre Optic
02. Loose tube (jelly filled)
03. Aramid
04. Steel Messenger
05. Outer Jacket
p. 20
Indoor
CAS - S1
Cable description
• Tight Buffered Fibre
• Aramid
• Outer Jacket
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
Applications
• Indoor
• Pigtail and jumper connections
• Direct connection to terminal equipments FTTx
Drop cable
SPECIFICATIONS
Type
Advantages
• Flexible / Dielectric / Direct connectorization.
S105
S110
S115
1
2
1
2
0,9
0,6
0,9
0,9
Fibre Count
Buffer Diameter (mm)
Typ
Fib
Buf
G.657 A
Fib
Aramid Yarns
Str
Outer Jacket
LSZH2
Inn
Jacket Colour
Ivory
Fibre Type
Strength Members
7
Weight (Kg/Km)
ø Outer (mm)
Tensile Load Permanent / Instal. (N)
Options
• Fibre type
• Special colour code
• Jacket colour
• Special packaging “Reel in a Box” 1
SP
S100
Crush (N/100mm)
Temperature Range
Min. Bending Radius (mm)
2.9
± 0.15
Ou
7
2.9
14
± 0.15
3.6
± 0.15
14
3.6
± 0.15
Jac
We
200 / 350
200 / 350
200 / 350
200 / 350
øO
500
500
700
700
Ten
-10ºC to + 70ºC
Cru
5 x ø Outer
Tem
Standards
Environmental and mechanical tests according to EN187000 and IEC60794.
Fire tests : UNE-EN 50265 (IEC 60332-1) / UNE-EN 50267 (IEC 60754-1/2) / UNE-EN 61034 (IEC 61034-1/2).
Fibres colour code : 1 FO: Natural / 2 FO: Red – Green.
1
Consult available lengths.
2
LSZH – Halogen free, low smoke emission, flame retardant compound.
Min
01. Tight Buffered Fibre
02. Aramid
03. Outer Jacket
Indoor
CAS FLAT - F1
Cable description
• Fibre Optics
• FRP
• Outer Jacket
Fire Resistance
• Halogen free
• Flame retardant
• Low smoke emission
Drop cable
SPECIFICATIONS
SP
F100
Ty
Fibre count
2
Fib
Fibre Type
G.657 A
Type
Identification
Strength Members
Colour Code
St
FRP
Ou
1
Applications
• Indoor
• FTTx
Outer Jacket
LSZH
Ja
Jacket Colour
Ivory
We
7.6
øO
Advantages
• Lightweight / Resistant / Totally dielectric / Reduced diameter
ø Outer (mm)
2.0 x 3.0 ± 0.20
Ten
Ins
Weight (Kg/Km)
Max. Tensile Load
100
Crush
1000 N / 10 cm
Temperature Range
-30º C to +70ºC
Standards
Environmental and mechanical tests according to EN 187000 and IEC 60794.
Fibres colour code: Red – Green.
1
LSZH: Halogen free, low smoke, flame retardant compound.
01. Fibre Optics
02. FRP
03. Outer Jacket
Fib
1
Cr
Te
Mi
50
/2).
SPECIFICATIONS
R100
Type
Fibre Count
Buffer Diameter (mm)
R105
1
2
0.9
0.6
Aramid Yarns
Strength Members
Inner Jacket
LSZH2
Outer Jacket
LSZH2
Jacket Colour
Ivory
Applications
• Indoor
• Drop cable
• Pigtail and jumper connections
• Direct connection to terminal equipments FTTx
21
Weight (Kg/Km)
4.6 ±0.2
ø Outer (mm)
350 / 650
Tensile Load Permanent / Instal. (N)
Options
• Fibre type
• Special colour code
• Jacket colour
• Special packaging “Reel in a Box” 1
800
Crush (N/100mm)
-10ºC to +70ºC
Temperature Range
5 x ø Outer
Min. Bending Radius (mm)
CAR / R1
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
G.657A
Fibre Type
Cable description
• Tight Buffered Fibre
• Aramid
• Inner Jacket
• Aramid
• Outer Jacket
Indoor
Reinforced drop cable
Standards
Mechanical and environmental tests according to EN187000, IEC60794.
Fire tests : UNE-EN 50265 (IEC 60332-1) / UNE-EN 50267-1/2 (IEC60754-1/2) / UNE-EN 61034-1/2 (IEC
61034-1/2).
Fibres colour code : 1 FO: Natural / 2 FO: Red – Green.
1
Consult available lengths.
2
LSZH – Halogen free, low smoke emission, flame retardant compound.
Advantages
• Flexible / Resilient / Dielectric / Reinforced / Direct connectorization.
01. Tight Buffered Fibre
02. Aramid
03. Inner Jacket
04. Aramid
05. Outer Jacket
CDV / V1
Distribution cable
Cable description
• Tight Buffered Fibre (0.9 mm)
• Aramid Yarns
• Outer Jacket
SPECIFICATIONS
V100
Type
Fibre Count
2
4
6
8
Aramid Yarns
Strength Members
Outer Jacket
Thermoplastic LSZH2
Jacket Colour
Ivory
Weight (Kg/Km)
ø Outer (mm)
Tensile Load Permanent /
Instal. (N)
Crush (N/100mm)
Temperature Range
Min. Bending Radius (mm)
12
G.657A
Fibre Type
23
4.9
±0.3
26
5.3
±0.3
400 / 650
400 / 650
1000
1000
36
6.1
±0.3
43
6.7
±0.3
56
7.7 ±0.3
400 / 650 550 / 1000 550 / 1000
1000
1200
1200
-10º C to +70ºC
5 x ø Outer
Standards
Mechanical and environmental tests acc/ EN 187000, IEC60794.
Fire tests: UNE-EN 50266 (IEC 60332-3) / UNE-EN 50267 (IEC 60754-2-1/-2) / UNE-EN 61034 (IEC 610342-1/-2).
Fibres colour code: red – green – grey – yellow – blue – natural – white – brown – violet – orange – pink – black.
1
Consult available lengths.
2
LSZH – Halogen free, low smoke and flame retardant thermoplastic compound.
Fire Resistance
• Flame / Fire retardant
• Halogen free
• Low smoke emission
Indoor
5
p. 21
Applications
• Indoor
• Drop cable (vertical)
• Direct connectorizations in FTTx applications
Options
• Fibre type
• Special colour code
• Outer jacket colour
• Special packaging “Reel in a Box” 1
03
Advantages
• Compact / Lightweight / Flexible / Easy to strip (gel free) / Totally dielectric
/ Direct connectorization / Saves installation costs.
01
02
01. Tight Buffered Fibre
02. Aramid Yarns
03. Outer Jacket
p. 22
Outdoor
CAR - R2
Cable description
• Tight Buffered Fibre
• Aramid
• Outer Jacket
Applications
• Outdoor
• Self-supported drop cable FTTx
Aerial cable
SPECIFICATIONS
Type
Fibre Count
Buffer Diameter (mm)
R205
Fib
1
2
St
0.9
0.6
Ou
Ja
Aramid Yarns
We
Outer Jacket
LSZH1
øO
Jacket Colour
Black
Te
Weight (Kg/Km)
Advantages
• Excellent mechanical resistance / Dielectric / Tough / Resistant.
R200
G.657A
Fibre Type
Self-supporting Element
Options
• Fibre type
• Outer jacket colour
SP
13
ø Outer (mm)
2.5 x 5.2
Tensile Load Permanent / Instal. (N)
250 / 400
Crush (N/100mm)
Impact (Nm/100 impacts)
Temperature Range
Te
Mi
(m
600
1.5
-20ºC to +80ºC
Standards
Mechanical and environmental tests according to EN187000, IEC60794.
Fire tests : UNE-EN 50265 (IEC 60332-1) / UNE-EN 50267-1/2 (IEC60754-1/2) / UNE-EN 61034-1/2 (IEC
61034-1/2).
Fibres colour code : 1 FO: Natural / 2 FO: Red – Green.
1
LSZH: Halogen free, low smoke emission, flame retardant compound.
01. Tight Buffered Fibre
02. Aramid
03. Outer Jacket
Outdoor
ADSS FLAT - F2
Cable description
• Fibre Optics
• FRP
• Outer Jacket
Self-supported cable
SPECIFICATIONS
Type
Fibre Count
Applications
• Outdoor
• Self-supported drop cable FTTx
Fibre Type
F200
Fib
Up to 12
Tot
G652D / G657A
Ou
Co
Outer Jacket
Black PE
We
Weight (Kg/Km)
31 Kg/Km
ØO
Ø Outer
Max. Tensile Load
3.8 mm x 7.0 mm ± 0.20
1200 N
Min. Bend Radius Static /
Dinamic
20 x Ø Outer / 30 x Ø Outer
Temperature Range Operation / Installation
-40ºC to + 70ºC
Standards
Mechanical and environmental tests according to EN187000, IEC60794-1-2.
Fibres colour code: Red – Green – Blue – Yellow – Grey – Violet – Brown – Orange – White – Pink – Black – Natural.
01. Fibre Optics
02. FRP
03. Outer Jacket
Fib
FRP
Strength Members
1
Ac
Colour Code1
Fibres Identification
Advantages
• Excellent mechanical resistance / Dielectric / Tough / Resistant / Aerial drop applications.
SP
Ten
Tem
Mi
p. 23
Cable description
• Fibre Optics
• Secondary Loose Tube
• Aramid
• Outer Jacket
SPECIFICATIONS
2 .. 12
Fibre Count
Aramid Yarns
Strength Members
Outer Jacket
Thermoplastic LSZH1
Jacket Colour
Black
Fire Resistance
• Flame retardant
• Halogen free
• Low smoke emission
10
Weight (Kg/Km)
3.5 ± 0.1
ø Outer (mm)
Applications
• Indoor
80
Tensile Load (N)
ABD - 01
Indoor
Loose tube cables
Temperature Range
-30 ºC to +70 ºC
Min. Bending Radius
(mm)
20 x ø Outer
Advantages
• Compact / Tough / Resistant / Totally Dielectric / Suitable for “blow air” systems.
Standards
Environmental and Mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black, natural.
01. Fibre Optics
02. Secondary Loose Tube
03. Aramid
04. Outer Jacket
ABD
SPECIFICATIONS
Fibre Count
Total Tubes
Active Tubes
24
6
2
36
6
3
Fibres per Tube
Outer Jacket
Colour
Weight (Kg/Km)
Ø Outer (mm)
Tensile Load (N)
Temperature Range
Min. Bending radius
29
5.7 ± 0.2
500
29
5.7 ± 0.2
500
48
6
4
72
6
6
12
Polyethylene
Black
29
29
5.7 ± 0.2
5.7 ± 0.2
500
500
-40 ºC to +70 ºC
20 x ø Outer
96
8
8
144
12
12
Cable description
• Central Element (GRP)
• Fibre Optics
• Loose Tubes (Jelly Filled)
• Outer Jacket
Applications
• Outdoor
42
6.6 ± 0.2
1200
72
8.6 ± 0.2
1500
Outdoor
Loose tube cables
Options
• LSZH Jacket
• PA12 Jacket
Advantages
• Compact / Tough / Resistant / Totally Dielectric / Excellent resistance to friction / Suitable for “blow air” systems.
04
03
Standards
Environmental and Mechanical tests according to EN 187000 and CEI 60794.
Fibres colour code: red, green, blue, yellow, grey, violet, brown, orange, white, pink, black, natural.
02
01
01. Central Element (GRP)
02. Fibre Optics
03. Loose Tubes (Jelly Filled)
04. Outer Jacket
p. 24
Subscriber connection point
01.Base
02.Top
SCP
Modularity
• Support joint (till 4 units)
• Cable access punching
• Rear access cable
• Slide
Applications
• Into the buildings
• Subscriber Cable (CAS, CAR, CDV)
• Direct Connectorization in FTTx applications
Subscriber
connection point
Options
• From 1 to 4 SC/APC adaptors
• Supplied with Pre-assembled Cable
Benefits
• Compact and Small format.
• Lightweight
• Easy installation
• Modern design
• Installation cost savings
Dimensiones
mm
A
Large
130
B
Width
75
C
Height
37
D
Height
18
D
A
B
C
Kit FTTx Line
It will be possible to supply this termination box
in 25, 40 or 50 m. with pre-assembled cable
in SC/APC adaptors, from 1 to 4 plugs. This
means a reduction in time and cost during the
installation.
Kit estandard
1 o 2 Pig-tail FO SM G657 – SC/APC
+
1 o 2 Adaptors – SC/APC
+
1 o 2 Mechanical splices
+
1 o 2 Mechanical splices
+
Termination box
p. 25
Cable BOX
Reel in a box:
• Plastic structure
• Spool
• Carton box
Applications
• Into the buildings
• Subscriber cable (CAS, CAR,…)
• Internal Distribution cable (CDV)
Options
• Subscriber cable: 305 / 500 / 1.000 m
• Internal Distribution cable: 150 / 200 / 250 m
Benefits
• Lineal unwinding / Compact / Lightweight/ Easy installation / Installation costs savings
A
C
B
Dimensions
A
Height
350 mm
B
Width
350 mm
C
Depth
350 mm
Characteristics
CABLE TYPE
ø mm
Box 305
Box 500
Box 1000
CAS (S100, S105)
2,9 ± 0,15
4 kg
5,5 kg
9 kg
CAS (S100, S105)
3,6 ± 0,2
6 kg
9 kg
16 kg
CAS-FLAT (F100)
2×3 ± 0,2
4 kg
6 kg
9,5 kg
CAR (R100, R105)
4,6 ± 0,2
9,5 kg
14,5 kg
CAR (R200, R205)
2,5×5,2 ± 0,2
6 kg
8,5 kg
CABLE TYPE
ø mm
Box 150
Box 200
Box 250
CDV (V100) 4
5,5 ± 0,3
8 kg
9 kg
CDV (V100) 6
6,2 ± 0,3
8 kg
9,5 kg
11,5 kg
CDV (V100) 8
6,9 ± 0,3
9 kg
11 kg
13,5 kg
CDV (V100) 12
7,9 ± 0,3
11 kg
14 kg
Characteristics
03
01
01. Plastic structure
02. Spool
03. Carton box
02
p. 26
5
4
3
1
Solution
FTTx
2
p. 27
5
5
4
1
1
TRUNK Cable (1): Could be used to any type of cable depending on the environment:
Conventional method: Blow microducts: Aerial installation:
PKP, PSP, DP, DSP, NEXO o TENAX
ABD o HD
ADSS, …
DROP Cable: Could be applying any type of cable (usually till 24fo), it has his origin point in a trunk cable and his
destination in the building or cabinet in the curb (usually in the distribution boxes):
Outdoor installation (2): Indoor installation (3): Subscriber installation (4): Subscriber connection point (5): CAR R200, ADSS F200, ABD-01, …
CAR R100, CAR R105 o CDV (+ 2 viviendas)
CAS S100 – S115 (bajo tubo)
CAS FLAT (bajo tubo o pared)
CAR R100 o R105 (bajo tubo o pared)
Roseta PCU
p. 28
Optical Comunications
MULTIMODE OPTICAL FIBRE 62,5 / 125
Graded-Index multimode optical fibres 62,5/125 micron. The fibres are designed for its use at the wavelengths of 850 nm and 1300 nm.
These fibres are suitable for use in premises wiring applications, like Local Area Networks (LAN) with video, data and voice using LED,
VCSEL or Laser Fabry Perot sources. These fibres comply with IEC 60793-2-10 A1b.
Geometrical and mechanical
characteristics
Values
Attenuation Coefficient
(db/Km)
62.5 ± 2.5 μm
Core diameter
≤ 6%
Core non-circularity
Bandwidth
(MHz x Km)
≤ 1.5 µm
Core / Cladding concentricity error
125+/-2 µm
Cladding diameter
Link Distance (m)
≤ 1%
Cladding non-circularity
245+/-10 µm
Primary coating diameter
Group Index of
Refraction
≤ 12.5 µm
Coating concentricity error
850 nm
OM1
OM2
Giga
≤ 3.0
≤ 3.0
≤ 3.0
1300 nm
≤ 0.7
≤ 0.7
≤ 0.7
850 nm
≥ 200
≥ 500
≥ 200
1300 nm
≥ 500
≥ 500
≥ 500
1000Base-SX
275
550
500
1000Base-LX
550
550
1000
0.275 ± 0.015
Numerical Aperture
≤ 6%
Coating non-circularity
Proof Test
Optical characteristics
850 nm
1496
1300 nm
1491
≥ 8.8 N / ≥ 1 % / ≥ 100 Kpsi
Optical properties according to IEC 60793-2-10, ISO/IEC 11801, EN 50173, ANSI/TIA/EIA-492AAAA-A and ANSI/EIA/TIA 568-C.
Geometrical and mechanical characteristics according to IEC 60793-2-10.
Optical Comunications
MULTIMODE OPTICAL FIBRE 50 / 125
Geometrical and mechanical characteristics
Graded-Index multimode optical fibres 50/125
micron. The fibres are designed for use at 850 and
1300 nm. These fibres are suitable for use in
premises wiring applications, like Local Area Networks (LAN) with video, data and voice using LED,
VCSEL or Laser Fabry Perot sources.
These fibres comply or exceed the standards
IEC 60793-2-10 A1a.1, A1a.2, A1a.3, TIA/
EIA-492AAAB, TIA/EIA-492AAAC-A, TIA/EIA492AAAD, Telcordia GR-20-CORE, GR-409-CORE,
TIA/EIA 568C.
Values
50 ± 2.0 μm
Core diameter
Core non-circularity
≤5%
Core / Cladding concentricity error
≤ 1 μm
125 ± 1.0 μm
Cladding diameter
≤ 0.7 %
Cladding non-circularity
242 ± 5 μm
Primary coating diameter
≤5%
Coating non-circularity
≤ 12.5 μm
Coating concentricity error
≥ 8.8 N / ≥ 1 % / ≥ 100 Kpsi
Proof Test
Geometrical and mechanical characteristics according to IEC 60793-2-10.
Optical characteristics
Attenuation Coefficient (db/Km)
Bandwidth
(MHz x Km)
Link Distance (m)
850 nm
OM2
OM2 XL
OM3 SL
OM3
OM4
Giga
≤ 2.5
≤ 2.5
≤ 2.5
≤ 2.5
≤ 2.5
≤ 2.5
≤ 2.5
1300 nm
≤ 0.7
≤ 0.7
≤ 0.7
≤ 0.7
≤ 0.7
≤ 0.7
≤ 0.7
850 nm
≥ 200
≥ 500
≥ 600
≥ 700
≥ 1500
≥ 3500
≥ 600
1300 nm
≥ 500
≥ 500
≥ 1200
≥ 500
≥ 500
≥ 500
≥ 1200
1000Base - SX
275
550
550
800
900
1100
750
1000Base - LX
550
550
550
550
550
550
2000
1000Base - SX
33
82
82
150
300
550
110
0.200 ± 0.015
Numerical Aperture
Group Index of Refraction
OM1
850 nm
1.482
1300 nm
1.477
Optical properties according to IEC 60793-2, ISO/IEC 11801, EN 50173, TIA/EIA-492AAAB, TIA/EIA-492AAAC-A, TIA/EIA-492AAAD, Telcordia GR-20-CORE, GR-409-CORE, TIA/EIA 568C.
68-C.
p. 29
Optical Comunications
SINGLEMODE OPTICAL FIBRE SMF G.652B / G.652D / G.655
Step index singlemode optical fibres. G652
fibres provide optimum performance in the
1310 nm wavelength. They can be used on
metropolitan and access networks, CATV and
premises applications in telecom.
These fibres comply or exceed the standards
IEC 60793-2-50, ITU-T G.652.B, G.652.D,
Telcordia GR-20-CORE, ANSI/ICEA S-87640, RUS 7CFR 1755.900, ANSI/TIA/EIA492CAAA.
Geometrical and mechanical
characteristics
G.652.B
Cladding Diameter
Core / Cladding Concentricity
Cladding Non-Circularity
Primary Coating Diameter
Coating / Cladding Concentricity
Coating Non-Circularity
Proof Test
125 ± 0.7 μm
125 ± 1 μm
≤ 0.5 μm
≤ 0.6 μm
≤ 0.7 %
≤ 1.0 %
242 ± 7 μm
≤ 12 μm
≤7%
≤5%
≥ 8.8 N / ≥ 1 % / ≥ 100 Kpsi
G.652 D
G.655
G.652.B
1310 nm
1550 nm
1310 nm
1383 nm
1460 nm
1550 nm
1625 nm
1310 nm
1530 - 1565 nm
1285 - 1330 nm
1565 - 1625 nm
1550 nm
1625 nm
Attenuation Coefficient
(dB / Km)
Chomatic Dispersion Coefficient
(ps / nm.Km)
9.0 ± 0.4
10.1 ± 0.5
≤ 0,35
≤ 1,0
----≤ 0,23
≤ 0,24
--------≤3
----≤ 18
≤ 22
1300 -1322
≤ 0,092
1467
1468
≤ 1260
≤ 0,1
Zero Dispersion Wavelength (nm)
Zero Dispersion Slope (ps / nm2 Km)
1310 nm
1550 nm
Cabling
1550 nm
Group Index of Refraction
Cable Cutt-Off Wavelength (nm)
PMD (ps / √Km)
G.655
125 ± 1.0 μm
≤ 0.6 μm
≤ 1.0 %
Optical characteristics
Mode Field Diameter
(µm)
G.652.D
9.0 ± 0.4
10.1 ± 0.5
≤ 0,35
≤ 0,35
≤ 0,25
≤ 0,22
≤ 0,23
--------≤3
----≤ 18
≤ 22
1300 -1322
≤ 0,090
1467
1468
≤ 1260
≤ 0,1
----9.2 ± 0.5
≤ 0,40
≤ 1,00
----≤ 0,25
≤ 0,28
-6
5.5 to 10
-10 to -3
7.5 to 13.8
8
12
≤ 1440
≤ 0,052
1.4682
1.4683
≤ 1300
≤ 0,2
Characteristics according to ITU-T G.652, IEC 60793-2-50, ISO/IEC 11801, EN 50173, Telcordia GR-20-CORE, ANSI/ICEAS-87-640, RUS 7CFR 1755.900, ANSI/TIA/EIA-492CAAA.
SINGLEMODE OPTICAL FIBRE SMF - G.657
Low macrobending sensitive fibre (G657)
provides high resistance to additional
losses due to macrobending. Ideal for cable
mounting inside buildings, patchcords and/
or interconnection cables. It offers significant
added value in Fibre-to-the-Home accesss
networks.
The fibre fully comply with or exceeds the IEC 60793-2-50,
ITU G.652.D, G.657.A&B, Telcordia GR-20-CORE, ANSI/
IECA S-87-640.
Geometrical and mechanical
characteristics
Cladding Diameter
Core / Cladding Concentricity
Cladding Non-Circularity
Primary Coating Diameter
Coating / Cladding Concentricity
Coating Non-Circularity
Proof Test
Optical characteristics
Attenuation with Bending
(1550 nm)
Mode Field Diameter
(μm)
Attenuation Coefficient
(dB/Km)
Chomatic Dispersion Coefficient
(ps/nm.Km)
Zero Dispersion Wavelength (nm)
Zero Dispersion Slope
(ps / nm2 Km)
Cable Cutt-Off Wavelength (nm)
PMD (ps / (ps/√Km)
G.657.A
1 turn / Mandrel 10mm
10 turns / Mandrel 15mm
1310 nm
1550 nm
1310 nm
1383 nm
1460 nm
1550 nm
1625 nm
1285 – 1330 nm
1550 nm
1625 nm
≤ 12 μm
G.657.B
125 ± 0.7 μm
≤ 0.5 μm
≤ 0.7 %
242 ± 0.7 μm
≤ 10 μm
≤5%
≥ 8.8 N / ≥ 1 % / ≥ 100 Kpsi
G.657.A
G.657.B
≤ 0.75
≤ 0.25
9.0 ± 0.4
10.1 ± 0.5
≤ 0.10
≤ 0.03
8.5 – 9.3
9.4 – 10.4
1300 – 1322
≤ 0.090
1550 nm
Characteristics according to ITU-T G.652.D, G.657A, G.657B, IEC 60793-2-50, Telcordia GR-20-CORE and ANSI/ICEA S-87-640.
Important notice
At present, G657 fibres are not recognized by some splicing machines. Check your machine before use it or ask your local distributor.
≤ 0.35
≤ 0.35
≤ 0.25
≤ 0.21
≤ 0.23
≤ |3|
≤ 18
≤ 22
≤ 1260
≤ 0.1
1300 – 1324
≤ 0.092
p. 30
VM1 - VIDEO
Optoelectronic converters
Multimode fibre
The OPTRAL Series VM1 allows the transmission of one standard
video signal over multimode optical fibre. One transmitter and one
receiver using one single fibre form the basic system. The receivers
in modular and rack format are available with Automatic Gain
Control (AGC) and do not require any kind of adjustments
(Models: VM107). All the models comply with the requirements
according to the Electromagnetic Compatibility and Low
Tension Standards ( Marking).
Specifications
Features
• Multimode optical fibre
• Wavelength 850nm and 1300 nm
• Modular Units: Type S, Type M, Mini, Micro and rack cards
• Configurable for short and long distances
• Optical connectors: ST(1)
Power / temperature / size
• Temperature = 0º ÷ +50ºC
• Humidity = 10% ÷ 90%
• 12 Vdc / 250 mA
• Modular Units:
- Type S = 105 x 95 x 32 mm
- Type M = 179 x 127 x 32 mm
- Type Mini = 67 x 47 x 25 mm
- Type Micro = 61 x 25 x 23 mm
Video signal
• I/O Impedance = 75 Ω
• Bandwidth = 10 MHz
• Differential Gain< 2%
• Differential Phase< 2º
• I/O Video connector = BNC
• AGC Included in the receivers
(Models: VM107)
Accesories (not included)
• Modular Units (Power Supplies)
- Type S, M, Mini and Micro = PS150
• Rack Cards
- Card Cage 3U (Rack 19”) = PR100
(1) For other optical connectors, consult us.
Available models
Reference
Description
Format
Nº Fibres
VM101-TB1
1 Tx Vídeo Modular
Type S
1
VM101-TR1
2 Tx Vídeo Rack
Rack
2
VM102-TB1
2 Tx Vídeo Modular
Type M
2
VM101-RB1
1 Rx Vídeo Modular
Type S
1
VM101-RR1
2 Rx Vídeo Rack
Rack
2
VM101-TB2
1 Tx Vídeo Modular
Type S
1
VM101-TR2
2 Tx Vídeo Rack
Rack
2
VM102-TB2
2 Tx Vídeo Modular
Type M
2
VM101-RB2
1 Rx Vídeo Modular
Type S
1
VM101-RR2
2 Rx Vídeo Rack
Rack
2
VM104-TB1
1 Tx Vídeo Mini
Mini
VM104-TB2
1 Tx Vídeo Mini
Mini
VM105-TB1
1 Tx Vídeo Micro
VM105-TB2
1 Tx Vídeo Micro
Maximum
attenuation (3)
Wavelength
14 dB
850 nm
14 dB
1300 nm
1
12 dB
850 nm
1
12 dB
1300 nm
Micro
1
12 dB
850 nm
Micro
1
12 dB
1300 nm
(3) Maximum attenuation at 62.5/125. For 50/125 reduce optical budget by 3dB.
Type S = 105 x 95 x 32 mm / Type M = 179 x 127 x 32 mm / Type Mini = 67 x 47 x 25 mm / Type Micro = 61 x 25 x 23 mm
Other equipments
VM7 - Video + RS-232
Accessories
OM1-Contacts ON/OFF
MCM - MCS - Ethernet
mm
p. 31
DM5 - DATA
RS232, RS422 and RS485
Features
• Multimode Optical Fibre
• Wavelength 850 nm and 1300 nm
• Modular Units, Rack Cards and DIN rail
• Configurable for short and long distances
• Optical connectors: ST (1)
(1)For other optical connectors consult us
Optoelectronic converters
Multimode fibre
The OPTRAL Series DM5 allows the transmission and reception of RS232, RS422 andRS485 data signals over
multimode optical fibre. The basic system consists of twotransceiver and two fibre optics for each communication
channel with speeds up to 115 Kbs.The communication protocol: RS232, RS422, RS485-2H (2 Wires Half
Duplex) and RS4854H (4 Wires Full Duplex), can be selected by a switch.
Power / temperature / size
• Temperature = 0º ÷ +50ºC
• Humidity = 10% ÷ 90%
• Power:
- 12 Vdc / 250 mA for Rack Cards
- 12 to 24Vdc for Modular Units and DIN
• Size
- DIN rail = 45 x 70 x 121 mm
- Type S = 105 x 95 x 32 mm
- Type Rack = 1 Slot Rack
Communication
• Data rate ≤ 115 Kbs
• Bit Error Rate ≤ 10-9
• Operating mode = Asynchronous / Half - Full Duplex
• Selection of communication: SWITCH
• Data connector = Screw Terminal CI (7 pin)
Accesories (not included)
• Modular Units (Power Supplies)
- Type S = Model PS150
- DIN rail = Model PS150
• Rack Cards
- Card Cage 3U (Rack 19”) = PR100
All the models comply with the requirements according to the Electromagnetic Compatibility and Low Tension
Standards (
Marking).
Specifications
Reference
DM501-XD1
DM501-XB1
DM501-XR1
DM501-XD2
DM501-XB2
DM501-XR2
Available models
Description
Transceiver
RS232, RS422
and RS485
Transceiver
RS232, RS422
and RS485
Transceiver
RS232, RS422
and RS485
Transceiver
RS232, RS422
and RS485
Transceiver
RS232, RS422
and RS485
Transceiver
RS232, RS422
and RS485
Format
Nº Fibres
Maximum
attenuation (2)
Wavelength
DIN rail
2
14 dB
850 nm
Type S
2
14 dB
850 nm
Rack
2
14 dB
850 nm
DIN rail
2
14 dB
1300 nm
Type S
2
14 dB
1300 nm
Rack
2
14 dB
1300 nm
(2) Maximum attenuation at 62.5/125. For 50/125 reduce optical budget by 3dB.
DIN rail = 45 x 70 x 121 mm / Type S = 105 x 95 x 32 mm
Factory and offices:
Poligono Industrial Ctra. BV-5128 Km-22
08359 Sant Iscle de Vallalta (Barcelona) -SpainTel. ++34 93 741 86 86
Fax. ++34 93 741 86 99
e-mail: optral@optral.com
Web: www.optral.com
Madrid delegation:
Avenida Valdelaparra 3 Edificio oficinas:
1ª Planta - Oficina 5
28108 Alcobendas ( Madrid ) -SpainTelf. Comercial: ++34 91 345 08 49
Telf. Administración: ++34 93 741 86 86
Fax. ++34 91 359 45 09
e-mail: madrid@optral.es
Web: www.optral.com
OPTRAL Chile:
Diego de Velásquez 2071 of. 1906
Providencia - Santiago - Chile
Fono: +56-2-7106794
Fax: +56-2-7387538
Cel: 56-9-0995002
e-mail: mvinay@optral.cl
Web: www.optral.com
Download