Operating Instructions Excellence Plus Balances XP Models – Part 3 Contents 3 Contents 1 Introduction to Adjustments and Tests............................................................................................................ 4 1.1 1.2 1.3 1.4 1.5 Important to know.................................................................................................................................................... 4 Basic principles for settings and tests....................................................................................................................... 4 GWPExcellence™.................................................................................................................................................... 4 The Configuration Process........................................................................................................................................ 5 Satisfying Documentation Requirements................................................................................................................... 5 2 Accessing the Adjustments and Tests............................................................................................................ 6 2.1 Overview: Settings for adjustments and tests............................................................................................................. 7 3 Settings for Adjustments and Tests............................................................................................................... 8 3.1 3.1.1 3.2 3.2.1 3.2.2 3.2.3 3.2.3.1 3.2.3.2 3.2.3.3 3.2.3.4 3.2.3.5 3.2.3.6 3.2.3.7 3.2.3.8 3.2.3.9 3.3 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.4 3.4.1 3.5 3.6 3.7 3.8 Weights................................................................................................................................................................... 8 Weight Parameters.................................................................................................................................................. 8 Test Sequences..................................................................................................................................................... 10 Test Sequence Parameters..................................................................................................................................... 11 Settings of the Parameter “Action if Failure” = Warning............................................................................................. 13 The Method........................................................................................................................................................... 15 Defining Weights and Tolerances for a Method........................................................................................................ 15 EC Method for Eccentricity Test............................................................................................................................... 17 RP1 Method for Repeatability Test........................................................................................................................... 18 RPT1 Method for Repeatability Test with Tare............................................................................................................ 19 SE1 Method for Sensitivity Test with 1 Testpoint........................................................................................................ 20 SE2 Method for Sensitivity Test with 2 Testpoints...................................................................................................... 21 SERVICE Method for Reminder / Early Notification.................................................................................................... 22 SET1 Method for Sensitivity Test with Tare and 1 Testpoint......................................................................................... 24 SET2 Method for Sensitivity Test with Tare and 2 Testpoints....................................................................................... 25 Tasks..................................................................................................................................................................... 26 Task State.............................................................................................................................................................. 27 Assigning a Test Sequence to the Task..................................................................................................................... 27 Starting Method..................................................................................................................................................... 28 Defined Days......................................................................................................................................................... 29 Defined Users........................................................................................................................................................ 30 ProFACT / int. Adj.................................................................................................................................................... 31 Advanced Options.................................................................................................................................................. 32 Automatic Adjustment Using an External Test Weight................................................................................................ 33 Automatic Adjustment Testing Using an External Test Weight..................................................................................... 34 Test History............................................................................................................................................................ 35 Protocol – defining the Adjustment and Test Reports................................................................................................ 36 4 Glossary - GWP Functions................................................................................................................................. 38 5 Index....................................................................................................................................................... 40 Introduction to Adjustments and Tests 4 1 Introduction to Adjustments and Tests These Operating Instructions relate to configuring your XP Balance ready to perform adjustments and tests. Warning: It is essential that you have read the Operating Instructions – Part 1 and Part 2 for the XP balances (separate document). You must also have read the Safety Instructions in Part 1 and assembled and installed the balance according to the operating instructions. The balance must be leveled. 1.1 Important to know The default settings in these Operating Instructions are marked with the symbol 8 after the name of the setting. Example: Standard 8 Where applicable, the Factory Setting has been specified. To print out the settings or the report a printer must be connected and activated as the output device in the peripheral settings. 1.2 Basic principles for settings and tests Balances play a very important role in research, development, quality assurance and production. Errors in weight measurements cost time and money and violations to legal requirements may even cause damage to health. With the Good Weighing Practice™ from METTLER TOLEDO, the routine testing of your balance is made efficient, accurate and secure. Our GWPBase™ service provides you with a unique personalized document containing precise recommendations for the routine testing of your balances according to your weighing risk with regards to: • How to test your balance and when (how often) • Which weights should be used • What tolerances are appropriate You can find more information on our website: www.mt.com/GWPBase GWPExcellence™ is the part of the balance firmware which has been specially developed to simplify routine testing procedures. In combination with GWPBase™ you can ensure efficient balance testing to meet your audit requirements. 1.3 GWPExcellence™ GWPExcellence™ is a collection of embedded safety functions for XS/XP Balances.These individually programmable functions simplify routine testing procedures and hence improve the measurement accuracy of your balance. Many of these functions relate to the routine testing of your balance with external test weights and actively support you with requests for a test to be performed at a pre-defined time. Step-by-step user guidance provided on the balance display allows complex procedures, such as a repeatability test, to be performed without error by anyone in the laboratory. In conjunction with internal sensors, further functions have been developed to avoid measurement error; e.g. temperature sensors can trigger an internal adjustment when the temperature changes more than a pre-defined amount. In order to ensure that tests are executed as desired and that reports are generated correctly, it is necessary for you to define and maintain all relevant criteria for your tests. Making a record of your tests and adjustments to meet documentation requirements can be easily done by connecting the balance to a printer or PC as desired. Introduction to Adjustments and Tests 5 1.4 The Configuration Process To prepare your balance for performing routine tests and adjustments is a straightforward three step process: 1. Register your Weights: The information relating to each of your test weights is entered and stored in a weights database. 2. Define the Test Sequence: The Test Sequence describes the type of test (method) to be done and which test weight and tolerance to use. 3. Create the Task: The task defines when and how the test sequence should be started and executed. Section 3 describes all the settings in detail. 1.5 Satisfying Documentation Requirements To maintain full traceability of your adjustments and tests it is important that you periodically print out your settings and your results from the Test History. Your results are stored in the test history with a maximum of 120 records. When the limit is reached the oldest results are deleted. Each time you modify a test sequence the version number is incremented and displayed in the top right hand corner of the balance display. It is recommended that each new version should be printed as a record for your log book. A complete list of individual settings can be printed out by pressing the «F» key while the relevant menu is open. To print out settings and reports a printer must be connected and activated as the output device in the peripheral settings. Accessing the Adjustments and Tests 6 2 Accessing the Adjustments and Tests Access the system settings by either selecting the application menu using the «D» key or the menu for the user settings using the «C» key, and then press the “System” button. The system settings are represented by icons. The individual settings can be called up and changed by touching the icons. The system settings apply to the entire weighing system and therefore to all user profiles and applications. D C The following system settings are available. “Adjust/Test” Set parameters for adjustments and tests (see section 3 of this document). Detailed instructions to the system settings “Balance Info”“Standby”,“Date/Time”,“Peripherals”,“Administrator” and “Levelcontrol” can be found in the Operating Instructions – Part 2 for XP balances. To return to the active application press the “Exit” button. Press the Adjust/Test icon to access the adjustments and tests menu. The following section presents an overview of all the different settings available. Section 3 describes the settings in detail. Accessing the Adjustments and Tests 7 2.1 Overview: Settings for adjustments and tests Test/Adj. Weights Test/Adj. Weight 01 List of 12 Test/Adj. Weights (section 3.1.1) Method Parameters of one Test/Adj. Weight (section 3.1.1) OK Parameters of the selected Method (section 3.2.3) OK OK Test Sequences Test Sequence List of 12 Test Sequences (section 3.2.1) Parameters of one Test Sequence (section 3.2.1) OK Adjust/Test Action if Failure OK Parameters of the selected Action if Failure (section 3.2.2) Setup Test/Adj. Weights Define Test Sequences Define Tasks Define ProFACT / int. Adj. On Autom. ext.Adjust Off Autom. ext.Test Off OK Tasks Task State List of 12 Tasks (section 3.3) Task State of one Task (section 3.3.1) OK OK Parameters of one Task (section 3.3.2) OK ProFACT Test History Define Protocol Define ProFACT Status of ProFACT / int. Adj. (section 3.4) OK Parameters of ProFACT / int. Adj. (section 3.4) OK OK ProFACT / int. Adj. Parameters of ProFACT Advanced (section 3.4.1) OK Adjustment and test protocol selection Autom. ext. Adjust. Autom. ext Adjust. Status of Adjust Weights (section 3.5) List of Printout Options (section 3.8) OK OK Test History Adj. History List of Histories (section 3.7) Parameters of Autom. Ext. Adjust Weight (section 3.5) Autom. ext. Test Adjust History (section 3.7) OK OK Autom. ext. Test Status of Autom. ext. Test (section 3.6) OK Parameters of Autom. ext. Test. (section 3.6) OK Adj. History Selection GWP History Adj. History Selection (section 3.7) GWP History (section 3.7) OK OK OK Settings for Adjustment and Tests 8 3 Settings for Adjustments and Tests This section describes all the menu options available for defining the parameters relating to the adjustment and testing of your balance. 3.1 Weights When “Test/Adj. Weights” is selected you are provided with a list of weights. Up to 12 external test weights can be configured. Select an undefined weight to be configured or the name of the weight whose parameters you wish to update. These test weights are used for performing the external tests and adjustments and the appropriate one will be selected when defining the Test Sequences. Adjust/Test Setup Test/Adj. Weights Define Test Sequences Define Tasks Define ProFACT / int. Adj. On Autom. ext.Adjust Off Autom. ext.Test Off Test/Adj. Weights List of 12 Test/Adj. Weights (section 3.1.1) OK Test History Define Protocol Define OK A complete list of the 12 test weights can be printed out by pressing the «F» key while the weight list is displayed. 3.1.1 Weight Parameters Once you have selected a weight, the following parameters can be configured. Test/Adjust Weights Setup Test/Adjust Weight 01 Setup Test/Adj. Weight 1 Define Name Test/Adj. Weight 2 Define Weight ID Test/Adj. Weight 3 Define Class Test/Adj. Weight 4 Define Certificate No. Define Test/Adj. Weight 5 Define Weight Set No. Define Test/Adj. Weight 6 Define Actual Value Test/Adj. Weight 7 Define Next Calibration Test/Adj. Weight 8 Define Test/Adj. Weight 9 Define Test/Adj. Weight 10 Define Test/Adj. Weight 11 Define Test/Adj. Weight 12 Define OK Test/Adj. Weight Define E1 0g 31.12.2099 OK Settings for Adjustment and Tests 9 “Name”: Weight Name can be freely defined and is intended to be an easily recognizable form for the user as an alternative to the Weight ID and Certificate No. (E.g. 20g QK). Max. 20 characters! Name should be unique and unambiguous. “Weight ID”: The ID of the weight is provided on the Weight Certificate.The ID may contain your company specific identification number. Max. 20 characters! “Class”: The following predefined classes are available to choose from: E1, E2,F1, F2, M1, M2, M3, ASTM1, ASTM2, ASTM3, ASTM4, ASTM5, ASTM6, ASTM7, Own. “Own” can be selected when none of the other classes apply. “Certificate No.”: The number of the certificate relating to the weight. Max. 20 characters! “Weight Set No.”: The number of the certificate relating to the set of weights (if the test weight belongs to a set). Max. 20 characters! “Actual Value”: Specified on the Weight Certificate. Independent of the balance model, the complete number should be entered regardless of the number of decimal places (e.g. 20.00124 g). Methods always use the actual value and the maximum decimal places of the balance will be used for computation. “Next Calibration”: Enter the date when the next calibration of the weight is due. If the calibration date is unavailable or if no calibration of the weight is planned, the preset value (31.12.2099) will be retained. Settings for Adjustment and Tests 10 3.2 Test Sequences Test Sequences define which test is to be performed and with which test weights(s). The user is guided through the test with clear instructions on the balance display. The test should be performed in accordance with GWP® or other QM-System. When configuring the Test Sequence you can define the steps to follow should the balance fail the test (see section 3.2.1). In the example illustrated, Test Sequence 1 has the name “Sensitivity”. The rest of the Test Sequences are undefined. Adjust/Test Setup Test/Adj. Weights Define Test Sequences Define Test Sequences Tasks Define Sensitivity Define Name Setup Test Sequence Test Sequence 1 Setup Version 2 Sensitivity ProFACT / int. Adj. On Test Sequence 2 Define Preparation Instructions None Autom. ext.Adjust Off Test Sequence 3 Define Method None Autom. ext.Test Off Test Sequence 4 Define Action if Failure None Test History Define Test Sequence 5 Define Instructions if Failure None Protocol Define Test Sequence 6 Define Code to Unblock Test Sequence 7 Define Entry in GWP History Test Sequence 8 Define Test Sequence 9 Define Test Sequence 10 Define Test Sequence 11 Define Test Sequence 12 Define OK OK Z No OK Settings for Adjustment and Tests 11 When “Test Sequences” is selected you are provided with a list of tests. Up to 12 Test Sequences can be configured. Select an undefined Test Sequence to be configured or the name of a Test Sequence whose parameters you wish to update. Test Sequences Setup Sensitivity Define Test Sequence 2 Define Test Sequence 3 Define Test Sequence 4 Define Test Sequence 5 Define Test Sequence 6 Define Test Sequence 7 Define Test Sequence 8 Define Test Sequence 9 Define Test Sequence 10 Define Test Sequence 11 Define Test Sequence 12 Define OK A complete list of all parameters of the 12 test sequences can be printed out by pressing the «F» key while the test sequence list is open. 3.2.1 Test Sequence Parameters Once you have selected a Test Sequence the following parameters can be configured. The weights required for the test weights must be previously defined in the Test/Adjust Weights menu. Test Sequence Sensitivity Name Sensitivity Preparation Instructions Standard Method Warning Instructions if Failure Standard Entry in GWP History Note: Each time the Test Sequence is saved the Version number will be incremented by 1. The version number is indicated on the top right hand corner of the display when the relevant Test Sequence is open. SE1 Action if Failure Code to Unblock Note: The Test Sequence is saved by pressing “OK” on the Test Sequence menu. Setup Version 2 Note: The SERVICE Method does not require a test weight. Z Yes OK “Name”: The Test Sequence Name can be freely defined and is intended to be an easily recognizable form for the user to ensure clear identification and easy traceability. Max. 20 characters! Settings for Adjustment and Tests 12 “Preparation Instructions”: Choose between two settings: “None” 8: No preparation instructions will be included in your Test Sequence. This is primarily suitable for Test Sequences that do not normally require user interaction, e.g. Test Sequences using the SERVICE Method.For all other Methods,selection of“Standard” is recommended. “Standard”: The following preparation instructions will be included in your Test Sequence and correspond to those typically found in any standard SOP.The user must execute the instructions and confirm with “OK” before being able to continue with the rest of the defined Test Sequence: The Test Sequence “Name” has started. Please carry out the following: 1. Clean the weighing pan. 2. Level the balance. 3. Connect and switch on the printer. 4. Make sure that the test weights are ready. 5. Make sure that the tweezers/weighing forks are ready. When finished - press “OK” and follow the next test sequence instructions. “Method”: The Method defines the type of test to be performed. Choose from a list of six different Methods. On selecting the Method you will be required to define the test weights and tolerances to be utilized for the test. This is described further in section 3.2.3. Factory Setting: None “Action if Failure”: Allows you to define how the balance should behave if a test fails or is aborted. Choose from the following three settings: “None” 8: The user can continue work as normal. “Warning”: “Attempts”: The user can continue work as normal but will receive a specified number of warnings that the Test Sequence has failed and will be prompted to restart the Test Sequence. If the specified number of warnings has been reached and the last restart of the Test Sequence fails, the failed Test Sequence will cause the balance to be blocked. Note: These settings are described further in section 3.2.2. Specify the number of attempts allowed to perform the test. When the number of attempts has been reached and the test has not been successful, the balance will be blocked. In contrast to the Warning setting, it is not possible to continue working on the balance until the test has passed. Choose from 1 8, 2 or 3 Attempts and Until Passed. Until Passed allows unlimited number of attempts. Note: When GWP History is enabled, only the last result and the number of attempts are recorded. Settings for Adjustment and Tests 13 “Instructions if Failure”: Defines instructions for the user that will be displayed after a test fails. This setting does not depend on the parameter “Action if Failure” and appears each time a Test Sequence fails. Choose between two settings: “None” 8: The test “Name” has failed. “Standard”: The test “Name” has failed. The balance is out of your predefined tolerances. Please contact the person responsible in your company or METTLER TOLEDO Service. “Code to Unblock”: If the system has been blocked because of a failed Test Sequence (due to the “Action if Failure” settings), it can be unblocked again with the help of the Test Sequence specific “Code to Unblock”. Note: If “Action if Failure” = None is selected, a failed Test Sequence will never cause the balance to be blocked. Factory setting: Z “Entry in GWP History”: Choose if you want the test result to be stored in the GWP History: “Yes”: “No” 8: Result of the Test Sequence will be saved. Result of the Test Sequence will NOT be saved. Note: The GWP History is capable of saving 120 test results. Due to this limited number you may find it unnecessary to store the results of Test Sequences without quality reference e.g. Test Sequences using the SERVICE Method. Note: Once the GWP History has reached 120 results, the oldest results stored will be overwritten with the new results. A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. For easy traceability and to meet documentation requirements, it is recommended that the settings of the Test Sequence are printed out after each change – the Version number of the Test Sequence is included in the printout. 3.2.2 Settings of the Parameter “Action if Failure” = Warning Action if Failure Sensitivity Setup Version 2 None Warning Define Attempts 1 Warning Sensitivity Warning Message OK Time Interval Max. Number of Warning Action after Failure Setup Version 2 Standard 1h 1 None OK “Warning Message”: Choose the warning message given to the user after a failed Test Sequence.The dialogue box with the warning also has a Start button which can be used to restart the Test Sequence: “Standard” 8: The test “Name” has failed. Please perform the test sequence again. Settings for Adjustment and Tests 14 The test “Name” has failed. Please perform the following: “Advanced”: 1. Check the weighing parameter settings. 2. Perform the test sequence again using the function key or directly using the Start button. Note: To be able to start the Test Sequence using the function key, the relevant Task must already be configured accordingly and the Test Sequence function key enabled. Note: If the “Start” button is disabled (grayed out), the current user profile has insufficient access rights to begin the procedure. “Time Interval”: Define the length of time in hours until the warning should be given again. Intervals from 1 up to 1000 hours can be set. Factory setting: 1 “Max. Number of Warning”: Define the maximum number of warnings allowed for this Test Sequence. If the last warning is reached and the Test Sequence has not yet been successfully executed, the balance will be blocked. Valid inputs are 1 up to 1000. Factory setting: 1 “Action after Failure”: Allows you to define how the Test Sequence should behave after it has been newly started from the warning dialogue. Choose from the following settings: “None” 8: The Test Sequence will be aborted and then restarted after the sequence of the next warning interval. See also Max. Number of Warning. “Attempts”: In contrast to “None”, the balance does not go back to warning mode. The test sequence must be successfully executed according to the number of attempts defined here, or else it will block the balance. The available settings to choose from here are the same Attempts settings as described in section 3.2.1. No further warning messages will be given when the Test Sequence has been successfully executed. If the balance is already blocked, the warning messages will be deactivated by unblocking the system. Settings for Adjustment and Tests 15 3.2.3 The Method A Method describes the type of test to be performed and forms the core of a Test Sequence. The test weight(s) to be used and the associated tolerances must be defined as part of the Method. There are 8 different Methods available. Method Sensitivity Setup Version 2 None “None” 8: No method will be selected “EC”: Method for Eccentricity Test (section 3.2.3.2) “RP1”: Method for Repeatability Test (section 3.2.3.3) EC Define “RPT1”: Method for Repeatability Test with Tare (section 3.2.3.4) RP1 Define “SE1”: Method for Sensitivity Test with 1 Testpoint (section 3.2.3.5) RPT1 Define “SE2”: Method for Sensitivity Test with 2 Testpoints (section 3.2.3.6) SE1 Define “SERVICE”: Method for Service Method (section 3.2.3.7) SE2 Define “SET1”: SERVICE Define Method for Sensitivity Test with Tare and 1 Testpoint (section 3.2.3.8) SET1 Define “SET2”: Method for Sensitivity Test with Tare and 2 Testpoints (section 3.2.3.9) SET2 Define OK 3.2.3.1 Defining Weights and Tolerances for a Method Methods EC, RP1, RPT1, SE1, SE2, SET1 and SET2 require one or more test weights and their associated tolerances to be defined. The process is as follows: 1. Select the test weight for the test 2. Define the test tolerances for the test weight, if applicable 3. Define the result tolerances for the method result Method Sensitivity Selection that appears are the names of the Test/Adj. weights that you have perviously defined (see section 3.1.1) Setup Version 2 None C EC Define RP1 Define RPT1 Define SE1 Define SE2 Define SERVICE Define SET1 Define SET2 Define OK Method Name Sensitivity Setup Version 2 Test Weight Sensitivity Setup Version 2 Tare Weight Define Test/Adj. Weight Define Test Weight Define Tolerances Define OK OK Tol. Test Weight 1 Sensitivity Tolerance T1 Name T1 Tolerance T2 Name T2 Setup Version 2 0.10 g Warn Limit 0.10 g Control Limit OK Settings for Adjustment and Tests 16 Warning: It is important to distinguish between the test tolerances used for the individual weight measurements during the Test Sequence and those that are applied to the results at the end (Methods EC, RP1 and RPT1). 1. Select the Test Weights for the Test On pressing “Test Weight” or “Tare Weight” you can select the desired test weight from the list of previously configured weights. For the Tare Weight select the weight which corresponds to the test weight of the tare container. 2. Define the Tolerances for the Test Each test weight has two associated tolerances (T1 and T2) which are applied to the weight during the Test Sequence as described below: “Tolerance T1”: Tolerance T1 is used as a warning to the user and should therefore be smaller than T2. If this tolerance is exceeded a warning will be generated but the user can still complete the Test Sequence. A record of the warning is stored in the Test History and will be printed in the report. If you do not want T1 to be defined as part of the Test Sequence it can be turned off by setting it to 100 %. “Name of Tolerance 1”: The name of T1 can be freely defined. Max 20 characters! Factory Setting: Name = “Warn Limit” “Tolerance T2”: If Tolerance T2 is exceeded the Test Sequence will be aborted. The user is given the message that the test has failed. The error is stored in the Test History and will be printed in the report. If you do not want T2 to be defined as part of the Test Sequence, it can be turned off by setting it to 100 %. “Name of Tolerance 2”: The name of T2 can be freely defined. Max 20 characters! Factory Setting: Name = “Control Limit” Note: The smallest value shown for Tolerances T1 and T2 depends on the type of balance used and carries 1 digit. 3. Define the Tolerances for the Method Result For the Methods EC, RP1 and RPT1 two further tolerances are applied to the results generated from the Test Sequence. These two tolerances are defined and apply in the same way as those for the test tolerances as described above. Note: When using a Method which calculates an end result, it is advisable to turn off Test and Tare Weight Tolerances by setting them to 100 % to allow the full Test Sequence to be executed and the result tolerance (method tolerance) T2 to be applied. A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. Settings for Adjustment and Tests 17 3.2.3.2 EC Method for Eccentricity Test The aim of the EC Method (Eccentricity Test) is to ensure that any deviation due to eccentricity is within the tolerances required by the user’s SOP. The result is set equal to the largest of the 4 calculated eccentricities (4-7). Method Sequence: 1. Zero 2. Load Test Weight (Center) 3. Tare 4. Reposition Test Weight (to Front Left) 5. Reposition Test Weight (to Rear Left) 6. Reposition Test Weight (to Rear Right) 7. Reposition Test Weight (to Front Right) 8. Unload all weights 9. Zero Method Sensitivity Setup Version 2 None EC Define Method EC Eccentric Load Setup Version 2 RP1 Define Test Weight Define RPT1 Define Define SE1 Define Tolerance for Eccentricity Dev. SE2 Define SERVICE Define SET1 Define SET2 Define OK See section 3.2.3.1 Defining Weights and Tolerances for a Method Tol. for Ecc. Load Eccentric Load Setup Version 2 Tolerance EC T1 0.10 g Name EC T1 Tolerance EC T2 Name EC T2 Warn Limit 0.10 g Control Limit OK “Test Weight”: OK A pre-defined test weight and its corresponding test tolerances can be selected here (see section 3.2.3.1). Note: The tolerances T1 and T2 apply to the individual weight measurements and not to the eccentricity calculation. Note: If you require the eccentricity test to be fully executed the test weight tolerances should be set to 100 %. “Tol for Eccentricity Dev”: The EC Method uses two result tolerances (method tolerances) EC T1 and EC T2 which are applied to the calculated standard deviation of the Test Sequence and functions in the same way as described for T1 and T2 in section 3.2.3.1. If Tolerance EC T1 is exceeded the Eccentricity Test will Pass with Warning. If Tolerance EC T2 is exceeded the Eccentricity Test will Fail. A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. Settings for Adjustment and Tests 18 3.2.3.3 RP1 Method for Repeatability Test The RP1 Method calculates the mean value and standard deviation (symbol s) of a measurement series using a single test weight to determine the repeatability of the balance. Method Sequence: 1. Zero 2. Load Test Weight 3. Unload Test Weight 4. Repeat steps 2 and 3 5. Unload all weights 6. Zero Method Sensitivity Setup Version 2 See section 3.2.3.1 Defining Weights and Tolerances for a Method None EC Define RP1 Define Method RP1 Test Sequence Setup Version 2 RPT1 Define Test weight Define SE1 Define Tolerances (s) Define SE2 Define Number of Repetitions SERVICE Define SET1 Define SET2 Define Tolerances (s) Test Sequence Tolerance s T1 10 OK Name s T1 Tolerance s T2 Name s T2 Setup Version 2 0.000 g Warn Limit 0.000 g Control Limit OK OK Numeric Keypad “Test Weight”: A pre-defined test weight and its corresponding test tolerances can be selected here (see section 3.2.3.1). Note: The test tolerances of the test weight are valid for every individual weight value, but do not apply to the standard deviation that is to be calculated. Note: If you require the repeatability test to be fully executed the test weight tolerances should be set to 100 %. “Tolerances s”: The RP1 Method uses two result tolerances (method tolerances) s T1 and s T2 which are applied to the calculated standard deviation of the Test Sequence and functions in the same way as described for T1 and T2 in section 3.2.3.1. If Tolerance s T1 is exceeded, the Repeatability Test will pass with warning. If Tolerance s T2 is exceeded, the Repeatability Test will fail. “Number of Repetitions”: Define the number of weight measurements in the series. Valid range of input: 2 - 15 Factory Setting: 10 A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. Settings for Adjustment and Tests 19 3.2.3.4 RPT1 Method for Repeatability Test with Tare The RPT1 Method calculates the mean value and standard deviation (symbol s) of a measurement series using two test weights to determine the repeatability of the balance. In contrast to the RP1 Method an extra test weight is used to simulate the use of a tare container. Method Sequence: 1. Zero 2. Load Tare Weight 3. Tare 4. Load Test Weight 5. Unload Test Weight 6. Repeat steps 4 and 5 7. Unload all weights 8. Zero Method Sensitivity Procedure in defining a tare weight is similar to defining a test weight (see section 3.2.3.1 Defining Weights and Tolerances for a Method) Setup Version 2 None EC Define RP1 Define RPT1 Define Method RPT1 Test Sequence Setup Version 2 SE1 Define Tare Weight Define SE2 Define Test Weight Define SERVICE Define Tolerances (s) Define SET1 Define Number of Repetitions SET2 Define OK 10 See section 3.2.3.1 Defining Weights and Tolerances for a Method Tolerances (s) Test Sequence Tolerance s T1 OK Name s T1 Tolerance s T2 Name s T2 Setup Version 2 0.000 g Warn Limit 0.000 g Control Limit OK Numeric Keypad “Tare Weight”: Select the test weight which represents the weight of the tare container from the list of previously configured weights and define the weight tolerances as described in section 3.2.3.1. Note: It is recommended to set the tare weight tolerances to 100 %. “Test Weight”: A pre-defined test weight and its corresponding test tolerances can be selected here (see section 3.2.3.1). Note: The test tolerances of the test weight are valid for every individual weight value, but do not apply to the standard deviation that is to be calculated. Note: If you require the repeatability test to be fully executed the test weight tolerances should be set to 100 %. Settings for Adjustment and Tests 20 “Tolerances s”: The RPT1 Method uses two result tolerances (method tolerances) s T1 and s T2 which are applied to the calculated standard deviation of the Test Sequence. It functions in the same way as described for T1 and T2 in section 3.2.3.1. If Tolerance s T1 is exceeded, the Repeatability Test will pass with warning. If Tolerance s T2 is exceeded, the Repeatability Test will fail. “Number of Repetitions”: Define the number of weight measurements in the series. Valid range of input: 2 - 15 Factory Setting: 10 A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. 3.2.3.5 SE1 Method for Sensitivity Test with 1 Testpoint The SE1 Method tests the sensitivity of the balance using a single test weight. Method Sequence: 1. Zero 2. Load Test Weight 3. Unload all weights 4. Zero Method Sensitivity Setup Version 2 None EC Define RP1 Define RPT1 Define SE1 Define Method SE1 Sensitivity Setup Version 2 SE2 Define Test Weight Define SERVICE Define SET1 Define SET2 Define OK See section 3.2.3.1 Defining Weights and Tolerances for a Method OK “Test Weight”: Select the weight to be used for the test from the list of previously configured weights and define the test tolerances as described in section 3.2.3.1. Note: In this Method the test tolerances apply to the Sensitivity Test. A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. Settings for Adjustment and Tests 21 3.2.3.6 SE2 Method for Sensitivity Test with 2 Testpoints In contrast to SE1 Method, SE2 Method tests the sensitivity of the balance using two test weights. Method Sequence: 1. Zero 2. Load Test Weight 1 3. Unload Test Weight 1 4. Zero 5. Load Test Weight 2 6. Unload all weights 7. Zero Method Sensitivity Setup Version 2 None EC Define RP1 Define RPT1 Define SE1 Define SE2 Define Method SE2 Sensitivity Setup Version 2 SERVICE Define Test Weight 1 Define SET1 Define Test Weight 2 Define SET2 Define See section 3.2.3.1 Defining Weights and Tolerances for a Method OK OK “Test Weight 1”: Select the first weight to be used for the test from the list of previously configured weights and define the test tolerances as described in section 3.2.3.1. Note: In this Method the test tolerances apply to the Sensitivity Test. “Test Weight 2”: Select the second weight to be used for the test from the list of previously configured weights and define the test tolerances as described in section 3.2.3.1. Note: In this Method the test tolerances apply to the Sensitivity Test. A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. Settings for Adjustment and Tests 22 3.2.3.7 SERVICE Method for Reminder / Early Notification The SERVICE Method is a specialized Method which does not require the use of a test weight. It is usually set up to run in the background to regularly check various dates stored in the balance and will often terminate itself without any interaction from the user or without displaying a dialogue. E.g. it is typically employed as a reminder for the next Service date or MinWeigh date – the date will be checked regularly but the user will only receive a dialogue when the defined job becomes due.The SERVICE Method can also be used to provide advanced notification of when a test is due with the Early Warning Alert. Status Method Sensitivity Setup Version 2 None Battery Change 4 Service 4 MinWeigh 4 Weight Cal. 4 EC Define Task 01 4 RP1 Define Task 02 4 RPT1 Define Task 03 4 SE1 Define Task 04 4 SE2 Define SERVICE Define SET1 Define SET2 Define Task 05 4 Method SERVICE Service-Check Setup Version 2 Task 06 4 Status Define Task 07 4 Early Warning Alert 7 Days Task 08 4 Task 09 4 Task 10 4 Task 11 4 Task 12 4 OK OK STD C OK Numeric Keypad Note: In order for this Test Sequence to terminate without interaction from the user the “Preparation Instructions” must be set to “None” (see section 3.2.1). “Status”: Multiple selections are possible from all available options to define which dates should be monitored by this Test Sequence. The user will receive a message when the job is due. The dates of the following are available to choose from: “Battery Change”: Date of the next battery change “Service”: Date of the next Service “MinWeigh”: Date of the next MinWeigh determination “Weight Cal.”: Date of the “Next Calibration Date” for ALL test weights “Task 01 - 12”: Date of the “Next Call Date” of the Task Factory Setting: No item is selected Settings for Adjustment and Tests 23 “Early Warning Alert”: Define how early the warning should appear. E.g. set a reminder for 7 days before the battery is due to be changed. If the test has passed within the Early Warning period, the test will be recorded as “Passed with Warning”. If the Early Warning period has elapsed, the test will fail.The “Instructions if Failure” can provide further instructions to the user (see section 3.2.1). Valid range of input: 1 - 365 days Factory Setting: 7 days Note: Using the Early Warning Alert as a reminder for another Task to be performed requires the creation of two Tasks – one for the original Test Sequence and one for the reminder. Note: Multiple dates can be simultaneously checked with the Service Method (see multiple selections in “Status”). However, the same Early Warning period is valid for all scheduled dates. If varying Early Warning periods are required, several Service Methods must be defined. Note: The reminder Task must be set up to check the dates on a regular basis; choose the frequency of the check in relation to the Early Warning period and the frequency of the Test Sequence to be performed. For information on configuring Tasks, see section 3.3. A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. The SERVICE Method can also be used for the sole purpose of displaying the “Preparation Instructions” e.g. so the user can be informed to level the balance each day. In this special case, set the “Preparation Instructions” to “Standard” in the Test Sequence settings and ensure NO items in the “Method Status” are selected. Settings for Adjustment and Tests 24 3.2.3.8 SET1 Method for Sensitivity Test with Tare and 1 Testpoint The SET1 Method tests the sensitivity of the balance using two test weights. The first test weight is used to simulate the use of a tare container. Method Sequence: 1. Zero 2. Load Tare Weight 3. Tare 4. Load Test Weight 5. Unload all weights 6. Zero Method Sensitivity Setup Version 2 None EC Define RP1 Define RPT1 Define SE1 Define SE2 Define SERVICE Define SET1 Define Method SET1 Sensitivity Setup Version 2 SET2 Define Tare Weight Define Test Weight Define OK Procedure in defining a tare weight is similar to defining a test weight (see section 3.2.3.1 Defining Weights and Tolerances for a Method) See section 3.2.3.1 Defining Weights and Tolerances for a Method OK “Tare Weight”: Select the test weight which represents the weight of the tare container from the list of previously configured weights and define the weight tolerances as described in section 3.2.3.1. Note: The system will first check if the tare weight is within the pre-defined weight tolerances. While the tare weight is left on the balance, the test weight is used to determine the Sensitivity. Note: It is recommended to set the tare weight tolerances to 100 %. “Test Weight”: A pre-defined test weight and its corresponding test tolerances can be selected here (see section 3.2.3.1). Note: In this Method the test tolerances apply to the Sensitivity Test. A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. Settings for Adjustment and Tests 25 3.2.3.9 SET2 Method for Sensitivity Test with Tare and 2 Testpoints In contrast to SET1 Method, SET2 Method tests the sensitivity of the balance using three test weights. The second test weight (Tare Weight) is used to simulate the use of a tare container. Method Sequence: 1. Zero 2. Load Test Weight 1 3. Unload Test Weight 1 4. Zero 5. Load Tare Weight 6. Load Test Weight 2 7. Unload all weights 8. Zero Method Sensitivity Setup Version 2 None EC Define RP1 Define RPT1 Define SE1 Define SE2 Define SERVICE Define SET1 Define SET2 Define OK Procedure in defining a tare weight is similar to defining a test weight (see section 3.2.3.1 Defining Weights and Tolerances for a Method) Method SET2 Sensitivity Setup Version 2 Test Weight 1 Define Tare Weight Define Test Weight 2 Define See section 3.2.3.1 Defining Weights and Tolerances for a Method OK “Test Weights 1 and 2”: Same function as Test Weight in the previous section 3.2.3.8 - SET1 Method. “Tare Weight”: Same function as Tare Weight in the previous section 3.2.3.8 - SET1 Method. A complete list of the settings can be printed out by pressing the «F» key while the Test Sequence menu is open. Settings for Adjustment and Tests 26 3.3 Tasks Test Sequences define which test is to be performed and with which test weight(s). Tasks define when the Test Sequence should be executed and how it should be started. Before a Task can be defined, the Test Sequence and the necessary weights must first be defined. Up to 12 Tasks can be defined. When a Test Sequence is assigned to a Task, its name appears in the Task List as shown in the example below. Tasks Adjust/Test Setup Test/Adj. Weights Define Test Sequences Define Tasks Define ProFACT / int. Adj. On Autom. ext.Adjust Off Autom. ext.Test Off Test History Define Protocol Define OK Sensitivity Setup Manual Task 02 Off Task 03 Off Task 04 Off Task 05 Off Task 06 Off Task 07 Off Task 08 Off Task 09 Off Task 10 Off Task 11 Off Task 12 Off OK A complete list of the 12 tasks can be printed out by pressing the «F» key while the task list is open. Settings for Adjustment and Tests 27 3.3.1 Task State The task can be switched on or off in the task status window as illustrated below.Tasks that are switched off will be ignored by the system. Tasks which are switched on may be modified or updated. Tasks Sensitivity Task State Task Setup Manual Off Task 02 Off On Task 03 Off Task 04 Off Task 05 Off Task 06 Off Task 07 Off Task 08 Off Task 09 Off Task 10 Off Task 11 Off Task 12 Off Setup Manual OK OK Note: The date when the Test Sequence is scheduled to take place will be recalculated as soon as the Task State is saved by pressing “OK”. The due date of the next subsequent occurrence is calculated at the end of each executed Test Sequence. A complete list of the settings can be printed out by pressing the «F» key while the Task State menu is open. 3.3.2 Assigning a Test Sequence to the Task An existing Test Sequence can be assigned to the Task. On selecting “Test Sequence”, the user can select from a list of previously configured Test Sequences. Task State Task Setup Off On Manual OK Task # Setup Test Sequence Define Starting Method Manual Defined Days Define Defined Users Define OK Selection that appears are the names of the test sequences that you have previously defined in the Test Routine List (see section 3.2.1) C Settings for Adjustment and Tests 28 3.3.3 Starting Method Task # Setup Test Sequence Define Starting Method Manual Defined Days Define Defined Users Define OK Starting Method Task # Numeric Keypad Setup Manual On User Change Interval Define On Power On OK Interval Task # Setup Interval Start Time 08:00 Interval 1 Day OK The Test Sequence defined in the Task can be started in 4 different ways. Choose from: “Manual”: The Test Sequence can be started manually at any time by pressing the Test Sequence Function Key on the main balance display. Note: In the Task settings “Defined Days”, the day of the week when the Test Sequence can be started is defined. Note: In the Task settings “Defined Users”, the users who are permitted to start the Test Sequence are defined. See “Defined Days” and “Defined Users” for further information. “On User Change”: When the user profile is changed, the balance will call for the Test Sequence that is defined in the Task to be executed. Note: In the Task settings “Defined Days”, if the day is not activated when the user profile is changed, then the change will take place without the call for the test. Note: In the Task settings “Defined Users”, if the new user profile is not in the Defined Users, then the user change will take place without the call for the test. See “Defined Days” and “Defined Users” for further information. “Interval”: Defines the times at which the balance automatically prompts for the Test Sequence to be performed. “Interval Start Time” The time of day when the test should be done. Range 0:00 until 23:59. Note: In order to ensure that a test is performed before actual work starts on the balance, the Start Time is often set earlier than actually required e.g. Start Time is set to 7.00 when work usually begins at 8.00. Settings for Adjustment and Tests 29 Note: If you change the date/time of the terminal, it is recommended to reset the previously calculated next scheduled call-up of the interval tasks. Do the following steps: 1. 2. 3. 4. 5. 6. Go to the corresponding task menu of the interval task. Switch off the task. Close the menu with “OK” to save the changes (the next scheduled task will be erased). Go back to the task menu that had just been switched off. Switch on the task again. Close the menu with “OK” to save the changes (the next scheduled task will be recalculated and the task is active again). Note: Repeat these steps for all your interval tasks. “Interval” The time, in days, between each test. Range is 1 to 720 days. Note: If a test is not executed at the scheduled time, for example because it occurred on a holiday, it will remain pending. If it remains pending until the next call to perform the test, it is only necessary to carry out the test ONCE. Example: A daily task needs to be executed only once on a Monday even if the same task is pending from the previous Saturday and Sunday. “On Power On”: 3.3.4 If this is activated, the Test Sequence will be started as soon as the balance is plugged to a power outlet.This is especially useful, if the balance has been unplugged from its power supply or if a power outage occurs. Defined Days Define the days of the week on which the Task may be performed. Regardless of the Starting Method used, the Task can only be executed on the selected days. Task # Setup Defined Days Test Sequence Define Monday 4 Friday 4 Starting Method Manual Tuesday 4 Saturday 4 Defined Days Define Wednesday 4 Sunday 4 Defined Users Define Thursday 4 OK STD C OK Note: Test Sequences whose Starting Method is defined as “Manual” will appear in the test selection list only on the Defined Days selected here. Note: Test Sequences whose Starting Method is defined as “On User Change” will be called up only on the Defined Days selected here. Note: Test Sequences whose Starting Method is defined with an “Interval” will be called up only on the Defined Days selected here. If the day when the Test Sequence becomes due is not defined, the Test Sequence will be deferred until the next valid day. Important: Warning dialogues relating to failed tests will still be displayed on days that are not defined! Provided that the current User is defined (see section 3.3.5 below), the Test Sequence may be started directly from the warning dialogue. Settings for Adjustment and Tests 30 3.3.5 Defined Users Define which User Profiles have the right to execute the Task. Regardless of the Starting Method used, the Task can only be executed by the selected Users. Task # Setup Test Sequence Define Starting Method Manual Defined Days Define Defined Users Define OK Defined Users Home 4 User 4 4 User 1 4 User 5 4 User 2 4 User 6 4 User 3 4 User 7 4 STD C OK Note: Test Sequences whose Starting Method is defined as “Manual” will appear in the test selection list only for the Defined Users selected here. Note: Test Sequences whose Starting Method is defined as “On User Change” will be called up only when the new user belongs to the Defined Users selected here. Note: Test Sequences whose Starting Method is defined with an “Test Interval” will be called up only when the user belongs to the Defined Users selected here. If the current user is not defined, the Test Sequence will be deferred until a Defined User logs in. Important: All users will receive a warning of a failed or aborted test. However, the Warning Message is only generated for Test Sequences configured to include a warning in “Action if Failure” (see section 3.2.2). Settings for Adjustment and Tests 31 3.4 ProFACT / int. Adj. ProFACT is Professional Fully Automatic Calibration Technology and provides fully automatic internal balance adjustment using an internal weight based on preselected time and/or temperature criteria. Note: For certified balances (Accuracy Class II according OIML) ProFACT / int. Adj. is always active i.e. it is not possible to switch ProFACT off. Adjust/Test Adjust/Test Setup Setup Test/Adj.Weights Weights Test/Adj. Define Define Test Sequences Sequences Test Define Define WeekdaysTime 1 Tasks Tasks Define Define Time 1 ProFACT // int. int.Adj. Adj. ProFACT On On Autom.ext.Adjust ext.Adjust Autom. Off Off Autom.ext.Test ext.Test Autom. Off Off ProFACT ProFACT Weekdays ProFACT ProFACT Off Off ProFACT / int. Adj. ProFACT / int. Adj. Test History History Test Define Define Protocol Protocol Define Define Setup Setup DefineDefine OK OK Setup Setup Define Define 9:00 Off Time 2 9:00 Time 2 Time 3 Off Off Time 3 Temp. Criterion Off 1 Kelvin 1 Kelvin On Protocol Trigger Advanced Options On On Advanced Options Off Temp. Criterion Protocol Trigger OK OK OK See section 3.4.1 Advanced Options OK The following settings are available: “Off”: ProFACT / int. Adj. fully automatic adjustment is switched off. “ProFACT / int. Adj.”: ProFACT / int. Adj. fully automatic adjustment is switched on (Factory Setting). The behavior of the ProFACT adjustment function can be defined using the “Define” button. “Weekdays”: Define the days on which fully automatic adjustment should be carried out. If you do not wish to have time-controlled adjustment, deactivate all days. Factory setting: All days activated “Time 1”...“Time 3”: For the selected days, you can specify up to 3 different times for the automatic adjustment to take place. Factory setting: “Time 1” = 9:00,“Time 2” and “Time 3” = “Off” “Temp. Criterion”: Define the change in ambient temperature which will trigger the automatic adjustment. If “Off” is selected, automatic adjustment based on the temperature criterion will not take place. Factory setting: Precision Balances: Model-dependent Analytical- and Micro-balances:“2 Kelvin” “Protocol Trigger”: If “On” is selected a record will automatically be printed out whenever the balance undergoes an automatic adjustment. If “Off” is selected, no printout will be made. Factory setting: “On” Settings for Adjustment and Tests 32 “Advanced Options”: 3.4.1 With “Advanced Options”, you are able to further expand the sequence of the ProFACT and the internal adjustments using internal tests. Details are found in the following section 3.4.1. Advanced Options ProFACT Weekdays Setup Define Time 1 9:00 Time 2 Off Time 3 Off Temp. Criterion 1 Kelvin Protocol Trigger On Advanced Options ProFACT / int. Adj. Advanced ProFACT / int. Adj. Advanced Setup Off On Off Define OK OK Setup As Found No Leveling No As Left No Tolerances Blocking Code to Unblock Define No Z OK By turning on the Advanced Options, you can customize the adjustment process according to your requirements. Factory setting: “Off” Choose between the following settings: “As Found”: When the adjustment process is started, an internal test will be executed as an initial test in order to obtain the actual weight. The test will automatically be started when the adjustment process is called up. Factory setting: “No” “Leveling”: If this option is activated, the level of the balance has to be checked. Note: If the balance does not have a level sensor or is out of level, the system will prompt you to level the balance. Factory setting: “No” “As Left”: If this option is activated, a new internal test will be executed as a final test. Factory setting: “No” “Tolerances”: Here, you can define tolerances that were applied in “As Found” (initial test) and “As Left” (final test). See also “Define the Tolerances for the Test” found in section 3.2.3.1 “Blocking”: With this option, you can define if the balance should be blocked when the Tolerance T2 in “As Found” or “As Left” is violated. After the balance has been blocked, it can only be used again when the corresponding code to unblock is entered. Factory setting: “No” Settings for Adjustment and Tests 33 “Code to Unblock”: Here, you can define the code to be used for unblocking a blocked balance by an “As Found-”, adjustment or “As Left-” failure. Factory setting: “Z” 3.5 Automatic Adjustment Using an External Test Weight If you are working with an external test weight, this setting can be used to define the days and time when the balance should provide an adjustment reminder. Further information on the (automatic) adjustment process using an external test/adjustment weight can be found in section 5.4.2 of the Operating Instructions – Part 2. Adjust/Test Setup Test/Adj. Weights Define Test Sequences Define Tasks Define Weekdays ProFACT / int. Adj. On Autom. ext.Adjust Off Autom. ext.Test Off Off Test History Define On Protocol Define Monday Autom. ext. Adjust. Setup Define 4 Friday Tuesday Saturday Wednesday Sunday Thursday OK STD OK Autom. ext. Adjust. Weekdays Time C OK Setup Define 8:00 Numeric Keypad OK The behavior of the automatic external adjustment function can be specified using the “Define” button. The Weekdays and the Time can be defined in the same way as for ProFACT except only one time per day is available. Factory Setting: Automatic external adjustment function switched off (“Off”). “Weekdays”: Define the days on which the adjustment should be carried out. Factory Setting: Monday “Time”: For the selected days, you can specify the time when the automatic adjustment should take place. Factory setting: 8:00 Settings for Adjustment and Tests 34 3.6 Automatic Adjustment Testing Using an External Test Weight If you want to test the adjustments using an external test weight, this setting can be used to define the days and time when the balance should provide the test reminder. Further information on the (automatic) adjustment process using an external test weight can be found in section 5.4.4 of the Operating Instructions – Part 2. Adjust/Test Setup Test/Adj. Weights Define Test Sequences Define Tasks Define ProFACT / int. Adj. On Autom. ext.Adjust Off Autom. ext.Test Off Weekdays Monday Autom. ext.Test Test History Define Off Protocol Define On Setup Define OK 4 Friday Tuesday Saturday Wednesday Sunday Thursday OK Autom. ext.Test Weekdays Time STD C OK Setup Define 9:00 Numeric Keypad OK The behavior of the automatic external test function can be specified using the “Define” button. The same setting options are available as for defining automatic adjustment using an external test weight (section 3.5). Factory Setting: Automatic external adjustment function switched off (“Off”). “Weekdays”: Define the days on which the adjustment test should be carried out. Factory Setting: Monday “Time”: For the selected days, you can specify the time when the adjustment test should take place. Factory setting: 9:00 Settings for Adjustment and Tests 35 3.7 Test History The balance always records all test operations that have been made and saves them in a memory which is specially protected against power failure. The options in the Test History allow you to define which results you want to view and/or print out for documentation purposes. Selection Adjust/Test Setup Test/Adj. Weights Define Test Sequences Define Tasks Define ProFACT / int. Adj. On Autom. ext.Adjust Off Autom. ext.Test Off Manual adjust 4 Temperature 4 Time Adjust 4 STD Adj Hist. Selection Home C OK Setup Selection Define Display Datasets Last 50 Last 50 Last 40 OK Last 30 Last 20 Last 10 Test History Define Test History Protocol Define Adj. History Show Adj. History Selection Define GWP History Show OK Setup OK All results of test sequences whose GWP History = YES ~ << >> OK “Adj. History”: When the “Show” button is pressed, a window appears with a list of the adjustments made. Although the balance permanently records all adjustments made, the list displays only those adjustments that have been selected for display in the “Adj. History Selection” below. Specific data is displayed for every adjustment: date and time, type of adjustment, temperature, leveling.The entire list can be printed out by pressing the «F» key. “Adj. History Selection”: Select the adjustments you want to have displayed in the “Adj. History” above. You can selectively shorten the list (and hence any printout) and therefore arrange it more clearly. Select from Manual, Temperature and Time controlled adjustments. Note: The balance records ALL adjustment operations. The settings in this menu determine which of those operations are displayed on the list. Factory setting: “Manual Adjust”,“Temperature”,“Time Adjust” activated Settings for Adjustment and Tests 36 “GWP History”: When the“Show” button is pressed, a window appears with a list of the results from the Test Sequences. Use the “” and “~” buttons to scroll between pages and the “>>” and “<<” buttons to move between the individual records. The displayed entries can be printed out by pressing the «F» key. The GWP History can store up to 120 entries. Test results will only appear in the history file if enter into GWP History is set to “Yes”. Note: If the memory is full (120 records for GWP History), the oldest operation will be automatically deleted and overwritten with a new record. You should therefore ensure that you print out and archive the list as required by your laboratory to meet documentation standards and provide full traceability of all tests and adjustments made. 3.8 Protocol – defining the Adjustment and Test Reports On selection of “Protocol” you can define the information you wish to be included when printing out the Adjustment and Test Reports. Adjust/Test Setup Test/Adj. Weights Define Test Sequences Define Tasks Define ---- External test ----25.Feb 2010 16:02 Adjustment and test protocol selection Date/Time 4 Certificate No. ProFACT / int. Adj. On User 4 Temperature Autom. ext.Adjust Off Balance Type 4 Nominal Weight 4 Autom. ext.Test Off SNR 4 Actual Weight 4 4 Test History Define SW-Version Diff. Protocol Define Balance ID Levelcontrol Weight ID Signature OK STD 4 C Sample printout of a test using an external test weight (all printout options activated): OK METTLER TOLEDO User Name Home Balance Type XP504 WeighBridge SNR: 1234567890 Terminal SNR: 1234567890 SW WeighBridge 4.xx SW Terminal 5.xx Balance ID LAB-1/4 Weight ID ETW-500/1 Certificate No. MT-223/3 Temperature 21.2 Nominal 500.0000 Actual 500.0005 Diff. 0.0005 °C g g g Balance is levelled Test done Signature ........................ ------------------------ Settings for Adjustment and Tests 37 Select the box to have the relevant information included i.e. when a box is ticked, the information will be printed. “STD” restores the factory default settings. “OK” saves your modifications. “C” exits the menu without saving. The following record information can be included in the report: “Date/Time”: The date and time of the adjustment are printed in the defined date and time format. Date and Time settings can be found in section 3.6 of the Operating Instructions – Part 2 for XP Balances. “User”: The name of the user profile which was active when the adjustment was made (not for automatic ProFACT adjustment). “Balance Type”: This information describes the weighing platform and the terminal and cannot be changed by the user. “SNR”: The serial numbers of both the terminal and the weighing platform.This information cannot be changed by the user. “SW-Version”: Two numbers for the balance firmware, one for the terminal and one for the weighing platform. “Balance ID”: The identification number of the balance. Balance Information Settings can be found in section 3.4 of the Operating Instructions – Part 2 for XP Balances. “Weight ID”: The identification number of the external test weight used (section 3.1.1). “Certificate No.”: The number of the certificate relating to the external test weight used (section 3.1.1). “Temperature”: Temperature at the time of the adjustment or tests. “Nominal Weight”: The actual weight of the external test weight used for the adjustment/test (section 3.1.1). “Actual Weight”: The actual weight recorded of the external test weight (only when testing using an external test weight). “Difference”: The difference between the nominal weight and the actual weight (only when testing using an external test weight). “Levelcontrol”: States whether the balance is leveled correctly. “Signature”: An additional line is printed for signing the record. Factory setting: “Date/Time”,“User”,“Balance Type”,“SNR” (serial number),“Nominal Weight”,“Actual Weight”,“Difference” and “Signature” are activated. Glossary 38 4 Glossary - GWP Functions The following are technical terms and its definitions used in this manual. Actual Value Specified value on the Weight Certificate of an external weight. Independent of the balance model. Actual Weight The actual weight recorded of the external weight. Adjustment Setting of sensitivity on the balance. This requires at least a reference weight that is placed on the balance manually or by a mechanically-driven device.This will be weighed and the obtained value will be saved. The sensitivity of the balance will subsequently be corrected in order to obtain the required measurement. Adjustment Weight External weight for adjustment. Calibration Checking of external weight and issuance of a certificate thereafter. Control Limit Tolerance of a process relative to its target value. Violation of the tolerance is an infringement of the quality requirements, and therefore requires a correction of the process. Corner Load Deviation Deviation of weight value, caused by putting load not in the center of the platform. Corner Load Test The aim of the EC Method (Eccentricity Test) is to ensure that any deviation due to eccentricity is within the tolerances required by the user’s SOP. The result is set equal to the largest of the 4 calculated eccentricities. External Adjustment Weight External weight for adjustment. External Test Weight External weight used for testing of adjustment. External Weight Retractable external adjustment or test weight. GWPBase™ Service that gives you a personalized document containing precise recommendations for routine testing of your balance: • How to test your balance and when (how often) • Which weights should be used • What tolerances are appropriate GWPExcellence™ Collection of embedded safety functions for XS/XP Balances. The balance actively supports your routine test requirements by prompting you to execute user guided test procedures, which you have predefined. GWP History Test history of tasks that where done based on the defined test sequence. Internal Adjustment Weight Built-in weight for adjustment. Internal Test Weight Built-in weight used for testing of adjustment. Internal Weight Built-in weight. Method A method describes the manner how a test is to be executed and formulates the core task of a test sequence. The weights to be used and the corresponding test or method tolerances must be defined as part of the method. Method Tolerances Tolerance that defines how much margin of error is allowed for the end result of a method. Minimum Weigh The smallest possible weight value that allows to fulfill the requirements of the relative precision (MinWeigh). ProFACT ProFACT (Professional Fully Automatic Calibration Technology) fully adjusts the balance automatically based on a pre-defined temperature criteria. Repeatability Capability of the balance to show consistent readings in repeated weighings using the same weight and under the same external conditions. Repeatability Test Checking of Repeatability. Result Tolerances Tolerance that defines how much margin of error is allowed for the end result of a method. Routine Checks Execution of different routine tests for balance checking. Routine Test Routinely executed test. Glossary 39 Sensitivity The drift of the weight value divided by the causing load drift. Sensitivity Test Checking of sensitivity. Task Tasks define when the test sequence should be executed, how it should be started and for XP balances, which user should do the test sequence. Before a task can be defined, the test sequence should already be defined. Test Collective term for the checking of a single function or a whole device. Test Sequence Describes the manner of test (method) and with which weight this test should be executed. Furthermore, you also define the behaviour of the balance if the test fails. It also describes the tolerances for the test weight. Test History History of internal and external tests. It is a record of the test results that have been recorded in a memory that is specially secured against power failure. The options in the test history allows you to choose which results you want to view or print out in the documentation. Test Tolerances Tolerance that defines how much margin of error is allowed for an individual weight measurement in a test. Test Weight An external weight piece which is used as reference measurement. Testing of Adjustment Corresponds to the sensitivity test in accordance to GWPExcellence™ Nomenclature. Warning Limit Tolerance of a process relative to its target value. Violation of this limit is not in itself an infringement of the quality requirements, but indicates drift of the process and therefore requires more intensive monitoring of the process. Weight Tolerances a) Tolerances of external weights that are specified on the certificate, or b) Tolerances that pertain to a measured weight (Ex. Tare weight). Index 40 5 Index A Action after Failure 14 Action if Failure 12 Actual Value 9 Actual Weight 37 Adj. History 35 Adj. History Selection 35 Adjust/Test 6 Administrator 6 Advanced Options 32 As Found 32 As Left 32 Attempts 12, 14 Automatic Adjustment 33 Automatic Adjustment Testing 34 B Balance ID 37 Balance Info 6 Balance Type 37 Battery Change 22 Blocking 32 C Certificate No. 9, 37 Class 9 Code to Unblock 13, 33 Control Limit 16 D Date/Time 6, 37 Days 31 Defined Days 29 Defined Users 30 Difference 37 E Early Warning Alert 23 Eccentricity Test 17 EC Method for Eccentricity Test 17 Entry in GWP History 13 External weights 8 G Glossary 38 Good Weighing Practice™ 4 GWPBase™ 4 GWPExcellence™ 4, 39 GWP Functions 38 GWP History 36 I Instructions if Failure 13 Interval 28 Introduction 4, 38 L Levelcontrol 6, 37 Leveling 32 M Manual 28 Max. Number of Warning 14 Method 12, 15 MinWeigh 22 N Name of Tolerance1 16 Name of Tolerance2 16 Next Calibration 9 Nominal Weight 37 Number of Repetitions 18, 20 O On Power On 29 On User Change 28 P Peripherals 6 Preparation Instructions 12 ProFACT / int. Adj. 31 Protocol Trigger 31 R RP1 Method for Repeatability Test 18 RPT1 Method for Repeatability Test with Tare 19 S SE1 Method for Sensitivity Test with 1 Testpoint 20 SE2 Method for Sensitivity Test with 2 Testpoints 21 Service 22 SERVICE Method for Reminder / Early Notification 22 SET1 Method for Sensitivity Test with Tare and 1 Testpoint 24 SET2 Method for Sensitivity Test with Tare and 2 Testpoints 25 Signature 37 SNR (serial numbers) 37 Standby-Modus 6 Starting Method 28 Status 22 SW-Version 37 Index 41 T Tare Weight 19, 24, 25 Task 26 Task 01 - 12 22 Task List 26 Task State 27 Temp. Criterion 31 Temperature 37 Test History 35 Test Sequence Name 11 Test sequences 10 Test Sequence Version Number 11 Test Weight 17, 18, 19, 20, 24 Test Weight 1 21, 25 Test Weight 2 21, 25 Time 33, 34 Time 1... Time 3 31 Time Interval 14 Tolerances 32 Tolerances s 18, 20 Tolerance T1 16 Tolerance T2 16 Tol for Eccentricity Dev 17 U User Name 37 W Warning 12 Warning Message 13 Weekdays 33, 34 Weight Cal. 22 Weight ID 9, 37 Weight Name 9 Weight Set No. 9 Leer GWP® – Good Weighing Practice™ The global weighing guideline GWP® reduces risks associated with your weighing processes and helps to • choose the appropriate balance • reduce costs by optimizing testing procedures • comply with the most common regulatory requirements www.mt.com/GWP www.mt.com/excellence For more information Mettler-Toledo AG Laboratory & Weighing Technologies CH-8606 Greifensee, Switzerland Tel. +41 (0)44 944 22 11 Fax +41 (0)44 944 30 60 www.mt.com Subject to technical changes © Mettler-Toledo AG 10/2010 11781338A 2.12 *11781338*