E ERCO GmbH Postfach 24 60 58505 Lüdenscheid Brockhauser Weg 80-82 58507 Lüdenscheid Germany Tel.: +49 2351 551 0 Fax: +49 2351 551 300 info@erco.com www.erco.com Lightmark Floorwashlight Mounting instructions 3000045270 0615 1 Choosing the mounting location Luminaire not suitable for covering with thermal insulation material. - Lateral air space according to EN 60598: The distance between the surface of the luminaire and any parts of the building must be no less than 50mm. - Recess depth according to EN 60598: No minimum distance is required between the back of the luminaire and any parts of the building. - The luminaire must be positioned so as to avoid operation in direct sunlight or near other sources of heat. High ambient temperatures can reduce the life and efficiency of the control gear or LED module. Electrical installation To avoid any damage to the electronic control gear on a 3-circuit installation, the neutral conductor of electronic control gear must never be interrupted. Over-voltage protection To protect electronic control gear from voltage spikes, e.g. when switching inductive loads, separate overvoltage protection units may be used. Notes on corrosion protection Ensure that the powder coating is not damaged during installation or maintenance work. Any damage, which becomes wet, can result in corrosion occurring. In aggressive environments, the installation and maintenance of all parts will require the appropriate protective measures. Chemicals damage the corrosion protection. English Read the instructions carefully before installation and commissioning! Leave the instructions for users/ customers for future reference! Our continually updated product documentation can be accessed at www.erco.com/download. General safety information Warning! Risk of electric shock! Before carrying out maintenance and installation on the luminaire, disconnect from the mains supply and ensure that all power is switched off. Attention! - Do not operate luminaires with da­maged or missing protective covers. - Do not open the luminaire. In case of damage or a defective LED module, the entire luminaire must be returned to the factory. - When installing, always observe the national installation and accident prevention regulations. Intended use - The luminaire is suitable for both outdoor and indoor use. - The luminaire is approved for wall mounting only. - The recommended mounting height for the luminaire is 0.8m. Restrictions The luminaire is approved for a mounting height of up to 5m. Mounting - Use the supplied frame to mount the luminaire in the cavity wall or in brickwork. - Flush mounting in a cavity wall requires an additional covering or further plastering. - A concrete housing for mounting the luminaire in concrete or in plastered brickwork is available as an accessory. Cavity wall 1. Prepare a wall opening. 2. Insert the mounting frame. 3. Place 4 mounting brackets from the outside into the long holes of the frame and secure the frame (Fig. 5). Note for flush mounting: Apply second covering or plastering prior to inserting the luminaire (Fig. 7). 4. Make the electrical connection via a terminal (to be provided on-site) and junction box (to be provided on-site). Terminal requirements: - 3-pole screw terminal or screwless terminal - 250V min. - 1A min. - Prepare conductor ends as specified by the terminal manufacturer. - Always fit the terminal in a suitable junction box or branch sleeve in compli- ance with the national regulations. 5. Insert the luminaire into the frame without tools. Brickwork Note: The clearances specified in Fig. 1 do not apply to mounting in brickwork. 1. Prepare an installation opening, leaving space for a junction box. 2. Insert the mounting frame. The holes on the back may be used to fix the mounting frame. The outer edge of the frame must be flush with the wall surface. Note for flush mounting: The outer edge of the frame must sit flush with the plastered wall surface. 3. Plaster the frame and fill in the hole. 4. Make the electrical connection via a terminal (to be provided on-site) and junction box (to be provided on-site). Terminal requirements: - 3-pole screw terminal or screwless terminal - 250V min. - 1A min. - Prepare conductor ends as specified by the terminal manufacturer. - Always fit the terminal in a suitable junction box or branch sleeve in compliance with the national regulations. 5. Place the luminaire in the frame. Concrete housing (accessory) Follow the accessory instructions. local facility available for the disposal or recycling of electronic products. Removing the luminaire Surface-mounted luminaire Carefully lift the luminaire out of the frame using a flat object (e.g. screwdriver). Flush-mounted luminaire Remove the luminaire from the frame using a suction cup, e.g. ERCO accessory 33799. Flashing of the LED module It is normal for the LED module to flicker when switching on and off. Dimming The luminaire cannot be dimmed. Cleaning Regular cleaning is essential. The required intervals and methods depend on the mounting location, the mounting situation and the ambient conditions. Outside cleaning of the luminaire Clean with a damp, soft cloth. Take care not to damage the powder-coating. Cleaning the safety glass Safety glass can be cleaned with cleaning agents that are also suitable for glass-ceramic cooking hobs. Disposal In accordance with EU Directive WEEE (Waste Electrical and Electronic Equipment), luminaires must not be disposed of with other household waste. At the end of their life, luminaires must be taken to the appropriate 3000045270 2