General Specifications Diaphragm Measurement Systems For Use With DPharp Family of Pressure Transmitters GS SLC21A0-02E-A ■ GENERAL Our remote seal Diaphragm Measurement System is commonly used when process-operating conditions extend beyond the normal operating limits of a pressure transmitter. In addition, they are used to reduce the weight of the device at the process connection, particularly with conventional pressure transmitters. The lightweight design of DPharp pressure transmitters combined with a robust direct-mounting system provide an excellent solution for both close-coupled and remote seal applications. For service where one or more of the following conditions exist: ■ High temperature ■ Clogging potential ■ Frequent cleaning requirements ■ Aggressive or abrasive processes ■ ANSI flanged including flush and extended process connections ■ NPT threaded process connections ■ Sanitary connections including aseptic, gpc quick connect, tri-clamp, cherry burrell, and tank spud. ■ Saddle seal for welding into pipe line. Materials of Construction Lower Housing (Wetted) Carbon Steel Hastelloy C-276 Monel 400 316 Stainless Steel 316L Stainless Steel Titanium - Grade 4 Tantalum Plate (Wetted Surface Only) Seal Process Connections 1/2" through 2" NPT, 1" through 4" flanged, 2-4-6" Extended Diaphragm, 3" to 12" Saddle Weld, 2" and 6" Tank Spud, Triclamp, Cherry Bushell and Aseptic Sanitary Connections The diaphragm is completely welded, with general construction conforming to methods described in ASME standard B20.2-1991 section 2.3. Upper Housing Carbon Steel 316 Stainless Steel Monel 400 Titanium Connection Ratings 150# RF 300# RF 600# RF Sanitary Diaphragm Materials PTFE Lined 3166 Hastelloy C-276 Monel K500 316L Stainless Steel Tantalum Titanium Flushing Connections Single and Dual 1/4 NPT Single and Dual 1/2 NPT Capillaries and Connections 316SS Armored Capillary 316SS PVC Coated 316SS, 4" Cooling Element Note: Not all wetted parts materials are listed in the model numbers. Please contact your Yokogawa Representative for further informations. Yokogawa Corporation of America 2 Dart Road Newnan, Georgia U.S.A. 30265 Tel: 1-800-258-2552 Fax: 1-770-254-0928 GS SLC21A0-02E-A ©Copyright 2004 2nd Edition 1/04 2 ■ INTRODUCTION Advantages include: The direct-mount seal (DMS) system provides a closecoupled connection to DPharp digital pressure transmitters meeting process connection requirements in food and beverage, biotech, pharmaceutical, chemical, and many other industries. When used with DPharp s unique auto-level software feature, DMS transmitters offer a lower cost of ownership than our competitors. ■ For level measurement The DMS mounting system is designed for direct mounting to any DPharp pressure capsule body, thus maintaining standard sealing characteristics while providing superior structural integrity. The process connection itself is directly welded to the DMS flange, thereby eliminating potential leak paths common to threaded connections utilized on conventional transmitters. Other DMS expanded capabilities include a wide variety of exotic alloys and custom flanged or threaded process connections. • close coupling to the tank • reduced temperature effect • eliminates elevation/suppression calculations • minimizes start-up and installation ■ For sanitary measurement • close coupling to the tank, vessel or piping • reduced weight • reduced temperature effect • minimizes start-up and installation ■ For application flexibility and compatibility • variety of wetted materials selection • variety of fill fluid selection ■ BENEFITS Direct-mount systems eliminate the use of filled capillaries leading to overall performance improvements and a reduction in installation and maintenance costs. Minimizing internal fluid volume reduces the amount of temperature effect as a result of fluid expansion. Eliminating filled capillaries reduces the need for supporting mounting peripherals while greatly minimizing start-up by eliminating the need for calculation of suppression or elevation due fluid head. Major DMS benefits include: ■ Direct-mount system for DPharp digital pressure transmitters ■ Elimination of threaded connections at the transmitter body ■ COOLING ELEMENT ■ Maintains transmitter sealing characteristics ■ Improved structural integrity over typical threaded designs ■ Universal adaptation for a variety of industry standard or custom process connections ■ Expanded offering or exotic alloys 2.75" Available for selection on Threaded seals is a 4" cooling element for direct-mount. Intended to protect the EJA530/510 from high or low process temperature. Air flow across heat exchanging fins reduces or increses the temperature of the system fill fluid to protect the transmitter. The cooling element is recommended for process temperatures approaching transmitter temperature limits. It is direct mounted between the EJA530/510 and the diaphragm seal. Silicone fill is recommended. Effective temperature reductions of 200°F depending upon ambient conditions. All 316SS construction back welded to stainless steel upper housing or flange. 3 Functional Specifications (EJA Pressure Transmitters) *Refer to specific General Specification for more data Span and Range Limits (EJA110A) Measurement Span and Range M Span Range H Span Range V Span Range in H2O 4 to 400 -400 to 400 20 to 2000 -2000 to 2000 20 to 2000 -71 to 2000 Max Working Pressure 2300psi 2300psi 2300psi Span and Range Limits (EJA430A) Measurement Span and Range A Span Range B Span Range psig 4.3 to 430 -15 to 430 20 to 2000 -2000 to 2000 Max Working Pressure 430psi Ambient Humidity Limits: 5 to 100% RH @ 104°F (40°C) EMC Conformity Standards: For EMI (Emission) — EN55011 AS/NZS 2460 1/2 For EMS (Immunity) — EN50082-2: 1995 Supply Voltage: 10.5 to 42 VDC for operation, 16.4 to 42 VDC for digital communications. Load: 0 to 1335 ohms for operation 250 to 600 ohms for digital communications. Physical Specifications (EJA Pressure Transmitters) Bolting: SUS630 Stainless Steel Also available, SUH660S.S. and SCM435C.S. 2000psi Zero Adjustment Limits: Zero can be fully elevated or suppressed, within the Lower and Upper Range Limits of the Capsule. External Zero Adjustment: External zero is continuously adjustable with 0.01% incremental resolution of span. Span may be adjusted locally using the digital indicator with range switch. Stability: ±0.1% of URL per 60 months Housing: Low copper cast aluminum alloy with polyurethane paint -standard (Munsell 0.6GY3.1/2.0) Epoxy paint or SS housing options available Enclosure Classification: JIS C0920 (Equivalent to NEMA 4X and IEC IP67) Weight: 8.6 lbs. (3.9 kg) without integral indicator, mounting bracket and process connector. Data Plate and Tag: SUS304 Stainless Steel Output: Two wire 4 to 20 mA DC output with digital communications, linear or square root programmable. BRAIN or HART FSK protocol is superimposed on the 4 to 20 mA signal. Also available, Digital Communication via Foundation Fieldbus protocol. Ambient Temperature Limits: Approval codes may affect temperature limits -40 to 85°C (-40 to 185°F) -30 to 80°C (-22 to 176°F) with LCD Display Process Temperature Limits: Dependent on seal type and fill fluid selection. Transmitter Capsule Limits: -40 to 248°F (-40 to 120°C) Cover O-Ring: Buna N 4 Fill Fluids We provide a wide array of fill fluids, which will encompass the majority of applications. Table 3 below shows the fill fluids available and the physical parameters of each. Code A B C D E F G H J K L M Fill Fluid Description Silicone 200-10 Silicone 704 Halocarbon® 6.3 Neobee M-20 Pure Glycerin Ethylene Glycol High-Temp Blend Low-Temp Blend Silicone 200-350 Vegetable Oil Flurolube® 6.3 Mineral Oil Temperature Limits ºF ≥ 15psig -40 to 400 30 to 500 -40 to 347 -10 to 400 60 to 462 -30 to 300 -4 to 750 -130 to 356 0 to 572 14 to 400 -40 to 392 5 to 482 Temperature Limits °F <15psig -40 to 250 78 to 280 -40 to 176 -10 to 200 N/A N/A 14 to 392 -130 to 176 N/A 14 to 200 N/A 5 to 340 Specific Gravity 0.934 1.07 1.97 0.92 1.26 1.12 1.07 0.91 0.97 0.94 1.86 0.88 Thermal Exp. 1/°C 0.00104 0.0008 0.00084 0.00101 0.0005 0.00062 0.0008 0.00108 0.00096 0.00082 0.00087 0.00065 Viscosity -cSt@ +77F 10 39 14 (68°F) 9.5 1110 (68°F) 30 39 4 (68°F) 350 66 5 (68°F) 270 Notes General HT, Vacuum See Note 1 & 2 Food Grade Food Grade Low Temperature HT, Vacuum LT, Vacuum Food Grade Food Grade See Notes 1 & 2 Food Grade Note 1: Not to be used in contact with aluminum Note 2: For use when inert liquids are required Model Numbers The following shows the structure of various model numbers in order to create the appropriate seal configuration for your requirements. Select the required type of seal, and then proceed through model number construction. A brief description of the base models is as follows; Pressure Rating: 150#, 300#, 600# per ASME B16.5 Suitable Pressure Ranges: 10" H20 to maximum flange rating, depending on diaphragm size and process conditions. Operating Temperature Range: -130°F to 752°F (-90°C to 400°C) Standard Features Instrument Connection: Direct mount or axial capillary up to 30 ft. (>30 ft. consult factory), SS armored, SS PVC coated Process Connection: 150#, 300#, 600# flange per ASME B16.5 Process Connection Sealing Face: 2", 3", or 4" raised face per ASME B16.5 Flange Material: 316L SS Wetted Material: 316L SS, Monel, Hastelloy C-276, Tantalum, Titanium Installation: Use appropriate gasket, bolts, and nuts, per ASME B16.5 (not supplied with seal) Pancake Seal (WIKA 990.28): This type of seal is usually mounted between two flange connections. It is effectively clamped or "sandwiched" between the two flanges. Typical sizes are 2"-4" with 3" being the most common. Pressure Rating: 150# & 300# per ASME B16.5 (higher pressures available upon request) Suitable Pressure Ranges: 10" H20 to maximum flange rating, depending on diaphragm size and process conditions. Operating Temperature Range: -40°F to 752°F (-40°C to 400°C) Standard Features Instrument Connection: Radial capillary up to 30 ft. (>30 ft. consult factory), SS armored SS PVC coated Process Connection Sealing Face: 2", 3", or 4" raised face per ASME B16.5 Upper Housing Material: 316SS Diaphragm Material: 316SS, Hastelloy C-276, Tantalum (572°F), Monel, Titanium Installation: Use appropriate gasket, bolts, nuts, and blind flange per ASME B16.5 (not supplied with seal) Flush Flanged (WIKA 990.27): This seal provides a direct flange connection, with the diaphragm welded to the sealing surface. These are available in 2"-4" process connections. Extended Flanged (WIKA 990.29): Same basic construction as the Flush flanged except that the diaphragm is attached to an extended barrel which is typically used on jacketed tanks. Process connection sizes are 3" and 4" with extensions available in 2", 4" and 6". Pressure Rating: 150#, 300#, 600# per ASME B16.5 Suitable Pressure Ranges: 10" H20 to maximum flange rating, depending on diaphragm size and process conditions. Operating Temperature Range: -130°F to 752°F (-90°C to 400°C) Standard Features Instrument Connection: Direct mount or axial capillary up to 30 ft. (>30 ft. consult factory), SS armored SS PVC coated Process Connection: 150#, 300#, 600# flange per ASME B16.5 5 Process Connection Sealing Face: 3", or 4" raised face per ASME B16.5 Diaphragm Extension Lengths: 2" (50mm), 4" (100mm), 6" (150mm), Schedule 40 Flange Material: 316/316L SS Extension and Raised Face Material: 316L SS, Hastelloy C-276, Monel, Tantalum (572°F) Diaphragm Material: 316L SS, Hastelloy C-276, Monel, Tantalum (572°F) Installation: Use appropriate gasket, bolts, and nuts, per ASME B16.5 (not supplied with seal) Remote Flanged (WIKA 990.12.601): These seals use a lower housing to provide the process connection. A 2.4" diaphragm is used, and comes in process connection sizes of .5" to 2" (>2 consult factory) Pressure Rating: 150#, 300#, 600# per ASME B16.5 Suitable Pressure Ranges: 100" H20 to maximum flange rating, depending on diaphragm size and process conditions. Operating Temperature Range: Up to 752°F (dependent upon materials) Standard Features Instrument Connection: Direct mount for EJA530/510 or axial capillary up to 30 ft. (>30 ft. consult factory), SS armored, SS PVC coated Process Connection: 150#, 300#, 600# flange per ASME B16.5 Process Connection Sealing Face: .5", 1.0", 1.5", or 2" raised face per ASME B16.5 Upper Housing Material: 316SS Diaphragm: 316L SS Hastelloy C-276, Monel, Tantalum (572°F) Gasket: (between upper and lower housing) Viton, Max. temperature 400°F (204°C) used with 316L dia. (SSS), Teflon, Max. temperature 500°F (260°C) used with all others Lower Housing Material: 316 SS, Hastelloy C-276, Monel, 316 SSTantalum-lined or Titanium Clamp, Support Ring, Nuts and Bolts: 300 series SS, max. temperature 500°F (260°C) Threaded Connection (WIKA 990.10.501): These seals also use a lower housing and come with a 2.4" diaphragm. Process connection sizes are available in 1/2", 3/4" and 1" NPT-F threads. (other sizes may be accommodated—please call) Pressure Rating: 3675 PSI Suitable Pressure Ranges: 15 PSI to 3675 PSI Operating Temperature: Up to 752°F (dependent upon materials) Standard Features Instrument Connection: Direct mount for EJA530/510 or axial capillary up to 30 ft. (>30 ft. consult factory), SS armored, SS PVC coated Process Connection: .5" NPT, .75" NPT, 1" NPT (female) Upper Housing Material: 316 SS Diaphragm Material: 316L SS, Hastelloy C-276, Monel, Tantalum (572°F) Gasket: (between upper and lower housing) Viton, Max. temperature 400°F (204°C) used with 316L dia. (SSS), Teflon, Max. temperature 500°F (260°C) used with all others Lower Housing Material: 316 SS, Hastelloy C-276, Monel, or Titanium Clamp, Support Ring, Nuts and Bolts: 300 series SS, max. temperature 500°F (260°C) Sanitary (WIKA 990.22 & 981.22): These seals are used in processes, which require quick disconnect for ease of cleaning. The connection itself does not allow collection of material, which can potentially create bacterial growth. Process connections are available in TriClamp, Cherry Burrell, In-Line sanitary, Tank Spud, Aseptic, "APC" Quick connect and GC "H" Line. Also, these seals allow for Close Coupled Connection (CCC) to the EJA 530/510 direct mount transmitters. Refer to GS1C21F1-E for product information. Traditional: Pressure Rating: See table Process Connection 1.5" 2" 2.5" 3" 4" Material All All All All All 316SS 316SS 316SS 316SS 316SS Pressure Rating 600 PSI 550 PSI 450 PSI 350 PSI 250 PSI Effective Diaphragm diameter 1.3" 1.6" 2.1" 2.9" 3.5" Suitable Pressure Ranges: 15 PSI to 600 PSI (1000 PSI) [by using the appropriate clamping device.] Operating Temperature Range: -22°F to 400°F (-30°C to 205°C) Standard Features Instrument Connection: Direct mount or axial capillary up to 30ft., SS armored Process Connection: 1.5", 2", 2.5", 3", & 4 Tri-Clamp CherryBurrell I-Line and Q-Line, Aseptic connection, APC quick connect, GC H-Line, 4" tank spud Upper Housing Material: 316L SS, Hastelloy C-276 Diaphragm Material: 316L SS, Hastelloy C-276 In-Line: Pressure Rating: 6 Low-Range (WIKA 990.40 & 990.41): These seals are designed for applications with smaller measurement spans (≤ 150 w.c.). An expanded lower housing is used to accommodate a 3.5" diaphragm. As with other lower housing, this can also function with a flushing ring when a flushing connection is selected. Process connections are available in a variety of sizes from 1/2" to 4" in flanged-direct mount, remote flange and remote flange threaded designs. Pressure Rating: 150#, 300#, 600# per ASME B16.5, or 1500 PSI-Threaded Suitable Pressure Ranges: From 10" H20 to max. flange rating or 1500 PSI-for threaded connection Operating Temperature Range: -40°F to 752°F (-40°C to 400°C) Standard Features Instrument Connection: Direct mount or axial capillary up to 30 ft. (>30 ft. consult factory), SS armored, SS PVC coated Process Connection: 0.5" to 4.0" Upper Housing Material: 316 SS Diaphragm: 316L SS, Hastelloy C-276, Monel, Titanium, Tantalum (max. 572°C) Gasket: Viton, max. temperature 400°F (204°F) Lower Housing Material: 316 SS, Hastelloy C-276, Monel, Titanium, Tantalum lined 316 Bolts: 300 series SS, max. temperature 500°F (260°C) Saddle (WIKA 910.20): These seals support a saddle weld process connection, designed for pipe line pressure measurement. Pressure Rating: 1500 PSI; depending on pipe size Suitable Pressure Ranges: 15 PSI to 1500 PSI Operating Temperature Range: 0°F to 482°F (-12°C to 250°C) Standard Features Instrument Connection: Direct mount for EJA530/510 or axial capillary up to 30 ft. (>30 ft. consult factory) Piping Size: 3" to 12" pipe Transmitter: Most typical remote seal applications are supported by the EJA110A (DP) and EJA430A (Gauge) transmitters. To meet process requirements, other DPharp transmitters can be fitted with diaphragm seals: EJA130A DP cells and EJA440A/310A/510A/530A GP/AP. Follow the model code configuration as listed in the specific instrument s GS sheet. ■ Diaphragm Size The error induced in a system can be greatly affected by differential temperature (between the process and the fill fluid) and by the spring constant of the diaphragm used. An error in a filled capillary system can be calculated by the following equation: Error (in. H2O) = (˘ T) (Et) (Rs) Vt) ∆T The differential temperature change Et The coefficient of thermal expansion of the fill fluid Rs The diaphragm spring constant Vt The volume of the fill fluid subjected to temperature change The following graph shows the comparison of two different diaphragm sizes and their effect on total error induced. Error vs. Temperature 25 Error H2O 600 PSI (1000 PSI) [by using the appropriate clamping device] Suitable Pressure Ranges: 15 PSI to 600 PSI (1000 PSI) [by using the appropriate clamping device] Operating Temperature Range: -130°F to 752°F (-90°C to 400°C) Standard Features Instrument Connection: Direct mount for EJA530/510 or axial capillary up to 30 ft. (>30 ft. consult factory), SS armored, SS PVC coated Process Connection: .75", 1", 1.5", 2", 3", 4", Tri-Clamp Body: 316L SS, Hastelloy C-276 Diaphragm: 316L SS, Hastelloy C-276 20 15 10 2.5" seal 4.0" seal 5 0 0 10 20 30 40 50 60 70 80 90 100 ∆T This does not necessarily mean that a bigger diaphragm is required. When a gauge pressure transmitter is being used at pressures higher than 100psig, a smaller diaphragm can be used. Also, if a system has a large ∆T between the process and ambient temperature but the system is stable, such that this temperature difference is constant, the two legs of the system will compensate and the error can be zeroed out of the system. the following is a quick pick chart for reference. Transmitter Span 10 to 100 H2O 100 to 1000 H2O 30 to 200 psi 200 to 1000 psi Suggested Diaphragm Size ≥ 3" ≥ 2.4" ≥ 2" ≥ 1" 7 Transmitter Model Codes Model EJA110A Output Suffix Codes -D -E Measurement Span (Capsule) Wetted Parts M H V S Connection Bolting Installation Electrical Connection Indication 5 B -9 2 7* E N Mounting A B N Description Differential Pressure Transmitter 4 to 20 mA output with BRAIN protocol 4 to 20 mA output with HART protocol 4 to 400 in H2O 20 to 2000 in H2O 20 to 2000 psid Hastelloy C-276 diaphragm; SUS316SS flange, vent & drain 1/4" NPT on cover flange SUS630 Stainless Steel Horizontal impulse piping 1/2" NPT Female Electrical Connection, 2 connections same with SS Blind Plug LCD digital indicator with range switch Blind - No Indicator 2" mounting bracket - Carbon Steel 2" mounting bracket - Stainless Steel No bracket Example: EJA110A-DMS5B-92EA/FF1/D1/N5 — See next page for typical seal options (refer to product GS for complete model configurations) Model EJA430A Output Measurement Span (Capsule) Wetted Parts Connection Bolting Installation Electrical Connection Indication Suffix Codes -D -E A B S 5 Mounting B -9 2 7* E N A B N Description Gauge Pressure Transmitter 4 to 20 mA output with BRAIN protocol 4 to 20 mA output with HART protocol 4.3 to 430 psig 20 to 2000 psig Hastelloy C-276 diaphragm; SUS316SS flange, vent & drain 1/4" NPT on cover flange SUS630 Stainless Steel Horizontal impulse piping 1/2" NPT Female Electrical Connection, 2 connections same with SS Blind Plug LCD digital indicator with range switch Blind - No Indicator 2" mounting bracket - Carbon Steel 2" mounting bracket - Stainless Steel No bracket Example: EJA430A-DAS5B-92EA/FF1/D1/N5 — See next page for typical seal options (refer to product GS for complete model configurations) *1/2" NPT Female Electrical Connection: two connectors and a blind plug 8 ■ OPTIONAL SPECIFICATIONS (Most commonly selected for North America) Item Factory Mutual (FM) Canadian Standards Association (CSA) Lightning Protector Oil Prohibited Use Calibration Units*1 Stainless Steel Amplifier Housing*2 Body Option *4 Description FM Explosionproof Approval Explosionproof for Class I, Division 1, Groups B, C and D Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G Hazardous (classified) locations, indoors and outdoors (NEMA 4X) Temperature class: T6 Amb. Temp.: -40 to 60…C (-40 to 140…F) Electrical connection: 1/2 NPT female*1 FM Intrinsically safe Approval*3 Intrinsically Safe for Class I, Division 1, Groups A, B, C & D, Class II, Division 1, Groups E, F & G and Class III, Division 1, Hazardous Locations Nonincendive for Class I, Division 2, Groups A, B, C & D, Class II, Division 2, Groups E, F & G, and Class III, Division 1 Hazardous Locations Enclosure: "NEMA 4X", Temp. Class: T4, Amb. Temp.: -40 to 60…C (-40 to 140…F) Intrinsically Safe Apparatus Parameters (Groups A, B, C, D, E, F and G) Vmax = 30 V, Imax = 165 mA, Pmax = 0.9 W, Ci = 22.5 nF, Li = 730 H (Groups C, D, E, F and G) Vmax = 30 V, Imax = 225 mA, Pmax = 0.9 W, Ci = 22.5 nF, Li = 730 H Electrical connection: 1/2 NPT female*1 Combined FF1 and FS1*3 Electrical connection: 1/2 NPT female*1 CSA Explosionproof Approval Explosionproof for Class I, Division 1, Groups B, C and D Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G Division 2 ’SEALS NOT REQUIRED’, Temp. Class: T4, T5, T6, Encl Type 4x Max. Process Temp.: T4; 120…C (248…F), T5; 100…C (212…F), T6; 85…C (185…F) Amb. Temp.: -40 to 80…C (-40 to 176…F) Electrical connection: 1/2 NPT female*1 CSA Intrinsically safe Approval*3 Class I, Groups A, B, C and D, ClassII and III, Groups E, F and G Encl Type 4x, Temp. Class: T4, Amb. Temp.: -40 to 60…C (-40 to 140…F) Vmax = 30 V, Imax = 165 mA, Pmax = 0.9 W, Ci = 22.5 nF, Li = 730 H Electrical connection: 1/2 female*1 Combined CF1 and CS1*3 Electrical connection: 1/2 female*1 Transmitter power supply voltage: 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically safe type, 9 to 32 V DC for Fieldbus communication type) Allowable current: Max. 6000 A (1X40 s), Repeating 1000 A (1X40 s) 100 times Degrease cleansing treatment and with fluorinated oil-filled capsule Operating temperature -20 to 80…C P Calibration (psi unit) Code Amplifier housing material: SCS14A stainless steel (equivalent to SUS316 cast stainless steel or ASTM CF-8M) /E1 Assemble with low volume cover flange for remote diaphragm seal attachment /N5 *1: Applicable for electrical connection code 2 and 7. *2: Applicable for Electrical connection code 2, 3, 4, 7, 8 and 9. Not applicable for Optional code Pl and X1. *3: Applicable for output signal code D and E. *4: Do Not select this option if attaching one seal to D.P. transmitter or direct-mount on D.P., G.P. or A.P.. For intrinsically safe approval, use a safety barrier certified by the testing laboratories that corresponds with parameter limits. (BARD-400 is not acceptable.) /FF1 /FS1 /FU1 /CF1 /CS1 /CUI /A /K2 /D1 9 Extended Flanged Type Diaphragm Seals How to order Specify the model number by choosing one code from each section. Example: FLX-3012SSSNOOA05AHDP Notes 1. Direct-Mount, FXD only. 2. Use with inert fill for O2 service. 3. For wetted parts material. 4. Select for 1/4" MNPT capillary connection. EJA110/430 requires -7 installation code. Not valid for direct mount. 5. Standard capillary I.D. is 2.0mm (1.0mm for ≤10ft. capillary). Code FLX Model FXD -30 Connection Size -40 1 Flange Rating 3 6 2 Extension Length 4 6 SSS HHC Wetted, Extension SHC Diaphragm MMM TTA Always N Always 0 Always 0 A B C Fill Fluid D E G H L Direct Mount 000 Armored Capillary 05A 10A 15A 20A 25A 30A PVC Coated Capillary 05P 10P 15P 20P 25P 30P Close Coupled CCC HGP HDP Seal Connection DDP LDP DGP /S /K /M Options /C /10 /06 /V /H /P /S80 Description Note Extended Flanged Connection Direct Mount Extended Flange 3.0" Connection 4.0" Connection ANSI 150# Rating ANSI 300# Rating ANSI 600# Rating 2.0" Extension 4.0" Extension 6.0" Extension 316SS 316L Diaphragm Hastelloy C-276 Diaphragm 316SS Hastelloy Diaphragm Monel/Monel Diaphragm Tantalum/Tantalum Diaphragm Non Required Always Non Required Always Non Required Always DC200 DC704 Halocarbon (Inert) 2 Neobee M20 Glycerin 1 High Temperature Low Temperature Fluorolube (Inert Fill) 2 Direct Mount Flange (FXD only) 1 5 feet Armored Capillary 10 feet Armored Capillary 15 feet Armored Capillary 20 feet Armored Capillary 25 feet Armored Capillary 30 feet Armored Capillary 5 feet PVC Coated Capillary 10 feet PVC Coated Capillary 15 feet PVC Coated Capillary 20 feet PVC Coated Capillary 25 feet PVC Coated Capillary 30 feet PVC Coated Capillary Close Coupled Connection for use w/EJA530A/510A 1 High Side G/P High Side D/P Both Sides D/P Low Side D/P Direct G/P (for use with EJA530A/510A) Threaded EJA/capillary connection 4 Degreased 2 Mill Certification 3 Calibration/NIST Certification Smaller, 1.0mm Capillary I.D. 5 Smallest, 0.6mm Capillary I.D. 5 Vacuum Service Fill (over-fill) Helium Leak Test Certificate PFA Coated Diaphragm Schedule 80 Pipe Rating 10 Flush Flanged Type Diaphragm Seals How to order Specify the model number by choosing one code from each section. Example: FLG-301NSSSNO0A05AHDP Notes 1. Direct-Mount, FGD only. 2. Use with inert fill for O2 service. 3. For wetted parts material. 4. Select for 1/4" MNPT capillary connection. EJA110/430 requires -7 installation code. Not valid for direct mount. 5. Standard capillary I.D. is 2.0mm (0.6mm for ≤10ft. capillary). 6. Requires lower housing. 7. Not available on Tantalum or Titaniam dia. Max temp 150° C. 8. Available wetted mat l 316L SS, Hastelloy C and Tantalum only, for 2" & 3" sizes. 9. Not available with option code /SD. Code FLG Model FGD -20 Connection Size -30 -40 1 Flange Rating 3 6 Always N SSS HHC Diaphragm and SHC Upper Housing/ Wetted Housing/ STA Diaphragm SMM STI Always N 0 S Lower Housing H Material M E 0 1 Flushing Connection 2 3 4 A B C D Fill Fluid E G H L Direct Mount 000 Armored Capillary 05A 10A 15A 20A 25A 30A PVC Coated Capillary 05P 10P 15P 20P 25P 30P Close Coupled CCC HGP HDP Seal Connection DDP LDP DGP /S /K /M Options /C /10 /06 /T /SD /V /H Description Note Flush Flanged Connection Direct Mount Flush Flange 2.0" Connection 3.0" Connection 4.0" Connection ANSI 150# Rating ANSI 300# Rating ANSI 600# Rating Always 316SS/316SS/316L Diaphragm 316SS/Hastelloy C-276/Hastelloy C-276 Dia. 316SS/316SS/Hastelloy C-276 Diaphragm 316SS/Tantalum/Tantalum Diaphragm 316SS/Monel/Monel Diaphragm 316SS/Titanium/Titanium Diaphragm None-Always None 316SS Hastelloy C Monel Titanium None Single 1/4" 6 Dual 1/4" 6 Single 1/2" 6 Dual 1/2" 6 DC200 DC704 Halocarbon (Inert) 2 Neobee M20 Glycerin 1 High Temperature Low Temperature Fluorolube (Inert) 2 Direct Mount Flange (FGD only) 1 5 feet Armored Capillary 10 feet Armored Capillary 15 feet Armored Capillary 20 feet Armored Capillary 25 feet Armored Capillary 30 feet Armored Capillary 5 feet PVC Coated Capillary 10 feet PVC Coated Capillary 15 feet PVC Coated Capillary 20 feet PVC Coated Capillary 25 feet PVC Coated Capillary 30 feet PVC Coated Capillary Close Coupled Connection for use w/EJA530A/510A 1 High Side Gauge High Side D/P Both Sides D/P Low Side D/P Direct G/P (for use with EJA530A/510A) Threaded 4 Degreased 2 Mill Certification 3 Calibration/NIST Certification Smaller, 1.0mm Capillary I.D. 5 Smallest, 0.6mm Capillary I.D. 5 Teflon (PTFE) lined diaphragm 7 Step-shaped Diaphragm (>500m Bar A) 8 Vacuum Service Fill (over-fill) 9 Helium Leak Test Certificate 11 Remote Flanged Type Diaphragm Seals How to order Specify the model number by choosing one code from each section. Example: FLR-101NSSSNS0A05AHDP Notes 1. Use with inert fill for O2 service. 2. For wetted parts material. 3. Not available for flushing connection. 4. Consult factory for price if used with Hastelloy or Monel lower housing. 5. Requires lower housing. 6. Standard capillary I.D. is 2.0mm (0.6mm for ≤ 10ft. capillary). 7. Select for 1/4" MNPT capillary connection. EJA110/430 requires -7 installation code. Not valid for direct mount. 8. Titanium upper housing threaded to capillary. 9. Not available on Tantalum or Titanium diaphragm Max Temp 150°C. 10. Direct-mount only. Code FLR Model FRD -05 -10 Connection Size -15 -20 1 3 Flange Rating 6 Always N SSS HHC SHC Upper Housing/ Diaphragm STA SMM TTI Always N S H Lower Housing M Material T E 0 Flushing Connection 1 2 A B C Fill Fluid D G H L Armored Capillary 05A 10A 15A 20A 25A 30A PVC Coated Capillary 05P 10P 15P 20P 25P 30P Close Coupled CCC HGP HDP Seal Connection DDP LDP DGP /S /K /M Options /C /10 /06 /T /V /H Description Note Remote Flanged Connection Direct Mount Remote Flange 0.5" Connection 1.0" Connection 1.5" Connection 2.0" Connection ANSI 150# Rating ANSI 300# Rating ANSI 600# Rating Always 316SS/316L Diaphragm All Hastelloy 316 Upper/Hastelloy C Diaphragm 316SS/Tantalum Diaphragm 316SS/Monel 400 Diaphragm Titanium/Titanium Diaphragm 8 None-Always 316SS Hastelloy C-276 Monel Tantalum Lined 316SS 3 Titanium None Single 1/4" 4,5 Dual 1/4" 4,5 DC200 DC704 Halocarbon (Inert) 1 Neobee M20 High Temperature Low Temperature Fluorolube (Inert) 1 5 feet Armored Capillary 10 feet Armored Capillary 15 feet Armored Capillary 20 feet Armored Capillary 25 feet Armored Capillary 30 feet Armored Capillary 5 feet PVC Coated Capillary 10 feet PVC Coated Capillary 15 feet PVC Coated Capillary 20 feet PVC Coated Capillary 25 feet PVC Coated Capillary 30 feet PVC Coated Capillary Close Coupled Connection for use w/EJA530A/510A 10 High Side Gauge High Side D/P Both Sides D/P Low Side D/P Direct G/P (for use with EJA530A/510A) Threaded 7,8 Degreased 1 Mill Certification 2 Calibration/NIST Certification Smaller, 1.0mm Capillary I.D. 6 Smallest, 0.6mm Capillary I.D. 6 Teflon (PTFE) lined diaphragm 9 Vacuum Service Fill (over-fill) Helium Leak Test Certificate 12 Pancake Type Diaphragm Seals How to order Specify the model number by choosing one code from each section. Example: PNK-301NSSSNO0A05AHDP Notes 1. Use with inert fill for O2 service. 2. For wetted parts material. 3. Select for 1/4" MNPT capillary connection. EJA 110/430 requires -7 instqallation code. Not valid for direct mount. 4. Requires lower housing. 5. Standard capillary I.D. is 2.0mm (0.6mm for ≤ 10ft. capillary). 6. Not available on Tantalum or Titanium diaphragm Max Temp 150°C. 7. Available wetted mat l 316L SS, Hastelloy C and Tantalum. 8. Not available with option code /SD. Code PNK -20 Connection Size -30 0 Flange Rating 1 3 Always N SSS HHC Upper Housing/ SHC Wetted Housing/ STA Diaphragm SMM STI N Backup Flange C S 0 S Lower Housing Material H M 0 1 Connection Size 2 3 4 A B C Fill Fluid D G H L Armored Capillary 05A 10A 15A 20A 25A 30A PVC Coated Capillary 05P 10P 15P 20P 25P 30P Seal Connection HGP HDP DDP LDP DGP /S /K /M Options /C /10 /06 /T /SD /V /H Model Description Pancake Seal 2.0" Connection 3.0" Connection No Backup Flange ANSI 150# Rating ANSI 300# Rating Always 316SS/316SS/316L Diaphragm All Hastelloy 316/316SS/Hastelloy C-276 316SS/Tantalum/Tantalum 316SS/Monel/Monel 316SS/Titanium/Titanium Diaphragm None Carbon Steel Stainless Steel No Lower Housing 316SS Hastelloy C Monel None Single 1/4" Dual 1/4" Single 1/2" Dual 1/2" DC200-50 DC704 Halocarbon (Inert) Neobee M20 High Temperature (-4 to 740°F) Low Temperature (-130 to 356°F) Fluorolube (Inert) 5 feet Armored Capillary 10 feet Armored Capillary 15 feet Armored Capillary 20 feet Armored Capillary 25 feet Armored Capillary 30 feet Armored Capillary 5 feet PVC Coated Capillary 10 feet PVC Coated Capillary 15 feet PVC Coated Capillary 20 feet PVC Coated Capillary 25 feet PVC Coated Capillary 30 feet PVC Coated Capillary High Side Gauge High Side D/P Both Sides D/P Low Side D/P Direct G/P (for use with EJA530A/510A) Threaded Degreased (use w/inert fill for O2 service) Mill Certification for wetted parts material Calibration/NIST Certification Smaller, 1.0mm Capillary I.D. Smallest, 0.6mm Capillary I.D. Teflon (PTFE) lined diaphragm Step-shaped Diaphragm (>500 mBar A) Vacuum Service Fill (over-fill) Helium Leak Test Certificate Note 4 4 4 4 4 1 1 3 1 2 5 5 6 7 8 13 Sanitary Type Diaphragm Seals How to order Specify the model number by choosing one code from each section. Example: STC-20SNSSSN00D05AHDP Notes 1. Sanitary in-line only. 2. Not available on sanitary in-line. 3. For wetted parts material. 4. Direct Mount only. 5. Select for 1/4" MNPT capillary connection. EJA 110/430 requires -7 installation code. Not valid for direct mount. 6. TSP and TSD require 2.0" or 6.0" extension length selection. 7. Standard capillary I.D. is 2.0 mm (1.0mm for ≤10ft. capillary). Code STC CBI CBQ SNL TSP ASP APC Model GCH STD CID CQD TSD ASD APD GHD -TB -TC -TD -TE -TF Connection Size -TG -15 -20 -25 -30 -40 S Connection Rating F L N Extension Length 2 6 SSS Upper Housing/ Diaphragm HHC Always N 0 Tank Spud Sleeve 2 6 Always 0 D E Fill Fluid J K M Direct Mount 000 Armored Capillary 05A 10A 15A 20A 25A 30A PVC Coated Capillary 05P 10P 15P 20P 25P 30P Close Coupled CCC HGP HDP Seal Connection DDP LDP DGP /S /M /C Options /10 /06 /P /A /V /H Description Note Sanitary Tri-Clamp Cherry Burrell "I" Line Cherry Burrell "Q" Line Sanitary In-Line Tank Spud (4" only) 6 Aseptic Connection "APC" Quick Connect GC "H" Line Direct Mount Tri-Clamp Direct Mount Cherry Burrell "I" Line Direct Mount Cherry Burrell "Q" Line Direct Mount Tank Spud (4") 6 Direct Mount Aseptic Direct Mount "APC" Direct Mount GC "H" 3/4" (Sanitary In-Line only) 1 1.0" (Sanitary In-Line only) 1 1.5" (Sanitary In-Line only) 1 2.0" (Sanitary In-Line only) 1 3.0" (Sanitary In-Line only) 1 4.0" (Sanitary In-Line only) 1 1.5" Connection 2.0" Connection 2.5" Connection 2 3.0" Connection 4.0" Connection 2 Sanitary 20 RA Finish (Electro-Polish) Sanitary In-Line - 20RA Finish 1 None 2.0" Extension (TSP/TSD only) 6 6.0" Extension (TSP/TSD only) 6 316SS/316L Diaphragm All Hastelloy 2 Non required None 2" ext. Tank Spud Sleeve (TSP/TSD only) 6" ext. Tank Spud Sleeve (TSP/TSD only) No Lower Housing Neobee M20 Glycerin 4 DC200 - 350 (Food Grade) Vegetable Oil Mineral Oil Direct Mount Flange 4 5 feet Armored Capillary 10 feet Armored Capillary 15 feet Armored Capillary 20 feet Armored Capillary 25 feet Armored Capillary 30 feet Armored Capillary 5 feet PVC Coated Capillary 10 feet PVC Coated Capillary 15 feet PVC Coated Capillary 20 feet PVC Coated Capillary 25 feet PVC Coated Capillary 30 feet PVC Coated Capillary Close Coupled Connection for use w/EJA530A/510A 4 High Side Gauge High Side D/P Both Sides D/P Low Side D/P Direct G/P (for use with EJA530A/510A) Threaded 5 Mill Certification 3 Calibration/NIST Certification Smaller, 1.0mm Capillary I.D. 7 Smallest, 0.6mm Capillary I.D. 7 Tank Spud Clamp (TSP/TSD only) EPDM O-Ring (tank spud only) Vacuum Service Fill (over-fill) Helium Leak Test Certificate 14 Threaded Off-Line Type Diaphragm Seals How to order Specify the model number by choosing one code from each section. Example: THR-TCTNSSSNS0A05AHDP Notes 1. Use with inert fill for O2 service. 2. For wetted parts material. 3. Consult factory for price if used with Hastelloy on Monel lower housing. 4. Select for 1/4" MNPT capillary connection. EJA110/430 requires -7 installation code. Not valid for direct mount. 5. Requires lower housing. 6. Standard capillary I.D. is 2.0mm (1.0mm for ≤10ft. capillary). 7. Titanium upper housing threaded to capillary. 8. Not available on Tantalum or Titanium diaphragm Max Temp 150°C. 9. Direct-mount only. Code THR Model TRD -TA Connection Size -TB -TC T Flange Rating M Always N SSS HHC SHC Upper Housing/ Diaphragm STA SMM TTI Always N S H Lower Housing M E 0 1 Flushing Connection 2 5 6 A B C Fill Fluid D G H L Armored Capillary 05A 10A 15A 20A 25A 30A PVC Coated Capillary 05P 10P 15P 20P 25P Close Coupled CCC Cooling Element 4CE HGP HDP Seal Connection DDP LDP DGP /S /K /M Options /C /10 /06 /T /V /H Description Threaded Connection Direct Mount Threaded (for EJA530/510A only) 1/2" Connection 3/4" Connection 1.0" Connection Threaded NPT-F Threaded NPT-Male Non required 316SS/316L Diaphragm All Hastelloy C-276 316SS/Hastelloy Diaphragm 316S/Tantalum Diaphragm 316SS/Monel Titanium/Titanium Non required 316SS Hastelloy C-276 Monel Titanium None Single 1/4" Dual 1/4" Single 1/4" (Hastelloy C) Dual 1/4" (Hastelloy C) DC200 DC704 Halocarbon (Inert) Neobee M20 High Temperature Low Temperature Fluorolube (Inert) 5 feet Armored Capillary 10 feet Armored Capillary 15 feet Armored Capillary 20 feet Armored Capillary 25 feet Armored Capillary 30 feet Armored Capillary 5 feet PVC Coated Capillary 10 feet PVC Coated Capillary 15 feet PVC Coated Capillary 20 feet PVC Coated Capillary 25 feet PVC Coated Capillary Note Close Coupled Connection for use w/EJA530A/510A 9 9 4" Cooling Element, 316SS (typical 200+°F dissipation) High Side Gauge High Side D/P Both Sides D/P Low Side D/P Direct G/P (for use with EJA530A/510A) Threaded Degreased Mill Certification Calibration/NIST Certification Smaller, 1.0mm Capillary I.D. Smallest, 0.6mm Capillary I.D. Teflon (PTFE) Lined Diaphragm Vacuum Service Fill (over-fill) Helium Leak Test Certificate 7 5 5 3, 5 3, 5 1 1 4,7 1 2 6 6 8 15 Low-Range Type Diaphragm Seals How to order Specify the model number by choosing one code from each section. Example: FBD-20TNSSSNS0A05AHDP Notes 1. Direct mount only. 2. Use with inert fill for O2 service. 3. Requires lower housing. 4. Select for 1/4" MNPT capillary connection. EJA110/430 requires -7 installation code. Not valid for direct mount. 5. Standard capillary I.D. is 2.0mm (1.0mm for ≤10ft. capillary). 6. For flanges connection only. 7. Not available on Tantalum or Titanium diaphragm Max Temp 150°C. Code FBD FBR FBT -TA -TB -TC -TD -TE -05 Connection Size -07 -10 -15 -20 -30 -40 T M Flange Rating 1 3 6 Always N SSS HHC SHC Upper Housing/ WettedDiaphragm STA SMM STI Always N S M Lower Housing H Material T E 0 1 Flushing Connection 2 3 4 A B C D Fill Fluid E G H L Direct Mount 000 Armored Capillary 05A 10A 15A 20A 25A 30A PVC Coated Capillary 05P 10P 15P 20P 25P 30P Close Coupled CCC Seal Connection HGP HDP DDP LDP DGP /S /K /M /C Options /10 /06 /T /V /H Model Description Flanged Direct Mount Remote Flange Remote Flange Threaded 1/2" (FBT) 3/4" (FBT) 1.0" (FBT) 1.5" (FBT) 2.0" (FBT) 1/2" (FBR) 3/4" (FBR) 1.0" (FBD, FBR) 1.5" (FBD, FBR) 2.0" (FBD, FBR) 3.0" (FBD, FBR) 4.0" (FBD, FBR) Threaded NPT-F Threaded NPT-Male ANSI 150# ANSI 300# ANSI 600# Always 316SS/316L Diaphragm All Hastelloy 316 Upper/Hastelloy C Diaphragm 316SS/Tantalum Diaphragm 316SS/Monel 400 Diaphragm Titanium/Titanium Diaphragm Non required 316SS Hastelloy C Monel Tantalum Plated 316SS Titanium None Single 1/4" Dual 1/4" Single 1/2" Dual 1/2" DC200 DC704 Halocarbon (Inert) Neobee M20 Glycerin High Temperature Low Temperature Fluorolube (Inert) Direct Mount (FBD only) 5 feet Armored Capillary 10 feet Armored Capillary 15 feet Armored Capillary 20 feet Armored Capillary 25 feet Armored Capillary 30 feet Armored Capillary 5 feet PVC Coated Capillary 10 feet PVC Coated Capillary 15 feet PVC Coated Capillary 20 feet PVC Coated Capillary 25 feet PVC Coated Capillary 30 feet PVC Coated Capillary Close Coupled Connection for use w/EJA530/510A High Side Gauge High Side D/P Both Sides D/P Low Side D/P Direct G/P (for use with EJA530A/510A) Threaded Degreased Mill Certification Calibration/NIST Certification Smaller, 1.0mm Capillary I.D. Smallest, 0.6mm Capillary I.D. Teflon (PTFE) lined diaphragm Vacuum Service Fill (over-fill) Helium Leak Test Certificate Note 6 3 3 3 3 2 1 2 1 1 4 2 5 5 7 16 Saddle Type Diaphragm Seals How to order Specify the model number by choosing one code from each section. Example: SDL-08NNSSSSNNA05AHDP 1. Select for 1/4" MNPT connection. Transmitter requires -7 installation code. Not valid for direct mount. 2. Use with Inert Fill for O2 service. 3. For wetted parts material. 4. Standard capillary I.D. is 2.0mm (1.0mm for ≤ 10ft. capillary). 5. Direct-mount only. Description Remote Saddle Saddle Close Coupled (EJA 510/530) -NA WIKA retrofit (existing saddle) -03 3.0" (normal pipe size) -04 4.0" (normal pipe size) Connection Size -06 6.0" (normal pipe size) -08 8.0" (normal pipe size) -10 10.0" (normal pipe size) -12 12.0" (normal pipe size) Connection Rating N 1500PSI Always N None SSS 316SS/316L Diaphragm SHC 316SS/Hastelloy C Diaphragm Upper Housing/ Diaphragm STA 316SS/Tantalum Diaphragm SMM 316SS/Monel 400 Assembly Hardware S Stainless Steel N None C Carbon Steel, Nickel Plated Lower Housing Material S 316SS H Hastelloy C-276 Always N None A DC200 B DC704 C Halocarbon (Inert) Fill Fluid D Neobee M20 G High Temperature H Low Temperature L Fluorolube (Inert) Armored Capillary 05A 5 feet Armored Capillary 10A 10 feet Armored Capillary 15A 15 feet Armored Capillary 20A 20 feet Armored Capillary 25A 25 feet Armored Capillary 30A 30 feet Armored Capillary PVC Coated Capillary 05P 5 feet PVC Coated Capillary 10P 10 feet PVC Coated Capillary 15P 15 feet PVC Coated Capillary 20P 20 feet PVC Coated Capillary 25P 25 feet PVC Coated Capillary 30P 30 feet PVC Coated Capillary Close Coupled CCC Close Coupled Connection for use w/EJA530/510A HGP High Side Gauge HDP High Side D/P Seal Connection DDP Both Sides D/P LDP Low Side D/P DGP Close Couples (for use with EJA530A/510A) /S Threaded /K Degreased /M Mill Certification Options /10 Smaller, 1.0mm Capillary I.D. /06 Smallest, 0.6mm Capillary I.D. /T Teflon (PTFE) lined diaphragm /C Calibration/NIST Certification /V Vacuum Service Fill (over-fill) /H Helium Leak Test Certificate Model Code SDL SDD Note 2 2 5 1 2 3 4 4 17 Extended Flanged Type Diaphragm Seals Size 3" 4" Flange Rating A 150# 7.48 300# 8.27 150# 9.06 300# 10.04 B 6.01 6.63 7.5 7.87 C 5.0 5.0 6.22 6.22 D 2.99 2.99 3.7 3.7 E 2.83 2.83 3.5 3.5 F 0.94 1.14 0.94 1.26 G 0.06 0.06 0.06 0.06 2 L 4 6 2 4 6 Flush Flanged Style Diaphragm Seals Size 2" 3" 4" Flange Rating 150# 300# 600# 150# 300# 600# 150# 300# 600# A 5.9 6.5 B 4.74 5.0 7.48 8.27 6.0 6.63 9.06 10.04 10.83 7.5 7.87 8.5 C D 3.62 2.32 5.0 E 0.77 0.89 1.26 0.94 1.14 1.51 0.94 1.26 2.00 3.5 6.22 3.5 F 0.625 G 0.79 0.25 0.625 0.25 0.625 0.25 0.79 0.91 0.79 0.91 1.02 Remote Flange Type Diaphragm Seals G2 Process D1 H G3 Weight 150# 4.25 1.66 4x1/2" – 13 UNC 4.4lbs. 300# 3.74 4.88 1.79 4x1/2" – 11 UNC 8.5lbs. 150# 5.00 1.7 4x3/4" – 13 UNC 6.9lbs. 1.5" 300# 3.74 6.12 3" 600# 1" Pressure Rating D 600# 4x3/4" – 10 UNC 2.1 10.8lbs. 11.5lbs. Pancake Style Diaphragm Seal Size Pressure A B C D E 2" 3" 150 to 2500 4 2.32 0.78 4 0.629 150 to 2500 5.28 3.50 0.78 4 0.629 18 Threaded Off-Line Diaphragm Seals Sanitary Tri-Clamp Diaphragm Seals Size G2 Process Connection D 1/2" 3/4" 1" 3.74 Weight A C D E 1.5" 1.33lbs. 1.5 1.71 1.97 1.38 H 2" 1.67lbs. 1.5 2.22 2.52 1.38 1.18 2.2 3" 2.00lbs. 2.52 2.78 3.05 1.38 1.41 2.36 1.77 3.46 D1 Tank Spud Diaphragm Seals 19 Saddle Diaphragm Seals Connection C 1/4” or 1/2” NPT female Radius R in mm 1.49 38 1.77 45 2.24 57 2.76 70 3.35 85 4.31 109.5 5.37 136.5 6.38 162 7.0 177.8 To Fit Pipe Size in mm 2.5 65 3.0 80 100 4.0 5.0 125 6.0 150 8.0 200 10.0 250 12.0 300 14.0 350 Pipe Outer Diameter in mm 3.00 76.1 3.50 88.9 4.50 114.3 5.5 139.7 6.63 168.3 8.63 219.1 10.75 273.0 12.75 323.8 14.75 374.6 20 Printed in USA 01/04 IMP FIBU 0017