General product information:
The Safety Manager System is a microprocessor based safety system which is used for various plant
process controls. The overall system is mounted in a steel cabinet with a tool secured door.
This system is of modular design consisting of a power supply system with the voltage ranges of 94 – 253
Vac (50/60Hz) that includes power supply units (PSUs) that generates 24 Volts dc supplies; main switches,
power distribution rails, controller chassis with QPPs, communication modules, 5V supply modules,
input/output chassis with all input/output modules and field termination assemblies and /or terminals and the
Ethernet switch for communications within the system. All these are assembled inside the tool secured IP64
rated steel enclosure.
The SK 3340.024, SK 3341.024, SK 3350.024 and SK 3351.024 Fan Assemblies manufactured by Rittal and
installed in Honeywell Safety Manager systems are designed for industrial process control applications.
These Fan Assemblies Series are suitable for supply voltages of 24 Vdc with current of up to 0.75A. The fan
units are classified as Pollution Degree 2 and Overvoltage Category II. The units operate at an ambient
temperature range of -10 °C to +55° C and are assessed together with the cabinets. The fans are installed
inside the cabinet.
The certification ratings of the Power Supply Unit (PSU) and the Ethernet switch are listed below.
Item
Component
Certificate No.
Certificate Coding
Ex nA nC IIC T4
FA-PSU-UNI2450U IECEx LCI 10.0031U
Ta = -40°C to 50°C (Full Output Current)
Power
Ta = -40°C to 70°C (Half Output Current)
Supply Unit
EDS-305, EDS-316
Ex nA nL nC IIC T4
Ethernet
IECEx UL 11.0034X
Ta = -40°C to 75°C
Switch
(-T Model)
The modules covered by this report are listed below;
Module Type
Module Description
FC-QPP-0001
FC-QPP-0002
FS-CPCHAS-0001
FC-USI-0001
FC-BKM-0001
FC-PSU-240516
FC-IOCHAS0001R
FC-IOCHAS0001S
FC-IO-0001
FC-SDI-1624
FC-BSDI-16UNI
Quad Processor Pack (Confomal Coated)
Quad Processor Pack (Confomal Coated)
Safety Manager Controller chassis
Universal Safety Interface (Confomal Coated)
Battery and Keyswitch Module (Confomal Coated)
Power Supply Unit 24/5 Vdc, 16A (Confomal Coated)
Safety Manager I/O chassis Redundant
FC-SAI-1620m
FC-SDIL-1608
FC-BN-1608
FC-BSN-1608
FC-SDO-0824
FC-SAO-0220m
FC-SDOL-0424
Safety Manager I/O chassis Single
I/O extender module (Confomal Coated)
Fail-safe digital input module (24 Vdc, 16 channels) (Confomal Coated)
Adapter module for normally open digital inputs with ELD function
(16 channels) (Confomal Coated)
Fail-safe high-density analog input module (24 Vdc, 16 channels) (Confomal
Coated)
Fail-safe line-monitored digital input module with earth fault monitor
(16 channels) (Conformal Coated)
NAMUR sensor converter module for SDIL-1608 (16 channels) (Confomal Coated)
Fail-safe 'NAMUR' sensor converter module for SDIL-1608 (16 channels)
(Confomal Coated)
Fail-safe digital output module (24 Vdc, 0.55 A, 8 channels) (Confomal Coated)
Fail-safe analog output module (0(4)-20 mA, 2 channels) (Confomal Coated)
Fail-safe loop-monitored digital output module (24 Vdc, 1 A, 4 ch.) (Confomal
Coated)
Page 1 of 2
Annex 1 to GB/FME/ExTR12.0008 Issue No. 00
Module Type
Module Description
FC-BSDOL-04UNI
FC-TERM-0002
FC-TERM-0001
FS-IOB-0001S
FS-IOB-0001R
10306/1/1
10310/1/1
FC-TSAO-0220m
FC-TSDO-04UNI
FC-TSDO-0824
FC-TSAI-1620m
FC-TSAIOP1620m
FC-TSHRTOP1620m
FC-TPSU-2430
FC-TSFIRE-1624
Set of range-setting modules for SDOL (4 channels) (Confomal Coated)
Bus terminator for redundant I/O (Confomal Coated)
Bus terminator for non-redundant I/O (Confomal Coated)
I/O backplane for non-redundant I/O, part of FC-IOCHAS-0001S
I/O backplane for redundant I/O, part of FC-IOCHAS-0001R
Supply Input Filters (24 Vdc)
Earth leakage detector (ELD)
Fail-safe analog output FTA (0(4)-20 mA, 2 channels) (Confomal Coated)
Fail-safe digital output FTA (24/48/60/110 Vdc, 4 channels) (Confomal Coated)
Fail-safe digital output FTA (24 Vdc, 8 channels) (Confomal Coated)
Fail-safe 0(4)-20 mA analog input FTA (16 channels) (Confomal Coated)
Fail-safe 0(4)-20 mA analog input FTA 24 Vdc (16 channels) (Confomal Coated)
FC-TSDI-16UNI
FC-TSDI-1624
FC-TSDI-1624C
FC-TSDO-0824C
FC-TSDOL-0424C
FC-TSHART1620m
FC-TSGAS-1624
FC-IOBUS-HBS
FC-IOBUS-HBR
FS-CPB-0001
FC-DCOM-232/385
FC-PDB-0824P
PDB-IOX05
PDB-CPX05
FS-EOL-485-01
FS-MB-0001
FS-MB-0002
FS-MB-0003
Fail-safe 0(4)-20 mA analog input FTA 24 Vdc with HART interface (16 channels)
(Confomal Coated)
24 Vdc to 30 Vdc/1 A converter (Confomal Coated)
Fail-safe Fire detector input FTA with line monitoring (24 Vdc, 16 ch.) (Confomal
Coated)
Fail-safe digital input FTA (24/48/60 Vdc, NAMUR, 16 channels) (Confomal Coated)
Safe digital input FTA (24Vdc, 16 channels)
Current-limited digital input FTA (24 Vdc, 16 channels) (Confomal Coated)
Fail-safe current limited output FTA (24 Vdc, 8 channels) (Confomal Coated)
Fail-safe current limited output FTA (24 Vdc, 4 channels) (Confomal Coated)
Fail-safe 0(4)-20 mA analog input FTA with HART interface (16 ch.) (Confomal
Coated)
Fail-safe Gas –Flame detector input FTA (0 – 20 mA, 16 channels) (Confomal
Coated)
Horizontal non-redundant I/O bus backplane, part of FC-IOCHAS-0001S
(Conformal Coated)
Horizontal redundant I/O bus backplane, part of FC-IOCHAS-0001R (Conformal
Coated)
Control processor backplane, part of FC-CPCHAS-0001
Communication interface FTA for RS232 and RS485 (Conformal Coated)
Power Distribution Board, 24 Vdc, 8 Channels (Conformal Coated)
Power Distribution Board extension IO cabinet (5 Vdc, Watchdog)
Power Distribution Board Controller cabinet (5 Vdc, Watchdog)
RS485 End-of-line connector (metal housing)
Power busbar max.200A 24/48/110Vdc,150cm
Power busbar max.200A 24/48/110Vdc, 60cm
Power busbar max.200A 24/48/110Vdc, 90cm