S4 Series - Assured Automation

advertisement
1-800-899-0553
assuredautomation.com
S4 Series
Multi-voltage Reversible Electric Actuator
The S4 Series is a 1/4 turn multi-voltage electric
valve actuator which incorporates the latest
advances in motor and control technology at an
economical price.
S4 SERIES
MODEL NUMBERING
The S4 unit incorporates automatic voltage sensing
and allows for AC or DC supply within each voltage
range. The electronic torque limiter protects the
actuator and the LED status lights allow for easier
field diagnostics. The domed position indicator
provides a visual indication of valve position. The
DIN wiring connections allow the unit to be field
wired without opening the actuator.
Output Torque:
0170 = 170 in-lbs
0300 = 300 in-lbs
0480 = 480 in-lbs
0750 = 750 in-lbs
1200 = 1200 in-lbs
2600 = 2600 in-lbs
Options include a plug-and-play analog to digital
positioner and a battery “spring return” feature
that allows the actuator to fail closed or fail open in
the event of a power failure.
FEATURES
• Multi-voltage
Low: (MV1) 12 to 24vAC/DC
(sizes 1200 & 2600 are 24vAC/DC)
High: (MV2) 85 to 240vAC/DC
• Internal thermostat controlled anti-condensation
heater.
• Isolated end of travel limit switches.
• Manual override for emergency hand operation.
• Electronic torque limiter.
• Auto-voltage sensing reduces field wiring mistakes.
Model Number:
Voltage:
MV1 = 12 to 24 VAC/VDC
(sizes 1200 & 2600 24 VAC/VDC)
MV2 = 85 to 240 VAC/VDC
Optional:
(installed in actuator)
EP420 = 4-20m ADC positioner
EP010 = 0-10 VDC
Battery Failsafe
BSRC = Fail Closed
BSRO = Fail Open
Accessories:
DC = 15’ cord set DIN connectors
DN = 1/2” NPT connectors
TEMPERATURE RANGE
-4˚F to 158˚F.
• Visual domed position indicator.
SPECIFICATIONS
• LED status indicator.
Duty Rating:
75%.
• IP67 enclosure S40170 to S40750,
IP65 S41200 and S42600.
• External wiring connection with DIN Plugs,
no need to open unit for field wiring.
• ISO5211 mounting flange.
S4 X X X X
Rotation:
90˚ standard.
Limit Switch:
2 isolated End of Travel.
• CE Marked.
Heater:
3.5 W.
OPTIONAL FEATURES
Plugs:
DIN 43650, ISO 440, C192.
• DPS analog to digital positioner
(4-20m ADC and 0-10 VDC).
• BSR battery failsafe (fail closed or fail open).
• Potentionmeter: 1K, 5K,10K.
• 3 position stop.
• Cord sets or NPT DIN connectors.
S42013. Contact us for the most recent product and technical information. Visit our website for more details: assuredautomation.com
IP Rating:
IP67 (S40170 to S40750)
IP65 (S41200 and S42600).
Insulation:
Class B.
1
1-800-899-0553
assuredautomation.com
S4 Series
Multi-voltage reversible electric actuator
(12 to 24 VAC/VDC and 85 to 240 VAC/VDC)
Manual override
handwheel
0170 & 0300
Mounting Dimensions
LED status indicator
(trouble shooting)
Visual position
indicator
Position feedback
(isolated contacts)
Power supply
connector
A1
G
H (sq.)
0480 & Larger
Mounting Dimensions
A2
G
G
H (sq.)
0480
&
Larger
C
G
D
B
E
G
Automatic/manual
control lever
F
DIMENSIONS, WEIGHTS & SPECIFICATIONS
Output Torque (in/lb)
Run
Start
177
309
486
752
1239
2655
221
353
540
796
1504
3097
Speed (sec.)
A1
A2
B
C
D
E
F
G
H
(sq. mm)
12 to 24 V
85 to 240 V
6.73
6.73
-
7.72
7.72
10.00
10.00
6.97
6.97
6.97
6.97
9.25
9.25
4.96
4.96
4.96
4.96
5.04
5.04
2.01
2.01
2.01
2.01
4.21
4.21
2.16
2.16
2.16
2.85
4.21
4.21
2.16
2.16
2.16
2.16
4.21
4.21
F03/04/05
F03/04/05
F05/07
F05/07
F07/F10
F07/F10
14 x 14
14 x 14
17 x 17
17 x 17
22 x 22
22 x 22
12
12
16
35
33
60
11
11
14
40
33
60
1
ADDITIONAL SPECIFICATIONS
Mounting/Shaft:
ISO 5211/Female.
Indicator and Internal Cams:
Glass-filled polyamide.
4.0
4.2
5.3
6.6
11.4
11.5
S40170MV 1
S40300MV 1
S40480MV 1
S40750MV 1
S41200MV 1
S42600MV 1
Voltage: 1 = 12 to 24 VAC/VDC; 2 = 85 to 240 VAC/VDC.
Pattern
BC
Holes
F03
F04
F05
F07
F10
1.42
1.65
1.97
2.76
4.02
4 x M5
4 x M5
4 x M6
4 x M8
4 x M10
Body and Cover:
Anticorrosive polyamide.
Gears:
Steel and polyamide.
Model No.
MOUNTING PATTERN SPECIFICATIONS
MATERIALS OF CONSTRUCTION
Main External Shaft and Fastenings:
Stainless steel.
Wt. (lbs.)
CURRENT DRAW (AMPS)
Model No.
S40170MV_
S40300MV_
S40480MV_
S40750MV_
S41200MV_
S42600MV_
MV1
MV2
12 VDC
24 VDC
24 VAC
115 VAC
240 V/1ph
2.1
3.0
3.1
2.6
N/A
N/A
1.0
1.5
1.6
1.2
3.0
3.0
0.9
1.1
1.3
1.0
3.6
3.6
0.2
0.3
0.3
0.2
0.7
0.7
0.1
0.2
0.2
0.1
0.3
0.3
S42013. Contact us for the most recent product and technical information. Visit our website for more details: assuredautomation.com
2
1-800-899-0553
assuredautomation.com
S4 Series
Multi-voltage reversible electric actuator
(12 to 24 VAC/VDC and 85 to 240 VAC/VDC)
FUNCTION: ON/OFF VERSION
WIRING DIAGRAM (ON/OFF OR FAILSAFE ACTUATORS)
• Power open, power close.
END OF TRAVEL
CONFIRMATION
POWER SUPPLY
CAN BE EITHER 3 OR 2 WIRE
• Stays in position on power failure.
3 WIRE SYSTEM
2 WIRE SYSTEM
FUNCTION: FAILSAFE VERSION
• Power open, power close. Trickle charges battery in either
open or closed position.
POWER
CONNECTION
2
• Actuator driven by battery power to preset failsafe position on
power failure.
• Actuator returns to pre-failure position on power resumption.
• Failsafe can be either NC (normally closed) or NO
(normally open).
E
1
ISOLATED DRY
CONTACT
CONNECTION
E
POWER
CONNECTION
2
1
3
2
1
3
3
Customer
to supply
Customer
to supply
OPEN
CLOSE
OPEN
CLOSE
S
FUNCTION: MODULATING VERSION
S
L or +
• Power open, power close. Actuator movement controlled
by input signal (4-20mA or 0-10VDC).
• Standard operation: 4mA or 0V = actuator closed,
20mA OR 10V = actuator open (can be reversed).
AC (1ph) or
DC SUPPLY
C
S = CHANGE-OVER SWITCH
To supply continuous signal
until end of travel is reached.
+
e.g.: Lights on
a control panel
–
DC SUPPLY
N or –
S = REVERSING POLARITY SWITCH
To supply continuous signal
until end of travel is reached.
O
ISOLATED DRY CONTACTS
Factory set at 0˚ and 90˚
Switches rated 220V 5A
ANTI-CONDENSATION HEATER
Operates only while power is on. Power can be left on permanently.
• Standard operation: actuator closes on loss of control signal,
stays put if loss on main power.
• Ouput signal provided as standard (in same format as
supply signal).
or
WIRING DIAGRAM (MODULATING ACTUATORS)
ADDITIONAL NOTES (ALL VERSIONS)
POWER
SUPPLY
4-20mA or 0-10VDC
CONTROL SIGNALS
INPUT AND OUTPUT
• Actuator power supply must be on a dedicated circuit and
must be grounded.
END OF TRAVEL
CONFIRMATION
Input and Output – ve
Customer
to supply
• Isolated dry contact switches are set approximately 5˚ ahead of
the final motor stop position. Do not use the signal from the
isolated dry contact switches to cut the power to the motor,
otherwise the actuator will not reach the full open or full
closed position. The actuator is designed to have continuously
energized power.
Output 4-20mA/0-10V + ve
E
2
Customer
to supply
Input 4-20mA/0-10V + ve
3
1
1
2
2
1
3
3
Customer
to supply
Customer
to supply
L or +
AC (1ph) or
DC SUPPLY
N or –
C
O
+
e.g.: Lights on
a control panel
–
ISOLATED DRY CONTACTS
Factory set at 0˚ and 90˚
Switches rated 220V 5A
S42013. Contact us for the most recent product and technical information. Visit our website for more details: assuredautomation.com
3
1-800-899-0553
assuredautomation.com
S4 Series
Multi-voltage reversible electric actuator
(12 to 24 VAC/VDC and 85 to 240 VAC/VDC)
S4 LED STATUS INDICATOR
Constantly Lit LED:
If the actuator is operating correctly with no faults, the LED shows a constantly lit light.
LED Flashes with Two Blinks:
If the actuator has been left in “manual” mode, the actuator’s motor runs but doesn’t drive the
output shaft. After a preset time, the actuator knows that as the torque limiter has not activated
and that the motor is running, it must be in manual.
LED Flashes On/Off:
When the actuator senses an inpending valve jam, the electronic torque limiter is activated, and on
activation, repeatedly flashes the LED on and off.
ACCESSORIES
Electronic Positioner:
The DPS is a microprocessor based electronic positioner that takes an analog input (4-20mADC or
0-10VDC) and provides an analog output (4-20mADC or 0-10VDC). The positioner is self-calibrating
upon start up or after the valve is positioned manually. The DPS circuit is continuously monitoring
the input and output signals and the physical position. Digital control insures high sensitivity and
repeatability. The positioner can be installed in the field.
Battery Failsafe:
The BSR option is a battery “spring return” capability that allows
the actuator to fail open or fail closed upon loss of power. This
option is significantly smaller and cost competitive when compared
to mechanical spring return electric actuators. The battery is
constantly charging so it has maximum capacity when needed.
It provides the power to close or open the valve a few times upon
loss of power. If you plan to use the actuator to replace a
solenoid; energize to open, fail close, you will have to allow a
short period to charge the battery back to maximum power
between cycles. A positioner can be installed with the BSR option.
Optional DIN Connectors:
DIN connectors are available with a 15’ cordset or with 1/2” NPT
conduit entry.
S42013. Contact us for the most recent product and technical information. Visit our website for more details: assuredautomation.com
4