CMS Combustion Management System

advertisement
Combustion Made Simple
Exhibition Launch
CMS Combustion Management System
Sensors and systems for combustion engineering
www.lamtec.de
LAMTEC | CMS Combustion Management System
Combustion Management System –
the evolution of Combustion Management
Whether it’s standard industrial combustion or complex process applications, LAMTEC’s revolutionary
new CMS Burner Management System sets new
standards in control automation.
Modular: The CMS is simple and easily configured to
meet a wide and varied range of application requirements from small industrial burners to large complex
systems; everything is controllable. The CMS can control up to 10 three-point step outputs, 60 failsafe digital inputs and 41 failsafe digital outputs. Modules
can be located anywhere over a 100 m increasing design flexibility.
MCC
 Power supply 24 VDC
 12 failsafe digital inputs
 9 failsafe digital outputs
 Ethernet with MODBUS TCP
 CODESYS Soft-SPS integrated
 Available in 5 versions:
Input 24 VDC / Output 24 VDC
Input 24 VDC / Output 120 VDC
Input 24 VDC / Output 230 VDC
Input 120 VDC / Output 120 VDC
Input 230 VDC / Output 230 VDC
AEC-TPS
 2 Outputs: Open/Close for servo motors
 Compatible with DPS motors
 Position feedback via potentiometer
5 kΩ
 2 Versions: 120 VAC and 230 VAC
 5 AEC-TPS module per system maximum*
AEC-VS
 4 ... 20 mA output for frequency inverter
 Alternatively 4 ... 20 mA output for
positioning
 Feedback NAMUR, 3-wire sensor
or 4 ... 20 mA
 digital output for “FAN On”
 Digital input for “Frequency inverter,
fault/ready”
 10 AEC-VS modules per system maximum*
2
Safety: Modules are connected via a failsafe iLSB. The
LAMTEC CMS has all the relevant standards approvals
for industrial and process combustion applications (in preparation) including: EN298, EN12067-2, EN1643, UL, CSA,
AGA, Marine approval GL, SIL3 according to EN61508.
Communications: The CMS has an Ethernet interface and
uses MODBUS TCP as standard. Additional field bus communications such as PROFINET, PROFIBUS and MODBUS
RTU are also supported. The CMS provides communications via Webserver allowing fast access to information.
The CMS is compatible with the current LAMTEC SYSTEM
BUS (LSB) and so can seamlessly integrate with existing
systems.
Simple: At LAMTEC, CMS stands for ‘Combustion Made
Simple’, underling the intuitive graphic-based user inter-
SDI
 8 Failsafe digital inputs
 3 Versions: 24 VDC, 120 VAC, 230 VAC
 6 SDI modules per system maximum
SDO
 8 Failsafe digital outputs
 2 A per output maximum
 3 Versions: 24 VDC, 120 VAC, 230 VAC
 4 SDO modules per system maximum
SAI
 4 Failsafe inputs or 4 ... 20 mA, Pt100,
Pt1000
 2 pulsed inputs for fuel meter
 2 SAI modules per system maximum
Bus Motor
 To drive actuators & control valves
directly via LSB
 Approved for electronic ratio control
* Depends on the simultaneous usage of AEC-TPS and AEC-VS.
A maximum number of 10 actuators are possible.
face. The CMS interface is an evolution of the BT300
operating philosophy. Working with the CMS is intuitive
and easy to learn for everyone; no special training is
required.
Customisable: The standard graphic user interfaces are
the simple UI400 and the 7” GUI607 colour touchscreen.
However, the CMS is very flexible with HMIs and both 10”
(GUI610) and 15” (GUI15) colour touchscreens are also
available for delivery. Furthermore, it is possible to connect additional HMIs to allow control at different site
locations. This feature is also available when using OEM
HMI solutions.
individual application requirements. Single fuel, dual
fuel and additional fuel can all be supported; safety
chains or individual interlocks can be assigned. In
addition spare I/O can be assigned for use with the
on-board CODESYS PLC.
Versatile: Are there any non-failsafe control requirements associated with the system? The CMS utilises
an integrated CODESYS Soft-SPS which provides PLC
functionality using spare I/O or additional I/O modules. This powerful feature enables users to customise their CMS systems and HMI touchscreens to meet
customer requirements in ways not available until
now.
Flexibility: Inputs and outputs from the burner system
can be freely assigned to the CMS modules. This feature
enables users to design and configure the CMS to their
UI400
 Low Cost HMI
 Graphical user interface
 Display, language neutral
 Easy operation
 Connection via LAMTEC SYSTEM BUS
(LSB)
 Distance to the MCC up to 500 m
GUI607
 7” Touchscreen
 Other sizes available as options
(10” GUI610, 15” GUI615)
 Graphical user interface
 Mostly language neutral
 Plant graphic
 Graphic is adaptable to customer
specifications
 Setup assistant
 Distance to MCC is unlimited (Ethernet)
PC Software
 Software for configuration
 Connection to CMS via Ethernet
 Printing of the wiring diagram
 Checklist for equipment test
 Parameter checking towards standards
Soft-SPS
 Individual configuration of not failsafe
functions
 Integrated in MCC and GUI
 CODESYS Standard software
CO/O2-Control
 LAMTEC CO/O2 Control connected via
LSB
 Compatible with Lambda Transmitter
LT3-F as well as LT1 and LT2
Flame detector
 FFS07 /FFS08 are interfaced directly to
MCC
 Connection of F130I, F152, F200K,
F300K via safe digital inputs
 Connection of future flame detectors
via failsafe iLSB bus
www.lamtec.de
3
LAMTEC | CMS Combustion Management System
Applications Comparison.
Comparison between.
Present LAMTEC System
Versions: CMS Combustion Management System
=
<
+
UI400
Burner Control FA1 with customer interface
=
<
UI400
<
GUI607
<
MCC
Advantages over ETAMATIC/
ETAMATIC S:
 7“ Touchscreen with graphical
user interface
 Field bus on board
 Optimal usage of inputs
and outputs through free
allocation of functions
 Expandable
+
2x AEC-TPS AEC-VS
MCC
+ +
GUI607
FMS4/FMS5
Advantages over ETAMATIC OEM:
 Simple graphical user
interface
 Field bus on board
 Optimal usage of inputs
and outputs through free
allocation of functions
 Expandable
2x AEC-TPS
MCC
+ +
=
=
MCC
+ +
ETAMATIC OEM with customer interface
ETAMATIC/ETAMATIC S
Advantages over FA1:
 Space-saving
 Field bus on board
 Optimal usage of inputs
and outputs through free
allocation of functions
Advantages over FMS4/FMS5:
 Optimal usage of inputs
and outputs through free
allocation of functions
 7“ Touchscreen with
graphical user interface
 CODESYS Soft-SPS for
non-failsafe functions
 Additional functions
 Expandable
+ + +
2x AEC-TPS AEC-VS
SDO
SDI
LAMTEC CMS offers unlimited possibilities.
Maximum possibilities with CMS Combustion
Management System
The full version of the LAMTEC CMS offers far more operational possibilities than present LAMTEC systems. For
example, it is possible to connect multiple HMIs such as
the UI400, GUI607 or alternative panels. The I/O expansion modules allow large complex systems to be configured; up to 60 failsafe digital inputs and 41 failsafe digi-
+ +
GUI607
MCC
tal outputs are available. A maximum of 10 output drives
can be connected and configured; they are flexible and
can include DPS three-point step servomotors, frequency inverters, 4 ... 20 mA positioners or bus motors. Up to
12 analogue inputs for sensors to monitor and control
temperatures, pressures. Feed forward control can be
included in systems as well as inputs to monitor pulsed
outputs from steam and fuel flow meters etc .
+ +
4x AEC-TPS*
2x AEC-VS*
+
6x SDI
+
4x SDO
2x SAI
* Depends on the simultaneous usage of AEC-TPS and AEC-VS. A maximum number of 10 actuators is possible.
LAMTEC Meß- und Regeltechnik
für Feuerungen GmbH & Co. KG
Wiesenstraße 6
D-69190 Walldorf
Telephone: +49 (0) 6227 6052-0
Fax:
+49 (0) 6227 6052-57
LAMTEC Leipzig
GmbH & Co. KG
Portitzer Straße 69
D-04425 Taucha
Telephone: +49 (0) 34298 4875-0 info@lamtec.de
Fax:
+49 (0) 34298 4875-99 www.lamtec.de
Druckschrift-Nr. DLT7016-15-aEN-001
Subject to change I Printed in Germany I Copyright © 2015 LAMTEC