RIDGE ® Project Details: Ridge Squared Project Details: with Parabolic Linero, (2)Louver 32W T8, 28W T5 41 average(2)footcandles, 34 average footcandles .88w/sq. ft. .48 w/sq. ft. Spectrum Engineers www.pinnacle-ltg.com The Ridge by Pinnacle Architectural Lighting is a fully modular suspended and wall linear product line that bridges a full line of lamping and light control capabilities with a narrow profile to provide tremendous high efficiency, low glare performance for the widest range of commercial applications. RIDGE 5 With a 5-1/2” profile, Ridge 5 provides a narrower profile to the Ridge 9 series. Ridge 5 offers a slender satine acrylic lens, T5 and T8 lamping configurations and a daylight sensor for projects with strict energy requirements. Ridge Squared 5 (RS5A) 1T5, 2T5, 3T5 5-1/2” 2-7/8" 5-1/2” 2-7/8" 1T8, 2T8 1T5 1T8 www.pinnacle-ltg.com Ridge 5 (R5A) 1T5, 2T5, 3T5 5-3/4” 1T8, 2T8 1T5 2-7/8" 5-3/4” 2-7/8" Ridge 5 Components 48.0" 4' Ridge 5 Components Ridge 5 Components 96.0" 8' 48.0" 144.0" 4' 12' 96.0" Add 1/8" for each end plate or 1/4" to the overall length of the row. 8' 144.0" 12' Add 1/8" for each end plate or 1/4" to the overall length of the row. Ridge 5 Mounting Options Ridge 9 Components 48.0" 4' 96.0" Ridge 9 Components 8' Single Aircraft Cable 48.0" 4' 8' Single aircraft cable allows for adjustment from side to side and horizontal96.0" leveling. 12' 144.0" 12' Add 1/8" for each end plate or 1/4" to the overall length of the row. Wall 144.0" Wall mount easily mounts to structure and allows for lateral adjustment of Add 1/8" for each end plate or 1/4" to the overall length of the row. fixture. 1T8 RIDGE 9 Ridge 9 is our slightly wider companion to the Ridge 5. This larger profile allows for more versatility. Along with more T8 lamping configurations, Ridge 9 offers more controlled light solutions, both louver and satine lens shielding features and additional mounting options . Ridge Squared 9 Lens (RS9A) 1T5, 2T5, 3T5 8-1/2" 1T8, 2T8, 3T81 1T5, 2T5 1T8, 2T8 2-7/8" 8-1/2" 2-7/8" Ridge Squared 9 Louver (RS9P) 1T5, 2T5, 3T5 8-1/2" 2-7/8" 8-1/2" 2-7/8" 1T8, 2T8, 3T81 1T5, 2T5 1T8, 2T8 www.pinnacle-ltg.com Ridge 9 Lens (R9A) 1T5, 2T5, 3T5 8-1/2" 1T8, 2T8, 3T8 1T5, 2T51 1T8, 2T8 2-7/8" 9" 2-7/8" Ridge 5 Components 48.0" 4' Ridge 9 Louver (R9P) 8' 8-1/2" 96.0" 1T5, 2T5, 3T5 1T8, 2T8, 3T8 144.0" 1T5, 2T51 12' 2-7/8" Add 1/8" for each end plate or 1/4" to the overall length of the row. 9" 2-7/8" Ridge 9 Components Ridge 9 Components 48.0" 4' 96.0" 8' 144.0" 12' Add 1/8" for each end plate or 1/4" to the overall length of the row. Ridge 9 Mounting Options Single Aircraft Cable Pendant Pipe Wall Single aircraft cable allows for adjustment from side to side and horizontal leveling. Fixture wires are fed through rigid stem pendants allowing for a cleaner installation. Wall mount easily mounts to structure and allows for lateral adjustment of fixture. 1 T8, 2T8 LIGHT DISTRIBUTION OPTIONS Ridge offers multiple distribution options allowing you to customize the lighting to your project’s requirement. Light Distribution kits easily install over the lamps and are available from 60% downlight up to 100% downlight. Available on both the Ridge and Ridge Squared parabolic louver housing styles. Standard Distribution: DL60: DL80: 70% Indirect 40% Indirect 20% Indirect 10% Indirect 0% Indirect 30% Direct 60% Direct 80% Direct 90% Direct 100% Direct LAMP BARRIERS Direct Lighting Lamps on Lamps Off DL90: DL100: Isolate uplight and downlight using lamp barriers. Utilize with dual circuit switching for the ultimate in light control. Lamp barriers are the perfect solution for projects with multiple lighting requirements. Available with Ridge and Ridge Squared with parabolic louver. Indirect Lighting Direct Lighting For Lamps DirectonLighting, out-Off Lamps OffLamps Lamps on the side lamps are turned on for general purpose lighting. Indirect Lighting Lamps on Lamps Off Indirect Lighting allows occupants to easily take notes while still viewing presentations. www.pinnacle-ltg.com Project Details: Ridge Squared with Parabolic Louver (2) 28W T5 34 average footcandles .48 w/sq. ft. Reduce overall energy usage Turnkey solution Today’s building environments require thoughtful choices from planning through final integration. Taking advantage of daylight harvesting potential to save energy and create smarter, more responsible environments is easily achieved through the use of the integrated daylight sensor option for Ridge. In addition to inherent green benefits, the integrated daylight sensor is a turnkey solution with no extra control wires to the fixture. Easily specified with Technical fixtures and by simply following the recommended best practices in regards to placement of the daylight sensor, you can add daylight harvesting to your - Controls up to 20 dimming ballasts project’s list of energy saving green potential. - +1.5v to +10.5v input control to ballast - Sensor adjustable from 1/3 to 3x light output Sensor Setup Technical Sensor Placement - Controls up to 20 dimming ballasts - +1.5v to +10.5v input control to ballast - Sensor adjustable from 1/3 to 3x light output No additional commissioning is The sensor location placement in Ridge fixtures allows for easy placeSensor Placement required. To adjust light levels in ment of the sensor in beinglocation daylighted. spaces that require more or lessrelation to the space The sensor placementHousings in Ridge fixtures fluorescent light, be simply rotate the can also rotated allows for easy placement of the sensor in relation sensor aperture in the fixture. to the space being daylighted. Housings can also for even more flexibility. be rotated for even more flexibility. Ease of Installation Ease of Installation Contractors will appreciate the minimal extra wiring needed for Ridge fixtures with the daylight sensor option. have no additional Contractors will appreciate the Fixtures minimal will extra wiring needed forcontrol wiring feed; runthe mounting simply require an additional Ridgecontinuous fixtures with daylightwill sensor option. Fixtures will havepair of wires joined between fixtures. no additional control wiring feed; continuous run mounting will simply require an additional pair of wires joined between fixtures. - 8' 12' Rotate the aperture clockwise for less fixture light Rotate the aperture counter clockwise for more fixture light + Individual 4' Default factory preset for 45fc at work surface Standard sensor placement shown for 4', 8' and 12' fixtures Additional wire pair for Continuous Row Continuous Row Energy Savings Help reduce overall energy usage on a project and contribute to the sustainability of the building with easily achieved energy savings. Depending on location and season, savings can be as significant as 15-45% annually. Design Placement While the daylight sensor is flexible and easy to specify, some guidelines for sensor placement within yourDesign project or space should be followed to Placement maximize daylight harvesting potential. While the daylight sensor is flexible and easy to specify, some guidelines for sensor placement within your project or space should be followed to maximize daylight harvesting potential. 1 3 4 2 5 Follow these guidelines for optimal results: Typical Sensor 1 Sensor should be within 6'-10' from windows 2 Typical daylighting zone from windows is 15' 3 Sensors should not be placed within 5' of each other 4 Sensor should be placed over typical work area 5 Recommended mounting height for sensor is 8'-10' www.pinnacle-ltg.com DAYLIGHT HARVESTING MOUNTING Aircraft Cable to Grid Ceiling (AC_G_) 5-3/4” Utilize with on-grid mounting with acoustical grid ceiling Power Side ed Lamp Options T8 2T5, 2T8 Non-Power Side 2-7/8" (AC_JB) Aircraft Cable to Structure (AC_ST) Utilize with sheet rock and off grid acoustical grid ceiling Utilize for inaccessible hard ceiling Power Side Power Side Aircraft Cable to Junction Box Non-Power Side Non-Power Side Wall Lamp Options 3T5 1T5 Box Pendant Pipe to Junction (PP_JB) Ridge 9 only 1T8 Pendant Pipe to Structure (PP_ ST) Ridge 9 only Utilize with sheet rock and off grid acoustical grid ceiling Utilize for inaccessible hard ceiling Power Side Power Side Non-Power Side Non-Power Side Corners Ridge and Ridge Squared corners are available in three different configurations for endless possibilities in layout design. CL = 90 Degree Corner CT = T Connector JOINING AND WIRING Ridge luminaires are joined using Pinnacle’s key hole alignment system.The locking mechanism simplifies installation by allowing the fixture installer to hang one fixture onto the next making installation nearly a one-man operation. CX == X Connector Connector Secure fixtures together by aligning screws into key-holes Project Details: Ridge Squared with Satine Lens (2) 28W T5 35 average footcandles 1.0 w/sq. ft. DCS Design Make wire connections using supplied push nuts. Tighten screws until fixtures are joined together. Fixtures joined and aligned. APPLICATION GUIDELINES 60’ x 60’x 9’ Room Application Guidelines Work Area: Ridge 5 Satine Lens, 1T5 With Specular Reflector Ridge 9 Parablic Louver, 2T8 14 ft 48’ Rows 14’ on center 31.7 fc 40.0 fc 22.0 fc Power Density (W/sq. ft.): 0.42 Row Length: Row Spacing: Light Level (fc): Maximum: Minimum: 40’ x 40’ Fixture Drop: 48’ Rows Row Length: on center Row Spacing:Light Level18’ (fc): 47.2 fc Maximum: 70.0 fc Minimum: Power Density (W/sq. ft.):20.0 fc 0.59 18 ft 735 910 551 368 184 683 456 228 (1) 28W T5 Efficiency: 92% Direct: 15%; Indirect: 85% 80/50/20 reflectance Light Loss Factor .85 (2) 32W T8 Efficiency: 87% Direct: 35%; Indirect: 65% 80/50/20 reflectance Light Loss Factor .75 30’ x 30’x 9’ Room Application Guidelines Work Area: Ridge 5 Satine Lens, 1T5HO With Specular Reflector Ridge 9 Parablic Louver, 2T8 14 ft 20’ Rows Row Length: Row Spacing: 14’ on center Light Level (fc): 41.5 fc 59.0 fc Maximum: 23.0 fc Minimum: Power Density (W/sq. ft.): 0.68 20’ x 20’ 14 ft Fixture Drop: 910 950 633 317 683 456 228 80/50/20 reflectance Light Loss Factor .75 (1) 54W T5HO Efficiency: 92% Direct: 15%; Indirect: 85% (2) 32W T8 Efficiency: 87% Direct: 35%; Indirect: 65% 10’ x 15’x 9’ Room Application Guidelines Work Area: Ridge 5 Satine Lens, 2T8 With Specular Reflector Ridge 9 Parablic Louver, 2T8 6’ x 11’-5” Fixture Drop: 1215 910 911 607 304 683 456 228 80/50/20 reflectance Light Loss Factor .75 (2) 32W T8 Efficiency: 85% Direct: 15%; Indirect: 85% 18” 8’ Rows Row Length: Light Level (fc): 39.3 fc Maximum:48.0 fc 30.0 fc Minimum: 0.78 Power Density (W/sq. ft.): 8’ Row Row Length: Light Level (fc): 30.3 fc Maximum: 41.0 fc 20.0 fc Minimum: 0.78 Power Density (W/sq. ft.): 80/50/20 reflectance Light Loss Factor .75 18” Row Length: 16’ Rows Row Spacing:14’ on center Light Level (fc):38.2 fc Maximum: 61.0 fc Minimum: 14.0 fc Power Density (W/sq. ft.): 0.52 1266 80/50/20 reflectance Light Loss Factor .85 18” (2) 32W T8 Efficiency: 87% Direct: 35%; Indirect: 65% www.pinnacle-ltg.com LUMINAIRE SPECIFICATION Ridge Squared 5 and Ridge 5 PRO DU CT LAMPS RS5A-Ridge Squared 5, Satine Lens 1T52T53T51T5HOR5A-Ridge 5, 2T5HOParabolic Louver 3T5HO1T82T8- (1) 28W T5 (2) 28W T5 (3) 28W T5 (1) 54W T5HO (2) 54W T5HO (3) 54W T5HO (1) 32W T8 (2) 32W T8 LENGTH MOUNTING Individual Units 44’ 88’ 12- 12’1 Continuous Runs xx’- Specify nomincal overall row length in 4’ increments Aircraft Cable AC48G1- 1” T-Bar AC48G9- 9/16” T-Bar AC48GS- Slotted T-Bar AC48JB- Junction Box AC48ST- Structure AC548G_- 5” Non-Power Canopy2 AC548JB- 5” Non-Power Canopy2 SQ48G_- 5” Square Canopy2 SG548JB- 5” Square Canopy2 V OLTAGE 120- 120 V 277- 277 V 347- 347 V3 UNV- UNV3 (120-277) C IR C UITING FINIS H 1C- Single Circuit 2C- Dual Circuit3 1D- Single Circuit Dimming3 2D- Dual Circuit Dimming3 1E- Single Circuit with Emergency Circuit3 2E- Dual Circuit with Emergency Circuit3 1B- Single Circuit with Battery Pack3 2B- Dual Circuit with Battery Pack3 W- Matte White S- Metallic Silver BL- Textured Black BR- Bronze CC- Custom Color OPT IO N S DSMDSSMSQSDGSRCLCXCTCC-C- Daylight Sensor Master5 Daylight Sensor Satelitle5 Motion Sensor Quick Ship6 Dust Guard Spectular Reflector4 90° Corner X Connector (AC Cable) T Connector (AC Cable) Custom Color Canopy Wall Mount1 WAWall Mount 12 ft is not available on wall mounted fixtures. Replaces standard 2” non-power canopy. Square canopy replaces standard round. Must specify grid ceiling type on AC548G_ and SQ48G_. Select from G1 (1” grid), G9 (9/16” grid), or GS (slotted); for example AC548G1. 3 Some Ridge configurations will not accommodate all electrical options. Consult factory. Some Rigde options are not available for all housing styles. Seee specification sheet. Sensor included on all DSM fixtures. Sensor not included on DSS fixtures. See specification sheet for information regarging sensor placement, set-up and ordering details. 6 Quick Ship included universal voltage, standard white finish and single (1C) and Dual (2C) circuit. 1 4 2 5 Specifications and dimensions subject to change without notice. Marketing information on pinnacle-letg.com is the most recent version and supersedes all previouslyt printed or electronic versions. Ridge Squared 9 and Ridge 9 PRO DU CT RS9A-Ridge Squared 9, Satine Lens LAMPS 1T52T53T51T5HORS9P-Ridge 2T5HOSquared 9, 3T5HOParabolic Louver 1T82T8R9A-Ridge 9, 3T8Satine Lens R9A-Ridge 9, Parabolic Louver (1) 28W T5 (2) 28W T5 (3) 28W T5 (1) 54W T5HO (2) 54W T5HO (3) 54W T5HO (1) 32W T8 (2) 32W T8 (3) 32W T8 LENGTH MOUNTING Individual Units 4’ 488’ 12- 12’1 Continuous Runs xx’- Specify nomincal overall row length in 4’ increments Aircraft Cable AC48G1- 1” T-Bar AC48G9- 9/16” T-Bar AC48GS- Slotted T-Bar AC48JB- Junction Box AC48ST- Structure AC548G_- 5” Non-Power Canopy2 AC548JB- 5” Non-Power Canopy2 SQ48G_- 5” Square Canopy2 SG548JB- 5” Square Canopy2 Pendant Pipe8 PP__JB- Junction Box7 PP__ST- Structure7 V OLTAGE 120- 120 V 277- 277 V 347- 347 V UNV- UNV (120-277) C IR C UITING 1C- Single Circuit 2C- Dual Circuit3 1D- Single Circuit Dimming3 2D- Dual Circuit Dimming3 1E- Single Circuit with Emergency Circuit3 2E- Dual Circuit with Emergency Circuit3 1B- Single Circuit with Battery Pack3 2B- Dual Circuit with Battery Pack3 FINIS H W- Matte White S- Metallic Silver BL- Textured Black BR- Bronze CC- Custom Color OPT IO N S DSMDSSMSDL100DL90DL80DL60QSLB1LB2DGSRLO CLCXCTCC-C- Daylight Sensor Master5 Daylight Sensor Satelitle5 Motion Sensor 100% Direct 90% Direct/ 10% Indirect4 80% Direct/ 20% Indirect4 60% Direct/ 40% Indirect4 Quick Ship6 2 Lamps Up/ 1 Down4 2 Lamps Down4 Dust Guard Spectular Reflector4 Lens Overlay4 90° Corner X Connector (AC Cable) T Connector (AC Cable) Custom Color Canopy Wall Mount1 Wall Mount WA- 12 ft is not available on wall mounted fixtures. Replaces standard 2” non-power canopy. Square canopy replaces standard round. Must specify grid ceiling type on AC548G_ and SQ48G_. Select from G1 (1” grid), G9 (9/16” grid), or GS (slotted); for example AC548G1. 3 Some Ridge configurations will not accommodate all electrical options. Consult factory. 4 Some Rigde options are not available for all housing styles. Seee specification sheet. 1 2 5 Sensor included on all DSM fixtures. Sensor not included on DSS fixtures. See specification sheet for information regarging sensor placement, set-up and ordering details. 6 Quick Ship included universal voltage, standard white finish and single (1C) and Dual (2C) circuit. 7 Specify overall length of pendant, 12”, 18”, or 24”. Consult factory for additional lengths. 8 Pendant mounting not available with 4ft, T8 fixture. Specifications and dimensions subject to change without notice. Marketing information on pinnacle-letg.com is the most recent version and supersedes all previouslyt printed or electronic versions. ® 12655 East 42nd Avenue Suite 50 Denver CO, 80239 Phone: 303.322.5570 Fax: 303.322.5568 www.pinnacle-ltg.com October 2014 © 2014 Pinnacle Architectural Lighting ®