RIDGE
®
Project Details:
Ridge
Squared
Project
Details:
with Parabolic
Linero, (2)Louver
32W T8,
28W T5
41 average(2)footcandles,
34 average footcandles
.88w/sq. ft.
.48 w/sq. ft.
Spectrum Engineers
www.pinnacle-ltg.com
The Ridge by Pinnacle Architectural Lighting is a fully modular suspended and wall
linear product line that bridges a full line of lamping and light control capabilities
with a narrow profile to provide tremendous high efficiency, low glare performance
for the widest range of commercial applications.
RIDGE 5
With a 5-1/2” profile, Ridge 5 provides a narrower profile to the Ridge 9 series. Ridge 5 offers a slender satine
acrylic lens, T5 and T8 lamping configurations and a daylight sensor for projects with strict energy requirements.
Ridge Squared 5 (RS5A)
1T5, 2T5, 3T5
5-1/2”
2-7/8"
5-1/2”
2-7/8"
1T8, 2T8
1T5
1T8
www.pinnacle-ltg.com
Ridge 5 (R5A)
1T5, 2T5, 3T5
5-3/4”
1T8, 2T8
1T5
2-7/8"
5-3/4”
2-7/8"
Ridge 5 Components
48.0"
4'
Ridge
5 Components
Ridge
5 Components
96.0"
8'
48.0"
144.0"
4'
12'
96.0"
Add 1/8" for each end plate or 1/4" to the overall length of the row.
8'
144.0"
12'
Add 1/8" for each end plate or 1/4" to the overall length of the row.
Ridge 5 Mounting Options
Ridge 9 Components
48.0"
4'
96.0"
Ridge 9 Components
8'
Single Aircraft Cable
48.0"
4'
8'
Single aircraft cable allows
for adjustment from side to
side and horizontal96.0"
leveling.
12'
144.0"
12'
Add 1/8" for each end plate or 1/4" to the overall length of the row.
Wall
144.0"
Wall mount easily mounts
to structure and allows
for lateral adjustment of
Add 1/8" for each end plate or 1/4" to the overall length of the row.
fixture.
1T8
RIDGE 9
Ridge 9 is our slightly wider companion to the Ridge 5. This larger profile
allows for more versatility. Along with more T8 lamping configurations,
Ridge 9 offers more controlled light solutions, both louver and satine
lens shielding features and additional mounting options .
Ridge Squared 9 Lens (RS9A)
1T5, 2T5, 3T5
8-1/2"
1T8, 2T8, 3T81
1T5, 2T5
1T8, 2T8
2-7/8"
8-1/2"
2-7/8"
Ridge Squared 9 Louver (RS9P)
1T5, 2T5, 3T5
8-1/2"
2-7/8"
8-1/2"
2-7/8"
1T8, 2T8, 3T81
1T5, 2T5
1T8, 2T8
www.pinnacle-ltg.com
Ridge 9 Lens (R9A)
1T5, 2T5, 3T5
8-1/2"
1T8, 2T8, 3T8
1T5, 2T51
1T8, 2T8
2-7/8"
9"
2-7/8"
Ridge 5 Components
48.0"
4'
Ridge 9 Louver (R9P)
8'
8-1/2"
96.0"
1T5, 2T5, 3T5
1T8, 2T8, 3T8
144.0"
1T5, 2T51
12'
2-7/8"
Add 1/8" for each end plate or 1/4" to the overall length of the row.
9"
2-7/8"
Ridge 9 Components
Ridge 9 Components
48.0"
4'
96.0"
8'
144.0"
12'
Add 1/8" for each end plate or 1/4" to the overall length of the row.
Ridge 9 Mounting Options
Single Aircraft Cable
Pendant Pipe
Wall
Single aircraft cable
allows for adjustment
from side to side and
horizontal leveling.
Fixture wires are fed
through rigid
stem pendants
allowing for
a cleaner
installation.
Wall mount easily
mounts to structure
and allows for
lateral adjustment of
fixture.
1 T8, 2T8
LIGHT DISTRIBUTION
OPTIONS
Ridge offers multiple distribution options allowing you to customize the lighting to
your project’s requirement. Light Distribution kits easily install over the lamps and
are available from 60% downlight up to 100% downlight. Available on both the
Ridge and Ridge Squared parabolic louver housing styles.
Standard Distribution:
DL60:
DL80:
70% Indirect
40% Indirect
20% Indirect
10% Indirect
0% Indirect
30% Direct
60% Direct
80% Direct
90% Direct
100% Direct
LAMP
BARRIERS
Direct Lighting
Lamps on
Lamps Off
DL90:
DL100:
Isolate uplight and downlight using lamp barriers. Utilize with dual circuit switching for the ultimate in light control. Lamp
barriers are the perfect solution for projects with multiple
lighting requirements. Available with Ridge and Ridge Squared with parabolic
louver.
Indirect Lighting
Direct Lighting
For Lamps
DirectonLighting,
out-Off
Lamps
OffLamps
Lamps
on the
side lamps are turned on for
general purpose lighting.
Indirect Lighting
Lamps on
Lamps Off
Indirect Lighting allows occupants to
easily take notes while still viewing
presentations.
www.pinnacle-ltg.com
Project Details:
Ridge Squared with
Parabolic Louver
(2) 28W T5
34 average footcandles
.48 w/sq. ft.
Reduce
overall
energy
usage
Turnkey
solution
Today’s building environments require thoughtful choices from planning through final integration. Taking advantage of daylight harvesting potential to save
energy and create smarter, more responsible environments is easily achieved through the use of the integrated daylight sensor option for Ridge.
In addition to inherent green benefits, the integrated daylight sensor is a turnkey solution with no extra control wires to the fixture. Easily specified with
Technical
fixtures and by simply following the recommended best practices in regards to placement of the daylight sensor, you can add daylight harvesting to your
- Controls up to 20 dimming ballasts
project’s list of energy saving green potential.
- +1.5v to +10.5v input control to ballast
- Sensor adjustable from 1/3 to 3x light output
Sensor Setup
Technical
Sensor Placement
- Controls up to 20 dimming ballasts
- +1.5v to +10.5v input control to ballast
- Sensor adjustable from 1/3 to 3x light output
No additional
commissioning
is
The sensor
location placement
in Ridge
fixtures
allows for easy placeSensor
Placement
required. To adjust light levels in
ment
of
the
sensor
in
beinglocation
daylighted.
spaces that require more or lessrelation to the space
The sensor
placementHousings
in Ridge fixtures
fluorescent
light, be
simply
rotate the
can also
rotated
allows for easy placement of the sensor in relation
sensor aperture in the fixture.
to the space being daylighted. Housings can also
for even more flexibility.
be rotated for even more flexibility.
Ease of Installation
Ease of Installation
Contractors
will appreciate the minimal extra wiring needed for Ridge fixtures
with
the
daylight
sensor option.
have
no additional
Contractors will appreciate
the Fixtures
minimal will
extra
wiring
needed forcontrol wiring
feed;
runthe
mounting
simply
require
an additional
Ridgecontinuous
fixtures with
daylightwill
sensor
option.
Fixtures
will havepair of wires
joined
between
fixtures.
no additional control wiring feed; continuous run mounting will
simply require an additional pair of wires joined between fixtures.
-
8'
12'
Rotate the aperture
clockwise for
less fixture light
Rotate the aperture
counter clockwise
for more fixture light
+
Individual
4'
Default factory
preset for 45fc at
work surface
Standard sensor placement
shown for 4', 8' and 12' fixtures
Additional wire pair
for Continuous Row
Continuous Row
Energy Savings
Help reduce overall energy usage on a project and contribute to the sustainability
of the building with easily achieved energy savings. Depending on location and
season, savings can be as significant as 15-45% annually.
Design Placement
While the daylight sensor is flexible and easy to
specify, some guidelines for sensor placement
within yourDesign
project
or space should be followed to
Placement
maximize daylight harvesting potential.
While the daylight sensor is flexible and easy to
specify, some guidelines for sensor placement
within your project or space should be followed to
maximize daylight harvesting potential.
1
3
4
2
5
Follow these guidelines for optimal results:
Typical Sensor
1
Sensor should be within 6'-10' from windows
2
Typical daylighting zone from windows is 15'
3
Sensors should not be placed within 5' of each other
4
Sensor should be placed over typical work area
5
Recommended mounting height for sensor is 8'-10'
www.pinnacle-ltg.com
DAYLIGHT HARVESTING
MOUNTING
Aircraft Cable to Grid Ceiling (AC_G_)
5-3/4”
Utilize with on-grid mounting with acoustical grid
ceiling
Power Side
ed Lamp Options
T8
2T5, 2T8
Non-Power Side
2-7/8"
(AC_JB)
Aircraft Cable to Structure
(AC_ST)
Utilize with sheet rock and off grid acoustical
grid ceiling
Utilize for inaccessible hard
ceiling
Power Side
Power Side
Aircraft Cable to Junction Box
Non-Power Side
Non-Power Side
Wall Lamp Options
3T5
1T5 Box
Pendant
Pipe to Junction
(PP_JB) Ridge 9 only
1T8
Pendant Pipe to Structure (PP_
ST) Ridge 9 only
Utilize with sheet rock and off grid acoustical grid
ceiling
Utilize for inaccessible hard ceiling
Power Side
Power Side
Non-Power Side
Non-Power Side
Corners
Ridge and Ridge Squared corners are available in
three different configurations for endless possibilities in layout design.
CL =
90 Degree
Corner
CT =
T Connector
JOINING AND
WIRING
Ridge luminaires are joined using
Pinnacle’s key hole alignment system.The locking
mechanism simplifies installation by allowing the
fixture installer to hang one fixture onto the next
making installation nearly a one-man operation.
CX ==
X Connector
Connector
Secure fixtures together by
aligning screws into key-holes
Project Details:
Ridge Squared with Satine Lens
(2) 28W T5
35 average footcandles
1.0 w/sq. ft.
DCS Design
Make wire connections using
supplied push nuts.
Tighten screws until fixtures
are joined together.
Fixtures joined
and aligned.
APPLICATION GUIDELINES
60’ x 60’x 9’ Room Application Guidelines
Work Area:
Ridge 5 Satine Lens, 1T5 With Specular Reflector
Ridge 9 Parablic Louver, 2T8
14 ft
48’ Rows
14’ on center
31.7 fc
40.0 fc
22.0 fc
Power Density (W/sq. ft.): 0.42
Row Length:
Row Spacing:
Light Level (fc):
Maximum:
Minimum:
40’ x 40’
Fixture Drop:
48’ Rows
Row Length:
on center
Row Spacing:Light Level18’
(fc):
47.2 fc
Maximum:
70.0 fc
Minimum:
Power Density (W/sq. ft.):20.0 fc
0.59
18 ft
735
910
551
368
184
683
456
228
(1) 28W T5
Efficiency: 92%
Direct: 15%; Indirect: 85%
80/50/20 reflectance
Light Loss Factor .85
(2) 32W T8
Efficiency: 87%
Direct: 35%; Indirect: 65%
80/50/20 reflectance
Light Loss Factor .75
30’ x 30’x 9’ Room Application Guidelines
Work Area:
Ridge 5 Satine Lens, 1T5HO With Specular Reflector
Ridge 9 Parablic Louver, 2T8
14 ft
20’ Rows
Row Length:
Row Spacing: 14’ on center
Light Level (fc): 41.5 fc
59.0 fc
Maximum:
23.0 fc
Minimum:
Power Density (W/sq. ft.): 0.68
20’ x 20’
14 ft
Fixture Drop:
910
950
633
317
683
456
228
80/50/20 reflectance
Light Loss Factor .75
(1) 54W T5HO
Efficiency: 92%
Direct: 15%; Indirect: 85%
(2) 32W T8
Efficiency: 87%
Direct: 35%; Indirect: 65%
10’ x 15’x 9’ Room Application Guidelines
Work Area:
Ridge 5 Satine Lens, 2T8 With Specular Reflector
Ridge 9 Parablic Louver, 2T8
6’ x 11’-5”
Fixture Drop:
1215
910
911
607
304
683
456
228
80/50/20 reflectance
Light Loss Factor .75
(2) 32W T8
Efficiency: 85%
Direct: 15%; Indirect: 85%
18”
8’ Rows
Row Length:
Light Level (fc): 39.3 fc
Maximum:48.0 fc
30.0 fc
Minimum:
0.78
Power Density (W/sq. ft.):
8’ Row
Row Length:
Light Level (fc): 30.3 fc
Maximum: 41.0 fc
20.0 fc
Minimum:
0.78
Power Density (W/sq. ft.):
80/50/20 reflectance
Light Loss Factor .75
18”
Row Length:
16’ Rows
Row Spacing:14’ on center
Light Level (fc):38.2 fc
Maximum:
61.0 fc
Minimum:
14.0 fc
Power Density (W/sq. ft.): 0.52
1266
80/50/20 reflectance
Light Loss Factor .85
18”
(2) 32W T8
Efficiency: 87%
Direct: 35%; Indirect: 65%
www.pinnacle-ltg.com
LUMINAIRE SPECIFICATION
Ridge Squared 5 and Ridge 5
PRO DU CT
LAMPS
RS5A-Ridge
Squared 5,
Satine Lens
1T52T53T51T5HOR5A-Ridge 5,
2T5HOParabolic Louver 3T5HO1T82T8-
(1) 28W T5
(2) 28W T5
(3) 28W T5
(1) 54W T5HO
(2) 54W T5HO
(3) 54W T5HO
(1) 32W T8
(2) 32W T8
LENGTH
MOUNTING
Individual Units
44’
88’
12- 12’1
Continuous Runs
xx’- Specify
nomincal
overall row
length in 4’
increments
Aircraft Cable
AC48G1- 1” T-Bar
AC48G9- 9/16” T-Bar
AC48GS- Slotted T-Bar
AC48JB- Junction Box
AC48ST- Structure
AC548G_- 5” Non-Power
Canopy2
AC548JB- 5” Non-Power
Canopy2
SQ48G_- 5” Square
Canopy2
SG548JB- 5” Square
Canopy2
V OLTAGE
120- 120 V
277- 277 V
347- 347 V3
UNV- UNV3
(120-277)
C IR C UITING
FINIS H
1C- Single Circuit
2C- Dual Circuit3
1D- Single Circuit
Dimming3
2D- Dual Circuit
Dimming3
1E- Single Circuit with
Emergency Circuit3
2E- Dual Circuit with
Emergency Circuit3
1B- Single Circuit with
Battery Pack3
2B- Dual Circuit with
Battery Pack3
W- Matte
White
S- Metallic
Silver
BL- Textured
Black
BR- Bronze
CC- Custom
Color
OPT IO N S
DSMDSSMSQSDGSRCLCXCTCC-C-
Daylight Sensor Master5
Daylight Sensor Satelitle5
Motion Sensor
Quick Ship6
Dust Guard
Spectular Reflector4
90° Corner
X Connector (AC Cable)
T Connector (AC Cable)
Custom Color Canopy
Wall Mount1
WAWall Mount
12 ft is not available on wall mounted fixtures.
Replaces standard 2” non-power canopy. Square canopy replaces standard round. Must specify
grid ceiling type on AC548G_ and SQ48G_. Select from G1 (1” grid), G9 (9/16” grid), or GS
(slotted); for example AC548G1.
3
Some Ridge configurations will not accommodate all electrical options. Consult factory.
Some Rigde options are not available for all housing styles. Seee specification sheet.
Sensor included on all DSM fixtures. Sensor not included on DSS fixtures. See specification
sheet for information regarging sensor placement, set-up and ordering details.
6
Quick Ship included universal voltage, standard white finish and single (1C) and Dual (2C)
circuit.
1
4
2
5
Specifications and dimensions subject to change without notice. Marketing information on pinnacle-letg.com is the most recent version and supersedes all previouslyt printed or electronic versions.
Ridge Squared 9 and Ridge 9
PRO DU CT
RS9A-Ridge
Squared 9,
Satine Lens
LAMPS
1T52T53T51T5HORS9P-Ridge
2T5HOSquared 9,
3T5HOParabolic Louver 1T82T8R9A-Ridge 9,
3T8Satine Lens
R9A-Ridge 9,
Parabolic Louver
(1) 28W T5
(2) 28W T5
(3) 28W T5
(1) 54W T5HO
(2) 54W T5HO
(3) 54W T5HO
(1) 32W T8
(2) 32W T8
(3) 32W T8
LENGTH
MOUNTING
Individual Units
4’
488’
12- 12’1
Continuous Runs
xx’- Specify
nomincal
overall row
length in 4’
increments
Aircraft Cable
AC48G1- 1” T-Bar
AC48G9- 9/16” T-Bar
AC48GS- Slotted T-Bar
AC48JB- Junction Box
AC48ST- Structure
AC548G_- 5” Non-Power
Canopy2
AC548JB- 5” Non-Power
Canopy2
SQ48G_- 5” Square
Canopy2
SG548JB- 5” Square
Canopy2
Pendant Pipe8
PP__JB- Junction Box7
PP__ST- Structure7
V OLTAGE
120- 120 V
277- 277 V
347- 347 V
UNV- UNV
(120-277)
C IR C UITING
1C- Single Circuit
2C- Dual Circuit3
1D- Single Circuit
Dimming3
2D- Dual Circuit
Dimming3
1E- Single Circuit with
Emergency Circuit3
2E- Dual Circuit with
Emergency Circuit3
1B- Single Circuit with
Battery Pack3
2B- Dual Circuit with
Battery Pack3
FINIS H
W- Matte
White
S- Metallic
Silver
BL- Textured
Black
BR- Bronze
CC- Custom
Color
OPT IO N S
DSMDSSMSDL100DL90DL80DL60QSLB1LB2DGSRLO
CLCXCTCC-C-
Daylight Sensor Master5
Daylight Sensor Satelitle5
Motion Sensor
100% Direct
90% Direct/ 10% Indirect4
80% Direct/ 20% Indirect4
60% Direct/ 40% Indirect4
Quick Ship6
2 Lamps Up/ 1 Down4
2 Lamps Down4
Dust Guard
Spectular Reflector4
Lens Overlay4
90° Corner
X Connector (AC Cable)
T Connector (AC Cable)
Custom Color Canopy
Wall Mount1
Wall Mount
WA-
12 ft is not available on wall mounted fixtures.
Replaces standard 2” non-power canopy. Square canopy replaces standard round. Must specify
grid ceiling type on AC548G_ and SQ48G_. Select from G1 (1” grid), G9 (9/16” grid), or GS
(slotted); for example AC548G1.
3
Some Ridge configurations will not accommodate all electrical options. Consult factory.
4
Some Rigde options are not available for all housing styles. Seee specification sheet.
1
2
5
Sensor included on all DSM fixtures. Sensor not included on DSS fixtures. See specification
sheet for information regarging sensor placement, set-up and ordering details.
6
Quick Ship included universal voltage, standard white finish and single (1C) and Dual (2C)
circuit.
7
Specify overall length of pendant, 12”, 18”, or 24”. Consult factory for additional lengths.
8
Pendant mounting not available with 4ft, T8 fixture.
Specifications and dimensions subject to change without notice. Marketing information on pinnacle-letg.com is the most recent version and supersedes all previouslyt printed or electronic versions.
®
12655 East 42nd Avenue Suite 50
Denver CO, 80239
Phone: 303.322.5570
Fax: 303.322.5568
www.pinnacle-ltg.com
October 2014
© 2014 Pinnacle Architectural Lighting ®
Download