Technical Specification
General
Output Signal
Detection Method
Gases Detected
Display
Control Action
Setting
Performance
: Electrochemical
: Oxygen / Toxic Gases
(Please select from the table below).
: 0.5”, 3½ digit LCD Display.
: Two independent set points, LO & HI with blinking
indication with programmable Latch & Non-latch
` facility only for indication purpose. (There is not relay
output)
: 1)By 3/4 keys on front panel i.e. ‘SET/NEXT’,
‘UP’, ‘DOWN’ & ‘TEST/BACK’.
2) By using Magnetic pen (only for Flameproof model)
Start-up Time
Error Monitoring
1) By Display :
Environmental
Accessories
: 24 VDC, Range 14-36 VDC, 25mA
Power Supply
Power Consumption : Less than 0.6 Watts.
: 2 wires (1.5mm2), Flexible OR Armoured shielded
Connection
cable
CE certified 24 VDC Power supply.
Canopy Mounting stand.
Gas Calibration Kit.
Flameproof Housing
Protection Class
Weatherproof Housing
:
:
:
:
:
:
Sensor Break / Open / Over Range / Under Range
Shows “Err” Indication
Up scale current : 22mA, Down scale current :
3.6mA to 3.9mA; Selectable
2) By Loop Current :
Electrical
Protection Class
Cabinet Material
Cable Entry
Dimension
Mounting
Weight
Industrial standard 4-20mA DC O/P with
permissible load 750 ohm at 24VDC, 25mA
0
Storage Temperature : -40 to +80 C +- 5%
o
Operating Temperature : 0 to 50 C +- 5%
: Below 95% Non-Condensing.
Humidity
: +- 1% of the Full Scale.
: T20 <
T50 <
T90 <
: Less than 30 Seconds.
Accuracy
Response Time
:
Standard
IP-65
Polycarbonate, grey colour
Thermoplastic cable gland (IP 68)
190 mm (H) x 80 mm (W) x 55 mm (D)
Wall Mounting / Stand Mounting / Pipe Mounting
Approx 250 Grams.
Cabinet Material
Cable Entry
Dimension
Mounting
Weight
: IP-65 for Gas Gr. IIA, IIB, CMRI approved
enclosure, CCOE (Optional).
: Cast Aluminium alloy, LM-6
: Double compression cable gland (Ex-Proof), ¾”
ET-type
: 190 mm (H) x 185 mm (W) x 100 mm (D)
: Wall Mounting / Stand Mounting / Pipe mounting
: Approx 1.0 Kg
List Of Gases With Ranges & Resolution
GASES
Oxygen
Oxygen
Nitrogen Dioxide (NO2)
Nitric Oxide (NO)
Sulphur Dioxide (SO2)
Chlorine (Cl2)
Carbon Monoxide (CO)
Hydrogen Sulphide (H2S)
Hydrogen Cynide (HCN)
Hydrogen Chloride (HCL)
SR. NO
1
2
3
4
5
6
7
8
9
10
RANGE
0-25%Vol.
0-100%Vol.
0-100 PPM
0-50 PPM
0-20 PPM
0-10 PPM
0-2000 PPM
0-200 PPM
0-10 PPM
0-50 PPM
RESOLUTION
0.1
0.1
1.0
0.1
0.1
0.1
1.0
0.1
0.1
0.1
SR. NO
11
12
13
14
15
16
17
18
19
GASES
Ammonia (NH3)
Ozone (O3)
Ethylene Oxide (C2H4O)
Phosphine (Ph3)
Hydrogen (H2)
Phosgene (COCL2)
Fluorine (F2)
Hydrogen Fluoride (HF)
Hydrogen Bromide (HBr)
RANGE
0-50 PPM
0-2 PPM
0-20 PPM
0-5 PPM
0-1000 PPM
0-1 PPM
0-100 PPM
0-50 PPM
0-10 PPM
RESOLUTION
0.1
0.1
0.1
0.1
1.0
0.1
0.1
0.1
0.1
Orderaing Information
GT
A
A)Model No.
1) - 1000
B
B) Enclosure
1) FLP
(Flameproof)
2) WP
(Weatherproof)
C
C) Input
Please select the
Serial No of the
gas from the list
given above.
D
E
D) SensorHousing
1) PVC material
2) Teflon
3) Stainless
Steel (SS316)
E) Power Supply
1) 24VDC
* Before placing order please Refer the above ordering information or Contact us for assistance.
* Please specify if any other gases not in the list ( Available on Request)