explosion proof stoppers explosion proof junction

advertisement
EXPLOSION PROOF GLANDS
Flameproof Glands
S.W.A. Glands
Size
FSG-0
FSG-1
FSG-2
FSG-3
FSG-4
0
1
2
3
4
Supplied
with
Shroud
Class 1 Zone 1 Cert. MS787/J608
For use on Exd equipment to SABS 314.
Group II Category 2GD, ATEX1087X
Size Cable Size Ø
124M20EX03 M20 6-12mm
124M25EX03 M25 13-18mm
124M32EX03 M32 18-25mm
Code
20mm
25mm
32mm
40mm
EPG-710002
EPG-710004
EPG-710006
EPG-710008
Code
Size
Code
20mm
25mm
32mm
40mm
EPC-706001
EPC-706002
EPC-706003
EPC-706004
FCG-00
FCG-0
FCG-1
FCG-2
FCG-3
FCG-4
Compression Glands
IP65
Class 1 Zone 1
Cert. MS787/J206
Size
Size
00
0
1
2
3
4
For Armored Cable
Double Seal IP66
EX Cable Glands Explosive Areas
IP68 5 Bar with strain relief black Polyamide
Code
Compression Glands
Code
II 2G Exd IIC
II 2G Exe II
EXPLOSION PROOF STOPPERS
Exe Stopping Plugs
Size Code
Alum. Alloy
L
L
BA-
BZ-
20mm
25mm
32mm
40mm
50mm
Length
L (mm)
BA-715001
17
BA-715002
17
BA-715003
20
BA-715004
20
BA-715005
20
Material: Aluminium Alloy, carbonate
Steel Zinc-Plated
II 2G Exd IIC
Code
Plastic
BZ-714002
BZ-714003
BZ-714004
BZ-714005
BZ-714006
II 2G Exe II
Length
L (mm)
10
12
12
14.5
15
EXPLOSION PROOF JUNCTION BOXES
BXJ8050-20B/6-4
BHD-D/M25
Type
Material
EX-Mark
Certificates
Gland Size
Terminals
Size
BHD51-G3/4I
Engineering Plastic
BXJ8050-20B/6-4
Terminal box
Glass fibre reinforced plastic
II 2G Exe II T6
PTB 03 ATEX 1021
M25 x 1.5
Posts 0.2-2.5mm² x 6
120 x 120 x 60mm
Suitable for Zone 1, 2, 21 and 22
Temperature range: -20˚C to +55˚C
TOXIC GAS SENSOR
Approval
Approval (BS EN 61326) Industrial
ATEX II 2 G
Span adjust
Connector
Zero adjust
Low range 4-20mA microprocessor transmitter
gas sensor. Transmitters are available with the
following pre-calibrated ranges:
Code
CO-BF-*
H2S-BF-*
SO2-BF-*
CH-A3-BF-*
Type
Carbon Monoxide
Hydrogen Sulphide
Sulphur Dioxide
Explosive gasses
*Add to code for ranges: 1 (0-500ppm)
2 (0-2000ppm)
Note: ppm (maximum gas concentration)
Note: CH-A3-BF-* detects multiple gas
• Propane • Carbon Minoxide • Benzene
• Methane • Ethylene
• Alcohol
FLP
Die-Cast Aluminium
BHD51-G3/4I
BHD-D/M25
Lightning Terminal Box
Terminal Box
Aluminium Alloy, powder-coated
II 2G Exd II BT6 / CT6
PTB 06 ATEX 1013
G3/4 (not incl.)
M25 x 1.5 (not incl.)
Posts 0.2-2.5mm²
DIN 2.5mm² x 6
Ø110 x 110H
Ø110 x 71H
Ideal for IIA, IIB and T6 Areas
4 to 20mA Transmitter Specifications
• Input voltage required: +7.5 to 35VDC
• Output at zero gas concentration (or 15% oxygen):
4mA (user adjustable)
• Output at full-scale (or 25% oxygen): 20mA (user
adjustable)
• Setability/ stability: <0.05mA (<0.25% full scale)
• Maximum load @ 20mA, 24VDC: 825ohms
• Supply voltage depandance: <±0.2% output from
+7.5 to 35VDC
• Connector: 2 pin Molex plug (ref 22-27-2021)
supplied with leads
• Transmitter current requirement: <100mA
FLAMEPROOF & TELEPHONES
Code
257
Sirens and Beacons:
Complies to STANDARD EXD 1/11C 150
FLAMEPROOF SIRENS & BEACONS
Flameproof Motorised Sirens
• Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
Code
Operating
Voltage
Range
Duty Cycle 1min on, 8min off
115VAC
EP500*
230VAC
EP500*
†
EP500
EX Mono & EX
Duplo
EP1500
Min Sound
at Rated
Voltage
(dB@1m)
Max
Current at Audible
Range
Rated
Voltage (A)
*Duty Cycle - Continuous
2
1200
1
1200
1000m
1000m
113 - Ex Duplo
113 - Ex Duplo
EP500†
EP500†
12VAC/DC
24VAC/DC
1200
1200
9
4.8
1000m
1000m
113 - Ex Mono
113 - Ex Mono
EP1500
EP1500
115VAC
230VAC
1600
1600
2.6
2.1
1500m
1500m
126
126
115VAC
230VAC
370/660
370/660
4.0
3.0
2000m
2000m
128
128
Duty Cycle 30min on, 10min off
EP2000
EP2000
EP2000
Frequency
(Hz)
Flameproof Electronic Sounder
• Maintenance free solid state sounder
• Four sounds from one unit for different applications
• High sound output with volume control
• Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
Code
EXS*
EXS Multi
Sounder
• High quality steel casting, precision engineered
• Rugged multipurpose weatherproof device
• Application: Class 1, 2 & 3, all groups. Division
1. 1 and 2 areas
FLAMEPROOF & TELEPHONES
EX Xenon & EX
LED
Description
Sound Output @1m
Flameproof Multi Sounder
93-113dB
*Add voltage: 12VDC, 24VDC, 115VAC, 230VAC
Flameproof Beacon
Code
Description
Colour
FPM
Light
EXF-A*
EXF-B*
EXF-G*
EXF-R*
Flameproof Beacon
Flameproof Beacon
Flameproof Beacon
Flameproof Beacon
● Amber
● Blue
● Green
● Red
110
110
110
110
Xenon Tube
Xenon Tube
Xenon Tube
Xenon Tube
EXFL-A*
EXFL-R*
EXFL-G*
Flameproof Beacon
Flameproof Beacon
Flameproof Beacon
● Amber
● Red
● Green
110
110
110
LED
LED
LED
*Add voltage: 12VDC, 24VDC, 110VAC, 230VAC
Flameproof Beacon and Sounder Combination
EX Multi Sounder &
LED Beacon
EX Multi Sounder &
Xenon Tube
Code
Colour
Light
Description
FPM
EXCL-A*
EXCL-G*
EXCL-R*
● Amber
● Green
● Red
LED
LED
LED
Flameproof Sounder and Beacon
Flameproof Sounder and Beacon
Flameproof Sounder and Beacon
110
110
110
EXCX-A*
EXCX-B*
EXCX-G*
EXCX-R*
EXCX*
● Amber
● Blue
● Green
● Red
*Add voltage: 12VDC, 24VDC, 115VAC, 230VAC
Colours
258
Xenon Tube
Xenon Tube
Xenon Tube
Xenon Tube
FLP
Flameproof Sounder and Beacon
Flameproof Sounder and Beacon
Flameproof Sounder and Beacon
Flameproof Sounder and Beacon
110
110
110
110
Sirens and Beacons:
Complies to STANDARD EXD 1/11C 150
EXPLOSION PROOF EQUIPMENT
Flameproof Sounders and Beacons
• Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
DB1
DB5
Min Sound
at Rated IP
Voltage Rating
(dB@1m)
Code
DB1 240VAC
240VAC
ABS
30mA
103
IP66
27 Tone
24VDC
ABS
250mA
103
IP66
27 Tone
24VDC
ABS
14mA
100
IP65
26 Tone
DB7
24VDC
Polyester
34mA
103
IP66
27 Tone
XB8
24VDC
Polyester
55mA
60F/M
IP66
Beacon
DB1 24VDC
DB5
XB8
Max
Current at
Rated
Voltage (A)
Operating
Voltage Material
Range
Tone
Manual Callpoint IP67
Description
Code
DB7
BG2
BG2
Switch Ratings: 0 to 30VDC – 5A (resistive) or 3A (inductive); 30 to 50VDC – 1A
­(resistive) or 3A (inductive); 0 to 254VAC – 5A (resistive) or 3A (inductive).
Material: UV resistant glass reinforced polyester.
EXH 24VAC
24VAC
PC/ABS
450mA
105
IP55
Horn
115VAC
PC/ABS
205mA
105
IP55
Horn
EXH 230VAC
230VAC
PC/ABS
70mA
105
IP66
Horn
GR3T 24VAC
230VAC
Aluminium
70mA
110
IP55
Siren
GR3T 115VAC 115VAC
Aluminium
150mA
110
IP55
Siren
12-24VAC/DC Aluminium
GR3T 24V
Above Sirens 100% continuous rated
160mA
109
IP55
Siren
EXH 115VAC
Aluminium Explosion-proof Beacon IP66 Xenon Tube
Colour
FPM
Connection
Code
GR3T
FHL113-A*
● Amber
110
3/4 inch
● Red
110
3/4 inch
110
● Green
*Add Voltage 24V (12-24VAC/DC), 110VAC, 230VAC
3/4 inch
FHL113-R*
FHL113-G*
Spare PCB c/w Xenon Tube
113/FH-PCB
113/FH-PCB 110V
110V P.C.B c/w Xenon Tube
113/FH-PCB 230V
230V P.C.B c/w Xenon Tube
Sounders Intrinsically safe zone 0, 1 & 2 Gas Group 11C
E2SIS
E5YIS
Code
Operating
Voltage Material
Range
E2SIS
24VDC
E5YIS
24VDC
Beacons
E2BIS-*
Max
Current at
Rated
Voltage (A)
ABS Flame retardant 25mA
UL94VO
ABS Flame retardant 93mA
UL94VO
24VDC
ABS Flame retardant 25mA
UL94VO
*Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
Sounder/Beacons
E25BIS-*
E2BIS
E25BIS
24VDC
ABS Flame retardant 48mA
UL94VO
*Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
FLP
113/FH-PCB 230V
Min Sound
at Rated IP
Voltage Rating
(dB@1m)
Tone
100
IP65
49 Tone
105
IP66
32 Tone
–
IP65
Beacon
100
IP65
49 Tone
FLAMEPROOF & TELEPHONES
FHL113
12/24VAC/DC P.C.B c/w Xenon Tube
259
According to IEC 79-12 Standard, each unit comes with its own unique test certificate.
SABS 314-1 Permit No 2295/3609 Coaltech
FLAMEPROOF EQUIPMENT
1 Way Control Stations
Zone 1 Group IIA, IIB, IIC
Code
Cast Iron
PBS71-START-*
PBS71-1-*
PBS71-2-*
PBS71-3-*
PBS71-6-*
CT/KMS-93-†
PBS71
Description
Enclosure
Size Code
Start Station
b
Padlockable Stop Station
b
b
Emergency Stop (spring return)
b
Emergency Stop (push/pull)
b
Emergency Stop Padlockable
a
Mining Key Switch
*Add ‘D’ for 1 x Top & 1 x Bottom 20mm entries, ‘B’ for 2 x 20mm bottom entries
†SC = shuttle car key, CM = continuous miner, DV = feeder bunker
CT/KMS-93
PBS72
2 Way Control Stations
PBS72-*
PBS72-3-*
b
b
Start/Stop Station
Emergency Stop (push/pull)/Start
*Add ‘D’ for 1 x Top & 1 x Bottom 20mm entries,
‘B’ for 2 x 20mm bottom entries
Enclosure Size Code: H x W x D (External)
a = 120 x 120 x 90 b = 144 x 100 x 75
Direct On Line Starter – No Terminal Box
Overload D.O.L.
Enclosure With
Enclosure
AC3 kW
Code
Size Code Isolator Size Code
400V 525V Range
4
5.5
7.5
11
15
18.5
22
30
37
45
5.5
7.5
10.5
15
18.5
22
30
37
45
55
FDL09
FDL12
FDL18
FDL25
FDL32
FDL40
FDL50
FDL65
FDL80
FDL95
7-10A
9-13A
12-18A
17-25A
23-32A
33-50A
33-50A
43-65A
54-80A
83-90A
c
c
c
d
d
f
f
f
f
f
/S
/S
/S
/S
/S
/S
/S
/S
/S
/S
d
d
d
e
e
f
f
f
f
f
Coil Voltage
AC
U = 240V
(170-280V)
N = 415V
(291-465V)
SF = 550V
(467-605V)
Enclosure Size Codes: H x W x D (External)
c = 210 x 150 x 115, d = 320 x 210 x 190, e = 320 x 150 x 135, f = 450 x 330 x 220
Isolators
FLAMEPROOF & TELEPHONES
ISO80
Description
Enclosure
Size Code
Cable Entries
ISO80/1/20
20 Amp 2 Pole Isolator
a
1 x Top & 1 x Bottom
20 Amp 3 Pole Isolator
a
1 x Top & 1 x Bottom
ISO80/3/32
32 Amp 3 Pole Isolator
a
1 x Top & 1 x Bottom
ISO160/3/32
32 Amp 3 Pole Isolator
g
2 x Bottom
40 Amp 3 Pole Isolator
g
2 x Bottom
63 Amp 3 Pole Isolator
g
2 x Bottom
80 Amp 3 Pole Isolator
g
2 x Bottom
ISO80/3/20
ISO160/3/40
ISO160/3/63
ISO160/3/80
Enclosure Size Codes: H x W x D (External)
a = 120 x 120 x 90 g = 210 x 150 x 135
ISO160
Switches
DETS
260
Code
Code
Description
SETS
DETS
LSWR80
Single Ended Trip Switch
Double Ended Trip Switch
Roller Limit Switch
Enclosure Size Codes: H x W x D (External)
c = 210 x 150 x 135 a = 120 x 120 x 90
FLP
Enclosure Cable Entries
Size Code
c
2 x Bottom
a
1 x Side
c
2 x Bottom
LSWR80
For Flameproof Glands see page 257.
EXPLOSION PROOF LIGHTING
Flood Light 230V IP66
Code High
Code
Code
Lamp
Watts
Pressure Sodium Lamp Metal Halide Lamp Empty Fitting Holder
70W
BAT53-HSE70G
100W
BAT53-HSE100G
250W
BAT53-HSE250G
400W
BAT53-HSE400G
(Lamps excluded.) See page 509 for lamps.
BAT53-HIE70G
BAT53-HIE100G
BAT53-HIE250G
BAT53-HIE400G
Description
400W
250W
70/100W
–
–
–
BAT53-EMPTY
Aluminium reflector IP66
Temperature range: -25°C to +55°C
Ex mark II2G Exde II BT3
ATEX: Group II category 2G
Ideal for IIA, IIB locations
Suitable for Zone 1, 2 and 21, 22 locations
Material: Die cast aluminium alloy outer shell
High pressure anti static plastic sprayed
Silicon rubber seal, high grade anodic
Bulkhead IP65
Code
Watts
BAD-A200X
Lamp Type
200W
160W
20W
70W
BAD61-HSE70X
100W
BAD61-HSE100X
(Lamps excluded.) See page 509 for lamps.
(empty fitting for use
with a variety of lamps)
E27
E40
E40
E40
Incandescent or
Mercury Blended or
Energy Saving CFL
High Pressure Sodium. c/w ballast & ignitor
High Pressure Sodium. c/w ballast & ignitor
Lamp
Holder
E27
E27
E27
Description
BAD61
ATEX: Group II2G Exd II CT4
Ideal for IIA, IIB, IIC areas
Suitable for Zone 1 and Zone 2 locations. (Certificate No. PTB 03 ATEX 1077)
Energy Saving Lighting IP65
Code
Watts
Lamp
Holder
Lamp Type
BAD81-42X
BAD81-68X
42W
Energy Saving CFL
68W
Energy Saving CFL
Lamps included. Suitable for ceiling mounting.
Description
BAD81-42X
BAD81-68X
E27
E27
Accessories
Atex: Group II Category 2G
Ideal for IIA, IIB, IIC areas
Suitable for zone 1, 2 and 21, 22
Exmark:
II 2G Exd II CT4
Code
81004
81005
Description
42W Spare lamp
68W Spare lamp
Urano Floodlights Asymmetrical Diffused (wide beam) 230V 50Hz IP55
Note: FLP
­discounts
apply
Code
Watts
Lamp Type
GW84134M
GW84224
150W
MD Metal Halide
Optional wire guard
(Complete with lamp) ATEX: Class
II3GD T4. Zone 2G to Zone 22D
Titano Asymmetrical Diffused Floodlights (wide beam) 230V IP66
GW84592M
GW84594M
GW84407
250W
MT Metal Halide
400W
MT Metal Halide
Optional wire guard
(Complete with lamp) ATEX: Class
II3GD T3. Zone 2G to Zone 22D
Halle-High Bay 230V IP65 Control Gear. 470mmØ bowl
GW83563S
GW83564M
GW83566S
GW83567M
GW84814
250W
250W
400W
400W
Optional wire guard
(Complete with lamp) ATEX: Class
FLP
SE High Pressure Sodium
ME Metal Halide
SE High Pressure Sodium
ME Metal Halide
Current
1.8A
Lamp
Holder
Rx7s
2.2A
3.4A
E40
E40
3A
2.2A
4.2A
3.4A
E40
E40
E40
E40
FLAMEPROOF & TELEPHONES
BAD-125X
II3GD T4. Zone 2G to Zone 22D
261
EXPLOSION PROOF LIGHTING
Cable not included
Toughened Glass
Code
c/w battery charger
BSX-60
BAD203
≤100W (E27)
­–
­–
II 2G Exde II CT4
Zones 1 & 2
IP65
Ø138 x 433mm
Spare Glass: BSX102
Power Supply
Battery life
Charging time
Ex Mark
Zone
IP-Rating
Size
Spares
Beacon/ Sounder - ≥80dB
c/w battery charger
7.2V 2Ah Battery (incl.)
≥10hrs
4.5-6hrs
II 2G Exib II CT6
Zones 1 & 2
IP68
Ø40 x 208mm
Battery 203-BAT
BAD303
3.6V 1.8Ah Battery (incl.)
≥10hrs
4.5hrs
II 2G Exib II CT6
Zones 1 & 2
IP66
Ø25 x 120mm
Battery 201-BAT
6V 4.5Ah Battery (incl.)
High Intensity: 1-2hrs. Working light: ≥10hrs
12-16hrs
II 2G Exde II CT4
Zones 1 & 2
IP68
105 x 53 x 153 (excl. head)
Battery 303-BAT
Beacon
II 2G Exd II CT6
Code
Code
Colour
BBJ-ZG-*
● Green
BJD-ZG-*
BBJ-ZR-*
Colour
● Green
● Red
BJD-ZR-*
● Red
BBJ-ZY-*
● Yellow
BJD-ZY-*
● Yellow
BBJ-ZB-*
● Blue
BJD-ZB-*
● Blue
*Add voltage to code: 110VAC, 230VAC
Description
• LED lamp, low energy consumption, long service life
• IP-Rating IP65
• Flash frequency: 150/min
• Cable entry c/w cable seal-ring and locking device
FLAMEPROOF & TELEPHONES
BAD201
LED EXPLOSION PROOF BEACONS
II 2G Exd [ib] ib II CT6
Contacts: 1NO + 1NC
6A @ 220/380VAC
c/w battery
charger
• Suitable for use in Zones 1 & 2
• Ideally suited for use in IIA, IIB and IIC areas.
• Glass cover resistant to temperature changes
• Housing in aluminium alloy, powder-coated
EXPLOSION PROOF LIMIT SWITCHES IP65
Cable entry: M20
c/w cable gland
Code
BZX51-6D
Ex mark:
262
II 2G Exed II CT6
BZX51-6S
Suitable for: Zone 1 & 2
FLP
BZX51-6Z
Group IIA, IIB, IIC class T6 or below
BZX51-6L
EXPLOSION PROOF CONTROL STATIONS IP65
-K1
-A1-R
-A2-C
-A3-R/G/E
-A2-R/G
-A1-C
-A1-G
-A3-R/G/L -A3-R/G/S
-16/2
-16/3
-32/2
-32/3
Code
Description
BZA8050-K1
On/Off Selector Switch 1 x N/O (10A)
BZA8050-A1-G
Gland Enclosure Size
Size H x W x D (mm)
M25
107 x 85 x 87
Start Pushbutton 1N/O
M25
107 x 85 x 87
BZA8050-A1-R
Stop Pushbutton 1 N/C
M25
107 x 85 x 87
BZA8050-A1-C
Emg. Stop Twist to release 1N/C
M25
107 x 85 x 87
BZA8050-A2-C
Emg. Stop (Twist to release 1N/C) & Start
M25
139 x 85 x 87
BZA8050-A2-R/G
Start/Stop 1N/O & 1N/C
M25
139 x 85 x 87
BZA8050-A3-R/G/L
Start/stop and LED pilot light c/w 1N/O + 1N/C per
button
M25
185 x 85 x 87
BZA8050-A3-R/G/E
Start/stop and emergency stop (twist to release)
c/w 1N/O + 1N/C per button
M25
185 x 85 x 87
BZA8050-A3-R/G/S
Start/stop and selector 3 position stay put switch c/w 1N/O M25
+ 1N/C per button (switch can be used as auto-off-man)
185 x 85 x 87
BZZ8050-16/2
16A 2-Pole Isolator Padlockable
M25
139 x 110 x 109
BZZ8050-16/3
16A 3-Pole Isolator Padlockable
M25
139 x 110 x 109
BZZ8050-32/2
32A 2-Pole Isolator Padlockable
M25
220 x 130 x 109
BZZ8050-32/3
32A 3-Pole Isolator Padlockable
M25
220 x 130 x 109
Pushbutton 1N/O
Isolating Switches
Explosion protection:
II 2G Exed II CT6
Material: Glass fibre reinforced polyester resin
ATEX Classification Group II Category 2GD. Suitable for Zone 1, 2 and 21, 22 locations.
Rated working voltage: 220VAC/380VAC
Rated working current: 10A
EXPLOSION PROOF PUSHBUTTONS & PILOT LIGHTS
Push Button Flush
Pilot Light Head
Selector Switch
●
EX8050-R
EX8050-PLR
EX8050-SS
Green ●
EX8050-G
EX8050-PLG
Yellow ●
EX8050-Y
EX8050-PLY
White
–
EX8050-PLW
Colour
Red
●
Contact Blocks
Description
1N/O
1N/C
EMG-Stop Twist
Release
EX8050-EMG
EX8050-NO
EX8050-NC
Description
24VAC
110VAC
On/Off Key Switch
EX8050-40093
EX8050-KS
Isolating Switch On/Off
LED Lamp Blocks
Code
EMG-Stop
Push/Pull Button
Code
EX8050*-24VAC
EX8050*-110VAC
EX8050*-230VAC
Description
2 Pole 10A
4 Pole 10A
Code
EX8050-2P
EX8050-4P
FLAMEPROOF & TELEPHONES
2-Position stay-put
230VAC
*Add colour of lamp to code: ● R (Red), ● G (Green), ● Y (Yellow), ● W (White)
FLP
263
POWER QUALITY ANALYSERS
Optional accessories for MI-2092 & MI-2192
Description
MI-2192
Mini Clamp 100A/1V
(range 2A + 100A)
MI-2092
Code
Power Quality Testing
RMS Voltages, Currents (average, min., max)
THD Harmonics Analysis
Power: Active, Reactive, Apparent Cos Φ character sign
Voltage Events (dips,sags, interruptions)
Periodic Analysis
Statistical Analysis
Anomalies (Events) Analysis
Neutral current (calculated)
Online monitoring
Meter mode –tabelaric results
Scope mode – oscilloscope
Spectrum Analysis mode
EN 50160 compliant testing
Fast Set Up – auto mode
Voltage
THD & Harmonics
Dips, Sags, Interruptions
Flicker
Frequency
Interharmonics/Signalling
Unbalance
EN 50160 test report
Special tools
FAST LOGGING mode
WAVEFORM mode
TRANSIENT mode
Energy
Total
Subtotal counters
MI-2192
MI-2092
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Optional
✔
✔
✗
✔
✔
✔
✗
✔
✗
✗
✗
✔
✔
✔
✗
✗
✗
✔
✔
✔
✔
Code
A1069
Clamp Adaptor
A1039
Flex Clamp 3000A/1V
(range 60A + 3000A)
A1120
Current Transformer
5A/1V
(range 0.1A + 5A)
IA1037
MI-2192 & MI-2092 Set
comprises of:
• Instrument
• Current clamp 1000A/1V,
(range 20A + 1000A), 3pcs
• Test tip, 3pcs
• Alligator clip, 4pcs
• Voltage measurement cable,
6pcs
• Mains cable
• Soft carrying bag
• Small soft carrying bag
• Instruction manual
• Declaration of conformity
• Product verification data
• Power Link PC software with
RS 232 cable
ENERGY ANALYSERS
Parameters:
TEST INSTRUMENTS, TOOLS & GENSETS
PQA702
• Instantaneous: W, VA, VAr, V, A, TPF, DPF, Hz
• Max demand: W, VA, A, programmable 1 to 60m
• Automatic calculation of kVAr necessary to compensate low PF
• Maximum and minimum calculations (single phase
and system ­variables): W, VA, VAr, V, A, DPF, TPF,
Hz, THD, THD odd, THD even (THD is considered
for both current and voltage)
• Energies: +Wh, -Wh, +VArh, -VArh +VAh, -VAh (also
by time period)
• FFT analysis (harmonic distortion): histogram indication up to 50th harmonic, numerical and percentage
indication of harmonic content of both voltage and
current. THD, THD odd, THD even and single harmonic measurement
Data Recording:
Windows 95/98 based software
• Start measuring period: programmable from 00:00h
to 23:59h
• Data intergration time interval (10ms sampling) programmable from 1-999s (15 min)
• Data References: date and time
• Available memory: 1 Mb ram
Code:
CA3000Q
Accessories included with PQA702
264
Accessories
CA1000H
FLEX3000Q
Code:
PQA702 New
PQA700-H Unit for hiring
PQA700-R Hire charge per day
Portable Power Quality Analyser
• Measurement of all electrical variables, harmonic
analysis and other parameters. Includes printer,
carry case and ­accessories.
• Printer: Impact Dot Matrix, paper width 54mm
• Power Supply: 230VAC ±15% plus internal
­rechargeable ­battery (Life: 1 hour)
• Carrying case/weight: 160 x 340 x 510mm /
Instrument: 3.7kg, the whole set: 10kg
• Standard accessories included:
4 voltage-measuring cables, length 3m
1 RS232 cable + 9-25 pole adaptor
1 power supply cable
1 analysis software (PqaSoft)
1 instruction manual (English, Italian & Spanish)
1 CA1000H: current clamp probe 1000AAC, jaw
­opening 52mm, cable length 2m, accuracy 0.5%
@ 1000A.
Rental facility available per day/visit. Compulsory
separate insurance is required.
Current clamp probe 1-10-100-1000AAC, jaw opening 52mm, cable length
2m. Accuracy: 0.7% @ 1A, 0.5% @ 10A, 0.3% @ 100A,
0.2% @ 1000A
Current clamp probe 3000AAC, jaw opening 90mm, internal ­dimensions 65
x 150mm, cable length 2m. Accuracy: 1.5% @ 150A, 0.75% @ 1600A,
0.5% @ 3000A
Flexible current clamp 0.5A to 3000A
MET
20MHZ HANDHELD DUAL CHANNEL SCOPE METER
Technical Specifications:
Bandwidth: 20MHz x 2 channels
Sampling Rate: real time 100M Sa/sec
Horizontal sensitivity: 5ns/div-5s/div, ±0.01%
Horizontal resolution: 5ns
Memory depth: 2k per channel
Vertical sensitivity: 5mV/div-5V/div, ±5%
Vertical resolution: 8 bit
Rise time: 17.5ns
Trigger mode: Auto, Normal, Single time, Edge, TV
Max. input voltage: 300V DC + AC peak
Input impedance: 1MΩ ±2%, 20pF ±3pF
Input coupling: DC & AC
Waveform maths: +, -, *, /
Auto measurement: Freq, Period, Vpp, Vavg, Vrms
Cursor measurement V, T
Max. recording length: 6k samples per channel
Screen storage: 4 screens and 4 settings
Display: 3.8 inch 320 x 240 pixels color LCD with backlit
Code:
DMM Functions:
DCV/ACV: 400m/4/40/400V, ±1.0%
DCA/ACA: 40m/400m/20A, ±1.5%
OHM: 400/4k/40k/400k/4M/40MΩ, ±1.0%.
CAP: 51.2n/512n/5.12µ/51.2µ/100µF, ±3.0%
Audible continuity: (<50Ω) & diode test
Battery: 7.4V/1500mAh lithium, 6 hours
Power consumption: <6W
Dimensions & weight: 180x113x40mm, approx. 690g
Accessories: AC adaptor, interface wire & software, probes
DS1022M
• 3 3/4 digital multimeter built with dual channel scope of
20MHz bandwidth, 320x240p colour
LCD display
• Waveform maths, auto and cursor ­measurement
• True RMS, relative measurement
• USB interface to computer
• Ideal tool for use in Lab., school, ­factory, field work and
home wiring ­repair, etc.
SOLAR MODULE ANALYSER
PROVA200
Analyser
•Voltage range: 0-60VDC
•Current range: 0-6A
• I-V Curve test for solar cell
• Maximum solar power (Pmax) search by
Auto-scan (60V, 6A)
• Maximum voltage (Vmaxp) at Pmax
SAFETY GLOVES
CUST.GI
CE Approved
VPG90
Test V
2500V
PROVA300XP
5kV
Printer
• Maximum current (Imaxp) at Pmax
• Voltage at open circuit (Vopen)
• Current at short circuit
• Calculation of efficiency (%)
• Manual single point test
User V
500V
1kV
7.5kV
10kV
17kV
20kV
30kV
Size
Code
Code
Code
Code
Code
8
GI2,5-8
GI5-8
GI10-8
GI20-8
GI30-8
9
GI2,5-9
GI5-9
GI10-9
GI20-9
GI30-9
10
GI2,5-10
GI5-10
GI10-10
GI20-10
GI30-10
11
GI2,5-11
GI5-11
GI10-11
GI20-11
GI30-11
26.5kV
Accessories
Protective plastic case for gloves
Pneumatic Tester. This tester inflates the gloves and you can detect any perforation on the dielectric of the gloves
CUST.GI
VPG90
Insulated Rubber Carpet in 3 & 6mm thickness x 1 metre wide – priced per metre
IRC-3
3mm x 1 metre (w). Voltage test 30000V, max use voltage 26500V
MET
IRC-3
TEST INSTRUMENTS, TOOLS & GENSETS
Code
Description
265
HIGH VOLTAGE TEST EQUIPMENT
High Voltage Proximity Detector
High Voltage Multifunction Phasing Sticks
• Lightweight • Designed for maximum safety • Carry case included
HP275
Description:
The HP275 is a high voltage proximity ­detector. It
has eight voltage detection settings from 240VAC
to 275kVAC. The HP275 consists of an internal
pickup sensor plate, a sensitivity selector, a visual
and an audible annunciator. With the HP275,
physical ­contact with electrical conductors is not
­necessary when testing for live lines. This tester
works by proximity.
Features:
• 8 voltage settings: Test 240VAC, 2kV, 6kV, 11kV,
22kV, 33kV, 132kV and 275kV.
• High bright LEDs visual indication.
• Sound indication.
• Easy-to-prove method.
• Self-test selection.
• Uses 3 x 1.5V “D” batteries.
• High impact nylon and rubber casing.
• Non-contact work by proximity.
• Compatible with most link sticks.
• Light weight, robust & compact.
• Water resistant for outdoor use.
• Detects low voltage on any system.
Code
System Voltage
Full Scale Voltage
Maximum Voltage
PC-7K
PC-11K
PC-22K
PC-33K
PC-44K
6.6kV
11kV
22kV
33kV
44kV
8kV
12kV
24kV
36kV
48kV
9kV
15kV
30kV
40kV
55kV
Accessories
Code
(for all models)
PC-BK
PC-C1K
PC-C2K
Cone tips
30mm
Specifications:
Electrical
Total resistance
Neon threshold
Neon fully lit @
Respond Time <1 sec
PC-7K
±3.95MΩ
1.2kV
1.5kV
Mechanical
PC-11K
±6.78MΩ
1.2kV
1.5kV
Description
90º bends (pair)
30mm cone tips (pair)
70mm cone tips (pair)
70mm
PC-22K
±13.5MΩ
1.2kV
1.5kV
PC-33K
±20.1MΩ
1.2kV
1.5kV
PC-44K
±27MΩ
1.2kV
1.5kV
Handle length
765mm
765mm
765mm
765mm
765mm
Front end length
340mm
340mm
460mm
610mm
760mm
Total length
1105mm
1105mm
1225mm
1375mm
1525mm
Total weight
±1.2kg
±1.2kg
±1.3kg
±1.4kg
±1.5kg
Handle material: Composite material with polyurethane
Front end: Fibre glass wound tubing
Environmental
Operating temp.: -25°C to +55°C
Operating humidity: 20 to 96% RH
Short Circuiting and Grounding
Short circuiting and grounding equipment for electrical cabinets and MV installations
with universal contact clamps
Code
Description
TEST INSTRUMENTS, TOOLS & GENSETS
MT/BM-25 Standard type. lcc: 13,7kA eff / 0.25s With short circuit cables section
MT/BM
25mm2
MT/BM-50 With short circuit cables section 50mm2 Icc: 13kA eff / 0.5s
MT/BM-95 With short circuit cables section 95mm2 Icc: 24kA eff / 0.5s
Certificate complies to the International Standard CEI EN 61230 (CEI IEC 1230)
Fuse Extraction Rod
EF30
EF30
Insulating Rod for fuse extraction and installation
on systems with working voltages up to 30kV
Phasing and Voltage Detector of MV Presence / Absence by
Visual Signalling (Indoor Use)
Code
RMB36
RMB36
c/w case
266
MET
Description
• Double poles voltage detector
• Phase relationship detector
• HV fuse tester
• Operating range: 5/36 kV
• Total length of each rod complete with antenna: 1,17m
DIGITAL/ANALOG MULTIMETERS
Digital Clamp Meter
Digital
Insulation Tester
Hand Crank
Insulation Tester
Analogue/Digital
Insulation Tester
Analog Earth
Resistance Tester
PSE-266F
PSE-261
KC-60B
• AC Current: 1000A
• DC Volts: 1000VDC
• AC Volts: 750VAC
• Diode tester
• Audible continuity
• Frequency: 2Hz
• Data hold
• OHMS: 0-2MΩ
• Accepts adaptor for insulation
tester
PSE-261
Plug-in Insulation Tester for
266 Series Clamp Meter
Rated voltage: 500V DC
Ranges: 20MΩ, ±2.0%
2000MΩ, ±4.0%
• Zero Adjustment: automatic
• Test Voltage: 500V
• Rated Voltage: switchable
• Insulation Resistance:
250V/500V/1000V, ±10%
• OHM Meter:
• Measuring Range:
0Ω to 500MΩ
0-500M/1000M/2000MΩ,
res. 1MΩ
• Basic Accuracy: ±4% +2dgt
• Short Circuit Output: 1.7mA/
1.7mA/1.4mA
• Input Resistance: 2M/2M/ 5MΩ
RCD Tester
TEL1-3 (230V)
TEL1-4 (240V)
• Verifies that the wiring is correct (Neon light indication)
• RCD testing with variable fault current
• Trip settings 10 - 35mA
MiniTrip 1/L
As MINITRIP 1
with 15A plug
and lead.
150mA also
available
NB311110
2732IN
Analog
• 250V/100MΩ
• 500V/200MΩ
• 1000V/400MΩ
• AC Volts: 600V/750VAC
• Continuity Test: 0-100Ω/20,
200, 2kΩ
• Timer 3 to 5 min
• ± 5% F.S. accuracy
• Auto off
• Hold
• Auto discharge
• Battery operated (excl.)
• Supplied with test leads
• c/w carrying case
Earth Leakage Testers
MiniTrip 1
• Wiring check
• 5-55mA Stepped output. Earth ­current test
rated at 230VAC
• 50/60Hz
• Rotary switch
selection
• Push button injection
MiniTrip 2
• Analogue
• 10-50mA variable
earth current
• Wiring check
• 50/60Hz
• Potentiometer
selection
• 230VAC ±15%
Uni-Trip 50/150
50 or 150mA range 3 phase
Earth Leakage Tester
ST-1505
• Earth resistance
10-100-1000Ω
• Earth voltage:
0-30VAC
• 800Hz ± 2mA
• 6 x 1.5V batteries (excl.)
• Supplied with test leads
Loop/PSC/Earth H.V. Insulation
2820EL
• Digital
• Sensitivity test:
5-999mA (@ 317VL-E)
• Time delay test:
0.000-99.999S
• Sensitivity accuracy:
± 1mA
• Time delay accuracy:
± 2ms
• Multi-Voltage 100400VAC
• 50Hz only
• Auto-off
MET
2751IN
Digital
2726NA
• Digital
• Line impedance
• Neutral impedance
• Earth impedance
• Voltage L-N
• Voltage L-E
• PSC L-N
• PSC L-E
• Scroll through
results
• 50Hz 230V ± 20%
• Auto-ranging
• Auto-off
• c/w carrying case
2803IN 2804IN
max 5kV max 10kV
• 1kV, 2.5kV, 5kV, 10kV
test voltage
• ± 5% F.S.
• Up to 500GΩ/10kV
• 8 x 1.5V AA alkaline
batteries (excl.)
• Digital display
• Timer
• Bargraph
• Auto-hold – Auto-off
• Auto-discharge
• Non isolated circuit sensing
TEST INSTRUMENTS, TOOLS & GENSETS
PSE-266F
267
DIGITAL CLAMP METERS
Model
Description
Basic Accuracy
Ranges
AC Voltage
DC Voltage
True RMS AC
AC Current
DC Current
Resistance
Frequency
MS2600
ST-330
AC current up to 400A AC Current up to
200A
Data hold
Data hold
Peak hold
Open jaw
Easy to use
±2.5% rdg ± 4 dgt
Diode test
200mV to 600V
200mV to 600V
No
2A to 400A
–
200Ω to 20Ω
–
1000V
700V
No
200A
–
400Ω to 40MΩ
10kHz to 100kHz
ST-9700
MS2026R
AC/DC current up to
600A. Data Hold
Buzzer for continuity test.
Temperature -20°C to
1000°C. K-Probe (included)
±1.5% rdg ± 4 dgt
AC current up to 1000A
Data hold
Peak hold
Capacitance test
600nF to 100 µF
±1.5% rdg ± 5 dgt
Diode test
Auto ranging
0 to 700V
0 to 1000V
Yes
0 to 1000A
–
600V
200V
No
200A/600A
200A/600A
0Ω to 2KΩ
–
40Hz to 100KHz
AC/DC Current
Up to 1000A
Autoranging
Max, data/hold
Buzzer for continuity
±1.2% rdg ± 3 dgt
Diode test
True RMS - 3810 only
0 to 600V
0 to 600V
No
Yes
Up to 1000A
Up to 1000A
0Ω to 200KΩ
–
Multi-Tester
MS-2000G
ST-600
• Analogue clamp
meter.
• AC current 0-600A
• Pointer lock function
• Range switch
• Ω Range
Basic Accuracy
• AC current 2000A
• Data hold
• Frequency and temperature
measurement
• Clamp size 55mmØ
• Auto power off
• Diode and continuity check
±2.5%
Ranges
DC Voltage
1000V
TEST INSTRUMENTS, TOOLS & GENSETS
AC Voltage
True RMS AC
AC Current
DC Current
Resistance
Frequency
Temp
268
400mV to 700V
400mV to 1000V
Yes
20A to 2000A
200A to 2000A
0Ω to 2KΩ
50-60Hz
Capacitance Meter
TES-1500
Description
AC/DC Current up to 2000A.
True RMS measure­ment.
Frequency measurement.
Relative reading
±1.9% rdg ± 5 dgt
Diode test
DIGITAL/ANALOGUE MULTIMETERS
Clamp Meters
Model
BM2000B
3810
2605
±3% of full scale
750V
150/300/600V
No
No
200/2000A
–
2mΩ
20kHz
0-750°C
–
6/30/60/300/600A
–
0 to 2KΩ
–
–
ST-365TRB
• 3 colour and mirror scale
• Safety fused
• HFe and dB
• ± 3% F.S. DC accuracy
• ± 4% F.S. AC accuracy
• DC mA 50µA, 2.5, 25, 250mA
• Ω 2K to 20M
• VAC/VDC 0 to 1000V
• 20kΩ/Volt AC
• 1kΩ/Volt DC
Pocket Multimeter
ST-112
• Pocket size
• High speed
auto­ranging
• Bargraph
• AC Volts: 500VAC
• DC Volts:500VDC
• OHMS: 40MΩ
• Diode test
• Capacitance: 200µF
MET
TES-1550
TES-1500
• 0.5% Accuracy
• Overload Fuse protection
• Test Clips/Direct insert jack for easy
measurement
Range:
200pF/ 2nF/ 20nF/ 2µF/ 200µF/
2000µF/ 20mF
Measurement Voltage 4.5V max.
Test frequency 8/80/800Hz
Principle Dual Stop Integration
Zero Aro Adjustment ±20pF Approx.
Automotive Meter
TES-1550
• Engine RPM Measurement
• Auto-power off
• Water-proof ABS housing
• Tacho: 10-10,000RPM (±2%rdg±1dgt)
Dwell: %/4CYL/6CYL/8CYL
DC/AC Current 40m/400m/20A
DC/AC Voltage (±0.5%rdg±1dgt)
400m/4/40/400/750V(AC)/1000V(DC)
Resistance 400/4k/40k/400k/4M/40MΩ
Capacitance 4n/40n/400n/4µF/40µF
Frequency 100/1k/10k/100k/500kHz
DIGITAL MULTIMETERS
Description
MAS830
VC9808
MS8221A
TES-2700
Large LCD Display
Transistor test
6 Functions
19 ranges
Great value!
Last reading
hold
Large LCD Display
Transistor test
7 Functions
24 ranges
Great value!
Last reading
hold
Auto-ranging
Data hold
Spraywater-protected
Temp measures:
-40 to 1000°C
(Probe included)
Peak hold
Auto-ranging
Data hold
Spraywaterprotected
Bargraph
±0.5% rdg ± 2 dgt
±0.5% rdg ± 2 dgt
AC Voltage
100mV to 600V
1mV to 750V
DC Voltage
Diode Test
AC Current
DC Current
Resistance
Capacitance
Frequency
100mV to 600V
Yes
–
0.1mA to 10A
0.1Ω to 2MΩ
–
–
0.1mV to 1000V
Yes
1mA to 10A
0.1mA to 10A
0.1Ω to 20MΩ
–
–
±0.5% rdg ± 2 dgt
200mV to 700V
(40 to 400Hz)
200mV to 1000V
Yes
2mA to 20A
2mA to 20A
200Ω to 2000MΩ
20nF to 200µF
100Hz to 20MHz
±0.5% rdg ± 2 dgt
3.2V to 600V
(40 to 400Hz)
320mV to 600V
Yes
200µA to 20A
200µA to 20A
320Ω to 30MΩ
–
–
Accuracy
Ranges
Code
Description
Accuracy
Ranges
AC Voltage
DC Voltage
Diode Test
AC Current
DC Current
Resistance
Capacitance
Frequency
Continuity Test
ST-992
ST-2009
ST-9918
MS8226T
True RMS
Auto Ranging
Data hold
LCD backlit
RS232C interface
to computer
Temp: -20°C to
1000°C
±0.5% rdg ± 1 dgt
400mV to 700V
400mV to 1000V
Yes
400µA to 10A
400A to 10A
400Ω to 40MΩ
40nF to 100µF
4Hz to 40KHz
ST-9932FC
Auto Ranging
Data Hold
Auto Power off
Max hold
Temp measuring to 760°C
K-Probe (included)
Auto Ranging
Data Hold
Auto Power off
Temp measuring to 760°C
K-Probe (included)
Min/Max recording mode
Auto Ranging
Temp measuring to 760°C
K-Probe (included)
Data Hold
Auto Ranging
Data Hold
Auto Power off
Temp measuring to 1000°C
K-Probe (incl)
With RS-232 cable and
Software interface to
computer
0.5%rdg + 2dgt
600V
600V
Yes
10A
10A
2MΩ
–
–
Yes
0.5%rdg + 2dgt
700V
1000V
Yes
20A
20A
40MΩ
100f
9.999MHz
Yes
±0.5%rdg + 2dgt
600V
600V
Yes
10A
10A
40MΩ
200f
10MHz
Yes
0.8%rdg + 3dgt
750V
1000V
Yes
20A
20A
40MΩ
100f
9.999MHz
Yes
MET
MY980
True RMS
Spraywaterprotected
Data hold
±0.5% rdg ± 1 dgt
400mV to 700V
(40 to 1000Hz)
400mV to 1000V
Yes
2mA to 10A
2mA to 10A
200Ω to 200MΩ
2000PF to 20µF
20KHz
MS8264
• 30 ranges, 3 1/2 digits LCD
display • AC voltage
­detection with LED indicator
• Enhanced protection on
all ranges: 200mA selfresume fuse, 1000V
­discharge capacitors, PTC,
metal board shielding
• Data hold and new LCD
­illumination • Temp:
-40°C-1000°C
0.8%rdg + 3dgt
2V to 750V
200mV to 1000V
Yes
10A
10A
200MΩ
200f
200KHz
Yes
TEST INSTRUMENTS, TOOLS & GENSETS
Model
269
Multimeter True RMS & Data Logger
DIGITAL MULTIMETERS
AC/DC Power Clamp Meter
PC Adaptor and Software
For 3 phase/3
wires (balanced &
unbalanced) power
measurement
(included)
PROVA 803
PROVA 901
• Dual Input Channels
• Dual Channels Measurement similar to a Dual Channels DSO
(V+V, V+A)
• Hz+Duty Cycle Dual Display
• Standalone Data Logging of
10 708 Records both Channels
• RS-232C Interface, application
software (option)
• The New Standard of DMM
• Bandwidth 10kHz (max.)
• Basic Accuracy 0.04% (DC) and
0.2% (AC)
– DCV/ACV: 60.000mV-1000.0V
– DCA/ACA: 600.00µA-10.000A
– Resistance: 999.99Ω-40.000MΩ
– Capacitance: 60.00nF-600.0µF
– Frequency: 1.000Hz-2mHz
– Duty-Cycle and Diode Test
• Dual Input Channels
• Compare Voltage at two different
locations
• Read Voltage and Current at the
same time
• Optical Isolated RS-232C ASCII
Interface
• True RMS
• The New Standard of DMM
• Bandwidth 200kHz
• Basic Accuracy 0.02% (DC) and
0.1% (AC)
– DCV/ACV: 60.000mV-1000.0V
– DCA/ACA: 600.00µA-10.000A
– Resistance: 999.99Ω-40.000MΩ
– Capacitance: 60.00nF-600.0µF
– Frequency: 1Hz-2.000kHz
– Duty-Cycle and Diode Test
Phase Sequence
Indicator
Digital Phase
Indicator
TES-3063 (c/w software)
• 1600 Point Data logging function
• True Power/Apparent Power/Power
Factor Measurement
• True RMS. V, A, W
• 4 digits with 2” LCD Display
• MIN/MAX/AVG Measurement
• Amp/Voltage Frequency Measurement
• PEAK HOLD Detector
• 3 Phase adaptor for 3 phase power
­measurement
• Peak hold/Data hold
Range
• True Power: 600kW (AC/DC)
• Apparent Power: 600kVA (AC/DC)
• Power factor: 0.3-1 Capacitive
0.3-1 Inductive
-72.5° -0- +72.5°
UPT/SPT Cable
Tester
Network Cable
Tester
TES-3064 (PC adaptor)
• To down load the data into the
­computer from datalogging memory
of TES-3063
• Communicates with PC via RS-232
for ­further data analysis and reports
RS232/485
• DC/ACA: 1000A
• OHM: 10KV
• Continuity: below 100V
• Hz: 1Hz -300KHz
Cable/Wire
Tracer
Multi-Network
Cable Tester
TEST INSTRUMENTS, TOOLS & GENSETS
Cat 5E, Cat 6, BNC
Cable Tester
ST-850
• Check phase sequence
• Open phase check
• 90-600VAC range
• 50/60Hz
• -10°C – +40°C
operating
• 540g (no battery
required)
• Instruction manual
• Carrying case
• Intermittent rated
270
SSP-8030
• Designed to check the
­presence of open phase and
phase sequence by LED
and buzzer at the same time
Specifications
• Operational Voltage: 200480V AC three phase
• Time limit for continuous
use: 60 minutes max. at
200V AC. 4 minutes max. at
480V AC
• Frequency range:
20Hz-400Hz
• Accessories: double­
­insulated cords, probes for
test leads
KT-200
• Test UTP and STP wiring of
T568A, T568B, 10Base-T,
100Base-T and Token ring
­network
• Tests for open circuits, shorts,
miswires, reversals, split pairs
and cable’s shield integrity
• DEBUG mode quickly identifies
which cable pairs have a
­specific wiring fault
• Warning: do not use on live
­circuits
Cable length specifications
• Minimum UTP/STP cable
length for testing – 1 metre
• Maximum UTP/STP cable
length for testing – 200 metres
MET
KT-201
• Length test range
300m
• Accuracy ±5%
• Resolution 0.1m
• 16 x 2 LCD characters
• Cable continuity
• Suitable for computer
network systems
• Warning: Do not use
on live circuits
MS6812
• Designed to identify and
trace wires or cables
within a group without
damaging the insulation
• Continuity test
• Volume control for
increased sensitivity
• Recessed ON/OFF
­button to prevent battery
drain
Specifications
• Emitter tone frequency:
1.5kHz
• Receiver frequency
range: 100-300kHz
MS6810
• Designed to autoscan
the wires of Ethernet
(BNC/TNC)
AT&T258A, EIA/
TIA568 token ring &
modular cables
• Auto checks for open
circuits, shorts,
misplaced wires &
reversals
• Tester designed for
testing before or after
cables have been
installed
• Quick & easy fault
detecting
VOLTAGE TESTERS
901
Double Pole Voltage Detector
• Solenoid indication for AC and DC
voltage readings.
• Black makrolon case, oil-proof and
non-burnable rubber grips with
­elastic finger guards.
• Neon indication for voltage present
and bright indicator scale for voltage range.
Specifications
• DC Voltage: 120-220-440-750V
• AC Voltage: 125-220-380-500-750V
• Cable: 1m in length
• Construction: Handles are double
insulated against electricity and
heat
MV-400
MV-4
• Test Voltage AC/DC: 6-400VAC/DC
• Polarity test
• Max. Testing Time: 30 sec
BESTEST 8
• Test Voltage 12-600VAC/DC
• LED indication 12-24-50-120-230400-600V
• Max operating time: 30 sec
• High voltage insulated 1000V
Voltage Finders
• Testing Voltage AC & DC: 6-400VAC/DC
• Phase indication via LED (symbol ‘R’)
• Polarity via LED
• Test Earth Leakage CB via F1 ­push
­button
• Continuity and semiconductor test 0-1MΩ
• Max. Testing Time: 30 sec
MS8211
• DC V: 600V
• Auto Ranging
• Data/max value hold
• AC V: 600V
• Diode Test
• OHM: 200Ω to
20MΩ
• Non-contact AC voltage detection
with flashlight
AC-9
• 100-600VAC
• Rugged double moulded case
• Built-in bright flash light
• Flashing red LED indication
Battery Testers
M38900
• 90-600VAC 50/600Hz
• Easy to use, just touch the tip to an
outlet or cord, when it glows red, you
know there’s voltage
• Fits in your pocket • 2xAAA bat(incl.)
BESTEST 7
• AC Voltage: 100-250VAC
AT-953
MV-2
• AC Voltage: Contact Test
70-500VAC
• Non Contact Test: 70-600VAC
• DC Volts Test: Up to 2500VDC
• Continuity Check: 0-50M Ohm
• Microwave leakage detection,
5mW sq cm
• Battery Tester
• Plugs into car lighter
• 5 indicators: Low/Fair/Normal/Full
& Over
• Battery and Alternator Tester
• Alternator (engine ON):
High – 15.0V
Normal – 140V
Low – 13.5V
• Battery (engine OFF):
Normal – 12.5V
Low – 12.0V
Flat – 5.0V
• Max operating period: 10 sec
Professional cable locator
BT-12
BT-6
• 3 in 1 Battery/Bulb/Fuse tester
• To test batteries type: AA, AAA, C,
D, 9V, E, I, SV and PV
Magnetic Field Tester
Automotive Current Tester
Maxi-Blade
LA-1012
• Can trace cable in wall & underground
• Tracing cable depth: 0-2.5m
• Detects faults in cables and under-floor heating
• Can trace metallic water & heating pipes
• Receiver incl. torch
• Digital signal ensures clear signal identification
• Can be used on live or dead cables
• 2 x 9V Battery included
AC-8M
• Testing of solenoids and relays
• The test lamp illuminates when a magnetic field is present
• No metallic contact is required
• Responds to AC and DC magnetic fields and permanent magnets
CF-02
Circuit Breaker Identifier
Mini-Blade
CF-02S
• Measuring range: 20A @ 48VDC/ AC
(10sec. max)
• Resolution: 10mA
• Cable length: 75cm
• Plugs straight into automotive fuse
holder in car
MET
• 12VDC Battery Analyser
• Voltage Test 8-25VDC
• On load battery test. This test
evaluates the battery’s ability to
crank an engine
• Charging system test
• Starter motor test
191CBI
Easy tool to find the C/B or Fuse
without disconnecting the supply.
Plug the transmitter into the outlet
socket, use the receiver to scan the
C/B Panel to find the correct C/B
­supplying power to the socket
TEST INSTRUMENTS, TOOLS & GENSETS
BESTEST 18
271
DIGITAL METERS
Infrared Thermometers
Code
Humidity & Temp Meters
ST-8818
-50°C to 550°C
-58°F to 1022°F
0.1° up to 200°
Resolution:
1° over 200°
±1.5% of reading or ±2°C/
Basic Accuracy:
±4°F (whichever is greater)
Optical Resolution: 12:1 Distance to Spot size
Fixed at 0.95
Emissivity:
9V Battery (Incl.)
Battery:
• Laser targeting
Features:
• Automatic Data hold
• Auto Power Off
• User selectable °C or °F
• Response time: 1 sec
Laser & Probe
IR-88
ST-616CT
-20°C to 270°C
-4°F to 518°F
ST-8860
-20°C to 1000°C
-4°F to 1832°F
0.1% RH
0.1° to 200° 1°>200°C
-50°C to 1300°C
-58°F to 2000°F
0.1% RH
0.1°C/1°C
±2% or ±2°C/±4°F
±3%
±0.5% + 1d
6:1
Fixed at 0.95
1.5V AAA Battery x 2 (Incl.)
• Laser targeting
• Data & max hold
• Auto Power Off
• User selectable °C or °F
• Low Battery indication
• Response time: 1 sec
K-Type Probe
included
9V Battery (Incl.)
• Laser targeting
• Large LCD with dual
display
• Max & hold function
• Auto Power Off
• Low Battery indication
K-Type Probe
included
9V Battery (Incl.)
• Large display
• Max & hold
function
• Auto Power Off
• Low Battery indication
Range:
K Type Thermocouple Probes
Pocket size
1°C/°F
Laser Tachometer
Digital Sound Level
Temperature Meters
ST-610B
ST-612
-50°C to 1300°C
-58°F to 2000°F
0.1°C or 1°C/°F
± 1°C
K-Type Probe
included
9V Battery (Incl.)
• Large display
• Data & max hold
• (T1-T2) modes
Freezes Display for
­convenient viewing (306)
Lightmeter
Anemometer
Laser &
contact
TEST INSTRUMENTS, TOOLS & GENSETS
DT-2236
• Non Contact RPM using
reflecting tape and contact
measuring
• Contact measurement
TPK-04
TPK-03
TPK-01
• 5 Digit LCD display
• Auto range, from 10.0 to
TPK-01 Bead Probe Measures
surface or air ­temperatures to 260°C
99.999RPM
(500°F). 1.2m long wire has an indus- • Measuring distance max
try ­standard ­miniature connector plug.
2metres
TPK-03 Immersion Probe
• Resolution:
General ­purpose ­needle type with
0.1RPM (<1000RPM)
stainless sheath. Use for
1.0RPM (≥1000RPM)
­measurements up to 800°C (1472°F)
• Memory recall button
TPK-04 Surface Probe Miniature, • Accuracy: ± 0.05%
fast response probe, with 800°C
• Accessories: Reflecting
(1472°F) max. surface temperature.
strips
Ideal for measuring the surface tem•
4 x 1.5V AA batteries (Incl.)
perature of small electronic parts.
272
ST-8850
MS-6610
AVM-01
• 0.1dB Resolution
• Range from 35 to 130dB
• Maximum hold function
• A & C frequency weightings
• Fast & Slow dynamic
­characteristic models
• Analogue AC/DC output
for connection to an
analyzer or recorder
• T ypical instrument frequency
range: 31Hz to 8KHz
• Accuracy ±1.5dB
• Time weighting: Slow and
Fast
• Maximum hold:
Delay<1dB/3min
• Microphone: Electric
­condenser microphone
Features:
• Cosine Angular ­corrected
• Analogue output jack for
recording (1332/1334)
• Data hold function.
Range (±3%rdg ±0.5%f.s)
200/2000/20000/50000
Lux
20000 lux-reading x 10;
200000 lux-reading x 100
Over-range Display:
Highest digit of (1) is
­displayed
Features:
• Measures wind speed & direction
• Backlight
• Size: 208 x 72mm vane
head
Range (±2%rdg±0.1)
M/S: (Metre/per Sec.) 0.4- 30.0
KNOTS: 0.8-58.3
Ft/s: 2-98.5
Km/H: 1.4-108.0
Display: Large 3 1/2 digit
LCD
• 1 x 9V Battery (Incl.)
• Auto power off
• Data hold function
MET