EXPLOSION PROOF GLANDS Flameproof Glands S.W.A. Glands Size FSG-0 FSG-1 FSG-2 FSG-3 FSG-4 0 1 2 3 4 Supplied with Shroud Class 1 Zone 1 Cert. MS787/J608 For use on Exd equipment to SABS 314. Group II Category 2GD, ATEX1087X Size Cable Size Ø 124M20EX03 M20 6-12mm 124M25EX03 M25 13-18mm 124M32EX03 M32 18-25mm Code 20mm 25mm 32mm 40mm EPG-710002 EPG-710004 EPG-710006 EPG-710008 Code Size Code 20mm 25mm 32mm 40mm EPC-706001 EPC-706002 EPC-706003 EPC-706004 FCG-00 FCG-0 FCG-1 FCG-2 FCG-3 FCG-4 Compression Glands IP65 Class 1 Zone 1 Cert. MS787/J206 Size Size 00 0 1 2 3 4 For Armored Cable Double Seal IP66 EX Cable Glands Explosive Areas IP68 5 Bar with strain relief black Polyamide Code Compression Glands Code II 2G Exd IIC II 2G Exe II EXPLOSION PROOF STOPPERS Exe Stopping Plugs Size Code Alum. Alloy L L BA- BZ- 20mm 25mm 32mm 40mm 50mm Length L (mm) BA-715001 17 BA-715002 17 BA-715003 20 BA-715004 20 BA-715005 20 Material: Aluminium Alloy, carbonate Steel Zinc-Plated II 2G Exd IIC Code Plastic BZ-714002 BZ-714003 BZ-714004 BZ-714005 BZ-714006 II 2G Exe II Length L (mm) 10 12 12 14.5 15 EXPLOSION PROOF JUNCTION BOXES BXJ8050-20B/6-4 BHD-D/M25 Type Material EX-Mark Certificates Gland Size Terminals Size BHD51-G3/4I Engineering Plastic BXJ8050-20B/6-4 Terminal box Glass fibre reinforced plastic II 2G Exe II T6 PTB 03 ATEX 1021 M25 x 1.5 Posts 0.2-2.5mm² x 6 120 x 120 x 60mm Suitable for Zone 1, 2, 21 and 22 Temperature range: -20˚C to +55˚C TOXIC GAS SENSOR Approval Approval (BS EN 61326) Industrial ATEX II 2 G Span adjust Connector Zero adjust Low range 4-20mA microprocessor transmitter gas sensor. Transmitters are available with the following pre-calibrated ranges: Code CO-BF-* H2S-BF-* SO2-BF-* CH-A3-BF-* Type Carbon Monoxide Hydrogen Sulphide Sulphur Dioxide Explosive gasses *Add to code for ranges: 1 (0-500ppm) 2 (0-2000ppm) Note: ppm (maximum gas concentration) Note: CH-A3-BF-* detects multiple gas • Propane • Carbon Minoxide • Benzene • Methane • Ethylene • Alcohol FLP Die-Cast Aluminium BHD51-G3/4I BHD-D/M25 Lightning Terminal Box Terminal Box Aluminium Alloy, powder-coated II 2G Exd II BT6 / CT6 PTB 06 ATEX 1013 G3/4 (not incl.) M25 x 1.5 (not incl.) Posts 0.2-2.5mm² DIN 2.5mm² x 6 Ø110 x 110H Ø110 x 71H Ideal for IIA, IIB and T6 Areas 4 to 20mA Transmitter Specifications • Input voltage required: +7.5 to 35VDC • Output at zero gas concentration (or 15% oxygen): 4mA (user adjustable) • Output at full-scale (or 25% oxygen): 20mA (user adjustable) • Setability/ stability: <0.05mA (<0.25% full scale) • Maximum load @ 20mA, 24VDC: 825ohms • Supply voltage depandance: <±0.2% output from +7.5 to 35VDC • Connector: 2 pin Molex plug (ref 22-27-2021) supplied with leads • Transmitter current requirement: <100mA FLAMEPROOF & TELEPHONES Code 257 Sirens and Beacons: Complies to STANDARD EXD 1/11C 150 FLAMEPROOF SIRENS & BEACONS Flameproof Motorised Sirens • Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas Code Operating Voltage Range Duty Cycle 1min on, 8min off 115VAC EP500* 230VAC EP500* † EP500 EX Mono & EX Duplo EP1500 Min Sound at Rated Voltage (dB@1m) Max Current at Audible Range Rated Voltage (A) *Duty Cycle - Continuous 2 1200 1 1200 1000m 1000m 113 - Ex Duplo 113 - Ex Duplo EP500† EP500† 12VAC/DC 24VAC/DC 1200 1200 9 4.8 1000m 1000m 113 - Ex Mono 113 - Ex Mono EP1500 EP1500 115VAC 230VAC 1600 1600 2.6 2.1 1500m 1500m 126 126 115VAC 230VAC 370/660 370/660 4.0 3.0 2000m 2000m 128 128 Duty Cycle 30min on, 10min off EP2000 EP2000 EP2000 Frequency (Hz) Flameproof Electronic Sounder • Maintenance free solid state sounder • Four sounds from one unit for different applications • High sound output with volume control • Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas Code EXS* EXS Multi Sounder • High quality steel casting, precision engineered • Rugged multipurpose weatherproof device • Application: Class 1, 2 & 3, all groups. Division 1. 1 and 2 areas FLAMEPROOF & TELEPHONES EX Xenon & EX LED Description Sound Output @1m Flameproof Multi Sounder 93-113dB *Add voltage: 12VDC, 24VDC, 115VAC, 230VAC Flameproof Beacon Code Description Colour FPM Light EXF-A* EXF-B* EXF-G* EXF-R* Flameproof Beacon Flameproof Beacon Flameproof Beacon Flameproof Beacon ● Amber ● Blue ● Green ● Red 110 110 110 110 Xenon Tube Xenon Tube Xenon Tube Xenon Tube EXFL-A* EXFL-R* EXFL-G* Flameproof Beacon Flameproof Beacon Flameproof Beacon ● Amber ● Red ● Green 110 110 110 LED LED LED *Add voltage: 12VDC, 24VDC, 110VAC, 230VAC Flameproof Beacon and Sounder Combination EX Multi Sounder & LED Beacon EX Multi Sounder & Xenon Tube Code Colour Light Description FPM EXCL-A* EXCL-G* EXCL-R* ● Amber ● Green ● Red LED LED LED Flameproof Sounder and Beacon Flameproof Sounder and Beacon Flameproof Sounder and Beacon 110 110 110 EXCX-A* EXCX-B* EXCX-G* EXCX-R* EXCX* ● Amber ● Blue ● Green ● Red *Add voltage: 12VDC, 24VDC, 115VAC, 230VAC Colours 258 Xenon Tube Xenon Tube Xenon Tube Xenon Tube FLP Flameproof Sounder and Beacon Flameproof Sounder and Beacon Flameproof Sounder and Beacon Flameproof Sounder and Beacon 110 110 110 110 Sirens and Beacons: Complies to STANDARD EXD 1/11C 150 EXPLOSION PROOF EQUIPMENT Flameproof Sounders and Beacons • Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas DB1 DB5 Min Sound at Rated IP Voltage Rating (dB@1m) Code DB1 240VAC 240VAC ABS 30mA 103 IP66 27 Tone 24VDC ABS 250mA 103 IP66 27 Tone 24VDC ABS 14mA 100 IP65 26 Tone DB7 24VDC Polyester 34mA 103 IP66 27 Tone XB8 24VDC Polyester 55mA 60F/M IP66 Beacon DB1 24VDC DB5 XB8 Max Current at Rated Voltage (A) Operating Voltage Material Range Tone Manual Callpoint IP67 Description Code DB7 BG2 BG2 Switch Ratings: 0 to 30VDC – 5A (resistive) or 3A (inductive); 30 to 50VDC – 1A ­(resistive) or 3A (inductive); 0 to 254VAC – 5A (resistive) or 3A (inductive). Material: UV resistant glass reinforced polyester. EXH 24VAC 24VAC PC/ABS 450mA 105 IP55 Horn 115VAC PC/ABS 205mA 105 IP55 Horn EXH 230VAC 230VAC PC/ABS 70mA 105 IP66 Horn GR3T 24VAC 230VAC Aluminium 70mA 110 IP55 Siren GR3T 115VAC 115VAC Aluminium 150mA 110 IP55 Siren 12-24VAC/DC Aluminium GR3T 24V Above Sirens 100% continuous rated 160mA 109 IP55 Siren EXH 115VAC Aluminium Explosion-proof Beacon IP66 Xenon Tube Colour FPM Connection Code GR3T FHL113-A* ● Amber 110 3/4 inch ● Red 110 3/4 inch 110 ● Green *Add Voltage 24V (12-24VAC/DC), 110VAC, 230VAC 3/4 inch FHL113-R* FHL113-G* Spare PCB c/w Xenon Tube 113/FH-PCB 113/FH-PCB 110V 110V P.C.B c/w Xenon Tube 113/FH-PCB 230V 230V P.C.B c/w Xenon Tube Sounders Intrinsically safe zone 0, 1 & 2 Gas Group 11C E2SIS E5YIS Code Operating Voltage Material Range E2SIS 24VDC E5YIS 24VDC Beacons E2BIS-* Max Current at Rated Voltage (A) ABS Flame retardant 25mA UL94VO ABS Flame retardant 93mA UL94VO 24VDC ABS Flame retardant 25mA UL94VO *Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue) Sounder/Beacons E25BIS-* E2BIS E25BIS 24VDC ABS Flame retardant 48mA UL94VO *Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue) FLP 113/FH-PCB 230V Min Sound at Rated IP Voltage Rating (dB@1m) Tone 100 IP65 49 Tone 105 IP66 32 Tone – IP65 Beacon 100 IP65 49 Tone FLAMEPROOF & TELEPHONES FHL113 12/24VAC/DC P.C.B c/w Xenon Tube 259 According to IEC 79-12 Standard, each unit comes with its own unique test certificate. SABS 314-1 Permit No 2295/3609 Coaltech FLAMEPROOF EQUIPMENT 1 Way Control Stations Zone 1 Group IIA, IIB, IIC Code Cast Iron PBS71-START-* PBS71-1-* PBS71-2-* PBS71-3-* PBS71-6-* CT/KMS-93-† PBS71 Description Enclosure Size Code Start Station b Padlockable Stop Station b b Emergency Stop (spring return) b Emergency Stop (push/pull) b Emergency Stop Padlockable a Mining Key Switch *Add ‘D’ for 1 x Top & 1 x Bottom 20mm entries, ‘B’ for 2 x 20mm bottom entries †SC = shuttle car key, CM = continuous miner, DV = feeder bunker CT/KMS-93 PBS72 2 Way Control Stations PBS72-* PBS72-3-* b b Start/Stop Station Emergency Stop (push/pull)/Start *Add ‘D’ for 1 x Top & 1 x Bottom 20mm entries, ‘B’ for 2 x 20mm bottom entries Enclosure Size Code: H x W x D (External) a = 120 x 120 x 90 b = 144 x 100 x 75 Direct On Line Starter – No Terminal Box Overload D.O.L. Enclosure With Enclosure AC3 kW Code Size Code Isolator Size Code 400V 525V Range 4 5.5 7.5 11 15 18.5 22 30 37 45 5.5 7.5 10.5 15 18.5 22 30 37 45 55 FDL09 FDL12 FDL18 FDL25 FDL32 FDL40 FDL50 FDL65 FDL80 FDL95 7-10A 9-13A 12-18A 17-25A 23-32A 33-50A 33-50A 43-65A 54-80A 83-90A c c c d d f f f f f /S /S /S /S /S /S /S /S /S /S d d d e e f f f f f Coil Voltage AC U = 240V (170-280V) N = 415V (291-465V) SF = 550V (467-605V) Enclosure Size Codes: H x W x D (External) c = 210 x 150 x 115, d = 320 x 210 x 190, e = 320 x 150 x 135, f = 450 x 330 x 220 Isolators FLAMEPROOF & TELEPHONES ISO80 Description Enclosure Size Code Cable Entries ISO80/1/20 20 Amp 2 Pole Isolator a 1 x Top & 1 x Bottom 20 Amp 3 Pole Isolator a 1 x Top & 1 x Bottom ISO80/3/32 32 Amp 3 Pole Isolator a 1 x Top & 1 x Bottom ISO160/3/32 32 Amp 3 Pole Isolator g 2 x Bottom 40 Amp 3 Pole Isolator g 2 x Bottom 63 Amp 3 Pole Isolator g 2 x Bottom 80 Amp 3 Pole Isolator g 2 x Bottom ISO80/3/20 ISO160/3/40 ISO160/3/63 ISO160/3/80 Enclosure Size Codes: H x W x D (External) a = 120 x 120 x 90 g = 210 x 150 x 135 ISO160 Switches DETS 260 Code Code Description SETS DETS LSWR80 Single Ended Trip Switch Double Ended Trip Switch Roller Limit Switch Enclosure Size Codes: H x W x D (External) c = 210 x 150 x 135 a = 120 x 120 x 90 FLP Enclosure Cable Entries Size Code c 2 x Bottom a 1 x Side c 2 x Bottom LSWR80 For Flameproof Glands see page 257. EXPLOSION PROOF LIGHTING Flood Light 230V IP66 Code High Code Code Lamp Watts Pressure Sodium Lamp Metal Halide Lamp Empty Fitting Holder 70W BAT53-HSE70G 100W BAT53-HSE100G 250W BAT53-HSE250G 400W BAT53-HSE400G (Lamps excluded.) See page 509 for lamps. BAT53-HIE70G BAT53-HIE100G BAT53-HIE250G BAT53-HIE400G Description 400W 250W 70/100W – – – BAT53-EMPTY Aluminium reflector IP66 Temperature range: -25°C to +55°C Ex mark II2G Exde II BT3 ATEX: Group II category 2G Ideal for IIA, IIB locations Suitable for Zone 1, 2 and 21, 22 locations Material: Die cast aluminium alloy outer shell High pressure anti static plastic sprayed Silicon rubber seal, high grade anodic Bulkhead IP65 Code Watts BAD-A200X Lamp Type 200W 160W 20W 70W BAD61-HSE70X 100W BAD61-HSE100X (Lamps excluded.) See page 509 for lamps. (empty fitting for use with a variety of lamps) E27 E40 E40 E40 Incandescent or Mercury Blended or Energy Saving CFL High Pressure Sodium. c/w ballast & ignitor High Pressure Sodium. c/w ballast & ignitor Lamp Holder E27 E27 E27 Description BAD61 ATEX: Group II2G Exd II CT4 Ideal for IIA, IIB, IIC areas Suitable for Zone 1 and Zone 2 locations. (Certificate No. PTB 03 ATEX 1077) Energy Saving Lighting IP65 Code Watts Lamp Holder Lamp Type BAD81-42X BAD81-68X 42W Energy Saving CFL 68W Energy Saving CFL Lamps included. Suitable for ceiling mounting. Description BAD81-42X BAD81-68X E27 E27 Accessories Atex: Group II Category 2G Ideal for IIA, IIB, IIC areas Suitable for zone 1, 2 and 21, 22 Exmark: II 2G Exd II CT4 Code 81004 81005 Description 42W Spare lamp 68W Spare lamp Urano Floodlights Asymmetrical Diffused (wide beam) 230V 50Hz IP55 Note: FLP ­discounts apply Code Watts Lamp Type GW84134M GW84224 150W MD Metal Halide Optional wire guard (Complete with lamp) ATEX: Class II3GD T4. Zone 2G to Zone 22D Titano Asymmetrical Diffused Floodlights (wide beam) 230V IP66 GW84592M GW84594M GW84407 250W MT Metal Halide 400W MT Metal Halide Optional wire guard (Complete with lamp) ATEX: Class II3GD T3. Zone 2G to Zone 22D Halle-High Bay 230V IP65 Control Gear. 470mmØ bowl GW83563S GW83564M GW83566S GW83567M GW84814 250W 250W 400W 400W Optional wire guard (Complete with lamp) ATEX: Class FLP SE High Pressure Sodium ME Metal Halide SE High Pressure Sodium ME Metal Halide Current 1.8A Lamp Holder Rx7s 2.2A 3.4A E40 E40 3A 2.2A 4.2A 3.4A E40 E40 E40 E40 FLAMEPROOF & TELEPHONES BAD-125X II3GD T4. Zone 2G to Zone 22D 261 EXPLOSION PROOF LIGHTING Cable not included Toughened Glass Code c/w battery charger BSX-60 BAD203 ≤100W (E27) ­– ­– II 2G Exde II CT4 Zones 1 & 2 IP65 Ø138 x 433mm Spare Glass: BSX102 Power Supply Battery life Charging time Ex Mark Zone IP-Rating Size Spares Beacon/ Sounder - ≥80dB c/w battery charger 7.2V 2Ah Battery (incl.) ≥10hrs 4.5-6hrs II 2G Exib II CT6 Zones 1 & 2 IP68 Ø40 x 208mm Battery 203-BAT BAD303 3.6V 1.8Ah Battery (incl.) ≥10hrs 4.5hrs II 2G Exib II CT6 Zones 1 & 2 IP66 Ø25 x 120mm Battery 201-BAT 6V 4.5Ah Battery (incl.) High Intensity: 1-2hrs. Working light: ≥10hrs 12-16hrs II 2G Exde II CT4 Zones 1 & 2 IP68 105 x 53 x 153 (excl. head) Battery 303-BAT Beacon II 2G Exd II CT6 Code Code Colour BBJ-ZG-* ● Green BJD-ZG-* BBJ-ZR-* Colour ● Green ● Red BJD-ZR-* ● Red BBJ-ZY-* ● Yellow BJD-ZY-* ● Yellow BBJ-ZB-* ● Blue BJD-ZB-* ● Blue *Add voltage to code: 110VAC, 230VAC Description • LED lamp, low energy consumption, long service life • IP-Rating IP65 • Flash frequency: 150/min • Cable entry c/w cable seal-ring and locking device FLAMEPROOF & TELEPHONES BAD201 LED EXPLOSION PROOF BEACONS II 2G Exd [ib] ib II CT6 Contacts: 1NO + 1NC 6A @ 220/380VAC c/w battery charger • Suitable for use in Zones 1 & 2 • Ideally suited for use in IIA, IIB and IIC areas. • Glass cover resistant to temperature changes • Housing in aluminium alloy, powder-coated EXPLOSION PROOF LIMIT SWITCHES IP65 Cable entry: M20 c/w cable gland Code BZX51-6D Ex mark: 262 II 2G Exed II CT6 BZX51-6S Suitable for: Zone 1 & 2 FLP BZX51-6Z Group IIA, IIB, IIC class T6 or below BZX51-6L EXPLOSION PROOF CONTROL STATIONS IP65 -K1 -A1-R -A2-C -A3-R/G/E -A2-R/G -A1-C -A1-G -A3-R/G/L -A3-R/G/S -16/2 -16/3 -32/2 -32/3 Code Description BZA8050-K1 On/Off Selector Switch 1 x N/O (10A) BZA8050-A1-G Gland Enclosure Size Size H x W x D (mm) M25 107 x 85 x 87 Start Pushbutton 1N/O M25 107 x 85 x 87 BZA8050-A1-R Stop Pushbutton 1 N/C M25 107 x 85 x 87 BZA8050-A1-C Emg. Stop Twist to release 1N/C M25 107 x 85 x 87 BZA8050-A2-C Emg. Stop (Twist to release 1N/C) & Start M25 139 x 85 x 87 BZA8050-A2-R/G Start/Stop 1N/O & 1N/C M25 139 x 85 x 87 BZA8050-A3-R/G/L Start/stop and LED pilot light c/w 1N/O + 1N/C per button M25 185 x 85 x 87 BZA8050-A3-R/G/E Start/stop and emergency stop (twist to release) c/w 1N/O + 1N/C per button M25 185 x 85 x 87 BZA8050-A3-R/G/S Start/stop and selector 3 position stay put switch c/w 1N/O M25 + 1N/C per button (switch can be used as auto-off-man) 185 x 85 x 87 BZZ8050-16/2 16A 2-Pole Isolator Padlockable M25 139 x 110 x 109 BZZ8050-16/3 16A 3-Pole Isolator Padlockable M25 139 x 110 x 109 BZZ8050-32/2 32A 2-Pole Isolator Padlockable M25 220 x 130 x 109 BZZ8050-32/3 32A 3-Pole Isolator Padlockable M25 220 x 130 x 109 Pushbutton 1N/O Isolating Switches Explosion protection: II 2G Exed II CT6 Material: Glass fibre reinforced polyester resin ATEX Classification Group II Category 2GD. Suitable for Zone 1, 2 and 21, 22 locations. Rated working voltage: 220VAC/380VAC Rated working current: 10A EXPLOSION PROOF PUSHBUTTONS & PILOT LIGHTS Push Button Flush Pilot Light Head Selector Switch ● EX8050-R EX8050-PLR EX8050-SS Green ● EX8050-G EX8050-PLG Yellow ● EX8050-Y EX8050-PLY White – EX8050-PLW Colour Red ● Contact Blocks Description 1N/O 1N/C EMG-Stop Twist Release EX8050-EMG EX8050-NO EX8050-NC Description 24VAC 110VAC On/Off Key Switch EX8050-40093 EX8050-KS Isolating Switch On/Off LED Lamp Blocks Code EMG-Stop Push/Pull Button Code EX8050*-24VAC EX8050*-110VAC EX8050*-230VAC Description 2 Pole 10A 4 Pole 10A Code EX8050-2P EX8050-4P FLAMEPROOF & TELEPHONES 2-Position stay-put 230VAC *Add colour of lamp to code: ● R (Red), ● G (Green), ● Y (Yellow), ● W (White) FLP 263 POWER QUALITY ANALYSERS Optional accessories for MI-2092 & MI-2192 Description MI-2192 Mini Clamp 100A/1V (range 2A + 100A) MI-2092 Code Power Quality Testing RMS Voltages, Currents (average, min., max) THD Harmonics Analysis Power: Active, Reactive, Apparent Cos Φ character sign Voltage Events (dips,sags, interruptions) Periodic Analysis Statistical Analysis Anomalies (Events) Analysis Neutral current (calculated) Online monitoring Meter mode –tabelaric results Scope mode – oscilloscope Spectrum Analysis mode EN 50160 compliant testing Fast Set Up – auto mode Voltage THD & Harmonics Dips, Sags, Interruptions Flicker Frequency Interharmonics/Signalling Unbalance EN 50160 test report Special tools FAST LOGGING mode WAVEFORM mode TRANSIENT mode Energy Total Subtotal counters MI-2192 MI-2092 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Optional ✔ ✔ ✗ ✔ ✔ ✔ ✗ ✔ ✗ ✗ ✗ ✔ ✔ ✔ ✗ ✗ ✗ ✔ ✔ ✔ ✔ Code A1069 Clamp Adaptor A1039 Flex Clamp 3000A/1V (range 60A + 3000A) A1120 Current Transformer 5A/1V (range 0.1A + 5A) IA1037 MI-2192 & MI-2092 Set comprises of: • Instrument • Current clamp 1000A/1V, (range 20A + 1000A), 3pcs • Test tip, 3pcs • Alligator clip, 4pcs • Voltage measurement cable, 6pcs • Mains cable • Soft carrying bag • Small soft carrying bag • Instruction manual • Declaration of conformity • Product verification data • Power Link PC software with RS 232 cable ENERGY ANALYSERS Parameters: TEST INSTRUMENTS, TOOLS & GENSETS PQA702 • Instantaneous: W, VA, VAr, V, A, TPF, DPF, Hz • Max demand: W, VA, A, programmable 1 to 60m • Automatic calculation of kVAr necessary to compensate low PF • Maximum and minimum calculations (single phase and system ­variables): W, VA, VAr, V, A, DPF, TPF, Hz, THD, THD odd, THD even (THD is considered for both current and voltage) • Energies: +Wh, -Wh, +VArh, -VArh +VAh, -VAh (also by time period) • FFT analysis (harmonic distortion): histogram indication up to 50th harmonic, numerical and percentage indication of harmonic content of both voltage and current. THD, THD odd, THD even and single harmonic measurement Data Recording: Windows 95/98 based software • Start measuring period: programmable from 00:00h to 23:59h • Data intergration time interval (10ms sampling) programmable from 1-999s (15 min) • Data References: date and time • Available memory: 1 Mb ram Code: CA3000Q Accessories included with PQA702 264 Accessories CA1000H FLEX3000Q Code: PQA702 New PQA700-H Unit for hiring PQA700-R Hire charge per day Portable Power Quality Analyser • Measurement of all electrical variables, harmonic analysis and other parameters. Includes printer, carry case and ­accessories. • Printer: Impact Dot Matrix, paper width 54mm • Power Supply: 230VAC ±15% plus internal ­rechargeable ­battery (Life: 1 hour) • Carrying case/weight: 160 x 340 x 510mm / Instrument: 3.7kg, the whole set: 10kg • Standard accessories included: 4 voltage-measuring cables, length 3m 1 RS232 cable + 9-25 pole adaptor 1 power supply cable 1 analysis software (PqaSoft) 1 instruction manual (English, Italian & Spanish) 1 CA1000H: current clamp probe 1000AAC, jaw ­opening 52mm, cable length 2m, accuracy 0.5% @ 1000A. Rental facility available per day/visit. Compulsory separate insurance is required. Current clamp probe 1-10-100-1000AAC, jaw opening 52mm, cable length 2m. Accuracy: 0.7% @ 1A, 0.5% @ 10A, 0.3% @ 100A, 0.2% @ 1000A Current clamp probe 3000AAC, jaw opening 90mm, internal ­dimensions 65 x 150mm, cable length 2m. Accuracy: 1.5% @ 150A, 0.75% @ 1600A, 0.5% @ 3000A Flexible current clamp 0.5A to 3000A MET 20MHZ HANDHELD DUAL CHANNEL SCOPE METER Technical Specifications: Bandwidth: 20MHz x 2 channels Sampling Rate: real time 100M Sa/sec Horizontal sensitivity: 5ns/div-5s/div, ±0.01% Horizontal resolution: 5ns Memory depth: 2k per channel Vertical sensitivity: 5mV/div-5V/div, ±5% Vertical resolution: 8 bit Rise time: 17.5ns Trigger mode: Auto, Normal, Single time, Edge, TV Max. input voltage: 300V DC + AC peak Input impedance: 1MΩ ±2%, 20pF ±3pF Input coupling: DC & AC Waveform maths: +, -, *, / Auto measurement: Freq, Period, Vpp, Vavg, Vrms Cursor measurement V, T Max. recording length: 6k samples per channel Screen storage: 4 screens and 4 settings Display: 3.8 inch 320 x 240 pixels color LCD with backlit Code: DMM Functions: DCV/ACV: 400m/4/40/400V, ±1.0% DCA/ACA: 40m/400m/20A, ±1.5% OHM: 400/4k/40k/400k/4M/40MΩ, ±1.0%. CAP: 51.2n/512n/5.12µ/51.2µ/100µF, ±3.0% Audible continuity: (<50Ω) & diode test Battery: 7.4V/1500mAh lithium, 6 hours Power consumption: <6W Dimensions & weight: 180x113x40mm, approx. 690g Accessories: AC adaptor, interface wire & software, probes DS1022M • 3 3/4 digital multimeter built with dual channel scope of 20MHz bandwidth, 320x240p colour LCD display • Waveform maths, auto and cursor ­measurement • True RMS, relative measurement • USB interface to computer • Ideal tool for use in Lab., school, ­factory, field work and home wiring ­repair, etc. SOLAR MODULE ANALYSER PROVA200 Analyser •Voltage range: 0-60VDC •Current range: 0-6A • I-V Curve test for solar cell • Maximum solar power (Pmax) search by Auto-scan (60V, 6A) • Maximum voltage (Vmaxp) at Pmax SAFETY GLOVES CUST.GI CE Approved VPG90 Test V 2500V PROVA300XP 5kV Printer • Maximum current (Imaxp) at Pmax • Voltage at open circuit (Vopen) • Current at short circuit • Calculation of efficiency (%) • Manual single point test User V 500V 1kV 7.5kV 10kV 17kV 20kV 30kV Size Code Code Code Code Code 8 GI2,5-8 GI5-8 GI10-8 GI20-8 GI30-8 9 GI2,5-9 GI5-9 GI10-9 GI20-9 GI30-9 10 GI2,5-10 GI5-10 GI10-10 GI20-10 GI30-10 11 GI2,5-11 GI5-11 GI10-11 GI20-11 GI30-11 26.5kV Accessories Protective plastic case for gloves Pneumatic Tester. This tester inflates the gloves and you can detect any perforation on the dielectric of the gloves CUST.GI VPG90 Insulated Rubber Carpet in 3 & 6mm thickness x 1 metre wide – priced per metre IRC-3 3mm x 1 metre (w). Voltage test 30000V, max use voltage 26500V MET IRC-3 TEST INSTRUMENTS, TOOLS & GENSETS Code Description 265 HIGH VOLTAGE TEST EQUIPMENT High Voltage Proximity Detector High Voltage Multifunction Phasing Sticks • Lightweight • Designed for maximum safety • Carry case included HP275 Description: The HP275 is a high voltage proximity ­detector. It has eight voltage detection settings from 240VAC to 275kVAC. The HP275 consists of an internal pickup sensor plate, a sensitivity selector, a visual and an audible annunciator. With the HP275, physical ­contact with electrical conductors is not ­necessary when testing for live lines. This tester works by proximity. Features: • 8 voltage settings: Test 240VAC, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV and 275kV. • High bright LEDs visual indication. • Sound indication. • Easy-to-prove method. • Self-test selection. • Uses 3 x 1.5V “D” batteries. • High impact nylon and rubber casing. • Non-contact work by proximity. • Compatible with most link sticks. • Light weight, robust & compact. • Water resistant for outdoor use. • Detects low voltage on any system. Code System Voltage Full Scale Voltage Maximum Voltage PC-7K PC-11K PC-22K PC-33K PC-44K 6.6kV 11kV 22kV 33kV 44kV 8kV 12kV 24kV 36kV 48kV 9kV 15kV 30kV 40kV 55kV Accessories Code (for all models) PC-BK PC-C1K PC-C2K Cone tips 30mm Specifications: Electrical Total resistance Neon threshold Neon fully lit @ Respond Time <1 sec PC-7K ±3.95MΩ 1.2kV 1.5kV Mechanical PC-11K ±6.78MΩ 1.2kV 1.5kV Description 90º bends (pair) 30mm cone tips (pair) 70mm cone tips (pair) 70mm PC-22K ±13.5MΩ 1.2kV 1.5kV PC-33K ±20.1MΩ 1.2kV 1.5kV PC-44K ±27MΩ 1.2kV 1.5kV Handle length 765mm 765mm 765mm 765mm 765mm Front end length 340mm 340mm 460mm 610mm 760mm Total length 1105mm 1105mm 1225mm 1375mm 1525mm Total weight ±1.2kg ±1.2kg ±1.3kg ±1.4kg ±1.5kg Handle material: Composite material with polyurethane Front end: Fibre glass wound tubing Environmental Operating temp.: -25°C to +55°C Operating humidity: 20 to 96% RH Short Circuiting and Grounding Short circuiting and grounding equipment for electrical cabinets and MV installations with universal contact clamps Code Description TEST INSTRUMENTS, TOOLS & GENSETS MT/BM-25 Standard type. lcc: 13,7kA eff / 0.25s With short circuit cables section MT/BM 25mm2 MT/BM-50 With short circuit cables section 50mm2 Icc: 13kA eff / 0.5s MT/BM-95 With short circuit cables section 95mm2 Icc: 24kA eff / 0.5s Certificate complies to the International Standard CEI EN 61230 (CEI IEC 1230) Fuse Extraction Rod EF30 EF30 Insulating Rod for fuse extraction and installation on systems with working voltages up to 30kV Phasing and Voltage Detector of MV Presence / Absence by Visual Signalling (Indoor Use) Code RMB36 RMB36 c/w case 266 MET Description • Double poles voltage detector • Phase relationship detector • HV fuse tester • Operating range: 5/36 kV • Total length of each rod complete with antenna: 1,17m DIGITAL/ANALOG MULTIMETERS Digital Clamp Meter Digital Insulation Tester Hand Crank Insulation Tester Analogue/Digital Insulation Tester Analog Earth Resistance Tester PSE-266F PSE-261 KC-60B • AC Current: 1000A • DC Volts: 1000VDC • AC Volts: 750VAC • Diode tester • Audible continuity • Frequency: 2Hz • Data hold • OHMS: 0-2MΩ • Accepts adaptor for insulation tester PSE-261 Plug-in Insulation Tester for 266 Series Clamp Meter Rated voltage: 500V DC Ranges: 20MΩ, ±2.0% 2000MΩ, ±4.0% • Zero Adjustment: automatic • Test Voltage: 500V • Rated Voltage: switchable • Insulation Resistance: 250V/500V/1000V, ±10% • OHM Meter: • Measuring Range: 0Ω to 500MΩ 0-500M/1000M/2000MΩ, res. 1MΩ • Basic Accuracy: ±4% +2dgt • Short Circuit Output: 1.7mA/ 1.7mA/1.4mA • Input Resistance: 2M/2M/ 5MΩ RCD Tester TEL1-3 (230V) TEL1-4 (240V) • Verifies that the wiring is correct (Neon light indication) • RCD testing with variable fault current • Trip settings 10 - 35mA MiniTrip 1/L As MINITRIP 1 with 15A plug and lead. 150mA also available NB311110 2732IN Analog • 250V/100MΩ • 500V/200MΩ • 1000V/400MΩ • AC Volts: 600V/750VAC • Continuity Test: 0-100Ω/20, 200, 2kΩ • Timer 3 to 5 min • ± 5% F.S. accuracy • Auto off • Hold • Auto discharge • Battery operated (excl.) • Supplied with test leads • c/w carrying case Earth Leakage Testers MiniTrip 1 • Wiring check • 5-55mA Stepped output. Earth ­current test rated at 230VAC • 50/60Hz • Rotary switch selection • Push button injection MiniTrip 2 • Analogue • 10-50mA variable earth current • Wiring check • 50/60Hz • Potentiometer selection • 230VAC ±15% Uni-Trip 50/150 50 or 150mA range 3 phase Earth Leakage Tester ST-1505 • Earth resistance 10-100-1000Ω • Earth voltage: 0-30VAC • 800Hz ± 2mA • 6 x 1.5V batteries (excl.) • Supplied with test leads Loop/PSC/Earth H.V. Insulation 2820EL • Digital • Sensitivity test: 5-999mA (@ 317VL-E) • Time delay test: 0.000-99.999S • Sensitivity accuracy: ± 1mA • Time delay accuracy: ± 2ms • Multi-Voltage 100400VAC • 50Hz only • Auto-off MET 2751IN Digital 2726NA • Digital • Line impedance • Neutral impedance • Earth impedance • Voltage L-N • Voltage L-E • PSC L-N • PSC L-E • Scroll through results • 50Hz 230V ± 20% • Auto-ranging • Auto-off • c/w carrying case 2803IN 2804IN max 5kV max 10kV • 1kV, 2.5kV, 5kV, 10kV test voltage • ± 5% F.S. • Up to 500GΩ/10kV • 8 x 1.5V AA alkaline batteries (excl.) • Digital display • Timer • Bargraph • Auto-hold – Auto-off • Auto-discharge • Non isolated circuit sensing TEST INSTRUMENTS, TOOLS & GENSETS PSE-266F 267 DIGITAL CLAMP METERS Model Description Basic Accuracy Ranges AC Voltage DC Voltage True RMS AC AC Current DC Current Resistance Frequency MS2600 ST-330 AC current up to 400A AC Current up to 200A Data hold Data hold Peak hold Open jaw Easy to use ±2.5% rdg ± 4 dgt Diode test 200mV to 600V 200mV to 600V No 2A to 400A – 200Ω to 20Ω – 1000V 700V No 200A – 400Ω to 40MΩ 10kHz to 100kHz ST-9700 MS2026R AC/DC current up to 600A. Data Hold Buzzer for continuity test. Temperature -20°C to 1000°C. K-Probe (included) ±1.5% rdg ± 4 dgt AC current up to 1000A Data hold Peak hold Capacitance test 600nF to 100 µF ±1.5% rdg ± 5 dgt Diode test Auto ranging 0 to 700V 0 to 1000V Yes 0 to 1000A – 600V 200V No 200A/600A 200A/600A 0Ω to 2KΩ – 40Hz to 100KHz AC/DC Current Up to 1000A Autoranging Max, data/hold Buzzer for continuity ±1.2% rdg ± 3 dgt Diode test True RMS - 3810 only 0 to 600V 0 to 600V No Yes Up to 1000A Up to 1000A 0Ω to 200KΩ – Multi-Tester MS-2000G ST-600 • Analogue clamp meter. • AC current 0-600A • Pointer lock function • Range switch • Ω Range Basic Accuracy • AC current 2000A • Data hold • Frequency and temperature measurement • Clamp size 55mmØ • Auto power off • Diode and continuity check ±2.5% Ranges DC Voltage 1000V TEST INSTRUMENTS, TOOLS & GENSETS AC Voltage True RMS AC AC Current DC Current Resistance Frequency Temp 268 400mV to 700V 400mV to 1000V Yes 20A to 2000A 200A to 2000A 0Ω to 2KΩ 50-60Hz Capacitance Meter TES-1500 Description AC/DC Current up to 2000A. True RMS measure­ment. Frequency measurement. Relative reading ±1.9% rdg ± 5 dgt Diode test DIGITAL/ANALOGUE MULTIMETERS Clamp Meters Model BM2000B 3810 2605 ±3% of full scale 750V 150/300/600V No No 200/2000A – 2mΩ 20kHz 0-750°C – 6/30/60/300/600A – 0 to 2KΩ – – ST-365TRB • 3 colour and mirror scale • Safety fused • HFe and dB • ± 3% F.S. DC accuracy • ± 4% F.S. AC accuracy • DC mA 50µA, 2.5, 25, 250mA • Ω 2K to 20M • VAC/VDC 0 to 1000V • 20kΩ/Volt AC • 1kΩ/Volt DC Pocket Multimeter ST-112 • Pocket size • High speed auto­ranging • Bargraph • AC Volts: 500VAC • DC Volts:500VDC • OHMS: 40MΩ • Diode test • Capacitance: 200µF MET TES-1550 TES-1500 • 0.5% Accuracy • Overload Fuse protection • Test Clips/Direct insert jack for easy measurement Range: 200pF/ 2nF/ 20nF/ 2µF/ 200µF/ 2000µF/ 20mF Measurement Voltage 4.5V max. Test frequency 8/80/800Hz Principle Dual Stop Integration Zero Aro Adjustment ±20pF Approx. Automotive Meter TES-1550 • Engine RPM Measurement • Auto-power off • Water-proof ABS housing • Tacho: 10-10,000RPM (±2%rdg±1dgt) Dwell: %/4CYL/6CYL/8CYL DC/AC Current 40m/400m/20A DC/AC Voltage (±0.5%rdg±1dgt) 400m/4/40/400/750V(AC)/1000V(DC) Resistance 400/4k/40k/400k/4M/40MΩ Capacitance 4n/40n/400n/4µF/40µF Frequency 100/1k/10k/100k/500kHz DIGITAL MULTIMETERS Description MAS830 VC9808 MS8221A TES-2700 Large LCD Display Transistor test 6 Functions 19 ranges Great value! Last reading hold Large LCD Display Transistor test 7 Functions 24 ranges Great value! Last reading hold Auto-ranging Data hold Spraywater-protected Temp measures: -40 to 1000°C (Probe included) Peak hold Auto-ranging Data hold Spraywaterprotected Bargraph ±0.5% rdg ± 2 dgt ±0.5% rdg ± 2 dgt AC Voltage 100mV to 600V 1mV to 750V DC Voltage Diode Test AC Current DC Current Resistance Capacitance Frequency 100mV to 600V Yes – 0.1mA to 10A 0.1Ω to 2MΩ – – 0.1mV to 1000V Yes 1mA to 10A 0.1mA to 10A 0.1Ω to 20MΩ – – ±0.5% rdg ± 2 dgt 200mV to 700V (40 to 400Hz) 200mV to 1000V Yes 2mA to 20A 2mA to 20A 200Ω to 2000MΩ 20nF to 200µF 100Hz to 20MHz ±0.5% rdg ± 2 dgt 3.2V to 600V (40 to 400Hz) 320mV to 600V Yes 200µA to 20A 200µA to 20A 320Ω to 30MΩ – – Accuracy Ranges Code Description Accuracy Ranges AC Voltage DC Voltage Diode Test AC Current DC Current Resistance Capacitance Frequency Continuity Test ST-992 ST-2009 ST-9918 MS8226T True RMS Auto Ranging Data hold LCD backlit RS232C interface to computer Temp: -20°C to 1000°C ±0.5% rdg ± 1 dgt 400mV to 700V 400mV to 1000V Yes 400µA to 10A 400A to 10A 400Ω to 40MΩ 40nF to 100µF 4Hz to 40KHz ST-9932FC Auto Ranging Data Hold Auto Power off Max hold Temp measuring to 760°C K-Probe (included) Auto Ranging Data Hold Auto Power off Temp measuring to 760°C K-Probe (included) Min/Max recording mode Auto Ranging Temp measuring to 760°C K-Probe (included) Data Hold Auto Ranging Data Hold Auto Power off Temp measuring to 1000°C K-Probe (incl) With RS-232 cable and Software interface to computer 0.5%rdg + 2dgt 600V 600V Yes 10A 10A 2MΩ – – Yes 0.5%rdg + 2dgt 700V 1000V Yes 20A 20A 40MΩ 100f 9.999MHz Yes ±0.5%rdg + 2dgt 600V 600V Yes 10A 10A 40MΩ 200f 10MHz Yes 0.8%rdg + 3dgt 750V 1000V Yes 20A 20A 40MΩ 100f 9.999MHz Yes MET MY980 True RMS Spraywaterprotected Data hold ±0.5% rdg ± 1 dgt 400mV to 700V (40 to 1000Hz) 400mV to 1000V Yes 2mA to 10A 2mA to 10A 200Ω to 200MΩ 2000PF to 20µF 20KHz MS8264 • 30 ranges, 3 1/2 digits LCD display • AC voltage ­detection with LED indicator • Enhanced protection on all ranges: 200mA selfresume fuse, 1000V ­discharge capacitors, PTC, metal board shielding • Data hold and new LCD ­illumination • Temp: -40°C-1000°C 0.8%rdg + 3dgt 2V to 750V 200mV to 1000V Yes 10A 10A 200MΩ 200f 200KHz Yes TEST INSTRUMENTS, TOOLS & GENSETS Model 269 Multimeter True RMS & Data Logger DIGITAL MULTIMETERS AC/DC Power Clamp Meter PC Adaptor and Software For 3 phase/3 wires (balanced & unbalanced) power measurement (included) PROVA 803 PROVA 901 • Dual Input Channels • Dual Channels Measurement similar to a Dual Channels DSO (V+V, V+A) • Hz+Duty Cycle Dual Display • Standalone Data Logging of 10 708 Records both Channels • RS-232C Interface, application software (option) • The New Standard of DMM • Bandwidth 10kHz (max.) • Basic Accuracy 0.04% (DC) and 0.2% (AC) – DCV/ACV: 60.000mV-1000.0V – DCA/ACA: 600.00µA-10.000A – Resistance: 999.99Ω-40.000MΩ – Capacitance: 60.00nF-600.0µF – Frequency: 1.000Hz-2mHz – Duty-Cycle and Diode Test • Dual Input Channels • Compare Voltage at two different locations • Read Voltage and Current at the same time • Optical Isolated RS-232C ASCII Interface • True RMS • The New Standard of DMM • Bandwidth 200kHz • Basic Accuracy 0.02% (DC) and 0.1% (AC) – DCV/ACV: 60.000mV-1000.0V – DCA/ACA: 600.00µA-10.000A – Resistance: 999.99Ω-40.000MΩ – Capacitance: 60.00nF-600.0µF – Frequency: 1Hz-2.000kHz – Duty-Cycle and Diode Test Phase Sequence Indicator Digital Phase Indicator TES-3063 (c/w software) • 1600 Point Data logging function • True Power/Apparent Power/Power Factor Measurement • True RMS. V, A, W • 4 digits with 2” LCD Display • MIN/MAX/AVG Measurement • Amp/Voltage Frequency Measurement • PEAK HOLD Detector • 3 Phase adaptor for 3 phase power ­measurement • Peak hold/Data hold Range • True Power: 600kW (AC/DC) • Apparent Power: 600kVA (AC/DC) • Power factor: 0.3-1 Capacitive 0.3-1 Inductive -72.5° -0- +72.5° UPT/SPT Cable Tester Network Cable Tester TES-3064 (PC adaptor) • To down load the data into the ­computer from datalogging memory of TES-3063 • Communicates with PC via RS-232 for ­further data analysis and reports RS232/485 • DC/ACA: 1000A • OHM: 10KV • Continuity: below 100V • Hz: 1Hz -300KHz Cable/Wire Tracer Multi-Network Cable Tester TEST INSTRUMENTS, TOOLS & GENSETS Cat 5E, Cat 6, BNC Cable Tester ST-850 • Check phase sequence • Open phase check • 90-600VAC range • 50/60Hz • -10°C – +40°C operating • 540g (no battery required) • Instruction manual • Carrying case • Intermittent rated 270 SSP-8030 • Designed to check the ­presence of open phase and phase sequence by LED and buzzer at the same time Specifications • Operational Voltage: 200480V AC three phase • Time limit for continuous use: 60 minutes max. at 200V AC. 4 minutes max. at 480V AC • Frequency range: 20Hz-400Hz • Accessories: double­ ­insulated cords, probes for test leads KT-200 • Test UTP and STP wiring of T568A, T568B, 10Base-T, 100Base-T and Token ring ­network • Tests for open circuits, shorts, miswires, reversals, split pairs and cable’s shield integrity • DEBUG mode quickly identifies which cable pairs have a ­specific wiring fault • Warning: do not use on live ­circuits Cable length specifications • Minimum UTP/STP cable length for testing – 1 metre • Maximum UTP/STP cable length for testing – 200 metres MET KT-201 • Length test range 300m • Accuracy ±5% • Resolution 0.1m • 16 x 2 LCD characters • Cable continuity • Suitable for computer network systems • Warning: Do not use on live circuits MS6812 • Designed to identify and trace wires or cables within a group without damaging the insulation • Continuity test • Volume control for increased sensitivity • Recessed ON/OFF ­button to prevent battery drain Specifications • Emitter tone frequency: 1.5kHz • Receiver frequency range: 100-300kHz MS6810 • Designed to autoscan the wires of Ethernet (BNC/TNC) AT&T258A, EIA/ TIA568 token ring & modular cables • Auto checks for open circuits, shorts, misplaced wires & reversals • Tester designed for testing before or after cables have been installed • Quick & easy fault detecting VOLTAGE TESTERS 901 Double Pole Voltage Detector • Solenoid indication for AC and DC voltage readings. • Black makrolon case, oil-proof and non-burnable rubber grips with ­elastic finger guards. • Neon indication for voltage present and bright indicator scale for voltage range. Specifications • DC Voltage: 120-220-440-750V • AC Voltage: 125-220-380-500-750V • Cable: 1m in length • Construction: Handles are double insulated against electricity and heat MV-400 MV-4 • Test Voltage AC/DC: 6-400VAC/DC • Polarity test • Max. Testing Time: 30 sec BESTEST 8 • Test Voltage 12-600VAC/DC • LED indication 12-24-50-120-230400-600V • Max operating time: 30 sec • High voltage insulated 1000V Voltage Finders • Testing Voltage AC & DC: 6-400VAC/DC • Phase indication via LED (symbol ‘R’) • Polarity via LED • Test Earth Leakage CB via F1 ­push ­button • Continuity and semiconductor test 0-1MΩ • Max. Testing Time: 30 sec MS8211 • DC V: 600V • Auto Ranging • Data/max value hold • AC V: 600V • Diode Test • OHM: 200Ω to 20MΩ • Non-contact AC voltage detection with flashlight AC-9 • 100-600VAC • Rugged double moulded case • Built-in bright flash light • Flashing red LED indication Battery Testers M38900 • 90-600VAC 50/600Hz • Easy to use, just touch the tip to an outlet or cord, when it glows red, you know there’s voltage • Fits in your pocket • 2xAAA bat(incl.) BESTEST 7 • AC Voltage: 100-250VAC AT-953 MV-2 • AC Voltage: Contact Test 70-500VAC • Non Contact Test: 70-600VAC • DC Volts Test: Up to 2500VDC • Continuity Check: 0-50M Ohm • Microwave leakage detection, 5mW sq cm • Battery Tester • Plugs into car lighter • 5 indicators: Low/Fair/Normal/Full & Over • Battery and Alternator Tester • Alternator (engine ON): High – 15.0V Normal – 140V Low – 13.5V • Battery (engine OFF): Normal – 12.5V Low – 12.0V Flat – 5.0V • Max operating period: 10 sec Professional cable locator BT-12 BT-6 • 3 in 1 Battery/Bulb/Fuse tester • To test batteries type: AA, AAA, C, D, 9V, E, I, SV and PV Magnetic Field Tester Automotive Current Tester Maxi-Blade LA-1012 • Can trace cable in wall & underground • Tracing cable depth: 0-2.5m • Detects faults in cables and under-floor heating • Can trace metallic water & heating pipes • Receiver incl. torch • Digital signal ensures clear signal identification • Can be used on live or dead cables • 2 x 9V Battery included AC-8M • Testing of solenoids and relays • The test lamp illuminates when a magnetic field is present • No metallic contact is required • Responds to AC and DC magnetic fields and permanent magnets CF-02 Circuit Breaker Identifier Mini-Blade CF-02S • Measuring range: 20A @ 48VDC/ AC (10sec. max) • Resolution: 10mA • Cable length: 75cm • Plugs straight into automotive fuse holder in car MET • 12VDC Battery Analyser • Voltage Test 8-25VDC • On load battery test. This test evaluates the battery’s ability to crank an engine • Charging system test • Starter motor test 191CBI Easy tool to find the C/B or Fuse without disconnecting the supply. Plug the transmitter into the outlet socket, use the receiver to scan the C/B Panel to find the correct C/B ­supplying power to the socket TEST INSTRUMENTS, TOOLS & GENSETS BESTEST 18 271 DIGITAL METERS Infrared Thermometers Code Humidity & Temp Meters ST-8818 -50°C to 550°C -58°F to 1022°F 0.1° up to 200° Resolution: 1° over 200° ±1.5% of reading or ±2°C/ Basic Accuracy: ±4°F (whichever is greater) Optical Resolution: 12:1 Distance to Spot size Fixed at 0.95 Emissivity: 9V Battery (Incl.) Battery: • Laser targeting Features: • Automatic Data hold • Auto Power Off • User selectable °C or °F • Response time: 1 sec Laser & Probe IR-88 ST-616CT -20°C to 270°C -4°F to 518°F ST-8860 -20°C to 1000°C -4°F to 1832°F 0.1% RH 0.1° to 200° 1°>200°C -50°C to 1300°C -58°F to 2000°F 0.1% RH 0.1°C/1°C ±2% or ±2°C/±4°F ±3% ±0.5% + 1d 6:1 Fixed at 0.95 1.5V AAA Battery x 2 (Incl.) • Laser targeting • Data & max hold • Auto Power Off • User selectable °C or °F • Low Battery indication • Response time: 1 sec K-Type Probe included 9V Battery (Incl.) • Laser targeting • Large LCD with dual display • Max & hold function • Auto Power Off • Low Battery indication K-Type Probe included 9V Battery (Incl.) • Large display • Max & hold function • Auto Power Off • Low Battery indication Range: K Type Thermocouple Probes Pocket size 1°C/°F Laser Tachometer Digital Sound Level Temperature Meters ST-610B ST-612 -50°C to 1300°C -58°F to 2000°F 0.1°C or 1°C/°F ± 1°C K-Type Probe included 9V Battery (Incl.) • Large display • Data & max hold • (T1-T2) modes Freezes Display for ­convenient viewing (306) Lightmeter Anemometer Laser & contact TEST INSTRUMENTS, TOOLS & GENSETS DT-2236 • Non Contact RPM using reflecting tape and contact measuring • Contact measurement TPK-04 TPK-03 TPK-01 • 5 Digit LCD display • Auto range, from 10.0 to TPK-01 Bead Probe Measures surface or air ­temperatures to 260°C 99.999RPM (500°F). 1.2m long wire has an indus- • Measuring distance max try ­standard ­miniature connector plug. 2metres TPK-03 Immersion Probe • Resolution: General ­purpose ­needle type with 0.1RPM (<1000RPM) stainless sheath. Use for 1.0RPM (≥1000RPM) ­measurements up to 800°C (1472°F) • Memory recall button TPK-04 Surface Probe Miniature, • Accuracy: ± 0.05% fast response probe, with 800°C • Accessories: Reflecting (1472°F) max. surface temperature. strips Ideal for measuring the surface tem• 4 x 1.5V AA batteries (Incl.) perature of small electronic parts. 272 ST-8850 MS-6610 AVM-01 • 0.1dB Resolution • Range from 35 to 130dB • Maximum hold function • A & C frequency weightings • Fast & Slow dynamic ­characteristic models • Analogue AC/DC output for connection to an analyzer or recorder • T ypical instrument frequency range: 31Hz to 8KHz • Accuracy ±1.5dB • Time weighting: Slow and Fast • Maximum hold: Delay<1dB/3min • Microphone: Electric ­condenser microphone Features: • Cosine Angular ­corrected • Analogue output jack for recording (1332/1334) • Data hold function. Range (±3%rdg ±0.5%f.s) 200/2000/20000/50000 Lux 20000 lux-reading x 10; 200000 lux-reading x 100 Over-range Display: Highest digit of (1) is ­displayed Features: • Measures wind speed & direction • Backlight • Size: 208 x 72mm vane head Range (±2%rdg±0.1) M/S: (Metre/per Sec.) 0.4- 30.0 KNOTS: 0.8-58.3 Ft/s: 2-98.5 Km/H: 1.4-108.0 Display: Large 3 1/2 digit LCD • 1 x 9V Battery (Incl.) • Auto power off • Data hold function MET