SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 SIMCO ELECTRONICS 1665 West Quincy Avenue, Suite 103 Naperville, IL 60540 Kevin Summey Phone: 630 717 1800 CALIBRATION Valid To: September 30, 2018 Certificate Number: 1395.07 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations1: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 5, 6 () Comments DC Voltage3 – Generate (0 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V 16 V/V + 1 V 8.6 V/V + 2 V 9.4 V/V + 20 V 14 V/V + 150 V 17 V/V + 1.5 mV Fluke 5520A/SC600 DC Voltage3 – Measure (0 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V* 6.5 V/V + 0.36 V 4.7 V/V + 0.36 V 4.7 V/V + 0.6 V 7.3 V/V + 0.36 V 7.9 V/V + 110 V* HP 3458A opt 2 (0 to 330) A (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 11) A (11 to 20.5) A 0.021 % + 0.02 A 0.0079 % + 0.05 A 0.015 % + 0.25 A 0.013 % + 2.5 A 0.016 % + 40 A [1] 0.13 % + 500 A [1] 0.17 % + 750 A Fluke 5520A/SC600 DC Current3 – Generate A2LA Cert. No. 1395.07) 07/22/2016 *add 12 (Vin/1000)2 parts in 106 to all Vin > 100 [1] Floor specification doubled after 30 seconds Page 1 of 10 Range CMC2, 4, 5, 6 () Comments DC Current3 – Measure (0 to 1) µA (1 to 10) µA (10 to 100) A (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 0.059 % + 48 pA 66 A/A + 120 pA 27 A/A + 0.96 nA 26 A/A + 6 nA 26 A/A + 60 nA 42 A/A + 0.6 A 0.013 % + 12 A HP 3458A, opt 2 Resistance3 – Generate (0 to 11) (11 to 33) (33 to 110) (110 to 330) (0.33 to 1.1) k (1.1 to 3.3) k (3.3 to 11) k (11 to 33) k (33 to 110) k (110 to 330) k (0.33 to 1.1) M (1.1 to 3.3) M (3.3 to 11) M (11 to 33) M (33 to 110) M (0.11 to 1.1) G 40 / + 1 m 64 / + 1.5 m 22 / + 1.4 m 29 / + 2 m 22 / + 2 m 31 / + 0.02 22 / + 0.02 25 / + 0.2 22 / + 0.2 44 / + 2 28 / + 2 0.027 % + 30 0.011 % + 50 0.028 % + 2.5 k 0.042 % + 3 k 1.2 % + 500 k Fluke 5520A/SC600 Resistance3 – Measure (0 to 10) (10 to 100) (0.1 to 1) k (1 to 10) k (10 to 100) k (0.1 to 1) M (1 to 10) M (10 to 100) M (100 to 1000) M 30 / + 50 14 / + 0.5 m 12 / + 1 m 12 / + 10 m 12 / + 0.6 18 / + 3 60 / + 120 0.059 % + 1.2 k 0.58 % + 12 k HP 3458A, opt 2 Parameter/Equipment A2LA Cert. No. 1395.07) 07/22/2016 Page 2 of 10 Parameter/Equipment Capacitance – Generate Range (0.19 to 3.3999) nF (0.4 to 1.0999) nF (1.1 to 13.2999) nF (3.3 to 10.9999) nF (11 to 109.99999) nF (110 to 329.999) nF (0.33 to 1.9999) µF (2 to 3.2999) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.9999) µF (110 to 329.9999) µF (0.33 to 1.09999) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF CMC2, 4, 6 () 0.61 % + 7.8 pF 0.44 % + 7.8 pF 0.42 % + 7.8 pF 0.24 % + 7.8 pF 0.23 % + 7.8 pF 0.23 % + 0.24 nF 0.23 % + 0.8 nF 0.23 % + 2.3 nF 0.24 % + 7.8 nF 0.34 % + 23 nF 0.38 % + 78 nF 0.38 % + 230 nF 0.37 % + 0.8 µF 0.37 % + 2.3 µF 0.37 % + 7.8 µF 0.59 % + 23 µF 0.86 % + 78 µF Comments Fluke 5520A Oscilloscopes3 – Square Wave Signal 10 Hz to 10 kHz 50 Impedance 1 M Impedance Fluke 5520A/SC600 1 mV to 6.6 Vpk – pk 1 mV to 130 Vpk - pk 0.26 % + 100 V 0.13 % + 100 V 1 mV to 6.6 V 1 mV to 130 V 0.25 % + 40 V 0.052 % + 40 V 10 mV to 5 V(p-p) 2 % + 300 V 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 1.8 % + 100 V 1.8 % + 100 V 3.2 % + 100 V 2 ns to 20 ms (50 to 5) s 2.5 parts in 106 s (25 + 1000*t) s/s > 350 ps 160 ps DC Signal 10 Hz to 10 kHz 50 Impedance 1 M Impedance Level Sine Amp – 50 50 kHz Ref. Level Sine Flatness –50 5 mV to 5.5 V Relative to 50 kHz Ref. Time Marker – 50 Rise Time (1 to 10) MHz A2LA Cert. No. 1395.07) 07/22/2016 t = time in seconds Page 3 of 10 Parameter/Equipment Range CMC2 () Comments Electrical Simulation of Thermocouple Indicators and Indicating Systems3 – Type E -250 C to -100 C -100 C to -25 C -25 C to 350 C 350 C to 650 C 650 C to 1000 C 0.5 C 0.16 C 0.14 C 0.16 C 0.21 C Type J -210 C to -100 C -100 C to -30 C -30 C to 150 C 150 C to 760 C 760 C to 1200 C 0.27 C 0.16 C 0.14 C 0.17 C 0.23 C Type K -200 C to -100 C -100 C to -25 C -25 C to 120 C 120 C to 1000 C 1000 C to 1372 C 0.33 C 0.18 C 0.16 C 0.26 C 0.4 C Type T -250 C to -150 C -150 C to 0 C 0 C to 120 C 120 C to 400 C 0.63 C 0.24 C 0.16 C 0.14 C A2LA Cert. No. 1395.07) 07/22/2016 Fluke 5520A Page 4 of 10 Parameter/Range Frequency CMC2, 4, 6 () Comments AC Voltage3 – Generate (1 to 33) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.078 % + 6 V 0.049 % + 6 V 0.05 % + 6 V 0.1 % + 6 V 0.28 % + 12 V 0.66 % + 50 V (33 to 330) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.027 % + 8 V 0.018 % + 8 V 0.019 % + 8 V 0.032 % + 8 V 0.064 % + 32 V 0.16 % + 70 V (0.33 to 3.3) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.027 % + 8 V 0.018 % + 8 V 0.020 % + 8 V 0.027 % + 8 V 0.056 % + 32 V 0.19 % + 70 V (3.3 to 33) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.027 % + 0.65 mV 0.018 % + 0.6 mV 0.023 % + 0.6 mV 0.03 % + 0.6 mV 0.071 % + 1.6 mV (33 to 330) V 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.02 % + 2 mV 0.021 % + 6 mV 0.024 % + 6 mV 0.051 % + 6 mV 0.16 % + 50 mV (330 to 1020) V 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.024 % + 10 mV 0.02 % + 10 mV 0.024 % + 10 mV A2LA Cert. No. 1395.07) 07/22/2016 Fluke 5520A/SC600 Page 5 of 10 Parameter/Range Frequency CMC2, 5, 6 () Comments AC Voltage – Measure3 (1 to 10) mV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.06 % + 3 V 0.05 % + 1.1 V 0.06 % + 1.1 V 0.14 % + 1.1 V 0.58 % + 1.1 V 4.6 % + 2 V (10 to 100) mV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz 90 V/V + 4 V 90 V/V + 2 V 0.017 % + 2 V 0.036 % + 2 V 0.093 % + 2 V 0.35 % + 10 V 1.2 % + 10 V 1.6 % + 10 V (0.1 to 1) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz 0.013 % + 40 V 0.016 % + 20 V 0.017 % + 20 V 0.035 % + 20 V 0.092 % + 20 V 0.35 % + 100 V 1.2 % + 100 V 1.6 % + 100 V (1 to 10) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz 90 V/V + 0.4 mV 90 V/V + 0.2 mV 0.017 % + 0.2 mV 0.035 % + 0.2 mV 0.092 % + 0.2 mV 0.35 % + 1 mV 1.2 % + 1 mV 1.6 % + 1 mV (10 to 100) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.03 % + 4 mV 0.03 % + 2 mV 0.024 % + 2 mV 0.041 % + 2 mV 0.14 % + 2 mV A2LA Cert. No. 1395.07) 07/22/2016 HP 3458A, opt 2 Page 6 of 10 Parameter/Range Frequency CMC2, 4, 5, 6 () Comments AC Voltage – Measure3 (cont) (100 to 700) V (1 to 40) Hz 40 Hz to 1 kHz 0.05 % + 40 mV 0.05 % + 20 mV HP 3458A, opt 2 1 kHz 0.099 % + 0.1 A 0.078 % + 0.15 A 0.032 % + 2 A 0.032 % + 20 A 0.04 % + 0.1 mA 0.024 % + 0.1 mA 0.081 % + 2 mA 0.12 % + 5 mA Fluke 5520A/SC600; LCOMP off 1 kHz 0.075 % + 0.03 A 0.041 % + 0.2 A 0.041 % + 2 A 0.041 % + 20 A 0.12 % + 0.2 mA HP 3458A opt2 AC Current – Generate3 (30 to 330) A (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A AC Current – Measure3 (5 to 100) A (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A II. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 6 () Comments Amplitude Modulation – Measure Rate: 50 Hz to 10 kHz Depth: (5 to 99) % 150 kHz to 10 MHz 2.5 % + 1 digit Rate: 20 Hz to 10 kHz Depth: Up to 99 % 150 kHz to 10 MHz 3.6 % + 1 digit A2LA Cert. No. 1395.07) 07/22/2016 HP 8902A measuring receiver w/ 11722/92A sensor & 11793 mixer Page 7 of 10 Parameter/Range Frequency CMC2, 6 () Comments Amplitude Modulation – Measure (cont) Rate: 50 Hz to 50 kHz Depth: (5 to 99) % > 10 MHz to 1.3 GHz 1.5 % + 1 digit Rate: 20 Hz to 100 kHz Depth: Up to 99 % > 10 MHz to 1.3 GHz 3.6 % + 1 digit Rate: 50 Hz to 50 kHz Depth: (5 to 99) % > (1.3 to 26.5) GHz 1.7 % + 1 digit Rate: 20 Hz to 100 kHz Depth: Up to 99 % >(1.3 to 26.5) GHz 3.5 % + 1 digit Rate: 20 Hz to 10 kHz Dev: ≤ 40 kHz 250 kHz, 10 MHz 2.4 % + 1 digit Rate: 50 Hz to 100 kHz Dev: ≤ 400 kHz 10 MHz to 26.5 GHz 1.2 % + 1 digit Rate: 20 Hz to 200 kHz Dev: ≤ 400 kHz 10 MHz to 26.5 GHz 2.4 % + 1 digit Rate: 200 Hz to 10 kHz 150 kHz to 10 MHz 4.0 % + 0.023 rad Rate: 20 Hz to 200 kHz 10 MHz to 26.5 GHz 5.0 % + 0.028 rad (0.02 to 20) kHz (20 to 100) kHz 1.2 dB 2.4 dB HP 8902A measuring receiver w/ 11722/92A sensor & 11793 mixer Frequency Modulation – Measure HP 8902A measuring receiver w/ 11722/92A sensor & 11793 mixer Phase Modulation – Measure HP 8902A measuring receiver w/ HP 11792A sensor Distortion – Measure (0 to -80) dB A2LA Cert. No. 1395.07) 07/22/2016 HP 8903B Page 8 of 10 Parameter/Range Frequency CMC2 () Comments Tuned RF Power – Measure (+10 to 0) dBm (<0 to -10) dBm (<-10 to -20) dBm (<-20 to -30) dBm (<-30 to -40) dBm (<-40 to -50) dBm (<-50 to -60) dBm (<-60 to -70) dBm (<-70 to -80) dBm (<-80 to -90) dBm (<-90 to -100) dBm (<-100 to -110) dBm 100 kHz to 1.3 GHz 0.11 dB 0.11 dB 0.12 dB 0.14 dB 0.15 dB 0.16 dB 0.18 dB 0.21 dB 0.23 dB 0.25 dB 0.27 dB 0.29 dB (+10 to 0) dBm (<0 to -10) dBm (<-10 to -20) dBm (<-20 to -30) dBm (<-30 to -40) dBm (<-40 to -50) dBm (<-50 to -60) dBm (<-60 to -70) dBm (<-70 to -80) dBm (<-80 to -90) dBm (<-90 to -100) dBm (<-100 to -110) dBm > (1.3 to 18) GHz 0.11 dB 0.11 dB 0.12 dB 0.13 dB 0.15 dB 0.16 dB 0.19 dB 0.21 dB 0.23 dB 0.25 dB 0.27 dB 0.29 dB (+10 to 0) dBm (<0 to -10) dBm (<-10 to -20) dBm (<-20 to -30) dBm (<-30 to -40) dBm (<-40 to -50) dBm (<-50 to -60) dBm (<-60 to -70) dBm (<-70 to -80) dBm (<-80 to -90) dBm (<-90 to -100) dBm (<-100 to -110) dBm > (18 to 26.5) GHz 0.11 dB 0.11 dB 0.11 dB 0.13 dB 0.15 dB 0.16 dB 0.18 dB 0.21 dB 0.23 dB 0.25 dB 0.27 dB 0.29 dB A2LA Cert. No. 1395.07) 07/22/2016 HP 8902A measuring receiver w/ 11722A sensor Page 9 of 10 III. Time & Frequency Range Parameter/Equipment Frequency – Measuring Equipment3 10 MHz CMC2 () 10 pHz/Hz Comments Fluke 910 GPS receiver ___________________________________________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 – General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Based on using the standard at the temperature the Fluke 5520A with SC600 was calibrated (tcal ± 5 °C) and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5 °C. For resistance, a zero calibration is performed at least every 12 hours within ± 1 oC of use. 5 Based on using the standard at the temperature the HP 3458A was calibrated (tcal ± 5 °C) and an autocalibration (ACAL) was performed within the previous 24 hours (± 1 °C of ambient). 6 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted. A2LA Cert. No. 1395.07) 07/22/2016 Page 10 of 10 Accredited Laboratory A2LA has accredited SIMCO ELECTRONICS Naperville, IL for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of ANSI/NCSLI Z540-1-1994 and any additional program requirements in the field of calibration. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILACIAF Communiqué dated 8 January 2009). Presented this 22nd day of July 2016. _______________________ Senior Director of Quality and Communications For the Accreditation Council Certificate Number 1395.07 Valid to September 30, 2018 For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.