Low Voltage Products Change-over and transfer switches Rotary change-over and bypass cam switches 16...1600 Amps Change-over switches IEC lth /A le /AC-22A, < 415V le /AC-23A, < 415V IEC lth /A le /AC-22A, < 415V le /AC-23A, < 415V IEC lth /A le /AC-22A, < 415V le /AC-23A, < 415V OT16E OT25E OT32E 25 32 16 25 16 20 40 40 23 OT45E OT63E OT125E 63 63 45 125 125 90 80 80 75 OT160E OT200E OT250E 160 200 250 160 200 250 160 200 250 OT160E_W OT200E_W OT250E_W 160 200 250 160 200 250 160 200 250 OT315E OT400E OT630E OT800E 315 400 315 400 315 400 630 800 630 800 630 800 OETL100K OETL1250K OETL1600K 1000 1000 800 I S01575A II NO I O OFF Accessories O OFF NO I 2 Optional handles Extended shafts Auxiliary contacts Terminal shrouds Connecting accessories Locking accessories 1250 1250 800 1000 1600 800 Change-over switches Transfer switches Rotary change-over and bypass cam switches Contents: Open transition switches Modular change-over switches OT 16...125 Technical data .......................................................................................................................... 7 Ordering information ........................................................................................................ 8 - 10 Modular change-over switches ............................................................................................. 8 Accessories .................................................................................................................... 8 - 10 Contact functions .................................................................................................................. 10 Dimension drawings ............................................................................................................. 11 Change-over switches OT 160...800, OETL 1000...1600 and OEM 200...1600 Technical data and operation functions ....................................................................... 13 - 15 Ordering information ...................................................................................................... 16 - 23 Change-over switches , manual operation ....................................................................16 - 17 Change-over switches , motor operation ......................................................................18 - 19 Accessories ...................................................................................................................20 - 23 Contact functions .................................................................................................................. 23 Dimension drawings ...................................................................................................... 24 - 29 Transfer switches OETL-NFC 200...1200, UL approved Technical data ........................................................................................................................ 31 Ordering information ...................................................................................................... 32 - 33 Change-over switches .......................................................................................................... 32 Accessories ......................................................................................................................... 33 Contact functions ................................................................................................................. 34 Dimension drawings ...................................................................................................... 34 - 35 Closed transition switches Transfer switches OESC 250...500 Technical data and contact functions .................................................................................. 37 Ordering information ............................................................................................................. 38 Transfer switches ................................................................................................................. 38 Accessories ......................................................................................................................... 38 Dimension drawings ............................................................................................................. 39 Rotary cam switches Rotary change-over and bypass cam switches OM, ON and OL 40...200 Technical data ................................................................................................................. 41 - 42 Ordering information ...................................................................................................... 43 - 50 Change-over switches, OM, ON and OL ...................................................................... 43 - 45 Bypass switches, ON and OL.............................................................................................. 46 Accessories .................................................................................................................. 47 - 50 Dimension drawings ...................................................................................................... 51 - 53 3 1SKC000006C0201 Secured power supply to diverse applications I II ◆ Change-over switch ◆ Change-over cam switch Special switches for secured power supply The complex systems of distributing power in emergency cases are often controlled by logics, with mechanical devices for making & breaking, conducting and isolating power. On the other hand, the loads may need to be transferred from one supply to another. This is the case when the use of energy is restricted, when the supplying source A secured power supply to diverse applications, from computers to industrial processes, is more and more important as the optimizing of costs for lack of production and maintenance is crucial for a successful business. is overloaded or when maintenance is required. Our solution for these installations are change-over or transfer switches with remote control by motor operator or manual local operation. The range consists of switches, mechanically interlocked to each other, with electrical characteristics that allow an onload switching between the two supplies. The isolation of the primary and secondary circuits is assured by the positive contact opening function and the reliable position indication. The switches can also be built by using available mechanism kits and standard switch-disconnectors. To meet the demands from different markets the change-over switches are tested according to IEC and UL and certified by KEMA. ◆ Closed transition switch Tested according to IEC 60947-6 Utilization categories: AC-31 for non-inductive or slightly inductive load, AC-33 for motor loads or mixed loads including motors. 4 The tests are performed for frequent, suffix A, and infrequent, suffix B, operations. The endurance requirements for a change-over application between two power circuits under load is normally met only by a lifetime fulfilling IEC 60947-6. ◆ Local operation ◆ Closed transition switches for ◆ Change-over switches UPS applications The closed transition transfer switch is a “make before break” switch type which guarantees a transfer of the supply without any interruption. The switch is equipped with overlapping positions I - II. The change-over switch is equipped with three stable positions and is independent of external supply, in operations there is no risk of an unexpected opening of the switch due to loss of supply voltage and no supply voltage is necessary to keep the switch in the closed position. Two operation options Manual operation: using a handle fixed directly onto the switch, to the panel board or to the door of the panel board. This type of operation extends the operation time between the two supplies. Motorised operation: no human participation is needed for the intervention, and consequently the operation time between the normal and the alternate supply is short. Example of electrical (I= 315 A) lifetime test: Number of operating cycles Suffix A Suffix B I Test [A] Operating cycle 315 O-I-O 630 O-I-O-II-O IEC 60947-3 AC-23 1000 200 IEC 60947-6 AC-33 4000 1000 ◆ Remote control 5 Open transition switches Modular change-over switches The change-over switch carries out the switching and the reliable isolation between the primary network supply and the alternate supply, thus ensuring the continuity of performance. The modular change-over switch range OT16...125 offers a most compact solution. The space requirements for a change-over switch is the same as for the switch-disconnectors next to each other. Only in depth it needs 11 mm in addition. It is easy to install: mounting onto 35 mm DIN-rail and it’s suitable for 45 mm cut-outs for consumer units. 6 Modular change-over switches Technical data Data according to IEC 60947-3 Switch size OT16_ OT25_ OT32_ OT45_ OT63_ OT125_ ............................................................................................ Rated insulation voltage and rated operational voltage AC20/DC20 Pollution degree 3 50 Hz 1min. Dielectric strength Rated impulse withstand voltage V 750 750 750 750 750 750 kV kV 6 8 6 8 6 8 6 8 6 8 6 8 Rated thermal current and rated operational / ambient 40°C In open air A 25 32 40 63 80 125 current AC20/DC20 / ambient 40°C In enclosure A 25 32 40 63 80 125 / ambient 60°C In enclosure A 20 25 32 50 63 100 Cu up to 500 V 690 V up to 500 V 690 V up to 415 V 440 V 500 V 690 V mm2 A A A A A A A A 4 16 16 16 16 16 16 16 10 6 25 25 25 25 20 20 20 11 10 40 40 40 40 23 23 23 12 16 63 63 63 63 45 45 45 20 25 80 80 80 80 75 65 58 20 50 125 125 125 125 90 78 70 50 230 V 400 V 415 V 500 V 690 V up to 415 V 440 V 500 V 690 V 50 kA, 415 V gG/aM 100 kA, 500 V gG/aM kW kW kW kW kW A A A A kA A/A kA A/A 3 7.5 7.5 7.5 7.5 128 128 128 80 6.5 40/32 4 9 9 9 9 160 160 160 88 6.5 40/32 5,5 11 11 11 11 184 184 184 96 6.5 40/32 11 22 22 22 15 360 360 360 160 13 100/80 17 100/80 22 37 37 37 18.5 640 448 464 160 13 100/80 17 100/80 22 45 45 45 45 720 624 560 400 16.5 125/125 690 V 0.15s 690 V 0.25s 690 V 1s 690 V kA kA kA kA 0.5 0.7 0.5 0.7 0.5 0.7 1 1.4 1.5 2.1 2.5 3.6 ..with minimum conductor cross section Rated operational current, AC-21A Rated operational current, AC-22A Rated operational current, AC-23A Rated operational power, AC-23A 1) The kW-ratings are accurate for 3-phase 1500 R.P.M. standard asychronous motors Rated breaking capacity in category AC-23 Rated conditional short-circuit current Ip (R.M.S.) and corresponding max. allowed cut-off current îc peak value. The cut-off current îc refers to values listed by fuse manufacturers (single phase test acc. to IEC60269). Ip (R.M.S.) Max. OFA_ fuse size Ip (R.M.S.) Max. OFA_ fuse size Rated short-time withstand current R.M.S. value Icw Rated short-time making capacity Peak value Icm Mechanical endurance Divide by four for oper. cycles 2) Oper. 20000 20000 20000 20000 20000 20000 Cable size Cu-wire size suitable for terminal clamps mm2 0.75-10 0.75-10 0.75-10 1.5-35 1.5-35 10-70 Terminal tightening torque Counter torque required AWG Nm 18-8 0.8 18-8 0.8 18-8 0.8 14-4 2 14-4 2 8-00 6 Operating torque Typical for 3-pole switch-disconnector Nm 1 1 1 1.2 1.2 2 Weight without accessories 3-pole switch kg 0.25 0.25 0.25 0.64 0.64 0.90 4-pole switch kg 0.31 0.31 0.31 0.70 0.70 1.18 A HP HP HP HP HP 16 3 3 5 10 10 25 7.5 7.5 7.5 15 20 40 10 10 10 20 25 60 15 15 15 30 30 80 20 20 20 40 40 Data according to UL508 (Listed) Current Horsepower, 3-phase 1) 2) 200 V 208 V 240 V 480 V 600 V These values are given for guidance and may vary acc. to the motor manufacturer. Operating cycle: O - I - O - II - O 7 1SKC000006C0201 Modular change-over switches Ordering information S01415A Modular change-over switches, 3 pole, I-O-II -operation, open transition Include terminal clamps, IP20. Handle and shaft has to be ordered separately. OT 16...63 are UL Listed. I ON I ON O OFF O OFF S01295A OT16E3C Rated current / Rated power AC-21A...AC-22A Up to 415V 400V I[A] S[kVA] AC-23A 400...415V I[A] / P[kW] 16 25 40 63 80 125 16/7.5 20/9 23/11 45/22 75/37 90/45 11 17 27 43 55 86 Cable cross section Type Order number Weight [kg] OT16E3C OT25E3C OT32E3C OT45E3C OT63E3C OT125E3C 1SCA022605R8870 1SCA022605R9920 1SCA022605R9410 1SCA022551R3880 1SCA022551R6210 1SCA022551R8680 0.25 0.25 0.25 0.64 0.64 0.90 [mm2] 0.75 … 10 0.75 … 10 0.75 … 10 1.5 … 35 1.5 … 35 10 … 70 Modular change-over switches, 4 pole, I-O-II -operation, open transition OT45...63E3C Include terminal clamps, IP20. Handle and shaft has to be ordered separately. OT 16...63 are UL Listed. I ON S01296A I ON O OFF O OFF OT125E3C Rated current /Rated power AC-21A...AC-22A Up to 415V 400V I[A] S[kVA] AC-23A 400...415V I[A] / P[kW] 16 25 40 63 80 125 16/7.5 20/9 23/11 45/22 75/37 90/45 11 17 27 43 55 86 Cable cross section Type Order number Weight [kg] OT16E4C OT25E4C OT32E4C OT45E4C OT63E4C OT125E4C 1SCA022551R4770 1SCA022551R5580 1SCA022551R3110 1SCA022551R4340 1SCA022551R6390 1SCA022551R8760 0.31 0.31 0.31 0.70 0.70 1.18 [mm2] 0.75…10 0.75…10 0.75…10 1.5…35 1.5…35 10…70 Accessories Change-over kits The modular change-over switches can be built up by adding a compact snap-on kit on the top of two switch-disconnectors. The kits do not require any additional foot print area, only the height is increased 12 mm. S01282A ON ON O OFF O OFF F O OF I ON OWC5D3 II ON For switches For shafts Type Order number Weight [kg] OT16…32E OT45…80E OT100...125E OXS5_, OXP5_ OXS5_, OXP5_ OXS5_, OXP5_ OWC5D1 OWC5D2 OWC5D3 1SCA022551R9220 1SCA022574R8760 1SCA022574R8840 0.03 0.07 0.09 Auxiliary contacts S00261A Snap-on mounting to the switch, IP 20, max. 2 blocks/ side. Suitable for cable cross sections max. 2 x 2,5 mm2. See the contact functions, page 10. S01025A OA1G01 OA1G10 OA7G10 OA8G01 S00262A OA2G11 OTPS 8 1SKC000006C0201 For switches Contact functions Installation side Type Order number Weight [kg] OT16...125E_C OT16...125E_C OT16...125E_C OT16...125E_C OT45...125E3C 1NO 1NC 1NO 1NC 1NO+1NC Right Right Left Left Either OA1G10 OA8G01 OA7G10 OA1G01 OA2G11 1SCA022353R4970 1SCA022744R2240 1SCA022673R1140 1SCA022353R4890 1SCA022379R8010 0.03 0.03 0.03 0.03 0.03 4th poles Snap-on mounting to the left or right side of the switches, IP20. Simultaneous operation with power poles. For switches Rated current / up to 415V AC-21A /AC-22A AC-23A I[A] I[A] Type Order number Weight [kg] OT 16…32 OT 45…63 OT 125 40 80 125 OTPS32EP OTPS63EP OTPS125EP 1SCA022348R2480 1SCA022353R5350 1SCA022379R8010 0.03 0.06 0.14 23 75 90 Accessories Ordering information Handles and shafts S01368A Internal handles, IP20 No shaft needed, direct mounting on the top of the switch. S01369A OHR2 For switches Colour Non Padlockable padlockable in 0-position Type Order number Units/ Weight type [kg] OT16…63 Black Black Red Red Black Black Red Red Black Black Red Red Black Black Black Black Red Red x x x x x x x x x x x x OHB2/1 OHR2 OHR2/1 OHR2 OHB3/1 OHB3 OHR3/1 OHR3 OHB9/1 OHB9 OHR9/1 OHR9 OHB11/1 OHB11 OHB12/1 OHB12 OHR12/1 OHR12 1SCA022660R4540 1SCA022648R3810 1SCA022660R4620 1SCA022645R2420 1SCA022659R7400 1SCA022648R4110 1SCA022660R4710 1SCA022648R4200 1SCA022660R5010 1SCA022648R3900 1SCA022660R4970 1SCA022648R4030 1SCA022692R5690 1SCA022680R8970 1SCA022692R0540 1SCA022687R9810 1SCA022692R0620 1SCA022692R0460 1 10 1 10 1 10 1 10 1 10 1 10 1 10 1 10 1 10 S00535A OHR3 OHB9 S01473A OT125 OT125 OHB11 S01472A OT16…63 OHB12 x x x x x x 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.02 0.02 0.01 0.01 0.01 0.01 Selector type handles 0 OFF II ON S01520A I ON OHB2_ Selector handle, black IP65, Nema type 1, 3R, 12, indication I-O-II. Padlockable in O -position with maximum three padlocks with bail diameter 5...8 mm (two lower holes) and 5...6.3 mm (the upper hole). Door interlock in I- and II-position and when padlocked in O-position. For switches Colour Type Order number Weight [kg] OT16…125 OT16…125 Black Red-yellow OHB2AJE011 OHY2AJE011 1SCA022698R3710 1SCA022698R3890 0.07 0.07 S01026A Shafts for selector type handles For switches Length [mm] Diameter [mm] Type Order number Weight [kg] OT 16…125 85 105 120 130 5 5 5 5 OXS5x85 OXS5x105 OXS5x120 OXS5x130 1SCA022347R3570 1SCA022347R3650 1SCA022347R3730 1SCA022353R4540 0.03 0.03 0.04 0.04 OXS5x_ Pistol type handles, IP65 NO I O OFF The handles are equipped with door interlock function in both I- and II- position and when padlocked. Padlocking possibility in all positions with three padlocks, bail dia ∅ 5...10 mm. Indication I-O-II. Colour Type Order number Weight [kg] OT 16...125 Black Red-yellow OHB45J5E311 1SCA022615R1310 OHY45J5E311 1SCA022615R1490 0.1 0.1 NO I O OFF For switches Shafts for pistol type handles S00050B OH_ For switches Length [mm] Diameter [mm] Type Order number Weight [kg] OT 16…125 150 170 265 400 5 5 5 5 OXP5x150 OXP5x170 OXP5x265 OXP5x400 1SCA022376R7300 1SCA022376R7480 1SCA022376R7560 1SCA022376R7640 0.05 0.05 0.08 0.12 OXP5x_ 9 1SKC000006C0201 Accessories Ordering information , contact functions S00265A Terminal shrouds Snap-on mounting to the switches, IP20. The full shrouding of a 3-pole change-over switch is achieved with four 3-pole shrouds. Suitable for For three pole switches OT 16…32 OT 45…63 OT 125 For fourth pole OTPS 32EP OTPS 63EP OTPS 125EP S00462A OTS_T3 OTS_T1 Type Order number Weight [kg] OTS32T3 OTS63T3 OTS125T3 1SCA022353R6670 1SCA022353R6750 1SCA022379R9680 0.01 0.01 0.01 OTS32T1 OTS63T1 OTS125T1 1SCA022353R6830 1SCA022353R6910 1SCA022379R9760 0.01 0.01 0.01 Parallel connection kits S01469A Finger protected connection bars for parallel connection of the upper or lower terminals. The bars accept additional cables, the maximum size is stated below. S01470A OZXA 32 For switches Cable size [mm2] Type Order number Weight [kg] OT16…32E3C OT16…32E4C OT45…63E3C OT45…63E4C OT100…125E3C OT100…125E4C 6 (fine stranded), 10 (stranded) 6 (fine stranded), 10 (stranded) 25 25 50 50 OZXA33 OZXA32 OZXA38 OZXA39 OZXA40 OZXA41 1SCA022685R0310 1SCA022683R4110 1SCA022785R2140 1SCA022790R3820 1SCA022790R3910 1SCA022790R4040 0.02 0.03 0.06 0.09 0.16 0.24 1SCA022639R0720 0.21 Parallel connection terminal OZXA 33 Terminal clamp for Al/Cu cables. The type includes 3 pcs. OT125 2xAl/Cu 6…50 OZXT3 Interlocking device for locks S02078A Cam attachment for Castell, Lowe & Fletcher or Ronis interlock. This accessory is mounted to the operating shaft of the switch and therefore only compatible with external handles. Lock, handle or shaft not included. OT 16…125 OETLZW16 1SCA022093R2070 0.17 OZXA 38 S02077A Contact functions for OT16...125 I-Position/ Primary network Load OZXA 39 II-Position/ Secondary network S02079A 0 Main contacts I Main contacts II OZXA 40 Auxiliary contact NO S02080A Auxiliary contact NC Auxiliary contact NO OZXA 41 S01349A Auxiliary contact NC S00059A OA2G11 Auxiliary contact NO OZXT_ Auxiliary contact NC OETLZW16 S01550A Auxiliary contact NO 10 1SKC000006C0201 Auxiliary contact NC I I 0 0 II II 0 Modular change-over switches Dimension drawings OT16...32 OA1G01 EN 50022 OTS32T3 57 40 11 OH_45J5_ OTS32T1 OTPS32EP OA1G10 11 11 29,5 12 35 5,4 27 15 0 OFF 6,3 Ø66 I ON 54 35 II ON 37 40 68 60 45 36 45 37 40 12 10 22 2 2,5 5 22 13 5 ø4,5 11 13 S01306A L OH_ 45J5E311 Shaft OXP5x 150 170 265 400 13 70 (3-pole) 96 (4-pole) 13 11 L 164...175 184...195 279...290 414...425 OT45...63 OA1G01 EN 50022 73,5 11 17,5 17,5 48 45,5 OH_45J5_ OTS63T3 OTS63T1 OA1G10 OTPS63EP 17,5 15 45 16 9 17,5 14 10 0 OFF Ø66 I ON 72,5 35 91,5 II ON 37 54 82,5 45 43,5 5,0 5 43,5 2 58 45 OH_ 45J5E311 Shaft OXP5x 150 170 265 400 105 (3-pole) 10 9 43,5 11 L S01298A 36 12 5 140 (4-pole) ø4,5 11 L 183...194 203...214 298...309 433...444 OT125 11 75 EN 50022 OTS125T3 OA1G01 55 22,5 63 3,3 22,5 OTS125T1 OA1G10 OTP_125EP OH_45J5_ 12 10 45 16 16 Ø4,5 12 ø4,5 I ON Ø66 35 100 0 OFF I ON O OFF II ON 37 41 60 90 45 45 L S01299A 36 44 56,5 12 5 6,5 5 8 56 26 11 26,5 14 56 140 (3-pole) 193 (4-pole) 26 11 26,5 OH _45J5E311 Shaft OXP5x L 150 170 265 400 192...206 212...226 307...321 442...456 11 1SKC000006C0201 Open transition switches Change-over switches O I The connection of supplies to busbar systems or the connection of the busbars to earth, ensuring safe power off, is secured in the change-over switch by the inbuilt mechanical interlocking and position change via OFF-position. They prevent that parallel connection of two supplies could not occur, even in case of transient voltages. I S02054A II Transfer switch in ATSE In Automatic Transfer Switching Equipments the emergency power is automatically transferred to one or more load circuits from one supply to another by a logic system controlling the OEM transfer switch. The switches are mechanically interlocked to prevent simoultaneous connection to both normal and alternative supplies and the operator independent quick make/quick break mechanism ensures distinct opening and closing of the contacts. The range is endurance tested as transfer switch according to IEC 60947-6 categories AC-31 and AC-33, both for frequent and infrequent use, and is independent of which logic system is used for the automatic control. I-Position/ Primary network Load II-Position/ Secondary network 0 Main contacts I Main contacts II 12 II I I 0 0 II II 0 Change-over switches Technical data Data according to IEC 60947-3 Switch size Rated insulation voltage and rated operational voltage AC20/DC20 Pollution degree 3 50 Hz 1min. Dielectric strength Rated impulse withstand voltage OT160_ OT200_ OT250_ OT315_ OT400_ OT630_ OT800_ V 1000 1000 1000 1000 1000 1000 1000 kV kV 10 12 10 12 10 12 10 12 10 12 10 12 10 12 Rated thermal current and rated operational / ambient 40°C In open air A 160 200 250 315 400 630 800 current AC20/DC20 / ambient 40°C In enclosure A 160 200 250 315 400 630 800 / ambient 60°C In enclosure A Cu up to 500 V 690 V up to 500 V 690 V up to 415 V 440 V 500 V 690 V mm2 A A A A A A A A 70 160 160 160 160 160 160 160 160 95 200 200 200 200 200 200 200 200 120 250 250 250 250 250 250 250 250 185 315 315 315 315 315 315 315 315 240 400 400 400 400 400 400 400 400 2x185 630 630 630 630 630 630 630 630 2x240 800 800 800 800 800 800 800 800 230 V 400 V 415 V 500 V 690 V up to 415 V 440 V 500 V 690 V 50 kA, 415 V kW kW kW kW kW 45 90 90 110 160 1280 1280 1280 1280 40.5 55 110 110 132 160 1600 1600 1600 1600 40.5 75 132 132 160 250 2000 2000 2000 2000 40.5 90 160 160 200 315 2520 2520 2520 2520 50.5 132 200 200 250 400 3200 3200 3200 3200 50.5 200 355 355 400 630 5040 5040 5040 5040 60 250 400 400 560 800 6400 6400 6400 6400 60 gG/aM A/A 355/315 355/315 355/315 500/500 500/500 800/1000 800/1000 100 kA, 500 V gG/aM kA A 40.5 40.5 40.5 61.5 61.5 75 75 315/315 315/315 315/315 500/450 500/450 800/800 800/800 Ip (R.M.S.) Max. OFA_ fuse size 80 kA, 690 V gG/aM kA A 40.5 40.5 40.5 59 59 70 70 355/315 355/315 355/315 500/500 500/500 800/1000 800/1000 R.M.S. value Icw 690 V 0.15s 690 V 0.25s 690 V 1s 690 V kA kA kA kA 15 15 8 30 15 15 8 30 15 15 8 30 31 24 15 65 31 24 15 65 38 36 20 80 38 36 20 80 16000 16000 10000 10000 ..with minimum conductor cross section Rated operational current, AC-21A Rated operational current, AC-22A Rated operational current, AC-23A Rated operational power, AC-23A 1) The kW-ratings are accurate for 3-phase 1500 R.P.M. standard asychronous motors Rated breaking capacity in category AC-23 Rated conditional short-circuit Ip (R.M.S.) current Ip (R.M.S.) and corresponding max. allowed cut-off current îc peak value Max. OFA_ fuse size Ip (R.M.S.) Max. OFA_ fuse size The cut-off current îc refers to values listed by fuse manufacturers (single phase test acc. to IEC60269). Rated short-time withstand current A A kA Rated short-time making capacity Peak value Icm Mechanical endurance Divide by four for oper. cycles 2) Oper. 16000 16000 16000 Terminal bolt size Metric thread diameter x length mm M8x25 M8x25 M8x25 Terminal tightening torque Counter torque required Typical for 3-pole switch-disconnector Nm 15-22 15-22 15-22 30-44 30-44 50-75 50-75 Nm 7 7 7 16 16 27 27 Operating torque Weight without accessories 1) 2) M10x30 M10x30 M12x40 M12x40 3-pole switch kg 2.5 2.5 2.5 4.7 4.7 12.8 12.8 4-pole switch kg 3.2 3.2 3.2 5.8 5.8 15.6 15.6 These values are given for guidance and may vary acc. to the motor manufacturer. Operating cycle: O - I - O - II - O 13 1SKC000006C0201 Change-over switches Technical data Data according to IEC 60947-3 OETL/ Switch size OEM 200 250 315 400 630 800 1000 1250 1600 Rated insulation voltage and rated operational voltage AC20/DC20 Pollution degree 3 Dielectric strength 50 Hz 1min. Rated impulse withstand voltage Rated thermal current and rated operational current AC20/DC20 V kV kV 1000 10 12 1000 10 12 1000 10 12 1000 10 12 1000 10 12 1000 10 12 1000 8 8 1000 8 8 1000 8 8 / ambient 40°C In open air A 250 315 350 500 630 800 1000 1250 1600 / ambient 40°C In enclosure A 200 270 315 500 630 720 1000 1250 1600 175 95 220 120 260 185 500 2x 185 630 630 630 630 630 630 590 580 350 150 4) 180 315 355 355 355 63 600 2x 240 800 630 800 800 630 720 670 600 350 150 4) 200 355 355 400 355 63 900 2x (60x5) 1000 1000 1000 1000 2x (80x5) 1250 1000 1250 1250 2x (100x5) 1600 1000 1600 800 800 800 800 800 800 800 800 800 250 400 400 450 250 400 400 450 250 400 400 450 105 105 105 / ambient 60°C ..with minimum conductor cross section In enclosure A Cu mm2 Rated operational current, AC-21A Rated operational power, AC-23A The kW-ratings are accurate for 3-phase 1500 R.P.M. standard asynchronous motors. Cut-off current ic 1) I r.m.s up to 690 V 1000 V up to 500 V 690 V 1000 V up to 415 V 440 V 500 V 690 V 1000 V 220-240 V 400-415 V 440 V 500 V 690 V 50 kA, ≤ 690 V Cut-off current ic 1) I r.m.s 100 kA, 500 V Rated operational current, AC-22A Rated operational current, AC-23A A A A A A A A A A A kW kW kW kW kW kA 200 200 200 200 200 200 200 200 200 125 55 110 110 132 170 36 250 250 250 250 250 250 250 250 250 125 75 132 132 160 200 36 315 315 315 315 315 315 315 315 315 125 90 160 160 200 250 36 410 2x 150 500 400 500 500 400 500 500 500 350 125 4) 132 200 315 315 315 42 kA 48 48 48 54 70 70 400 400 400 500 630/ 800 17 50 2) 50 2) 50 2) OFAA/ OFAM-fuse size A/ A 690V, 1s kA 8 8 8 17 630/ 800 17 690V/500V kA 35 35 35 65 80 80 105 105 105 making capacity Mechanical endurance Operating cycles 3) Terminal bolt size Metric thread diameter x length Terminal tightening torque Counter torque required Operating torque 3-pole switches mm Nm Nm 8 000 8x25 30..44 13 8 000 10x30 30..44 13 8 000 10x30 30..44 13 5 000 10x40 30..44 22 5 000 12x40 50..75 22 5 000 12x40 50..75 22 3 000 12x60 50..75 25 3 000 12x60 50..75 25 3 000 12x60 50..75 25 A A A A 200 200 200 160 250 250 250 160 315 315 315 160 400 400 400 630 630 630 450 800 800 800 450 1000 800 1000 450 1250 800 1250 450 1600 800 1600 450 Rated short-time r.m.s. -value Icw Rated short circuit Peak value Icm Data according to IEC 60947-6 Rated operational current, AC-31B Rated operational current, AC-33B Rated operational current, AC-31A Rated operational current, AC-33A up to 415 V up to 415 V up to 415 V up to 415 V 1) The fuse in single phase test according to IEC 60269. 3) Operating cycle: O - I - O - II - O. 2) Maximum distance between busbar support and switch terminal 70 mm. 4) IEC947-3, utilization category B, infrequent operation. 14 1SKC000006C0201 Motor operator Technical data Technical data for motor operator OEM Rated insulation voltage (control circuit), Ui Operating temperature Rated control voltage Rated control frequency (230 VAC) Nominal voltage Us [V] Type 250V -5... +40°C 0.85...1.1 x Us 45...66 Hz Operation time [s] when operating 0-I, 0-II, I-0 or II-0 Min Max Operation time [s] when operating I-II or II-I Min Max OFF-time [s] when operating I-II or II-I Min Max Max. continuous operating rate [cycles / h] Max. short-time (≤ 10 cycles) operating rate [cycles / h] 720 24 OEM200…315 0.2 0.8 0.6 1,6 0.3 0.8 360 48 OEM200…315 0.1 0.6 0.4 1.2 0.2 0.6 360 720 230 OEM200…315 0.2 0.8 0.7 1.6 0.2 0.9 360 720 24 48 230 24 48 230 OEM400…800 OEM400…800 OEM400…800 OEM1000…1600 OEM1000…1600 OEM1000…1600 0.2 0.1 0.3 0.3 0.3 0.4 0.7 0.4 1.1 1.1 1 1.4 0.5 0.3 0.8 0.7 0.6 1 1.4 1.2 2 2 1.9 2.7 0.2 0.2 0.4 0.4 0.3 0.5 0.7 0.6 1 1 1 1.4 240 240 240 120 120 120 480 480 480 240 240 240 Nominal voltage [V] Operational current [A] Max. current [A] 230 VAC 1 4 48 VAC/VDC 5 18 24 VAC/VDC 10 36 Connection diagram for supply and control wires (max. 2,5 mm2) L1 14 13 14 13 14 13 0 F3 2 I PE 1 3 4 II 5 6 Operation functions Normal actions Continuous command Operation cycle O I II O Impulse command Operation cycle O I II O S01538A Minimum impulse duration 100 ms. Main Contacts I Main Contacts I Main Contacts II Main Contacts II Command I Command I Command O Command O Command II Command II Note! The switch position remains stable if the main voltage or the operation command disappears. See page 40 for suitable control switches for the operation circuit. Note! The switch position remains stable if the main voltage or the operation command disappears. Incorrect commands Continuous command Impulse command If two overlapping commands remain on the switch changes its position between I and II continuously. This can be prevented by mechanical or electrical interlocks in the control circuits. If the switch is in O -, I- or II -position and two commands are given at the same time, the switch changes its position in occasional order. 15 1SKC000006C0201 Change-over switches Ordering information Manual change-over switches, 3-pole, I-0-II -operation, open transition Including a black plastic IP65 I - 0 - II pistol type handle, padlockable in the 0-position, door interlock in the I- and II-positions and when padlocked. Table below. Rated current / Rated power AC-21A...AC-22A Up to 415V 400V I[A] S[kVA] OT160...250E03CP Type Order number Weight AC-23A 400...415V I[A] / P[kW] [kg] Mechanism at the end of the switch 160 110 160/90 OT160E03CP 1SCA022772R6510 200 135 200/110 OT200E03CP 1SCA022771R7520 250 170 250/132 OT250E03CP 1SCA022771R3450 315 215 315/160 OT315E03CP 1SCA022772R6780 400 275 400/200 OT400E03CP 1SCA022771R8500 630 435 630/355 OT630E03CP 1SCA022785R6050 800 550 800/400 OT800E03CP 1SCA022785R6300 Mechanism between the poles 160 110 160/90 OT160E12CP 1SCA022776R9080 200 135 200/110 OT200E12CP 1SCA022776R8510 250 170 250/132 OT250E12CP 1SCA022776R9320 315 215 315/160 OT315E12CP 1SCA022776R9910 400 275 400/200 OT400E12CP 1SCA022776R9590 630 435 630/355 OT630E12CP 1SCA022785R8690 800 550 800/400 OT800E12CP 1SCA022785R8850 Mechanism at the end of the switch, with extended phase distance 160 110 160/90 OT160E03WCP 1SCA022772R8210 200 135 200/110 OT200E03WCP 1SCA022772R8720 250 170 250/132 OT250E03WCP 1SCA022772R8300 Mechanism at the right end of the switch 1000 690 800/400 OETL1000K3C 1SCA022574R7100 1250 860 800/400 OETL1250K3C 1SCA022574R7360 1600 1100 800/400 OETL1600K3C 1SCA022574R7520 OT315...400E03CP OT630...800E03CP 3.3 3.3 3.3 5.9 5.9 17.7 17.7 3.3 3.3 3.3 5.9 5.9 17.7 17.7 3.6 3.6 3.6 38 38 40 OT160...250E03WCP S01294A I ON FF OO OETL1000...1600K3C 16 1SKC000006C0201 Shafts, handle and bolt kits included as standard Suitable for switches Shaft Handle Bolt kit OT160...250 OT315...400 OT630...800 OETL1000...1600 OXP6x161 OXP12x166 OXP12x185 OXP12x325 OHB65J6E011 OHB95J12E011 OHB125J12E011 OHB175J12E011 M8x25 M10x30 M12x40 M12x60 Change-over switches Ordering information Manual change-over switches, 4-pole, I-0-II -operation, open transition Including a black plastic IP65 I - 0 - II pistol type handle, padlockable in the 0-position, door interlock in the I- and II-positions and when padlocked. Table below. Rated current / Rated power AC-21A...AC-22A Up to 415V 400V I[A] S[kVA] OT160...250E04CP Type Order number Weight AC-23A 400...415V I[A] / P[kW] [kg] Mechanism at the end of the switch 160 110 160/90 OT160E04CP 1SCA022775R9440 200 135 200/110 OT200E04CP 1SCA022771R7280 250 170 250/132 OT250E04CP 1SCA022775R4640 315 215 315/160 OT315E04CP 1SCA022775R7150 400 275 400/200 OT400E04CP 1SCA022771R8680 630 435 630/355 OT630E04CP 1SCA022785R6130 800 550 800/400 OT800E04CP 1SCA022785R6210 Mechanism between the poles 160 110 160/90 OT160E13CP 1SCA022777R0170 200 135 200/110 OT200E13CP 1SCA022777R0250 250 170 250/132 OT250E13CP 1SCA022777R0330 315 215 315/160 OT315E13CP 1SCA022777R0410 400 275 400/200 OT400E13CP 1SCA022777R0500 630 435 630/355 OT630E13CP 1SCA022785R9070 800 550 800/400 OT800E13CP 1SCA022785R9230 Mechanism at the end of the switch, with extended phase distance 160 110 160/90 OT160E04WCP 1SCA022775R0220 200 135 200/110 OT200E04WCP 1SCA022775R0650 250 170 250/132 OT250E04WCP 1SCA022775R0810 OT315...400E13CP Mechanism at the right end of the switch 1000 690 800/400 1250 860 800/400 1600 1100 800/400 OT630...800E04CP OETL1000K4C OETL1250K4C OETL1600K4C 4.1 4.1 4.1 7.1 7.1 21 21 4.1 4.1 4.1 7.1 7.1 21 21 4.4 4.4 4.4 1SCA022574R7280 1SCA022574R7440 1SCA022574R7610 50 50 52 OT160...250E04WCP OETL1000...1600K4C Shafts, handle and bolt kits included as standard I ON S01411A FF OO Suitable for switches Shaft Handle Bolt kit OT160...250 OT315...400 OT630...800 OETL1000...1600 OXP6x161 OXP12x166 OXP12x185 OXP12x325 OHB65J6E011 OHB95J12E011 OHB125J12E011 OHB175J12E011 M8x25 M10x30 M12x40 M12x60 17 1SKC000006C0201 Change-over switches Ordering information Change-over switches, motor operation, 3-pole, I-0-II -operation, open transition Including a metallic I - 0 - II pistol handle, for manual operation. S01316A l O l Rated current / Rated power AC-21A...AC-22A AC-23A Up to 415V 400V 400...415V I[A] S[kVA] I[A] / P[kW] O O II I Type Order number Weight [kg] Motor operation, operational voltage Un = 24V AC/DC S01315A OEM200-315K3C O I II 200 250 315 500 630 800 1000 1250 1600 135 170 215 345 435 550 690 860 1100 200/110 250/ 132 315/160 500/200 630/315 720/355 800/400 800/400 800/400 OEM200K3C24AC/DC OEM250K3C24AC/DC OEM315K3C24AC/DC OEM400K3C24AC/DC OEM630K3C24AC/DC OEM800K3C24AC/DC OEM1000K3C24AC/DC OEM1250K3C24AC/DC OEM1600K3C24AC/DC 1SCA022607R4990 1SCA022607R5020 1SCA022607R5110 1SCA022607R5290 1SCA022607R5370 1SCA022607R5450 1SCA022607R5530 1SCA022607R5610 1SCA022607R5700 19 19 19 29 29 29 46 46 48 1SCA022607R6690 1SCA022607R6510 1SCA022607R6420 1SCA022607R6340 1SCA022607R6260 1SCA022607R6180 1SCA022607R6000 1SCA022607R5960 1SCA022607R5880 19 19 19 29 29 32 46 46 48 1SCA022608R6770 1SCA022608R6850 1SCA022608R6930 1SCA022608R7070 1SCA022607R7150 1SCA022607R7230 1SCA022607R7310 1SCA022607R7400 1SCA022607R7580 19 19 19 29 29 29 46 46 49 Motor operation, operational voltage Un = 48V AC/DC 200 250 315 500 630 800 1000 1250 1600 OEM400-800K3C S01305A O I OEM1000...1600K3C II 135 170 215 345 435 550 690 860 1100 200/110 250/ 132 315/160 500/200 630/315 720/355 800/400 800/400 800/400 OEM200K3C48AC/DC OEM250K3C48AC/DC OEM315K3C48AC/DC OEM400K3C48AC/DC OEM630K3C48AC/DC OEM800K3C48AC/DC OEM1000K3C48AC/DC OEM1250K3C48AC/DC OEM1600K3C48AC/DC Motor operation, operational voltage Un = 230V AC 200 250 315 500 630 800 1000 1250 1600 135 170 215 345 435 550 690 860 1100 200/110 250/132 315/160 500/200 630/315 720/355 800/400 800/400 800/400 OEM200K3C230AC OEM250K3C230AC OEM315K3C230AC OEM400K3C230AC OEM630K3C230AC OEM800K3C230AC OEM1000K3C230AC OEM1250K3C230AC OEM1600K3C230AC Handle and bolt kits included as standard YASDA_ 18 1SKC000006C0201 Suitable for switches Handle Bolt kit OEM200 OEM250...315 OEM400...800 OEM1000...1600 YASDA23/ 1 YASDA23/ 1 YASDA23/ 2 YASDA23/ 3 M8x25 M10x30 M12x40 M12x60 Change-over switches Ordering information Change-over switches, motor operation, 4-pole, I-0-II -operation, open transition S01516A Including a metallic I - 0 - II pistol handle, for manual operation. Rated current / Rated power AC-21A...AC-22A AC-23A Up to 415V 400V 400...415V I[A] S[kVA] I[A] / P[kW] O II I Type Order number Weight [kg] Motor operation, operational voltage Un = 24V AC/DC S01517A OEM200-315K4C l O O l O II I 200 250 315 500 630 800 1000 1250 1600 135 175 217 345 435 550 690 860 1100 200/110 250/ 132 315/160 500/200 630/315 720/355 800/400 800/400 800/400 OEM200K4C24AC/DC OEM250K4C24AC/DC OEM315K4C24AC/DC OEM400K4C24AC/DC OEM630K4C24AC/DC OEM800K4C24AC/DC OEM1000K4C24AC/DC OEM1250K4C24AC/DC OEM1600K4C24AC/DC 1SCA022607R8550 1SCA022607R8470 1SCA022607R8390 1SCA022607R8210 1SCA022607R8120 1SCA022607R8040 1SCA022607R7910 1SCA022607R7820 1SCA022607R7660 20 20 20 30 30 32 58 58 60 1SCA022607R8630 1SCA022607R8710 1SCA022607R8800 1SCA022607R8980 1SCA022607R9010 1SCA022607R9100 1SCA022607R9280 1SCA022607R9360 1SCA022607R9440 20 20 20 30 30 32 58 58 60 1SCA022608R0370 1SCA022608R0290 1SCA022608R0110 1SCA022608R0020 1SCA022607R9950 1SCA022607R9870 1SCA022607R9790 1SCA022607R9610 1SCA022607R9520 20 20 20 30 30 32 58 58 60 Motor operation, operational voltage Un = 48V AC/DC 200 250 315 500 630 800 1000 1250 1600 OEM400-800K4C O S01412A I OEM1000...1600K4C 135 175 217 345 435 550 690 860 1100 200/110 250/ 132 315/160 500/200 630/315 720/355 800/400 800/400 800/400 OEM200K4C48AC/DC OEM250K4C48AC/DC OEM315K4C48AC/DC OEM400K4C48AC/DC OEM630K4C48AC/DC OEM800K4C48AC/DC OEM1000K4C48AC/DC OEM1250K4C48AC/DC OEM1600K4C48AC/DC II Motor operation, operational voltage Un = 230V AC 200 250 315 500 630 800 1000 1250 1600 135 170 215 345 435 550 690 860 1100 200/110 250/132 315/160 500/200 630/315 720/355 800/400 800/400 800/400 OEM200K4C230AC OEM250K4C230AC OEM315K4C230AC OEM400K4C230AC OEM630K4C230AC OEM800K4C230AC OEM1000K4C230AC OEM1250K4C230AC OEM1600K4C230AC Handle and bolt kits included as standard YASDA_ Suitable for switches Handle Bolt kit OEM200 OEM250...315 OEM400...800 OEM1000...1600 YASDA23/ 1 YASDA23/ 1 YASDA23/ 2 YASDA23/ 3 M8x25 M10x30 M12x40 M12x60 19 1SKC000006C0201 Accessories Ordering information Handles, door mounting Plastic I - 0 - II handle, IP65, door interlock in I- and II-position and when padlocked. OHB_ Suitable for switches Colour Shaft diam. [mm] Type Order number Weight [kg] black 6 OHB65J6E011 red/yellow 6 OHY65J6E011 OT315…400E_C black 12 OHB95J12E011 red/yellow 12 OHY95J12E011 OT630…800E_C black 12 OHB125J12E011 red/yellow 12 OHY125J12E011 OETL1000...1600 black 12 OHB175J12E011 red/yellow 12 OHY175J12E011 Padlockable with three padlocks in I- , 0- and II-position 1SCA022383R2480 1SCA022779R1840 1SCA022621R0760 1SCA022621R0920 1SCA022589R3340 1SCA022615R1650 1SCA022459R9700 1SCA022461R1920 0.12 0.12 0.12 0.12 0.14 0.14 0.17 0.17 OT160…250E_C OT315…400E_C OT630…800E_C black black black 6 12 12 OHB65J6E311 OHB95J12E311 OHB125J12E311 1SCA022662R4730 1SCA022779R2140 1SCA022615R1730 0.12 0.12 0.14 OETL1000…1600 black 12 OHB175J12E311 1SCA022615R1810 0.17 Padlockable with three padlocks in 0-position I S00865A O OFF NO OHY_ O OFF S00469A NO I OHB_ OT160…250E_C Handles, direct mounting S01997A Plastic I - 0 - II handle, padlockable with three padlocks in 0-position. Includes a shaft and a mechanism cover. OTV_ OT160…250E_C OT315…400E_C OT630…800E_C black black black shaft incl. shaft incl. shaft incl. OTV250ECK OTV400ECK OTV800ECK 1SCA022783R0090 1SCA022783R0170 1SCA022797R2470 0.08 0.26 0.30 Type Order number Weight [kg] OXP6X90 OXP6X130 OXP6X161 OXP6X210 OXP6X290 OXP6X360 1SCA022064R1180 1SCA022057R0570 1SCA022067R1760 1SCA022295R6080 1SCA022042R6370 1SCA022042R6530 0.03 0.04 0.05 0.06 0.08 0.11 OXP12X107 OXP12X148 OXP12X166 OXP12X185 OXP12X250 OXP12X280 OXP12X325 OXP12X395 OXP12X465 OXP12X148 OXP12X185 OXP12X250 OXP12X325 OXP12X395 OXP12X465 OXP12X185 OXP12X250 OXP12X325 OXP12X395 OXP12X465 1SCA022029R9750 1SCA022658R5570 1SCA022325R7100 1SCA022325R6710 1SCA022325R6980 1SCA022137R5140 1SCA022042R5810 1SCA022042R5990 1SCA022042R6020 1SCA022658R5570 1SCA022325R6710 1SCA022137R5140 1SCA022042R5810 1SCA022042R5990 1SCA022042R6020 1SCA022325R6710 1SCA022325R6980 1SCA022042R5810 1SCA022042R5990 1SCA022042R6020 0.12 0.17 0.20 0.22 0.29 0.33 0.38 0.46 0.54 0.17 0.22 0.29 0.38 0.46 0.54 0.22 0.29 0.38 0.46 0.54 Extended shafts S00050A Suitable for switches OXP6_ OXP12_ 20 1SKC000006C0201 Installation depth [mm] Shaft diameter 6 mm OT160...250E_C 166…214 209…254 240…285 289…334 369…414 439…484 Shaft diameter 12 mm OT315...400E_C 209…266 243…307 261…325 280…344 345…409 375…439 420…484 490…554 560…624 OT630…800E_C 287...355 324...422 389...487 464...562 534...632 604...702 OETL1000…1600 364...437 429...502 504...577 574...647 644...717 Accessories Ordering information Auxiliary contact blocks S00261A Mounting on the right side of the switch: Max. 4 auxiliary contact blocks/switch (totally 8 blocks). Simultaneous action with the main contacts, IP20. Suitable for switches OA_G_ Contact function Type Order number OT160...800 1NO OA1G10 1SCA022353R4970 1NC OA3G01 1SCA022456R7410 Mounting locations, see dimensional drawings. Contact functions, see the page 23. 1SCA022144R7400 OEM200…315 1NO+1NC OZXK12 1) 2NO+2NC OZXK13 1) 1SCA022144R7230 2NO+2NC OZXK29 2) 1SCA022615R1570 OETL/OEM400...1600 1NO+1NC OZXK1 1) 2) 1SCA022131R8690 1) 2) 2NO+2NC OZXK2 1SCA022131R8850 I ON S00536A O OFF 21 13 41 33 Weight [kg] 0.03 0.03 0.08 0.12 0.08 0.12 0.12 OZXK_ Terminal shrouds Suitable for switches OTS_S S01414A OTS_L S00216A S00215A OETLZXC 11...22 S00218A S00217A OZXB2K A S00219A 20 02 S0 OZXB4K Type Order number Weight [kg] Snap-on mounting, grey plastic Transparent shrouds for OT160...800 available on request, please replace the letter "G" with "T". Suitable for the upper switch. A kit includes three (four) shrouds which can be used on either side of the switch. OT160…250 3 Long type OTS250G1L/3 1SCA022731R8150 0.09 3 Short type OTS250G1S/3 1SCA022731R8310 0.06 OT160…250 4 Long type OTS250G1L/4 1SCA022731R8230 0.12 4 Short type OTS250G1S/4 1SCA022731R8400 0.08 OT315…400 3 Long type OTS400G1L/3 1SCA022736R8840 0.15 3 Short type OTS400G1S/3 1SCA022736R9060 0.09 OT315…400 4 Long type OTS400G1L/4 1SCA022736R9490 0.20 4 Short type OTS400G1S/4 1SCA022736R9650 0.12 OT630…800 3 Long type OTS800G1L/3 1SCA022776R7890 0.32 3 Short type OTS800G1S/3 1SCA022776R8190 0.17 OT630…800 4 Long type OTS800G1L/4 1SCA022776R7970 0.42 4 Short type OTS800G1S/4 1SCA022776R8270 0.26 Snap-on mounting, transparent plastic OEM200..315 3 OETLZXC11 1SCA022608R1510 0.20 4 OETLZXC12 1SCA022608R1690 0.25 OEM400 3 OETLZXC13 1SCA022608R1770 0.30 4 OETLZXC14 1SCA022608R1850 0.35 OEM630 3 OETLZXC15 1SCA022608R7710 0.30 4 OETLZXC16 1SCA022608R7890 0.35 OEM800 3 OETLZXC17 1SCA022658R9300 0.35 4 OETLZXC18 1SCA022658R9480 0.40 OETL/OEM1000-1250 3 OETLZXC19 1SCA022658R9560 0.45 4 OETLZXC20 1SCA022658R9640 0.55 OETL/OEM1600 3 OETLZXC21 1SCA022658R9720 0.45 4 OETLZXC22 1SCA022658R9810 0.55 Snap-on mounting to the terminal clamps, transparent plastic, IP 2X. Suitable for terminal clamps Number of poles Type Order number Weigh [kg] OZXB2, 2L OZXB3, 4 OZXB5, 6 OZXB7, 7L 3 3 3 3 OZXB2K OZXB3K OZXB4K OZXB5K 1SCA022264R0010 1SCA022264R0440 1SCA022199R2850 1SCA022283R8040 0.05 0.20 0.24 0.13 S00224A S00222A S00221A S00223A OZXB3K Number Description of poles OZXB5K 1) Suitable for the upper switch 2) Suitable for the lower switch 21 1SKC000006C0201 Accessories Ordering information Terminal clamp sets S00177A Suitable for switches S00179A OZXB 1L S01806A OZXB 2 S00182A OZXB 8, 9 S00186A OZXB 2L, 7L OZXB 3 S00188A S00082A OZXA 11 Suitable shroud Terminal clamp sets for Al- and Cu-cables OT 160...250 10...70 OTS250_L 10...70 OTS250_L 25...120 OZXB2K 25...120 OZXB2K 25...120 OZXB2K 25...120 OZXB2K 95...185 OTS250_L 95...185 OTS250_L 95...240 OTS250_L 95...240 OTS250_L OT 315...400 25...120 OZXB2K 25...120 OZXB2K 95…185 OZXB3K 95…185 OZXB3K 2x(95…185) OZXB3K 2x(95…185) OZXB3K 120...240 OZXB5K 120...240 OZXB5K 120...240 OZXB5K 120...240 OZXB5K 95...185 OTS400_L 95...185 OTS400_L 95...240 OTS400_L 95...240 OTS400_L OT630…800 120…300 OZXB4K 120…300 OZXB4K 2x(120…300) OZXB4K 2x(120…300) OZXB4K Terminal clamp sets for Cu-cables Suitable for switches OZXB 4 Cable cross section [mm2] Cable cross section [mm2] OEM400 70…120 OEM400 2x(70...95) OEM400 120…185 OEM630…800 2x(95…185) OEM630…800 185...240 Terminal clamp sets for Al- and Cu-cables OEM400 25...120 Al/Cu OETL/OEM400...1600 70…185 Al/Cu S00083A 2x(70…185) Al/Cu OZXA 12...14 OETL/OEM400…1600 120…300 Al/Cu OETL/OEM400...1600 2x(120…300) Al/Cu OEM400...800 120...240 Al/Cu Type Order number Package Weight [pcs] [kg] 0.15 0.05 0.34 0.12 0.43 0.15 0.50 0.15 0.50 0.15 0.43 0.15 1.28 0.43 1.71 0.57 1.00 0.34 1.17 0.40 0.50 0.15 0.50 0.15 2.28 0.76 3.12 1.04 OZXB1L OZXB1L/1 OZXB2 OZXB2/1 OZXB2L OZXB2L/1 OZXB8 OZXB8/1 OZXB9 OZXB9/1 OZXB2L OZXB2L/1 OZXB3 OZXB3/1 OZXB4 OZXB4/1 OZXB7 OZXB7/1 OZXB7L OZXB7L/1 OZXB8 OZXB8/1 OXZB9 OZXB9/1 OZXB5 OZXB5/1 OZXB6 OZXB6/1 1SCA022169R2030 1SCA022194R0030 1SCA022119R7610 1SCA022194R0200 1SCA022158R7750 1SCA022194R0460 1SCA022744R1510 1SCA022744R1600 1SCA022750R3210 1SCA022750R3300 1SCA022158R7750 1SCA022194R0460 1SCA022136R8100 1SCA022194R0620 1SCA022137R4760 1SCA022194R0890 1SCA022185R0040 1SCA022194R1430 1SCA022185R7130 1SCA022194R1600 1SCA022744R1510 1SCA022744R1600 1SCA022750R3210 1SCA022750R3300 1SCA022137R2470 1SCA022194R1010 1SCA022137R4920 1SCA022194R1270 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 Type Order number Package Weight [pcs] [kg] OZXA11 OZXA12 OZXA12 OZXA14 OZXA14 1SCA022025R6940 1SCA022008R7650 1SCA022008R7650 1SCA022008R7810 1SCA022008R7810 6 6 6 6 6 0.54 0.66 0.66 1.18 1.18 OZXB2L OZXB2L/1 OZXB3 OZXB3/1 OZXB4 OZXB4/1 OZXB5 OZXB5/1 OZXB6 1) OZXB6/11) OZXB7L OZXB7L/1 1SCA022158R7750 1SCA022194R0460 1SCA022136R8100 1SCA022194R0620 1SCA022137R4760 1SCA022194R0890 1SCA022137R2470 1SCA022194R1010 1SCA022137R4920 1SCA022194R1270 1SCA022185R7130 1SCA022194R1600 3 1 3 1 3 1 3 1 3 1 3 1 0.43 0.14 1.28 0.43 1.71 0.57 2.28 0.76 3.12 1.04 1.17 0.40 Terminal clamp sets for connection bar OETLZXC 23 OEM400…630 OEM630…800 70…185 Al/Cu OZXB3 OZXB3/1 1SCA022136R8100 1SCA022194R0620 3 1 1.28 0.43 2x(70…185) Al/Cu OZXB4 OZX4/1 OZXB5 OZXB5/1 OZXB6 OZXB6/1 1SCA022137R4760 1SCA022194R0890 1SCA022137R2470 1SCA022194R1010 1SCA022137R4920 1SCA022194R1270 3 1 3 1 3 1 1.71 0.57 2.28 0.76 3.12 1.04 120…300 Al/Cu 2x(120…300) Al/Cu 1) 22 1SKC000006C0201 For OEM400...800 use connection bar OETLZXC 23. Accessories Ordering information Bridging bars The bridging bars provide a connection link either on the incoming or outcoming side of the switch. OTZC_ Suitable for switches Number of poles Type Order number Weight [kg] OT160…250 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 OTZC13 OTZC14 OTZC23 OTZC24 OTZC33 OTZC34 OETLZXC1 OETLZXC2 OETLZXC3 OETLZXC4 OETLZXC5 OETLZXC6 OETLZXC7 OETLZXC8 OETLZXC9 OETLZXC10 1SCA022767R6910 1SCA022767R7040 1SCA022767R7120 1SCA022767R7210 1SCA022785R7020 1SCA022785R7110 1SCA022608R0450 1SCA022608R0530 1SCA022608R0610 1SCA022608R0700 1SCA022608R0880 1SCA022608R0960 1SCA022608R1000 1SCA022608R1180 1SCA022608R1260 1SCA022608R1340 0.60 0.80 0.60 0.80 1.00 1.30 0.60 0.80 0.60 0.80 1.30 1.80 5.40 7.20 7.50 10.0 OT315…400 OT630…800 OEM200…315 OETLZXC1...10 OEM400 OEM630…800 S01413A OETL/OEM1000…1250 OETL/OEM1600 Connection bar For connecting Al/Cu cables using terminal clamps OZXB6. Mounting to bridging bars OETLZXC_. Bolt kit included. OEM400...800 1 OETLZXC23 1SCA022659R7580 0.20 S00059A OETLZXC23 OETLZW_ Locking accessories Cam attachment for adopting the switches to Castell, Lowe&Fletcher or Ronis interlock. The lock is not included. Mounting to OXP-shaft, works together with OH-door handle and a shaft. OETLZWC 1 Suitable for switches Type Order number Weight [kg] OT160…250 OT315…400 OETLZW16 OETLZW5 1SCA022093R2070 1SCA022052R3900 0.17 0.14 OETLZWC1 1SCA022608R1420 1.10 Direct mounting to the switch with OH_ handle OETL200...1600K_C Contact functions for OETL/OEM200...1600 I-Position/ Primary network Load II-Position/ Secondary network 0 I I 0 0 II II 0 Main contacts I Main contacts II Auxiliary contact NO Auxiliary contact NC Auxiliary contact NO S01499A S01518A I ON FF OO Auxiliary contact NC Note! The NO auxiliary contact, on switch I, in OEM200...315 closes at the same time as the main contacts. 23 1SKC000006C0201 Change-over switches Dimension drawings OT160E03/04CP... OT250E03/04CP A A1 A2 B 35 116 155 170 35 116 190 205 OT160E12/13CP... OT250E12/13CP OT160... 250_CK 37 150 9,0 20 38,5 83 3 72 25 122 100 14 130 A 130 150 A1 58,3 65 60 A B 24 1SKC000006C0201 25 187 A A1 A2 B OT 160...250E_C E03 E04 35 35 116 116 156 191 171 206 M00094 / OT160...250_CK A2 32,5 25 Change-over switches Dimension drawings OT160E03/04WCP... OT250E03/04WCP OT315E03/04CP and OT400E03/04CP OT315E12/13CP... OT400E12/13CP 25 1SKC000006C0201 Change-over switches Dimension drawings OT315E03/04CK... 400E03/04CK OT630E03/04CP... 800E03/04CP OT630E12/13CP... 800E12/13CP 26 1SKC000006C0201 Change-over switches Dimension drawings OT630E03/04CK... 800E03/04CK OETL1000...1600 OETL 1000K3C OETL 1250K3C OETL 1600K3C OETL 1000K4C OETL 1250K4C OETL 1600K4C I I 297 9x17 14 24 15 12 9x17 Ø9 14 195 24 15 Ø9 Ø66 95 95 190 254 373 I O 190 254 373 333 I O 333 212 175 39,5 20 39,5 20 D 215 61 315 L 40 59 59 50 C 17 B 52,5 OETL 1000K3C OETL 1000K4C OETL 1250K3C OETL 1250K4C OETL 1600K3C OETL 1600K4C 17 OZXK 1 or 2 ( Upper and Lower Switch ) Shaft OXP 12x B 278 358 278 358 298 388 B A OETL 1000K3C...OETL1600K4C A 390 470 390 470 410 500 50 C 52,5 A OZXK 1 or 2 ( Upper and Lower Switch ) S01291A 36 C 80 80 80 80 90 90 D 12 12 12 12 16 16 I 247 327 247 327 267 357 185 250 325 395 465 Mounting depth/L 364...437 429...502 504...577 574...647 644...717 27 1SKC000006C0201 Change-over switches Dimension drawings OEM200...315 237 I C 155 Ø7 9x7 F 22 0 l O 162 110 137 102 126 130 I II 288 276 4 32 4 ØB OZXK 12 or 13 (upper switch) 28 OZXK 29 (lower switch) 145,5 159 S01319A 85 32 D 180 260 118 A OEM 200K3C...OEM 315K4C ØB F A C OEM 200K3C 9 20 289 157 OEM 200K4C 9 20 335 203 OEM 250K3C 11 25 289 157 OEM 250K4C 11 25 335 203 OEM 315K3C 11 25 289 157 OEM 315K4C 11 25 335 203 D 46 46 46 46 46 46 I 149 195 149 195 149 195 OEM400...800 295 I F 8 165 55 ØG B 17 13x7 0 l 163 172 C E 150 120 II I O 307 288 276 85 H 45 134 H Ø7 216 145,5 A 315 S01416D OEM 400K3C...OEM 800K4C 28 1SKC000006C0201 OEM OEM OEM OEM OEM OEM 400K3C 400K4C 630K3C 630K4C 800K3C 800K4C D OZXK 1 or 2 (upper and lower switch) 28 159 32 A B C D E F G H I 291 337 323 385 339 409 162 208 194 257 210 280 205 205 223 223 223 223 46 46 62 62 70 70 180 180 185 185 185 185 25 25 40 40 40 40 11 11 13,5 13,5 13,5 13,5 4 4 5 5 5 5 146 192 178 240 194 264 118 Change-over switches Dimension drawings OEM1000...1600 I 195 227 212 276 B 14 Ø9 15 254 95 333 190 9x17 24 0 I I O II 419 288 85 39,5 145,5 20 59 C 50 52,5 118 A 317 159 S01320A D 40 215 D 28 OEM 1000K3C...OEM 1600K4C A B 414 278 OEM 1000K3C OEM 1000K4C 494 358 414 278 OEM 1250K3C OEM 1250K4C 494 358 OEM 1600K3C 434 298 OEM 1600K4C 524 388 OZXK 1 or 2 ( upper and lower switch ) C 80 80 80 80 90 90 D 12 12 12 12 16 16 I 237 317 237 317 257 347 Plastic handles 36 Ø66 45 Handle type II ON S00473A O OFF B OH_65J6E_ OH_80J6E_ OH_95J12E_ OH_125J12E_ OH_145J12E_ OH_175J12E_ OH_275J12E_ L Handle length (mm) L Shaft (mm) B 65 80 95 125 145 175 275 6 6 12 12 12 12 12 Door drilling for OH_ handles: ø5 ø5 S02111A ø31 S02064A II ON 45° 0 OFF 45° 0 OFF I ON I ON 53 ø31 II ON 53 29 1SKC000006C0201 Open transition switches Transfer switches, UL approved The global solution This range is covering manual change-over functions from primary supply to back-up supply in equipment specially designed for the UL market, but also used on the IEC market. The OETL-NFC range is UL 1008 Recognized for resistive load up to 1200 A and for total load up to 630 A. The corresponding IEC rating is up to 1600 A for the OETL-NFC range. Load Main contacts I Main contacts II 30 I-Position/ Primary network II-Position/ Secondary network Transfer switches Technical data Data according to UL1008 (Recognized) Switch size OETL-NFC 200 400 600 800 1200 V A 600 200 600 400 600 600 600 800 600 1200 V A 240 200 240 400 240 500 240 630 V kV kV 1000 10 12 1000 10 12 1000 10 12 1000 8 8 1000 8 8 A A A mm2 315 270 220 120 up to 690 V 1000 V up to 500 V 690 V 1000 V up to 415 V 440 V 500 V 690 V 1000 V 50 kA ≤ 690 V 100 kA, 500 V A A A A A A A A A A kA kA 250 250 250 250 250 250 250 250 250 125 36 48 630 630 500 2x 185 630 630 630 630 630 630 590 580 350 150 4) 63 70 800 720 600 2x 240 800 630 800 800 630 720 670 600 350 150 4) 63 70 1250 1250 1000 2x (80x5) 1250 1000 1250 1600 1600 1250 2x (100x5) 1600 1000 1600 800 800 800 800 800 800 105 105 690V, 1s kA 8 17 17 50 2) 50 2) 35 6 000 10x30 30..44 13 80 4 000 12x40 50..75 22 80 3 000 12x40 50..75 22 105 3 000 12x60 50..75 25 105 3 000 12x60 50..75 25 250 250 250 160 630 630 630 450 800 800 800 450 1250 800 1250 450 1600 800 1600 450 Resistive load Voltage Current Total load Voltage Current Data according to IEC 60947-3 Rated insulation voltage and rated operational voltage AC20/DC20 Pollution degree 3 Dielectric strength 50 Hz 1min. Rated impulse withstand voltage Rated thermal current and rated operational current AC20/DC20 / ambient 40°C In open air / ambient 40°C In enclosure / ambient 60°C In enclosure ..with minimum conductor cross section Cu Rated operational current, AC-21A Rated operational current, AC-22A Rated operational current, AC-23A Cut-off current ic 1) I r.m.s Cut-off current ic 1) I r.m.s Rated short-time withstand current r.m.s. -value Icw Rated short circuit making capacity Peak value Icm Mechanical endurance, manual Terminal bolt size Metric thread diameter x length Terminal tightening torque Counter torque required Operating torque 3-pole switches 690V kA Operating cycles 3) mm Nm Nm Data according to IEC 60947-6 Rated operational current 1) 2) AC-31B AC-33B AC-31A AC-33A up to 415 V up to 415 V up to 415 V up to 415 V The fuse in single-phase test according to IEC 60269. Maximum distance between busbar support and switch terminal 70 mm. A A A A 3) 4) Operating cycle: O - I - O - II - O. IEC947-3, utilization category B, infrequent operation. 31 1SKC000006C0201 Transfer switches Ordering information Change-over switches, 3-pole, I-O-II -operation, open transition The change-over switches include a black handle IP65; see the table below, Nema type 1, 3R, 12, a shaft and a bolt set for the cable connection and a set of phase barriers (200...600). I ON S01293A FF OO S01292A OETL-NFC200 l O I ON FF OO l Rated current [A] UL1008 IEC60947-3 IEC60947-6 600 V ≤ 415 V ≤ 415 V Resistive AC-22A AC-31A Type Order number Weight [kg] 200 400 600 800 1200 OETL-NFC200-P OETL-NFC400-P OETL-NFC600-P OETL-NFC800-P OETL-NFC1200-P 1SCA022596R0980 1SCA022596R1010 1SCA022596R1100 1SCA022596R1280 1SCA022596R1360 10 19 19 38 40 250 630 800 1250 1600 250 630 800 1250 1600 O Change-over switches, 4-pole, I-O-II -operation, open transition OETL-NFC400-600 The change-over switches include a black handle IP65, Nema type 1, 3R, 12, shaft and bolt set for the cable connection and a set of phase barriers (200...600). S01294A I ON FF OO Rated current [A] UL1008 IEC60947-3 IEC60947-6 600 V ≤ 415 V ≤ 415 V Resistive AC-22A AC-31A Type Order number Weight [kg] 200 400 600 800 1200 OETL-NFC200-4P OETL-NFC400-4P OETL-NFC600-4P OETL-NFC800-4P OETL-NFC1200-4P 1SCA022702R4080 1SCA022702R4160 1SCA022705R1990 1SCA022705R2020 1SCA022705R2110 12 23 23 50 52 250 630 800 1250 1600 250 630 800 1250 1600 OETL-NFC800-1200 Shafts, handles and bolt kits included as standard O OFF S00469A NO I OHB_ 32 1SKC000006C0201 The handles are equipped with door interlock function in both I- and II-position and when padlocked. Padlocking possibility in O-position with 3 padlocks, bail dia Ø 5...10 mm. Indication I-O-II. Suitable for switches Shaft Handle Bolt kit OETL-NFC 200_ OETL-NFC 400...600_ OETL-NFC 800...1200_ OXP12x325 OXP12x325 OXP12x325 OHB125J12E011 OHB145J12E011 OHB175J12E011 M10x30 M12x40 M10x50 Accessories Ordering information External handles, IP 65, Nema type 1, 3R, 12, indication I - O- II NO I S00865A O OFF The handles are equipped with door interlock function in both I- and II-position and when padlocked. Padlocking with 3 padlocks, bail dia Ø5...10 mm. For switches OETL-NFC 200 black OETL-NFC 400...600 black OETL-NFC 800...1200 black OETL-NFC200 red/yellow OETL-NFC400…600 red/yellow OETL-NFC800…1200 red/yellow Padlocking possibility in all positions OETL-NFC200 black OETL-NFC400…600 black OETL-NFC800…1200 black NO I O OFF S00469A Colour Type Order number Weight [kg] OHB125J12E011 OHB145J12E011 OHB175J12E011 OHY125J12E011 OHY145J12E011 OHY175J12E011 1SCA022589R3340 1SCA022399R8530 1SCA022459R9700 1SCA022615R1650 1SCA022460R7060 1SCA022461R1920 0.14 0.15 0.17 0.14 0.15 0.17 OHB125J12E311 OHB145J12E311 OHB175J12E311 1SCA022615R1730 1SCA022500R1390 1SCA022615R1810 0.14 0.15 0.17 Padlocking possibility in O-position OHY_ S00047A OHB_ Extended shafts OXP 12X_ For switches Length [mm] Type Order number Weight [kg] OETL-NFC200…1200 OETL-NFC200…1200 395 465 OXP12x395 OXP12x465 1SCA022042R5990 1SCA022042R6020 0.45 0.53 Auxiliary contacts I ON Mounting locations, see dimension drawings. Contact functions, see the next page. S00536A O OFF 21 13 41 OZXK_ 33 For switches Contact functions Type Order number Weight [kg] OETL-NFC200 OETL-NFC200 OETL-NFC200 OETL-NFC400...1200 OETL-NFC400...1200 1NO+1NC 2NO+2NC 2NO+2NC 1NO+1NC 2NO+2NC OZXK12 1) OZXK13 1) OZXK29 2) OZXK1 1) 2) OZXK2 1) 2) 1SCA022144R7400 1SCA022144R7230 1SCA022615R1570 1SCA022131R8690 1SCA022131R8850 0.08 0.12 0.08 0.12 0.12 For switches Number of poles Type Order number Weight [kg] OETL-NFC400 OETL-NFC400 OETL-NFC800...1200 OETL-NFC800...1200 3 4 3 4 OETLZXC17 OETLZXC18 OETLZXC21 OETLZXC22 1SCA022658R9300 1SCA022658R9480 1SCA022658R9720 1SCA022658R9810 0.35 0.40 0.45 0.55 S01414A Terminal shrouds Bridging bars OETLZX17...22 OETLZXC1...10 The bridging bars provide a connection link either on the incoming or outgoing side of the switch. For switches Number of poles Type Order number Weight [kg] OETL-NFC200 OETL-NFC200 OETL-NFC400...600 OETL-NFC400...600 OETL-NFC800 OETL-NFC800 OETL-NFC1200 OETL-NFC1200 3 4 3 4 3 4 3 4 OETLZXC1 OETLZXC2 OETLZXC5 OETLZXC6 OETLZXC7 OETLZXC8 OETLZXC9 OETLZXC10 1SCA022608R0450 1SCA022608R0530 1SCA022608R0880 1SCA022608R0960 1SCA022608R1000 1SCA022608R1180 1SCA022608R1260 1SCA022608R1340 0.6 0.8 1.3 1.8 5.4 7.2 7.5 10.0 S01413A Connection bar For connecting cables using terminal clamp OZXB6. Mounting to bridgingbars OETLZXC_. Bolt kit included. For switches OETLZXC23 OETL-NFC 400...600 1 Type Order number Weight [kg] OETLZXC23 1SCA022659R7580 0.20 Interlocking device for locks Cam attachment for Castell, Lowe & Fletcher or Ronis interlock. Lock not included. Direct mounting to the switch with OH-handle. For switches Type Order number Weight [kg] OETL-NFC200...1200 OETLZWC 1 1SCA022608R1420 1.1 S01518A I ON FF OO OETLZWC 1 1) Suitable for the upper switch. 2) Suitable for the lower switch. 33 1SKC000006C0201 Transfer switches Contact functions and dimension drawings Contact functions for OETL-NFC200…1200 I-Position/ Primary network Load II-Position/ Secondary network 0 I I 0 0 II II 0 Main contacts I Main contacts II Auxiliary contact NO Auxiliary contact NC Auxiliary contact NO S01499A Auxiliary contact NC OETL-NFC200 OETL-NFC200 OETL-NFC200-4 I I 237 M4 155 ØB Ø7 ØB 9x7 45 22 Ø7 9x7 45 22 Ø66 l l 44 O 110 110 102 126 44 O 162 110 102 137 125 4 4 36 45 32 180 260 L S01503A OZXK 29 34 1SKC000006C0201 32 32 F D C 27 A OETL-NFC200_ ØB F A C D I OETL-NFC200 11 25 285 177 56 169 OETL-NFC200-4 11 25 341 233 56 225 OZXK 12 or 13 Shaft OXP 12x 185 250 325 395 465 F D C 27 A OZXK 12 or 13 Mounting depth/L 328...401 393...466 468...541 538...611 608...681 162 137 Transfer switches Dimension drawings OETL-NFC400...600 OETL-NFC400-4 OETL-NFC600-4 OETL-NFC400 OETL-NFC600 295 I I 8 Ø14 25 OZXK 1 or 2 (Upper and Lower Switch) 12 15 165 55 55 Ø66 ØG 13x7 ØG l 17 l 47 O C 140 150 120 172 13x7 55 17 E 47 O C 140 150 120 E 145 H Ø7 Ø7 45 32 D 134 H 216 315 45 36 307 L S01502A B C D E F G H I 316 386 358 448 208 278 253 343 216 216 216 216 70 70 90 90 185 185 185 185 40 40 40 40 13,5 13,5 13,5 13,5 5 5 5 5 182 252 227 317 F 23 B A OZXK 1 or 2 ( Upper and Lower Switch ) Shaft OXP 12x A D 23 OZXK 1 or 2 ( Upper and Lower Switch ) OETL-NFC400_...OETL-NFC600_ OETL-NFC400 OETL-NFC400-4 OETL-NFC600 OETL-NFC600-4 32 F B A Mounting depth/L 357...430 422...495 497...570 567...640 637...710 185 250 325 395 465 OETL-NFC800...1200 OETL-NFC800 OETL-NFC1200 OETL-NFC800-4 OETL-NFC1200-4 I I 297 9x17 14 24 15 12 9x17 Ø9 14 195 24 15 Ø9 Ø66 95 95 190 254 373 I O 190 254 373 333 I O 333 212 175 39,5 20 39,5 20 D 40 215 61 315 L 59 59 50 C 17 B 52,5 A 410 500 410 500 B 298 388 298 388 B 17 A OZXK 1 or 2 ( Upper and Lower Switch ) OETL-NFC800_...1200_ OETL-NFC800 OETL-NFC800-4 OETL-NFC1200 OETL-NFC1200-4 50 C 52,5 A OZXK 1 or 2 ( Upper and Lower Switch ) S01504A 36 C 90 90 90 90 D 12 12 16 16 I 267 357 267 357 Shaft OXP 12x 185 250 325 395 465 Mounting depth/L 364...437 429...502 504...577 574...647 644...717 35 1SKC000006C0201 Open transition switches Closed transition switches Maintenance bypass for UPS The OESC range is a “make before break” i.e. Closed Transition Transfer Switch type that guarantees a transfer from the static switch to the power line as manual bypass switch and back again without any interruption. This ensures equipment is powered, even when maintenance work is carried out. The OESC switches have double rated neutral to withstand the thermal overload from the harmonics, normally produced by the UPS and added up in the neutral conductor. The range is UL 508 Recognized. I-Position/ Primary network Load Main contacts I Main contacts II 36 II-Position/ Secondary network Transfer switches Technical data and contact functions Data according to UL508 (Recognized) Switch size General use Voltage Current Short circuit current r.m.s OESC 250K_ 500K_ 250K04N2 400K04N2 V A kA 480 250 50 480 500 50 480 250 1) 50 480 400 2) 50 V kV kV A mm2 V A A kA 1 000 8 12 250 120 1 000 250 250 42 1 000 8 12 500 2x 120 1 000 500 500 42 1000 8 12 250 120 1000 250 1) 250 1) 42 1000 8 12 400 240 1000 400 2) 400 2) 42 Oper. 16 000 16 000 16 000 16 000 mm Nm Nm M10x40 30...44 30 M10x40 30...44 30 M10x40 30...44 M10x40 30...44 Data according to IEC 60947-3 Rated insulation voltage Pollution degr. 3 Dielectric strength 50 Hz 1min. Rated impulse withstand voltage Rated thermal current in ambient 40 ° C In open air ...with minimum cable cross section Cu Rated operational voltage AC-20 and DC-20 Rated operational current, AC-21A 500 V Rated operational current, AC-22A 500 V Rated conditional short-circuit current Ip (r.m.s.) Ip : 50 kA/ ≤ 500 V and corresponding max. allowed cut-off current îc, peak value. Mechanical endurance Divide by two for operation cycles Terminal bolt size Diameter x length Terminal tightening torque Counter torque required Operating torque 3-pole switches 1) 2) Powerpoles 250 A; Neutral 400 A, with minimum cable cross section 240 mm2. Powerpoles 400 A; Neutral 630 A, with minimum cable cross section 2 x 185 mm2. Contact functions for OESC250...500 I-Position/ Primary network Load II-Position/ Secondary network I II II I Main contacts I Main contacts II S01498A Auxiliary contact NO Auxiliary contact NC 37 1SKC000006C0201 Transfer switches Ordering information Transfer switches, 3-pole, I-II -operation The switch includes a black handle IP65, see the table below, shaft and bolt set for the cable connection. The bridging bars between the load supplies are also included. 21 13 21 13 Rated current I[A] AC-21A...AC-22A, 400V Type Order number Weight [kg] 250 500 OESC250K03 OESC500K03 1SCA022700R2270 1SCA022700R2350 12.0 12.0 S01496A Transfer switches, 4-pole, I-II -operation The switch includes a black handle IP65, shaft and bolt set for the cable connection. The bridging bars between the load supplies are also included. OESC_K03 21 13 21 13 Rated current I[A] AC-21A...AC-22A, 400V Type Order number Weight [kg] 250 500 OESC250K04 OESC500K04 1SCA022700R2510 1SCA022700R2600 14.6 14.6 Transfer switches, 4-pole, double rated neutral, I-II -operation S01497A The switch includes a black handle IP65, shaft and bolt set for the cable connection. The bridging bars between the load supplies are also included. Rated current I[A] AC-21A...AC-22A, 400V Type 250/ 400 400/ 630 OESC250K04N2 1SCA022703R9940 OESC400K04N2 1SCA022704R0010 Order number Weight [kg] 15.2 15.2 OESC_K04 External handles, IP 65, indication I - II 21 13 21 13 The handles are equipped with door interlock function in II-position and when padlocked, only in I -position. Padlocking with 3 padlocks, bail dia Ø5...10 mm. S01497A Padlocking possibility in I -position For switches Colour OESC 250...500 OESC_K04N2 Black Black Order number OHB175J12E16 1SCA022692R2080 OHB275J12E16 1SCA022690R0350 Weight [kg] 0.17 0.17 Extended shafts For switches Length [mm] Type Order number Weight [kg] OESC 250…500 395 465 OXP12x395 OXP12x465 1SCA022042R5990 1SCA022042R6020 0.45 0.53 I II S01575A Type Auxiliary contacts Wire cross section 0.5 mm2...2 x 2.5 mm2. Insulation voltage Ui 690 V. Thermal current Ith = 10 A. Protection degree IP 20. Contact functions, see the previous page. OH_ S00047A Performance data according to IEC 60947-5-1 Ue /Ie (AC12):120V/8A, 240V/6A, 400V/4A, 415V/4A, 480V/3A, 500V/3A, 690V/2A, Ue /Ie (DC12): 125V/1.1A, 250V/0.55A, 440V/0.31A, 500V/0.27A, 600V/0.2A. Auxiliary contact OXP12X_ S01275A 21 Type Order number Weight [kg] OESC OZXK 1 1SCA022131R8690 0.09 OZXK 2 1SCA022131R8850 0.12 OZXK 4 1SCA022131R9230 0.09 OZXK 5 1SCA022131R9400 0.12 250...500 22 34 13 21 33 41 13 For switch sizes 21 33 OESC 250...500 14 22 34 42 23 33 2no 250...500 24 34 13 23 33 43 4no 14 24 34 44 OZXK1...5 OESC OESC 250...500 Shafts and handles included as standard The handle is equipped with door interlock function in II-position and when padlocked, only in I -position. Padlocking with 3 padlocks, bail dia Ø 5...10 mm. Indication I-II. 38 1SKC000006C0201 For switches Shaft Handle Terminal bolt set OESC 250...500 OXP12x250 OHB275J12E16 M10x40 Transfer switches Dimension drawings OESC250...500, 3-pole 5 Ø7 75 76 S01510A 230 119 210 177 232 30 44 Ø12 88 4 62 80 25 348 206 237 30 177 166 OESC250...500, 4-pole Ø7 5 75 Ø 11 77 230 210 119 177 232 30 C 48 A A 92 62 A B Ø12 80 380 206 410 237 S01511A 30 166 177 AxC BxC OESC 250K04 25x4 25x4 OESC 500K04 25x4 25x4 OESC 250K04N2 25x4 25x4 OESC400K04N2 25x4 30x8 39 1SKC000006C0201 Rotary change-over and bypass cam switches The rotary cam switches are the most space saving changeover solutions, for the door and modular base mounting. The standard range includes a black handle and finger protected terminals. A large variation of front plates for customized engraving enables special cam switches. Special cam switches can be configurated on the Internet by the Camweb configurator. The specification and ordering of special cam switches is as easy as selecting standard products! 40 Rotary change-over cam switches Technical data Ratings according to IEC60947 Impuls withstand voltage Rated insulation voltage Rated operational voltage Rated thermal current Ith Rated conditional short circuit current Max back-up fuse link Rated short time withstand current (r.m.s) Uimp Ue Ip (r.m.s.) 3s 10s 30s 60s Rated operational current Ie AC1 AC21 AC11 AC22 Size OM ON OL40 OL80 OL125 OL160 OL200 kV 2.5 4 6 6 6 6 6 V V A kA 500 250 10 1 690 400 25 - 690 690 45 - 690 690 115 - 690 690 150 5 690 690 175 5 690 690 280 10 A A 10 25 100 40 360 125 800 200 1280 200 1280 250 1600 200 120 80 45 45 45 14 6.0 7.0 40 40 420 260 160 115 115 115 30 30 28 100 80 700 400 280 150 150 150 45 45 40 150 100 700 400 280 160 170 170 45 45 40 170 100 1000 600 400 250 250 250 80 80 70 250 125 400V 400V 220-240V 380-440V 500V 220-500V 660-690V A A A A A A A A A A A 10 10 10 2.5 10 - 60 32 30 25 25 25 5.5 3.5 4.5 20 20 Rated operational current Time constant 0...1ms DC1 24V 48V 60V 110V 220V 440V A A A A A A 10 6 2.5 0.7 0.3 - 20 10 3 0.8 0.4 0.22 40 20 5 1 0.6 0.25 115 100 - 130 115 - 150 130 - 250 200 - Rated operational current Time constant 1...50 ms DC1 24V 30V 40V 60V 110V A A A A A 6 3 1 0.7 0.3 10 4.5 1.7 0.8 0.4 32 11 4 1.5 0.6 100 33 - 115 36 - 130 40 - 200 50 - 220-240V 380-440V 500V 660-690V 110V 220-240V 400V kW kW kW kW kW kW kW 1.8 3 0.37 0.75 1.1 2.6 7.5 4.8 4.8 0.5 0.9 1.5 7.5 15 15 15 2.5 4 7.5 30 45 55 45 5.5 15 22 37 75 75 50 9 20 35 37 75 90 55 11 22 37 56 75 85 90 14 30 45 220-240V 380-440V 500V 660-690V kW kW kW kW 2.5 - 3.5 6 6 6 11 18.5 18.5 18.5 30 45 55 55 35 50 65 65 37 55 75 55 70 95 103 110 Rated operational power AC23 3 ph. AC23 1 ph. Rated operational power AC2 3 ph. 41 1SKC000006C0201 Rotary change-over cam switches Technical data Ratings according to IEC60947 Size OM ON OL40 OL80 OL125 OL160 OL200 AC3 3 ph. 220-240V 380-440V 500V 660-690V kW kW kW kW 1.8 2.2 - 2.2 5.5 4 4 7.5 11 11 11 15 30 30 30 20 35 35 30 22 37 37 30 47 64 82 88 AC3 1 ph. 110V 220-240V 400V kW kW kW 0.3 0.55 0.75 0.4 0.75 1.3 2.5 4.0 5.5 3.7 7.5 13 6 11 19 6 11 19 12 24 40 Size OM ON OL40 OL80 OL125 OL160 OL200 M mm2 AWG 2.5 1.5 14 3.5 4 14-12 5 6 14-8 5 70 12-2/0 5 70 12-2/0 5 70 12-2/0 10 150 kcmil 300 Size OM ON OL40 OL80 OL125 OL160 OL200 CSA/UL V VAC 300 A300 600 A600 600 A600 600 A600 600 A600 600 A600 600 A600 CSA UL 120V 240V 480V 600V 120V 240V 480V 600V A A HP HP HP HP HP HP HP HP 10 10 1 1 0.33 1 - 25 25 1 2 5 5 1 1 2 3 40 40 5 10 20 20 2 3 10 10 80 80 10 30 30 30 7.5 15 - 125 125 15 40 40 40 10 20 - 170 170 15 40 50 50 10 20 - 200 200 32 64 120 120 10 kA A cycles/ hour 1 16 150 10 35(RK5) 150 10 50(RK3) 150 Terminals Connecting screws Max cable cross section Ratings according to UL and CSA Maximum operating voltage Pilot duty category Ampere rating General use at 600VAC Rated power 3-phase 1-phase Short cicuit ratings Maximum prospective fault current Maximum fuse size Switching frequency 42 1SKC000006C0201 10 10 10 10 100(RK5) 150(RK5) 200(RK5) 250(RK5) 150 150 150 150 Rotary change-over cam switches Ordering information Change-over switches Black handle and front plate with position indication are included. The type and the ordering number are for one piece. Function Number of poles Type Order number Delivery batch [pcs] Weight/ unit [kg] Step angle 60°, with 0-position Door mounted 1-0-2 1 10 2 10 3 10 4 10 1-0-2 1 25 2 25 3 25 4 25 1-0-2 1 45 2 45 3 45 4 45 1-0-2 1 115 2 115 3 115 4 115 1-0-2 1 150 2 150 3 150 4 150 1-0-2 1 175 2 175 3 175 4 175 1-0-2 1 280 2 280 3 280 4 280 OMU1PB OMU2PB OMU3PB OMU4PB ONU1PB ONU2PB ONU3PB ONU4PB OL40U1PB OL40U2PB OL40U3PB OL40U4PB OL80U1RB OL80U2RB OL80U3RB OL80U4RB OL125U1RB OL125U2RB OL125U3RB OL125U4RB OL160U1RB OL160U2RB OL160U3RB OL160U4RB OL200U1RB OL200U2RB OL200U3RB OL200U4RB 1SCA022532R5960 1SCA022532R6000 1SCA022532R6180 1SCA022532R6260 1SCA022532R7310 1SCA022532R7400 1SCA022532R7580 1SCA022532R7660 1SCA022761R0990 1SCA022761R1020 1SCA022761R1110 1SCA022761R1290 1SCA022790R0560 1SCA022790R0640 1SCA022790R0720 1SCA022790R0810 1SCA022790R1960 1SCA022790R2000 1SCA022790R2180 1SCA022790R2260 1SCA022790R6840 1SCA022790R6920 1SCA022790R7060 1SCA022790R7140 1SCA022790R7220 1SCA022790R7310 1SCA022790R7490 1SCA022790R7570 10 10 10 10 10 10 10 10 10 10 10 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.09 0.11 0.13 0.14 0.09 0.11 0.13 0.14 0.17 0.25 0.33 0.41 0.34 0.45 0.56 0.67 0.34 0.45 0.56 0.67 0.34 0.45 0.56 0.67 2.00 3.10 4.20 5.30 DIN-rail mounted 1-0-2 1 2 3 4 ONU1M ONU2M ONU3M ONU4M 1SCA022532R8210 1SCA022532R8390 1SCA022532R8470 1SCA022534R2710 10 10 10 10 0.09 0.11 0.13 0.14 Key operated, with 0-position, withdrawable in all positions, step angle 60° Door mounted 1-0-2 1 10 OMU1KB 1SCA022532R6340 3 10 OMU3KB 1SCA022532R6420 1-0-2 1 25 ONU1KB 1SCA022532R7740 3 25 ONU3KB 1SCA022532R7820 10 10 10 10 0.07 0.08 0.12 0.13 1R- 0 - 2R , with two sided spring return, step angle 60° Door mounted 10 OMURR1PB 1SCA022532R6510 1R - 0 - 2R 1 3 10 OMURR3PB 1SCA022532R6690 25 ONURR1PB 1SCA022532R7910 1R - 0 - 2R 1 2 25 ONURR2PB 1SCA022558R4040 3 25 ONURR3PB 1SCA022532R8040 45 OL40URR1PB 1SCA022761R1370 1 R - 0 - 2R 1 2 45 OL40URR2PB 1SCA022761R1450 3 45 OL40URR3PB 1SCA022761R1530 10 10 10 10 10 10 10 10 0.05 0.06 0.09 0.11 0.12 0.17 0.25 0.33 DIN-rail mounted 1 R - 0 - 2R 1 10 0.09 O_U1_ O_U2_ O_U3_ O_U4_ O_URR1_ O_URR2_ O_URR3_ Rated thermal current Ith [A] 25 25 25 25 25 Packing sizes for 10 pcs: OM ON, OL40 ONURR1M 1SCA022568R3530 130 x 100 x 120 [mm] 250 x 100 x 110 [mm] 43 1SKC000006C0201 Rotary change-over cam switches Ordering information Change-over switches Black handle and front plate with position indication are included. The type and the ordering number are for one piece. Function O_WS1_ O_WS2_ O_WS3_ O_WS4_ Number Rated of thermal poles current Ith [A] Type Order number Delivery batch [pcs] Weight/ unit [kg] Without 0-position, step angle 60° Door mounted 1-2 1 10 2 10 3 10 4 10 1-2 1 25 2 25 3 25 4 25 1-2 1 45 2 45 3 45 4 45 1-2 1 115 2 115 3 115 4 115 1-2 1 150 2 150 3 150 4 150 1-2 1 175 2 175 3 175 4 175 1-2 1 280 2 280 3 280 4 280 OMWS1PB OMWS2PB OMWS3PB OMWS4PB ONWS1PB ONWS2PB ONWS3PB ONWS4PB OL40WS1PB OL40WS2PB OL40WS3PB OL40WS4PB OL80WS1RB OL80WS2RB OL80WS3RB OL80WS4RB OL125WS1RB OL125WS2RB OL125WS3RB OL125WS4RB OL160WS1RB OL160WS2RB OL160WS3RB OL160WS4RB OL200WS1RB OL200WS2RB OL200WS3RB OL200WS4RB 1SCA022532R6770 1SCA022532R6850 1SCA022533R0610 1SCA022533R0700 1SCA022532R8120 1SCA022532R9360 1SCA022532R9440 1SCA022532R9520 1SCA022761R1610 1SCA022761R1700 1SCA022761R1880 1SCA022761R1960 1SCA022790R0990 1SCA022790R1020 1SCA022790R1110 1SCA022790R1290 1SCA022790R2340 1SCA022790R2420 1SCA022790R2510 1SCA022790R2690 1SCA022790R8030 1SCA022790R8110 1SCA022790R8200 1SCA022790R8380 1SCA022790R8460 1SCA022790R8540 1SCA022790R8620 1SCA022790R8710 10 10 10 10 10 10 10 10 10 10 10 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.09 0.11 0.13 0.14 0.09 0.11 0.13 0.14 0.17 0.25 0.33 0.41 0.34 0.45 0.56 0.67 0.34 0.45 0.56 0.67 0.34 0.45 0.56 0.67 2.00 3.10 4.20 5.30 DIN-rail mounted 1-2 1 2 3 4 ONWS1M ONWS2M ONWS3M ONWS4M 1SCA022532R8710 1SCA022532R8800 1SCA022532R8980 1SCA022532R9010 10 10 10 10 0.09 0.11 0.13 0.14 25 25 25 25 Wiring diagram (O_WS_) Packing sizes for 10 pcs: OM ON, OL40 44 1SKC000006C0201 130 x 100 x 120 [mm] 250 x 100 x 110 [mm] Rotary change-over cam switches Ordering information Change-over switches Black handle and front plate with position indication are included. The type and the ordering number are for one piece. Function O_WC1_ O_WC2_ O_WC3_ O_WC4_ O_UC3_ O_UC4_ Number Rated of thermal poles current Ith [A] Type Order number Delivery batch [pcs] Weight/ unit [kg] OMWC1PB OMWC2PB OMWC3PB OMWC4PB ONWC1PB ONWC2PB ONWC3PB ONWC4PB OL40WC1PB OL40WC2PB OL40WC3PB OL40WC4PB OL80WC1RB OL80WC2RB OL80WC3RB OL80WC4RB 1SCA022799R8270 1SCA022799R8600 1SCA022799R9080 1SCA022799R9160 1SCA022799R8350 1SCA022799R8780 1SCA022799R9240 1SCA022799R9320 1SCA022799R8430 1SCA022799R8860 1SCA022799R9410 1SCA022799R9590 1SCA022799R8510 1SCA022799R8940 1SCA022799R9670 1SCA022799R9750 10 10 10 10 10 10 10 10 10 10 10 10 1 1 1 1 0.09 0.11 0.13 0.14 0.09 0.11 0.13 0.14 0.17 0.25 0.33 0.41 0.34 0.45 0.56 0.67 With common center position and with overlapping contacts 1 - (1 + 2) - 2 3 25 ONUC3PB 1SCA022791R0360 4 25 ONUC4PB 1SCA022791R0280 1 - (1 + 2) - 2 3 45 OL40UC3PB 1SCA022791R0870 4 45 OL40UC4PB 1SCA022791R0950 1 - (1 + 2) - 2 3 115 OL80UC3RB 1SCA022791R1410 4 115 OL80UC4RB 1SCA022791R1920 1 - (1 + 2) - 2 3 150 OL125UC3RB 1SCA022791R1500 4 150 OL125UC4RB 1SCA022791R2060 1 - (1 + 2) - 2 3 175 OL160UC3RB 1SCA022791R1680 4 175 OL160UC4RB 1SCA022791R2140 1 - (1 + 2) - 2 3 280 OL200UC3RB 1SCA022791R1760 4 280 OL200UC4RB 1SCA022791R2220 10 10 10 10 1 1 1 1 1 1 1 1 0.13 0.14 0.13 0.14 0.56 0.67 0.56 0.67 0.56 0.67 4.20 5.30 Door mounted With overlapping contacts 1-2 1 10 2 10 3 10 4 10 1-2 1 25 2 25 3 25 4 25 1-2 1 45 2 45 3 45 4 45 1-2 1 115 2 115 3 115 4 115 Wiring diagram (O_WC_, O_UC_) Packing sizes for 10 pcs: OM ON, OL40 130 x 100 x 120 [mm] 250 x 100 x 110 [mm] 45 1SKC000006C0201 Rotary change-over cam switches Ordering information Bypass switches Black handle and front plate with position indication are included. The type and the ordering numberare for one piece. Function Order number Delivery batch [pcs] Weight/ unit [kg] Without overlapping, 3 and 4- pole network 1 - 0 - Bypass 3 / 6 25 ONWS36PB 4/8 25 ONWS48PB 1 - 0 - Bypass 3 / 6 45 OL40WS36PB 4/8 45 OL40WS48PB 1 - 0 - Bypass 3 / 6 115 OL80WS36RB 4/8 115 OL80WS48RB 1 - 0 - Bypass 3 / 6 150 OL125WS36RB 4/8 150 OL125WS48RB 1 - 0 - Bypass 3 / 6 175 OL160WS36RB 4/8 175 OL160WS48RB 1 - 0 - Bypass 3 / 6 280 OL200WS36RB 4/8 280 OL200WS48RB 1SCA022791R0440 1SCA022791R0520 1SCA022791R1090 1SCA022791R1170 1SCA022791R2490 1SCA022791R2900 1SCA022791R2570 1SCA022791R3030 1SCA022791R2650 1SCA022791R3110 1SCA022791R2730 1SCA022791R3200 10 10 10 10 1 1 1 1 1 1 1 1 0.17 0.19 0.21 0.31 0.78 0.89 0.78 0.89 0.78 0.89 6.40 7.50 With overlapping, 3 and 4- pole network 1 - Bypass 3/6 25 ONPW36PB 4/8 25 ONPW48PB 1 - Bypass 3/6 45 OL40PW36PB 4/8 45 OL40PW48PB 1 - Bypass 3/6 115 OL80PW36RB 4/8 115 OL80PW48RB 1 - Bypass 3/6 150 OL125PW36RB 4/8 150 OL125PW48RB 1 - Bypass 3/6 175 OL160PW36RB 4/8 175 OL160PW48RB 1 - Bypass 3/6 280 OL200PW36RB 4/8 280 OL200PW48RB 1SCA022791R0610 1SCA022791R0790 1SCA022791R1250 1SCA022791R1330 1SCA022791R3460 1SCA022791R3970 1SCA022791R3540 1SCA022791R4010 1SCA022791R3620 1SCA022791R4190 1SCA022791R3710 1SCA022791R4270 10 10 10 10 1 1 1 1 1 1 1 1 0.17 0.19 0.21 0.31 0.78 0.89 0.78 0.89 0.78 0.89 6.40 7.50 O_WS36_ Number of poles Rated thermal current Ith [A] Type Door mounted O_WS48_ O_PW36_ O_PW48_ Wiring diagram, bypass switches Phase 1 Phase 2 Phase 3 O_WS36_, O_PW36_ O_WS48_, O_PW48_ Packing sizes for 10 pcs: 46 1SKC000006C0201 OM ON, OL40 130 x 100 x 120 [mm] 250 x 100 x 110 [mm] Phase 4 Accessories Ordering information Handles The type and the ordering number are for one piece. Colour OMPB1 ONPB1 OMPG1 ONPG1 For cam switches Type Oder Number Delivery Weight/ batch unit [pcs] [kg] Snap on handle with front plate without engraving (The black handle is standard delivery in types OM, ON, and OL40) Size 30x30 Black Gray Red Red-yellow OM OM OM OM OMPB1 OMPG1 OMPR1 OMPRY1 1SCA022553R7470 1SCA022553R8010 1SCA022796R2830 1SCA022796R2910 5 5 5 5 0.05 0.05 0.05 0.05 Size 48x48 Black Gray Red Red-yellow ON_PB, OL40 ON_PB, OL40 ON_PB, OL40 ON_PB, OL40 ONPB1 ONPG1 ONPR1 ONPRY1 1SCA022553R7550 1SCA022553R7630 1SCA022796R3050 1SCA022796R3130 5 5 5 5 0.08 0.08 0.08 0.08 5 5 5 5 0.10 0.10 0.10 0.10 Snap on handle with large front plate without engraving ONPLB1 OLR2B, OLR3B Size 64x64 Black Gray Red Red-yellow ON_PB, OL40 ON_PB, OL40 ON_PB, OL40 ON_PB, OL40 ONPLB1 ONPLG1 ONPLR1 ONPLRY1 1SCA022776R5680 1SCA022776R5760 1SCA022776R5840 1SCA022796R3130 Screw mounting handle with front plate without engraving (The black handle is standard delivery in types OL 80...200) OMXB1 ONXB1 Size 90x90 Black Gray Red OL80, OL125, OL160 OLR2B OL80, OL125, OL160 OLR2G OL80, OL125, OL160 OLR2R 1SCA022796R3720 1SCA022796R3810 1SCA022796R3990 10 10 10 0.10 0.10 0.10 Size 130x130 Black Gray Red OL200 OL200 OL200 1SCA022796R4110 1SCA022796R4290 1SCA022796R4370 10 10 10 0.10 0.10 0.10 5 5 5 0.02 0.02 0.02 OLR3B OLR3G OLR3R Snap on handle with round escutheon plate Black OM Black, nose-type OM Black ON_PB, OL40 OMXB1 OMXNB1 ONXB1 1SCA022629R7270 1SCA022577R9810 1SCA022629R7350 More cam switches with padlockable handles can be configurated on Internet by the Camweb configurator tool. 47 1SKC000006C0201 Accessories Ordering information Optional handles The type and the ordering number are for one piece. Colour For cam switches Type Oder Number OLHSD1 Delivery Weight/ batch unit [pcs] [kg] Hand grip handle, screw mounting Black Gray Red OLHSD1 OLHGD1 OLHRD1 1SCA022765R2480 1SCA022765R2560 1SCA022765R2640 Ball grip handle, screw mounting OLISD1 Black Gray Red OLISD1 OLIGD1 OLIRD1 1SCA022820R3380 1SCA022820R3460 1SCA022820R3540 Pistol type handle, screw mounting Black Red Black Red OLZ2RB OL80, OL125, OL160 OL80, OL125, OL160 OL200 OL200 OLZ2RB OLZ2RR OLZ3RB OLZ3RR 1SCA022796R4530 1SCA022796R4610 1SCA022796R4700 1SCA022796R4880 10 10 10 10 0.10 0.10 0.2 0.2 1SCA022796R4960 1SCA022796R5000 1 1 0.3 0.3 Double lever handle, screw mounting Black Red OLZ3RB OL200 OL200 OLZ3DB OLZ3DR Padlockable handle knob, without front plate The standard handle knob is replaced by the padlockable handle knob. For max 2 padlocks of 6 mm hasp diameter. Standard padlocking in the OFF-position at 9 o’clock. Padlocking in the ON-position (12 o’clock) by turning the control piece 180 degrees. Padlocking in both OFF-and ON-positions by removing a precut in the yellow control piece. Black ON_PB, ON_M, OL40 ONZ20B 1SCA022621R1810 5 0.06 Red-yellow ON_PB, ON_M, OL40 ONZ20RY 1SCA022621R1900 5 0.06 OLZ3DB Round padlockable handle for srew mounting on door ONZ20B ONZ20RY For max 3 padlocks with max 8 mm hasp diameter, locking position 9 o’clock (O, OFF) and positions 12 o’clock (1, ON) when switch rotated. More locking possibilities with programmable square handle type _ 5 _ can be specified by the Camweb tool. Size 64x64, shaft size 6 mm Black ON_PB, OL40 ONZ331PB 1SCA022794R7520 10 0.035 Red-yellow ON_PB, OL40 ONZ331PRY 1SCA022794R7610 10 0.035 Size 90x90, shaft size 8 mm Black OL80, OL125, OL160 OLZ332RB Red-yellow OL80, OL125, OL160 OLZ332RRY ONZ331PB 1SCA022794R7790 1SCA022794R7870 10 10 ONZ332RRY More cam switches with padlockable handles can be configurated on Internet by the Camweb configurator tool. 48 1SKC000006C0201 0.10 0.10 Accessories Ordering information Front plates The type and the ordering number are for one piece. Colour OMF101 ONF64 For cam switches/ handle size Type Order Number ONF101 OLF90 ONFM101 Delivery Weight/ batch unit [pcs] [kg] Front plates, without engraving Size 30x30 Silver OM/OMP_1 Yellow OM/OMPR41 OMF101 1SCA022540R4590 OMFY101 1SCA022796R3210 10 10 0.003 0.003 Size 48x48 Silver Yellow ON_PB, OL 40/ONP_1 ON_PB, OL 40/ONPRY1 ONF101 1SCA022540R6290 ONFY101 1SCA022716R4250 10 10 0.003 0.003 Size 64x64 Silver Yellow ONPL_1 ONPLR41 OLF64 OLF464 1SCA022798R6260 1SCA022798R6340 10 10 0.003 0.003 Size 90x90 Silver Yellow OL80, OL125, OL160/OLR2_ OLF90 OL80, OL125, OL160/OLR2_ OLFY90 1SCA022796R5180 1SCA022796R5260 10 10 0.01 0.01 Size 130x130 Silver Yellow OL200/OLR3_ OL200/OLR3_ OLF130 1SCA022796R5420 OLFY130 1SCA022796R5340 10 10 0.01 0.01 ONFM 101 1SCA022553R8520 10 0.01 Without engraving, black engraving from front side available. Size 30x30 Black frame OM OMFB72 1SCA022555R4990 Grey frame OM OMFG72 1SCA022556R1850 5 5 0.01 0.01 Size 48x48 Black frame Grey frame ON_PB, OL 40 ON_PB, OL 40 ONFB72 ONFG72 1SCA022555R5020 1SCA022556R1930 5 5 0.01 0.01 Size 64x64 Black frame Grey frame ON_PB, OL 40 ON_PB, OL 40 OLFB64 OLFG64 1SCA022796R3300 1SCA022796R3480 10 10 0.01 0.01 OM ON_PB, OL40 OMX99 ONX99 1SCA022553R8100 1SCA022553R7710 10 10 0.01 0.01 Size H=45mm, W=54mm Grey ON_M Additional lettering plates OMFB72 ONFB72 ONFB64 Front ring Black Black OMX99 ONX99 Shaft sealing To prevent dust and moisture penetrating along the switch shaft when no handle is installed. Protection to IP 65 from the front. Door drilling 16...17 mm. For cam switches Type Order Number Delivery Weight batch [kg] [pcs] ON, OL40 OL 80...160 ONZ11 OLZ12 1SCA022807R0300 1SCA022807R0560 10 10 0.01 0.01 49 1SKC000006C0201 Accessories Ordering information Other accessories The type and the ordering number are for one piece. OMK95 ONK95 Spare key Number of keys included For cam switches Type Order number Delivery Weight batch [kg] [pcs] 2 pcs 3 pcs OM ON, OL40 OMK95 ONK95 1SCA022553R8360 1SCA022553R7980 2 2 0.01 0.01 Protective rear cover ONZ10L_ Transparent, IP 42 protection OMNX80 ONX30 Number Number of of chambers contacts For cam switches Type Order number Delivery Weight batch [kg] [pcs] 1-2 3-4 5-6 2 4 6 2 4 6 ON ON ON OL40 OL40 OL40 OL80...160 OL80...160 OL80...160 ONZ10L2 ONZ10L4 ONZ10L6 OLZ401L2 OLZ401L4 OLZ401L6 OLZ1601L2 OLZ1601L4 OLZ1601L6 1SCA022621R1570 1SCA022621R1650 1SCA022621R1730 1SCA022805R9910 1SCA022806R0090 1SCA022806R0170 1SCA022806R0250 1SCA022806R0330 1SCA022806R0410 1 1 1 1 1 1 1 1 1 2-4 6-8 10-12 0.02 0.04 0.06 Nut spanner ONZ37 for mounting the handle to the door Colour For cam switches Type Order number Delivery Weight batch [kg] [pcs] OM ON OMNX80 1SCA022553R8440 1 0.02 Black 10 0.01 Adaptor ring for fixing the snap-on handles in the 30 mm door drilling. Black ON ONX30 1SCA022643R8510 ONZ74_ Base mounting kit Includes base for DIN-rail mounting, shaft adaptor and 200 mm shaft for cutting up to 250 mm panel depth. Depth [mm] For cam switches Type Order number 250 ON ONZ74 1SCA022757R3510 ONZ37 1SCA022789R8810 0.05 DIN-Rail mounting plate ONZ45P ONZ65_ 50 1SKC000006C0201 Includes base for DIN-rail mounting. ON 1 0.02 Door coupling kits for base mounting switches for snap-on mounted handle. ON, OL40 ONZ45P 1SCA022819R5850 1 0.01 for screw mounted handle. OL80...160 OL200 OLZ652 OLZ653 1SCA022819R5930 1SCA022819R6070 1 1 0.02 0.02 Rotary change-over cam switches Dimension drawings OM 2 3, 8 3,2 + 0,2 17,9 16,2 12 Screw mounted handle (special) 20 1,7 L 25 Ø 27x28 + 0,2 Door thickness max. 5,5 mm 7 + 0,4 + 0,2 24,1 + 0,2 22,3 12 + 0,4 27x28 28 21,5 S01158Agb 30 Door thickness max. 5,5 mm 51,5 22 L 30 Number of contact chambers 1 2 3 4 5 6 7 8 Snap-on mounting (P type) L 45 57 69 81 90 105 117 129 Screw mounting (R type) L 33 45 57 69 81 93 105 117 ON Number of contact chambers Snap-on mounting (P type) Screw mounting (R type) 1 2 3 4 5 6 7 8 9 10 L 54 66 78 90 102 114 126 138 150 162 L 34 46 58 70 82 94 106 118 130 142 H 62 74 86 98 110 122 134 146 159 171 51 1SKC000006C0201 Rotary change-over cam switches Dimension drawings ON_M 53 5 35 16 17 12 S001159A 45 39x41 13,5 46 Non-modular: number of contact chambers L 2 3 4 5 6 7 8 58 70 82 94 106 118 130 OL40, door mounted with snap-on mounting handle Number of contact chambers L 52 1SKC000006C0201 1 2 3 4 5 6 7 8 9 10 59 72 85 98 111 124 137 150 163 176 Rotary change-over cam switches Dimension drawings OL80, OL125, OL160 door mounted Number of contact chambers L 1 2 3 4 5 6 7 8 9 10 66 97 128 159 190 221 252 283 314 345 OL200 door mounted Number of contact chambers L 1 2 3 4 5 6 7 8 9 10 120 181 242 303 364 425 486 547 608 669 53 1SKC000006C0201 Notes 54 1SKC000006C0201 Notes 55 1SKC000006C0201 Printed by: Waasa Graphics Oy, Vaasa Finland Producted by: Citec Information OY, Vaasa Finland Catalogue OT_OETL2GB 06_06 1SCC301007C0201 ABB Oy Low Voltage Products P.O. Box 622 FI-65101 VAASA, Finland Telephone +358 10 22 11 Telefax +358 10 22 45708 www.abb.com/lvswitches The technical data and dimensions are valid at the time of printing. We reserve the right to subsequent alterations. The operations of the manufacturing plant have been certified.