muirfield mse - Teron Lighting

advertisement

Project:

Type:

Ordering # :

Comments:

ARCHITECTURAL VANITY

MUIRFIELD

MSE

LINEAR FLUORESCENT

FEATURES

• Steel Housing w/ White Powder Coat Finish

• Steel Mounting Pan w/ Hi-Reflectance White Powder Coat Finish

• Steel End Caps w/ White Powder Coat Finish

• Clear Acrylic Lens w/ Ribbed Sides and Prismatic Front

• Mounts Directly to Surface w/ Two Wall Anchors (Not Included)

• Integral EM Battery Available (3’ & 4’ Fixtures Only)

• Lamps Not Included

• Convenience Outlet & Pull Chain Available

• ETL Listed Damp Location

OPTIONAL MOTION SENSORS

• The FS-505 is an External Motion Sensor Contained in an Attached Compartment

- To be Mounted Horizontally on Wall

(See Page 5 For Manufacturer Specific Application & Coverage Patterns.)

• The HFLUM2-WR is an Internal Microwave Motion Sensor

- May be Mounted on Wall or Ceiling

(See Page 6 For Manufacturer Specific Application & Coverage Patterns)

ORDERING INFORMATION

White is Standard Finish Example : (MD48232E - 120E - SDIM40 - MSE)

PRODUCT SOURCE/WATTAGE

Muirfield

24” Fixture

MD24117E - (1) 17W T8

MD24217E - (2) 17W T8

MD24214E - (2) 14W T5

Muirfield

36” Fixture

Muirfield

48” Fixture

MD36125E - (1) 25W T8

MD36225E - (2) 25W T8

MD36221E - (2) 21W T5

MD48132E - (1) 32W T8

MD48232E - (2) 32W T8

MD48228E - (2) 28W T5

VOLTAGE

120E - 120V Electronic

277E - 277V Electronic

347E - 347V Electronic

DIMMING CONFIG

SDIM10** - Lamps Set at 10% Output w/ No Occupancy & 100% Outout w/ Motion Sensor Occupancy Read

(See Pg. 3) (120V / 277V Only)

SDIM40** - Lamps Set at 40% Output w/ No Occupancy & 100% Outout w/ Motion Sensor Occupancy Read

(See Pg. 3) (120V / 277V Only)

SDIM50** - Lamps Set at 50% Output w/ No Occupancy & 100% Outout w/ Motion Sensor Occupancy Read

(See Pg. 3) (120V / 277V Only)

MS2B - 1 Lamp at 100% Constant

Output, and 1 Lamp Connected to

Motion Sensor (Requires 2 Ballasts)

Please Refer to Page 2 for Step-Dim &

MS2B Specifications, Options, and

Restrictions

FINISH

CH - Chrome Plated

SM - Matte Silver

TB - Textured Black

AC - Antique Copper

AS - Antique Silver

BT - Bronze Mist

CP - Copper

KC - Kenworth Chrome

SN - Sand

SW - Swedish Steel

BZ - Textured Bronze

TW - Textured White

RAL Colors or

Custom Match -

Consult Factory

OPTIONS

F - Fused (120V / 277V Only)

MSE - Watt-Stopper FS505 External Motion

Sensor (Will Add 1 11/16” to Fixture Depth)

MSI - Steinel HFLUM2-WR Internal Motion

Sensor (120V / 277V Only)

MSI is For Use With The Following:

- All 2 Lamp Wattages

EB - Integral Emergency Battery**

(For Use With MS2B Only)

(Consult Factory For

Application Specs / Battery Option)

TP - Tamper Resistant Screws

W2L - Wire 2 Lamps to Integral

Emergency Battery

(T8 Lamping Only)

MSP - Program Start Ballast

(Standard w/ Motion Sensor) ***

R E P L A C E M E N T PA R T S PA R T N O . N O T E S

24” Clear Acrylic Diffuser

36” Clear Acrylic Diffuser

48” Clear Acrylic Diffuser

30909

30907

30904

**Emergency Battery Options

Initial light output in Emergency mode will last for a minimum of 90 minutes. 1 lamp wired

unless ordered otherwise. The following are suitable for indoor and damp locations. Please

refer to Bodine’s specification sheet

EBW: Bodine’s B50 (Electronic) - Temperature Rating (Ambient) 32° F - 131° F

EBR: Bodine’s B30 (T8 Electronic) - Temperature Rating (Ambient) 41° F - 122° F

We reserve the right to revise the design or components of any product due to parts

availability or change in UL standards, without assuming any obligation or liability to modify any

products previously manufactured, and without notice.

*** For Electronic Wattage Fixtures Being Used in Conjunction With an Occupancy Sensor

(Either Provided by us, or Your Own System), a Program Start Ballast is Recommended in

Order to Maximize Lamp Life.

33 Donald Drive Fairfield, OH 45014 ph:(513)858-6004 fax:(513)858-6038 email:sales@teronlight.com web:teronlight.com

ARCHITECTURAL VANITY

MUIRFIELD

MSE

Project:

Type:

Ordering # :

Comments:

DIMMING APPLICATIONS & RESTRICTIONS

• Step-Dimming is available at 10% and 40% for 25W and 32W T8 linear lamps

- Emergency Battery is not available for use with the 10% and 40% Step-Dim option

- Ballast used is the Robertson brand #PSL232T8MV3D

• Step-Dimming is available at 50% for 17W, 25W, and 32W T8 Linear Lamps

- Emergency Battery is available for use with the 50% Step-Dim option

- Ballast used is the Universal brand #B232PUS50-A

• Step-Dimming is available at 50% for 28W T5 Linear Lamps

- Ballast used is the Philips Advance brand #IOP-2S28-95-SC-SD

- Emergency Battery is available for use with the 50% Step-Dim option

• All 3 ballasts meet California’s Title 24 requirement by reducing power by 50% or more

MOTION SENSOR WITH 2 BALLASTS “MS2B” APPLICATIONS & RESTRICTIONS

• The “MS2B” option is intended to have one lamp providing 100% constant light output, while the other lamp is connected to the

Motion Sensor. Two ballasts are required with this option

• Emergency Battery is available in conjuction with the “MS2B” option for 38” and 50” fixtures

• Emergency battery is not available for 26” fixtures in conjunction with the “MS2B” option due to fixture space restrictions

R E P L A C E M E N T PA R T S

24” Clear Acrylic Diffuser

36” Clear Acrylic Diffuser

48” Clear Acrylic Diffuser

PA R T N O .

30909

30907

30904

We reserve the right to revise the design or components of any product due to

parts availability or change in UL standards, without assuming any obligation

or liability to modify any products previously manufactured, and without notice.

N O T E S

Emergency Battery Options

Initial light output in Emergency mode will last for a minimum of 90 minutes.

1 lamp wired unless ordered otherwise. The following are suitable for indoor

and damp locations. Please refer to Bodine’s specification sheet

EB:

Bodine’s B50 (Electronic) - Temperature Rating (Ambient) 32° F - 131° F

Bodine’s LP550 (T5 Electronic) - Temperature Rating (Ambient) 32° F - 122°F

33 Donald Drive Fairfield, OH 45014 ph:(513)858-6004 fax:(513)858-6038 email:sales@teronlight.com web:teronlight.com

HFLUM2-WR

Fixture Integrated Sensor Module

Project Name:

Location:

HF LUM2-WR Specifications

Item No. 65122

Voltage 120/230/277 VAC, 50/60 Hz

Load Rating 0-800 watts @ 120 VAC, 50/60 Hz incandescent, magnetic or electronic ballasts - 1/4 HP

0-1200 watts @ 230/277 VAC, 50/60 Hz magnetic or electronic ballasts

0-650 watts @ 120/230/277 VAC, 50/60 Hz LED

Transmitter Power 1 mW

Power Consumption < 0.5 W

Time Delay Setting 30 seconds to 30 minutes

Light Level Setting 0.2-200 footcandles

2-2000 lux

HF System 5.8 GHz

Coverage 360° adjustable 3.3 to 26 ft reach (1 to 8 m)

Environment requires enclosure temperature -4° F - 185° F, -20° C - 85° C

Dimensions

(LxWxD)

4.2 x 1.7 x 1.8 in

107 x 42 x 44.5 mm

Warranty 5 years

Certifications C-UL-US Listed, RoHS Compliant,

Contains: FCC ID - W8J-SIR13, IC - 8529A-SIR13

The HFLUM2-WR is a line voltage occupancy sensor module that installs in a fixture, adding energy saving lighting control in each fixture location.

The HFLUM2-WR uses STEINEL’s High Frequency (HF) technology to turn lights on and off based on occupancy.

It works by emitting high frequency electromagnetic waves

(5.8 GHz) into the controlled area. Movement in the area causes a change in the waves’ echo, resulting in occupancy detection. The sensor can detect motion through many materials including glass and the lens of a fixture, enabling the sensor to be hidden from view.

Applications

Mounted in either a ceiling or wall lighting fixture, the sensor module is suited to a wide variety of interior spaces including offices, conference rooms and damp or wet locations when mounted inside sealed and gasketed fluorescent IP65 type fixtures.

Key Features:

• 360° coverage; reach is adjustable from 3.3 to 26 ft

• High frequency technology emits 5.8 GHz electromagnetic waves

• Built-in surge protection with auto-reset

• Lamp seasoning feature provides a simple and convenient 4 day burn in as recommended by lamp manufacturers

• Adjustable time delay and light level settings

• Light level feature allows lighting to remain off during daylight, regardless of occupancy (hold off)

• Wiring is streamlined with three terminals

Line Voltage High Frequency Technology 360˚ of Coverage Fixture Integrated 0.2 - 200 fc www.steinel.net

360° High Bay Occupancy Sensor

HF LUM2-WR

Fixture Integrated Sensor Module

Controls

Sensitivity

Time delay

Light Level

Coverage

Typical mounting height is 8 to 10 ft

Photocell

Sensor dome antenna

Wire terminations

Mounting tabs

Mounting

3.3 - 26 ft

1 - 8 m

Coverage Adjustments Wiring

107 mm

4.2”

97 mm

3.8”

3.3 - 16.4 ft ca. 1 - 5 m

Mounting screw holes are 3.8 inches

(97 mm) apart

Sensitivity:

Adjusts coverage reach from approximately 3.3 feet to 26 feet

Time delay:

30 seconds to

30 minutes

Light level:

.2 (night) to 200

(day) footcandles

NEUTRAL

HOT

LOAD www.steinel.net (800) 852-4343 9051 Lyndale Avenue South, Bloomington, MN 55420 M-04105-1