Catalog Notes Type FEATURES & SPECIFICATIONS INTENDED USE — To be powered by 6, 12 or 24 volt battery equipment as part of an emergency lighting system providing light for the path of egress. CDS fixture matches the appearance of the Quantum® family units. CONSTRUCTION — Single or twin heads available. Fully adjustable lamp heads meet all aiming requirements. Strong, compact and corrosion-resistant with a UL94V-0 flame rating. Constructed of engineering-grade thermoplastic. Lamp housing snaps off for easy lamp replacement. Unit Accessories ELA CDS INSTALLATION — Universal mounting plate for use with single or twin-head applications. Standard mounting plate: 3-1/8" W x 5" H. Mounts to a singlegang switch box. LAMP — Complete range of lamp wattages and voltages available. DIMENSIONS — Single: 3-7/8"W x 4-1/4"H. Twin: 10-5/8"W x 4-1/4"H. Remote Fixture LISTING — Listed in accordance with UL 1598 and CSA C22.2 No.250. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELA CDS N0806 ELA CDS Family Housing color ELA (blank) Ivory white Number of heads Lamp type (composite lamps) Fixture CDS Compact designer square (blank) Single T Twin N0606 6W/6V incandescent N0806 8W/6V incandescent N0912 9W/12V incandescent N1212 12W/12V incandescent Options H0606 6W/6V halogen H0806 8W/6V halogen (blank) Standard mounting plate H0812 8W/12V halogen H1212 12W/12V halogen Unit Accessories FEATURES & SPECIFICATIONS INTENDED USE — To be powered by 6, 12 or 24 volt battery equipment as part of an emergency lighting system providing light for the path of egress. SSB fixture matches the appearance of the Quantum® family units. CONSTRUCTION — Single or twin heads available. Fully adjustable lamp heads meet all aiming requirements. Strong, compact and corrosion-resistant with a UL94V-0 flame rating. Constructed of engineering-grade thermoplastic. Lamp housing snaps off for easy lamp replacement. INSTALLATION — Universal mounting plate for use with single or twin-head applications. Mounting plate: 3-1/8" W x 5" D. Mounts to a single-gang switch box. ELA SSB Remote Fixture LAMP — Glass sealed-beam PAR36 lamp(s). DIMENSIONS — Single: 4-3/4" W x 5" D. Twin: 10-1/2"W x 5"H. LISTING — Listed in accordance with UL 1598 and CSA C22.2 No.250. ORDERING INFORMATION Lead times will vary depending on options selcted. Consult with your sales representative. Example: ELA SSB N0806 SSB ELA Family Housing color ELA (blank) Ivory white TN Desert tan Emergency Number of heads (blank) Single T Twin Fixture SSB Square PAR36 sealed-beam Lamp type (PAR36 sealed-beam) N0806 N1206 N1212 N1812 N2512 N3512 8W/6V incandescent 12W/6V incandescent 12W/12V incandescent 18W/12V incandescent 25W/12V incandescent 35W/12V incandescent H0606 H0806 H1206 H0812 H1212 H3512 Sheet #: UE-406 6W/6V halogen 8W/6V halogen 12W/6V halogen 8W/12V halogen 12W/12V halogen 35W/12V halogen RAUE-100 Catalog Number Notes FEATURES & SPECIFICATIONS Type INTENDED USE — To be powered by 6 or 12 volt battery equipment as part of an emergency lighting system providing light for the path of egress. This remote fixture matches the ELU family appearance. CONSTRUCTION — Single or twin heads available. Unit Accessories ELA Fully adjustable lamp heads meet all aiming requirements. Lamp head and mounting plate constructed of lightweight thermoplastic. Removable bezel and slip-on lamp terminals simplify maintenance and lamp replacement. Strong, compact and corrosion-resistant with a UL94V-0 flame rating. Remote Fixture INSTALLATION — Universal mounting plate for use with single or twin-head applications. Mounting plate: 5"H x 3-1/8"W. Mounts to single-gang switch box. LAMP — Glass sealed-beam PAR36 lamp(s). DIMENSIONS — Single: 4-3/4"W x 6-5/8"H. Twin: 13"W x 6-3/8"H. LISTING — Listed in accordance with UL 1598 and CSA C22.2 No. 250. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELA N0806 ELA Family Housing color ELA (blank) Desert tan W Ivory white B Black ITN Instrument tan Number of heads (blank) Single Fixture (blank) Standard PAR36 sealed-beam T Twin Lamp type (PAR36 sealed-beam) N0806 8W/6V incandescent N1206 12W/6V incandescent N1212 12W/12V incandescent N1812 18W/12V incandescent N2512 25W/12V incandescent H0606 6W/6V halogen H0806 8W/6V halogen H1206 12W/6V halogen H0812 8W/12V halogen H1212 12W/12V halogen Unit Accessories FEATURES & SPECIFICATIONS INTENDED USE To be powered by 6 or 12 volt battery equipment as part of an emergency lighting system providing light for the path of egress. This remote fixture matches applications using the ELSQ series. CONSTRUCTION Matte white polycarbonate frame and black thermoplastic housing are impactresistant and lightweight. ELA SQ Square Fixture Durable and corrosion-resistant with a UL94V-0 flame rating. Prismatic acrylic lens. Tungsten halogen lamp. Surface mounting. DIMENSIONS Single: 10-5/16"W x 10-5/16"L x 3-7/16"H. ORDERING INFORMATION Catalog Number ELA SQR6V ELA SQR12V Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA SQR6V Lamp Volts Watts No. 6 12 10 12 787 783 NOTE: For semi-recessed or fully recessed mounting, order additional kit ELA SRK or ELA FRK, respectively. Lithonia Lighting Sheet #: UE-406 © 1997 Acuity Brands Lighting, Inc., Rev. 12/17/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com