GE Digital Energy Surge Protection for AC Rotating Machines Capacitors, TRANQUELL™ Arresters and Motor Surge Equipment Product Selection & Application Guide GE Surge Protection Capacitors & Equipment Protective capacitors offer surge protection for AC generators, synchronous condensers and large motors. Surge capacitors protect the winding insulation by reducing the steepness of wave fronts applied to or reflected within the machine windings. Dielektrol™ is the GE non-PCB power capacitor dielectric fluid developed to provide an environmentally acceptable product with superior performance and reliability. GE protective capacitors contain an all film dielectric system and hermetically sealed bushings, which permit mounting these capacitors upright or on their side. GE TRANQUELL Arresters when utilized with GE Surge capacitors provide additional security for AC rotating machines. Arresters provide a reduction of lightening stresses by limiting the amplitude of applied impulse waves or reflections within the machine windings. GE provides the complete assembly solution suitable for indoor or outdoor applications. GE can also provide individual capacitor(s) and arresters for individual application requirements. 18L Series Protective Capacitors 38F Series Motor Surge Protection g Application and Selection Guide Surge Capacitors & Motor Surge Protection Table of Contents Introduction-Protective Capacitors...................................................................................3 Product Table-Protective Capacitors................................................................................3 Altitude De-Rating-Protective Capacitors......................................................................4 Guide for Superseded Part Numbers-Protective Capacitors.................................4 Application Guide-Protective Capacitors........................................................................5 Motor Surge Protection Product Selection Process....................................................5 Product Drawings.....................................................................................................................6 2 GEDigitalEnergy.com Application and Selection Guide Surge Capacitors & Motor Surge Protection Introduction – Protective Capacitors Dielektrol Non-PCB Protective Capacitors with Internal Discharge Resistors Indoor or Outdoor Application Product Description, Features & Benefits • Surge protection for AC generators, synchronous condensers and large motors • Time proven GE dielectric system Note 1: Upside down mounting is allowed for 18L0060WH, 18L0061WH and 18L0062WH only. See product table for rating details. • Dielektrol Non-PCB insulating fluid • Provides turn-to-turn insulation protection by reducing steepness of wave fronts applied to or reflected within the machine Note 2: See Altitude de-rating table for de-rating of application voltage. • Used in combination with TRANQUELL GE station arresters for optimum protection • Protective capacitors contain a film dielectric and hermetically sealed bushings, which permit mounting of the capacitors in an upright position or on their side1 • Altitude 0 to 150002 Product Table Voltage Rating rms Volts L-L * Maximum Voltage rms Volts L-L Catalog number Poles per Unit Microfarads per Pole 0 - 650 715 9L18BBB301 3 2400 2640 18L0015WH 4160 4576 6900 Approximate net weight Drawing lbs kg 1.0 4 18 A 3 0.5 36 16.5 4 18L0015WH 3 0.5 36 16.5 4 7590 18L0019WH 1 0.5 29 13 1 7200 7960 18L0065WH 3 0.5 35 16 5 13800 15180 18L0009WH 1 0.25 33 15 2 13800 15180 18L0012WH 3 0.25 66 30 6 24000 26400 18L0010WH 1 0.125 57 26 3 24940 - 18L0070WH 1 0.25 75 34 10 750 * - 18L0004WH 1 4.0 12 5.5 9 3900 * - 18L0005WH 1 4.0 46 20.9 8 13800 15180 18L0051WH 1 0.05 49 22.3 11 13800 15180 18L0060WH 1 0.25 32 14.5 6 6900 7590 18L0061WH 1 0.5 30 13.6 1 4160 4576 18L0062WH 3 0.5 36 16.4 4 1 1 1 18L0004WH and 18L0005WH are rated for DC Applications Units are rated for inverted mounting 2 For other mounting arrangements contact factory 3 2400 and 4160 volt rated designs are identical and use the same catalog number 4 All AC capacitor units are CSA labeled * 1 GEDigitalEnergy.com 3 Application and Selection Guide Surge Capacitors & Motor Surge Protection Altitude De-Rating – Protective Capacitor Altitude De-Rating of Capacitors Above 3,300 ft (1,000 m) Altitude 1 Altitude Correction (1) (ft) (m) 3,300 1000 1.00 4,000 1200 0.98 5,000 1500 0.95 6,000 1800 0.92 7,000 2100 0.89 8,000 2400 0.86 9,000 2700 0.83 10,000 3000 0.80 12,000 3600 0.75 14,000 4200 0.70 15,000 4500 0.67 Multiplier X rated voltage for reduced application voltage at the given altitude Guide for Superseded Models Old Part Number Current Part Number Capacitor Number Voltage of Poles Rating Old Part Number Current Part Number Capacitor Number Voltage of Poles Rating Old Part Number Current Part Number Capacitor Number Voltage of Poles Rating 18F107 18L0015WH 4160 3 18L15WH 18L0015WH 2400 3 9L18BCG301 18L0015WH 4160 3 18F107G3 18L0019WH 4160 1 18L19RH 18L0019WH 6900 1 9L18BCG302 18L0065WH 7200 3 18F26 18L0019WH 2400 1 18L19UH 18L0019WH 6900 1 9L18BCJ101 18L0019WH 6900 1 18F26G2 18L0019WH 2400 1 18L19WH 18L0019WH 6900 1 9L18BCL101 18L0009WH 13800 1 18F27 Discontinued 2400 2 18L65UH 18L0065WH 7200 3 9L18BCM101 18L0010WH 24000 1 18F270G2 18L0010WH 24000 1 18L65WH 18L0065WH 7200 3 9L18CCE301 18L0015WH 2400 3 18F27G2 Discontinued 2400 2 18L6RH2 18L0015WH 2400 3 9L18CCG301 18L0015WH 4160 3 18F28 18L0015WH 2400 3 18L9RH 18L0009WH 13800 1 9L18CCG302 18L0065WH 7200 3 18F29 18L0019WH 4800 1 18L9UH 18L0009WH 13800 1 9L18CCJ101 18L0019WH 6900 1 18F29G2 18L0019WH 4800 1 18L9WH 18L0009WH 13800 1 9L18CCJ301 18L0015WH 6900 3 18F30 18L0019WH 6900 1 9CL1B20 18L0015WH 2400 3 9L18CCL101 18L0009WH 13800 1 18F30G2 18L0019WH 6900 1 9CL1B22 18L0019WH 4800 1 9L18CCM101 18L0010WH 24000 1 18F35 Discontinued 11500 1 9CL1B23 18L0019WH 6900 1 9L18DCE301 18L0015WH 2400 3 18F35G2 Discontinued 11500 1 9CL1B24 Discontinued 11500 1 9L18DCG301 18L0015WH 4160 3 18F451 18L0009WH 13800 1 9CL1B25 18L0009WH 13800 1 9L18DCG302 18L0065WH 7200 3 18F451G5 18L0009WH 13800 1 9L18ACE101 18L0019WH 2400 1 9L18DCJ101 18L0019WH 6900 1 18F467 18L0010WH 24000 1 9L18ACE201 Discontinued 2400 2 9L18DCL101 18L0009WH 13800 1 18F58 18L0015WH 4160 3 9L18ACE301 18L0015WH 2400 3 9L18DCM101 18L0010WH 24000 1 18F585 18L0015WH 2400 3 9L18ACG101 18L0019WH 4160 1 9L18DCM102 18L0010WH 24000 1 18F586 18L0015WH 4160 3 9L18ACG301 18L0015WH 4160 3 9L18ECE301 18L0015WH 2400 3 18F59 18L0009WH 13800 1 9L18ACH101 18L0019WH 4800 1 9L18ECG301 18L0015WH 4160 3 18L10RH 18L0010WH 24000 1 9L18ACH301 Discontinued 4800 3 9L18ECG302 18L0065WH 7200 3 18L10WH 18L0010WH 24000 1 9L18ACJ101 18L0019WH 6900 1 9L18ECJ101 18L0019WH 6900 1 18L15RH2 18L0015WH 4160 3 9L18ACK101 Discontinued 11500 1 9L18FCG301 18L0015WH 4160 3 18L15RJ2 18L0065WH 7200 3 9L18ACL101 18L0009WH 13800 1 9L18FCG302 18L0065WH 7200 3 18L15UJ 18L0015WH 4160 3 9L18ACM101 18L0010WH 24000 1 18L15WH 18L0015WH 4160 3 9L18BCE301 2400 3 9LA6A29 9LA6B1 Discontinued 300 18L0010WH 24000 4 18L0015WH GEDigitalEnergy.com 1 Application and Selection Guide Surge Capacitors & Motor Surge Protection Application Guide – Protective Capacitors Application Information Figure 1 GE Dielektrol Surge Capacitors and TRANQUELL Motor Surge Protectors can be applied directly at the motor or generator terminals to reduce the potential for damage caused by lightning and or switching surges. GE Surge Protective Capacitors reduce the steepness of wave fronts to protect turn to turn insulation from surges applied to or reflected within machine windings. GE TRANQUELL Motor Surge Protectors utilize GE TRANQUELL Surge Arresters applied in parallel with GE Dielektrol Surge Capacitors. When applied together, the arresters protect the major insulation to ground by limiting the amplitude of applied impulse waves or reflections within the machine windings, while the protective capacitor(s) reduce the steepness of the wave fronts. Studies indicate that this dual protection approach results in significant reduction of lightning stresses imposed on rotating machines and contribute to increased security against failures and downtime costs. The enclosures are suitable for indoor and outdoor applications. (See Figure 1). TRANQUELL Motor Surge Protection Product Selection Process 1. Determine the nominal system voltage and connection at the equipment being protected (Line-to Line, delta or wye, grounded or ungrounded). 2. Select product from the Selection Table (catalog number from columns 2 or 3, based upon line-to-line voltage in column 1). 1 Voltage Rating rms Volts (L-L) Catalog Number for Delta & Ungrounded Neutral Systems Catalog Number for Grounded Neutral Systems Arrester Rating kV rms Arrester MCOV kV rms Capacitor Microfarads per Pole µF Dimension "D" (side view in inches)1 Weight in lbs. 2400 38F2401 — 3 2.55 0.5 23 300 4160 38F2402 — 6 5.1 0.5 23 300 — — 38F2403 3 2.55 0.5 23 300 4800 38F2404 — 6 5.1 0.5 23 300 6900 38F2405 — 9 7.65 0.5 23 300 7200 38F2406 — 9 7.65 0.5 23 300 13200 38F2407 — 18 15.3 0.25 23 300 — — 38F2408 10 8.4 0.25 23 300 13800 38F2409 — 18 15.3 0.25 23 300 — — 38F2410 12 10.2 0.25 23 300 24000 38F2411 — 27 22 0.125 36 350 — — 38F2412 21 17 0.125 36 350 See drawing 7 for detail GEDigitalEnergy.com 5 Application and Selection Guide Surge Capacitors & Motor Surge Protection Product Drawings Drawing 2: Single-Pole, 6,900 volts 16.58[421](A) 13.50[343](B) 15.62 [397] (A) 15.62[397](B) 13.50[343](B) 13.50 [343] (B) (2).50x.75 [13x19] SLOTS CL 2.75 [70] (A) 16.58 [421] (A) 16.58[421](B) (2).50x.62 [13x16] SLOTS 15.62[396.7](A) Single-Pole, 24,000 volts 4.62 +.5/-.1 [118] +13/-2.5 CL CL 2.75 [70](A) 4.50 [114](A) 9.00[229](B) CL CL 2.75 [70] (A) 4.62 [117](B)* 4.50 [114](A) 9.00[229](B) .50-13 THD. 1.50 [38] (A) 1.50[38](A) .50-13THD 13.50[343](B) 15.62[396.7[(A) 16.58[421](A) UNPAINTED AREA UNDER BOTH BRKTS FOR GROUNDING 2.75 [70] (A) 3.50 NP .75[19] .50-13 THD 1.25 [32](B) (2).50x.62 [12.7x15.7] SLOTS 15.62[396.7[(A) 16.58[421](A) UNPAINTED AREA UNDER BOTH BRKTS FOR GROUNDING Drawing 7: 38F series GEDigitalEnergy.com 2.75 [70] (A) 3.25 [83] 12.25 [311] (A) TO BOTTOM OF CONDUCTOR 25.06[637](D) TO BOTTOM OF CONDUCTOR 3.25 [83] DIA. 1.00 [25] (B) 8.20[208] (E) 1.50 [38] (A) 3.25 [83] DIA. 15.50[394](B) NP 1.62[41] 23.84[606] (C) 1.25 [32](B) 1.50 [38] (A) 16.40[417](E) .50-13 THD SOLDERLESS CONN. FOR #10 SOLID TO #2 STRD.COND. 8.20[208](E) 11.00[279](B) 6.75[171](B) NP .75[19] .50-13 THD 1.00 [25] (B) 20.56[522](D) 3.25 [83] DIA. 1.62[41] 9.50[241] TYP 16.40[417](E) .50-13 THD SOLDERLESS CONN. FOR #10 SOLID TO #2 STRD.COND. 19.34[491] (C) 1.50 [38] (A) CL 9.50[241] TYP 8.20[208] (E) (2).50x.62 [12.7x15.7] SLOTS 6 22.80 [579] (D) 4.62 [117] (B) 4.62 [117] (B) CL CL 16.40[417](E) TO BOTTOM OF CONDUCTOR 16.31[414](D) 13.50[343](B) CL 9.50[241] TYP 15.09[383] (C) Three-Poles, 13,800 volts 13.50[343](B) CL .50-13 THD UNPAINTED AREA UNDER BOTH BRACKETS FOR GROUNDING Drawing 6: Three-Poles, 7,200 volts CL 1.75 [44] (A) 1.25 [32] (B) UNPAINTED AREA UNDER BOTH BRKTS FOR GROUNDING Drawing 5: Three-Poles, 2,400 & 4,160 volts 21.50 [546] (C) TO BOTTOM OF CONDUCTOR 1.72[44](A) UNPAINTED AREA UNDER BOTH BRKTS FOR GROUNDING Drawing 4: .50-13THD SOLDERLESS CONN FOR #10 SOLID TO #2 STRD COND .50-13 THD. 8.25[210](B) 17.57[446](D) 16.27[413](C) TO BOTTOM OF CONDUCTOR TO BOTTOM OF CONDUCTOR 1.72 [43.7](A) 7.50[191](A) 16.82[427](D) 15.52 [394](C) 1.25 [32] (B) 3.25 [83] (B) 9.00 [229] (B) 4.50 [114] (A) SOLDERLESS CONN. FOR #10 SOLID TO #2 STRD COND. SOLDERLESS CONN. FOR #10 SOLID TO #2 STRD COND. 1.50[38](A) 5.12 [130] (E) CL 12.25 [311] (C) (2).50x.62 [13x16] SLOTS Drawing 3: Single-Pole, 13,800 volts 4.62 [117] (B) Drawing 1: SOLDERLESS CONN. FOR #10 SOLID TO #2 STRD.COND. 1.62[41] NP .75[19] .50-13 THD 1.00 [25] (B) 1.25 [32](B) NP (2).50x.62 [12.7x15.7] SLOTS 15.62[396.7[(A) 16.58[421](A) UNPAINTED AREA UNDER BOTH BRKTS FOR GROUNDING 2.75 [70] (A) Application and Selection Guide Surge Capacitors & Motor Surge Protection Product Drawings Drawing 9: Drawing 10: 750 volts DC Single-Pole, 24,940 volts 16.58[421](A) 15.62[396.7](A) 3.00 [76](A) 1.86 [47] (A) 4.50 [114](A) 9.00[229](B) .50-13 THD. 2.75 [70](E) .281R CL 4.00 [102] (A) CL 0.56 [14](E) 0.75 [19](E) SEE VIEW -A 1.38[35](E) CL 4.12 REF. UNPAINTED AREA UNDER BOTH BRKTS FOR GROUNDING Drawing 11: 101N108 NP 101N107 SIDE OF CASE OPPOSITE MOUNTING BRACKET VIEW -A SOLDERLESS CONN. FOR #10 SOLID TO #2 STRD COND. TO BOTTOM OF CONDUCTOR TO BOTTOM OF CONDUCTOR 12.50[318](A) 21.82 [555] (D) 1.50[38](A) .50-13THD 1.66 [42] (A) NP 20.52 [521](C) 4.50 [114](A) 9.00[229](B) 0.50 [13](A) 3.50 6.12 +.50/-.12 [155] +13/-2.5 CL 4.25[108](A) 5.00 [127] (A) 1.25 [32] (B) 2.75 [70] (A) SOLDERLESS CONNECTION FOR #10 AWG SOLID - #2 AWG STRANDED CONDUCTOR 1.50[38](A) 3.25 [83] (B) CL 4.12 [105] (A) NP267280 SOLDERLESS CONN. FOR #10 SOLID TO #2 STRD COND. .50-13THD CL 13.50[343](B) 1.25 [32] (B) 3.78 [96] (B) 3.50 (D) [89] NP267192A 101N117J 15.62[396.7](A) 17.50[444.5](A) 4.38 +.5/-.1 [111] +13/-2.5 CL 8.25[210](B) NP CL 2.75 [70] (A) 16.58[421](A) (2).50x.62 [13x16] SLOTS 14.12[359](C) 2.94 [75](A) 13.50[343](B) NP (2).50x.62 [13x16] SLOTS 28.05[705](D) 3,900 volts DC 26.75 [671.5](C) Drawing 8: 1.72 [43.7](A) FAR SIDE 101N117J 101N107 (2) .75 X 1.50 SLOTS [19 X 38] 101N108 101N171 UNPAINTED AREA UNDER BOTH BRKTS FOR GROUNDING Drawing A: Single-Pole, 13,800 volts Three-Pole, 0-650 volts 16.58 [421] (A) 15.62 [397] (A) 13.50 [343] (B) (2).50x.75 [13x19] SLOTS CL 2.75 [70] (A) 6.38 [162] (E) CL 9.00 [229] (B) 1.50 [38] (A) • GE 18L surge capacitor terminals are supplied with solderless connectors for #10 solid to #2 stranded conductors. 4.50 [114] (A) 1 .50-13THD C SCHEMATIC DIAGRAM - 103 • Information nameplates are stainless steel also with CSA and non- PCB labels, 101N107 9.75 [248] (C) 101N117L 9.75 [248] (A) 20.30 [516] (D) 19.00 [483] (C) TO BOTTOM OF CONDUCTOR SOLDERLESS CONN FOR #10 SOLID TO #2 STRD COND 1.75 [44] (A) 101N108 101N171 UNPAINTED AREA UNDER BOTH BRACKETS FOR GROUNDING GEDigitalEnergy.com 7 GEDigitalEnergy.com Digital Energy Capacitor & Power Quality Products (518) 746-5750 381 Broadway, Ft Edward, NY 12828 g GE, the GE monogram, TRANQUELL and Dielektrol are trademarks of General Electric Company. Digital Energy reserves the right to make changes to specifications of products described at any time without notice and without obligation to notify any person of such changes. Copyright 2013, General Electric Company GEA-274A (Rev 0) English 140224