CF 25-31-41-51-71 HORIZONTAL WATER BUILT-IN DUCTABLE TERMINAL UNIT Installation and Use Manual M22740C6-04 01/10/07 UNIT IDENTIFICATION ......................................................................... 4 INSTRUCTIONS FOR THE USER .............................................................. 4 GENERAL WARNINGS........................................................................... 5 RESIDUAL RISKS ................................................................................ 6 RECEPTION ....................................................................................... 7 INSPECTION UPON RECEPTION ................................................................................................................................ 7 STORAGE...................................................................................................................................................................... 7 HANDLING..................................................................................................................................................................... 7 POSITIONING ..................................................................................... 8 GENERAL ...................................................................................................................................................................... 8 FUNCTIONAL CLEARANCES ....................................................................................................................................... 8 POSITIONING................................................................................................................................................................ 8 WATER CONNECTIONS ......................................................................... 9 GENERAL ...................................................................................................................................................................... 9 CONDENSATE DISCHARGE CONNECTION ............................................................................................................... 9 AIR CONNECTIONS ............................................................................. 10 FEATURES FOR DUCTS FOR TREATED AIR ........................................................................................................... 10 ELECTRICAL CONNECTION .................................................................. 11 GENERAL .................................................................................................................................................................... 11 STANDARD UNIT ELECTRICAL DATA....................................................................................................................... 11 CONNECTION TO THE MAINS................................................................................................................................... 11 START-UP ........................................................................................ 18 PRELIMINARY CHECKS ............................................................................................................................................. 18 AERAULIC SYSTEM.................................................................................................................................................... 18 WATER SYSTEM......................................................................................................................................................... 18 ELECTRICAL SYSTEM ............................................................................................................................................... 18 VERIFy tensions – absorptions .................................................................................................................................... 19 REMOTE INPUT CONFIGURATIONS......................................................................................................................... 19 SETTING THE SET-POINT ......................................................................................................................................... 19 AIR FLOW CHECK ...................................................................................................................................................... 19 CONTROL ......................................................................................... 20 ROUTINE MAINTENANCE ..................................................................... 30 MAINTENANCE INSPECTIONS .................................................................................................................................. 32 PUT AT REST .............................................................................................................................................................. 32 TROUBLESHOOTING ........................................................................... 33 DECOMMISSIONING OF THE UNIT .......................................................... 34 DISCONNECTING THE UNIT...................................................................................................................................... 34 DISMANTLING AND DISPOSAL ................................................................................................................................. 34 TECHNICAL DATA .............................................................................. 35 DIMENSIONS ..................................................................................... 37 UNIT IDENTIFICATION SERIAL NUMBER LABEL The units are identified by the serial number label shown here. The label lists the type of unit (series and size), serial number, year of manufacture, number of electrical diagram, main technical data, logo and address of the manufacturer. The label is placed on the unit, generally near the electrical panel and also on the external panelling. IT MUST NEVER BE REMOVED. SERIAL NUMBER This provides unique identification of the machine. It makes it possible to trace the specific features of the unit and to identify the components installed in it. Without this number, it is not possible to identify with certainty the spare parts that are specific to that unit. When requesting assistance, always provide the type of machine and the serial number. Write them in the space below so that they are readily available when needed. Type of unit : _________________________________ Serial number : _________________________________ Wiring diagram : __________________________ Year of manufacture : ___________________________ INSTRUCTIONS FOR THE USER • This is a partial sintex of the information provided in the manual; carefully read this manual • Carefully read this manual. Keep it with the electrical diagram. Make it available to technicians for servicing. • Ask the installer for training on start-up, shutdown, changing set points, placing in at-rest status, maintenance, what to do or not to do in the event of a breakdown. • Provide for scheduled maintenance by specialized technicians so as to ensure long-lasting operation of the unit. • If you expect the machine to be shut down for long periods of time, disconnect the electrical power supply. In winter, take necessary measures to deal with possible freezing (unit and system pipes) . COMMON CAUSES OF SHUTDOWN air filter dirty water filter dirty external permissions (remote ON-OFF etc. ) water cut-off valves closed M22740C6-04 01/10/07 page 4 GENERAL WARNINGS MANUAL PURPOSE This manual has been designed to enable the unit to be installed, started up and maintained correctly. MANUAL INSTRUCTIONS It is essential to observe these instructions. The manufacturer declines all liability for any damage that may be caused whether directly or indirectly to persons or things if these instructions are not heeded. MANUAL STORAGE This manual and the unit’s wiring diagram should be carefully stored so that they are readily available to the operator when required. EXPERT PERSONAL The unit must be installed, tested and maintained by expert personal who meet the relevant legal requirements (Italian law No. 46 of 5/3/1990). LOCAL SAFET REGULATION INSTALLATION The installation must be performed observing the local safety regulations. POWER SUPPLY Make sure the power supply conforms to the data on the unit’s rating plate, located inside the door of the main electrical panel. PACKAGING The packaging material (plastic bags, polystyrene foam, nails, etc.) is potentially dangerous and should therefore be kept away from children and recycled in compliance with the local regulations in force. MAINTENANCE Before performing any service operations, cut off the power. Perform the operations in conformity with the local regulations in force. PERIODICAL INSPECTIONS Perform periodical inspections to locate possible loosened or broken parts. If the repairs are not performed, there will be a higher risk for things and peoples to become damaged and injured. FAULT – POOR OPERATION Switch off the unit in the event of faults or poor operation. REPAIR Only have repairs carried out by a service centre authorised by the manufacturer, and insist on the use of original spare parts only. Failure to comply with the above may compromise the safety of the unit. MODIFICATIONS The manufacturer will not accept any responsibility, and the warranty will lapse, in the event of electric and/or M22740C6-04 01/10/07 mechanical modifications. Any modification which is not formally authorized, and which does not respect the instructions given in this manual, will cause the warranty to lapse. INTENDED USE The unit must only be used for the specific purpose it was designed : The unit is designed for civil air-conditioning within the limits defined in the technical bulletin and this manual. Any use other than that specified does not imply any commitment or constraint by the manufacturer in any way whatsoever. ADDITIONAL SAFETY PRECAUTIONS This unit has been especially designed and manufactured so to prevent any risk to persons and health hazard. For this reason, design solutions fit to eliminate (where possible) any cause of risk and sensibly reduce the probability of danger have been adopted. Please refer to the "Residual Risks" section of this manual and strictly observe the behaviour prescriptions listed there in order to prevent any possible risk that hasn’t been possible to avoid in the design stage. DATA UPDATING The manufacturer may be able to modify the data without prior notice as a consequence of constant improvements. REGULATIONS AND CERTIFICATIONS UNI EN ISO 9001 CERTIFICATION Clivet S.p.A., in order to guarantee customer satisfaction, has chosen the ISO 9001 Quality System as the reference for all its business activities. This is demonstrated by the company’s commitment to ongoing improvements in the quality and reliability of its products; its sales, design, purchasing, production and after-sales service activities are the means used to reach such purpose. CE MARK Clivet products bear the CE mark, in compliance with the requirements of the following EC directives, including the latest amendments, and with the corresponding national approximated legislation: • - 98/37/CE • - 89/336/CEE as modified by the directives 92/31/CEE and 93/68/CEE • - 73/23/CEE as modified by the directive 93/68/CEE • - 97/23/CE page 5 RESIDUAL RISKS GENERAL This section lists some of the more common situations which, being beyond the control of the manufacturer, could be a source of risk to persons or property. DANGER AREA The figure below highlights the area in which only authorised personnel may operate. • External danger zone, identified by a precise area around the unit and its vertical projection on the ground in the case of hanging unit. • Internal danger zone, identified by the area that can be entered only after having intentionally removed the protecting panels or parts of these. HANDLING If handling operations are undertaken without adopting all the necessary safety procedures and exercising due care, the unit can fall or topple, causing damage — possibly extremely serious — to persons and/or property, and to the unit itself. Ensure the unit is handled and manoeuvred as directed on the packing and in the present manual, and in accordance with local regulations. In the event of refrigerant gas escaping, refer to the “Safety datasheet” for the particular refrigerant. INSTALLATION Incorrect installation of the unit can result in water leaks, accumulation of condensate, escape of refrigerant, electric shocks, fire, as well as irregular operation or damage to the unit itself. Make certain that the installation is carried out only by a qualified technician, also that the directions contained in this manual are followed and local statutory regulations observed. In the event of the unit being installed in a site where there is even the slightest risk of inflammable gas escapes and consequently the possibility of such gases accumulating in area around the unit, the risk of explosion and fire cannot be discounted. Take every care and precaution when selecting the installation site. Installation on a structure not able to bear the weight and/or afford a secure anchorage of the equipment may cause the unit to fall and/or topple, resulting in damage to persons or property, or to the unit itself. Make certain that every care and precaution is taken when positioning and securing the unit. If the unit is easily accessible to children, unauthorized persons or animals, this is a situation that can give rise accidents and injuries, perhaps serious. Install the unit in a place where access is allowed only to authorized persons, or install barriers or guards preventing unauthorized entry. GENERAL RISKS A smell of burning, smoke or other indications of serious irregularity could signal the onset of situations liable to cause damage to persons or property or to the unit itself. Isolate the unit from the electrical power supply (red-and-yellow) switch. Contact an authorized service centre so that the source of the problem can be identified and remedied. Accidental contact with heat exchange coils, compressors, pressure pipelines or other components can result in wounding or burns, or both. Always wear suitable clothing, including protective gloves, when working in the danger area. M22740C6-04 01/10/07 Maintenance or repairs carried out by unskilled operatives can result in harm or damage to persons and property, or to the unit itself. Always contact an authorized service centre. Failure to close the panels of the unit, or to check that all the fixing screws of the panels are properly tightened, can result in harm or damage to persons or property, or to the unit itself. Verify periodically that all panels are closed and made properly secure. In the event of fire, the temperature of the refrigerant can rise to the point that pressure will exceed safety levels and perhaps cause fluid to be projected. It may also happen that parts of the circuit isolated by closed valves will explode. Do not stand near safety valves, and never leave the valves of the refrigerant circuit closed. ELECTRICAL SYSTEM If the power line connecting the unit to the a.c. supply is incomplete, or if the connection is made with cables of incorrect cross section and/or with insufficiently rated protective devices, this can result in electric shock, toxicity hazard, damage to the unit or fire. All work on the electrical system should be carried out referring to the wiring diagram and to the directions given in this manual, and the system itself must be dedicated. Failure to secure the cover enclosing electrical components can lead to the infiltration of dust and water, ultimately causing electric shocks, damage to the unit, or fire. Always fasten the cover securely to the unit. If live metal parts of the unit are not connected properly to the earth system, they can cause electric shock or even death by electrocution. Make absolutely certain that the connection to the earth system is made in accordance with correct practice. Contact with live parts rendered accessible internally of the unit when the guards are removed can result in electric shock, burns or death by electrocution. Before exposing these parts, make certain the isolating switch on the power line to the unit is set to the OFF position and padlocked, and post a warning sign. Contact with parts that could become live when the unit is started up can result in electric shock, burns or death by electrocution. When there is no need for circuits to be powered up, set the isolating switch on the power line to the OFF position, padlock it and post a warning sign. MOVING PARTS Contact with the fan rotors can cause injury. Before removing the protective grilles or the fans themselves, make certain the isolating switch on the power line to the unit is set to the OFF position and padlocked, and post a warning sign. Before removing the protective grilles or the fans themselves, make certain the isolating switch on the power line to the unit is set to the OFF position and padlocked, and post a warning sign. WATER SYSTEM Defects affecting pipelines, connections or valves and other control componentry can result in water being leaked or sprayed from the system, occasioning damage to property or causing short circuits in the unit. Make certain all hydraulic connections are securely made, following the directions given in the present manual. page 6 RECEPTION INSPECTION UPON RECEPTION Check on arrival that the unit has not suffered damage during transit and that it is complete in every part as specified in the order. In the event of visible damage/deficiencies being discovered, make a note immediately on the delivery document with the comment: CONDITIONAL ACCEPTANCE — CLEAR EVIDENCE OF DEFICIENCIES/DAMAGE DURING TRANSIT Inform both the supplier and the carrier of the details by fax and by registered mail with advice of receipt not later than 8 days after taking consignment. Notifications sent after 8 days have elapsed will be ignored. STORAGE Shelter from: direct sunlight, rain, sand and wind Temperature: maximum 60°C minimum -10°C Maximum humidity: 90% The respect of the instructions on the exterior side of the packaging assures the physical and functional integrity of the unit for the final user’s advantage. It is recommended to: • Handle carefully • Keep in a dry place • Avoid putting other objects on top of the unit (respect the limits of levels of superimposition shown in the package) • Avoid placing the unit with thermoretractable protection under the sun since the pressure of the circuits can assume values which activate the safety valves. HANDLING The operation of handling the unit must be carried out respecting the instructions of the safety norms in force (Legislative Decree 626/94 and following modifications) Before starting the handling operations: • Value the critical points during handling (stairs, flights, disconnected routes, doors, etc) • Verify that the lifting capacity of the means used is adequate to the unit weight • Consider that the barycentre could be moved with respect to the center of the unit • Before starting to lift, verify that the unit is at a stable balance The following examples are indications; the choice of the means and of the handling modes will depend on factors, such as: • The unit weight • Type and overall dimensions of the unit • Place and route for the handling (dirt yard, asphalted square, etc) • Condition of the place of destination (roof, square, etc) • Handling distance characteristics (distances, flights, steps, doors) LABELS / YELLOW BRACKETS SHOW THE LIFTING POINTS DO NOT LEAVE THE PACKAGES LOOSE DO NOT MOVE THE UNITS ALONE FOR SEVERAL UNITS, USE A SUITABLE CONTAINER REMOVING THE PACKING Check for any visible damage. For removing the packaging, use specific personal protection for the operator (gloves, glasses, etc.). Dispose of the packaging by taking it to specialist collection or recycling centres in accordance with local regulations. While removing the packaging, pay attention not to damage the unit. M22740C6-04 01/10/07 page 7 POSITIONING GENERAL For installing air-conditioning systems, it is necessary to consider the following: • the technical spaces necessary for the machine and system • the place where the machine will be installed • the transport of thermal carrier fluids and relevant connections to the unit: o water o air o refrigerant (unit in more sections) • electrical connections If these aspects are not evaluated carefully, they can affect the performances and the working life of the unit. POSITIONING 1. The units are designed for OUTDOOR / INDOOR installations, performed in fixed positions and in areas accessible only to qualified and authorized personnel 2. SAFETY VALVE (only if present on the unit) : the installer is responsible for evaluating the opportunity of installing drain tubes, in conformity with the local regulations in force ( EN 378 ) 3. Install the unit raised from the ground 4. avoid installations in places subject to flooding 5. Verify that the fixing/supporting points are level and suitable to support the weight of the unit (see the weight and the weights distribution) 6. To avoid vibrations is recommended the assembly on specific antivibration mounts 7. In the false ceiling, provide the indicated openings in the functional spaces so as to allow access to the unit for maintenance. 8. Leave free the surface projection of the unit and the functional spaces so as to allow access with ladders or other means. FUNCTIONAL CLEARANCES When placing the unit, please respect the functional clearances indicated in DIMENSIONS section. The functional spaces need to be observed because of the following: • to guarantee the good operation of the unit • to allow the performance of all maintenance operations • to protect the authorized operators and exposed people If more units are placed close to one another, the functional spaces must be doubled. Figure 1 Figure 2 View from above Fan replacement From the panel ( A ) the fan plate can be removed by unscrewing the screws ( E ) that are found around the discharge flange (as shown in the figure above). The drawings below show some assembly sequences. 1) Fix the stay rods to the ceiling 2) Fix the two brackets to the stay rods 3) Fit the block nuts of the brackets 4) Mount the unit onto the brackets and tighten the block nuts Ceiling Stay rods Nut Washer Bracket Antivibration plug Stay rods Grand. A mm B mm 25 1055 305 31 1155 350 41/51/71 1395 350 Washer Block washer Nut Washer Nut Threaded insert Nut M22740C6-04 01/10/07 page 8 WATER CONNECTIONS GENERAL CONNECTIONS SUPPORTS The weight of the hydraulic connections must be supported in the exterior of the unit so as not to stress the connections of user devices (exchangers, coils, humidifiers, etc ) . Piping must be designed with the least possible number of bends and head variations. If the pressure chute of the installation is above the useful prevalence of the pump, the water delivery capacity is reduced as well as, as a consequence, the thermal exchange and the yield. ANTI-VIBRATION DEVICES In case of units with anti-vibration devices, it is necessary to assemble elastic joints, even on water connections. INTERCEPTING VALVES Install on the input and output of the user parts (exchangers, coils, humidifiers, etc) So that it will be possible to carry out all the service operations and possible substitutions without emptying the installation. RISK OF FREEZE If the unit and the relevant water connections are subject to temperatures near 0°C: PRESSURE AND TEMPERATURE INDICATOR Install on the input and output of the user parts (exchangers, coils, humidifiers, etc) So that it will be possible to carry out all the service operations. AUTOMATIC OR MANUAL ESCAPE VALVES Install the highest points of tubes in a way that the air can escape form the circuit. BLEEDING COCK Install them at the lowest points of the circuit, so as to allow emptying. • mix the water of the system with glycol • protect the tubes with heating cables under the tubes insulation • empty the system by verifying that: o no taps are closed so they can not trap the water, even after emptying o there are no low points where the water can stagnate even after emptying; blow if necessary INSTALLATION EMPTYING The refilling of the water present in the installation increase the oxidation phenomena and lime deposits. LEAKAGE TESTS Before performing the insulation of the tubes, carry out a leakage test. If necessary empty only the interested system section and anyway empty or refill the installation if necessary . TUBE INSULATION All tubes of water must be insulated so that to avoid the formation of condensation and thermal dispersions along the tubes themselves. Verify that the insulation is the vapour coil type. The connections for the air escape and for the emptying must be out of the insulating thickness to assure the accessibility. EXPANSION TANK The installation must be kept at the right pressure by both an expansion tank and a combined valve of pressure reduction and discharge; if the components are present on the unit, they must be installed on the installation. The expansion tank must be dimensioned in function of the water in the installation. CONDENSATE DISCHARGE CONNECTION POSITION THE DISCHARGE PIPE SO THAT THE UNIT DISCHARGE CONNECTION IS NOT MECHANICALLY STRESSED. M22740C6-04 Connect the condensate discharge pipe to the discharge tray paying attention not to damage it. Make a trap that, eliminating the depression caused by the fan, stops the return of gas from the discharge pipe (see the figure) Connect the condensate discharge to a rainwater drain. Do NOT use sewerage drains, so as to avoid the return of odours if the water contained in the trap evaporates. Finally, check that the condensate will drain correctly by pouring water into the tray stud. 01/10/07 page 9 AIR CONNECTIONS Proper execution and sizing of air connections are essential for ensuring correct operation of the unit and an acceptable level of silence in the room. When designing and creating ducts, consider PRESSURE DROPS, FLOW RATE and AIR SPEED which need to be compatible with the characteristics of the unit. Special consideration needs to be made for pressure drops that are greater than the unit's static pressure, which would lead to a reduction in flow rate resulting in unit shutdown. the weight of the ducts must not be supported by the connection flanges place anti-vibration joints between the ducts and the unit the connection to the flanges and between the various sections of the ducts must ensure an airtight seal, preventing leakage in delivery and return which would compromise overall system efficiency. for units installed outdoors, the connection to the flanges and between the various duct sections must be watertight limit pressure drops by optimizing the path, the type and number of curves and the branches use curves with a wide radius. Consider whether it might be useful to equip them with deflectors (especially if the air speed is high or if curves are tight) FEATURES FOR DUCTS FOR TREATED AIR 1. The inner surface of the duct must be smooth and washable. It must not contaminate the air. 2. Thermally insulate the ducts and the flanges so as to prevent loss of energy and condensation build-up. 3. Soundproof duct sections that are outside the building in order to keep noise out of the ducts (from the systems, from road traffic, aircraft, etc.) 4. Before entering the building, the ducts must have at least two curves, with a wide radius and equipped with deflectors, to favour noise absorption by the ducts. Proper distribution of air in the room is essential for ensuring comfort levels. In the selection and positioning of grilles, outlets and diffusers, the following are to be avoided: 5. excessive air speed 6. formation of stagnant zones and layering 7. entry of cold air into the room 8. formation of localized currents (due to uneven air distribution) 9. excessive variations in ambient temperature in the vertical and horizontal planes 10. short circuiting of delivery air towards return air For purposes of comfort, the following things need to be considered: 11. air diffusers must be selected by checking the sound power generated at nominal flow rate conditions 12. the disconnections to the diffusers are to be made using flexible elements 13. the return grilles must be amply sized For applications that require a high degree of silence in the system: 14. In delivery and return, provide septum silencers, preferably inserted in sections of ducts located outside the building. The septums must ensure the required dampening with minimum pressure drops (ONLY OUTDOOR UNITS – do not print note). 15. Equip all curves with deflectors. ACCESSORIES The units can be supplied with the following accessories (on demand) : 1) Mixing box 2) Hot water heating coil 3) Electric heating element 4) Spigotted discharge plenum (for sizes 41-51-71, 4 spigots are provided instead of 3) 5) Filter section All these accessories can be used alone or in the various combination desired. They are easily assembled thanks to the predrilled 25mm coupling flanges. The sequence illustrated below is purely indicative. M22740C6-04 01/10/07 page 10 ELECTRICAL CONNECTION the unit; the electrical data shown in the technical chart refer to standard units. In the event of differences between the data of the registration plate and the data shown in this manual, as well as in the technical chart, please refer to the DATA SHOWN IN THE REGISTRATION PLATE. GENERAL The characteristics of the electrical lines and relevant components must be determined by SPECIALIZED PERSONNEL ABLE TO DESIGN ELECTRICAL INSTALLATIONS; moreover, the lines must be in conformity with professional procedures and the regulations in force. The protection device of the unit power supply line should break off the short circuit power whose value should be determined according to the plant features. All electrical operations should be performed by trained PERSONNEL HAVING THE NECESSARY REQUISITES UNDER LAW and being informed about the risks relevant to these activities. The section of supply cables and protection cable must be seized according to the characteristics of the protections used. Before performing any operation on the electrical system, make sure that the unit supply line is SELECTED AT START. SIGNALS / DATA LINES Do not overpass the maximum power allowed, which varies, according to the type of signal. The earth connection must be made prior to other electrical connections. Lay the cables far from power cables or cables having a different tension and that are able to emit electromagnetic disturbances. For all electrical type operations, REFER TO THE ELECTRICAL DIAGRAM ATTACHED TO THE UNIT; the number of the diagram is shown on the registration plate positioned on the electrical board or next to it. Do not lay the cable near devices which can generate electromagnetic interferences. Do not lay the cables parallel to other cables; cable crossings are possible, only if laid at 90°. The electrical diagram should be carefully kept together with this manual and should be AVAILABLE FOR FUTURE INTERVENTION ON THE UNIT. Connect the screen to the ground, only if there are no disturbances LINE OF UNIT POWER SUPPLY The ELECTRICAL DATA OF THE UNIT are shown in the technical chart of this manual and on the unit registration plate. The presence of accessories can vary according to Assure the continuity of the screen during the entire extension of the cable. Observe, if any, the requirements about impendency, capacity, attenuation STANDARD UNIT ELECTRICAL DATA Sizes 25 31 41 F.L.A. FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Total A 2,13 2,74 2,74 F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Total kW 0,47 0,61 0,61 M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A 0,85 0,85 0,85 51 71 4,34 6,48 0,98 1,43 1,41 1,83 Voltage unbalance: max ± 2% with an admitted tolerance: ± 6% CONNECTION TO THE MAINS 1. Make sure that the sectioning device at the beginning of the unit’s power line is opened, locked and equipped with a signal. 2. Open the general line disconnecting switch (if present) 3. Verify that the net is in conformity with the data shown in the registration plate placed on the electrical board. 4. Check the dimensional drawing for the input of the electrical lines 5. Take away the closing plate placed on the electric board (ONLY IF PRESENT) and drill a hole through it to pass the cables through) M22740C6-04 01/10/07 6. Protect the cables, using the fairlead of an adequate size. 7. Using the layout of the electrical diagram, single out the connecting terminals of the electrical supply cables, of the neutral (if foreseen) and the PE protection cable 8. Connect the cables to the relevant terminal boards 9. Before supplying power to the unit, make sure that all the safety devices that were removed during electrical connections are positioned again. page 11 UNIT WITH TERMINAL ONLY The fan speed control is performed on 3 speed. L : low speed M : medium speed H : high speed C : common The unit with terminal only, can be coupled to: HID-E1 3 SPEED SELECTOR 3 speed selection (MIN - MED - MAX) SUMMER / WINTER manual change UNIT WITH 3 RALAY BOARD In this configuration the unit can be coupled to: HID-E1 3 speed selector + ON/OFF For wall installation, it allows: • 3 speed selection (MIN - MED - MAX) • Summer / Winter manual change M22740C6-04 01/10/07 page 12 HID-E2 Semplified ambient control E/I+3V+on/off The wall installation allows: • temperature setting (10-30°C) • 3 speed selection (MIN - MED - MAX) • on/off • Summer/Winter manual change TM : min. temperature thermostat VC : Continuous ventilation VT : Regulated ventilation W : Winter operating S : Summer operating HID-E3 multi-function environment control The wall installation allows the following: • Automatic adjustment of the fan speed (MIN - MED - MAX) • Silent operation (minimum speed of the fan) • On/off • Ambient temperature adjustment with the adjustment knob: the central position of the knob corresponds to the comfort condition (20°C in heating mode, 24°C in cooling mode), temperature can be changed by +/- 5°C from the comfort condition by rotating the knob • Automatic selection of Summer/Winter: the choice between heating and cooling is performed automatically by detecting the temperature of output water to the fan-coil (water temperature less than 17°C = operation in cooling mode, water temperature higher than 21°C = operation in heating mode) • Hot Start function: in heating mode, the fan does not start until the thermal battery is properly hot • Destratification cycle • dirty filter signalization minimum water temperature probe (supplied separately) M22740C6-04 01/10/07 page 13 HID-E4 multi-function environment control 2 or 4 pipe fan coil check for the ambient temperature control by: • 0-10 Vcc proportional outputs • adjustable proportional band • adjustable neutral zone • Selector of the manual seasonal change • Selector of the motor 3 speed Remote or internal temperature probe (optional) In the configuration with 3 relay BOARD, it is possible to pilot more than one unit with only one thermostat. The following diagram is indicative; refer to the wiring diagram enclosed with the unit. HID-E1 / E2 / E3 / E4 V3 V2 V1 V3 V2 V1 UNIT 1 M22740C6-04 UNIT 2 01/10/07 page 14 UNIT WITH TERMINAL SPACE ELECTRONICS (unit with CTS option) + 3 RELAY BOARD + HID-T2, HID-T3 or HID-TI2 THERMOSTAT TERMINAL SPACE electronics 3 RELAY BOARD 485 serial module ( optional ) The TERMINAL SPACE electronics, can be coupled to the room control indicated below. 2 In both cases, the type of the used cabled must be 2x0.35 mm with shield on the. Max. distance: 15m HID-T2 electronic room control 1 2 + 3 gnd 4 5 TEMPERATURE probe management ( HID-T2 ) OR TEMPERATURE + HUMIDITY ( HID-T3 ) 12 + 11 10 -- gnd HID-TI2 built-in electronic room control 9 + 8 7 NET 12 11 10 UNIT THERMOSTAT The recessed room control is supplied with a series of supports that make it possible to adapt it to the main civil series of plates: refer to the instructions provided with the thermostat. M22740C6-04 01/10/07 page 15 ELECTRICAL CONNECTIONS TO BE HANDLED BY THE CLIENT For all connections refer to the electrical diagram supplied with the unit. • REMOTE ON – OFF • Modulating valve H2O (power supply 24V to be provided for by the client). It is possible to control one valve only (2-pipe-systems) or two different valves for heating and cooling (4-pipesystems) • Fresh air Shutter • Room thermostat • RS485 serial line (refer to document RS 485 NETWORK GUIDELINES) • Electrical resistance section If present, the electrical resistances must be enabled by modifying the following parameters: P24 = 3 enables INPUT 2 as resistance thermal alarm P27 = 1 main heating element P53 = 3 signal 0-10V The unit is produced with disabled auxiliary inputs. They can be set as described in the following table; Default modifications can only be performed by the assistance centres. parameter Input P23 IngAux1 P24 IngAux2 P51 IngAux3 Value 0 1 2 0 1 2 3 4 0 1 2 3 4 Meaning No function ON - OFF presence No function HEAT - COOL ECO Resistance alarm flow switch No function HEAT - COOL ECO Resistance alarm flow switch open closed off absent on present cool normal alarm Set by par heat Eco ok Set by par cool normal alarm Set by par heat Eco ok Set by par RS485 SERIAL PORT If Clivet provides only the units with BMS communication port (installed or provided separately), it is responsible only for the units themselves and not for the units downstream. Therefore CLIVET is not responsible for operations such as choice and installation of cables, connection, serial addressing and checks on network functionality. On request, Clivet provides the specifications for the communication protocol of its units and the necessary guidelines to connect them to RS485. The card for RS485 serial line must be connected to the main card using the appropriate wire provided. The network termination jumper alongside the screw terminal board for the connection of 485 must be inserted if the unit is the last one in the network. JUMPER : DISINSERITO - INSERITO M22740C6-04 01/10/07 page 16 Following some indications for the serial connection ; refer anyway to the CLIVET “RS 485 NETWORK - GUIDELINES” and ask for the COMMUNICATION PROTOCOL of the TERMINAL.SPACE electronics. - The total length of each serial line, has not to be more than 1000 metres The potential difference between the “earths” of two RS485 devices must be lower than 7 V - Twisted and shielded couple of conductors Conductor section 0.22mm2…0,35mm2 Nominal capacity among the conductors < 50 pF/m nominal impedance 120 Ω Recommended cable BELDEN 3105 A TYPE OF NETWORK The serial lines must be connected in bus typology, i.e. nodes to more points are not admitted.. OK NO ! Sistema di supervisione SHIELD - It must be connected to a ground with no troubles - Connected to the round in only one point - The shield continuity must be kept constant during all the serial shield extension. POSITIONING OF THE ROOM THERMOSTAT The selection of the place of installation is decisive for room comfort and energy consumption. The thermostat must be positioned: • in a room with average temperature and humidity that are representative of other rooms • at a height of 150 cm • preferably on an internal wall Positions to avoid: • near sources of heat (lamps, computers, etc.) • exposed to direct sunlight • in a position in the direct flow of air from outlets of diffusers • behind curtains of pieces of furniture • near doors and windows to the outside • on walls where there are chimneys or heating pipes • on external walls M22740C6-04 01/10/07 page 17 START-UP ALL THE EQUIPMENT MUST BE COMMISSIONED BY AUTHORISED SERVICE CENTRES. THIS SERVICE IS LIMITED TO START-UP OF THE UNIT ONLY AND NOT THE CONNECTIONS OR INSTALLATION OF THE SYSTEM. ONLY QUALIFIED TECHNICIANS MUST PERFORM THE FOLLOWING OPERATIONS. Perform a seal check at max. working pressure checking that no leaks are present. PRELIMINARY CHECKS Before checking, please verify the following 1. 2. 3. 4. 5. 6. 7. the unit should be installed properly and in conformity with this manual. the electrical power supply line should be sectioned at the beginning. the sectioning device is locked and the proper warning “not to operate” sign is placed on the handle. make sure no tension is present the coils must be clean and free of obstacles the ventilators must be free of leaves, cardboard, fixed obstacles (beams, barriers, etc.), snow, etc the external ventilators must not be blocked The external ventilators can be subject to a temporary block, especially if the inactivity period before the first start-up was quite long or if outside temperature is very low. It is also possible to unblock them manually (ONLY WHEN THE UNIT IS UNPLUGGED – RISK OF INJURES) so that jams or electric overloads are avoided when the unit is restarted. AERAULIC SYSTEM Check that: 1. the air filters are not removed from unit and are cleaned (possible ventilation checks and the operating starting period determinate a ducting “cleaning” with conseguent filter precocius clogging, filters that must be cleaned and replaced) 2. ducting are completed, connected and without obstructions 3. possible dampers are opened (for ex. fire stop dampers) and calibrated (for ex. fresh air damper, control damper, ejection damper) 4. Grilles, outlets, and diffusers must be free of obstructions (furniture, shelves, etc.), open and precalibrated, so as to ensure proper air distribution, which is essential to comfort in the room. WATER SYSTEM Ensure that the plumbing system has been washed. Drain the wash water before connecting the unit to the system. Check that the water circuit has been filled and pressurised. M22740C6-04 01/10/07 Check that the shut-off valves in the circuit are in the "OPEN" position. Check that there is no air in the circuit. If required, bleed it using the vent valves in the system. Check that there are no ARIES EFFECTS in the transient (pump and / or valve activation/deactivation) When using antifreeze solutions, make sure the glycol percentage is suitable for the type of use envisaged. % weight of ethylene glycol Freezing point Safety temperature 10 % 20 % 30 % 40 % - 4 °C - 2 °C - 9 °C - 7 °C - 15 °C - 13 °C - 23 °C - 21 °C Check that the circulator pumps are not blocked. In fact, their motor shaft may seize up, especially after long shutdowns. Unblocking can be accomplished with a screwdriver using the purge hole. ELECTRICAL SYSTEM Check the proper tightening of the screws that fix the conductors to the electrical components in the board (during handling and transportation, the vibrations could have loosened them). Verify that the unit is connected to the ground plant. Control that all panels and protection devices of the unit are repositioned and blocked. Charge the unit by closing the sectioning device, but leave it on OFF. Make sure that the tension and net frequency values are within the limit of: 230 +/- 6% single phase unit; 400/3/50 +/- 6% three-phase unit Control the unbalancing of the phases: it must be lower than 2% . Example: L1 - L2 = 388 V, L2 - L3 = 379 V, L3 - L1 = 377 V average of the measured values = (388 + 379 + 377) / 3 = 381 maximum deviation from the average = 388-381= 7V Unbalancing = (7/381) x 100 = 1.83% = ACCEPTABLE Operating out of the indicated limits causes the loss of the guarantee as well as very serious damages. page 18 VERIFY TENSIONS – ABSORPTIONS Check that the temperatures of the fluids are included in the WORKING LIMITS. If the controls of the previous paragraphs are positive, it is possible to restart the unit. For information on the control panel, refer to the paragraph CONTROL. While the unit is working (ATTENTION ELECTRIC RISK: WORK SAFETLY) check: • • • • Power supply tension Phase unbalance Total absorption of the unit Absorption of the single electric loads Pa B A D 2 C 1 3 L/sec REMOTE INPUT CONFIGURATIONS Check used remote inputs are activated (ON-OFF etc.) as given in the instructions in the ELECTRIC WIRING chapter. SETTING THE SET-POINT Check if it is necessary to modify the set-points shown in the CONTROL chapter AIR FLOW CHECK The effective unit flow-rate is function of the aeraulic system characteristics. It is so necessary to check the air flow-rate and eventually to proceed with the appropriate calibrations on the system (dampers, diffusers etc) and on the unit (fan speed control, pulley calibrations etc in base of the unit type and its configuration). Before performing the check, make sure that M22740C6-04 the system has been completed in all its parts (derivations, dampers, grilles, diffusers etc) . 01/10/07 D = unit head-flow rate curve A = system calculated curve 1 = project theorical working point 3 = if the system has pressure drop lower than the project ones, the working point will be the 3,with flow-rate higher that the project one 2 = if the system has pressure drop higher than the project ones, the working point will be the 2, with flow-rate lower that the project one In the time the working point can change, for example for the operations on the system (grilles covered by furniture, closed outlets to modify the air diffusion, exclusion or addition of the distribution sections etc.) or for lacking maintenance (clogged air filters, blocked dampers etc) . page 19 CONTROL 21.0 CONTROL (FOR UNIT WITH CTS TERMINAL SPACE ELECTRONICS AND HID-T2 , HID-T3 , HID-TI2 THERMOSTAT) REMOTE ECO AUTO g in Sw o Ec LOCAL OR REMOTE MANAGEMENT The unit can be managed locally from the thermostat or remotely through the use of a RS485 serial line with MODBUS protocol. ON The unit can be switching on/off: • by thermostat • by digital input (set by parameter) • by net (set by parameter) OPERATION The unit has 2 set-points: one for heating and one for cooling. The first one is automatically kept lower than the second one with a difference of at least 1°C. The regulation module compares ambient temperature with the set-point and tries to keep it as close as possible to it; therefore, it varies the fan speed, the water capacity or both of them according to the configuration. The unit operating is enabled only if the water temperature: • in WINTER is higher than 30°C • in SUMMER is lower than 20°C OPERATING MODES AUTOMATIC The modules automatically commute in cooling or heating mode. The change occurs according to the input water temperature (2-pipe unit) or return air (4pipe unit. Set the P31 parameter = 1 MANUAL You choose manually if activating cooling mode keys Set the P31 parameter= 0 ECO Economic operation, it prefers saving energy more than comfort in cooling mode the setECO is higher than the standard set in heating mode, it is lower the deviation value is defined by P10 OffsetEco MANUAL FAN Fan speed is set manually; however, the unit regulates the environment temperature according to the AUTO, MANUAL or ECO modes ANTI-TAMPERING LOCK Any attempt to change settings is prevented: the thermostat keys are deactivated. or heating mode using the relevant C H AN G E O F AU T O M AT I C M O D E – 2 - P I P E U N I T In this mode, a neutral zone is foreseen when the unit is positioned in a CHANGE OVER status for a time sufficient to probe water temperature. The status is displayed by a “CO” flashing. After that time, if water temperature is out of limit, the H2O alarm is signalled. Water temperature is detected (therefore, the cooling/heating modes are defined) only if power is demanded. In this operation type, COOLING and HEATING sets are activated simultaneously; when one of the set is bypassed, water temperature is detected and the mode is defined. When thermo-regulator sets are met, the last operation mode is displayed. The set that is the opposite to the actual one is determined internally by the regulator by a constant that is defined ZoneChangeOver: with unit in COOLING: set heating (opposite)= current set – ZonaChangeOver with unit in HEATING: set cooling (opposite) = current set + ZonaChangeOver M22740C6-04 01/10/07 page 20 AUTOMATIC MODE CHANGE CHANGE OVER COOLING ON HEATING ON OFF Temp H2O 1 °C 1 °C P03 P02 VALVE IN THE AUTOMATIC MODE valve 0,3°C 0,3°C Set sod. ON OFF T amb . °C set COOL set HEAT VALVE IN THE AUTOMATIC MODE IN ECO MODE valve ON OffSetEco OffSetEco 0,3°C 0,3° OFF T amb . °C set HEAT set COOL H I D - T 2 o r H I D - T 3 R O O M T H E R M O S T AT visible if unit managed by NET (if present) 21.0 visible with active HUMIDIFICATION/DEHUMIDIFICATION (if present) visible in ECO mode visible with unit in HEATING REMOTE visible with unit in COOLING HID-T2 set-point ECO AUTO in Sw g o Ec visible if the cooling/heating choice is AUTOMATIC switch the thermostat on press and hold the ON OFF key for 4 seconds If the function is managed remotely via ModBus, no modification is possible (the word REMOTE starts flashing) Activate / deativate the ANTI-TAMPERING LOCK Press and hold ECO + SWING keys for 5 seconds The lock is shown by three horizontal bars when any key is pressed. If the function is managed remotely via ModBus, no modification is possible (the word REMOTE starts flashing) M22740C6-04 01/10/07 HID-T + Sw in g 5 sec page 21 Modify the set-point Pressing on the arrows raises or lowers set-point of the actual operation (heating, ECO heat., cooling ECO cool.). The difference between the two set-points can not be less than 1°C and this value is automatically maintained. If, for example, the unit is in cooling mode and the summer set point is decreased up to the winter set value, the winter set value is also decreased. If the function is managed remotely via ModBus, no modification is possible (the word REMOTE starts flashing) Display the ambient temperature Press and hold both arrows of the SET key, and the ambient temperature will be displayed alternated to the “ t a ” writing. HOLD PRESSED Display room humidity ONLY FOR HID-T3 THERMOSTAT WITH UR PROBE Press and hold both arrows of the SET key, and the ambient temperature will be displayed alternating with the letters “ta”.. Press and hold the Set key again to see the humidity value alternating with the letters “ur “. cooling Switch from the HEATING mode to the COOLING mode and vice versa ; heating ) If the unit is in manual mode, the switch is performed by the relevant key (cooling If “AUTO” is displayed, the switch from one mode to another is managed automatically from the unit and, if this key is pressed, no change occurs. If the function is managed remotely via ModBus, no modification is possible (the word REMOTE starts flashing) heating Switch the unit to ECO mode Press the ECO key Repeat the operation to restore the standard operation The ECO summer set point is higher than the SUMMER set point; the ECO winter set point is lower than the WINTER set point. If the function is managed remotely via ModBus, no modification is possible (the word REMOTE starts flashing) Switch the unit to MANUAL VENTILATION AUTOMATIC ventilation: the fan speed is self-adjusted according to ambient temperature MANUAL ventilation: speed is increased or decreased by the user. Pressing one of the two arrow keys, the automatic ventilation is deactivated. In manual ventilation, the bar corresponding to the active speed is flashing. To restore the AUTOMATIC ventilation: Increase to maximum speed Another pressure of the key will make all 8 bars flash If no action is performed, the unit returns to automatic ventilation If the function is managed remotely via ModBus, no modification is possible (the word REMOTE starts flashing) ing Sw Open / close the air supply damper (if present) M22740C6-04 01/10/07 page 22 AL AR M S V I S I B L E B Y T H E D I S P L AY BEFORE RESETTING AN ALARM, IDENTIFY AND ELIMINATE THE CAUSE OF THE STOP; REPEATED RESETS CAN CAUSE IRREVERSIBLE DAMAGE. The ALARMS show a potentially dangerous situation for the unit. Before resetting an alarm, identify and eliminate the cause of the stop; a repeated reset can cause irreversible damage. In the event of doubt, ask for an authorized assistance centre. The table refers to all the variables that are managed by the electronic system. According to the unit configuration and its accessories, few alarms might not be significant. RES FES BT1 BT2 BT3 H2O SLF CO EHH SYS ERR Active resistance alarm Active electrostatic filter alarm Air probe fault alarm Water probe fault alarm Fresh air probe fault alarm Water temperature alarm not fit Active level sensor alarm Mode change in progress (for the automatic mode); is not an alarm Lack of communication/wrong thermostat connection Fault internal to the control module Configuration error P AR AM E T E R S A C C E S S TO P A R A ME TE R S FOR THE STANDARD USE, THE ACCESS TO PARAMETERS IS NOT NECESSARY. THE FOLLOWING OPERATIONS ARE NECESSARY FOR CALIBRATIONS AND CONFIGURATIONS, THEY ARE EXPRESSLY ADDRESSED TO THE AUTHORIZED ASSISTANCE CENTRES OR QUALIFIED TECHNICIANS. Switch on and off the thermostat with the ON-OFF key and wait until the display shows the set-point. ing Sw Within 5 seconds, press the SWING and ON-OFF keys simultaneously until the P01 code appears + in 5 sec use the “UP” and “DOWN” keys to scroll along the parameters The value of the parameter to be modified is displayed with the ECO key Decrease or increase the parameter value The new parameter value is memorized with the ECO key M22740C6-04 01/10/07 ing Sw Simultaneously press the SWING and ON-OFF keys to exit until the set-point appears + page 23 L I S T O F T H E P AR AM E T E R S AC C E S S I B L E B Y T H E T H E R M O S T AT Par Description range UM Def. P01 BandaLavoro: Working band 0 ÷ 15.0 °C 2.0 P02 MaxH2Ocool: Water max. temperature for cooling operating 0 ÷ 30.0 °C 20.0 P03 MinH2OHeat: Water min. temperature for heating operating 0 ÷ 40.0 °C 30.0 P05 TimeOnPeriodical Defines the duration of the ON phase of the periodical 0 ÷ 999 min 2 P06 TimeOffPeriodical Defines the duration of the OFF phase of the periodical 0 ÷ 999 min 5 P10 OffsetEco 0 ÷ 4.0 °C 3.0 P11 SetUrHeat: Heat UR set point 30 ÷ 70 % 50 P12 BandUrHeat: Intervention band of the heat humidifier 0 ÷ 10 % 5 P21 FanOffCool: Fan status at “cooling” thermoregulator, satisfied. 0: stop, 1: continuous , 2: periodical 0…2 num 2 P22 FanOffHeat: Fan status at “heating” thermoregulator, satisfied. 0: stop, 1: continuous , 2: periodical 0…2 num 0 P31 ModoAuto: It enables the automatic saison change 0: Manual, 1: Auto 0…1 flag 0 P41 BT1 probe calibration -9.9 +10.0 °C 0.0 P42 BT2 probe calibration -9.9 +10.0 °C 0.0 P43 Thermostat temp. probe calibration -9.9 +10.0 °C 0.0 P44 Thermostat UR probe calibration -9.9 +10.0 %UR 0.0 S01 TESToperativa °C S02 TH2Ooperativa °C S03 TARIAoperativa °C S04 URoperativa Hr% S05 Actual mode S06 CurrentSetpoint °C S07 Current humidity Set Hr% S08 Errors S09 Active humidifcation flag S10 Active dehumidification flag S11 FanStatus : 0: off, 1: on 0…1 flag S12 Actual fan: 0-7 if motor 0-10 V 0-3 if 3 speed motor 0-1 if single-speed motor 0…7 num M22740C6-04 bitmap bitmap 01/10/07 page 24 H I D - T I 2 R O O M T H E R M O S T AT operating mode selection increase the selected field decrease the selected field OK confirm the set datum / thermostat ON – OFF Ventilation status Management by ELFO CONTROL Active humidification Active compressor Unit in COOLING Enabled ECO Setpoint Unit in HEATING Unit automatically chooses to cool or heat GENERAL DESCRIPTION The room thermostat HID-TI2/TI3 (hereafter HID) is a device for recessed installation for the remote control of the unit to which it is connected. It is therefore not a MODBUS network thermostat. It can be connected to terminal units equipped with terminal.ROOM or terminal.SPACE electronics and makes it possible to set: • desired humidity/temperature • the desired type of ventilation • a series of advanced functions for the unit to which it is connected • display any error codes that correspond to alarms sent by the adjustment unit. • In the HID-TI control there is also a temperature sensor that can be used as a remote sensor for the unit to which it is connected. OPERATING MODES "Normal" operation, HID-TI connected to CLIVET-BUS: • the HID thermostat shows the operating status of the unit to which it is connected • periodically measure the temperature/humidity in the room where it is installed • it is possible to use only the 4 front keys (user programming) • "Nolink" operation, HID-TI not connected to CLIVET-BUS: • the thermostat is powered by auxiliary power (a battery must be present) • it is possible to access hidden keys for installer use • it is a temporary mode that allows "advanced programming" of the unit. INITIAL RESET Insert the battery (auxiliary power supply) and then press the power on key [A] [A]. All display segments will come on for about 3 seconds. Then the display will show the firmware revision of the device. If the HID device is not connected to CLIVETBUS within one minute, it will go off. During this time, you can only use the hidden buttons for use by the installer. You can also use the HID device without a battery. The initial reset is carried out simply upon connection with the CLIVETBUS. After the initial reset, upon connection to the CLIVETBUS, the device goes into normal operating mode. USER PROGRAMMING User programming makes it possible to: • choose the operating mode of the unit (heating, cooling, eco, fan) • set the adjustment set point • manage the fan speed manually or automatically • enable/disable the floating shutter of the air supply (swing) • display ambient temperature • power on/off the adjustment unit • activate/de-activate silenced mode POWER ON/OFF To power on/off the adjustment unit, press and hold the OK key. Off status is indicated on the display by the message OFF. M22740C6-04 01/10/07 page 25 SELECTION OF MODE OF OPERATION If you press for about 3 seconds on the key you can select the desired operating mode in the following cyclical sequence. if you press the key heating il the display will show the symbols that define current operating mode. → Economical heating → cooling → Economical cooling → ventilation when you press the key [OK] you confirm the displayed mode. The symbols will flash during setting of the mode, and then normal operation resumes. During programming of the operating mode, if no key is pressed for about 10 seconds, you will go back to normal operation, without modifying the operating mode. MODIFICATION OF ADJUSTMENT SET POINT In normal operation, for operating modes that include it, you can modify the adjustment set point using the keys [] e [] respectively to increase/decrease in steps of 0.1°. MANAGEMENT OF FAN SPEED VENTILATION MODE in VENTILATION MODE, no adjustments are made to the temperature you can change fan speed using keys and . MODES: HEATING, ECONOMICAL HEATING, COOLING, AND ECONOMICAL COOLING press briefly on the key : the display will show the message “Fan” and the bar of the fans use the keys and select the desired speed go back to normal operation by pressing the key OK During fan speed modification, if no key is pressed for about 10 seconds, normal operation will resume, preserving any modifications that have been made. When setting fan speed, you will go from AUTOMATIC (where the speed of the fans is controlled automatically based on ambient temperature) to MANUAL operation where the user sets the speed. To go back to automatic fan operation, repeatedly press until the entire bar is flashing. MANUAL STATUS OF THE FANS IS INDICATED BY A FLASHING BAR The setting of fan speeds is not cyclical. SILENCED MODE To activate/de-activate silenced mode briefly press the key OK. Silenced mode is indicated on the display by the message SIL. DISPLAY OF AMBIENT TEMPERATURE You can display the ambient temperature as measured by the probe on the thermostat or the one on the unit. From normal operating status: press briefly on key : the display will show the message Fan and the bar of the fans. press key again: the display will show only the message tA. press the key [OK] to confirm the selection: The message tA will flash on the display, followed by a return to normal operation in which the message tA will alternate with the ambient temperature for a few seconds. You can also go back to normal operation by pressing, instead of the key OK the key without pressing any key. or you can wait about 10 seconds SWING MODE - CONTROL OF AIR SUPPLY FLOATING SHUTTER In normal operating status, you can activate/deactivate the Swing function by simultaneously pressing the keys [] and []. There is no indication on the display for the activation/deactivation of this function. M22740C6-04 01/10/07 page 26 BATTERY CHECK Each time it is powered on, and whenever it is disconnected from the CLIVETBUS, the device performs a check of the battery charge, which is the source of auxiliary power. If the battery is nearly dead, the message bAt will appear bAt The instrument also works even without an auxiliary power supply. In this case, only the functions related to the front keypad are accessible. SIGNALLING OF ALARMS AND MALFUNCTIONS Any alarms generated by the terminal unit are displayed by the following codes: RES FES BT1 BT2 BT3 H2O SLF CO EHH SYS ERR EUR Active resistance alarm Active electrostatic filter alarm Air probe fault alarm Water probe fault alarm Fresh air probe fault alarm Water temperature alarm not fit Active level sensor alarm Mode change in progress (for the automatic mode); is not an alarm Lack of communication/wrong thermostat connection Fault internal to the control module Configuration error Fault humidity probe The alarm “EHH” is shown about 30 seconds after communication problems between the device and the adjustment unit. ADVANCED PROGRAMMING Hidden buttons for use by installer: accessible by extracting the thermostat from its housing. 5, 6: not used 7: reset of the fan fonct. hours keys accessible only with a tool R: thermostat reset A: thermostat starting A 8: it hides the dirty filters R 11 10 9 8 7 6 5 9: self-addressing 10: access to the configuration parameters 11: keypad lock/unlock KEYPAD LOCK Used to disable functions related to the pressing of user keys. Take the thermostat out of its housing, and press the key [11]. The display will show the message bLC put thermostat back in place The message bLC will flash until the procedure is complete (a few seconds). From this moment on, pressing any key will not have any effect, and will instead cause the display to momentarily show the message bLC. To go back to a normal situation, release the keypad lock and repeat the operation. bLC For further details on advanced programming see instructions provided with the room thermostat. VENTILATION The system can manage 2 types of ventilation, depending on the type of unit: ON / OFF 3 speed modes For any further clarification regarding the type of ventilation refer to the unit electrical diagram. M22740C6-04 01/10/07 page 27 COOLING HEATING The ventilation is activated if: T H2O < P02 Maxh2oCool type of ventilation If the temperature is out of these limits when the delay time is finished, the H2O alarm is activated T H2O < T ambiente T H2O > P03 MinH2Oheat If the temperature is out of these limits when the delay time is finished, the H2O alarm is activated 3V 3V 2V 2V 1V 1V 3 speed Sizes 31÷71 p01 = BandaLavoro p01 = BandaLavoro Set-point Set-point WATER VALVE The system can control 2 ON-OFF valves, one for heat and the other for cold; they are connected to the basic module. The valve is opened when the thermo-regulator asks for power. Type of valve COOLING HEATING % valve % valve ON 0 – 10 v ON T amb. °C T amb. °C 0% 0% p01 = BandaLavoro p01 = BandaLavoro OFF OFF Set-point Set-point FRESH AIR DAMPER By using the proper dedicated output, it is possible to activate a damper or a fan to allow new air to enter the room. M22740C6-04 01/10/07 page 28 ELECTRIC RESISTANCES The electric resistance operating mode is defined by the following parameters: P27 ModeRes = 0 integration element (ventilation forced at max.) 1 main element (manual or automatic ventilation) P53 OutResType = 1 single-phase 2 two-phase 3 0 – 10 volt ON INTEGRATION OFF P01 Set Point P01 The water valve is opened when thermoregulation is demanded: if the probe detects hot water, the resistors automatically become an integration body. On the contrary, if after TimeValve is over, water temperature is not suitable, the valve closes, the H2O alarm is not activated and the resistors are not activated. As soon as the probe detects that water temperature > MinH2oHeat, resistors become integration bodies and the valve opens. In this mode, the water temperature alarm is not managed. ON MAIN ELEMENT OFF P01 Set Point ON SINGLE-PHASE RESISTANCES OFF P01 Set Point TWO-PHASE RESISTANCES P01 Set Point DEHUMIDIFICATION The dehumidification control is managed by the network, which is an upwards system that uses one or more terminal units to dehumidify. When the DeumiOn network variable is switched on 1, the unit is forced into cooling mode, even when the temperature set is met (100% opened valve and minimum ventilation speed). This occurs to meet the humidity conditions decided by the network (detecting the relevant humidity by a room thermostat). The dehumidification process shown by the display is stopped when the following occurs: • the DeumiOn variable is 0 (humidity conditions are met). • Temperature is below the LowLimit, value; therefore, the process can start again only if ambient temperature > setpoint Temp and if there is still a demand. The dehumidification process can not start if: • The operation mode is the Heating mode. • The unit is OFF. CONTROL (FOR UNITS WITH 3 SPEED BOARD) See ELECTRICAL CONNECTIONS section+ M22740C6-04 01/10/07 page 29 ROUTINE MAINTENANCE BEFORE UNDERTAKING ANY SORT OF MAINTENANCE OR CLEANING, DISCONNECT THE ELECTRICAL POWER SUPPLY TO THE UNIT, AND ENSURE THAT OTHER PEOPLE CANNOT RE-CONNECT IT . All equipment is subjected to wear out. cleaning activities; otherwise, controls have to be performed by specialized technicians (INSPECTIONS). The maintenance makes : 1. keeps the unit efficiency 2. the components last longer 3. keeps their efficiency and limits breakdowns Therefore, it is fundamental to perform periodical checks: a few controls can be performed by the user (AUTONOMOUS MAINTENANCE) and they are mainly The machine should have a log book used to keep track of the performed controls. This will make fixing up breakdowns easier. Take note of the date, type of control (autonomous maintenance, inspection or fixing up), description of the control, actions taken and so on. SERVICES Parts subject to intervention: • • • • • AIR FILTERS ROOM AIR TREATMENT COIL STRUCTURE ELECTRIC FANS DUCTING AIR FILTERS It is very important for the air treatment coil to be able to How often the filters need to be checked depends on the offer maximum thermal exchange. Therefore, the unit must quality of outdoor air, unit operating hours, dust and always operate with the filters installed and clean. number of persons in the rooms. As a guideline, cleaning should ideally take place between Cleaning and replacement of filters are very important in weekly and monthly. It is advisable to start with frequent terms of health and hygiene. checks, and to adjust the frequency based on how much Operation with clogged filters leads to a reduction in the air dirt is discovered. flow rate, resulting in malfunctions and unit shutdowns. It may even cause the unit to break down. PLEATED FILTERS Remove the closing doors Carefully extract the filter so that no dust reaches the parts below 3. Wash the filtering mattress in warm water with a common detergent. 4. Carefully rinse it under water while preventing to pour water in the room 5. Dry the filter 6. Reinsert it to its seat 7. Reassemble the closing doors Old filters, washing residuals and residual parts must be disposed of, according to the law in force. 1. 2. CONDENSATE DISCHARGE Dust and deposits could cause obstructions. Clean the tank, pour some water into the tank and check water flows normally. M22740C6-04 01/10/07 page 30 ROOM AIR TREATMENT COIL ATTENTION: accidental contact with the fins of the organisms and moulds most easily flourish. It is therefore exchanger may cause small cuts. When performing the very important to clean regularly with suitable detergents following steps, use protective gloves. and disinfect with appropriate products as necessary. The finned surfaces of the cooling coils and especially the condensation collection trays are the places where microSTRUCTURE Check the condition of the parts making up the structure. Paint so as to eliminate or reduce oxidation at the points in the unit where this problem may occur. Check that the panelling is fastened correctly. Poor fastening may give rise to malfunctions and abnormal noise and vibration. M22740C6-04 01/10/07 page 31 DUCTING Check the fixing screws and the operation of the anti-vibration devices in order to prevent the transmission of vibrations in the room. ELECTRIC FANS Make sure that the fans and the relative protection grids are well fixed. Check, if possible, the unbalances of the electro-fan evident by noise and anomalous vibrations. Verify that the terminal protection covers are closed and the cable holders are properly positioned. ELECTRICAL HEATING ELEMENTS The convector finned heating elements need to be checked regularly to ensure that they are clean and properly fastened to the support. MAINTENANCE INSPECTIONS Foresee inspection assistance carried out by authorized centers or by qualified personnel. The inspections should be carried out at least: • - Every year for only the cooling units • - Every six months for the cooling and warming units The frequency, however, depends on the use: in the event of frequent use (continuous or very intermittent use, near the operating limits, etc) or critical use (service necessary) it is recommended to plan inspections at close intervals. The inspections to be performed are as follows: • verify the power supply tension (when emptied or filled) • inspect the electrical board (status of solenoid starter contacts, terminal closings, the status of wiring and relevant insulations) • inspect the absorption of the single electrical loads • verify the leakage from the refrigerating circuit • Verify the protection devices (safety valves, pressure switches, thermostats, etc.), the adjustment systems, the control devices (alarm signalizations, probes, manometers, etc) • check the operating parameters of the refrigerating circuit (see the following REFRIGERANT TABLES and the START-UP section) For units equipped with safety valves, follow the Manufacturer’s instructions. Verify periodically the cleaning of the safety valves and that oxidative / corrosive phenomena are not present, in particular for installations near the sea, in industrial areas or in rooms with a corrosive atmosphere • verify the cleaning and the efficiency of the exchangers • inspect the cleaning of the filters (air/water) PUT AT REST If a long period of inactivity is foreseen, for example the winter for the cooling unit, the following is recommended: • to turn the power off in order to avoid electrical risks or damages by lightning strike • to avoid the risk of frosts as shown in the HYDRAULIC CONNECTIONS section, and, in particular - to empty or add glycole in the plant sections subjected to temperatures below zero - to empty or add glycole in the water heating coils, also in summer - to power antifreeze resistances if present M22740C6-04 01/10/07 If the period of inactivity is particularly long or in the event of extremely low temperatures, the external fans can be blocked temporarily; therefore, it is recommended to switch them on every month in order to avoid seizures or electrical overloads when the unit will be switched on. The restarting of the unit has to be carried out by qualified personnel, in particular, after the winter break for cooling units or when seasonal switching should be performed. When restarting, refer to the SWITCHING ON section. Schedule technical assistance in advance to avoid hitches and be able to use the installation when necessary. page 32 TROUBLESHOOTING THE OPERATIONS MUST BE CARRIED OUT BY TECHNICAL QUALIFIED PERSONNEL HAVING THE REQUISITES UNDER LAW REQUISITES AND IN CONFORMITY WITH THE SAFETY REGULATIONS IN FORCE. THE INTERVENTIONS WITHIN THE WARRANTY PERIOD WILL BE CARRIED OUT BY AUTHORIZED SERVICE CENTERS. BEFORE RESETTING AN ALARM, IDENTIFY AND ELIMINATE ITS CAUSE. REPEATED RESETS MAY CAUSE SERIOUS DAMAGES. In certain machine configurations, some safeties may be placed in series and lead back to a single input on the electronic module. Therefore, check on the electrical diagram whether the device to which the alarm corresponds has other devices or safeties connected in series. M22740C6-04 01/10/07 page 33 DECOMMISSIONING OF THE UNIT DISCONNECTING THE UNIT The units must be disconnected by authorised personnel, who before proceeding must first read the Residual Risks section in this manual. Before disconnecting the unit, the following must be recovered, if present: • • the refrigerant (if the circuits cannot be isolated): the refrigerant must be removed using suction devices operating in a closed circuit, so as to ensure that none of the compound is released into the atmosphere. the antifreeze in the circuits: when removing this fluid, make sure that it does not leak and that it is not released into the environment. The antifreeze fluid must be stored in special containers. When recovering the substances present in the unit, all measures must be taken to avoid damaging persons and things and polluting the surrounding area. M22740C6-04 01/10/07 Awaiting dismantling and disposal, the unit can also be stored outdoors, as bad weather and rapid changes in temperature will not cause damage to the environment, if electric, cooling and hydraulic circuits of the unit are integral and closed. DISMANTLING AND DISPOSAL THE UNIT MUST ALWAYS BE SENT TO AUTHORISED CENTRES FOR DISMANTLING AND DISPOSAL. When dismantling the unit, the fan, the motor and the coil, if operating, may be recovered by the specialist centres for reuse. All the materials must be recovered or disposed of in compliance with the corresponding national standards in force. For further information on the decommissioning of the unit, contact the manufacturer. page 34 TECHNICAL DATA Sizes COOLING Cooling capacity 1 kW Sensible capacity 1 kW Total power input 1 kW HEATING Heat output 2 kW INTERNAL EXCHANGER 2 Front surface m Number of rows Water content l Water flow-rate l/s AIR HANDLING SECTION FANS (SUPPLY) Type of fans 3 Air flow 4 l/s Max outside static pressure 5 Pa CONNECTIONS Water fittings Condensate discharge mm DIMENSIONS Length mm Depth mm Height mm STANDARD UNIT WEIGHTS Shipping weight kg 25 31 41 51 71 8,70 6,69 0,47 12,7 9,71 0,61 15,2 11,2 0,61 18,7 14,3 0,75 21,6 16,6 1,43 20,2 29,3 33,4 43,1 50 0,24 4 2,86 0,42 0,29 4 3,45 0,61 0,36 4 4,25 0,73 0,42 4 4,96 0,90 0,48 4 5,67 1,03 502 130 708 140 CFG 738 150 1031 230 1237 250 ¾” 1” 35 1000 480 297 1100 500 322 1340 550 322 1340 550 372 1340 550 422 38 45 50 60 71 (1) nominal air flow Ambient temperature 27°C/19.5 WB water return 7°C and supply 12°C (2) nominal air flow ambient temperature 20°C DB water return 70°C and supply 60°C (3) CFG = centrifugal fan (4) Max outside static pressure (5) rated flow, maximum speed, including the air filter OPERATING LIMITS Sizes INTERNAL EXCHANGER Max. water return temperature Min. air temperature return (D.B.) Max. air temperature return (D.B.) Min. water return temperature Maximum water side pressure 25 31 °C °C °C °C bar 41 51 71 80 2 40 2 16 DB = dry bulb WB = wet bulb M22740C6-04 01/10/07 page 35 SOUND LEVELS FAN SPEED: Low speed (L) Sound Power Level (dB) Size 63 67 66 67 68 68 25 31 41 51 71 125 73 70 66 66 68 250 61 62 63 61 63 Octave band (Hz) 500 1000 2000 4000 8000 56 53 45 38 29 58 54 49 43 36 58 56 53 46 37 59 55 54 48 40 59 56 55 50 44 Sound pressure level dB(A) 47 47 48 48 49 Sound power level dB(A) 60 61 61 62 63 Sound pressure level dB(A) 51 52 53 54 54 Sound power level dB(A) 65 66 67 68 68 Sound pressure level dB(A) 54 55 56 57 58 Sound power level dB(A) 67 68 69 71 72 The sound levels refer to the unit with standard installation, ducted supply and intake for 1,5 m, air not going to the test ambient and fans at min, medium and max speed. Sound pressure level measured at distance 1 m from the external unit surface. FAN SPEED: Medium speed (M) Sound Power Level (dB) Size 63 72 71 74 72 75 25 31 41 51 71 125 77 71 75 74 75 250 67 66 68 68 68 Octave band (Hz) 500 1000 2000 4000 8000 62 57 50 44 34 63 61 56 48 38 63 59 57 51 40 64 61 60 55 43 65 62 59 53 45 FAN SPEED: High speed (H) Sound Power Level (dB) Size 63 74 73 76 75 78 25 31 41 51 71 125 79 76 74 75 79 250 70 72 72 73 73 Octave band (Hz) 500 1000 2000 4000 8000 65 59 52 47 38 67 59 53 51 41 68 62 58 53 43 68 66 62 58 42 69 67 63 58 47 INTERNAL EXCHANGER PRESSURE DROP 24 25 22 20 18 DP (KPa) 16 71 31 14 41 12 51 10 8 6 4 2 0 (l/s) (m³/h) 0 0 0.25 0.9 0.50 1.8 0.75 2.7 1.00 3.6 1.25 4.5 Q Q = WATER FLOW M22740C6-04 DP = PRESSURE DROP 01/10/07 page 36 DIMENSIONS B 75 I 2 O D 100 7 30 E C L 20 1 20 25 4 3 50 5 A 50 F 100 25 6 40 N 30 M 8 G H (1) WATER SUPPLY (STANDARD UNIT) (2) WATER RETURN (STANDARD UNIT) (3) DRAIN STUB (4) FAN ACCESS PANEL (5) FILTER REMOVAL DOOR (6) AIR FILTER (7) ELECTRICAL PANEL (8) HOLE TO HANG UNIT Size A B C 25 1000 480 297 31 1100 500 322 41 1340 550 322 51 1340 550 372 71 1340 550 422 Note: Dimensions are in mm. M22740C6-04 D 210 235 235 285 335 E 235 235 260 260 260 DIMENSIONS F G 860 800 960 800 1200 1060 1200 1060 1200 1060 01/10/07 H 160 210 200 200 200 I 1055 1155 1395 1395 1395 L 90 125 125 175 175 M 305 350 350 350 350 N 85 65 95 95 95 O 135 155 155 155 155 page 37 M22740C6-04 01/10/07 page 38 CLIVET SPA Feltre (BL) ITALY Tel. + 39 0439 3131 Fax + 39 0439 313300 info@clivet.it CLIVET ESPAÑA S.A. (Madrid) SPAIN Tel. + 34 91 6658280 Fax + 34 91 6657806 info@clivet.es CLIVET UK LTD Fareham (Hampshire) U.K. Tel. + 44 (0) 1489 572238 Fax + 44 (0) 1489 573033 info@clivet-uk.co.uk CLIVET NEDERLAND B.V. Amersfoort - Netherlands Tel. + 31 (0) 33 7503420 Fax + 31 (0) 33 7503424 info@clivet.nl CLIVET TFA (PVT) LTD Bangalore - INDIA Tel. + 91 80 25351617 Fax + 91 80 25351392 sales@clivettfa.com The data contained in this bulletin is not binding and may be changed by the manufacturer without prior notice. All reproduction, even partial, is PROHIBITED. © COPYRIGHT - CLIVET S.P.A. - FELTRE (BL) - ITALIA