1. General
3. Fixture Installation
1.1The Windsor Series Fixture is designed to accept most of
the standard low wattage, medium and mogul-base HID
lamps currently available.
3.1Disconnect all electrical power to the Fixture’s mounting
location.
1.2The Fixture includes an Electrical Module that contains a
twistlock photocell or photocell receptacle when specified.
These Modules are common to all luminaire styles in this
Series.
1.3Each assembly is shipped complete in one carton.
! WARNING
READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL OR MAINTAIN THIS
PRODUCT. WORK MUST BE DONE BY QUALIFIED
PERSONNEL.
IMPROPER INSTALLATION OR
MAINTENANCE MAY RESULT IN INJURY OR DEATH
OR SIGNIFICANT PROPERTY DAMAGE.
BE CERTAIN THAT ALL ELECTRICAL POWER IS
DISCONNECTED FROM THE FIXTURE BEFORE
INSTALLING OR MAINTAINING THE FIXTURE.
FAILURE TO DO SO MAY RESULT IN INJURY OR
DEATH.
Description
Slotted (flat) Screwdriver
5/32 Allen Wrench
3/16 Allen Wrench
3.3Set the Fixture on its mount. Orient and plumb the Fixture
before tightening set screws. The Fixture should be oriented
so that the photocell, or the opening in which the photocell
receptacle is located, is pointed in a Northern direction.
3.4Alternately tighten all 6 set screws to level and secure the
Fixture.
4. Field Wiring & Photocell Installation
4.1Access to the Photocell, Lamp, and Electrical Module is
achieved by loosening the single retaining screw under the
Covers edge opposite the hinge. Note the Retaining screw is
captive and will not fall out. Tilt the Cover Assembly back.
A cable or hinge stop is provided to support the Cover in the
open position. It is recommended that the Cover be opened
slowly until held by the tension of the cable.
4.2If Fixture is equipped with a Finial it will be shipped upside
down inside the Fixture Cover. Remove Finial and install on
cover using existing hardware (Fig. 3).
2. Tools and Material Required
3.2Loosen set screws in Slipfitter to allow the Slipfitter base to
slide over the mount (pole-top, tenon or bracket). (Fig. 1)
Use
Connecting electrical power to Module
Attaching Fixture to Pole
Loosening and tightening Cover
4.3Connect incoming electrical power conductor(s) to proper
wiring locations as marked on the Field Wiring Label (Fig
2.).
4.4If required, a twistlock receptable will be installed. Place
Photocell into receptacle and twist firmly clockwise. This
will align the photocell window with the window in the fixture
base (Fig. 2).
Finial
Lamp
Cover
Assembly
Name Plate
& Field
Wiring
Labels
Lens
(6 ea.)
Retaining
Screw
Slipfitter
Set Screws
(6 ea.)
Cover
Gasket
Gasket
Washer
Lock
Washer
Bolt
Photocell
Receptacle
Photocell
Figure 2
Figure 3
Figure 1
5. Lamp Installation
5.1Install the proper Lamp type in the lamp Socket being careful
to verify that the Lamp type and wattage are correct for
the Fixture installed (see name plate on neck of electrical
Module). (Fig. 2)
5.2Power the Fixture and check for proper operation, including
operation with the Photocell, if installed.
6.5Install the proper Lamp type and wattage in the lamp
Socket after verifying Lamp type and wattage for the
Fixture installed (see name plate on neck of electrical
module). (Fig. 2)
6.6Close Cover and retaining screw (Fig. 1 & 4.1).
6.7Power the Fixture and check for proper operation.
6. Maintenance:
Relamping and Cleaning
6.1Disconnect all electrical power to the Pole and Lighting
Fixture. Wipe off any exterior dirt and debris from Lens
and Fixture.
6.2Loosen retaining screw in Cover (Fig. 1& 4.1). Globe.
6.3Remove the Lamp and dispose of in a safe and proper
manner.
6.4Wipe off Lens with a dry cloth. If Lens need to be
washed, use water and mild detergent.