SLM Use Installation Programming Communication K

advertisement
K-TRON SODER Product Specification
Smart Lopo Module (controller)
A
D
A
B
C
D
C
B
Ext. communication to the host system
Feeder
Weighing system
Smart Lopo Module (SLM)
Operator Interface
SLM
Each K-TRON SODER weigh feeder
is composed of components A, B, C and D.
This specification describes component C.
Use
The Smart Lopo Module (SLM) serves the purpose of operating, regulating and controlling a
single K-TRON SODER weigh feeder under the following conditions:
- DC motor
- Motor power 180 W max.; 180 to 200 V DC
- Single point weighing system or weigh bridge
The SLM was developed for the K2G and K-CL-24-KT20 weigh feeders without a separate
agitator
External operating panel with
housing
In addition, the control for a K-TRON Hurricane refill device is integrated.
Installation
The control module SLM is always installed in a housing at the feeder. The operating panel may
either be placed in the same housing or in a separate housing which can be attached or builtin anywhere as desired. Up to a distance of 10 m it may be powered by the controller; in the case
of distances up to 500 m by an external 24 V power supply.
Given in the three figures are three possible configurations:
- External housing with the operating panel
- SLM with operating panel at a K2G feeder
- SLM with operating panel at a K-CL-24-KT20 feeder
SLM for K2G feeders with
operating panel
Programming
The initial settings (equipment and process data) are entered into the controller only once during
initial programming.
All entries are made through the easy to operate key pad. The data may be displayed any time
through the display.
SLM for a K-CL-24-KT20 feeder
with operating panel
Communication
Host
Host
Modbus/ Allen Bradley/3964R
Modbus
LON
KSL
K10S Protocol/RS485
SLM
SLM
Feeder
Rev.
03.2002
CD06
ISO#
Doc #
replaces:
Feeder
0290020305
07.08-2031, 08.08-2031
SCM with
SmartLink
board
Feeder
SCM
Feeder
S-070205-en
Page 1 of 2
K-TRON SODER Product Specification
Smart Lopo Module (controller)
SLM
Operation
The operation is very simple. The data entry is accomplished
with keys, which are marked with easily recognizable symbols.
This data, as well as the resulting operation data, are filed in a
sort of index. They can be leafed through and looked at with the
Next Key.
Signal lamps
LCD-display
(4 bands)
Key touchpad for
entering and
programming
Symbol Keys
GRAV/VOL operation shift
Home to operation level
Escape from points in menu or levels
Changes in programming level
Film keyboard
Leafing through screens
Enter setpoint
Processing of total value
Alarm
Start
Stop
Enter
GRAV LOCAL REFILL LWF
Setpoint
0.000 lb/hr
Massflow
0.000 lb/hr
Net weight
0.000 lb
Speed
0.000 rpm
Drive command
0.000 %
Feed factor
0.000
Totaliser
0.000 lb
Power supply
Actual values
Process
characteristics
Signal Lamps
Start
Stop
Alarm
Program level
Environmental conditions
Voltage:
Frequency:
Max. power consumption:
External operating panel:
115 V AC ±10% or
230 V AC ±15%
50-60 Hz
220 W
14-40 VDC/12-29 VAC
2.2 W
Zone classifications:
Ambient temperature range:
Storage temperature range:
Max. humidity:
Protection:
General applications
0° C (32° F) up to 50° C (122° F)
-30° C (-86° F) up to 80° C (176° F)
95% at 35° C (95° F) non-condensing
IP 55
Output specifications
Electrical standards
Electromagnetic radiation:
Electromagnetic interference
immunity:
Electrical safety:
EN50081-2
EN50082-2
EN 61010-1
Output power:
Motor voltage:
Control range:
Outputs:
Inputs:
Max. 180 W
180 - 200 V=
100:1
2 Relays, 4 Bit
6 Bit, 1 Analog 0-20/4-20 mA/0-10V
Approvals
USA und Canada:
Europe:
National Code
CE
118 (46.5)
144.5 (56.9)
Dimensional diagram [mm (in)], external operating panel
30 (11.8)
118 (46.5)
K-TRON AMERICA
Routes 55 & 553
Pitman, NJ 08071 USA
Tel: (856) 589-0500
Fax: (856) 589-8113
e-mail: ka@ktron.com
144.5 (56.9)
K-TRON (Schweiz) AG
Industrie Lenzhard
CH-5702 Niederlenz
Tel: (062) 885 71 71
Fax: (062) 885 71 80
e-mail ks@ktron.com
Internet: www.ktron.com
Copyright by K-TRON. Covered by patents in USA and foreign countries. Specifications subject to change without notice.
85 (33.5)
For the addresses of all
K-TRON Companies
see info sheet I-000001
Rev. 0
CD06
S-070205-en
Page 2 of 2